yokogawa electric corporation solution marketing gr., international business headquarters copyright...
TRANSCRIPT
Yokogawa Electric Corporation
Solution Marketing Gr., International Business Headquarters Copyright © Yokogawa Electric CorporationApril 3, 2003-Rev2
Remote Desktop
April 3, 2003
ISD-MASP-S03005 Page.2
Solution Marketing Gr., International Business Headquarters Copyright © Yokogawa Electric CorporationApril 3, 2003-Rev2
CS1000/3000 General Information
ISD-MASP-S03005 Page.3
Solution Marketing Gr., International Business Headquarters Copyright © Yokogawa Electric CorporationApril 3, 2003-Rev2
World first Windows XP Support
CS1000/3000 works on Windows XP.– The world-first Windows XP compliant
system.
CS1000/3000 can work also on Windows2000.– If you would like to use CS1000/3000 on the
latest Windows technology, please adopt Windows XP.
– If you have already been using CS1000/3000 with R3.01 or R3.02, you can do revision up to R3.03 without changing OS from Windows2000.
Yokogawa always catches up with the latest Operating System. We keep the promise to give customers
“Peace of mind” for a long time !
ISD-MASP-S03005 Page.4
Solution Marketing Gr., International Business Headquarters Copyright © Yokogawa Electric CorporationApril 3, 2003-Rev2
Remote Monitoring and Operation
Remote DesktopWeb MonitoringWide Area Connection
ISD-MASP-S03005 Page.5
Solution Marketing Gr., International Business Headquarters Copyright © Yokogawa Electric CorporationApril 3, 2003-Rev2
Remote Desktop PC
Remote Login
ISD-MASP-S03005 Page.6
Solution Marketing Gr., International Business Headquarters Copyright © Yokogawa Electric CorporationApril 3, 2003-Rev2
Remote Operation / Engineering
Vnet
Public li
ne
Remote Monitoring
Remote Engineering
Remote Operation
Dial-up
Unmanned sites
EthernetOperation/Engineering is available without going in front of PC’s connected on Vnet.
ISD-MASP-S03005 Page.7
Solution Marketing Gr., International Business Headquarters Copyright © Yokogawa Electric CorporationApril 3, 2003-Rev2
Remote Assistance
Public lineRemote Monitoring
Dial-up
Vnet
Sites
Trouble !
•Skilled operators or Chief operators needs not always be in CCR.
•They can also be abroad.•Alarm is notified to his/her remote monitoring screen, which is same as that of CCR.
•Skilled operators or chief operators can advise on the phone to general operators with referring to the display.
ISD-MASP-S03005 Page.8
Solution Marketing Gr., International Business Headquarters Copyright © Yokogawa Electric CorporationApril 3, 2003-Rev2
How to realize remote HMI solutions?
Remote Desktop function, one of Windows XP standard functions, enables to realize these solutions.– The screen image of a PC is displayed on
the other PCs, connected on Ethernet.– You can operate (mouse/keyboard) a
remote PC from the other PC connected on Ethernet.
No extra software, no 3’rd party software is needed.
ISD-MASP-S03005 Page.9
Solution Marketing Gr., International Business Headquarters Copyright © Yokogawa Electric CorporationApril 3, 2003-Rev2
Web Monitoring
Ethernet
HIS
FCS
Control Bus
Dial-up Internet Connection
Graphic windowstrend windows, ITV windows
Plant monitoring on a business trip, at home, at maintenance office, etc. using Web Browser
Web Server
HIS graphic/trend windows are converted into HTML files and Java Applets
ISD-MASP-S03005 Page.10
Solution Marketing Gr., International Business Headquarters Copyright © Yokogawa Electric CorporationApril 3, 2003-Rev2
Wide Area Connection
DSU (Digital Service Unit)
DSU
DSU
DSU
DSU
Communication Band
Ethernet
V net
Ethernet
V netV net
Ethernet
Onshore Offshore
Center Domain Local Domain
HIS HIS
FCS
CGW
FCS
CGW
FCSFCS
HIS HIS
ISD-MASP-S03005 Page.11
Solution Marketing Gr., International Business Headquarters Copyright © Yokogawa Electric CorporationApril 3, 2003-Rev2
Comparison with other remote Solutions
Remote Desktop PC Anywhere Wide area CGW
Server XP Professional95/98/Me/NT/2000/XP
-
Client 95/98/Me/NT/2000/XP/CE
95/98/Me/NT/2000/XP -
Color 24bits full color 24bits full color 24bits full color
CENTUMAlarm Sound
Available N/A Available
Printer Connection
Available N/A Available
Multi-client N/A Available -
Dial-up Available Available N/A
Cost No extra cost(included in XP)
140$ CGW hardware
ISD-MASP-S03005 Page.12
Solution Marketing Gr., International Business Headquarters Copyright © Yokogawa Electric CorporationApril 3, 2003-Rev2
Remote DesktopSpecification
ISD-MASP-S03005 Page.13
Solution Marketing Gr., International Business Headquarters Copyright © Yokogawa Electric CorporationApril 3, 2003-Rev2
Requirements for Remote Desktop
For Server (Remote PC, connected to V net)– Hardware : Same as HIS– Software : Windows XP Professional
For Client (Local PC, actually used by operators)– Hardware : No special requirement– Software :
Windows95/98/ME/NT/2000/CE/XPRemote Desktop ClientInstall from Windows XP
CD-ROM
ISD-MASP-S03005 Page.14
Solution Marketing Gr., International Business Headquarters Copyright © Yokogawa Electric CorporationApril 3, 2003-Rev2
Restrictions of Remote Desktop
Caused by the specification of Windows XP, there are some restrictions as below.– Only one Client can connect to one server at the same
time.– USB port is not supported. – Display resolution is recommended to be more than
800 x 600.– Yokogawa’s Operator keyboard is not supported.– Option sound board for alarm is not supported.– Standard buzzer of PC for alarm can be used.
