“structural report” ‘statement of work’ and the terms...
TRANSCRIPT
tnxTower Report - version 6.1.4.1
December 31, 2015 Mr. Jason Rouse John W. Kelly P.E. Engineering, P.C. Crown Castle 1717 S. Boulder, Suite 300 3530 Toringdon Way, Suite 300 Tulsa, OK 74119 Charlotte, NC 28277 (918) 587-4630 (704) 405-6605 [email protected] Subject: Structural Modification Report Carrier Designation: Verizon Wireless Co-Locate Carrier Site Number: 63310 Carrier Site Name: PINEY GROVE Crown Castle Designation: Crown Castle BU Number: 812483 Crown Castle Site Name: LOCKWOOD 478-011 Crown Castle JDE Job Number: 354151 Crown Castle Work Order Number: 1151444 Crown Castle Application Number: 318548 Rev. 0 Engineering Firm Designation: Project Number: 82913.005.01 Site Data: 2345 Old Ocean Hwy, Bolivia, NC, Brunswick County Latitude 34° 2' 35.3'', Longitude -78° 11' 41.2'' 300 Foot - Guyed Tower Dear Mr. Rouse, We are pleased to submit this “Structural Modification Report” to determine the structural integrity of the above mentioned tower. This analysis has been performed in accordance with the Crown Castle Structural ‘Statement of Work’ and the terms of Crown Castle Purchase Order Number 844597, in accordance with application 318548, revision 0. The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we have determined the tower stress level for the structure and foundation, under the following load case, to be: LC4.7: TSA specified load case with proposed modifications Sufficient Capacity Note: See Table 1 and Table 2 for the proposed and existing/reserved loading, respectively. The analysis has been performed in accordance with the TIA-222-G standard and 2012 North Carolina Building Code based upon a wind speed of 135 mph 3-second gust, exposure category C. All modifications and equipment proposed in this report shall be installed in accordance with the attached drawings for the determined available structural capacity to be effective. We appreciate the opportunity of providing our continuing professional services to you and Crown Castle. If you have any questions or need further assistance on this or any other projects please give us a call. Respectfully submitted by: John W. Kelly P.E. Engineering, P.C. C-4171; Exp: 06/30/16 Jing Zhang, EIT John W. Kelly, P.E., S.E. Project Engineer President
Reviewed For Code Compliance
December 31, 2015 300 Ft Guyed Tower Structural Modification Report CCI BU No. 812483 Project Number 82913.005.01, Application 318548, Revision 0 Page 2
tnxTower Report - version 6.1.4.1
TABLE OF CONTENTS
1) INTRODUCTION 2) ANALYSIS CRITERIA Table 1 - Proposed Antenna and Cable Information Table 2 - Existing and Reserved Antenna and Cable Information Table 3 - Design Antenna and Cable Information 3) ANALYSIS PROCEDURE Table 4 - Documents Provided 3.1) Analysis Method 3.2) Assumptions 4) ANALYSIS RESULTS Table 5 - Section Capacity (Summary) Table 6 - Tower Components vs. Capacity 4.1) Recommendations 5) APPENDIX A tnxTower Output 6) APPENDIX B Base Level Drawing 7) APPENDIX C Additional Calculations 8) APPENDIX D Tower Modification Drawings
Reviewed For Code Compliance
December 31, 2015 300 Ft Guyed Tower Structural Modification Report CCI BU No. 812483 Project Number 82913.005.01, Application 318548, Revision 0 Page 3
tnxTower Report - version 6.1.4.1
1) INTRODUCTION This tower is a 300 ft. guyed tower designed by ROHN in January of 1996. The tower was originally designed for a wind speed of 105 mph per TIA/EIA-222-E. 2) ANALYSIS CRITERIA The structural analysis was performed for this tower in accordance with the requirements of TIA-222-G Structural Standards for Steel Antenna Towers and Antenna Supporting Structures using a 3-second gust wind speed of 135 mph with no ice and 60 mph under service loads, exposure category C.
Table 1 - Proposed Antenna and Cable Information
Mounting Level (ft)
Center Line
Elevation (ft)
Number of
Antennas
Antenna Manufacturer
Antenna Model Number of Feed Lines
Feed Line
Size (in) Note
285.0 285.0
3 Andrew HBXX-6516DS-A2M
1 1-5/8 -- 3 CSS X7C-FRO-860-VR0
3 Ericsson RRUS12/RRUS A2
1 Raycap RHSDC-3315-PF-48
Table 2 - Existing and Reserved Antenna and Cable Information
Mounting Level (ft)
Center Line
Elevation (ft)
Number of
Antennas
Antenna Manufacturer
Antenna Model Number of Feed Lines
Feed Line
Size (in) Note
300.0 300.0
3 Andrew SBNHH-1D65C
2 1
3/4 3/8
2
6 Ericsson RRUS 11
3 Kathrein 742 352
1 Raycap DC6-48-60-18-8F
3 Kenwood T1684KT12-4114
-- -- -- 6 1
2-1/4 3/8
1
295.0 295.0
3 Decibel 983H65T2E-M
13 2-1/4 4 4 Decibel DB982G90E-M
3 Kathrein 741 989
1 -- Sector Mount [SM 406-3]
285.0 285.0
3 Antel BXA-70063/8CFx2 -- -- 4
6 Decibel DB948F85E-M
3 Antel BXA-70080-8CF-EDIN-2
12 1-5/8 1 6 Rfs Celwave FD9R6004
1 -- Sector Mount [SM 402-3]
264.0 264.0 9 Decibel DB848H90E-XY
9 1-5/8 3 1 -- Sector Mount [SM 104-3]
245.0 245.0
2 Ems Wireless RV65-18-02DPL2
6 1-5/8 1 4 Scala AP18-1900/063D
1 -- Sector Mount [SM 501-3]
227.0 229.0
6 Allgon LGP 13904
6 1-5/8 1 6 Dapa 58010
227.0 1 -- Sector Mount [SM 502-3]
Reviewed For Code Compliance
December 31, 2015 300 Ft Guyed Tower Structural Modification Report CCI BU No. 812483 Project Number 82913.005.01, Application 318548, Revision 0 Page 4
tnxTower Report - version 6.1.4.1
Notes: 1) Existing Equipment 2) Reserved Equipment 3) Abandoned Equipment; To Be Removed 4) Equipment To Be Removed; Not Considered in This Analysis
Table 3 - Design Antenna and Cable Information
Mounting Level (ft)
Center Line
Elevation (ft)
Number of
Antennas
Antenna Manufacturer
Antenna Model Number of Feed Lines
Feed Line
Size (in)
300 300 3 Generic Leg Mount
12 2-1/4 3 Generic Smart BTS Panel
290 290 2 Generic 8' Dish w/Radome 2 EW90
283 283 3 Generic 15’ Leg Mounting Frame
12 2-1/4 12 Decibel DB874
3) ANALYSIS PROCEDURE
Table 4 - Documents Provided
Document Remarks Reference Source
Online Application Verizon Wireless Co-Locate Rev# 0 318548 CCIsites
Tower Manufacturer Drawing Rohn, Drawing No. D960612 1084787 CCIsites
Tower Modification Drawing SSOE Work Order No:1031386 5630611 CCIsites
Foundation Mapping FDH, Project No. 146I4K1500 84673 CCIsites
Geotech Report FDH, Project No. 146I431600 84679 CCIsites
Antenna Configuration Crown CAD Package Date: 11/05/2015 CCIsites
3.1) Analysis Method
tnxTower (version 6.1.4.1), a commercially available analysis software package, was used to create a three-dimensional model of the tower and calculate member stresses for various loading cases. Selected output from the analysis is included in Appendix A.
3.2) Assumptions
1) Tower and structures were built in accordance with the manufacturer’s specifications. 2) The tower and structures have been maintained in accordance with the manufacturer’s
specification. 3) The configuration of antennas, transmission cables, mounts and other appurtenances are as
specified in Tables 1 and 2 and the referenced drawings. 4) Mount areas and weights are assumed based on photographs provided. 5) This analysis assumes modification design by SSOE Dated 04/01/2015 will be installed
according to the drawings, except wire tension at 280’ has been adjusted to 9% according to SSOE’s construction email.
6) Assumed SSOE’s anchor plate modification is sufficient for all existing wires.
This analysis may be affected if any assumptions are not valid or have been made in error. We should be notified to determine the effect on the structural integrity of the tower.
Reviewed For Code Compliance
December 31, 2015 300 Ft Guyed Tower Structural Modification Report CCI BU No. 812483 Project Number 82913.005.01, Application 318548, Revision 0 Page 5
tnxTower Report - version 6.1.4.1
4) ANALYSIS RESULTS
Table 5 - Section Capacity (Summary) - LC4.7
Section No.
Elevation (ft) Component Type Size Critical Element
P (K) SF*P_allow (K)
% Capacity
Pass / Fail
T1 300 - 296 Leg ROHN 2.5 EH 3 -4.958 83.252 6.0 Pass
T2 296 - 292 Leg ROHN 2.5 EH 15 -13.401 83.252 16.1 Pass
T3 292 - 288 Leg ROHN 2.5 EH 23 -23.583 83.252 28.3 Pass
T4 288 - 284 Leg ROHN 2.5 EH 33 -34.823 83.252 41.8 Pass
T5 284 - 280 Leg ROHN 2.5 EH 42 -52.912 83.252 63.6 Pass
T6 280 - 276 Leg ROHN 3 EH 51 -49.530 131.362 37.7 Pass
T7 276 - 272 Leg ROHN 3 EH 63 -16.741 131.362 12.7 Pass
T8 272 - 268 Leg ROHN 3 EH 74 -99.453 131.362 75.7 Pass
T9 268 - 264 Leg ROHN 3 EH 86 -120.140 131.362 91.5 Pass
T10 264 - 260 Leg ROHN 3 EH 98 -129.206 131.362 98.4 Pass
