general catalogue 2021 - rc clima

24
GENERAL CATALOGUE 2021 Heat Exchangers | Air Conditioning Units (air - air) Finned tube Heat Exchangers | Brazed Plate Heat Exchangers ALL YOU NEED IN HVAC | TAILOR-MADE QUALITY

Upload: others

Post on 21-Oct-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: GENERAL CATALOGUE 2021 - RC CLIMA

G E N E R A L C A T A L O G U E

2 0 2 1

Heat Exchangers | Air Condit ioning Units (air - air)

Finned tube Heat Exchangers | Brazed Plate Heat Exchangers

ALL YOU NEED IN HVAC | TAILOR-MADE QUALITY

Page 2: GENERAL CATALOGUE 2021 - RC CLIMA
Page 3: GENERAL CATALOGUE 2021 - RC CLIMA

MISSION | Quick manufacturing of high quality air conditioning machines and heat exchangers, in collaboration with our partners and giving them technical support.

VISION | To be a reference in the field thanks to our quality, dynamism and flexibility.

ALL YOU NEED IN HVACTAILOR-MADE QUALITY

FLEXIBILITYOur Technical Department makes custom designs,

covering the specific needs of each client.

DELIVERY TIME: 2 WEEKSOur production system allows us to offer a

delivery time of 2 weeks.

RC Clima Cerezo is a flexible and quick manufacturer of air conditioning equipment, heat exchangers and all you need in HVAC. that combines standard products with tailor-made products.

3

Page 4: GENERAL CATALOGUE 2021 - RC CLIMA

WATER COILS EVAPORATORS CONDENSERS

STAINLESS STEEL HEAT EXCHANGERS

FINNED TUBE HEAT EXCHANGERS FOR HIGH

TEMPERATURES AND PRESSURES

Customized manufacturing and supply of heat exchangers calculated, designed and built thinking about the specific needs of the client. Wide range of options that can be combined in each project.

HEAT EXCHANGERS

BRAZED PLATE HEAT EXCHANGERS

4

Page 5: GENERAL CATALOGUE 2021 - RC CLIMA

FINISHES

Epoxy(priming)

A pre-lacquered coating over the Al improves its durability.

Copper

Your best ally against corrosive envi-ronments, such as marine conditions.

Stainless steel

An ideal finish for naval industry or food and pharmaceutical facilities.

CERTIFICATIONS

ISO 9001

Quality, our fundamental purpo-se.

Quality dossiers

We prepare extensive quality dos-siers at clients request.

Welding

Lloyd’s Register Group

Blygold (covering)

It provides an optimal protection against corrosion, without affec-ting thermal transmission.

Heresite(covering)

The most effective protection against aggressive vapors or strongly saline atmospheres.

CONDENSATES TRAY

OPTIONAL

DROP SEPARATOR

Cataphoresis(painting)

The cathodic electrodeposition process provides the highest level of protection against corrosive agents. (see measurements)

Aqua Aero(covering)

It provides an optimal protection against corrosion, without affec-ting thermal transmission.

5

Page 6: GENERAL CATALOGUE 2021 - RC CLIMA

ø5/8ʼʼ

15 60

30

ø3/8ʼʼ

6,25 2521

,65

ø5/8ʼʼ

9, 8

34

5 3

GEOMETRIES

325

538

560

F38/I38

38 X 34 5/8” Material Thickness Fin pitch (mm.) Fin pitch (fpi.)

Tubes Copper 0,38 / 0,9 / 1,0

Fins Aluminium 0,11 / 0,18 2,0 – 4,2 13 – 6

Epoxy Aluminium 0,11 2,0 – 3,2 13 – 8

Copper 0,11 / 0,17 2,0 – 4,2 13 – 6

Frame Galvanized steel 1,5 / 2,0 / 3,0

AISI 304 & 316 1,5 / 2,0 / 3,0

Aluminium 1,5 / 2,0

60 X 30 5/8” Material Thickness Fin pitch (mm.) Fin pitch (fpi.)

Tubes Copper 0,38 / 0,9 / 1,0

Fins Aluminium 0,10 / 0,15 / 0,25 2,0 – 3,6 13 – 7

Epoxy Aluminium 0,10 2,0 – 3,0 13 – 8

Copper 0,10 2,0 – 3,0 13 – 8

Frame Galvanized steel 1,5 / 2,0 / 3,0

AISI 304 & 316 1,5 / 2,0 / 3,0

Aluminium 1,5 / 2,0

38 X 34 3/8” Material

Tubes Fe / AISI304 / AISI316

Fins Fe / Al / AISI304 / AISI316

Frame Fe / AISI304 / AISI316

25 X 21,65 3/8” Material Thickness Fin pitch (mm.) Fin pitch (fpi.)

Tubes Copper 0,28 / 0,4

Fins Aluminium 0,11 / 0,15 2,0 – 3,8 13 – 7

Epoxy Aluminium 0,11 2,0 – 3,2 13 – 8

Copper 0,10 2,0 – 3,1 13 – 8

Frame Galvanized steel 1,0 / 1,5 / 2,0

AISI 304 & 316 1,0 / 1,5

Aluminium 1,0 / 1,5

6

Page 7: GENERAL CATALOGUE 2021 - RC CLIMA

ENGINEERING

SOFT WARE

Intuitive and with a problem-solving approach, we have a software for coils calculation which has beencreated by a leading European supplier.

