UK83055500cUK – Translation of the original operating manual
Operating ManualHydraulic Module 2
Accessories fortwo Dual Air / Water Heat Pumps
HMD 2/(S)EHMD 2/R(S)E
2 Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
Please read firstThis operating manual provides important information on handling the unit. It is an integral part of the product and must be kept ready to hand in the immediate vicin-ity of the unit. It must remain available throughout the entire service life of the unit. It must be handed over to subsequent owners or users of the unit.
Read the operating manual before working on or op-erating the unit. This applies in particular to the chap-ter on safety. Always follow all instructions completely and without restrictions.
It is possible that this operating manual may contain instructions that seem incomprehensible or unclear. In the event of any questions or if any details are unclear, contact the factory customer service department or the manufacturer's local partner.
As this operating manual has been written for sever-al unit models, always comply with the parameters for the respective model.
This operating manual is intended only for persons as-signed to work on or with the unit. Treat all constituent parts confidentially. The information contained herein is protected by copyright. No part of this manual may be reproduced, transmitted, copied, stored in electron-ic data systems or translated into another language, either wholly or in part, without the express written permission of the manufacturer.
SymbolsThe following symbols are used in the operating man-ual. They have the following meaning:
Information for operators.
Information or instructions for qualified technicians.
DANGER Indicates a direct impending danger result
ing in severe injuries or death.
WARNING Indicates a potentially dangerous situa
tion that could result in serious injuries or death.
CAUTION Indicates a potentially dangerous situation
that could result in moderate or slight injuries.
ATTENTION Indicates a potentially dangerous situation,
which could result in property damage.
NOTE Emphasised information.
9 Prerequisite for an action.
► Single-step instruction for action.
1., 2., 3., … Numbered step within a multi-step in-struction for action. Adhere to the given se-quence.
● List.
Reference to further information elsewhere in the operating manual or in another docu-ment.
€ ENERGY SAVING TIP Indicates suggestions that help to save energy,
raw materials and costs.
3Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
ContentsPlease read first ........................................................ 2Symbols ..................................................................... 2Intended use .............................................................. 4Disclaimer .................................................................. 4Safety and Security ................................................... 4Contact ...................................................................... 5Warranty / Guarantee ................................................ 5Waste disposal .......................................................... 5Heat metering ............................................................ 5Operation ................................................................... 5Care of the unit .......................................................... 6Maintenance of the unit ............................................. 6Malfunctions .............................................................. 6Scope of supply ......................................................... 6
Components of the unit ........................................ 7Installation ................................................................. 8
Installation location ............................................... 8Transport to installation location .......................... 8Installation ............................................................ 8Unit lettering / labelling ......................................... 9Installation / Hydraulic connection
to heating circuit ............................................ 10Safety assembly ..................................................11Expansion vessels ..............................................11
Electrical connections ............................................. 12400 V / 230 V operation ..................................... 12Electrical connection of the heat pumps
to the hydraulic module ................................. 13Flushing, filling and bleeding the system ................. 15Insulating the hydraulic connections ....................... 15Set the overflow valve ............................................. 16Commissioning ........................................................ 16
Safety temperature limiter .................................. 16Dismantling .............................................................. 17
Technical data/Scope of supplyHMD 2/(S)E ........................................................ 18HMD 2/R(S)E ..................................................... 19
Free pressure .......................................................... 20Dimensioned drawings
HMD 2/(S)E ........................................................ 21HMD 2/R(S)E ..................................................... 22
Drilling pattern ......................................................... 23Installation plans
HMD 2/(S)E ........................................................ 24HMD 2/R(S)E ..................................................... 25
Pressure loss calculationsCalculation example ........................................... 26Calculation of your system ................................. 27
Flushing and venting processesFlushing and venting process, hot water circuit . 28Flushing and venting process, heating circuit .... 29Flushing and venting process, heat pump 1 ...... 30Flushing and venting process, heat pump 2 ...... 31
Hydraulic integrationRow tank ............................................................ 32Separate buffer tank and
unit variant R (cooling)................................... 33Legend Hydraulic integration.............................. 34
Schematic diagram of the electrical connections .... 36Terminal diagrams
400V: LWD … / HMD 2/… .................................. 37230V: LWD ... / HMD 2/… ................................... 38
Circuit diagrams ...................................................... 39EC declaration of conformity ................................... 43
4 Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
Intended useThe hydraulic module is a functionally relevant acces-sory for dual air/water heat pumps intended for out-door installation. Taking into account the limits of use, the unit can be used in conjunction with up to two dual air/water heat pumps installed outdoors in new or ex-isting heating systems.The unit must be used solely for its intended purpose. This means, in conjunction with a dual air/water heat pump:
● for heating. ● for cooling (reversible variant only). ● for water heating.
The unit may be operated only within its technical pa-rameters.
“Technical Data / Scope of Supply” overview from Page 18 and “Technical Data / Scope of Sup-ply” overview of the operating manual of the heat pump to which the hydraulic module is connected.
DisclaimerThe manufacturer is not liable for damage or losses resulting from any use of the unit which is not its in-tended use.
The manufacturer's liability also expires:
● if work is carried out on the unit and its compo-nents contrary to the instructions in this oper-ating manual.
● if work is carried out improperly on the unit and its components.
● if work is carried out on the unit which is not described in this operating manual, and this work has not been explicitly approved by the manufacturer in writing.
● if the unit or components in the unit have been altered, modified or removed without the ex-plicit written consent of the manufacturer.
Safety and SecurityThe unit is safe to operate for its intended use. The construction and design of the unit conform to current state-of-the-art standards, all relevant DIN/VDE regu-lations and all relevant safety regulations.
Every person who performs work on the unit must have read and understood the operating manual prior to starting any work. This also applies if the respective person has already worked with such a unit or a simi-lar unit or has been trained by the manufacturer.
Every person who performs work on the unit must comply with the applicable accident prevention and safety regulations. This applies in particular to the wearing of personal protective equipment.
DANGER Risk of fatal electric shock! All electrical connection work must be car
ried out by qualified electricians only. Before opening the unit, disconnect the
system from the power supply and prevent it from being switched back on!
WARNING Only qualified personnel (trained heating,
cooling engineers and electricians) may carry out work on the unit and its components.
WARNING Observe safety labels on and in the unit.
ATTENTION For safety reasons: Never disconnect the unit from the power sup-
ply system, unless the unit is being opened.
5Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
ContactAddresses for purchasing accessories, for servicing or for answers to questions about the unit and this operating manual can be found on the internet and are kept up-to-date:
● Germany: www.alpha-innotec.de
● EU: www.alpha-innotec.com
Warranty / GuaranteeFor warranty and guarantee conditions, please refer to the purchase documents.
NOTE Please contact your dealer about all matters
concerning warranties and guarantees.
Waste disposalWhen decommissioning the unit, always comply with applicable laws, directives and standards for the re-covery, recycling and disposal of materials and com-ponents.
“Dismantling”, Page 17
Heat meteringIn addition to proof of the unit's efficiency, the EEWaer-meG also requires heat metering (hereafter referred to as HQR). Heat metering is mandatory for air/water heat pumps. A WME (heat metering) only has to be installed for brine/water and water/water heat pumps for a flow temperature ≥35 °C. The WME must record the total thermal energy output (heating and hot water) in the building. In heat pumps with heat metering, the analysis is carried out by the regulator. The regulator displays the thermal energy discharged in the heating system in kWh.
OperationYour decision to purchase a heat pump or a heat pump system is a long-term contribution to protecting the en-vironment through low emissions and reduced prima-ry energy use.You can operate and control the heat pump system with the control element of the heating and heat pump regulator.
NOTE Make sure that the control settings are correct.
Operating manual of the heating and heat pump controller.
To ensure that your heat pump or heat pump system operates efficiently and ecologically, the following are especially important:
€ ENERGY SAVING TIP Avoid unnecessarily high flow temperatures. A lower flow temperature on the hot water side
increases the efficiency of the system.
€ ENERGY SAVING TIP Preferably use purge ventilation. Compared to
continuously open windows, it is better to air rooms by fully opening windows for a short pe-riod, two to three times a day (so-called “rapid” or “purge” ventilation); this reduces energy consumption and your heating bill.
6 Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
Care of the unitThe outer surfaces of the unit can be cleaned with a damp cloth and standard cleaning products.
Do not use cleaning or care products that contain abrasives, acids and/or chlorine. Such products would destroy the surfaces and could also damage the tech-nical components of the unit.
Maintenance of the unitThe components of the heating circuit and the heat source (valves, expansion vessels, circulation pumps, filters, dirt traps) should be checked and cleaned as necessary, however, at least annually, by qualified per-sonnel (heating or cooling system fitters).
It is best to sign a maintenance agreement with a heat-ing installation company. The company will arrange for the required maintenance at regular intervals.
MalfunctionsIn the event of a fault, you can read out the cause of the fault from the diagnostic program of the heating and heat pump regulator.
Operating manual of the heating and heat pump controller.
ATTENTION Only customer service personnel authorised
by the manufacturer may carry out service and repair work on the components of the unit.
Note that no malfunction is displayed if the safety tem-perature limiter on the electric heating element has tripped.
“Commissioning”, “Safety temperature limiter” section. Page 16
Scope of supply
1 Hydraulic module with integrated heating and heat pump controller
2 Safety assembly (in the case of the reversible variant these are the half-shells for insulation. The safety assembly itself is preassembled and installed.)
Example of layout of the accessory package:
1 Ball valve DN 32 (1x)2 Screws and anchors for
wall bracket (3x each)3 Ball valves DN 20 (2x)4 Heat transfer paste and clip for
fixing the return flow sensor5 Cable ties6 Strain relief screws (12x)7 Flat seals: 1" (2x), 1¼" (1x)not shown:Stickers for unit and cable labelling 2 jumpers for operation in the 230 V power supply system
1. Check the delivery for outwardly visible signs of damage.
7Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
2. Check the scope of supply for completeness. Any defects or incorrect deliveries must be report-
ed immediately.
