TurboCharger™ Flueing Specifications

Models:

37-225CE 44-380CE 59-380CE 73-380CE 88-380CE

117-380CE

Lochinvar Limited 7 Lombard Way The MXL Centre

Banbury Oxon

OX16 4TJ

Tel: +44 (0)1295 269981 Fax: +44 (0)1295 271640

Email: [email protected]

Issue 1C November 08

www.lochinvar.ltd.uk

Page 2: TurboCharger - sbs Specifications... · TurboCharger ™ Flueing ... INSTMAN Turbo Charger Installation Manual 1 M87887 Concentric flue pipe with sample points - 100/150mm dia. M87897
Page 3: TurboCharger - sbs Specifications... · TurboCharger ™ Flueing ... INSTMAN Turbo Charger Installation Manual 1 M87887 Concentric flue pipe with sample points - 100/150mm dia. M87897

1

INDEX Horizontal Concentric Balanced Flue Model 35-225CE…………………………….…………………………………..2 Models 44-380CE, 59-380CE, 73-380CE, 88-380CE and 117-380CE..…...3 Vertical Concentric Balanced Flue Model 35-225CE…………………………….…………………………………..4 Models 44-380CE, 59-380CE, 73-380CE, 88-380CE and 117-380CE..…...5 Horizontal Conventional Flue Models 44-380CE, 59-380CE, 73-380CE, 88-380CE and 117-380CE….…6 Vertical Conventional Flue Models 44-380CE, 59-380CE, 73-380CE, 88-380CE and 117-380CE…....7

Concentric Balanced Flue Standard Spec Component Assembly ……………….8 Notes…………………………………………………………………………………….9 Concentric Flue Options With flue runs in excess of 5M we recommend that a condensate trap (M87897) be installed.

Page 4: TurboCharger - sbs Specifications... · TurboCharger ™ Flueing ... INSTMAN Turbo Charger Installation Manual 1 M87887 Concentric flue pipe with sample points - 100/150mm dia. M87897

2

FLUE SPECIFICATION HORIZONTAL CONCENTRIC BALANCED FLUE

TURBOCHARGER MODEL

37-225CE

PART NO: TCHF001 - HORIZONTAL FLUE KIT

Maximum Equivalent Flue Length = 16.0 Metres

Deduct 1.2 metre for each 90° Bend Deduct 0.7 metre for each 45° Bend

Each Horizontal Flue Kit Includes all items marked as Std Spec

Part No Description Std Spec M82500 Exhaust outlet lower tee piece - 100mm dia. 1 M75412 Exhaust connector tube - 100mm dia. (225 litre) 1 M82501 Air intake upper tee piece - 100mm dia. 1 M87436 Condensate syphon (lower tee piece) 1 M87990 Flue terminal - horizontal - 100/150mm dia. 1 M87890 90° Concentric bend c/w clamp - 100/150mm dia. 1 M87832 1000mm Concentric flue pipe (cutable) - 100/150mm dia. 1

INSTMAN Turbo Charger Installation Manual 1

M87887 Concentric flue pipe with sample points - 100/150mm dia. M87897 Horizontal/Vertical condense trap - 100/150mm dia. M87491 Condensate drain pipework & elbows M87436 Condensate syphon M87882 500mm Concentric flue pipe - 100/150mm dia. M87883 1000mm Concentric flue pipe - 100/150mm dia. M87884 2000mm Concentric flue pipe - 100/150mm dia. M87886 500mm Concentric flue pipe (cutable) - 100/150mm dia. M87832 1000mm Concentric flue pipe (cutable) - 100/150mm dia. M87891 43°- 45° Concentric bend c/w clamp - 100/150mm dia. M87890 90° Concentric bend c/w clamp - 100/150mm dia.

Page 5: TurboCharger - sbs Specifications... · TurboCharger ™ Flueing ... INSTMAN Turbo Charger Installation Manual 1 M87887 Concentric flue pipe with sample points - 100/150mm dia. M87897

3

FLUE SPECIFICATION HORIZONTAL CONCENTRIC BALANCED FLUE

TURBOCHARGER MODELS

44-380CE, 59-380CE, 73-380CE, 88-380CE, 117-380CE

PART NO: TCHF002 - HORIZONTAL FLUE KIT

Maximum Equivalent Flue Length = 16.0 Metres

Deduct 1.2 metre for each 90° Bend Deduct 0.7 metre for each 45° Bend

Each Horizontal Flue Kit Includes all items marked as Std Spec

Part No Description Std Spec M82500 Exhaust outlet lower tee piece - 100mm dia. 1 M75413 Exhaust connector tube - 100mm dia. (380 litre) 1 M82501 Air intake upper tee piece - 100mm dia. 1 M87436 Condensate syphon (lower tee piece) 1 M87990 Flue terminal - horizontal - 100/150mm dia. 1 M87890 90° Concentric bend c/w clamp - 100/150mm dia. 1 M87832 1000mm Concentric flue pipe (cutable) - 100/150mm dia. 1