Download it in an "install format", or in a DLL format (integrable in an Air Handling Units software).

Each project becomes a “plug & play” design.

Get instant answers and calculations, always with the possibility to do a double check for you.

Improve reactivity and service of your engineering and commercial departments.

MECHANICAL TESTS

We submit the heat exchangers to vibration tests, through a highly experienced laboratory certified by ENAC, an accreditation recognized by countries such as Germany, Canada, China, USA, France, England or Japan, and approved by the Spanish Nuclear Power Plants Operators Association.

We also submit our 3D designs to earthquake resistance and fatigue testing. Our Technical Office is specialized in fields such as nuclear, military and naval. PNEUMATIC TESTS

All of our heat exchangers are validated through strict and specific quality and tightness controls, in accordance with Directive 2014 / 68 / EU (PED), applicable since July 20, 2016.

FINITE ELEMENTS

It is a method of calculating forces based on the division of a solid body into a mesh of smaller elements, connected by points known as nodules. These elements have movement restrictions and applied loads.

The finite elements calculation software shows the possible deformations of the original body, and that is how stresses are calculated.

7

Page 8: GENERAL CATALOGUE 2021 - RC CLIMA

BCN ROOFTOPS are compact units, heat pump or cold-only operation, designed to be installed outdoors on a flat surface (roofs, floors…), ready to be connected to the air conditioning ducts. Are designed to be used in commercial premises, malls, industrial buildings…

The entire BCN series includes the option of incorporating a highly efficient thermodynamic heat recovery unit that is integrated into the standard machine’s refrigeration unit, with no need to add an extra refrigerant circuit.

ROOFTOP BARCELONAAIR CONDITIONING UNITS

INVE TEThe BCN series, from 25 kW to 290 kW, covers a wide range of possibilities. Configurable in all areas, BCN rooftops respond to every market demand.

As standard BCN series use R-410A and, optionally, R-134a.

The Inverter compressor makes possible to precisely adjust the capacity of the equipment to the thermal demand of the installation, consuming only the necessary electrical power at any time.

OPTIONALLY: INVE TE

TECHNICAL DATA*

INVE TE

8

MODEL BCN025 i-BCN025 BCN035 i-BCN035 BCN045 i-BCN045 BCN050 BCN065 BCN085 BCN095 BCN125 BCN160

COOLING MODE

Total cooling capacity kW 24,5 24,3 35,6 36,3 44,6 43,0 47,4 64,7 79,2 91,0 120,3 165,9

Sensible cooling capacity kW 19,9 19,3 27,6 28,3 33,6 33,9 36,4 48,8 58,6 68,6 92,3 120,1

Input power in cooling kW 8,3 7,2 11,2 12,0 14,8 13,1 15,1 18,7 23,4 27,5 37,9 47,7

EER W/W 2,96 3,39 3,17 3,03 3,01 3,27 3,14 3,46 3,39 3,31 3,17 3,48

SEER W/W - 5,1 - 3,67 - 4,2 - - - - - -

Seasonal energy efficiency Ƞs,c % - 204 - 147 - 168 - - - - - -

HEATING MODE

Total heating capacity kW 26,3 25,1 37,4 37,2 47,2 44,8 49,5 65,64 84,4 92,2 126,9 172,6

Input power in heating kW 7,0 6,2 9,8 10,7 12,5 11,8 13,0 16,5 20,5 22,9 32,3 43,8

COP W/W 3,77 4,03 3,82 3,47 3,78 3,80 3,81 3,98 4,12 4,02 3,93 3,94

SCOP W/W - 3,48 - 4,43 - 3,68 - - - - - -

Seasonal energy efficiency Ƞs,c % - 136 - 174 - 144 - - - - - -

COMPRESSORS

Type of compressor Scroll

Brushless

DC Inverter Scroll

Brushless

DC Inverter Scroll

Brushless

DC Inverter Scroll Scroll Scroll Scroll Scroll Scroll

Nº of compressors ud 2 1 2 1 2 1 2 2 2 2 2 2

Nº of circuits ud 1 1 1 1 1 1 2 2 2 2 2 2

OUTDOOR FANS

Type AC axial Axial EC AC axial Axial EC AC axial Axial EC AC axial AC axial AC axial AC axial AC axial AC axial

Air flow m³/h 8.300 10.000 14.500 13.600 14.300 23.000 18.000 18.400 31.200 29.000 41.600 46.000

External static pressure Pa 50 96 50 19 60 184 55 55 50 60 50 62

INDOOR FANS

Type EC radial Radial EC EC radial Radial EC EC radial Radial EC EC radial EC radial EC radial EC radial EC radial EC radial

Air flow m³/h 4.500 5.000 6.200 8.500 8.000 11.500 9.500 10.500 13.000 15.400 24.000 26.000

External static pressure Pa 927 852 824 545 631 378 548 462 793 636 624 800

GENERAL DATA

Mains incoming supply 400V-III-50Hz x x x

Mains incoming supply 400V-III+N-50Hz x x x

Mains incoming supply 400V- 3ph -50Hz x x x x x x

Refrigerant R410A

Sound pressure level ** dB(A) 86,8 89,3 91,6

Page 9: GENERAL CATALOGUE 2021 - RC CLIMA

On/off compressor Inverter compressor

PRECISION, EFFICIENCY AND RELIABILITY

An inverter equipment is the most economical option when considering seasonal operating costs.