NOTE Note the unit model.
“Technical Data / Scope of Supply” overview from Page 18 or rating plate on the unit.
Components of the unit2 versions of the hydraulic module are available:
HMD 2/(S)E
1 Heating circuit safety assembly (insulated)2 Control panel3 Switch cabinet4 Safety temperature limiter
with Reset button5 Flow inlet, heat pump 26 Flow inlet, heat pump 17 Flow outlet, heat pump 1 and 28 Instantaneous water heater 6 kW9 Energy efficient heating
circuit circulation pump
Reversible variant: HMD 2/R(S)E
1 Heating circuit safety assembly (insulated)2 Control panel3 Switch cabinet4 Safety temperature limiter
with Reset button5 Flow inlet, heat pump 26 Flow inlet, heat pump 17 Flow outlet, heat pump 1 and 28 Instantaneous flow heater 6 kW with
sensor tube for safety temperature limiter9 Energy efficient heating
circuit circulation pump
8 Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
InstallationThe following applies to all work to be done:
NOTE Always comply with the applicable local acci-
dent prevention regulations, statutory regula-tions, ordinances, guidelines and directives.
Installation location
ATTENTION Install the unit inside buildings only.
The installation room must be frost-free and dry. It must fulfil the relevant local regulations.
Dimensioned drawing (from Page 21) and in-stallation plan (from Page 24) for the respective model.
Transport to installation locationTo prevent damage during transport, always transport the unit to final installation location in its original pack-aging.
ATTENTION Never use components and hydraulic connec-
tions on the unit for transport purposes.
Installation1. 2 people are needed to lift the hydraulic module
out of the box.
2. Undo the quick-release screws in the top section of the hydraulic module and remove the top sec-tion from the front.
1 Quarter-turn screws
3. Remove the inner packaging material (transport safeguard).
4. Align the mounting rail in line with the drilling pat-tern at an appropriate height on the wall and mark the drillholes on the wall.
Note the drilling pattern (Page 23), safety and service spacings, see installation plan (from Page 24) for the respective model.
5. Use the plugs and screws supplied to secure the fixing rail onto the wall.
CAUTION Ensure the wall has the necessary load
bearing capacity. The anchors supplied are only suitable for use in
the following types of walls: ● Concrete ● Solid lightweight concrete blocks ● Cavity block made of lightweight concrete ● Cellular concrete ● Prestressed concrete - hollow ceiling/floor
slabs ● Natural stone with dense, close-grained micro-
structure ● Solid sand-lime bricks ● Perforated sand-lime bricks ● Solid bricks
9Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
● Vertically perforated (honeycomb) bricks ● Hollow floors/ceilings made of clay bricks, con-
crete or similar ● Solid gypsum boards ● Gypsum boards and gypsum fibre boards ● Particle boards
The board material must be dimensioned with suffi-cient thickness to ensure secure fixing.Appropriate fixing material must be provided on site for other types of wall constructions.
Mounting rail installed on the wall
ATTENTION Leaving a gap between the unit and the wall
helps back ventilation and may not be sealed or closed off.
Cable ducts must be laid at a distance of at least 2 cm from the hydraulic module.
CAUTION Hands and fingers could be crushed dur
ing the following tasks!6. 2 people are needed to hang the hydraulic mod-
ule in the mounting rail.
Unit lettering / labellingBefore making the hydraulic and electrical connection you must label the two heat pumps outdoors and their connection cables.
1. Remove all stickers for unit and cable labelling from the separate package included with the hy-draulic module.
2. Attach the larger sticker with number 1 in a clearly visible position on the outer façade of one of your heat pumps.
1
3. Attach the smaller stickers with number 1 to all connection cables of this heat pump 1 – at the ends which will later be connected to the hydraulic module. This way it is clear at the hydraulic mod-ule inside the building that these connection ca-bles lead to heat pump 1.
4. Attach the larger sticker with number 2 in a clear-ly visible position on the outer façade of your sec-ond heat pump.
2
5. Attach the smaller stickers with number 2 to all connection cables of this heat pump 2 – at the ends which will later be connected to the hydraulic module. This way it is clear at the hydraulic mod-ule inside the building that these connection ca-bles lead to heat pump 2.
10 Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
Installation / Hydraulic connection to heating circuitPressure loss calculation
NOTE There are two circulation pumps integrated in
the hydraulic module, which are appropriately dimensioned to ensure an adequately high vol-ume flow (flow rate) on the heat sink side. The free pressure available is limited, which makes planning in advance indispensable. For de-tails of how high the free pressures of the cir-culation pumps are at the corresponding heat pump volume flows, refer to the “free pressure” curves in the operating manual of the con-nected heat pumps.
Operating manuals of your heat pumps
A pressure loss calculation must be performed in ad-vance for the hydraulic connection of the hydraulic module, to dimension the components used (for ex-ample, the pipe diameter). This is the only way to de-termine the head of the still available free pressure, which is provided outside of the hydraulic module by the two integrated circulation pumps.
The free pressure available for the external piping of the heat sink side can be identified in the hydraulic module.
A calculation example of the hydraulic calculation / pressure loss calculation is given on Page 26 of this operating manual. On Page 27 there is a schematic, in which you can enter or calculate the data for your system.
The hydraulic components of a system must be cho-sen and dimensioned so that the sum of all pressure losses (heat pump, connection pipe, storage tank, changeover valves, heating circuit etc.) is less than the free pressure available in accordance with the operat-ing manual of the connected heat pumps.
As it is possible to operate two heat pumps with differ-ent heat outputs at the hydraulic module (for example, an LWD50A and an LWD70A) and therefore to operate them with different volume flows, this means that the two pipe runs of heat pump 1 and heat pump 2 can be loaded asymmetrically:
Depending on the connected heat pump types, the free pressure of pipe run 1, as a result of a higher pressure loss, can be lower than the free pressure of pipe run 2. In this case, for the further dimensioning it is important for the design to be based on the pipe run with the more unfavourable hydraulic conditions.
1. Calculate the hydraulics of your system in accord-ance with the schematic on Page 27 .
2. Flush the heating circuit thoroughly before con-necting the unit to the heating circuit.
NOTE Contamination and deposits in the heating cir-
cuit can cause malfunctions.
3. Install filling and draining devices, shut-off valves and non-return valves at the required locations in the heating circuit.
4. Check whether the units have already been la-belled. If not, label the units now.
Page 9, Unit lettering / labelling.
5. Make hydraulic connections to the hydraulic mod-ule according to the unit labelling. The connec-tions for the heating circuit are located on the un-derside of the hydraulic module.
NOTE The circulation pumps or rather the pipe runs
on or in the hydraulic module have already been labelled in the factory with number 1 for the connections of heat pump 1 and number 2 for the connections of heat pump 2.
ATTENTION When installing the connections, always se-
cure the connections on the unit against twist-ing, to prevent damage to the copper pipes in-side the unit.
11Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
1 Flow inlet, heat pump 12 Flow inlet, heat pump 23 Flow outlet, heat pump 1 and 2
“Hydraulic integration” documents.
Safety assemblyHMD 2/(S)EThe safety assembly for the heating circuit is in the ex-tra box. The connection for the safety assembly is lo-cated at the top of the hydraulic module.
1. Install the safety assembly at the connection pro-vided at the top of the hydraulic unit.
2. Lay the safety discharge of the safety valve via a funnel-shaped odour trap and into the drain ac-cording to the relevant standards and guidelines.
ATTENTION The safety discharge must be connected!
HMD 2/R(S)EThe safety assembly for the heating circuit is pre-in-stalled.
ATTENTION Perform leak test on the piping.
1. Take the insulation half-shells from the enclosed separate package and insulate the adapter from the hydraulic module to the safety assembly.
2. Lay the safety discharge of the safety valve via a funnel-shaped odour trap and into the drain ac-cording to the relevant standards and guidelines.
ATTENTION The safety discharge must be connected!
Expansion vessels
ATTENTION The expansion vessel for the heating circuit is
not included in the scope of supply! Always check whether the size of the expan-
sion vessel is large enough for the system. If necessary, an additional expansion vessel must be installed on site according to the rele-vant standards and guidelines.
NOTE The admission pressure of the expansion ves-
sel must be adjusted to the system (approx. 0.5 bar less than the system filling pressure) according to the calculation to the relevant standards (EN 12828).
12 Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
Electrical connectionsThe following applies to all work to be done:
DANGER Risk of fatal electric shock! All electrical connection work must be car
ried out by qualified electricians only. Before opening the unit, disconnect the
system from the power supply and prevent it from being switched back on!
WARNING Note and follow the relevant EN, VDE and/
or local safety regulations during installation and when carrying out electrical work.
Comply with technical connection requirements of the responsible power supply company (if required by the latter)!
WARNING Install electric connections only according
to the terminal diagram that applies to your model.
NOTE All live wires must be stripped before they are
installed in the cable duct of the switch cabi-nets!
ATTENTION The power supply for the heat pump and the
electric heating element must be equipped with an all-pole automatic circuit-breaker with at least 3 mm contact spacing to IEC 60947-2.
Note the level of the tripping current.
“Technical data / scope of supply” overview, “Elec-trics” section (from Page 18).
The electrical connection of the heat pumps outdoors is made only via the hydraulic module inside the build-ing.
“Schematic diagram of “Electrical connections”, Page 36
400 V / 230 V operationThe hydraulic module is compatible with heat pumps for the 3~400V power supply system (3~N/PE/400V/50Hz) and with heat pumps for the 1~230V power supply system (1~N/PE/230V/50Hz).