Data refresh period is not deterministic.– In case of LAN, you may feel little slow refreshment.– In case of the access with analog modem, screen
refresh may needs about a few seconds.
ISD-MASP-S03005 Page.15
Solution Marketing Gr., International Business Headquarters Copyright © Yokogawa Electric CorporationApril 3, 2003-Rev2
Support Remote Connection
Telephone LineLAN (Ethernet)
ISD-MASP-S03005 Page.16
Solution Marketing Gr., International Business Headquarters Copyright © Yokogawa Electric CorporationApril 3, 2003-Rev2
Installation Software
RemoteLocal
HIS/ENG
Windows 95
Windows 98
Windows Me
Windows CE
Windows 2000
Windows XP
Operating Environment
Remote Desktop SoftwareThis software includes Windows XP media.
Have to install
ISD-MASP-S03005 Page.17
Solution Marketing Gr., International Business Headquarters Copyright © Yokogawa Electric CorporationApril 3, 2003-Rev2
Installation Setting for Local (Server) HIS/ENG
Check
Open My Computer Properties
Click
Add “CENTUM” user
This user can access from remote PC.If user name do not define, remote PC can not login.
ISD-MASP-S03005 Page.18
Solution Marketing Gr., International Business Headquarters Copyright © Yokogawa Electric CorporationApril 3, 2003-Rev2
Operation Procedure
Step1– Connect Local (Server) HIS/ENG from
Remote PC (Client)
Step2– Enter User Name and Password – (This user name is Local HIS/ENG registered
User Name and Password.)
Step3– Local (Server) PC Logout
ISD-MASP-S03005 Page.19
Solution Marketing Gr., International Business Headquarters Copyright © Yokogawa Electric CorporationApril 3, 2003-Rev2
Operation Step1
Remote PCStart
Accessories
Communications
Remote Access Connection
ISD-MASP-S03005 Page.20
Solution Marketing Gr., International Business Headquarters Copyright © Yokogawa Electric CorporationApril 3, 2003-Rev2
Login Setting
Computer NameUser NamePasswordDomain Name
Enter
ISD-MASP-S03005 Page.21
Solution Marketing Gr., International Business Headquarters Copyright © Yokogawa Electric CorporationApril 3, 2003-Rev2
Operation Step2
Remote PC
After connecting Local HIS/ENG,User login window show.
ISD-MASP-S03005 Page.22
Solution Marketing Gr., International Business Headquarters Copyright © Yokogawa Electric CorporationApril 3, 2003-Rev2
Operation Step2
Enter “ User name” and “Password”
Remote PC
ISD-MASP-S03005 Page.23
Solution Marketing Gr., International Business Headquarters Copyright © Yokogawa Electric CorporationApril 3, 2003-Rev2
Operation Step3
Local HIS/ENGAfter Login success,Local HIS/ENG logout automatically.
ISD-MASP-S03005 Page.24
Solution Marketing Gr., International Business Headquarters Copyright © Yokogawa Electric CorporationApril 3, 2003-Rev2
Remote PC Window after connected
ISD-MASP-S03005 Page.25
Solution Marketing Gr., International Business Headquarters Copyright © Yokogawa Electric CorporationApril 3, 2003-Rev2
Other User login
Local Remote
Login
ISD-MASP-S03005 Page.26
Solution Marketing Gr., International Business Headquarters Copyright © Yokogawa Electric CorporationApril 3, 2003-Rev2
Other User login
Local Remote
Login Message Dialog appear
ISD-MASP-S03005 Page.27
Solution Marketing Gr., International Business Headquarters Copyright © Yokogawa Electric CorporationApril 3, 2003-Rev2
- We wish to contribute the success of the customer.
True Partnership