T11 260 - 240 Leg BU# 812483---3 XS w/ 4.5x0.5
113 -181.514 235.464 77.1 Pass
T12 240 - 220 Leg BU# 812483---3 XS w/ 4.5x0.5
146 -184.994 235.464 78.6 Pass
T13 220 - 200 Leg BU# 812483---3 XS w/ 4.5x0.5
179 -166.874 235.464 70.9 Pass
T14 200 - 180 Leg ROHN 3 EH 212 -99.940 131.362 76.1 Pass
T15 180 - 160 Leg ROHN 3 EH 261 -98.077 131.362 74.7 Pass
T16 160 - 140 Leg ROHN 3 EH 307 -94.391 131.362 71.9 Pass
T17 140 - 120 Leg ROHN 3 EH 357 -128.906 131.362 98.1 Pass
T18 120 - 100 Leg BU# 812483---3 XS w/ 4.5x0.5
405 -202.524 235.464 86.0 Pass
T19 100 - 80 Leg BU# 812483---3 XS w/ 4.5x0.5
438 -204.532 235.464 86.9 Pass
T20 80 - 60 Leg ROHN 3.5 EH 471 -136.594 149.975 91.1 Pass
T21 60 - 40 Leg ROHN 3.5 EH 504 -139.724 161.495 86.5 Pass
T22 40 - 20 Leg ROHN 3.5 EH 552 -140.268 161.495 86.9 Pass
T23 20 - 8 Leg ROHN 3.5 EH 599 -128.727 149.975 85.8 Pass
T24 8 - 0 Leg ROHN 3.5 EH 619 -123.821 148.029 83.6 Pass
T1 300 - 296 Diagonal L2x2x1/4 10 -3.614 18.370 19.7 40.6 (b)
Pass
T2 296 - 292 Diagonal L2x2x1/4 18 -4.426 18.370 24.1 47.3 (b)
Pass
T3 292 - 288 Diagonal L2x2x1/4 27 -4.598 18.370 25.0 51.9 (b)
Pass
T4 288 - 284 Diagonal L2x2x1/4 37 -6.438 18.370 35.0 67.8 (b)
Pass
T5 284 - 280 Diagonal L2 1/2x2 1/2x1/4 46 -9.579 31.973 30.0 93.9 (b)
Pass
T6 280 - 276 Diagonal L2 1/2x2 1/2x1/4 55 17.878 36.654 48.8 83.2 (b)
Pass
T7 276 - 272 Diagonal L2 1/2x2 1/2x1/4 66 -16.725 35.845 46.7 71.7 (b)
Pass
T8 272 - 268 Diagonal L2x2x1/4 78 -11.851 19.267 61.5 Pass
T9 268 - 264 Diagonal L2x2x1/4 91 -8.074 19.267 41.9 57.8 (b)
Pass
T10 264 - 260 Diagonal L2x2x1/4 105 -10.109 19.267 52.5 Pass
T11 260 - 240 Diagonal L2x2x5/16 142 -7.451 22.631 32.9 93.7 (b)
Pass
T12 240 - 220 Diagonal L2x2x5/16 148 -4.916 22.631 21.7 Pass
Reviewed For Code Compliance
December 31, 2015 300 Ft Guyed Tower Structural Modification Report CCI BU No. 812483 Project Number 82913.005.01, Application 318548, Revision 0 Page 6
tnxTower Report - version 6.1.4.1
Section No. Elevation (ft) Component Type Size Critical
Element P (K) SF*P_allow (K)
% Capacity Pass / Fail
61.8 (b)
T13 220 - 200 Diagonal L2x2x5/16 181 -8.411 22.631 37.2 93.4 (b)
Pass
T14 200 - 180 Diagonal L2x2x5/16 214 -13.279 23.566 56.3 91.2 (b)
Pass
T15 180 - 160 Diagonal L2x2x5/16 301 -6.692 23.566 28.4 53.9 (b)
Pass
T16 160 - 140 Diagonal L2x2x5/16 311 -3.442 23.566 14.6 43.3 (b)
Pass
T17 140 - 120 Diagonal L2x2x5/16 358 -7.032 23.566 29.8 88.4 (b)
Pass
T18 120 - 100 Diagonal L2x2x5/16 408 -8.790 22.631 38.8 98.0 (b)
Pass
T19 100 - 80 Diagonal L2x2x5/16 468 -9.016 22.743 39.6 79.5 (b)
Pass
T20 80 - 60 Diagonal L2x2x5/16 501 -6.354 22.774 27.9 79.9 (b)
Pass
T21 60 - 40 Diagonal L1 1/2x1 1/2x3/16 541 -4.175 7.712 54.1 Pass
T22 40 - 20 Diagonal L1 1/2x1 1/2x3/16 555 -3.691 7.712 47.9 Pass
T23 20 - 8 Diagonal L1 1/2x1 1/2x3/16 603 -5.100 8.107 62.9 94.3 (b)
Pass
T24 8 - 0 Horizontal C25.5x2x3/16 626 0.100 176.934 8.2 Pass
T6 280 - 276 Secondary Horizontal
L1 1/2x1 1/2x1/4 59 -0.858 13.491 6.4 13.7 (b)
Pass
T7 276 - 272 Secondary Horizontal
L1 1/2x1 1/2x1/4 72 -0.303 13.491 2.2 4.6 (b)
Pass
T8 272 - 268 Secondary Horizontal
L1 1/2x1 1/2x1/4 82 -1.723 13.491 12.8 27.5 (b)
Pass
T9 268 - 264 Secondary Horizontal
L1 1/2x1 1/2x1/4 95 2.963 17.332 17.1 47.4 (b)
Pass
T10 264 - 260 Secondary Horizontal
L1 1/2x1 1/2x1/4 110 -2.238 13.491 16.6 35.8 (b)
Pass
T14 200 - 180 Secondary Horizontal
L1 1/2x1 1/2x1/4 221 -1.731 13.491 12.8 34.2 (b)
Pass
T15 180 - 160 Secondary Horizontal
L1 1/2x1 1/2x1/4 269 -1.699 13.491 12.6 34.2 (b)
Pass
T16 160 - 140 Secondary Horizontal
L1 1/2x1 1/2x1/4 353 2.188 17.332 12.6 35.0 (b)
Pass
T17 140 - 120 Secondary Horizontal
L1 1/2x1 1/2x1/4 365 -2.233 13.491 16.6 35.7 (b)
Pass
T21 60 - 40 Secondary Horizontal
L1 1/2x1 1/2x1/4 513 -2.420 13.609 17.8 48.6 (b)
Pass
T22 40 - 20 Secondary Horizontal
L1 1/2x1 1/2x1/4 560 -2.430 13.609 17.9 48.9 (b)
Pass
T1 300 - 296 Top Girt L2x2x1/4 4 -1.502 10.808 13.9 15.6 (b)
Pass
T24 8 - 0 Top Girt C32.75x2x3/16 622 25.896 220.978 11.7 Pass
T10 264 - 260 Bottom Girt L4x2x1/4 101 4.162 40.781 10.2 17.9 (b)
Pass
T6 280 - 276 Guy A@280 1 658 57.754 62.700 92.1 Pass
T15 180 - 160 Guy A@180 1 639 64.549 62.700 102.9 Pass2
T19 100 - 80 Guy A@100 1 633 54.903 62.700 87.6 Pass
T6 280 - 276 Guy B@280 1 653 57.748 62.700 92.1 Pass
T15 180 - 160 Guy B@180 1 638 64.580 62.700 103.0 Pass2
T19 100 - 80 Guy B@100 1 632 54.913 62.700 87.6 Pass
T6 280 - 276 Guy C@280 1 640 57.327 62.700 91.4 Pass
T15 180 - 160 Guy C@180 1 634 64.551 62.700 103.0 Pass2
Reviewed For Code Compliance
December 31, 2015 300 Ft Guyed Tower Structural Modification Report CCI BU No. 812483 Project Number 82913.005.01, Application 318548, Revision 0 Page 7
tnxTower Report - version 6.1.4.1
Section No. Elevation (ft) Component Type Size Critical
Element P (K) SF*P_allow (K)
% Capacity Pass / Fail
T19 100 - 80 Guy C@100 1 628 54.903 62.700 87.6 Pass
T6 280 - 276 Top Guy Pull-Off@280
2L2x2x3/8x3/8 644 48.506 70.388 68.9 98.3 (b)
Pass
T15 180 - 160 Top Guy Pull-Off@180
2L3x2x1/4x3/8 636 24.883 63.374 39.3 74.3 (b)
Pass
T19 100 - 80 Top Guy Pull-Off@100
2L3x2x1/4x3/8 630 23.979 63.374 37.8 71.6 (b)
Pass
T8 272 - 268 Bottom Guy Pull-Off@280
2L2x2x3/8x3/8 650 -6.367 54.273 11.7 12.8 (b)
Pass
T6 280 - 276 Torque Arm Top@280
L3 1/2x3 1/2x1/2 660 64.053 100.547 63.7 91.1 (b)
Pass
T6 280 - 276 Torque Arm Bottom@280
ROHN 3 STD 663 -58.958 70.416 83.7 Pass
T1 300 - 296 Leg ROHN 2.5 EH 3 -4.958 83.252 6.0 Pass
Summary
Leg (T10) 98.4 Pass
Diagonal (T18) 98.0 Pass
Horizontal (T24) 8.2 Pass
Secondary Horizontal (T22) 48.9 Pass
Top Girt (T1) 15.6 Pass
Bottom Girt (T10) 17.9 Pass
Guy A (T15) 102.9 Pass2
Guy B (T15) 103.0 Pass2
Guy C (T15) 103.0 Pass2
Top Guy Pull-Off (T6) 98.3 Pass
Bottom Guy Pull-Off (T8) 12.8 Pass
Torque Arm Top (T6) 91.1 Pass
Torque Arm Bottom (T6) 83.7 Pass
Bolt Checks 103.0 Pass2
RATING = 103.0 Pass2
Table 6 - Tower Component Stresses vs. Capacity - LC4.7
Notes Component Elevation (ft) % Capacity Pass / Fail
1,2,3 Base Foundation Structure Base 101.6 Pass
1,3 Base Foundation Soil Interaction Base 95.3 Pass
1,3 Guy Anchor Foundation (Structure) Base 80.0 Pass
1,3 Guy Anchor Foundation (Soil Interaction) Base 54.3 Pass
Structure Rating (max from all components) = 103.0%
Notes: 1) See additional documentation in “Appendix C – Additional Calculations” for calculations supporting the % capacity
consumed. 2) Capacities up to 105% are considered acceptable based on analysis methods used. 3) Base reaction has been increased to account for angle shape top torque arm.
4.1) Recommendations
1) All modifications proposed in this report shall be installed in accordance with the attached drawings (Appendix D) for the determined available structural capacity to be effective.
Reviewed For Code Compliance
APPENDIX A
TNXTOWER OUTPUT
Reviewed For Code Compliance
B+T Group 1717 South Boulder Ave., Suite 300
Tulsa, OK 74119 Phone: (918) 587-4630 FAX: (918) 295-0265
Job: 82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483
Project:
Client: Crown Castle Drawn by: jzhang App'd:
Code: TIA-222-G Date: 12/30/15 Scale: NTS Path:
C:\Users\jzhang\Desktop\Jing's Projects\Projects\11 Nov\82913_812483_Lockwood 478-011_GT_TA\tnx\test\new\2.5\82913_005_01_Lockwood 478-011_NC_test 2.5.eri
Dwg No. E-1
1 EHS LC=239'5/32" IT=12%
R=220'
1 EHS LC=282'3/32" IT=7%
1 EH
S LC
=353'4-5/32" IT=9%
1 EHS LC
=353'4-5/32" IT=9%
300.0 ft
296.0 ft
292.0 ft
288.0 ft
284.0 ft
280.0 ft
276.0 ft
272.0 ft
268.0 ft
264.0 ft
260.0 ft
240.0 ft
220.0 ft
200.0 ft
180.0 ft
160.0 ft
140.0 ft
120.0 ft
100.0 ft
80.0 ft
60.0 ft
40.0 ft
20.0 ft
8.0 ft
0.0 ft
321 K (Axial)3 kip-ft (Torque)
8 K168 K
148 K
224 K
ALL REACTIONS ARE FACTORED
S
ect
ion
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
T11
T12
T13
T14
T15
T16
T17
T18
T19
T20
T21
T22
T23
T24
L
eg
sR
OH
N 2
.5 E
HR
OH
N 3
EH
BU
# 8
12
48
3--
-3 X
S w
/ 4
.5x0
.5R
OH
N 3
EH
BU
# 8
12
48
3--
-3 X
S w
/ 4
.5x0
.5R
OH
N 3
.5 E
H
L
eg
Gra
de
A5
72
-50
D
iag
on
als
L2
x2x1
/4A
L2
x2x1
/4L
2x2
x5/1
6L
1 1
/2x1
1/2
x3/1
6N
.A.
D
iag
on
al G
rad
eA
36
A5
72
-50
A3
6N
.A.
T
op
Gir
tsB
N.A
.C
B
ott
om
Gir
tsN
.A.
DN
.A.
H
ori
zon
tals
N.A
.E
S
ec.
Ho
rizo
nta
lsN
.A.
FN
.A.
L1
1/2
x1 1
/2x1
/4N
.A.
L1
1/2
x1 1
/2x1
/4N
.A.
T
op
Gu
y P
ull-
Off
sN
.A.
GN
.A.
2L
3x2
x1/4
x3/8
N.A
.2
L3
x2x1
/4x3
/8N
.A.
B
ot
Gu
y P
ull-
Off
sN
.A.
GN
.A.