In the condition as-delivered from the factory the hy-draulic module is set up for operation with heat pumps for the 3~400V power supply system. You can see this condition as-delivered from the factory at the terminal block in the switch cabinet of the hydraulic module:
1L1
1L2
1L3
1N1
1N2
1N3
Condition as-delivered from the factory1 Jumper between 1N1 and 1N22 Jumper between 1N2 and 1N3
The following unit combinations are possible in condi-tion as-delivered from the factory (3~400V power sup-ply system):
Heat pump type Hydraulic moduleLWD 50A HMD 2/(S)ELWD 70A HMD 2/(S)ELWD 90A HMD 2/(S)ELWD 50A/RX HMD 2/R(S)ELWD 70A/RX HMD 2/R(S)E
Changeover 400 V connection to 230 VIf the hydraulic module is to be operated with heat pumps for the 1~230V power supply system, in addition to the jumpers in the condition as-delivered from the factory, you must set two additional jumpers between terminals 1L1 and 1L2 and between 1L2 and 1L3. The jumpers are enclosed in the separate package.
13Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
Electrical connection of the heat pumps to the hydraulic module
Example HMD 2/(S)E:
1 230 V inputs2 Terminal strip, external sensors3 LINBus cable connection
-X1 for heat pump 1 -X2 for heat pump 2
4 Terminal strip for control supply cables of the heat pumps
5 Terminal strip, power supply cables
● Heat pumps X8-1 for heat pump 1 X8-2 for heat pump 2
● Heating element6 Cable routing
1. Feed the connection cable through the ducts of the wall penetration from the outside into the in-side of the building. Use the lubricant.
807318
55
4080
9
D
E
11
D
O
EO
14
15
2x F 2x H
2x R
P
C
12
8b
90°
90°
90°
O
10O
3Ph/400V
a
b
16
13
2x U
17
i !i !
i
VV
ATTENTION When laying the cable, note that unshielded
power supply cables (power supply of outdoor units) and shielded cables (LINBus) must be laid separately from each other.
1L1
1L2
1L3
1N1
1N2
1N3
New jumpers to be set for operation in the 1~230V power supply system3 Jumper between 1L1 and 1L24 Jumper between 1L2 and 1L3
ATTENTION This termination is only allowed if the hydraulic
module is operated in the 1~230V power supply system and only with appropriate heat pumps designed for 1~230V power supply systems.
The following unit combinations are possible in the 1~230V power supply system:
Heat pump type Hydraulic moduleLWD 50A/SX HMD 2/(S)ELWD 70A/SX HMD 2/(S)ELWD 50A/RSX HMD 2/R(S)ELWD 70A/RSX HMD 2/R(S)E
ATTENTION Before each further action, check which heat
pump types are operated with the hydraulic mod-ule and if applicable set or remove jumpers.
Heat pumps for the 3~400V power supply sys-tem may not be operated in the 1~230V power supply system.
ATTENTION Heat pumps for the 1~230V power supply are
not available in all countries. Contact power company before the use of heat pumps for the 1~230V power supply.
14 Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
4. Connect LINBus cable of heat pump 1 to termi-nal strip -X1.
5. Connect LINBus cable of heat pump 2 to terminal strip -X2.
NOTE The Commissioning (startup) Wizard of the
heating and heat pump controller will give you instructions on addressing the heat pumps when you start up the system for the first time.
Then follow the instructions displayed in the screen of the heating and heat pump control-ler.
6. Connect the control supply cables of heat pump 1 and heat pump 2 to the terminal strip for control supply cables.
Heat pump-specific assignment (heat pump 1 / heat pump 2) is not necessary here; the two ca-bles can be connected to the relevant terminal strip in any order.
7. Use cable ties and heat transfer compound to fix the return sensor to the joint return (heat carrying pipe) of heat pumps 1 and 2.
Hydraulic integration documents
Unshielded power supply cables (power sup-ply of outdoor units) and shielded cables (LIN-Bus) must be laid with the following minimum distances between them:
without separator ≥ 50 mmseparator made of aluminium ≥ 20 mm
separator made of steel ≥ 2 mm
2. From the cable labelling, find out which cables come from heat pump 1 and which cables come from heat pump 2.
If the units and cables have not yet been labelled, label the units and cables now.
Page 9, Unit lettering / labelling.
3. Connect the supply cable of heat pump 1 to ter-minal strip 1 (X8-1) and the supply cable of heat pump 2 to terminal strip 2 (X8-2).
NOTE In the hydraulic module, the terminal strips
for these supply cables have already been la-belled in the factory with the number 1 for the supply cable of heat pump 1 and number 2 for the connections of heat pump 2.
1 2
1 Terminal strip X8-1 for heat pump 1 supply cable
2 Terminal strip X8-2 for heat pump 2 supply cable
15Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
8. Seal the cable penetrations for cables, which are routed from the heat pumps into the buildings, in the outdoor area.
NOTE The control panel of the heating and heat
pump controller can be connected to a com-puter or network, via the left-hand LAN socket on its underside, using a suitable network ca-ble, enabling the heating and heat pump con-troller to be controlled remotely from there.
If such a connection is required, install a shielded network cable (category 6, with RJ45 connector) during the electrical connection work and con-nect it parallel to the existing control cable of the heating and heat pump regulator.
The network cable can be added subsequently at any time.
Flushing, filling and bleeding the system
ATTENTION The system must be absolutely free from air
before commissioning. Contamination and deposits in the system can
cause malfunctions.
ATTENTION Do not exceed a pressure of 2.5 bar when
flushing the unit. The drain line of the heat-ing circuit safety valve must be closed before flushing and filling.
Example with storage tanks connected in series:
1. Connect the hose to the filling and draining tap and lay it to a drain.
2. Connect the filling and drain tap at the hydraulic module (heating water inlet from the heat pump).
3. Close the shut-off valves in the hydraulic mod-ule to the heat pump. Open shut-off valves to the heating circuit.
Example diagram: “Hot water circuit flushing and venting process”, Page 28
“Changeover valve” operating manual
4. Dismantle the motor of the 3-way valve for water heating (accessory). To do so, remove the U-bolt on the motor base and carefully pull off the motor from above..
5. Turn the stem through 180° and flush the hot wa-ter charging circuit for approx. 1 minute.
6. Turn the spindle 180° back to its starting position (rounded side of the stem points to B).
7. Flush the heating circuit! If necessary, the heating and hot water circuit can be flushed at the same time! To do so, turn stem through 30°.
Example diagram: “Heating circuit flushing and venting process”, Page 29
8. After completing the flushing and filling process, place the stem in the initial position and install the motor of the 3-way valve.
9. The unit vents automatically if the venters (black cap) of the safety assembly are open. If the heat-ing circuit is filled or emptied, the bleeding valve opens.
10. Open the shut-off valves in the hydraulic mod-ule to the heat pump. Close shut-off valves to the heating circuit. Close the shut-off valves on site to the heat pump:
Example diagram: “Flushing and venting process, heat pump 1”, Page 30
Example diagram: “Flushing and venting process, heat pump 2”, Page 31
11. Swap the hoses at the filling and draining taps and flush the condenser of the heat pump via the re-turn.
12. Also open the venting valve at the condenser of the heat pump. Vent the condenser and then close the venting valve again when fully vented.
Insulating the hydraulic connectionsYou must insulate the fixed piping of the heating cir-cuit, the connection pipes between the hydraulic mod-ule and the heat pump and the connections of the hot water tank.In (R) variant, vapour diffusion tight.
NOTE Insulate in accordance with applicable local
standards and guidelines/directives.
16 Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
Set the overflow valve REMARQUE
The activities in this section are only neces-sary for in-line tank integration.
Complete the worksteps quickly, otherwise the maximum return temperature can be exceeded and the heat pump switches to high-pressure fault.
Turn the adjusting knob at the overflow valve to the right to increase the temperature differ-ence (the temperature drop), turn it to the left to reduce it.
System is running in heating mode (ideally in cold condition).
1. In case of low heating curve: Set the system to “Forced heating”.
Operating manual of the heating and heat pump controller.
2. Shut off valves to the heating circuit.
3. Ensure that the total flow is routed via the over-flow valve.
4. Read out the flow and return temperature at the heating and heat pump controller.
Operating manual of the heating and heat pump controller.
5. Turn the adjusting knob (1) of the overflow valve (2) until the temperature drop between the flow and return temperature is set as follows:
External temperature Recommended settings-10 °C 4 K
0 °C 5 K10 °C 8 K20 °C 9 K30 °C 10 K
6. Open valves to heating circuit.
7. Reset the heating and heat pump controller.
Commissioning Follow the instructions in the section entitled
“Commissioning” in the operating manual for your heat pump.
Safety temperature limiterA safety temperature limiter is installed in the electric heating element. In the event of a malfunction in the heat pump or air in the system, check whether the re-set button of the safety temperature limiter has tripped. If this is the case, push in the button.
HMD 2/(S)E
1 Reset button of the safety temperature limiter at the electric heating element
17Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
Dismantling
DANGER Risk of fatal electric shock! All electrical work must be carried out by
qualified electricians only. Before opening the unit, disconnect the
system from the power supply and prevent it from being switched back on!
WARNING Only qualified heating or cooling system
technicians are allowed to remove the unit from the system.
ATTENTION Recycle or provide for proper disposal of unit
components in accordance with the applicable regulations, standards and directives.
Removing the buffer battery
ATTENTION Before scrapping the heating and heat pump
controller, remove the buffer battery on the control board. The battery can be pushed out using a screwdriver. Ensure environmentally compatible disposal of the battery and elec-tronic components.