TEMPERATURE % COMPRESSOR PERFORMANCE

GENERAL CHARACTERISTICS

ROOFTOP BARCELONA

ENVELOPE

ON/OFF INVERTER

Galvanised sheet metal ✓ ✓

Anticorrosion treatment ✓ ✓

Polyester paint ✓ ✓

Compact and optimised design ✓ ✓

Thermo-acoustic fire resistant insulation foam ✓ ✓

Other levels of protection and custom finishes ● ●

HEAT EXCHANGERS

ON/OFF INVERTER

Expanded copper tube ✓ ✓

Aluminum fins ✓ ✓

Fins coating protection (Epoxi, Blygold©...) ● ●

ENERGY SAVINGS

ON/OFF INVERTER

Thermodynamic energy economizer ● ●

Free cooling (based on temperatura orenthalpy), of 2 or 3 dampers

● ●

AIR FILTRATION

ON/OFF INVERTER

G4 category air filter ✓ ✓

M5, M6, F7, F8, F9 category ● ●

Filter change pressure switch ● ●

VENTILATION

ON/OFF INVERTER

High Efficiency EC Radial Fans (indoor unit) ✓ ✓

2-speed AC axial fans (outdoor unit) ✓ -

High efficiency EC axial fans with PID condensation / evaporation control

● ✓

Low sound levels ✓ ✓

EC radial return fan ● ● ✓ ON/OFF included✓ Inverter included● Optional- Not available

COMPRESSORS

ON/OFF INVERTER

Hermetic Scroll compressors ✓ -

Scroll Brushless DC compressors - ✓

Smart software to keep compressor oil in perfect condition

- ✓

Compressors Crankcase heaters ✓ -

Compressor discharge temperature protection ✓ ✓

Compressors jacket for lower sound levels ● ●

Compressor soft start ● ✓

SOFTWARE & CONTROL

ON/OFF INVERTER

Unity software: dedicated RC Clima Cerezo software ✓ ✓

All parameters and alarms can be monitored fromthe display

✓ ✓

Next generation optimized controller ✓ ✓

Time zone programming ✓ ✓

EC fans controller ✓ ✓

BMS communication cards available (Bacnet, Modbus or Ethernet)