F
ace
Wid
th (
ft)
5.0
41
67
#
Pa
ne
ls @
(ft
)7
5 @
4
W
eig
ht
(K)
0.3
0.2
0.2
0.2
0.3
1.6
0.3
0.4
0.3
0.4
2.1
2.1
2.1
1.6
1.8
1.6
1.6
2.1
2.2
1.6
1.3
1.3
0.7
0.9
27
.3
PLANR=220' R=220'
R=220'
R=220' R=220'
R=220'
R=220' R=220'
R=220'
Lightning Rod 5/8" x 3' on 7' Mount Pipe (E)
300 Flash Beacon Lighting (E) 300 SBNHH-1D65C w/ Mount Pipe (R) 300 SBNHH-1D65C w/ Mount Pipe (R) 300 SBNHH-1D65C w/ Mount Pipe (R) 300 742 352 w/ Mount Pipe (R) 300 742 352 w/ Mount Pipe (R) 300 742 352 w/ Mount Pipe (R) 300 (2) RRUS 11 (R) 300 (2) RRUS 11 (R) 300 (2) RRUS 11 (R) 300 DC6-48-60-18-8F (R) 300 Sector Mount [SM 1303-3] (R) 300 BXA-70080-8CF-EDIN-2 w/ Mount Pipe (E)
285 BXA-70080-8CF-EDIN-2 w/ Mount Pipe (E)
285 BXA-70080-8CF-EDIN-2 w/ Mount Pipe (E)
285 (2) FD9R6004 (E) 285 (2) FD9R6004 (E) 285 (2) FD9R6004 (E) 285 X7C-FRO-860-VR0 (P) 285 X7C-FRO-860-VR0 (P) 285 X7C-FRO-860-VR0 (P) 285 HBXX-6516DS-A2M (P) 285 HBXX-6516DS-A2M (P) 285 HBXX-6516DS-A2M (P) 285 RHSDC-3315-PF-48 (P) 285 RRUS12/RRUS A2 (P) 285 RRUS12/RRUS A2 (P) 285 RRUS12/RRUS A2 (P) 285 6' x 2" Mount Pipe (E) 285 6' x 2" Mount Pipe (E) 285 6' x 2" Mount Pipe (E) 285 Sector Mount [SM 402-3] (E-2 Pipes/Sector)
285 (2) RV65-18-02DPL2 w/ Mount Pipe (E)
245 (2) AP18-1900/063D w/ Mount Pipe (E)
245 (2) AP18-1900/063D w/ Mount Pipe (E)
245 Sector Mount [SM 501-3] (E) 245 (2) 58010 w/ Mount Pipe (E) 227 (2) 58010 w/ Mount Pipe (E) 227 (2) 58010 w/ Mount Pipe (E) 227 (2) LGP 13904 (E) 227 (2) LGP 13904 (E) 227 (2) LGP 13904 (E) 227 6' x 2" Mount Pipe (E) 227 6' x 2" Mount Pipe (E) 227 6' x 2" Mount Pipe (E) 227 Sector Mount [SM 502-3] (E) 227 Side Lighting (E) 151 Side Lighting (E) 151 Side Lighting (E) 151DESIGNED APPURTENANCE LOADINGTYPE TYPEELEVATION ELEVATION
Lightning Rod 5/8" x 3' on 7' Mount Pipe (E)
300
Flash Beacon Lighting (E) 300
SBNHH-1D65C w/ Mount Pipe (R) 300
SBNHH-1D65C w/ Mount Pipe (R) 300
SBNHH-1D65C w/ Mount Pipe (R) 300
742 352 w/ Mount Pipe (R) 300
742 352 w/ Mount Pipe (R) 300
742 352 w/ Mount Pipe (R) 300
(2) RRUS 11 (R) 300
(2) RRUS 11 (R) 300
(2) RRUS 11 (R) 300
DC6-48-60-18-8F (R) 300
Sector Mount [SM 1303-3] (R) 300
BXA-70080-8CF-EDIN-2 w/ Mount Pipe (E)
285
BXA-70080-8CF-EDIN-2 w/ Mount Pipe (E)
285
BXA-70080-8CF-EDIN-2 w/ Mount Pipe (E)
285
(2) FD9R6004 (E) 285
(2) FD9R6004 (E) 285
(2) FD9R6004 (E) 285
X7C-FRO-860-VR0 (P) 285
X7C-FRO-860-VR0 (P) 285
X7C-FRO-860-VR0 (P) 285
HBXX-6516DS-A2M (P) 285
HBXX-6516DS-A2M (P) 285
HBXX-6516DS-A2M (P) 285
RHSDC-3315-PF-48 (P) 285
RRUS12/RRUS A2 (P) 285
RRUS12/RRUS A2 (P) 285
RRUS12/RRUS A2 (P) 285
6' x 2" Mount Pipe (E) 285
6' x 2" Mount Pipe (E) 285
6' x 2" Mount Pipe (E) 285
Sector Mount [SM 402-3] (E-2 Pipes/Sector)
285
(2) RV65-18-02DPL2 w/ Mount Pipe (E)
245
(2) AP18-1900/063D w/ Mount Pipe (E)
245
(2) AP18-1900/063D w/ Mount Pipe (E)
245
Sector Mount [SM 501-3] (E) 245
(2) 58010 w/ Mount Pipe (E) 227
(2) 58010 w/ Mount Pipe (E) 227
(2) 58010 w/ Mount Pipe (E) 227
(2) LGP 13904 (E) 227
(2) LGP 13904 (E) 227
(2) LGP 13904 (E) 227
6' x 2" Mount Pipe (E) 227
6' x 2" Mount Pipe (E) 227
6' x 2" Mount Pipe (E) 227
Sector Mount [SM 502-3] (E) 227
Side Lighting (E) 151
Side Lighting (E) 151
Side Lighting (E) 151
SYMBOL LISTMARK MARKSIZE SIZE
A L2 1/2x2 1/2x1/4
B L2x2x1/4
C C32.75x2x3/16
D L4x2x1/4
E C25.5x2x3/16
F L1 1/2x1 1/2x1/4
G 2L2x2x3/8x3/8
MATERIAL STRENGTHGRADE GRADEFy FyFu Fu
A572-50 50 ksi 65 ksi A36 36 ksi 58 ksi
TOWER DESIGN NOTES1. Tower is located in Brunswick County, North Carolina.2. Tower designed for Exposure C to the TIA-222-G Standard.3. Tower designed for a 135 mph basic wind in accordance with the TIA-222-G Standard.4. Deflections are based upon a 60 mph wind.5. Tower Structure Class II.6. Topographic Category 1 with Crest Height of 0'7. TOWER RATING: 103.0%
Reviewed For Code Compliance
B+T Group 1717 South Boulder Ave., Suite 300
Tulsa, OK 74119 Phone: (918) 587-4630 FAX: (918) 295-0265
Job: 82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483
Project:
Client: Crown Castle Drawn by: jzhang App'd:
Code: TIA-222-G Date: 12/30/15 Scale: NTS Path:
C:\Users\jzhang\Desktop\Jing's Projects\Projects\11 Nov\82913_812483_Lockwood 478-011_GT_TA\tnx\test\new\test 2\82913_005_01_Lockwood 478-011_NC_test 2.eri
Dwg No. E-2
Base Elev=0'
R=220', 240 deg Azimuth R=220', 120 deg Azimuth
R=220', 0 deg Azimuth
15' 15'
411'5/8"
190'6-5/16" 190'6-5/16"
36
0'
15
'1
5'
11
0'
22
0'
Plot PlanTotal Area - 3.40 Acres
Reviewed For Code Compliance
B+T Group 1717 South Boulder Ave., Suite 300
Tulsa, OK 74119 Phone: (918) 587-4630 FAX: (918) 295-0265
Job: 82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483
Project:
Client: Crown Castle Drawn by: jzhang App'd:
Code: TIA-222-G Date: 12/30/15 Scale: NTS Path:
C:\Users\jzhang\Desktop\Jing's Projects\Projects\11 Nov\82913_812483_Lockwood 478-011_GT_TA\tnx\test\new\2.5\82913_005_01_Lockwood 478-011_NC_test 2.5.eri
Dwg No. E-3
<- Minimum -0 Maximum ->
<- Minimum -0 Maximum ->
-500
-500
500
500
TIA-222-G - 135 mph Exposure C
Leg Capacity Leg Compression (K)
300' 300'296' 296'292' 292'288' 288'284' 284'280' 280'276' 276'272' 272'268' 268'264' 264'260' 260'
240' 240'
220' 220'
200' 200'
180' 180'
160' 160'
140' 140'
120' 120'
100' 100'
80' 80'
60' 60'
40' 40'
20' 20'
8' 8'
0' 0'
Ele
vati
on
(ft
)
Reviewed For Code Compliance
B+T Group 1717 South Boulder Ave., Suite 300
Tulsa, OK 74119 Phone: (918) 587-4630 FAX: (918) 295-0265
Job: 82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483
Project:
Client: Crown Castle Drawn by: jzhang App'd:
Code: TIA-222-G Date: 12/30/15 Scale: NTS Path:
C:\Users\jzhang\Desktop\Jing's Projects\Projects\11 Nov\82913_812483_Lockwood 478-011_GT_TA\tnx\test\new\2.5\82913_005_01_Lockwood 478-011_NC_test 2.5.eri
Dwg No. E-4
0
0
50
50
Global Mast Shear (K)300'296'292'288'284'280'276'272'268'264'260'
240'
220'
200'
180'
160'
140'
120'
100'
80'
60'
40'
20'
8'
0'
Ele
vati
on
(ft
)
0
0
500
500
1000
1000
Global Mast Moment (kip-ft)300'296'292'288'284'280'276'272'268'264'260'
240'
220'
200'
180'
160'
140'
120'
100'
80'
60'
40'
20'
8'
0'
TIA-222-G - 135 mph Exposure C Maximum Values
Vx Vz Mx Mz
Reviewed For Code Compliance
B+T Group 1717 South Boulder Ave., Suite 300
Tulsa, OK 74119 Phone: (918) 587-4630 FAX: (918) 295-0265
Job: 82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483
Project:
Client: Crown Castle Drawn by: jzhang App'd:
Code: TIA-222-G Date: 12/30/15 Scale: NTS Path:
C:\Users\jzhang\Desktop\Jing's Projects\Projects\11 Nov\82913_812483_Lockwood 478-011_GT_TA\tnx\test\new\2.5\82913_005_01_Lockwood 478-011_NC_test 2.5.eri
Dwg No. E-5
TIA-222-G - Service - 60 mph Maximum Values
0
0
5
5
Deflection (in)300'296'292'288'284'280'276'272'268'264'260'
240'
220'
200'
180'
160'
140'
120'
100'
80'
60'
40'
20'
8'
0'
Ele
vati
on
(ft
)
0
0
0.05
0.05
0.1
0.1
Tilt (deg)0
0
0.05
0.05
0.1
0.1
Twist (deg)300'296'292'288'284'280'276'272'268'264'260'
240'
220'
200'
180'
160'
140'
120'
100'
80'
60'
40'
20'
8'
0'
Reviewed For Code Compliance
B+T Group 1717 South Boulder Ave., Suite 300
Tulsa, OK 74119 Phone: (918) 587-4630 FAX: (918) 295-0265
Job: 82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483
Project:
Client: Crown Castle Drawn by: jzhang App'd:
Code: TIA-222-G Date: 12/30/15 Scale: NTS Path:
C:\Users\jzhang\Desktop\Jing's Projects\Projects\11 Nov\82913_812483_Lockwood 478-011_GT_TA\tnx\test\new\2.5\82913_005_01_Lockwood 478-011_NC_test 2.5.eri
Dwg No. E-6
300.0 ft296.0 ft292.0 ft288.0 ft284.0 ft280.0 ft276.0 ft272.0 ft268.0 ft264.0 ft260.0 ft
240.0 ft
220.0 ft
200.0 ft
180.0 ft
160.0 ft
140.0 ft
120.0 ft
100.0 ft
80.0 ft
60.0 ft
40.0 ft
20.0 ft
8.0 ft
0.0 ft
321 K (Axial)3 kip-ft (Torque)
8 K
168 K
ELEVATION
148 K41 deg
168 K
5 K
PLAN
224 K
100'
180'
280'
1 EHS, SF = 1.14, Tmax = 54.913 K, Lc = 239'5/32", Lu = 238'8-31/32", Ls = 239'10-3/4"
R=220'
1 EHS, SF = 0.97, Tmax = 64.580 K, Lc = 282'3/32", Lu = 281'9-15/16", Ls = 283'5-1/32"
1 EH
S, S
F = 1.09, Tmax = 57.754 K
, Lc = 353'4-5/32", Lu = 353'3/16", Ls = 354'9-9/16"
Guy Tensions and Tower ReactionsTIA-222-G - 135 mph Exposure C
Maximum Values
Anchor 'C'@220 ft Azimuth 240 deg Elev 0 ft
Plane through centroid of tower
Reviewed For Code Compliance
B+T Group 1717 South Boulder Ave., Suite 300
Tulsa, OK 74119 Phone: (918) 587-4630 FAX: (918) 295-0265
Job: 82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483
Project:
Client: Crown Castle Drawn by: jzhang App'd:
Code: TIA-222-G Date: 12/30/15 Scale: NTS Path:
C:\Users\jzhang\Desktop\Jing's Projects\Projects\11 Nov\82913_812483_Lockwood 478-011_GT_TA\tnx\test\new\2.5\82913_005_01_Lockwood 478-011_NC_test 2.5.eri
Dwg No. E-7
Feed Line Distribution Chart8' - 300'
Round Flat App In Face App Out Face Truss Leg
Face A296'
292'
288'
284'
280'
276'
272'
268'
264'
260'
240'
220'
200'
180'
160'
140'
120'
100'
80'
60'
40'
20'
8'
300'
Ele
vati
on
(ft
)
(6)
LD
F7
-50
A(1
-5/8
") (
E)
(12
) L
DF
7-5
0A
(1-5
/8")
(E
)
(6)
LD
F7
-50
A(1
-5/8
") (
E)
(2)
LD
F4
-50
A(1
/2")
(E
-Sid
e L
igh
ts)
LD
F4
-50
A(1
/2")
(E
-Sid
e L
igh
ts)
RO
HN
Wa
veg
uid
e B
rack
ets
(E
)
Face B
285'
227'227'
245'
151'151'
285'
(6)
LD
F1
2-5
0A
(2-1
/4")
(E
)
(2)
WR
-VG
86
ST
-BR
D(
3/4
) (R
)
(2)
FB
-L9
8B
-03
4-X
XX
XX
X(
3/8
) (R
(1)+
E(1
))
Sa
fety
Lin
e 3
/8 (
E)
RO
HN
Wa
veg
uid
e B
rack
ets
(E
)
Face C296'
292'
288'
284'
280'
276'
272'
268'
264'
260'
240'
220'
200'
180'
160'
140'
120'
100'
80'
60'
40'
20'
8'
300'
285'
227'227'
245'
151'151'
285'
(7)
LD
F7
-50
A(1
-5/8
") (
6E
+1
P)
RO
HN
Wa
veg
uid
e B
rack
ets
(E
)
Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
1 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Tower Input Data
The main tower is a 3x guyed tower with an overall height of 300' above the ground line.