HMD 2/R(S)E
1 Sensor tube on the electric heating element
2 Reset button of the safety temperature limiter
18 Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
Unit designationAccessories for LWD 50A - LWD 70A - LWD 90A - LWD 50A/SX - LWD 70A/SX • applicable ı — not applicable
Heat pump type LWD 50A/RX - LWD 70A/RX - LWD 50A/RSX - LWD 70A/RSX • applicable ı — not applicable
Functionally relevant • applicable ı — not applicable
Installation location Indoors ı Outdoors • applicable ı — not applicable
Maximum room temperature °C
Maximum relative humidity %
Conformity CE
Heating circuit Heating circuit efficiency pump integrated: • yes — no
Free pressure, heating circuit pump: ∆p **) ı ∆pmax ı Volume flow bar ı bar ı l/h
Volume flow: minimum flow rate ı maximum flow rate l/h
max. allowable operating pressure bar
Integrated expansion vessel ı Volume ı Initial pressure • yes — no ı l ı bar
Buffer tank integrated: • yes — no
Heat metering integrated: • yes — no
General unit data Total weight kg
Electric Voltage code ı all-pole fusing per heat pump LWD 50A*) … ı A
Voltage code ı all-pole fusing per heat pump LWD 70A*) … ı A
Voltage code ı all-pole fusing per heat pump LWD 90A*) … ı A
Voltage code ı all-pole fusing per heat pump LWD 50A/SX *) ***) … ı A
Voltage code ı all-pole fusing per heat pump LWD 70A/SX *) ***) … ı A
Voltage code ı circuit breaker control voltage *) … ı A
Voltage code ı fusing of electric heating element for 1~230V power supply system*) … ı A
Voltage code ı fusing of electric heating element for 3~230V power supply system*) … ı A
Voltage code ı fusing of electric heating element for 3~400V power supply system*) … ı A
Protection type IP
Output of electric heating element 3 ı 2 ı 1 phase kW ı kW ı kW
Circulating pump, heating circuit: maximum power consumption ı current consumption kW ı A
Safety equipment Safety assembly heating circuit ı Safety assembly heat source included in scope of supply: • yes — no
Heating and heat pump regulator included in scope of supply: • yes — no
Overflow valve integrated: • yes — no
*) comply with local regulations **) factory setting ***) Heat pump is not available in all countries
HMD2/(S)E • —•
• ı —3560• •
0,45 ı 0,45 ı 2 x 1600 2 x 900 ı 2 x 2000
3——•
393~/N/PE/400V/50Hz ı C163~/N/PE/400V/50Hz ı C163~/N/PE/400V/50Hz ı C16
1~/N/PE/230V/50Hz ı 2 x C161~/N/PE/230V/50Hz ı 2 x C20
1~/N/PE/230V/50Hz ı B16
1~/N/PE/230V/50Hz ı B403~/PE/230V/50Hz ı B25A
3~/N/PE/400V/50Hz ı B16A
209 ı 6 ı 3
2 x 0,06 ı 2 x 0,26• ı —
•—
813315
Technical data/Scope of supply
19Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
Unit designationAccessories for LWD 50A - LWD 70A - LWD 90A - LWD 50A/SX - LWD 70A/SX • applicable ı — not applicable
Heat pump type LWD 50A/RX - LWD 70A/RX - LWD 50A/RSX - LWD 70A/RSX • applicable ı — not applicable
Functionally relevant • applicable ı — not applicable
Installation location Indoors ı Outdoors • applicable ı — not applicable
Maximum room temperature °C
Maximum relative humidity %
Conformity CE
Heating circuit Heating circuit efficiency pump integrated: • yes — no
Free pressure, heating circuit pump: ∆p **) ı ∆pmax ı Volume flow bar ı bar ı l/h
Volume flow: minimum flow rate ı maximum flow rate l/h
max. allowable operating pressure bar
Integrated expansion vessel ı Volume ı Initial pressure • yes — no ı l ı bar
Buffer tank integrated: • yes — no
Heat metering integrated: • yes — no
General unit data Total weight kg
Electric Voltage code ı all-pole fusing per heat pump LWD 50A*) … ı A
Voltage code ı all-pole fusing per heat pump LWD 70A*) … ı A
Voltage code ı all-pole fusing per heat pump LWD 90A*) … ı A
Voltage code ı all-pole fusing per heat pump LWD 50A/SX *) ***) … ı A
Voltage code ı all-pole fusing per heat pump LWD 70A/SX *) ***) … ı A
Voltage code ı circuit breaker control voltage *) … ı A
Voltage code ı fusing of electric heating element for 1~230V power supply system*) … ı A
Voltage code ı fusing of electric heating element for 3~230V power supply system*) … ı A
Voltage code ı fusing of electric heating element for 3~400V power supply system*) … ı A
Protection type IP
Output of electric heating element 3 ı 2 ı 1 phase kW ı kW ı kW
Circulating pump, heating circuit: maximum power consumption ı current consumption kW ı A
Safety equipment Safety assembly heating circuit ı Safety assembly heat source included in scope of supply: • yes — no
Heating and heat pump regulator included in scope of supply: • yes — no
Overflow valve integrated: • yes — no
*) comply with local regulations **) factory setting ***) Heat pump is not available in all countries
HMD2/R(S)E—••
• ı —3560• •
0,45 ı 0,45 ı 2 x 1600 2 x 900 ı 2 x 2000
3——•
403~/N/PE/400V/50Hz ı C163~/N/PE/400V/50Hz ı C163~/N/PE/400V/50Hz ı C16
1~/N/PE/230V/50Hz ı 2 x C161~/N/PE/230V/50Hz ı 2 x C20
1~/N/PE/230V/50Hz ı B16
1~/N/PE/230V/50Hz ı B403~/PE/230V/50Hz ı B25A
3~/N/PE/400V/50Hz ı B16A
209 ı 6 ı 3
2 x 0,06 ı 2 x 0,26• ı —
•—
813316
20 Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
Bezeichnung:
Datei: 812036 Freie Pressung HMD 2
Seite: 1/1
Zeichnungsnummer:
Legende:“v” Volumenstrom Heizwasser in m3/h je Pumpenzweig, zwei Zweige verfügbar∆pmax maximale freie Pressung
Freie Pressung HMD 2
812036
Änd./ÄM/Ersteller/Datum
- /PEP 005-2014 / Mödder / 21.02.2014
812036
0,0
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,0 0,5 1,0 1,5 2,0 2,5 3,0
Δpm
ax [b
ar]
Δpmax
Δp
“” [m3/h]
Keys: UK812036
“” Heating water volume flow in m³/h per pump branch, two branches available∆pmax maximum free pressure
HMD 2/… Free pressure
21Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
951
695
650
134
590
109 109 108
125
1
46 5 3 2 93
108
280
79
11
Legende: D819439 Alle Maße in mm.
A Vorderansicht D Seitenansicht von rechts
Das Hydraulikmodul wird im Heizungsvorlauf installiert!
D A
87654321
www.ait-deutschland.euD - 95359 Kasendorf
Industriestraße 3ait-deutschland GmbH
1
1
Ers. d. Ers. f.
A
B
C
D
E
F F
E
D
C
B
A
4321
Benennung
Zust. Änderungstext
Datum
Von
Blatt
von
Werkstoff Gewicht
Maßstab 1:10 Det. Maßstab
Datum NameErstelltGepr.Norm.
24.4.2014 Aepfelbach
toleranzAllgemein- Oberflächen
ArtikelNr.
Schu
tzver
merk
ISO
1601
6 bea
chten
DIN ISO 2768 -c
Aepfelbach24.4.2014koex110.4.2014
RA
23.4.2014
PEP 005/2014-
819439
Hydraulikmodul HMD2 150858Maßbild
Keys: UK819439All dimensions in mm.
A Front viewD Side view from right
The hydraulic module is installed in the heating flow!
Pos. Designation Dim.1 Control element2 Penetrations for electric/sensor cables3 Return flow sensor approx. 5.5 m from unit4 Heating water inlet (from heat pump 2) Rp 1" IG5 Heating water outlet (flow) Rp 1¼" IG6 Heizwasser Eintritt (von Wärmepumpe 1) Rp 1" IG
Dimensioned drawings HMD 2/(S)E
22 Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
103
7
125
695
650
590
109 109 108
134
1
6 5 4 3 2
270
79
108
93
11
Legende: D819440 Alle Maße in mm.
A Vorderansicht D Seitenansicht von rechts
Das Hydraulikmodul wird im Heizungsvorlauf installiert!
D A
87654321
www.ait-deutschland.euD - 95359 Kasendorf
Industriestraße 3ait-deutschland GmbH
1
1
Ers. d. Ers. f.
A
B
C
D
E
F F
E
D
C
B
A
4321
Benennung
Zust. Änderungstext
Datum
Von
Blatt
von
Werkstoff Gewicht
Maßstab 1:10 Det. Maßstab
Datum NameErstelltGepr.Norm.
24.4.2014 Aepfelbach
toleranzAllgemein- Oberflächen
ArtikelNr.
Schu
tzverm
erk IS
O 16
016 b
each
ten
DIN ISO 2768 -c
Aepfelbach24.4.2014koex110.4.2014
RA
24.4.2014
PEP 005/2014-
819440
Hydraulikmodul HMD2 rev 150859Maßbild
Keys: UK819440All dimensions in mm.
A Front viewD Side view from right
The hydraulic module is installed in the heating flow!