● ●

PGD graphic display ✓ ✓

9

Page 10: GENERAL CATALOGUE 2021 - RC CLIMA

CAPACITIES WITH THERMODYNAMIC RECOVERYCOOLING MODE

HEAT MODE

P

A

H

R

E

R

E

R

E

R E

R

E

RETURN AIR CONFIGURATIONFreecooling | 2 dampers

F G H

I J

R

E

X

R

E

X

RETURN AIR CONFIGURATIONFreecooling | 3 dampers + return fan

K L

RETURN AIR CONFIGURATIONThermodynamic energy economizer

R

E

X

R

X

E

M N

I

I

I I

SUPPLY AIR CONFIGURATIONSupply air

1 2 3 4

RETURN AIR CONFIGURATIONStandard return

R

R

R

R

R

A B C

D E

STANDARD EQUIPMENT DIMENSIONS

ROOFTOP BARCELONA

I - ImpulsionR - ReturnX - Exhaust airE - Fresh air

ELECTRICAL COMPONENTS

ON/OFF INVERTER

In accordance with EN-60204-1 ✓ ✓

Door interlocking electric isolator ✓ ✓

Sequence control and phase failure ✓ ✓

Overload and short circuit protection for all motors in the unit

✓ ✓

Control circuit transformer ✓ ✓

Magnetothermal protection ● ●

Energy manager to monitor energy consumption ● ●

OTHERS

ON/OFF INVERTER

Electric heating (1 or 2 stages) for additional heating ● ●

Low pressure hot wáter coil for additional heating ● ●

Air quality sensors (VOC and CO2) ● ●

Smoke detector ● ●

Fire detector ● ●

BCN MODEL BCN025 BCN035 BCN045 BCN050 BCN065 BCN085 BCN095 BCN125 BCN160

Width (W) mm 1470 1470 1470 2000 2000 2000 2000 2340 2340

Depth (D) mm 2860 2860 2860 3250 3250 3850 3850 4370 4370

Height (H) mm 1700 1700 1700 1500 1500 1780 1780 1900 1900

DATA / MODEL BCN025 BCN035 BCN045 BCN050 BCN065 BCN085 BCN095 BCN125 BCN160

60% air renewal

Cooling capacity 33,4 48,0 56,8 64,5 86,1 112,1 125,4 169,2 207,0

EER 3,75 3,46 3,36 3,67 3,69 3,78 3,66 3,63 3,38

DATA / MODEL BCN025 BCN035 BCN045 BCN050 BCN065 BCN085 BCN095 BCN125 BCN160

60% air renewal

Heating capacity 31,9 46,0 54,5 61,2 81,9 106,1 119,0 161,5 196,5

COP 3,86 3,54 3,58 3,77 3,77 3,89 3,81 3,85 3,57

REFRIGERATION CIRCUIT

ON/OFF INVERTER

1 refrigeration circuit ✓ ✓

2 refrigeration circuits ✓ -

Inverter compressor - ✓

Tandem of scroll compressor per circuit ✓ -

Thermostatic expansión valves (TEV) ✓ -

Electronic expansion valve - ✓

Filter dryer ✓ ✓

R-410A refrigerant full operating charge ✓ ✓

Binder points ✓ ✓

Non-return valves ✓ -

4 way valve for heat pump mode ✓ ✓

High and low pressure switch ✓ ✓

10

Page 11: GENERAL CATALOGUE 2021 - RC CLIMA

MODEL i - PAR018 i - PAR025

Nominal Maximum Minimum Nominal Maximum Minimum

COOLING

MODE

Total cooling capacity kW 18,6 21,0 12,0 24,5 28,0 15,7

Sensible cooling capacity kW 14,9 - - 19,2 - -

Input power in cooling kW 6,8 8,6 4,0 8,8 11,2 5,0

EER W/W 2,75 2,45 3,02 2,80 2,51 3,17

Seasonal energy efficiency Ƞs,c % 149,7 - - 171,6 - -

HEATING

MODE

Nominal Maximum Minimum Nominal Maximum Minimum

Total heating capacity kW 19,0 22,7 11,0 24,6 29,6 14,3

Input power in heating kW 6,1 7,9 3,6 7,7 10,0 4,5

COP W/W 3,13 2,88 3,08 3,22 2,98 3,21

Seasonal energy efficiency Ƞs,h % 128,7 - - 136,9 - -

COMPRESSORS

Type of compressor Brushless DC Inverter

Nº of compressor ud 1 1

OUTDOOR FAN

Fan type EC Centrifugal

Air flow m³/h 6.000 7.750

Static pressure Pa 160 246

INDOOR FAN

Fan type EC Centrifugal

Air flow m³/h 3.800 4.500

Static pressure Pa 300 484

GENERAL DATA

Mains incoming supply 400V-III+N-50Hz

Refrigerant R410A

Sound pressure level ** dB(A) 56 56

INVE TE

HORIZONTAL PARIS

High-efficiency air conditioning units with heat pump or cold-only operation, for medium-capacity places such as shops, industries, offices or supermarkets.

These horizontal units are designed to be installed inside buildings, usually in false ceilings, and to be coupled to a network of ducts to the interior (area to be air conditioned) and to the exterior (heat dissipation).

TECHNICAL DATA*

INVE TE

INVE TE

11

Page 12: GENERAL CATALOGUE 2021 - RC CLIMA

GENERAL CHARACTERISTICS

HORIZONTAL PARIS

ENVELOPE

INVERTER OptionalINVERTER

Galvanised sheet metal ✓

Anticorrosion treatment ✓

Polyester paint ✓

Compact and optimised design ✓

Thermo-acoustic fire resistant insulation foam✓

Other levels of protection and custom finishes ●

COMPRESSORS

INVERTER OptionalINVERTER

Scroll Brushless DC compressors ✓

Smart software to keep compressor oil in perfect condition

Compressor discharge temperature protection ✓

Compressors jacket for lower sound levels ●

HEAT EXCHANGERS

INVERTER OptionalINVERTER

Expanded copper tube ✓

Aluminum fins ✓

Fins coating protection (Epoxi, Blygold©...) ●

ENERGY SAVINGS

INVERTER OptionalINVERTER

Free cooling (based on temperatura orenthalpy), 2 dampers

AIR FILTRATION

INVERTER OptionalINVERTER

G4 category air filter ✓

M5, M6, F7, F8, F9 category ●

Filter change pressure switch ●REFRIGERATION CIRCUIT

INVERTER OptionalINVERTER

1 refrigeration circuit ✓

INVERTER Compressor ✓

Electronic expansion valve ✓

Filter dryer ✓

R-410A refrigerant full operating charge – compact units ✓

R-410A refrigerant full operating charge – split units ●

Binder points ✓

PID condensation control ✓

4 way valve for heat pump mode ✓

High and low pressure switch ✓

Transducer for high and low pressure ✓

VENTILATION

INVERTER OptionalINVERTER

Centrifugal EC fans for indoor and outdoor unit ✓

Low sound levels ✓

High efficiency thanks to EC technology ✓

Maximum air flow with minimum noise level ✓

ELECTRICAL COMPONENTS

INVERTER OptionalINVERTER

In accordance with EN-60204-1 ✓

Door interlocking electric isolator ✓

Sequence control and phase failure ✓

Overload and short circuit protection for all motors in the unit

Control circuit transformer ✓

Energy manager to monitor energy consumption ●

OTHERS

INVERTER OptionalINVERTER

Electric heating (1 or 2 stages) for additional heating ●

Low pressure hot wáter coil for additional heating ●

Air quality sensors (VOC and CO2) ●

Smoke detector ●

Fire detector ●✓ INVERTER● optional INVERTER

SOFTWARE & CONTROL

INVERTER OptionalINVERTER

Unity software: dedicated RC Clima Cerezo software ✓

All parameters and alarms can be monitored fromthe display

Next generation optimized controller ✓

Time zone programming ✓

EC fans controlled via Modbus ✓

BMS communication cards available (Bacnet, Modbus or Ethernet)