The base of the tower is set at an elevation of 0' above the ground line.
The face width of the tower is 5'1/2'' at the top and tapered at the base.
This tower is designed using the TIA-222-G standard.
The following design criteria apply:
Tower is located in Brunswick County, North Carolina.
Basic wind speed of 135 mph.
Structure Class II.
Exposure Category C.
Topographic Category 1.
Crest Height 0'.
Deflections calculated using a wind speed of 60 mph.
TOWER RATING: 102.9%.
Pressures are calculated at each section.
Safety factor used in guy design is 1.
Stress ratio used in tower member design is 1.
Local bending stresses due to climbing loads, feed line supports, and appurtenance mounts are not considered.
Options
Consider Moments - Legs Distribute Leg Loads As Uniform Treat Feedline Bundles As Cylinder
Consider Moments - Horizontals Assume Legs Pinned Use ASCE 10 X-Brace Ly Rules
Consider Moments - Diagonals √ Assume Rigid Index Plate √ Calculate Redundant Bracing Forces
Use Moment Magnification √ Use Clear Spans For Wind Area Ignore Redundant Members in FEA
√ Use Code Stress Ratios √ Use Clear Spans For KL/r √ SR Leg Bolts Resist Compression √ Use Code Safety Factors - Guys √ Retension Guys To Initial Tension All Leg Panels Have Same Allowable
Escalate Ice √ Bypass Mast Stability Checks Offset Girt At Foundation Always Use Max Kz √ Use Azimuth Dish Coefficients √ Consider Feedline Torque
Use Special Wind Profile √ Project Wind Area of Appurt. √ Include Angle Block Shear Check
√ Include Bolts In Member Capacity √ Autocalc Torque Arm Areas Poles √ Leg Bolts Are At Top Of Section SR Members Have Cut Ends Include Shear-Torsion Interaction
√ Secondary Horizontal Braces Leg √ Sort Capacity Reports By Component Always Use Sub-Critical Flow Use Diamond Inner Bracing (4 Sided) Triangulate Diamond Inner Bracing Use Top Mounted Sockets
Add IBC .6D+W Combination Use TIA-222-G Tension Splice Capacity
Exemption
Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
2 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Leg B
Guy B
Leg C
Guy C
Leg A
Guy A
Face
A Face B
Face C
Corner & Starmount Guyed Tower
Wind 0
Wind 90
Wind 180
Z
X
Leg B
Guy B
Leg C
Guy C
Leg A
Guy
A
Face
A Face B
Face C
Face Guyed
Wind 0
Wind 90
Wind 180
Z
X
Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
3 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Tower Section Geometry
Tower
Section
Tower
Elevation
ft
Assembly
Database
Description Section
Width
ft
Number
of Sections
Section
Length
ft
T1 300'-296' 5'1/2'' 1 4' T2 296'-292' 5'1/2'' 1 4'
T3 292'-288' 5'1/2'' 1 4' T4 288'-284' 5'1/2'' 1 4'
T5 284'-280' 5'1/2'' 1 4'
T6 280'-276' 5'1/2'' 1 4' T7 276'-272' 5'1/2'' 1 4'
T8 272'-268' 5'1/2'' 1 4' T9 268'-264' 5'1/2'' 1 4'
T10 264'-260' 5'1/2'' 1 4'
T11 260'-240' 5'1/2'' 1 20' T12 240'-220' 5'1/2'' 1 20'
T13 220'-200' 5'1/2'' 1 20' T14 200'-180' 5'1/2'' 1 20'
T15 180'-160' 5'1/2'' 1 20'
T16 160'-140' 5'1/2'' 1 20' T17 140'-120' 5'1/2'' 1 20'
T18 120'-100' 5'1/2'' 1 20' T19 100'-80' 5'1/2'' 1 20'
T20 80'-60' 5'1/2'' 1 20'
T21 60'-40' 5'1/2'' 1 20' T22 40'-20' 5'1/2'' 1 20'
T23 20'-8' 5'1/2'' 1 12' T24 8'-0' 5'1/2'' 1 8'
Tower Section Geometry (cont’d)
Tower
Section
Tower
Elevation
ft
Diagonal
Spacing
ft
Bracing
Type
Has
K Brace End
Panels
Has
Horizontals
Top Girt
Offset
in
Bottom Girt
Offset
in
T1 300'-296' 4' X Brace No No 0.000 0.000
T2 296'-292' 4' X Brace No No 0.000 0.000 T3 292'-288' 4' X Brace No No 0.000 0.000
T4 288'-284' 4' X Brace No No 0.000 0.000 T5 284'-280' 4' X Brace No No 0.000 0.000
T6 280'-276' 4' X Brace No Yes 0.000 0.000
T7 276'-272' 4' X Brace No Yes 0.000 0.000 T8 272'-268' 4' X Brace No Yes 0.000 0.000
T9 268'-264' 4' X Brace No Yes 0.000 0.000 T10 264'-260' 4' X Brace No Yes 0.000 0.000
T11 260'-240' 4' X Brace No No 0.000 0.000
T12 240'-220' 4' X Brace No No 0.000 0.000 T13 220'-200' 4' X Brace No No 0.000 0.000
T14 200'-180' 4' X Brace No Yes 0.000 0.000 T15 180'-160' 4' X Brace No Yes 0.000 0.000
T16 160'-140' 4' X Brace No Yes 0.000 0.000
T17 140'-120' 4' X Brace No Yes 0.000 0.000 T18 120'-100' 4' X Brace No No 0.000 0.000
T19 100'-80' 4' X Brace No No 0.000 0.000 T20 80'-60' 4' X Brace No No 0.000 0.000
T21 60'-40' 4' X Brace No Yes 0.000 0.000
T22 40'-20' 4' X Brace No Yes 0.000 0.000 T23 20'-8' 4' X Brace No No 0.000 0.000
T24 8'-0' 4' X Brace No Yes 0.000 0.000
Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
4 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Tower Section Geometry (cont’d)
Tower
Elevation ft
Leg
Type
Leg
Size
Leg
Grade
Diagonal
Type
Diagonal
Size
Diagonal
Grade
T1 300'-296' Pipe ROHN 2.5 EH A572-50
(50 ksi)
Single Angle L2x2x1/4 A36
(36 ksi) T2 296'-292' Pipe ROHN 2.5 EH A572-50
(50 ksi)
Single Angle L2x2x1/4 A36
(36 ksi) T3 292'-288' Pipe ROHN 2.5 EH A572-50
(50 ksi)
Single Angle L2x2x1/4 A36
(36 ksi)
T4 288'-284' Pipe ROHN 2.5 EH A572-50 (50 ksi)
Single Angle L2x2x1/4 A36 (36 ksi)
T5 284'-280' Pipe ROHN 2.5 EH A572-50 (50 ksi)
Equal Angle L2 1/2x2 1/2x1/4 A572-50 (50 ksi)
T6 280'-276' Pipe ROHN 3 EH A572-50
(50 ksi)
Equal Angle L2 1/2x2 1/2x1/4 A572-50
(50 ksi) T7 276'-272' Pipe ROHN 3 EH A572-50
(50 ksi)
Equal Angle L2 1/2x2 1/2x1/4 A572-50
(50 ksi) T8 272'-268' Pipe ROHN 3 EH A572-50
(50 ksi)
Single Angle L2x2x1/4 A36
(36 ksi)
T9 268'-264' Pipe ROHN 3 EH A572-50 (50 ksi)
Single Angle L2x2x1/4 A36 (36 ksi)
T10 264'-260' Pipe ROHN 3 EH A572-50 (50 ksi)
Single Angle L2x2x1/4 A36 (36 ksi)
T11 260'-240' Pipe BU# 812483---3 XS w/
4.5x0.5
A572-50
(50 ksi)
Single Angle L2x2x5/16 A36
(36 ksi) T12 240'-220' Pipe BU# 812483---3 XS w/
4.5x0.5
A572-50
(50 ksi)
Single Angle L2x2x5/16 A36
(36 ksi) T13 220'-200' Pipe BU# 812483---3 XS w/
4.5x0.5
A572-50
(50 ksi)
Single Angle L2x2x5/16 A36
(36 ksi)
T14 200'-180' Pipe ROHN 3 EH A572-50 (50 ksi)
Single Angle L2x2x5/16 A36 (36 ksi)
T15 180'-160' Pipe ROHN 3 EH A572-50
(50 ksi)
Single Angle L2x2x5/16 A36
(36 ksi) T16 160'-140' Pipe ROHN 3 EH A572-50
(50 ksi)
Single Angle L2x2x5/16 A36
(36 ksi) T17 140'-120' Pipe ROHN 3 EH A572-50
(50 ksi)
Single Angle L2x2x5/16 A36
(36 ksi)
T18 120'-100' Pipe BU# 812483---3 XS w/ 4.5x0.5
A572-50 (50 ksi)
Single Angle L2x2x5/16 A36 (36 ksi)
T19 100'-80' Pipe BU# 812483---3 XS w/ 4.5x0.5
A572-50 (50 ksi)
Single Angle L2x2x5/16 A36 (36 ksi)
T20 80'-60' Pipe ROHN 3.5 EH A572-50
(50 ksi)
Equal Angle L2x2x5/16 A36
(36 ksi) T21 60'-40' Pipe ROHN 3.5 EH A572-50
(50 ksi)
Single Angle L1 1/2x1 1/2x3/16 A36
(36 ksi) T22 40'-20' Pipe ROHN 3.5 EH A572-50
(50 ksi)
Single Angle L1 1/2x1 1/2x3/16 A36
(36 ksi)
T23 20'-8' Pipe ROHN 3.5 EH A572-50 (50 ksi)
Equal Angle L1 1/2x1 1/2x3/16 A36 (36 ksi)
T24 8'-0' Pipe ROHN 3.5 EH A572-50 (50 ksi)
Equal Angle A36 (36 ksi)
Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
5 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Tower Section Geometry (cont’d)
Tower
Elevation ft
Top Girt
Type
Top Girt
Size
Top Girt
Grade
Bottom Girt
Type
Bottom Girt
Size
Bottom Girt
Grade
T1 300'-296' Single Angle L2x2x1/4 A36
(36 ksi)
Single Angle A36
(36 ksi) T10 264'-260' Single Angle A36
(36 ksi)
Single Angle L4x2x1/4 A36
(36 ksi) T24 8'-0' Channel C32.75x2x3/16 A36
(36 ksi)
Channel C3x4.1 A36
(36 ksi)
Tower Section Geometry (cont’d)
Tower Elevation
ft
No. of
Mid Girts
Mid Girt Type
Mid Girt Size
Mid Girt Grade
Horizontal Type
Horizontal Size
Horizontal Grade
T24 8'-0' None Flat Bar A36
(36 ksi)
Channel C25.5x2x3/16 A36
(36 ksi)
Tower Section Geometry (cont’d)
Tower Elevation
ft
Secondary Horizontal Type
Secondary Horizontal Size
Secondary Horizontal
Grade
Inner Bracing Type
Inner Bracing Size
Inner Bracing Grade
T6 280'-276' Equal Angle L1 1/2x1 1/2x1/4 A36
(36 ksi)
Solid Round A36
(36 ksi) T7 276'-272' Equal Angle L1 1/2x1 1/2x1/4 A36
(36 ksi)
Solid Round A36
(36 ksi)
T8 272'-268' Equal Angle L1 1/2x1 1/2x1/4 A36 (36 ksi)
Solid Round A36 (36 ksi)
T9 268'-264' Equal Angle L1 1/2x1 1/2x1/4 A36 (36 ksi)
Solid Round A36 (36 ksi)
T10 264'-260' Equal Angle L1 1/2x1 1/2x1/4 A36
(36 ksi)
Solid Round A36
(36 ksi) T14 200'-180' Equal Angle L1 1/2x1 1/2x1/4 A36
(36 ksi)
Solid Round A36
(36 ksi) T15 180'-160' Equal Angle L1 1/2x1 1/2x1/4 A36
(36 ksi)
Solid Round A36
(36 ksi)
T16 160'-140' Equal Angle L1 1/2x1 1/2x1/4 A36 (36 ksi)
Solid Round A36 (36 ksi)
T17 140'-120' Equal Angle L1 1/2x1 1/2x1/4 A36 (36 ksi)
Solid Round A36 (36 ksi)
T21 60'-40' Equal Angle L1 1/2x1 1/2x1/4 A36
(36 ksi)
Solid Round A36
(36 ksi) T22 40'-20' Equal Angle L1 1/2x1 1/2x1/4 A36
(36 ksi)
Solid Round A36
(36 ksi)
Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
6 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Tower Section Geometry (cont’d)
Tower
Elevation
ft
Gusset
Area (per face)
ft2
Gusset
Thickness
in
Gusset Grade Adjust. Factor
Af
Adjust.