Pos. Designation Dim.1 Control element2 Penetrations for electric/sensor cables3 Return flow sensor approx. 5.5 m from unit4 Heating water inlet (from heat pump 2) Rp 1" IG5 Heating water outlet (flow) Rp 1¼" IG6 Heizwasser Eintritt (von Wärmepumpe 1) Rp 1" IG
HMD 2/R(S)E Dimensioned drawings
23Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
250 250 69
470
2
15
12
1
2
Legende: D819443 Alle Maße in mm. Bohrung 12 für Dübel (im Beipack)
87654321
www.ait-deutschland.euD - 95359 Kasendorf
Industriestraße 3ait-deutschland GmbH
1
1
Ers. d. Ers. f.
A
B
C
D
E
F F
E
D
C
B
A
4321
Benennung
Zust. Änderungstext
Datum
Von
Blatt
von
Werkstoff Gewicht
Maßstab 1:10 1:5Det. Maßstab
Datum NameErstelltGepr.Norm.
24.4.2014 Aepfelbach
toleranzAllgemein- Oberflächen
ArtikelNr.
Schu
tzverm
erk IS
O 16
016 b
each
ten
DIN ISO 2768 -c
Aepfelbach24.4.2014Aepfelbach11.4.2014
RA
24.4.2014
PEP 005/2014-
819443
Bohrbild für Wandaufhängung HMD2Maßbild
Keys: UK819443All dimensions in mm.Hole Ø 12 for anchor (enclosed in separate package)
Pos. Designation1 Wall mounting rail (in separate package)2 Sheet metal housing
HMD 2/…Drilling pattern
24 Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
>1350
>200 >600
>17
0
FS
OKF
>50
0 >80
0
FS
Legende: 819441Alle Maße in mm.
OKF Oberkante FertigfussbodenFS Freiraum für Servicezwecke
87654321
www.ait-deutschland.euD - 95359 Kasendorf
Industriestraße 3ait-deutschland GmbH
1
1
Ers. d. Ers. f.
A
B
C
D
E
F F
E
D
C
B
A
4321
Benennung
Zust. Änderungstext
Datum
Von
Blatt
von
Werkstoff Gewicht
Maßstab 1:50 1:20Det. Maßstab
Datum NameErstelltGepr.Norm.
24.4.2014 Aepfelbach
toleranzAllgemein- Oberflächen
ArtikelNr.
Schu
tzverm
erk IS
O 16
016 b
each
ten
DIN ISO 2768 -c
Aepfelbach24.4.2014koex110.4.2014
RA
23.4.2014
-
819441
Hydraulikmodul HMD 2, nur heizenAufstellungsplan, Mindestabstände
Keys: UK819441All dimensions in mm.
Pos. DesignationOKF Top edge of finished floorFS Free space for service purposes
Installation planHMD 2/(S)E
25Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
>200
>1350
>600 >
255
FS
OKF >
500 >
800
FS
Legende: 819442Alle Maße in mm.
OKF Oberkante FertigfussbodenFS Freiraum für Servicezwecke
87654321
www.ait-deutschland.euD - 95359 Kasendorf
Industriestraße 3ait-deutschland GmbH
1
1
Ers. d. Ers. f.
A
B
C
D
E
F F
E
D
C
B
A
4321
Benennung
Zust. Änderungstext
Datum
Von
Blatt
von
Werkstoff Gewicht
Maßstab 1:50 1:20Det. Maßstab
Datum NameErstelltGepr.Norm.
24.4.2014 Aepfelbach
toleranzAllgemein- Oberflächen
ArtikelNr.
Schu
tzverm
erk IS
O 16
016 b
each
ten
DIN ISO 2768 -c
Aepfelbach24.4.2014koex110.4.2014
RA
23.4.2014
-
819442
Hydraulikmodul rev 150711/12Aufstellungsplan, Mindestabstände
Keys: UK819442All dimensions in mm.
Pos. DesignationOKF Top edge of finished floorFS Free space for service purposes
Installation plan HMD 2/R(S)E
26 Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
0 Pa
RP
V1T1 LWD 50A
Vnom
V2T2 LWD 70A
Vnom
A1 HVLD 3m
A2 HVLD 3m
AV1 1.200 l/h
AV2 1.600 l/h
D1 3.000 Pa
D2 5.000 Pa
AV 2.800 l/h
21.820 Pa
WP1
WP2
21.820 Pa0,22 bar
RP
Calculation example
WP1 Heat pump 1T1 Type heat pump 1V1 Volume flow heat pump 1
(Vmin, Vnom or Vmax of heat pump 1)A1 Type of connection pipe heat pump 1AV1 Design volume flow heat pump 1D1 Pressure loss of the external
components used WP2 Heat pump 2T2 Type heat pump 2V2 Volume flow heat pump 2
(Vmin, Vnom or Vmax of heat pump 2)A2 Type of connection pipe heat pump 2AV2 Design volume flow heat pump 2D2 Pressure loss of the external
components usedAV Volume flow in joint flowRP Maximum free pressure, which is available
for the pressure loss of the heat sinkCalculation of pressure loss, heat pump 1 (here: LWD 50A)at AV1 of 1,200 l/h
Inherent pressure loss of heat pump 6,000 Pa
+ Inherent pressure loss of connection kit 5,000 Pa
+ Inherent pressure loss of connection pipe HVLD / WDF
1,080 Pa
= Pressure loss, heat pump 1 (at entry into building)
12,080 Pa
Calculation of pressure loss, heat pump 2 (here: LWD 70A)at AV1 of 1,600 l/h
Inherent pressure loss of heat pump 6,000 Pa
+ Inherent pressure loss of connection kit 8,500 Pa
+ Inherent pressure loss of connection pipe HVLD / WDF
1,680 Pa
= Pressure loss, heat pump 2 (at entry into building)
16,180 Pa
Calculation of RP with LWD 50A + LWD 70APressure loss, heat pump 1 12,080 Pa
+ Pressure loss, external components (D1) 3,000 Pa= Interim result 1 15,080 Pa
Pressure loss, heat pump 2 16,180 Pa+ Pressure loss, external components (D2) 5,000 Pa= Interim result 2 21,180 Pa
Total free pressure, hydraulic module, for heat pump of the more unfavourable interim result
43,000 Pa
– more unfavourable interim result 21,180 Pa= RP 21,820 Pa
Volume flows (V1 / V2) heat pump
T1 / T2V in m³/h
Vmin Vnom VmaxLWD 50A/… 900 1200 1500LWD 70A/… 1200 1600 2000LWD 90A/… 1600 2000 2500
Inherent pressure losses of heat pump
T1 / T2Δp in Pa
Vmin Vnom VmaxLWD 50A/… 4000 6000 10000LWD 70A/… 3000 6000 8000LWD 90A/… 5000 7000 12000
Inherent pressure losses of connection kit
T1 / T2Δp in Pa
Vmin Vnom VmaxLWD 50A/… 3000 5000 8000LWD 70A/… 5000 8500 14000LWD 90A/… 8500 14000 25000
Inherent pressure losses of connection pipe
T1 / T2Δp in Pa (HVLD/WDF per m)
Vmin Vnom VmaxLWD 50A/… 100 180 260LWD 70A/… 180 280 400LWD 90A/… 280 400 600
Total free pressure of hydraulic module
T1 / T2Δp in Pa
Vmin Vnom VmaxLWD 50A/… 68000 60000 47000LWD 70A/… 60000 43000 26000LWD 90A/… 43000 26000 8000
Type of connection pipe (A1 / A2)WDF 1m 1HVLD 3m 3HVLD 8m 8HVLD 14m 14HVLD 20m 20
27Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
0 Pa
RP
V1T1
V2T2
A1
A2
AV1
AV2
D1
D2
AV
WP1
WP2
RP
*)*)
*)*)
*)
*)
*)
*)
*)
*)
*)
*)
*)
Calculation of your system
Complete all fields and table rows marked with an asterisk *).
1. In the grey field T1, enter the type of your heat pump 1, enter the type of your heat pump 2 in the field T2.
2. When entering the value for V1 and V2, decide whether the dimensioning is to be carried out on the basis of Vmin (approx. 8 K difference), Vnom (5 K difference) or Vmax (approx. 3 K difference). Enter the value for the chosen dimensioning in the field V1 or V2.
3. Enter the design volume flow of heat pump 1 in the field AV 1, the design volume flow of heat pump 2 in the field AV2 and in the respective cal-culation tables.
4. Enter the design volume flow of the external com-ponents in the field AV.
5. Determine the pressure loss of the external com-ponents for heat pump 1 pipe run and enter in field D1.
6. Determine the pressure loss of the external com-ponents for heat pump 2 pipe run and enter in field D2.
7. Enter the inherent pressure loss of heat pump 1 (depending on Vmin, Vnom or Vmax) in calcula-tion table 1 and the inherent pressure loss of heat pump 2 (depending on Vmin, Vnom or Vmax) in cal-culation table 2.
8. Enter the inherent pressure loss of the connection kit of heat pump 1 in calculation table 1 and the in-herent pressure loss of the connection kit of heat pump 2 in calculation table 2 .
9. Enter the type of connection pipe for heat pump 1 in the grey field A1 and the type of connection pipe for heat pump 2 in the grey field A2.
10. Add the inherent pressure losses in the calcula-tion tables to the pressure loss of heat pump 1 and to the pressure loss of heat pump 2.