PGD graphic display ✓

12

Page 13: GENERAL CATALOGUE 2021 - RC CLIMA

A

P

H

A

P

H

AP

H

COMPACT UNIT DIMENSIONS SPLIT UNIT DIMENSIONS

CONFIGURATIONSIndoor unit

CONFIGURATIONSOutdoor unit

I

I

I I

R

RR

1 2

3 4

R

R

I

R

I

R

I

R

I

A B

C D

HORIZONTAL PARIS

I - ImpulsionR - Return

i - PAR MODEL i - PAR018 i - PAR025

Width (W) mm 1750 1990

Depth (D) mm 1900 2057

Height (H) mm 635 667

i - PAR C MODEL i - PAR018 C i - PAR025 C

Width (W) mm 1740 1990

Depth (D) mm 1212 1334

Height (H) mm 635 667

i - PAR E MODEL i - PAR018 E i - PAR025 E

Width (W) mm 1728 1968

Depth (D) mm 767 802

Height (H) mm 635 667

The i-PAR equipment is delivered in compact format, with the possibility of being splitted on site by the end-user.

13

Page 14: GENERAL CATALOGUE 2021 - RC CLIMA

VERTICAL NEW YORK

Highly efficient air conditioning units with heat pump or cold-only operation for medium and high capacity applications, such as supermarkets, leisure areas, shops, production plants, offices or malls.

These vertical units are designed to be installed inside buildings, normally in engine rooms, and to be joined to a network of ducts inside (area to be air-conditioned) and outside (heat dissipation).

INVE TE

GENERAL CHARACTERISTICS

TECHNICAL DATA*

INVE TE

HEAT EXCHANGERS

ON/OFF INVERTER

Expanded copper tube ✓ ✓

Aluminum fins ✓ ✓

Fins coating protection (Epoxi, Blygold©...) ● ●

ENERGY SAVINGS

ON/OFF INVERTER

Free cooling (based on temperatura or enthalpy), of2 or 3 dampers

● ●

Thermodynamic energy economizer ● ●

MODEL NYC020 NYC025 i-NYC025 NYC035 i-NYC035 NYC045 i-NYC045 NYC050 NYC065

COOLING MODE

Total cooling capacity kW 21,8 25,5 22,9 36,5 36,3 43,1 43,0 49,0 65,4

Sensible cooling capacity kW 7,0 8,4 17,9 10,7 28,3 13,9 32,3 13,7 19,3

Input power in cooling kW 7,0 8,4 8,9 10,7 12,0 13,9 13,0 13,7 19,3

EER W/W 3,10 3,03 2,58 3,41 3,03 3,10 3,30 3,57 3,40

SER - - 3,49 - 3,67 - 4,66 - -

Seasonal energy efficiency Ƞs,c - - 140 - 147 - 186 - -

HEATING MODE

Total heating capacity kW 21,4 24,9 23,5 36,0 37,2 42,8 44,1 48,0 64,1

Input power in heating kW 6,6 7,8 8,0 10,0 10,7 12,7 11,5 12,6 18,0

COP W/W 3,26 3,19 2,94 3,60 3,47 3,35 3,83 3,80 3,57

Seasonal energy efficiency Ƞs,h - - 4,17 - 4,43 - 4,85 - -

Total cooling capacity - - 164 - 174 - 191 - -

COMPRESSORS

Type of compressor Scroll Scroll Scoll Inverter DC Scroll Scoll Inverter DC Scroll Scoll Inverter DC Scroll Scroll

Nº of compressor ud 2 2 1 2 1 2 1 2 2

Nº of circuits ud 1 1 1 1 1 1 1 2 2

OUTDOOR FAN

Fan type EC Centrifugal EC Centrifugal EC Radial EC Centrifugal EC Radial EC Centrifugal EC Radial EC Centrifugal EC Centrifugal

Air flow m³/h 7.100 7.600 8.000 10.500 11.600 13.000 14.000 14.800 18.400

Static pressure Pa 412 276 874 167 290 531 470 377 313

INDOOR FAN

Fan type EC Centrifugal

Air flow m³/h 4.000 4.800 5.000 7.000 7.500 7.900 7.000 9.700 12.000

Static pressure Pa 616 437 412 178 257 636

GENERAL DATA

Mains incoming supply 400V-III+N-50Hz x x x x x x

Mains incoming supply 400V-III-50Hz x x x

Refrigerant R410A

Sound pressure level dB(A) 95,2 97,1 92,6

14

Page 15: GENERAL CATALOGUE 2021 - RC CLIMA

VERTICAL NEW YORK

ENVELOPE

ON/OFF INVERTER

Galvanised sheet metal ✓ ✓

Anticorrosion treatment ✓ ✓

Polyester paint ✓ ✓

Compact and optimised design ✓ ✓

Thermo-acoustic fire resistant insulation foam ✓ ✓

handles built into the panels ✓ ✓

Other levels of protection and custom finishes ● ●

AIR FILTRATION

ON/OFF INVERTER

G4 category air filter ✓ ✓

M5, M6, F7, F8, F9 category ● ●

Filter change pressure switch ● ●

VENTILATION

ON/OFF INVERTER

EC centrifugal fans (indoor unit) ✓ ✓

EC centrifugal or radial fans (outdoor unit) - ✓

Low sound levels ✓ ✓

High efficiency ✓ ✓

Maximum air flow with minimum noise level ✓ ✓

Centrifugal AC fans in indoor and outdoor unit ● -

Return fan module using EC fans or transmission by pulleys and belts. ● -ELECTRICAL COMPONENTS