Factor Ar
Weight Mult.
Double Angle
Stitch Bolt Spacing
Diagonals in
Double Angle
Stitch Bolt Spacing
Horizontals in
T1 300'-296' 0.000 0.250 A36
(36 ksi)
1.03 1 1.05 Mid-Pt Mid-Pt
T2 296'-292' 0.000 0.250 A36
(36 ksi)
1.03 1 1.05 Mid-Pt Mid-Pt
T3 292'-288' 0.000 0.250 A36 (36 ksi)
1.03 1 1.05 Mid-Pt Mid-Pt
T4 288'-284' 0.000 0.250 A36 (36 ksi)
1.03 1 1.05 Mid-Pt Mid-Pt
T5 284'-280' 0.000 0.250 A36
(36 ksi)
1.03 1 1.05 Mid-Pt Mid-Pt
T6 280'-276' 0.000 0.375 A36
(36 ksi)
1.03 1.02 1.05 Mid-Pt Mid-Pt
T7 276'-272' 0.000 0.375 A36
(36 ksi)
1.03 1 1.05 Mid-Pt Mid-Pt
T8 272'-268' 0.000 0.375 A36 (36 ksi)
1.03 1 1.05 Mid-Pt Mid-Pt
T9 268'-264' 0.000 0.375 A36 (36 ksi)
1.03 1 1.05 Mid-Pt Mid-Pt
T10 264'-260' 0.000 0.375 A36
(36 ksi)
1.03 1 1.05 Mid-Pt Mid-Pt
T11 260'-240' 0.000 0.250 A36
(36 ksi)
1.03 1 1.05 Mid-Pt Mid-Pt
T12 240'-220' 0.000 0.250 A36
(36 ksi)
1.03 1 1.05 Mid-Pt Mid-Pt
T13 220'-200' 0.000 0.375 A36 (36 ksi)
1.03 1 1.05 Mid-Pt Mid-Pt
T14 200'-180' 0.000 0.375 A36
(36 ksi)
1.03 1 1.05 Mid-Pt Mid-Pt
T15 180'-160' 0.000 0.250 A36
(36 ksi)
1.03 1 1.05 Mid-Pt Mid-Pt
T16 160'-140' 0.000 0.250 A36
(36 ksi)
1.03 1 1.05 Mid-Pt Mid-Pt
T17 140'-120' 0.000 0.250 A36 (36 ksi)
1.03 1 1.05 Mid-Pt Mid-Pt
T18 120'-100' 0.000 0.250 A36 (36 ksi)
1.03 1 1.05 Mid-Pt Mid-Pt
T19 100'-80' 0.000 0.250 A36
(36 ksi)
1.03 1 1.05 Mid-Pt Mid-Pt
T20 80'-60' 0.000 0.250 A36
(36 ksi)
1.03 1 1.05 Mid-Pt Mid-Pt
T21 60'-40' 0.000 0.250 A36
(36 ksi)
1.03 1 1.05 Mid-Pt Mid-Pt
T22 40'-20' 0.000 0.250 A36 (36 ksi)
1.03 1 1.05 Mid-Pt Mid-Pt
T23 20'-8' 0.000 0.250 A36 (36 ksi)
1.03 1 1.05 Mid-Pt Mid-Pt
T24 8'-0' 0.000 0.250 A36
(36 ksi)
1 1 1.05 Mid-Pt Mid-Pt
Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
7 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Tower Section Geometry (cont’d)
K Factors1
Tower Elevation
ft
Calc K
Single
Angles
Calc K
Solid
Rounds
Legs X Brace
Diags
X Y
K Brace
Diags
X Y
Single Diags
X Y
Girts
X Y
Horiz.
X Y
Sec. Horiz.
X Y
Inner Brace
X Y
T1 300'-296' Yes No 1 1
1
1
1
1
1
1
1
1
1
1
1
1
1 T2 296'-292' Yes No 1 1
1
1
1
1
1
1
1
1
1
1
1
1
1
T3 292'-288' Yes No 1 1 1
1 1
1 1
1 1
1 1
1 1
1 1
T4 288'-284' Yes No 1 1 1
1 1
1 1
1 1
1 1
1 1
1 1
T5 284'-280' Yes No 1 1
1
1
1
1
1
1
1
1
1
1
1
1
1 T6 280'-276' No No 1 1
1
1
1
1
1
1
1
1
1
0.5
0.5
1
1 T7 276'-272' No No 1 1
1
1
1
1
1
1
1
1
1
0.5
0.5
1
1
T8 272'-268' No No 1 1 1
1 1
1 1
1 1
1 1
0.5 0.5
1 1
T9 268'-264' No No 1 1 1
1 1
1 1
1 1
1 1
0.5 0.5
1 1
T10 264'-260' No No 1 1
1
1
1
1
1
1
1
1
1
0.5
0.5
1
1 T11 260'-240' Yes No 1 1
1
1
1
1
1
1
1
1
1
1
1
1
1
T12 240'-220' Yes No 1 1
1
1
1
1
1
1
1
1
1
1
1
1
1
T13 220'-200' Yes No 1 1 1
1 1
1 1
1 1
1 1
1 1
1 1
T14 200'-180' No No 1 1 1
1 1
1 1
1 1
1 1
0.5 0.5
1 1
T15 180'-160' No No 1 1
1
1
1
1
1
1
1
1
1
0.5
0.5
1
1 T16 160'-140' No No 1 1
1
1
1
1
1
1
1
1
1
0.5
0.5
1
1 T17 140'-120' No No 1 1
1
1
1
1
1
1
1
1
1
0.5
0.5
1
1
T18 120'-100' Yes No 1 1 1
1 1
1 1
1 1
1 1
1 1
1 1
T19 100'-80' Yes No 1 1 1
1 1
1 1
1 1
1 1
1 1
1 1
T20 80'-60' Yes No 1 1
1
1
1
1
1
1
1
1
1
1
1
1
1 T21 60'-40' No No 1 1
1
1
1
1
1
1
1
1
1
0.5
0.5
1
1 T22 40'-20' No No 1 1
1
1
1
1
1
1
1
1
1
0.5
0.5
1
1
T23 20'-8' Yes No 1 1 1
1 1
1 1
1 1
1 1
1 1
1 1
T24 8'-0' Yes No 1 1 1
1 1
1 1
1 1
1 1
1 1
1 1
1Note: K factors are applied to member segment lengths. K-braces without inner supporting members will have the K factor in the out-of-plane direction applied to
the overall length.
Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
8 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Tower Section Geometry (cont’d)
Tower
Elevation ft
Leg Diagonal Top Girt Bottom Girt Mid Girt Long Horizontal Short Horizontal
Net Width
Deduct in
U
Net Width
Deduct in
U
Net Width
Deduct in
U
Net
Width Deduct
in
U
Net
Width Deduct
in
U
Net
Width Deduct
in
U
Net
Width Deduct
in
U
T1 300'-296' 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 T2 296'-292' 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75
T3 292'-288' 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75
T4 288'-284' 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 T5 284'-280' 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75
T6 280'-276' 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 T7 276'-272' 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75
T8 272'-268' 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75
T9 268'-264' 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 T10 264'-260' 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75
T11 260'-240' 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 T12 240'-220' 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75
T13 220'-200' 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75
T14 200'-180' 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 T15 180'-160' 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75
T16 160'-140' 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 T17 140'-120' 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75
T18 120'-100' 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75
T19 100'-80' 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 T20 80'-60' 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75
T21 60'-40' 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75
T22 40'-20' 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75
T23 20'-8' 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75
T24 8'-0' 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75
Tower Section Geometry (cont’d)
Tower Elevation
ft
Leg Connection
Type
Leg Diagonal Top Girt Bottom Girt Mid Girt Long Horizontal Short Horizontal
Bolt Size in
No. Bolt Size in
No. Bolt Size in
No. Bolt Size in
No. Bolt Size in
No. Bolt Size in
No. Bolt Size in
No.
T1 300'-296' Flange 0.875
A325N
0 0.625
A325N
1 0.625
A325N
1 0.000
A325N
0 0.625
A325N
0 0.625
A325N
0 0.500
A325N
0
T2 296'-292' Flange 0.875 A325N
0 0.625 A325N
1 0.625 A325N
0 0.000 A325N
0 0.625 A325N
0 0.625 A325N
0 0.500 A325N
0
T3 292'-288' Flange 0.875 A325N
0 0.625 A325N
1 0.625 A325N
0 0.000 A325N
0 0.625 A325N
0 0.625 A325N
0 0.500 A325N
0
T4 288'-284' Flange 0.875
A325N
0 0.625
A325N
1 0.625
A325N
0 0.000
A325N
0 0.625
A325N
0 0.625
A325N
0 0.500
A325N
0
T5 284'-280' Flange 0.875
A325N
0 0.625
A325X
1 0.625
A325N
0 0.500
A325N
0 0.625
A325N
0 0.625
A325N
0 0.500
A325N
0
T6 280'-276' Flange 0.875
A325N
4 0.625
A325X
2 0.625
A325N
0 0.000
A325N
0 0.625
A325N
0 0.625
A325N
0 0.500
A325N
1
T7 276'-272' Flange 0.875 A325N
0 0.625 A325X
2 0.625 A325N
0 0.000 A325N
0 0.625 A325N
0 0.625 A325N
0 0.500 A325N
1
T8 272'-268' Flange 0.875 A325N
0 0.625 A325N
2 0.625 A325N
0 0.000 A325N
0 0.625 A325N
0 0.625 A325N
0 0.500 A325N
1 Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
9 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Tower Elevation
ft
Leg Connection
Type
Leg Diagonal Top Girt Bottom Girt Mid Girt Long Horizontal Short Horizontal
Bolt Size in
No. Bolt Size in
No. Bolt Size in
No. Bolt Size in
No. Bolt Size in
No. Bolt Size in
No. Bolt Size in
No.
T9 268'-264' Flange 0.875
A325N
0 0.625
A325N
2 0.625
A325N
0 0.000
A325N
0 0.625
A325N
0 0.625
A325N
0 0.500
A325N
1
T10 264'-260' Flange 0.875
A325N
0 0.625
A325N
2 0.625
A325N
0 0.625
A325N
2 0.625
A325N
0 0.625
A325N
0 0.500
A325N
1
T11 260'-240' Flange 0.875
A325N
4 0.500
A325N
1 0.625
A325N
0 0.500
A325N
0 0.625
A325N
0 0.625
A325N
0 0.500
A325N
0
T12 240'-220' Flange 0.875
A325N
4 0.500
A325N
1 0.625
A325N
0 0.500
A325N
0 0.625
A325N
0 0.625
A325N
0 0.500
A325N
0
T13 220'-200' Flange 0.875 A325N
4 0.500 A325X
1 0.625 A325N
0 0.500 A325N
0 0.625 A325N
0 0.625 A325N
0 0.500 A325N
0
T14 200'-180' Flange 0.875
A325N
4 0.625
A325X
1 0.625
A325N
0 0.500
A325N
0 0.625
A325N
0 0.625
A325N
0 0.500
A325N
1
T15 180'-160' Flange 0.875
A325N
4 0.625
A325N
1 0.625
A325N
0 0.500
A325N
0 0.625
A325N
0 0.625
A325N
0 0.500
A325N
1
T16 160'-140' Flange 0.875 A325N
4 0.500 A325N
1 0.625 A325N
0 0.000 A325N
0 0.625 A325N
0 0.625 A325N
0 0.500 A325N
1
T17 140'-120' Flange 0.875 A325N
4 0.500 A325N
1 0.625 A325N
0 0.000 A325N
0 0.625 A325N
0 0.625 A325N
0 0.500 A325N
1
T18 120'-100' Flange 0.875
A325N
4 0.500
A325X
1 0.625
A325N
0 0.000
A325N
0 0.625
A325N
0 0.625
A325N
0 0.500
A325N
0
T19 100'-80' Flange 0.875
A325N
4 0.625
A325N
1 0.625
A325N
0 0.000
A325N
0 0.625
A325N
0 0.625
A325N
0 0.500
A325N
0
T20 80'-60' Flange 0.875
A325N
4 0.500
A325N
1 0.625
A325N
0 0.000
A325N
0 0.625
A325N
0 0.625
A325N
0 0.500
A325N
0
T21 60'-40' Flange 0.875 A325N
4 0.500 A325N
1 0.625 A325N
0 0.000 A325N
0 0.625 A325N
0 0.625 A325N
0 0.500 A325N
1
T22 40'-20' Flange 0.875 A325N
4 0.500 A325N
1 0.625 A325N
0 0.000 A325N
0 0.625 A325N
0 0.625 A325N
0 0.500 A325N
1
T23 20'-8' Flange 0.875
A325N
4 0.500
A325N
1 0.625
A325N
0 0.500
A325N
0 0.625
A325N
0 0.625
A325N
0 0.500
A325N
0
T24 8'-0' Flange 0.875
A325N
4 0.625
A325N
0 0.625
A325N
0 0.500
A325N
0 0.625
A325N
0 0.625
A325N
0 0.500
A325N
0
Guy Data
Guy
Elevation
ft
Guy
Grade
Guy
Size
Initial
Tension
K
%
Guy
Modulus
ksi
Guy
Weight
plf
Lu
ft
Anchor
Radius
ft
Anchor
Azimuth Adj.
