Multi-wire X Pinches on the COBRA Pulsed Power GeneratorT.A. Shelkovenko, S.A. Pikuz,
J.D. Douglass, R.D. McBride, and D.A. Hammer
Laboratory of Plasma Studies, Cornell UniversityIthaca, NY 14853, USA
6th International Conference on Dense Z-pinches Oxford, 2005
![Page 2: T.A. Shelkovenko et al- Multi-wire X Pinches on the COBRA Pulsed Power Generator](https://reader033.vdocuments.site/reader033/viewer/2022052819/5436c45e219acd0f088b45fd/html5/thumbnails/2.jpg)
![Page 3: T.A. Shelkovenko et al- Multi-wire X Pinches on the COBRA Pulsed Power Generator](https://reader033.vdocuments.site/reader033/viewer/2022052819/5436c45e219acd0f088b45fd/html5/thumbnails/3.jpg)
![Page 4: T.A. Shelkovenko et al- Multi-wire X Pinches on the COBRA Pulsed Power Generator](https://reader033.vdocuments.site/reader033/viewer/2022052819/5436c45e219acd0f088b45fd/html5/thumbnails/4.jpg)
![Page 5: T.A. Shelkovenko et al- Multi-wire X Pinches on the COBRA Pulsed Power Generator](https://reader033.vdocuments.site/reader033/viewer/2022052819/5436c45e219acd0f088b45fd/html5/thumbnails/5.jpg)
Top view of COBRA chamber
![Page 6: T.A. Shelkovenko et al- Multi-wire X Pinches on the COBRA Pulsed Power Generator](https://reader033.vdocuments.site/reader033/viewer/2022052819/5436c45e219acd0f088b45fd/html5/thumbnails/6.jpg)
![Page 7: T.A. Shelkovenko et al- Multi-wire X Pinches on the COBRA Pulsed Power Generator](https://reader033.vdocuments.site/reader033/viewer/2022052819/5436c45e219acd0f088b45fd/html5/thumbnails/7.jpg)
![Page 8: T.A. Shelkovenko et al- Multi-wire X Pinches on the COBRA Pulsed Power Generator](https://reader033.vdocuments.site/reader033/viewer/2022052819/5436c45e219acd0f088b45fd/html5/thumbnails/8.jpg)
![Page 9: T.A. Shelkovenko et al- Multi-wire X Pinches on the COBRA Pulsed Power Generator](https://reader033.vdocuments.site/reader033/viewer/2022052819/5436c45e219acd0f088b45fd/html5/thumbnails/9.jpg)
![Page 10: T.A. Shelkovenko et al- Multi-wire X Pinches on the COBRA Pulsed Power Generator](https://reader033.vdocuments.site/reader033/viewer/2022052819/5436c45e219acd0f088b45fd/html5/thumbnails/10.jpg)
![Page 11: T.A. Shelkovenko et al- Multi-wire X Pinches on the COBRA Pulsed Power Generator](https://reader033.vdocuments.site/reader033/viewer/2022052819/5436c45e219acd0f088b45fd/html5/thumbnails/11.jpg)
![Page 12: T.A. Shelkovenko et al- Multi-wire X Pinches on the COBRA Pulsed Power Generator](https://reader033.vdocuments.site/reader033/viewer/2022052819/5436c45e219acd0f088b45fd/html5/thumbnails/12.jpg)
![Page 13: T.A. Shelkovenko et al- Multi-wire X Pinches on the COBRA Pulsed Power Generator](https://reader033.vdocuments.site/reader033/viewer/2022052819/5436c45e219acd0f088b45fd/html5/thumbnails/13.jpg)
![Page 14: T.A. Shelkovenko et al- Multi-wire X Pinches on the COBRA Pulsed Power Generator](https://reader033.vdocuments.site/reader033/viewer/2022052819/5436c45e219acd0f088b45fd/html5/thumbnails/14.jpg)
![Page 15: T.A. Shelkovenko et al- Multi-wire X Pinches on the COBRA Pulsed Power Generator](https://reader033.vdocuments.site/reader033/viewer/2022052819/5436c45e219acd0f088b45fd/html5/thumbnails/15.jpg)
![Page 16: T.A. Shelkovenko et al- Multi-wire X Pinches on the COBRA Pulsed Power Generator](https://reader033.vdocuments.site/reader033/viewer/2022052819/5436c45e219acd0f088b45fd/html5/thumbnails/16.jpg)
![Page 17: T.A. Shelkovenko et al- Multi-wire X Pinches on the COBRA Pulsed Power Generator](https://reader033.vdocuments.site/reader033/viewer/2022052819/5436c45e219acd0f088b45fd/html5/thumbnails/17.jpg)
X pinches with 1 MA current