ON/OFF INVERTER

In accordance with EN-60204-1 ✓ ✓

Door interlocking electric isolator ✓ ✓

Sequence control and phase failure ✓ ✓

Overload and short circuit protection for all motors in the unit

✓ ✓

Control circuit transformer ✓ ✓

Magnetothermal protection ● ●

Energy manager to monitor energy consumption ● ●

OTHERS

ON/OFF INVERTER

Electric heating (1 or 2 stages) for additional heating ● ●

Low pressure hot wáter coil for additional heating ● ●

Air quality sensors (VOC and CO2) ● ●

Smoke detector ● ●

Fire detector ● ●

✓ ON/OFF included✓ Inverter included● Optional- Not available

COMPRESSORS

ON/OFF INVERTER

Hermetic Scroll compressors ✓ -

Scroll Brushless DC compressors - ✓

Smart software to keep compressor oil in perfect condition

✓ ✓

Compressors Crankcase heaters ✓ -

Compressor discharge temperature protection ✓ ✓

Compressors jacket for lower sound levels ● ●

Compressor soft start ● ✓

SOFTWARE & CONTROL

ON/OFF INVERTER

Unity software: dedicated RC Clima Cerezo software ✓ ✓

All parameters and alarms can be monitored fromthe display

✓ ✓

Next generation optimized controller ✓ ✓

40ms. scan cicles ✓ ✓

Time zone programming ✓ ✓

BMS port communication via Modbus RTU ✓ ✓

Variable storage (data-logging) in the controller itself for later export and monitoring

✓ ✓

EC fans controlled via Modbus ✓ ✓

Th-tune user terminal ✓ ✓

BMS communication cards available (Bacnet, Modbus or Ethernet)

● ●

PGD graphic display ● ●

REFRIGERATION CIRCUIT

ON/OFF INVERTER

1 refrigeration circuit ✓ ✓

2 refrigeration circuits ✓ -

Inverter Compressor - ✓

Tandem of scroll compressor per circuit ✓ -

Thermostatic expansión valves (TEV) ✓ -

Electronic expansion valve - ✓

Filter dryer ✓ ✓

R-410A refrigerant full operating charge ✓ ✓

Binder points ✓ ✓

Non-return valves ✓ -

4 way valve for heat pump mode ✓ ✓

High and low pressure switch ✓ ✓

15

Page 16: GENERAL CATALOGUE 2021 - RC CLIMA

CONFIGURATIONSIndoor unit

CONFIGURATIONSOutdoor unit

I

R

1

I

R

2*

R

I

3*

I

R

4I

R

C**

I

R

B

R

I

A

I - ImpulsionR - Return

*Only for compact units** Only for split units

COMPACT UNIT DIMENSIONS

SPLIT UNIT DIMENSIONS

VERTICAL NEW YORK

NYC MODEL NYC020 NYC025 NYC035 NYC045 NYC050 NYC065

Width (W) mm 1480 1480 1780 1780 2700 2700

Depth (D) mm 884 884 941 941 970 970

Height (H) mm 1480 1480 2395 2395 2400 2400

NYC MODEL - E NYC020 NYC025 NYC035 NYC045 NYC050 NYC065

Width (W) mm 1480 1480 1780 1780 2700 2700

Depth (D) mm 880 880 944 944 970 970

Height (H) mm 755 755 835 835 850 850

NYC MODEL - C NYC020 NYC025 NYC035 NYC045 NYC050 NYC065

Width (W) mm 1480 1480 1780 1780 2700 2700

Depth (D) mm 858 858 922 922 970 970

Height (H) mm 1350 1350 1675 1675 1630 1630

16

Page 17: GENERAL CATALOGUE 2021 - RC CLIMA

AXIAL MADRID

Efficient and reliable condensig unit for air handling purposes, available in heat pump or cold-only operation. The units are designed to be installed outdoor and connected to an indoor unit.