°
Anchor
Elevation
ft
End
Fitting Efficiency
%
100 EHS A B
C
1 1
1
12.540 12.540
12.540
12% 12%
12%
19000.000 19000.000
19000.000
2.100 2.100
2.100
238'9-5/32'' 238'9-5/32''
238'9-5/32''
220' 220'
220'
0.000 0.000
0.000
0' 0'
0'
100% 100%
100% 180 EHS A
B
C
1
1
1
7.315
7.315
7.315
7%
7%
7%
19000.000
19000.000
19000.000
2.100
2.100
2.100
281'10-3/8''
281'10-3/8''
281'10-3/8''
220'
220'
220'
0.000
0.000
0.000
0'
0'
0'
100%
100%
100% 280 EHS A
B C
1
1 1
9.405
9.405 9.405
9%
9% 9%
19000.000
19000.000 19000.000
2.100
2.100 2.100
353'15/16''
353'15/16'' 353'15/16''
220'
220' 220'
0.000
0.000 0.000
0'
0' 0'
100%
100% 100%
Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
10 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Guy Data(cont’d)
Guy
Elevation ft
Mount
Type
Torque-Arm
Spread
ft
Torque-Arm
Leg Angle
°
Torque-Arm
Style
Torque-Arm
Grade
Torque-Arm
Type
Torque-Arm Size
100 Corner 180 Corner
280 Torque Arm 16' 30.000 Bat Ear A572-50 (50 ksi)
Equal Angle Pipe
L3 1/2x3 1/2x1/2 ROHN 3 STD
Guy Data (cont’d)
Guy
Elevation ft
Diagonal
Grade
Diagonal
Type
Upper Diagonal
Size
Lower Diagonal
Size
Is
Strap.
Pull-Off
Grade
Pull-Off Type Pull-Off Size
100' A36
(36 ksi)
Solid Round No A36
(36 ksi)
Double Angle 2L3x2x1/4x3/8
180' A36
(36 ksi)
Solid Round No A36
(36 ksi)
Double Angle 2L3x2x1/4x3/8
280' A36 (36 ksi)
Solid Round No A36 (36 ksi)
Double Angle 2L2x2x3/8x3/8
Guy Data (cont’d)
Guy Elevation
ft
Cable Weight
A
K
Cable Weight
B
K
Cable Weight
C
K
Cable Weight
D
K
Tower Intercept
A
ft
Tower Intercept
B
ft
Tower Intercept
C
ft
Tower Intercept
D
ft
100 0.501 0.501 0.501 4'8-7/8''
3.8 sec/pulse
4'8-7/8''
3.8 sec/pulse
4'8-7/8''
3.8 sec/pulse
180 0.592 0.592 0.592 11'1-17/32'' 5.8 sec/pulse
11'1-17/32'' 5.8 sec/pulse
11'1-17/32'' 5.8 sec/pulse
280 0.741 0.741 0.741 13'6-1/8'' 6.3 sec/pulse
13'6-1/8'' 6.3 sec/pulse
13'6-1/8'' 6.3 sec/pulse
Guy Data (cont’d)
Torque Arm Pull Off Diagonal
Guy Elevation
ft
Calc K
Single
Angles
Calc K
Solid
Rounds
Kx Ky Kx Ky Kx Ky
100 No No 1 1 1 1
180 No No 1 1 1 1
280 No No 0.6 0.6 1 1 1 1
Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
11 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Guy Data (cont’d)
Torque-Arm Pull Off Diagonal
Guy Elevation
ft
Bolt Size in
Number Net Width Deduct
in
U
Bolt Size in
Number Net Width Deduct
in
U
Bolt Size in
Number Net Width Deduct
in
U
100 0.000
A325N
0 0.000 1 0.750
A325N
2 0.000 0.75 0.625
A325N
0 0.000 0.75
180 0.000
A325N
0 0.000 1 0.750
A325N
2 0.000 0.75 0.625
A325N
0 0.000 0.75
280 0.875
A490X
2 0.000 1 0.625
A325N
2 0.000 0.75 0.625
A325N
0 0.000 0.75
Guy Pressures
Guy Elevation
ft
Guy Location
z
ft
qz
ksf
qz Ice
ksf
Ice Thickness
in
100 A B
C
50' 50'
50'
0.043 0.043
0.043
180 A
B
C
90'
90'
90'
0.049
0.049
0.049
280 A
B C
140'
140' 140'
0.054
0.054 0.054
Feed Line/Linear Appurtenances - Entered As Round Or Flat
Description Face
or Leg
Allow
Shield
Component
Type
Placement
ft
Face
Offset in
Lateral
Offset (Frac FW)
# #
Per Row
Clear
Spacing in
Width or
Diameter in
Perimeter
in
Weight
klf
* Face A *
LDF7-50A(1-5/8'') (E)
A No Ar (CaAa) 285' - 0' 0.000 -0.2 6 3 0.500 1.980 0.001
* LDF7-50A(1-5/8'')
(E)
A No Ar (CaAa) 227' - 0' -0.250 0.25 12 6 0.500
0.750
1.980 0.001
LDF7-50A(1-5/8'') (E)
A No Ar (CaAa) 245' - 227' 0.000 0.25 6 6 0.500 0.750
1.980 0.001
* LDF4-50A(1/2'')
(E-Side Lights)
A No Ar (CaAa) 151' - 0' 0.000 0.49 2 2 0.630 0.630 0.000
LDF4-50A(1/2'') (E-Side Lights)
A No Ar (CaAa) 300' - 151' 0.000 0.49 1 1 0.630 0.630 0.000
* Face B * LDF12-50A(2-1/4'')
(E)
B No Ar (CaAa) 300' - 0' 0.000 0 6 6 0.500
0.750
2.350 0.001
WR-VG86ST-BRD( 3/4)
(R)
B No Ar (CaAa) 300' - 0' 0.000 0.18 2 1 0.500 0.774 0.001
FB-L98B-034-XXXXX
X( 3/8)
(R(1)+E(1))
B No Ar (CaAa) 300' - 0' 0.000 0.16 2 1 0.394 0.394 0.000 Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
12 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Description Face or
Leg
Allow Shield
Component Type
Placement
ft
Face Offset
in
Lateral Offset
(Frac FW)
# # Per
Row
Clear Spacing
in
Width or Diameter
in
Perimeter
in
Weight
klf
* Face C * LDF7-50A(1-5/8'')
(6E+1P)
C No Ar (CaAa) 285' - 0' 0.000 -0.35 7 4 0.850
0.750
1.980 0.001
****
Safety Line 3/8
(E)
B No Ar (CaAa) 300' - 0' 0.000 0.5 1 1 0.375 0.375 0.000
***
ROHN Waveguide Brackets
(E)
A No Af (CaAa) 300' - 0' 0.000 0 1 1 1.750 1.750 0.001
ROHN Waveguide Brackets
(E)
B No Af (CaAa) 300' - 0' 0.000 0 1 1 1.750 1.750 0.001
ROHN Waveguide
Brackets
(E)
C No Af (CaAa) 300' - 0' 0.000 0 1 1 1.750 1.750 0.001
*$$$*
Feed Line/Linear Appurtenances Section Areas
Tower Section
Tower Elevation
ft
Face AR
ft2
AF
ft2
CAAA
In Face
ft2
CAAA
Out Face
ft2
Weight
K
T1 300'-296' A B
C
0.000 0.000
0.000
0.000 0.000
0.000
1.419 7.660
1.167
0.000 0.000
0.000
0.006 0.040
0.005
T2 296'-292' A B
C
0.000 0.000
0.000
0.000 0.000
0.000
1.419 7.668
1.167
0.000 0.000
0.000
0.006 0.040
0.005 T3 292'-288' A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
1.419
7.676
1.167
0.000
0.000
0.000
0.006
0.040
0.005 T4 288'-284' A
B C
0.000
0.000 0.000
0.000
0.000 0.000
2.607
7.684 2.553
0.000
0.000 0.000
0.011
0.040 0.011
T5 284'-280' A
B C
0.000
0.000 0.000
0.000
0.000 0.000
6.171
7.692 6.711
0.000
0.000 0.000
0.025
0.040 0.028
T6 280'-276' A B
C
0.000 0.000
0.000
0.000 0.000
0.000
6.171 7.700
6.711
0.000 0.000
0.000
0.025 0.040
0.028
T7 276'-272' A B
C
0.000 0.000
0.000
0.000 0.000
0.000
6.171 7.708
6.711
0.000 0.000
0.000
0.025 0.040
0.028
T8 272'-268' A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
6.171
7.717
6.711
0.000
0.000
0.000
0.025
0.040
0.028 T9 268'-264' A
B C
0.000
0.000 0.000
0.000
0.000 0.000
6.171
7.725 6.711
0.000
0.000 0.000
0.025
0.040 0.028
T10 264'-260' A
B C
0.000
0.000 0.000
0.000
0.000 0.000
6.171
7.734 6.711
0.000
0.000 0.000
0.025
0.040 0.028
T11 260'-240' A B
C
0.000 0.000
0.000
0.000 0.000
0.000
36.793 38.805
33.553
0.000 0.000
0.000
0.151 0.202
0.140
T12 240'-220' A B
0.000 0.000
0.000 0.000
62.929 39.048
0.000 0.000
0.260 0.202
Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
13 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Tower Section
Tower Elevation
ft
Face AR
ft2
AF
ft2
CAAA
In Face
ft2
CAAA
Out Face
ft2
Weight
K
C 0.000 0.000 33.553 0.000 0.140 T13 220'-200' A
B C
0.000
0.000 0.000
0.000
0.000 0.000
78.373
39.316 33.553
0.000
0.000 0.000
0.324
0.202 0.140
T14 200'-180' A
B C
0.000
0.000 0.000
0.000
0.000 0.000
78.373
39.454 33.553
0.000
0.000 0.000
0.324
0.202 0.140
T15 180'-160' A B
C
0.000 0.000
0.000
0.000 0.000
0.000
78.373 39.454
33.553
0.000 0.000
0.000
0.324 0.202
0.140
T16 160'-140' A B
C
0.000 0.000
0.000
0.000 0.000
0.000
79.066 39.454
33.553
0.000 0.000
0.000
0.325 0.202
0.140 T17 140'-120' A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
79.633
39.454
33.553
0.000
0.000
0.000
0.327
0.202
0.140 T18 120'-100' A
B C
0.000
0.000 0.000
0.000
0.000 0.000
79.633
39.454 33.553
0.000
0.000 0.000
0.327
0.202 0.140
T19 100'-80' A
B C
0.000
0.000 0.000
0.000
0.000 0.000
79.633
39.454 33.553
0.000
0.000 0.000
0.327
0.202 0.140
T20 80'-60' A B
C
0.000 0.000
0.000
0.000 0.000
0.000
79.633 39.454
33.553
0.000 0.000
0.000
0.327 0.202
0.140
T21 60'-40' A B
C
0.000 0.000
0.000
0.000 0.000
0.000
79.633 39.454
33.553
0.000 0.000
0.000
0.327 0.202
0.140
T22 40'-20' A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
79.633
39.454
33.553
0.000
0.000
0.000
0.327
0.202
0.140 T23 20'-8' A
B C
0.000
0.000 0.000
0.000
0.000 0.000
47.780
23.672 20.132
0.000
0.000 0.000
0.196
0.121 0.084
T24 8'-0' A
B C
0.000
0.000 0.000
0.000
0.000 0.000
31.853
15.782 13.421
0.000
0.000 0.000
0.131
0.081 0.056
Feed Line Center of Pressure
Section Elevation
ft
CPX
in
CPZ
in
CPX
Ice
in
CPZ
Ice
in
T1 300'-296' 2.131 -1.133 1.742 -0.888
T2 296'-292' 2.248 -1.195 1.858 -0.948
T3 292'-288' 2.250 -1.196 1.858 -0.948
T4 288'-284' 2.090 -0.742 1.717 -0.438 T5 284'-280' 1.727 0.171 1.415 0.509
T6 280'-276' 1.598 0.157 1.295 0.465 T7 276'-272' 1.658 0.161 1.349 0.485
T8 272'-268' 1.639 0.158 1.330 0.478
T9 268'-264' 1.696 0.163 1.383 0.497 T10 264'-260' 1.588 0.151 1.282 0.461
T11 260'-240' 1.594 -0.066 1.266 0.238 T12 240'-220' 1.134 -0.778 0.793 -0.596
T13 220'-200' 1.016 -0.990 0.671 -0.838
T14 200'-180' 0.656 -0.818 0.656 -0.818 T15 180'-160' 0.650 -0.811 0.650 -0.811
Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
14 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Section Elevation
ft
CPX
in
CPZ
in
CPX
Ice
in
CPZ
Ice
in
T16 160'-140' 0.652 -0.851 0.652 -0.851 T17 140'-120' 0.650 -0.877 0.650 -0.877
T18 120'-100' 0.665 -0.898 0.665 -0.898 T19 100'-80' 0.659 -0.889 0.659 -0.889
T20 80'-60' 0.657 -0.887 0.657 -0.887
T21 60'-40' 0.655 -0.884 0.655 -0.884 T22 40'-20' 0.655 -0.884 0.655 -0.884
T23 20'-8' 0.670 -0.905 0.670 -0.905 T24 8'-0' 0.000 0.000 0.000 0.000
Shielding Factor Ka
Tower Section
Feed Line Record No.