![Page 18: T.A. Shelkovenko et al- Multi-wire X Pinches on the COBRA Pulsed Power Generator](https://reader033.vdocuments.site/reader033/viewer/2022052819/5436c45e219acd0f088b45fd/html5/thumbnails/18.jpg)
![Page 19: T.A. Shelkovenko et al- Multi-wire X Pinches on the COBRA Pulsed Power Generator](https://reader033.vdocuments.site/reader033/viewer/2022052819/5436c45e219acd0f088b45fd/html5/thumbnails/19.jpg)
![Page 20: T.A. Shelkovenko et al- Multi-wire X Pinches on the COBRA Pulsed Power Generator](https://reader033.vdocuments.site/reader033/viewer/2022052819/5436c45e219acd0f088b45fd/html5/thumbnails/20.jpg)
![Page 21: T.A. Shelkovenko et al- Multi-wire X Pinches on the COBRA Pulsed Power Generator](https://reader033.vdocuments.site/reader033/viewer/2022052819/5436c45e219acd0f088b45fd/html5/thumbnails/21.jpg)
![Page 22: T.A. Shelkovenko et al- Multi-wire X Pinches on the COBRA Pulsed Power Generator](https://reader033.vdocuments.site/reader033/viewer/2022052819/5436c45e219acd0f088b45fd/html5/thumbnails/22.jpg)
![Page 23: T.A. Shelkovenko et al- Multi-wire X Pinches on the COBRA Pulsed Power Generator](https://reader033.vdocuments.site/reader033/viewer/2022052819/5436c45e219acd0f088b45fd/html5/thumbnails/23.jpg)
X pinch timing
![Page 24: T.A. Shelkovenko et al- Multi-wire X Pinches on the COBRA Pulsed Power Generator](https://reader033.vdocuments.site/reader033/viewer/2022052819/5436c45e219acd0f088b45fd/html5/thumbnails/24.jpg)
Shot#
Imax(kA)
Ixp(kA)
X pinch wires Radiated energy,first burst (mJ)Eγ > 1.7 keV
Radiated energy, allbursts (mJ)Eγ > 1.7 keV
185 520 420 6x40 µm Mo 250 ~ 1200
187 640 550 12x25 µm NiCr 150 ~ 500210 678 590 6x25 µm W 200 ~500212 700 650 6x40 µm Mo 300 ~750217 870 750 6x50 µm Invar 450 ~ 1000320 924 600 8x25 µm
manganin100 (Eγ >2.5 keV) ~500 (Eγ >2.5 keV)
326 1012 850 8x50 µm W > 1700 >1700330 ? ? 8x50 µm W ~ 1600 2500
Table 1. Estimated energy yield of central X pinch on COBRA.
South X pinch Eγ > 0.7 keV
North X pinch Eγ > 0.7 keV
Shot # Load current (kA)
Wires (µm) Energy(mJ) Wires (µm) Energy (mJ)200 820 4x12.7 Mo 15 4x17 Mo -204 926 4x12.7 Mo 10 4x17 Mo -207 1008 4x12.7 Mo 120 4x17 Mo 30208 981 4x12. Mo 55 4x12.7 Mo 20222 917 4x12.7 Mo 40 4x12.7 Mo 10
Table 2. Estimated energy yield of X pinches in a return currentcircuit of the diode on COBRA.
![Page 25: T.A. Shelkovenko et al- Multi-wire X Pinches on the COBRA Pulsed Power Generator](https://reader033.vdocuments.site/reader033/viewer/2022052819/5436c45e219acd0f088b45fd/html5/thumbnails/25.jpg)
![Page 26: T.A. Shelkovenko et al- Multi-wire X Pinches on the COBRA Pulsed Power Generator](https://reader033.vdocuments.site/reader033/viewer/2022052819/5436c45e219acd0f088b45fd/html5/thumbnails/26.jpg)
Conclusions
• COBRA pulsed power generator is a promising device for X pinch experiments.
• The experiments show the X pinches can have very high plasma and x-ray burst parameters if proper wire materials and masses were chosen.
• COBRA generator give the possibility of essentially extend of the X pinches plasma and radiation parameters and, because of that, field of application.
![Page 27: T.A. Shelkovenko et al- Multi-wire X Pinches on the COBRA Pulsed Power Generator](https://reader033.vdocuments.site/reader033/viewer/2022052819/5436c45e219acd0f088b45fd/html5/thumbnails/27.jpg)
This research was supported in part by DOE grant DE-FG03-98ER54496, in part by Sandia national Laboratories Contract AO258, and in part by the
Stewardship Sciences Academic Alliances program of the National Nuclear Security Administration under DOE Cooperative agreement DE-FC03-
02NA00057