INSTMAN Turbo Charger Installation Manual 1

M87887 Concentric flue pipe with sample points - 100/150mm dia. M87897 Horizontal/Vertical condense trap - 100/150mm dia. M87491 Condensate drain pipework & elbows M87436 Condensate syphon M87882 500mm Concentric flue pipe - 100/150mm dia. M87883 1000mm Concentric flue pipe - 100/150mm dia. M87884 2000mm Concentric flue pipe - 100/150mm dia. M87886 500mm Concentric flue pipe (cutable) - 100/150mm dia. M87832 1000mm Concentric flue pipe (cutable) - 100/150mm dia. M87891 43°- 45° Concentric bend c/w clamp - 100/150mm dia. M87890 90° Concentric bend c/w clamp - 100/150mm dia.

Page 6: TurboCharger - sbs Specifications... · TurboCharger ™ Flueing ... INSTMAN Turbo Charger Installation Manual 1 M87887 Concentric flue pipe with sample points - 100/150mm dia. M87897

4

FLUE SPECIFICATION VERTICAL CONCENTRIC BALANCED FLUE

TURBOCHARGER MODEL

37-225CE

PART NO: TCVF001 - FLUE KIT

Maximum Equivalent Flue Length = 16.0 Metres

Deduct 1.2 metre for each 90° Bend Deduct 0.7 metre for each 45° Bend

Each Vertical Flue Kit Includes all items marked as Std Spec

Note : Vertical Terminals require flashing

Part No Description Std Spec M82500 Exhaust outlet lower tee piece - 100mm dia. 1 M75412 Exhaust connector tube - 100mm dia. (225 litre) 1 M82501 Air intake upper tee piece - 100mm dia. 1 M87436 Condensate syphon (lower tee piece) 1 M87969 Flue terminal - vertical condensing - 100/150mm dia. 1

INSTMAN Turbo Charger Installation Manual 1

M87887 Concentric flue pipe with sample points - 100/150mm dia. M87897 Horizontal/Vertical condense trap - 100/150mm dia. M87491 Condensate drain pipework & elbows M87436 Condensate syphon M87379 Flat Roof Flashing – 100/150mm dia. M87882 500mm Concentric flue pipe - 100/150mm dia. M87883 1000mm Concentric flue pipe - 100/150mm dia. M87884 2000mm Concentric flue pipe - 100/150mm dia. M87886 500mm Concentric flue pipe (cutable) - 100/150mm dia. M87832 1000mm Concentric flue pipe (cutable) - 100/150mm dia. M87891 43°- 45° Concentric bend c/w clamp - 100/150mm dia. M87890 90° Concentric bend c/w clamp - 100/150mm dia.

Page 7: TurboCharger - sbs Specifications... · TurboCharger ™ Flueing ... INSTMAN Turbo Charger Installation Manual 1 M87887 Concentric flue pipe with sample points - 100/150mm dia. M87897

5

FLUE SPECIFICATION VERTICAL CONCENTRIC BALANCED FLUE

TURBOCHARGER MODELS

44-380CE, 59-380CE, 73-380CE, 88-380CE, 117-380CE

PART NO: TCVF002 - HORIZONTAL FLUE KIT

Maximum Equivalent Flue Length = 16.0 Metres

Deduct 1.2 metre for each 90° Bend Deduct 0.7 metre for each 45° Bend

Each Vertical Flue Kit Includes all items marked as Std Spec

Note : Vertical Terminals require flashing

Part No Description Std Spec M82500 Exhaust outlet lower tee piece - 100mm dia. 1 M75413 Exhaust connector tube - 100mm dia. (380 litre) 1 M82501 Air intake upper tee piece - 100mm dia. 1 M87436 Condensate syphon (lower tee piece) 1 M87969 Flue terminal - vertical condensing - 100/150mm dia. 1

INSTMAN Turbo Charger Installation Manual 1

M87887 Concentric flue pipe with sample points - 100/150mm dia. M87897 Horizontal/Vertical condense trap - 100/150mm dia. M87491 Condensate drain pipework & elbows M87436 Condensate syphon M87379 Flat Roof Flashing – 100/150mm dia. M87882 500mm Concentric flue pipe - 100/150mm dia. M87883 1000mm Concentric flue pipe - 100/150mm dia. M87884 2000mm Concentric flue pipe - 100/150mm dia. M87886 500mm Concentric flue pipe (cutable) - 100/150mm dia. M87832 1000mm Concentric flue pipe (cutable) - 100/150mm dia. M87891 43°- 45° Concentric bend c/w clamp - 100/150mm dia. M87890 90° Concentric bend c/w clamp - 100/150mm dia.