Calculation table for heat pump 1 pressure loss 1at AV1 of *) l/h
Inherent pressure loss of heat pump *) Pa
+ Inherent pressure loss of connec-tion kit *) Pa
+ Inherent pressure loss of connec-tion pipe HVLD / WDF *) Pa
= Pressure loss, heat pump 1 (at entry into building)
*) Pa
Calculation table for heat pump 2 pressure loss 1at AV2 of *) l/h
Inherent pressure loss of heat pump *) Pa+ Inherent pressure loss of connec-
tion kit *) Pa
+ Inherent pressure loss of connec-tion pipe HVLD / WDF *) Pa
= Pressure loss, heat pump 2 (at entry into building)
*) Pa
11. Calculate value RP and enter in the RP fields shown in the above figure.
RP calculationPressure loss, heat pump 1 *) Pa
+ Pressure loss of ext. components (D1) *) Pa= Interim result 1 *) Pa
Pressure loss, heat pump 2 *) Pa+ Pressure loss of ext. Components (D2) *) Pa= Interim result 2 *) PaTotal free pressure, hydraulic module, for heat pump of the more unfavour-able interim result
*) Pa
– more unfavourable interim result *) Pa= RP *) Pa
28 Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
26 BUP
A
BAB
TAA
1
37
72
7 24
31
1
37
31
O
Z
VL HW
RL HW
RL WW
ZOZ
Keys:VL HW Heating water flow 1 Heat pumpRL WW Hot water return 7 Safety valveZ Shut-off valve closed 24 Pressure gaugeO Shut-off valve open 26 Hot water changeover valve (BUP)
31 Wall penetration37 Wall bracket
TA A Outdoor sensor 72 Wall-mounted buffer tank
Flushing and venting process, hot water circuit
ATTENTION Changeover valve (BUP)
must be open in the direc-tion of the hot water circuit.
29Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
26 BUP
A
BAB
TAA
1
37
72
7 24
31
1
37
31
O
Z
VL HW
RL HW
RL WW
ZOZ
Keys:VL HW Heating water flow 1 Heat pumpRL WW Hot water return 7 Safety valveZ Shut-off valve closed 24 Pressure gaugeO Shut-off valve open 26 Hot water changeover valve (BUP)
31 Wall penetration37 Wall bracket
TA A Outdoor sensor 72 Wall-mounted buffer tank
Flushing and venting process, heating circuit
ATTENTION Changeover valve (BUP)
must be open in the direc-tion of the heating circuit.
30 Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
TAA
1
37
72
7 24
31
1
37
31
Z
Z Z
VL HW
RL HW
RL WW
O
Keys:VL HW Heating water flow 1 Heat pumpRL WW Hot water return 7 Safety valveZ Shut-off valve closed 24 Pressure gaugeO Shut-off valve open 26 Hot water changeover valve (BUP)
31 Wall penetration37 Wall bracket
TA A Outdoor sensor 72 Wall-mounted buffer tank
Flushing and venting process, heat pump 1
31Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
TAA
1
37
72
7 24
31
1
37
31
Z
VL HW
RL HW
RL WW
Z
O Z
Keys:VL HW Heating water flow 1 Heat pumpRL WW Hot water return 7 Safety valveZ Shut-off valve closed 24 Pressure gaugeO Shut-off valve open 26 Hot water changeover valve (BUP)
31 Wall penetration37 Wall bracket
TA A Outdoor sensor 72 Wall-mounted buffer tank
Flushing and venting process, heat pump 2
32 Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
Row tankHMD 2/…
33Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
Separate buffer tank and unit variant R (cooling)
HMD 2/…
34 Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
Lege
nd h
ydra
ulic
dia
gram
m14
0304
1H
eat p
ump
51Se
pera
tion
tank
TA/A
Exte
rnal
sen
sor
2U
nder
floor
hea
ting
/ rad
iato
rs52
Gas
- or o
il-bo
iler
TBW
/BD
omes
tic h
ot w
ater
sen
sor
3Vi
brat
ion
isol
atio
n53
Woo
d bo
iler
TB1/
CFe
edw
ater
sen
sor m
ixer
circ
uits
14
Sylo
mer
stri
p m
achi
ne u
nder
lay
54H
ot w
ater
cyl
inde
rD
Floo
r tm
pera
ture
lim
iter
5C
losu
re a
nd d
rain
age
55Br
ine
pres
sure
sw
itch
TRL/
GSe
nsor
ext
erna
l ret
urn
6Ex
pans
ion
vess
el p
acki
ng li
st56
Swim
min
g po
ol h
eat e
xcha
nger
STA
Line
pre
ssur
e re
gula
tor v
alve
7Sa
fety
val
ve57
Geo
ther
mal
hea
t exc
hang
erTR
L/H
Sens
or re
turn
(hyd
raul
ic m
odul
e, d
ual)
8C
losu
re
58Ve
ntila
tion
syst
em9
Hea
ting
circ
ulat
ion
pum
p59
Plat
e he
at e
xcha
nger
79M
otor
val
ve10
Non
retu
rn v
alve
/ one
way
val
ve61
Coo
ling
cylin
der
80M
ixin
g va
lve
11In
divi
dual
room
regu
latio
n65
Com
pact
dis
tribu
tor
81Sp
lit h
eat p
ump
outd
oor u
nit
12O
verfl
ow v
alve
66Fa
ncoi
ls82
Split
hea
t pum
p in
door
uni
t 13
Stea
mtig
ht in
sula
tion
67So
lar/
serv
ice
wat
er c
ylin
der
83C
ircul
atio
npu
mp
14Se
rvic
e w
ater
circ
ulat
ion
pum
p68
Sola
r/ se
rvic
e w
ater
cyl
inde
r84
Switc
hing
val
ve15
Mix
er c
ircui
t thr
ee-w
ay m
ixer
(MK1
dis
char
ge)
69M
ultif
unct
ion
tank
113
Con
nect
ion
2nd
heat
gen
erat
or
16
Expa
nsio
n ve
ssel
sup
plie
d by
cus
tom
er71
Dua
l hyd
raul
ic m
odul
eBT
1O
utdo
or te
mpe
ratu
re s
enso
r18
Hea
ting
rod
(hea
ting)
72Bu
ffer t
ank
wal
l mou
nted
BT2
Flow
tem
pera
ture
sen
sor
19M
ixer
circ
uit f
our-w
ay m
ixer
(MK1
cha
rge)
73Pi
pe le
ad-in
BT3
Ret
urn
tem
pera
ture
sen
sor
20H
eatin
g ro
d (S
W)
74Ve
ntow
erBT
6D
omes
tic h
ot w
ater
tem
pera
ture
sen
sor
21M
ixer
circ
uit c
ircul
atio
n pu
mp
(FP1
)75
Scop
e of
del
iver
y, h
ydra
ulic
tow
er, d
ual
BT12
Flow
tem
pera
ture
liqu
efie
r23
Feed
circ
ulat
ing
pum
p (re
conn
ect t
he in
tegr
ated
circ
ulat
ing
pum
p in
the
heat
pum
p)76
Fres
h w
ater
sta
tion
BT19
Tem
pera
ture
sen
sor i
mm
ersi
on h
eate
r
24M
anifu
ld77
Scop
e of
sup
ply
wat
er/w
ater
boo
ster
BT24
Tem
pera
ture
sen
sor 2
nd h
eat g
ener
ator
25H
eatin
g ci
rcul
atio
n pu
mp
78Ac
cess
orie
s w
ater
/wat
er b
oost
er o
ptio
nal
26
Switc
hing
val
ve (h
eatin
g/se
rvic
e w
ater
)(B =
nor
mal
ly o
pen)
27H
eatin
g el
emen
t28
Brin
e ci
rcul
atio
n pu
mp
Com
fort
boar
d:29
Dirt
-trap
0.6
mm
mes
h15
Mix
er c
ircui
t thr
ee-w
ay m
ixer
(MK2
-3 d
isch
arge
)30
Spill-
tray
für b
rine
mix
100
Roo
m th
erm
osta
t for
coo
ling
(opt
iona
l)17
Tem
pera
ture
diff
eren
ce re
gula
tor
31W
all b
reak
thro
ugh
101
Con
trols
sup
plie
d by
cus
tom
er19
Mix
er c
ircui
t fou
r-way
mix
er (M
K2 c
harg
e)32
Inle
t pip
e10
2D
ew-p
oint
mon
itor (
optio
nal)
21M
ixer
circ
uit c
ircul
atio
n pu
mp
(FP2
-3)
33Br
ine
man
ifuld
103
Roo
m th
erm
osta
t for
refe
renc
e sp
ace
in p
acki
ng li
st22
Swim
min
g po
ol c
ircul
atin
g pu
mp
34G
roun
d co
llect
or10
4Su
pply
hea
t pum
p44
Thre
e-w
ay m
ixer
val
ve (c
oolin
g fu
nctio
n M
K2)
35G
roun
d sl
inki
es10
5C
oolin
g ci
rcui
t mod
ule
box
rem
ovea
ble
for i
nsta
llatio
n47
C
hang
eove
r val
ve s
wim
min
g ba
th p
repa
ratio
n(B
= no
rmal
ly o
pen)
36G
roun
dwat
er s
prin
g pu
mp
106
Spec
ific
glyc
ole
mix
ture
60C
hang
eove
r val
ve c
oolin
g op
erat
ion(
B =
norm
ally
ope
n)37
Wal
l bra
cket
107
Scal
d pr
otec
tion
/ the
rmos
tatic
mix
er v
alve
62H
eat m
eter
(opt
iona
l)38
Flow
sw
itch
108
Sola
r pum
p as
sem
bly
63C
hang
eove
r val
ve s
olar
circ
uit(B
= n
orm
ally
ope
n)39
Suct
ion
wel
l10
9O
verfl
ow v
alve
mus
t be
clos
ed64
Coo
ling
circ
ulat
ion
pum
p40
Inve
rted
wel
l11
0Pa
ckin
g lis
t hyd
raul
ic to
wer
70So
lar s
eper
atio
n m
odul
e41
Rin
se fi
tting
hea
ting
circ
uit
111
Mou
ntin
g fo
r add
ition
al h
eatin
g el
emen
tTB
2-3/
CFe
edw
ater
sen
sor m
ixer
circ
uits
2-3
42C
ircul
atio
n pu
mp
112
Min
imum
dis
tanc
e to
ther
mal
dec
oupl
ing
of th
e m
ixin
g va
lve
TSS/
ESe
nsor
, tem
pera
ture
diff
eren
ce c
ontro
l (lo
w te
mpe
ratu
re)
43Br
ine
/ Wat
er h
eat e
xcha
nger
(coo
ling
func
tion)
TSK/
ESe
nsor
, tem
pera
ture
diff
eren
ce c
ontro
l (hi
gh te
mpe
ratu
re)
44Th
ree-
way
mix
er v
alve
(coo
ling
func
tion
MK1
)TE
E/F
Sens
or e
xter
nal e
nerg
y so
urce
45C
ap v
alve
46Fi
ller a
nd d
rain
age
valv
e48
Dom
estic
hot
wat
er c
harg
ing
pum
p49
Dire
ctio
n of
gro
undw
ater
flow
50Bu
ffer s
tora
ge
Impo
rtant
not
ice
!