Description Feed Line Segment Elev.
Ka No Ice
Ka Ice
T1 8 LDF4-50A(1/2") 296.00 - 300.00 0.6000 0.6000
T1 11 LDF12-50A(2-1/4") 296.00 - 300.00 1.0000 0.6000 T1 12 WR-VG86ST-BRD( 3/4) 296.00 - 300.00 0.6000 0.6000
T1 13 FB-L98B-034-XXXXXX( 3/8) 296.00 - 300.00 0.6000 0.6000 T1 18 Safety Line 3/8 296.00 - 300.00 0.6000 0.6000
T1 20 ROHN Waveguide Brackets 296.00 - 300.00 0.6000 0.6000
T1 21 ROHN Waveguide Brackets 296.00 - 300.00 0.6000 0.6000 T1 22 ROHN Waveguide Brackets 296.00 - 300.00 0.6000 0.6000
T2 8 LDF4-50A(1/2") 292.00 - 296.00 0.6000 0.6000 T2 11 LDF12-50A(2-1/4") 292.00 - 296.00 1.0000 0.6000
T2 12 WR-VG86ST-BRD( 3/4) 292.00 - 296.00 0.6000 0.6000
T2 13 FB-L98B-034-XXXXXX( 3/8) 292.00 - 296.00 0.6000 0.6000 T2 18 Safety Line 3/8 292.00 - 296.00 0.6000 0.6000
T2 20 ROHN Waveguide Brackets 292.00 - 296.00 0.6000 0.6000
T2 21 ROHN Waveguide Brackets 292.00 - 296.00 0.6000 0.6000 T2 22 ROHN Waveguide Brackets 292.00 - 296.00 0.6000 0.6000
T3 8 LDF4-50A(1/2") 288.00 - 292.00 0.6000 0.6000 T3 11 LDF12-50A(2-1/4") 288.00 - 292.00 1.0000 0.6000
T3 12 WR-VG86ST-BRD( 3/4) 288.00 - 292.00 0.6000 0.6000
T3 13 FB-L98B-034-XXXXXX( 3/8) 288.00 - 292.00 0.6000 0.6000 T3 18 Safety Line 3/8 288.00 - 292.00 0.6000 0.6000
T3 20 ROHN Waveguide Brackets 288.00 - 292.00 0.6000 0.6000 T3 21 ROHN Waveguide Brackets 288.00 - 292.00 0.6000 0.6000
T3 22 ROHN Waveguide Brackets 288.00 - 292.00 0.6000 0.6000
T4 2 LDF7-50A(1-5/8") 284.00 - 285.00 0.6000 0.6000 T4 8 LDF4-50A(1/2") 284.00 - 288.00 0.6000 0.6000
T4 11 LDF12-50A(2-1/4") 284.00 - 288.00 1.0000 0.6000
T4 12 WR-VG86ST-BRD( 3/4) 284.00 - 288.00 0.6000 0.6000
T4 13 FB-L98B-034-XXXXXX( 3/8) 284.00 - 288.00 0.6000 0.6000
T4 15 LDF7-50A(1-5/8") 284.00 - 285.00 0.6000 0.6000 T4 18 Safety Line 3/8 284.00 - 288.00 0.6000 0.6000
T4 20 ROHN Waveguide Brackets 284.00 - 288.00 0.6000 0.6000 T4 21 ROHN Waveguide Brackets 284.00 - 288.00 0.6000 0.6000
T4 22 ROHN Waveguide Brackets 284.00 - 288.00 0.6000 0.6000
T5 2 LDF7-50A(1-5/8") 280.00 - 284.00 0.6000 0.6000 T5 8 LDF4-50A(1/2") 280.00 - 284.00 0.6000 0.6000
T5 11 LDF12-50A(2-1/4") 280.00 - 284.00 1.0000 0.6000 T5 12 WR-VG86ST-BRD( 3/4) 280.00 - 284.00 0.6000 0.6000
T5 13 FB-L98B-034-XXXXXX( 3/8) 280.00 - 284.00 0.6000 0.6000
T5 15 LDF7-50A(1-5/8") 280.00 - 284.00 0.6000 0.6000 T5 18 Safety Line 3/8 280.00 - 284.00 0.6000 0.6000
Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
15 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Tower Section
Feed Line Record No.
Description Feed Line Segment Elev.
Ka No Ice
Ka Ice
T5 20 ROHN Waveguide Brackets 280.00 - 284.00 0.6000 0.6000
T5 21 ROHN Waveguide Brackets 280.00 - 284.00 0.6000 0.6000 T5 22 ROHN Waveguide Brackets 280.00 - 284.00 0.6000 0.6000
T6 2 LDF7-50A(1-5/8") 276.00 - 280.00 0.6000 0.6000 T6 8 LDF4-50A(1/2") 276.00 - 280.00 0.6000 0.6000
T6 11 LDF12-50A(2-1/4") 276.00 - 280.00 1.0000 0.6000
T6 12 WR-VG86ST-BRD( 3/4) 276.00 - 280.00 0.6000 0.6000 T6 13 FB-L98B-034-XXXXXX( 3/8) 276.00 - 280.00 0.6000 0.6000
T6 15 LDF7-50A(1-5/8") 276.00 - 280.00 0.6000 0.6000 T6 18 Safety Line 3/8 276.00 - 280.00 0.6000 0.6000
T6 20 ROHN Waveguide Brackets 276.00 - 280.00 0.6000 0.6000
T6 21 ROHN Waveguide Brackets 276.00 - 280.00 0.6000 0.6000 T6 22 ROHN Waveguide Brackets 276.00 - 280.00 0.6000 0.6000
T7 2 LDF7-50A(1-5/8") 272.00 - 276.00 0.6000 0.6000 T7 8 LDF4-50A(1/2") 272.00 - 276.00 0.6000 0.6000
T7 11 LDF12-50A(2-1/4") 272.00 - 276.00 1.0000 0.6000
T7 12 WR-VG86ST-BRD( 3/4) 272.00 - 276.00 0.6000 0.6000 T7 13 FB-L98B-034-XXXXXX( 3/8) 272.00 - 276.00 0.6000 0.6000
T7 15 LDF7-50A(1-5/8") 272.00 - 276.00 0.6000 0.6000 T7 18 Safety Line 3/8 272.00 - 276.00 0.6000 0.6000
T7 20 ROHN Waveguide Brackets 272.00 - 276.00 0.6000 0.6000
T7 21 ROHN Waveguide Brackets 272.00 - 276.00 0.6000 0.6000 T7 22 ROHN Waveguide Brackets 272.00 - 276.00 0.6000 0.6000
T8 2 LDF7-50A(1-5/8") 268.00 - 272.00 0.6000 0.6000 T8 8 LDF4-50A(1/2") 268.00 - 272.00 0.6000 0.6000
T8 11 LDF12-50A(2-1/4") 268.00 - 272.00 1.0000 0.6000
T8 12 WR-VG86ST-BRD( 3/4) 268.00 - 272.00 0.6000 0.6000 T8 13 FB-L98B-034-XXXXXX( 3/8) 268.00 - 272.00 0.6000 0.6000
T8 15 LDF7-50A(1-5/8") 268.00 - 272.00 0.6000 0.6000
T8 18 Safety Line 3/8 268.00 - 272.00 0.6000 0.6000
T8 20 ROHN Waveguide Brackets 268.00 - 272.00 0.6000 0.6000
T8 21 ROHN Waveguide Brackets 268.00 - 272.00 0.6000 0.6000 T8 22 ROHN Waveguide Brackets 268.00 - 272.00 0.6000 0.6000
T9 2 LDF7-50A(1-5/8") 264.00 - 268.00 0.6000 0.6000 T9 8 LDF4-50A(1/2") 264.00 - 268.00 0.6000 0.6000
T9 11 LDF12-50A(2-1/4") 264.00 - 268.00 1.0000 0.6000
T9 12 WR-VG86ST-BRD( 3/4) 264.00 - 268.00 0.6000 0.6000 T9 13 FB-L98B-034-XXXXXX( 3/8) 264.00 - 268.00 0.6000 0.6000
T9 15 LDF7-50A(1-5/8") 264.00 - 268.00 0.6000 0.6000 T9 18 Safety Line 3/8 264.00 - 268.00 0.6000 0.6000
T9 20 ROHN Waveguide Brackets 264.00 - 268.00 0.6000 0.6000
T9 21 ROHN Waveguide Brackets 264.00 - 268.00 0.6000 0.6000 T9 22 ROHN Waveguide Brackets 264.00 - 268.00 0.6000 0.6000
T10 2 LDF7-50A(1-5/8") 260.00 - 264.00 0.6000 0.6000 T10 8 LDF4-50A(1/2") 260.00 - 264.00 0.6000 0.6000
T10 11 LDF12-50A(2-1/4") 260.00 - 264.00 1.0000 0.6000
T10 12 WR-VG86ST-BRD( 3/4) 260.00 - 264.00 0.6000 0.6000 T10 13 FB-L98B-034-XXXXXX( 3/8) 260.00 - 264.00 0.6000 0.6000
T10 15 LDF7-50A(1-5/8") 260.00 - 264.00 0.6000 0.6000 T10 18 Safety Line 3/8 260.00 - 264.00 0.6000 0.6000
T10 20 ROHN Waveguide Brackets 260.00 - 264.00 0.6000 0.6000
T10 21 ROHN Waveguide Brackets 260.00 - 264.00 0.6000 0.6000 T10 22 ROHN Waveguide Brackets 260.00 - 264.00 0.6000 0.6000
T11 2 LDF7-50A(1-5/8") 240.00 - 260.00 0.6000 0.6000 T11 5 LDF7-50A(1-5/8") 240.00 - 245.00 0.6000 0.6000
T11 8 LDF4-50A(1/2") 240.00 - 260.00 0.6000 0.6000
T11 11 LDF12-50A(2-1/4") 240.00 - 260.00 1.0000 0.6000 T11 12 WR-VG86ST-BRD( 3/4) 240.00 - 260.00 0.6000 0.6000
T11 13 FB-L98B-034-XXXXXX( 3/8) 240.00 - 260.00 0.6000 0.6000
T11 15 LDF7-50A(1-5/8") 240.00 - 260.00 0.6000 0.6000 T11 18 Safety Line 3/8 240.00 - 260.00 0.6000 0.6000
T11 20 ROHN Waveguide Brackets 240.00 - 260.00 0.6000 0.6000
Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
16 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Tower Section
Feed Line Record No.
