HORIZONTAL PARIS INVE TE

i-PA

ENG

In RC Clima, we are not just offering a high-quality product, we also provide our costumers with a premium after sales and technical support

TOTA

L SU

PPORT

Technical support directly from RC Clima engineersCommisioning and maintenance programsOriginal spare parts

ENGIN

EERI

NG &

CUS

TOM

ISAT

ION

Engineered tailor-made solutionsGuidance to select the right option

TRAI

NIN

G

HVAC training and courses

Dedicated training on RC Clima units, commisioning and maintenance ope-rations

RC CLIMA AFTERSALES, 100% Technical support

The cooling and heating capacity cover from 10kW up to 30kW and are available in compact and split version. Fully flexible and with a wide range of options, the range i-PAR is an invisible solution ideal for buildings were outdoor units can not be placed outside.

The Inverter compressor makes it possible to precisely adjust the capacity of the equipment to the thermal demand of the installation, consuming only the electrical power needed at any time.

HORIZONTAL PAR INVE TE is an efficient and reliable solution for air handling purposes. The units are available in heat pump or cooling only for air conditioning of medium areas, such as manufacturing plants, warehouses, offices, supermarkets and shops.

The range has been designed for indoor installation and to be ducted to both the indoor area to be air conditioned and outside for heating and cooling rejection, ideal for ceiling applications.

ECOErP

on/off compressor

Inverter compressor

PRECISION, EFFICIENCY AND RELIABILITY

Inverter equipment is the most economical option when considering seasonal operating costs.

COMPRESSOR POWER %

TEMPERATURE

4

STANDARD FEATURES AND OPTIONS

Standard*Options

Galvanised sheet metal coated with an epoxy baked powder paint

Panel handlers for easy access

Thermo-acoustic fire resistant insulation foam

Compact and optimised design

• Customized design to meet special requirements

ENVE

LOPE

DC INVERTER Scroll Brushless compressors

Compressor discharge temperature protection

Intelligent oil management

• Compressors jacket for lower sound levelsCOM

PRES

SORS

Optimised and high efficiency coils manufactured from copper tube and aluminium fins

• Fins coating protection (Epoxy, Blygold©,…)

HEAT

EXC

HANG

ERS

VENTILA

TION High efficiency EC centrifugal fans in the indoor

and outdoor units for further efficiency and high external static pressure.

Constant Air Flow, flexibility to adapt to the installation pressure drop with the minimum input power maintaing always the required air flow

Low sound levels

In accordance with EN-60204-1

Door interlocking electric isolator

Phase rotation protection

Magnetothermal switch protections

Transformer

Sub circuit protection

Wired to the latest European standards and codes of practice

Soft start: very low starting intensity thanks to the Inverter compressor and EC fans

ELEC

TRIC

AL C

OM

PONE

NTS

Category G4 air filter

• Category M5, M6, F7, F8, F9 • Filter change pressure switch

AIR

FILT

RATION

REFR

IGER

ATIO

N CI

RCUI

T 1 refrigeration circuit

Inverter compressor

Electronic expansion valve

Filter dryer

Full operating charge of R410 refrigerant

Binder points

PID condensation control

4 way valve for heat pump mode

High pressure switch

High and low pressure transducer

ECOErP

High efficiency and ecodesign at your service

Horizontal i - PA

• Free cooling (based on temperature or enthalpy), of 2 dampersAH

ORR

OEN

ERGÉT

ICO

In accordance with EN-60204-1

Door interlocking electric isolator

Phase rotation protection

Magnetothermal switch protections

Transformer

Sub circuit protection

Wired to the latest European standards and codes of practice

Soft start: very low starting intensity thanks to the Inverter compressor and EC fans

1 refrigeration circuit

Inverter compressor

Electronic expansion valve

Filter dryer

Full operating charge of R410 refrigerant

Binder points

PID condensation control

4 way valve for heat pump mode

High pressure switch

High and low pressure transducer

Unity Software: Dedicated RC-CLIMA software

All parameters and alarms can be monitored from the display

Scan cycling of 40ms

Time zone programming

Data logging and alarms log

BMS port communication via Modbus RTU

User Terminal Th-Tune

EC fans controlled via Modbus

Dedicated cuting-edge technology controller

• BMS Communication cards available (Bacnet, Modbus, Ethernet) • pGD Graphic Display