Thes
e hy
drau
lic d
iagr
ams
are
sche
mat
ic re
pres
enta
tions
and
are
for a
ssis
tanc
e on
ly. T
hey
do n
ot re
lieve
of t
he o
blig
atio
n to
car
ry o
ut a
ppro
pria
te p
lann
ing!
The
y do
not
incl
ude
all n
eces
sary
shu
t-off
valv
es, v
entil
ator
fit
tings
or s
afet
y de
vice
s. T
hese
mus
t be
inco
rpor
ated
in a
ccor
danc
e w
ith th
e st
anda
rds
and
regu
latio
ns a
pplic
able
to th
e re
spec
tive
inst
alla
tion.
All
coun
try-s
peci
fic s
tand
ards
, law
s an
d re
gula
tions
mus
t be
obse
rved
! The
tu
bes
have
to b
e di
men
sion
ed a
ccor
ding
to th
e no
min
al v
olum
e flo
w o
f the
hea
t pum
p re
sp. t
he fr
ee p
ress
ing
of th
e in
tegr
ated
circ
ulat
ing
pum
p. F
or d
etai
led
info
rmat
ion
and
advi
ce p
leas
e co
ntac
t our
loca
l sal
es p
artn
er!
35Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
36 Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
UV
Z-VD 1
Z-VD 2
Z-HS
Z-ST
WS
1 2
3
HWE-1 HWE-2
HWA(VL)
Z-1 Z-2
ATTENTION When laying the cable, note that unshielded power supply cables (power supply of outdoor
units) and shielded cables (LINBus) must be laid separately from each other. Minimum spacings for cable laying, Page 13
Keys:UV Electricity subdistribution
Z-VD 1 Supply cable for compressor of heat pump 1
Z-VD 1 Supply cable for compressor of heat pump 2
Z-HS Supply cable for heating element
Z-ST Supply cable for controls
HWE-1 Heating water inlet from heat pump 1
HWE-2 Heating water inlet from heat pump 2
HWA (VL) Heating water outlet (flow)
WS Heat sink
1 Heat pump 1Z-1 Supply cables for heat pump 1
(label each with sticker 1!)1 x Supply cable for compressor1 x Supply cable for controls1 x LINBus connection (Note minimum
distance from compressor and controls supply cable!)
2 Heat pump 2Z-1 Supply cables for heat pump 2
(label each with sticker 2!)1 x Supply cable for compressor1 x Supply cable for controls1 x LINBus connection (Note minimum
distance from compressor and controls supply cable!)
3 Hydraulic module HMD 2/(S)E or HMD 2/R(S)E
Schematic diagram of the electrical connections
37Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
-F11
-F12
-F9
-F10
A1
A2
3
-X2
3
-X1
22
11
1P
E
X10
3~N/PE/400V/50Hz
Lin-Bus distrib
utor circuit board
PE
3
X10-2
L3
X8
N
X20
L3
A4
N
IN2
NTC7
LIN-1
PE
13
-X5
-2
A1
1
L2
L1
/ A
PE
A2
OUT5
3-pole miniature circuit-breaker of com
pressor; Attention: C
lockwise
rotary field is absolutely necessary! WP
2
-X5
-1
L1
GND1
OUT7
NTC6
Sub-distribution unit intern
al installation
3~N/PE/400V/50Hz
UK
83
1187
am
ps
ZIP
GND5
M
1~N/PE/230V/50Hz
Pum
p for mixing circuit 1
GND4
FP
1
IN5
L2
/ B
5
N
EV
U
-X1
0
Sensor m
ixing circuit 1
NTC9
IN1
L1
NTC5
NTC1
GND2
PE
OUT2
GND3
GND6
NTC8
OUT1
B
GN
D
L1
L
-X3
-2
HU
P
-X4
BWT
TB1
GND8
N
3
OUT4
GND7
TRL
M
IN5
L1
OUT6
OUT3
FP
1
Cut out a
uxiliary heating
A3
OUT8
IN4
5
NTC2
N
12V
ZU
P
-X3
-1
Auxiliary circulation pum
p
1L2
F12
BU
P
OU
T4
Heat pu
mp 1
HU
P
1L3
NT
C2
OU
T6
MA
1/MIS
IN3
TRL ext.
IN1
OU
T8
NTC4
1N3
Heat pu
mp 2
NTC3
Controller board; A
ttention: I-max =
6A
/230VA
C
OU
T2
IN4
TA
ZW
1
3-pole miniature circuit-breaker of com
pressor; Attention: C
lockwise
rotary field is absolutely necessary! WP
1F
9
2
Lin-2
F10
NT
C8
24
40
0V
po
we
r su
pp
ly
1N2
MZ
1/MIS
4
IN2
X8-2
X10-1
circulation pump
X8-1
OU
T3
A1
NT
C4
X8
NT
C5
5
X20
NT
C3
-X6
A3
TA
1L1
2
1N1
L
Term
inal strip in sw
itch box wall regu
lator; N/P
E distribution for external 2
30V devices
Return sensor
I nfo
rmatio
n o
n fu
se
s c
an
be fo
un
d in
the te
ch
nic
al d
ata
ZU
P
TR
L ext.
OU
T5
A4
Nam
e
Heating circuit circulating pum
p
External return sensor
Safety tem
perature limiter for underfloor heating
, bridge if not available
TB
1
External sensor
F11
ST
B F
BH
Charge/discharge/m
ixer 1 open
IN3
Hot w
ater gauge/therm
ostat
X10
ZIP
PE
BU
P
TR
L
OU
T7
Cut out controller unit
GND9
BW
T
3~N/PE/400V/50Hz
Function
Charge/discharge/m
ixer 1 closed
OU
T1
Leg
en
d:
EV
U1
Diverting valve for dom
estic hot water
Term
inals
Energy supplier contact; close
d on release; bridge if no blocking inte
rval
A2
Control signal of add
itional heat generator
Abbreviation
MIS
EV
U2
27.0
5.2
014
1
A. P
fleger
1/2
Achim
Pfleg
er0
1.04.2
014
Hydraulic m
odule 2831187
12
34
56
78
12
34
56
78
-P
EP
005-2014
Bl vo
n An
z
Nam
e
Datu
m
Zusta
nd
Blatt-N
r.
Bea
rb.
Datu
mÄ
nde
rung
Terminal diagram 400V: LWD … / HMD 2/…
38 Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
-.F11
-.F12
-.F9
-.F1
0
A1
A2
3
-X2
3
-X1
22
11
Function
23
0V
po
we
r su
pp
ly
OU
T7
OU
T8
1~N/PE/230V/50Hz
BW
T
IN3
BU
P
X10
PE
ZIP
NTC4
Cut out controller unit
1N3
GND9
IN2
IN1
TRL ext.
L
NT
C3
Term
inal strip in sw
itch box wall regu
lator; N/P
E distribution for external 2
30V devices
OU
T2
Control signal of add
itional heat generator
TR
LR
eturn sensor
EV
U1
Info
rmatio
n o
n fu
se
s c
an
be fo
un
d in
the te
ch
nic
al d
ata
TA
A3
Hot w
ater gauge/therm
ostat
TR
L ext.
ZU
P
A2
Abbreviation
EV
U2
NT
C4
Energy supplier contact; close
d on release; bridge if no blocking inte
rval
Term
inals
OU
T1
Charge/discharge/m
ixer 1 closed
Leg
en
d:
Diverting valve for dom
estic hot water
A1
X20
X7-2
Lin-2
X8
-X6
X10-1
3
2
MZ
1/MIS
1N2
NT
C5
2
NT
C8
OU
T3
Miniature circuit-brea
ker, compressor, heat pum
p 1F
9
Controller board; A
ttention: I-max =
6A
/230VA
C
BU
P
F12
TA
Auxiliary circulation pum
p
-X3
-1
OU
T4
IN4
Heat pu
mp 2
HU
P
NTC3
1L3
F10
ZW
1
X7-1
OU
T6
NT
C2
1L2
circulation pump
Heat pu
mp 1
MA
1/MIS
3
GND8
NTC2
IN4
N
TB1
OUT3
3
FP
1
BWT
OUT6
N
MIS
ZU
P
12V
External return sensor
NTC7
IN2
LIN-1
N
A4
OUT4
IN5
M
L1
L2
TRL
L3
B
HU
P
GND7
GN
D-X
10
NTC8
L1
OUT1
EV
U
GND6
PE
NTC1
GND3
OUT2
L
IN1
NTC9
Cut out a
uxiliary heating
OUT8
A3
-X4
3
/ B
L1
N
GND2
Sensor m
ixing circuit 1
NTC5
NTC6
Heating circuit circulating pum
p
GND1
Miniature circuit-brea
ker, compressor, heat pum
p 2
OUT7
L1
-X5
-1-X
3-2
Pum
p for mixing circuit 1
OUT5
PE
L1
L2
F11
TB
1
IN3
External sensor
1N1
2
/ A
OU
T5
Safety tem
perature limiter for underfloor heating
, bridge if not available
1L1
A4
Charge/discharge/m
ixer 1 open
PE
Nam
e
X10
ST
B F
BH
1
X8
M
N
1~N/PE/230V/50Hz
X20
A1
-X5
-2
GND4
Lin-Bus distrib
utor circuit board
A2
PE
UK
83
1187
1
PE
FP
1
1~N/PE/230V/50Hz
1~N/PE/230V/50Hz
IN5
1
Sub-distribution unit intern
al installation
X10-2
am
ps
L3
GND5
ZIP
27.0
5.2
014
2
Achim
Pfleg
er
2/2
Achim
Pfleg
er0
1.04.2
014
Hydraulic m
odule 2
12
34
56
78
12
34
56
78 Bl vo
n An
z
Nam
e
Datu
m
Zusta
nd
Blatt-N
r.