Axial MAD is a perfect solution for medium and large areas, such as manufacturing plants, malls, supermarkets…

TECHNICAL DATA*

INVE TE

INVE TE

MODEL MAD025 i-MAD025 MAD035 i-MAD035 MAD045 i-MAD045 MAD050 MAD065

COOLING MODE

Total cooling capacity kW 25,5 23,9 36.5 36,5 43,1 43,0 49,0 65,4

Sensible cooling capacity 19,5 18,5 28,0 28,3 34,0 32,9 38,9 51,9

Input power in cooling kW 8,2 7,5 12,8 12,1 15,4 13,0 15,9 21,5

EER W/W 3,12 3,18 2,85 3,01 2,80 3,30 3,08 3,04

SEER W/W - 4,49 - 3,67 - 4,2 - -

Seasonal energy efficiency Ƞs,c % - 180 - 147 - 170 - -

HEATING MODE

Total heating capacity kW 24,9 24,5 36,0 37,4 42,8 44,6 48,0 64,1

Input power in heating kW 7,6 6,3 12,1 10,9 14,2 11,6 14,8 20,2

COP W/W 3,29 3,88 2,97 3,43 3,00 3,84 3,23 3,17

Seasonal energy efficiency Ƞs,h - 3,84 - 4,43 - 4,15 - -

Total cooling capacity - 151 - 174 - 171 - -

COMPRESSORS

Type of compressor Scroll ScrollInverter DC Scroll Scroll

Inverter DC Scroll ScrollInverter DC Scroll Scroll

Nº of compressor ud 2 1 2 1 2 1 2 2

Nº of circuits ud 1 1 1 1 1 1 1 2

OUTDOOR FAN

Fan type Axial AC Axial EC Axial AC Axial EC Axial AC Axial EC Axial AC Axial AC

Air flow m³/h 8.300 10.000 14.500 12.000 14.300 13.600 18.000 18.400

Static pressure Pa 50 96 50 40 60 19 55 55

INDOOR FAN

Fan type EC Centrifugal

Air flow m³/h 4.800 5.000 7.000 7.500 7.900 7.000 9.700 12.000

Static pressure Pa 437 412 178 257 636

GENERAL DATA

Mains incoming supply 400V-III+N-50Hz x x x x x

Mains incoming supply 400V-III-50Hz x x x

Refrigerant R410A

Sound pressure level dB(A) 95,2 97,1 92,6

17

Page 18: GENERAL CATALOGUE 2021 - RC CLIMA

AXIAL MADRID

GENERAL CHARACTERISTICS

ENVELOPE

ON/OFF INVERTER

Galvanised sheet metal ✓ ✓

Anticorrosion treatment ✓ ✓

Polyester paint ✓ ✓

Compact and optimised design ✓ ✓

Thermo-acoustic fire resistant insulation foam ✓ ✓

Other levels of protection and custom finishes ● ●

COMPRESSORS

ON/OFF INVERTER

Hermetic Scroll compressors ✓ -

Scroll Brushless DC compressors - ✓

Smart software to keep compressor oil in perfect condition

✓ ✓

Compressors Crankcase heaters ✓ -

Compressor discharge temperature protection ✓ ✓

Compressors jacket for lower sound levels ● ●

Compressor soft start ● ✓HEAT EXCHANGERS

ON/OFF INVERTER

Expanded copper tube ✓ ✓

Aluminum fins ✓ ✓

Fins coating protection (Epoxi, Blygold©...) ● ●

ENERGY SAVINGS

ON/OFF INVERTER

Thermodynamic energy economizer ● ●

Free cooling (based on temperatura orenthalpy), of 2 or 3 dampers

● ●

AIR FILTRATION

ON/OFF INVERTER

G4 category air filter ✓ ✓

M5, M6, F7, F8, F9 category ● ●

Filter change pressure switch ● ●

VENTILATION

ON/OFF INVERTER

High Efficiency EC Radial Fans (Indoor Unit) ✓ ✓

2-speed AC axial fans (outdoor unit) ✓ -

High efficiency EC axial fans with PID condensation / evaporation control

● ✓

Low sound levels ✓ ✓

EC radial return fan ● ●

OTHERS

ON/OFF INVERTER

Electric heating (1 or 2 stages) for additional heating ● ●

Low pressure hot wáter coil for additional heating ● ●

Air quality sensors (VOC and CO2) ● ●

Smoke detector ● ●

Fire detector ● ●

✓ ON/OFF included✓ Inverter included● Optional- Not available

REFRIGERATION CIRCUIT

ON/OFF INVERTER

1 refrigeration circuit ✓ ✓

2 refrigeration circuits ✓ -

Inverter compressor - ✓

Tandem of scroll compressor per circuit ✓ -

Thermostatic expansion valves (TEV) ✓ -

Electronic expansion valve ● ✓

Filter dryer ✓ ✓

R-410A refrigerant full operating charge ✓ ✓

Binder points ✓ ✓

Non-return valves ✓ -

4 way valve for heat pump mode ✓ ✓

High and low pressure switch ✓ ✓

SOFTWARE & CONTROL

ON/OFF INVERTER

Unity software: dedicated RC Clima Cerezo software ✓ ✓

All parameters and alarms can be monitored fromthe display

✓ ✓

Next generation optimized controller ✓ ✓

Time zone programming ✓ ✓

EC fans controller ✓ ✓

BMS communication cards available (Bacnet, Modbus or Ethernet)