Page 8: TurboCharger - sbs Specifications... · TurboCharger ™ Flueing ... INSTMAN Turbo Charger Installation Manual 1 M87887 Concentric flue pipe with sample points - 100/150mm dia. M87897

6

FLUE SPECIFICATION

HORIZONTAL CONVENTIONAL FLUE

TURBOCHARGER MODELS 37-225CE, 44-380CE, 59-380CE, 73-380CE, 88-380CE and

117-380CE

PART NO: TCFC001 – CONVENTIONAL FLUE KIT

Maximum Equivalent Flue Length = 33.0 Metres

Deduct 1.2 metre for each 90° Bend Deduct 0.7 metre for each 45° Bend

Each Horizontal Conventional Flue Kit Includes all items marked as Std Spec

Part No Description Std Spec M82500 Exhaust outlet lower tee piece - 100mm dia. 1 M82501 Air intake upper tee piece - 100mm dia. 1 M87436 Condensate syphon (lower tee piece) 1

01-513-36-07 100mm Stainless steel grid (air from plantroom) 1 01-513-36-07 100mm Stainless steel grid (flue terminal end) 1 01-513-36-08 100mm Wall cover plate (white) 1

INSTMAN Turbo Charger Installation Manual 1

01-513-01-20 100mm dia. x 1000mm Stainless steel flue extension 01-513-01-10 100mm dia. x 500mm Stainless steel flue extension 01-513-01-03 100mm dia. 90 deg. Stainless steel elbow 01-513-01-04 100mm dia. 45 deg. Stainless steel elbow 01-513-01-06 100mm dia. Condense drain & siphon kit

Page 9: TurboCharger - sbs Specifications... · TurboCharger ™ Flueing ... INSTMAN Turbo Charger Installation Manual 1 M87887 Concentric flue pipe with sample points - 100/150mm dia. M87897

7

FLUE SPECIFICATION

VERTICAL CONVENTIONAL FLUE

TURBOCHARGER MODELS 37-225CE, 44-380CE, 59-380CE, 73-380CE, 88-380CE and

117-380CE

PART NO: TCFC002 – CONVENTIONAL FLUE KIT

Maximum Equivalent Flue Length = 33.0 Metres

Deduct 1.2 metre for each 90° Bend Deduct 0.7 metre for each 45° Bend

Each Vertical Conventional Flue Kit Includes all items marked as Std Spec

Note : Vertical Terminals require flashing

Part No Description Std Spec M82500 Exhaust outlet lower tee piece - 100mm dia. 1 M82501 Air intake upper tee piece - 100mm dia. 1 M87436 Condensate syphon (lower tee piece) 1

01-513-36-07 100mm Stainless steel grid (air from plantroom) 1 01-513-36-02 100mm dia. Vertical flue terminal (Trega Cap) 1

INSTMAN Turbo Charger Installation Manual 1

01-513-01-20 100mm dia. x 1000mm Stainless steel flue extension 01-513-01-10 100mm dia. x 500mm Stainless steel flue extension 01-513-01-03 100mm dia. 90 deg. Stainless steel elbow 01-513-01-04 100mm dia. 45 deg. Stainless steel elbow 01-513-01-06 100mm dia. Condense drain & siphon kit

Page 10: TurboCharger - sbs Specifications... · TurboCharger ™ Flueing ... INSTMAN Turbo Charger Installation Manual 1 M87887 Concentric flue pipe with sample points - 100/150mm dia. M87897

8

Concentric Balanced Flue Standard Spec Component Assembly

Note: All TurboCharger models require siting on an elevated base of 200mm minimum. A prefabricated elevated base is available from Lochinvar Limited as an optional ancillary - part number: TC9001.

M75412 (225 litre)M75413 (380 litre)

M82500

M82501

M87436

R.H. SIDE VIEWFRONT VIEW

200mm Elevated base

Page 11: TurboCharger - sbs Specifications... · TurboCharger ™ Flueing ... INSTMAN Turbo Charger Installation Manual 1 M87887 Concentric flue pipe with sample points - 100/150mm dia. M87897

9

NOTES NOTES __________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

Page 12: TurboCharger - sbs Specifications... · TurboCharger ™ Flueing ... INSTMAN Turbo Charger Installation Manual 1 M87887 Concentric flue pipe with sample points - 100/150mm dia. M87897

Lochinvar Limited 7 Lombard Way The MXL Centre

Banbury Oxon

OX16 4TJ

Tel: +44 (0)1295 269981 Fax: +44 (0)1295 271640

Lochinvar Ltd has the right to change specifications without prior notice