Bea
rb.
Datu
mÄ
nde
rung
230V: LWD ... / HMD 2/… Terminal diagram
39Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
1L1
-X10
1L2
1L3
12
-Q5
/3.5
1N1
34
53
1
64
2
-E22
ZW
1
1N2
56
1N3
PE
L1L2
L3N
PE
-X8
L1L2
L3N
PE
L1L2
L3N
PE
-X8
L1L2
L3N
PE
1-X
02
34
LIN 1
/2.15LIN
3/2.15
LIN 2
/2.15
32
1
41
-K11
X8-1
3
3~N
/PE
/400V/50H
z
PE
2
3~N
/PE
/400V/50H
zP
E
4
PE
43
21
E22
Operating m
aterials
X8
UK
81
7400
Control
Pow
er supply aux. heating
K11
ZW
1
Unit co
nnection
Q5
Auxiliary heating
Contactor for auxiliary heating
3~N
/PE
/400V/50H
z
Function
40
0V
po
we
r su
pp
ly
1
X8
Leg
en
d:
X10
Cable
4
Pow
er supply compressor; right-hand rot. field is m
andatory!3~
N/P
E/400V
/50Hz
Pow
er supply, compressor output -->
exte
rnal unitLIN
bus
3~N
/PE
/400V/50H
z
X8-2
LIN
32
PE
27.0
5.2
014
1
Achim
Pfleg
er
1508580
1 - 1508590
1;
1/3
Achim
Pfleg
er1
9.05.2
011
Hydraulikm
odul HM
D 2 400V
_230V817400
12
34
56
78
910
1112
1314
1516
12
34
56
78
910
1112
1314
1516
-P
EP
014/2014
Bl vo
n An
z
Nam
e
Datu
m
Zusta
nd
Blatt-N
r.
Bea
rb.
Datu
mÄ
nde
rung
Circuit diagram 1/3 HMD 2/…
40 Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
1L1
-X10
1L2
1L3
12
1N1
34
53
1
64
2
-.E2
2Z
W1
1N2
56
1N3
PE
L1L2
L3N
PE
-X8
LN
PE
L1L2
L3N
PE
-X8
LN
PE
1-X
02
34
LIN
1/1.15
,/3.9
LIN
3/1.15
,/3.9
LIN
2/1.15
,/3.9
UK
81
7400
Distribution
box powe
r supply output compresso
r
LIN bus
PE
Cable
Pow
er supply, compressor output -->
exte
rnal unit
-K11
2
Pow
er supply aux. heating
Control
2
1~N
/PE
/230V/50H
z
X7-1
X7-2
PE
1~N
/PE
/230V/50H
z
1P
E
1
1~N
/PE
/230V/50H
z
1~N
/PE
/230V/50H
z2
Function
LIN
Q5
X10
1~N
/PE
/230V/50H
z
Contactor for auxiliary heating
2
K11
Auxiliary heating
-Q5
/3.5/3.5
23
0V
po
wer s
up
ply
E22
PE
X8
Unit co
nnection
1
ZW
1
Leg
en
d:
1
Operating m
aterials
X7
27.0
5.2
014
2
Achim
Pfleg
er
1508580
1 - 1508590
1;
2/3
Achim
Pfleg
er2
6.02.2
014
Hydraulikm
odul HM
D 2 400V
_230V817400
12
34
56
78
910
1112
1314
1516
12
34
56
78
910
1112
1314
1516
-P
EP
014/2014
Bl vo
n An
z
Nam
e
Datu
m
Zusta
nd
Blatt-N
r.
Bea
rb.
Datu
mÄ
nde
rung
HMD 2/… Circuit diagram 2/3
41Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
PE
NL
L-X
0
L
-X10
NN
PE
PE
L-X
0L
L
IN1
-X3-2
IN3
IN2
1413
-Q55
M1
brbl
PE
brblbk
-M4
HU
P 1
OUT1
-X3
-1
ϑ
-ST
B
A1
A2
-Q5
ZW
1
M1
brbl
PE
brblbk
-M5
HU
P 2
1
-X10
12V
GN
D
/BB
/AA
-X6
12
3P
E
LIN 3
/2.15LIN
2/2.15
LIN 1
/2.15
6-X
11
54
33-X
3
3-X
2
3-X
1
2222
1111
12
3P
E
AIN1
-X9yellow
white
Green
Brown
-B21
AGND1
AOUT1
AIN2
-X9yellow
white
Green
Brown
-B32
AGND2
AOUT2
ϑ
NTC6
-X5
-1
-R5L
TV
L 1
GND6
ϑ
NTC7
-X5
-2
-R6
R
TV
L 2
GND7
ϑ
NTC8
-X5-2
-R4
TR
L
GND8
NTC9
-R9
CW
GND9
12
/1.43
4/1.4
56
/1.414
134
Operating m
aterials
EV
U
X10
Contactor for auxiliary heating
ZW
1
Supply term
inals in switchbox of h
ydraulic mo
dule; N
/PE
distribution for external 230V
units
LIN
1
Return sensor
TV
L 1
HU
P 2
Q5
TR
L
Function
Leg
en
d:
R6
UK
81
7400
LIN
2
R4
br
B2
-K30
1~N/P
E/230V
/50Hz
TV
L 2
LIN distributor circuit boa
rd
Flow
sensor 1
EV
U
M4
Controller supply
Controller board; A
ttention: I-max =
6A/230V
AC
1~N
/PE
/230V/50H
z
ST
B
Heating pum
p 1
Energy supplier contact; closed on release; bridge if no blocking interval
CW
R9
Encoding resistor 19.6
kOhm
M5
Flow
sensor 2
X10
K30
-X20
B3
C
blH
UP
1
1
Flow
sensor 1
Safety tem
perature limiter, a
dditional heating
Heating pum
p 2
Flow
sensor 2
X20
R5
26.0
3.2
014
Ach
im P
fleger
3/3
Hydraulikm
odul HM
D 2 400V
_230V
12
34
56
78
910
1112
1314
1516
3
27.05.20
14
12
34
56
78
910
1112
1314
1516
Achim
Pfleg
er
ÄM
Zusta
nd
Index:
Bl vo
n A
nzÄ
nde
rung
Ursp
r.
Blatt-N
r.
Bea
rb.
Datu
mN
ame
Norm
Ers. für
Projekt:
Gepr.
AN
r.
Ers. durch
Datum
Circuit diagram 3/3 HMD 2/…
42 Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
43Subject to change without notice | 83055500cUK – Translation of the original operating manual | ait-deutschland GmbH
Item number 1 Item number 210060102 1006010210060202 1006010210060202 1006020210060902 1006010210060902 1006020210060902 1006090210060302 1006030210060402 1006030210060402 1006040210060502 1006050210060602 1006050210060602 1006060210060702 1006070210060802 1006070210060802 10060802
IIA1
ait-deutschland GmbHIndustrie Str. 393359 KasendorfGermany
Module
UK818192
Place, date:
Signature:
Designated position:TÜV-SÜDIndustrie Service GmbH (Nr.:0036)
Company:
EN 61000-3-2/-3-3EN ISO 12100-1/2 EN 55014-1/-2
Kasendorf, 24.07.2019
Jesper StannowHead of Heating Development
EC Directives EN..EN 349
EN 60529
Pressure equipment componentEN 14825
EN 60335-1/-2-40
EN ISO 13857
Category
2014/35/EU 813/20132014/30/EU 814/20132011/65/EG*2014/68/EU
EN 378
LWD 7050A/RX-HMD*LWD 7070A/RX-HMD*LWD 5050A/RSX-HMD*LWD 7050A/RSX-HMD*
Designation of the device(s)
LWD 5050A/RX-HMD*
100601H1002
100602H1402100609H1402100609H1602100609H1802100603H1002
15085801
LWD 7070A/RSX-HMD* 100608H1402
100604H1202100604H1402
EC Declaration of Conformity
150859011508590115085901
150859011508590115085901
150858011508580115085801150858011508580115085801
100605H1002100606H1202
confirms that the following designated device(s) as designed and marketed by us fulfill the standardized EC directives,the EC safety standards and the product-specific EC standards.In the event of modification of the device(s) without our approval, this declaration shall become invalid.
The undersigned
Heat Pump
15085801
LWD 5050A-HMD*
100606H1402100607H1002100608H1202
LWD 9090A-HMD*
LWD 7050A/SX-HMD*LWD 7070A/SX-HMD*
100602H1202
Unit model Item number 3Order number
15085801
LWD 7050A-HMD*LWD 7070A-HMD*LWD 9050A-HMD*LWD 9070A-HMD*
LWD 5050A/SX-HMD*
ait-deutschland GmbHIndustriestrasse 395359 Kasendorf, Germany
E [email protected] www.alpha-innotec.de
alpha innotec – an ait-deutschland GmbH brand
UK