● ●

PGD graphic display ✓ ✓

ELECTRICAL COMPONENTS

ON/OFF INVERTER

In accordance with EN-60204-1 ✓ ✓

Door interlocking electric isolator ✓ ✓

Sequence control and phase failure ✓ ✓

Overload and short circuit protection for all motors in the unit

✓ ✓

Control circuit transformer ✓ ✓

Magnetothermal protection ● ●

Energy manager to monitor energy consumption ● ●

18

Page 19: GENERAL CATALOGUE 2021 - RC CLIMA

CONDENSING UNIT DIMENSIONS

H

A

P

A

P

H

EVAPORATING UNIT DIMENSIONSVertical NYC

AXIAL MADRID

OUTDOOR UNIT CONFIGURATIONSCondensing unit

NYC INDOOR UNIT CONFIGURATIONSEvaporating unit

I

I

R

R

1 2

A

* CAPACITY AND POWER IN ARI CONDITIONS

Cooling power at nominal conditions of internal temperature of DBT= 27ºC, WBT = 19ºC and an external temperature of DBT = 35ºC, according to UNE-EN 14511 standard.Heating power at nominal internal temperature conditions of DBT = 20ºC, WBT = 15ºC max., and an external temperature of DBT = 7ºC, WBT = 6ºC, according to UNE-EN 14511 standard.

I - ImpulsionR - Return

MAD – C MODEL MAD025 MAD035 MAD045 MAD050 MAD065

Width (W) mm 1470 1470 1470 2000 2000

Depth (D) mm 1000 1000 1000 1380 1380

Height (H) mm 1700 1700 1700 1500 1500

NYC – E MODEL NYC020 - E NYC025 - E NYC035 - E NYC045 - E NYC050 - E NYC065 - E

Width (W) mm 1480 1480 1780 1780 2700 2700

Depth (D) mm 880 880 944 944 970 970

Height (H) mm 755 755 835 835 850 850

19

Page 20: GENERAL CATALOGUE 2021 - RC CLIMA

DRYCOOLER LONDON

AIR CONDENSER RIO

HVAC SETSATHENS

Drycoolers are an ideal solution to operate with water-cooled chillers and in industrial processes.

Casing made of galvanized sheet steel with anticorrosion treatment and oven-dried polyester paint.

From 1 to 8 fans

EC or AC axial fans.

Coils of copper tubes and aluminum fins. Other anticorrosive materials and treatments available

Optional configuration to operate with high temperature water.

Low noise level

Customizable design for special projects

Casing made of galvanized sheet steel with anticorrosion treatment and oven-dried polyester paint.

From 1 to 8 fans

EC or AC axial fans

Coils of copper tubes and aluminum fins. Other anticorrosive materials and treatments available.

Optional pressure transducer

Low noise level

Customizable design for special projects

Remote air condensers for direct expansion units

Casing made of galvanized sheet steel.

To be coupled to circular or rectangular duct networks.

Standard heat exchanger made of copper tubes and aluminum fins. Other anticorrosive materials and treatments available

From 5 to 60 kW

Stainless steel condensation tray and drain connections

Optional oven-dried polyester paint

HVAC sets to be coupled to the air conditioning duct network

20

Page 21: GENERAL CATALOGUE 2021 - RC CLIMA

TOTA

L SU

PPO

RT

ENG

INEE

RIN

G

AND

FLE

XIBI

LITY

TRAI

NIN

G

Factory technical service

Commissioning and maintenance

Spare parts available

Special equipment and tailor-made solutionsAdvice to choose the best option

HVAC Technical Courses

Training for installation, commis-sioning and maintenance of air conditioning equipment

APPLICATIONS

TECHNICAL SUPPORT

RC CLIMA CEREZO TECHNICAL SUPPORT, WE ARE HERE FOR YOU.

AXIAL MADRIDCondensing outdoor unit to be matched with an indoor unit.

ROOFTOP BARCELONAThe perfect compact solution for large areas

HORIZONTAL PARISThe invisible solution for indoor installation in ceilings with a ductwork

VERTICAL NEW YORKAn invisible solution for installation in basements and machinery rooms with a ductwork

21

Page 22: GENERAL CATALOGUE 2021 - RC CLIMA

ECOErP INVE TE

Privileged with our environment, surrounded by a natural setting such as the Montseny Natural Park, north of Barcelona, we are committed to the sustainable development of the sector.

We innovate with highly efficient components, such as Inverter compressors and EC fans, for greater precision and comfort and to consume only the electrical power strictly necessary at all times.

We use ozone-friendly and low-GWP refrigerants.

We offer solutions with free cooling or heat recuperators, always looking for the most sustainable solution.

Energy savings drastically reduce equipment operating costs and make us the most profitable option.

The data included in this document are not binding and may be subject to change without obligation of prior notice by RC Clima Cerezo. Similarly, the images shown in this document may not match the product to be delivered since they may be subject to change.

GREEN COMMITMENT

22

Page 23: GENERAL CATALOGUE 2021 - RC CLIMA

Temperature and humidity control

Tests from -6ºC to + 55ºC

Overall dimensions: 12 m. x 5 m.

Flow and pressure measurement of air flows

2 test chambers, outdoor and indoor

Specialized personnel to carry out air conditioning and industrial refrigeration tests

In our facilities we have a climatic chamber to test your air conditioning equipment.

23

Page 24: GENERAL CATALOGUE 2021 - RC CLIMA

Polígon Industrial GaseransCarrer Ter, Parcel·la 6A

17451, Sant Feliu de BuixalleuGirona, Espanya

+34 972 86 57 [email protected]