SOFT

WAR

E &

CONT

ROL

• Low pressure hot water coil for additional heating

• Air quality sensors (VOC and CO2)

• Fire and smoke detector

OTH

ERS

TECHNICAL DATA*

Cooling capacity and input power at nominal conditions. Indoor temperature of DBT= 27ºC, WBT = 19ºC and outdoor temperature of DBT = 35ºC, in accordance with UNE-EN 14511 standard. Heating capacity and input power at nominal conditions. Indoor temperature of DBT = 20ºC, WBT = 15ºC max., And outdoor temperature of DBT = 7ºC, WBT = 6ºC, in accordance with UNE-EN 14511 standard.

** Sound pressure level values measured below the unit installed with ducts

The information in this document is subject to change without previous notification. RC Clima does not accept liability for any error or omission.

MODEL i - PAR018 i - PAR025Nominal Maximum Minimum Nominal Maximum Minimum

COOLING MODE

Total cooling capacity kW 18,6 21,0 12,0 24,5 28,0 15,7

Sensible cooling capacity kW 14,9 - - 19,2 - -

Input power in cooling kW 6,8 8,6 4,0 8,8 11,2 5,0

EER W/W 2,75 2,45 3,02 2,80 2,51 3,17Seasonal energy efficiency Ƞs,c % 149,7 171,6

HEATINGMODE

Nominal Maximum Minimum Nominal Maximum MinimumTotal heating capacity kW 19,0 22,7 11,0 24,6 29,6 14,3

Input power in heating kW 6,1 7,9 3,6 7,7 10,0 4,5

COP W/W 3,13 2,88 3,08 3,22 2,98 3,21

Seasonal energy efficiency Ƞs,h % 128,7 136,9

COMPRESSORSType of compressor Brushless DC Inverter

Nº of compressor ud 1 1

OUTDOOR FANFan type EC Centrifugal

Air flow m³/h 6.000 7.750

Static pressure Pa 160 246

INDOOR FANFan type EC Centrifugal

Air flow m³/h 3.800 4.500

Static pressure Pa 300 484

GENERAL DATAMains incoming supply 400V-III+N-50Hz

Refrigerant R410A

Sound pressure level ** dB(A) 56 56

OPERATING LIMITS

DIMENSIONS _Compact unit

DIMENSIONS _Split unit

MODE COOLING HEATING

INDOOR AIR DBT WBT DBT WBTMinimum 19ºC 14ºC 10ºC -Maxim 35ºC 24ºC 27ºC -

OUTDOOR AIR DBT WBT DBT WBTMinimum -10ºC - -10ºC -10ºCMaxim 48ºC - 24ºC 15ºC

i - PAR MODEL i - PAR018 i - PAR025

Width (W) mm 1750 1990

Depth (D) mm 1900 2057

Height (H) mm 635 667

i - PAR C MODEL i - PAR018 C i - PAR025 C

Width (W) mm 1740 1990

Depth (D) mm 1212 1334

Height (H) mm 635 667

i - PAR E MODEL i - PAR018 E i - PAR025 E

Width (W) mm 1728 1968

Depth (D) mm 767 802

Height (H) mm 635 667

H

D W

H

D

W

D

W

H

For off-limits operation, consult the RC Climate Engineering Department.

6

A SOLUTION FOR EACH CHALLENGE

ROOFTOP BARCELONAThe perfect compact solution for large areas

HORIZONTAL PARISThe invisible solution for indoor installation in ceilings with a ductwork

VERTICAL NEW YORKAn invisible solution for installation in basements and machinery rooms with a ductwork

AXIAL MADRIDCondensing outdoor unit to be matched with an indoor unit.

CONFIGURATIONSIndoor unit

CONFIGURATIONSOutdoor unit

I

I

I I

R

RR

A B

C D

R

R

I

R

I

R

I

R

I

1 2

3 4

R - Return airI - Supply air

High efficiency and ecodesign at your service

Horizontal i - PA

High efficiency and ecodesign at your service

Polígono Industrial SkolCarretera Batllòria, Nave E

17451, Sant Feliu de BuixalleuGirona, España

[email protected]

Polígono Industrial GaseransCalle Ter, Parcela 6A

17451, Sant Feliu de BuixalleuGirona, España

[email protected]

14.05.101.008 V00