Description Feed Line Segment Elev.
Ka No Ice
Ka Ice
T11 21 ROHN Waveguide Brackets 240.00 - 260.00 0.6000 0.6000
T11 22 ROHN Waveguide Brackets 240.00 - 260.00 0.6000 0.6000 T12 2 LDF7-50A(1-5/8") 220.00 - 240.00 0.6000 0.6000
T12 4 LDF7-50A(1-5/8") 220.00 - 227.00 0.6000 0.6000 T12 5 LDF7-50A(1-5/8") 227.00 - 240.00 0.6000 0.6000
T12 8 LDF4-50A(1/2") 220.00 - 240.00 0.6000 0.6000
T12 11 LDF12-50A(2-1/4") 220.00 - 240.00 1.0000 0.6000 T12 12 WR-VG86ST-BRD( 3/4) 220.00 - 240.00 0.6000 0.6000
T12 13 FB-L98B-034-XXXXXX( 3/8) 220.00 - 240.00 0.6000 0.6000 T12 15 LDF7-50A(1-5/8") 220.00 - 240.00 0.6000 0.6000
T12 18 Safety Line 3/8 220.00 - 240.00 0.6000 0.6000
T12 20 ROHN Waveguide Brackets 220.00 - 240.00 0.6000 0.6000 T12 21 ROHN Waveguide Brackets 220.00 - 240.00 0.6000 0.6000
T12 22 ROHN Waveguide Brackets 220.00 - 240.00 0.6000 0.6000 T13 2 LDF7-50A(1-5/8") 200.00 - 220.00 0.6000 0.6000
T13 4 LDF7-50A(1-5/8") 200.00 - 220.00 0.6000 0.6000
T13 8 LDF4-50A(1/2") 200.00 - 220.00 0.6000 0.6000 T13 11 LDF12-50A(2-1/4") 200.00 - 220.00 1.0000 0.6000
T13 12 WR-VG86ST-BRD( 3/4) 200.00 - 220.00 0.6000 0.6000 T13 13 FB-L98B-034-XXXXXX( 3/8) 200.00 - 220.00 0.6000 0.6000
T13 15 LDF7-50A(1-5/8") 200.00 - 220.00 0.6000 0.6000
T13 18 Safety Line 3/8 200.00 - 220.00 0.6000 0.6000 T13 20 ROHN Waveguide Brackets 200.00 - 220.00 0.6000 0.6000
T13 21 ROHN Waveguide Brackets 200.00 - 220.00 0.6000 0.6000 T13 22 ROHN Waveguide Brackets 200.00 - 220.00 0.6000 0.6000
T14 2 LDF7-50A(1-5/8") 180.00 - 200.00 0.6000 0.6000
T14 4 LDF7-50A(1-5/8") 180.00 - 200.00 0.6000 0.6000 T14 8 LDF4-50A(1/2") 180.00 - 200.00 0.6000 0.6000
T14 11 LDF12-50A(2-1/4") 180.00 - 200.00 0.6000 0.6000
T14 12 WR-VG86ST-BRD( 3/4) 180.00 - 200.00 0.6000 0.6000
T14 13 FB-L98B-034-XXXXXX( 3/8) 180.00 - 200.00 0.6000 0.6000
T14 15 LDF7-50A(1-5/8") 180.00 - 200.00 0.6000 0.6000 T14 18 Safety Line 3/8 180.00 - 200.00 0.6000 0.6000
T14 20 ROHN Waveguide Brackets 180.00 - 200.00 0.6000 0.6000 T14 21 ROHN Waveguide Brackets 180.00 - 200.00 0.6000 0.6000
T14 22 ROHN Waveguide Brackets 180.00 - 200.00 0.6000 0.6000
T15 2 LDF7-50A(1-5/8") 160.00 - 180.00 0.6000 0.6000 T15 4 LDF7-50A(1-5/8") 160.00 - 180.00 0.6000 0.6000
T15 8 LDF4-50A(1/2") 160.00 - 180.00 0.6000 0.6000 T15 11 LDF12-50A(2-1/4") 160.00 - 180.00 0.6000 0.6000
T15 12 WR-VG86ST-BRD( 3/4) 160.00 - 180.00 0.6000 0.6000
T15 13 FB-L98B-034-XXXXXX( 3/8) 160.00 - 180.00 0.6000 0.6000 T15 15 LDF7-50A(1-5/8") 160.00 - 180.00 0.6000 0.6000
T15 18 Safety Line 3/8 160.00 - 180.00 0.6000 0.6000 T15 20 ROHN Waveguide Brackets 160.00 - 180.00 0.6000 0.6000
T15 21 ROHN Waveguide Brackets 160.00 - 180.00 0.6000 0.6000
T15 22 ROHN Waveguide Brackets 160.00 - 180.00 0.6000 0.6000 T16 2 LDF7-50A(1-5/8") 140.00 - 160.00 0.6000 0.6000
T16 4 LDF7-50A(1-5/8") 140.00 - 160.00 0.6000 0.6000 T16 7 LDF4-50A(1/2") 140.00 - 151.00 0.6000 0.6000
T16 8 LDF4-50A(1/2") 151.00 - 160.00 0.6000 0.6000
T16 11 LDF12-50A(2-1/4") 140.00 - 160.00 0.6000 0.6000 T16 12 WR-VG86ST-BRD( 3/4) 140.00 - 160.00 0.6000 0.6000
T16 13 FB-L98B-034-XXXXXX( 3/8) 140.00 - 160.00 0.6000 0.6000 T16 15 LDF7-50A(1-5/8") 140.00 - 160.00 0.6000 0.6000
T16 18 Safety Line 3/8 140.00 - 160.00 0.6000 0.6000
T16 20 ROHN Waveguide Brackets 140.00 - 160.00 0.6000 0.6000 T16 21 ROHN Waveguide Brackets 140.00 - 160.00 0.6000 0.6000
T16 22 ROHN Waveguide Brackets 140.00 - 160.00 0.6000 0.6000
T17 2 LDF7-50A(1-5/8") 120.00 - 140.00 0.6000 0.6000 T17 4 LDF7-50A(1-5/8") 120.00 - 140.00 0.6000 0.6000
T17 7 LDF4-50A(1/2") 120.00 - 140.00 0.6000 0.6000
Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
17 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Tower Section
Feed Line Record No.
Description Feed Line Segment Elev.
Ka No Ice
Ka Ice
T17 11 LDF12-50A(2-1/4") 120.00 - 140.00 0.6000 0.6000
T17 12 WR-VG86ST-BRD( 3/4) 120.00 - 140.00 0.6000 0.6000 T17 13 FB-L98B-034-XXXXXX( 3/8) 120.00 - 140.00 0.6000 0.6000
T17 15 LDF7-50A(1-5/8") 120.00 - 140.00 0.6000 0.6000 T17 18 Safety Line 3/8 120.00 - 140.00 0.6000 0.6000
T17 20 ROHN Waveguide Brackets 120.00 - 140.00 0.6000 0.6000
T17 21 ROHN Waveguide Brackets 120.00 - 140.00 0.6000 0.6000 T17 22 ROHN Waveguide Brackets 120.00 - 140.00 0.6000 0.6000
T18 2 LDF7-50A(1-5/8") 100.00 - 120.00 0.6000 0.6000 T18 4 LDF7-50A(1-5/8") 100.00 - 120.00 0.6000 0.6000
T18 7 LDF4-50A(1/2") 100.00 - 120.00 0.6000 0.6000
T18 11 LDF12-50A(2-1/4") 100.00 - 120.00 0.6000 0.6000 T18 12 WR-VG86ST-BRD( 3/4) 100.00 - 120.00 0.6000 0.6000
T18 13 FB-L98B-034-XXXXXX( 3/8) 100.00 - 120.00 0.6000 0.6000 T18 15 LDF7-50A(1-5/8") 100.00 - 120.00 0.6000 0.6000
T18 18 Safety Line 3/8 100.00 - 120.00 0.6000 0.6000
T18 20 ROHN Waveguide Brackets 100.00 - 120.00 0.6000 0.6000 T18 21 ROHN Waveguide Brackets 100.00 - 120.00 0.6000 0.6000
T18 22 ROHN Waveguide Brackets 100.00 - 120.00 0.6000 0.6000 T19 2 LDF7-50A(1-5/8") 80.00 - 100.00 0.6000 0.6000
T19 4 LDF7-50A(1-5/8") 80.00 - 100.00 0.6000 0.6000
T19 7 LDF4-50A(1/2") 80.00 - 100.00 0.6000 0.6000 T19 11 LDF12-50A(2-1/4") 80.00 - 100.00 0.6000 0.6000
T19 12 WR-VG86ST-BRD( 3/4) 80.00 - 100.00 0.6000 0.6000 T19 13 FB-L98B-034-XXXXXX( 3/8) 80.00 - 100.00 0.6000 0.6000
T19 15 LDF7-50A(1-5/8") 80.00 - 100.00 0.6000 0.6000
T19 18 Safety Line 3/8 80.00 - 100.00 0.6000 0.6000 T19 20 ROHN Waveguide Brackets 80.00 - 100.00 0.6000 0.6000
T19 21 ROHN Waveguide Brackets 80.00 - 100.00 0.6000 0.6000
T19 22 ROHN Waveguide Brackets 80.00 - 100.00 0.6000 0.6000
T20 2 LDF7-50A(1-5/8") 60.00 - 80.00 0.6000 0.6000
T20 4 LDF7-50A(1-5/8") 60.00 - 80.00 0.6000 0.6000 T20 7 LDF4-50A(1/2") 60.00 - 80.00 0.6000 0.6000
T20 11 LDF12-50A(2-1/4") 60.00 - 80.00 0.6000 0.6000 T20 12 WR-VG86ST-BRD( 3/4) 60.00 - 80.00 0.6000 0.6000
T20 13 FB-L98B-034-XXXXXX( 3/8) 60.00 - 80.00 0.6000 0.6000
T20 15 LDF7-50A(1-5/8") 60.00 - 80.00 0.6000 0.6000 T20 18 Safety Line 3/8 60.00 - 80.00 0.6000 0.6000
T20 20 ROHN Waveguide Brackets 60.00 - 80.00 0.6000 0.6000 T20 21 ROHN Waveguide Brackets 60.00 - 80.00 0.6000 0.6000
T20 22 ROHN Waveguide Brackets 60.00 - 80.00 0.6000 0.6000
T21 2 LDF7-50A(1-5/8") 40.00 - 60.00 0.6000 0.6000 T21 4 LDF7-50A(1-5/8") 40.00 - 60.00 0.6000 0.6000
T21 7 LDF4-50A(1/2") 40.00 - 60.00 0.6000 0.6000 T21 11 LDF12-50A(2-1/4") 40.00 - 60.00 0.6000 0.6000
T21 12 WR-VG86ST-BRD( 3/4) 40.00 - 60.00 0.6000 0.6000
T21 13 FB-L98B-034-XXXXXX( 3/8) 40.00 - 60.00 0.6000 0.6000 T21 15 LDF7-50A(1-5/8") 40.00 - 60.00 0.6000 0.6000
T21 18 Safety Line 3/8 40.00 - 60.00 0.6000 0.6000 T21 20 ROHN Waveguide Brackets 40.00 - 60.00 0.6000 0.6000
T21 21 ROHN Waveguide Brackets 40.00 - 60.00 0.6000 0.6000
T21 22 ROHN Waveguide Brackets 40.00 - 60.00 0.6000 0.6000 T22 2 LDF7-50A(1-5/8") 20.00 - 40.00 0.6000 0.6000
T22 4 LDF7-50A(1-5/8") 20.00 - 40.00 0.6000 0.6000 T22 7 LDF4-50A(1/2") 20.00 - 40.00 0.6000 0.6000
T22 11 LDF12-50A(2-1/4") 20.00 - 40.00 0.6000 0.6000
T22 12 WR-VG86ST-BRD( 3/4) 20.00 - 40.00 0.6000 0.6000 T22 13 FB-L98B-034-XXXXXX( 3/8) 20.00 - 40.00 0.6000 0.6000
T22 15 LDF7-50A(1-5/8") 20.00 - 40.00 0.6000 0.6000
T22 18 Safety Line 3/8 20.00 - 40.00 0.6000 0.6000 T22 20 ROHN Waveguide Brackets 20.00 - 40.00 0.6000 0.6000
T22 21 ROHN Waveguide Brackets 20.00 - 40.00 0.6000 0.6000
Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
18 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Tower Section
Feed Line Record No.
Description Feed Line Segment Elev.
Ka No Ice
Ka Ice
T22 22 ROHN Waveguide Brackets 20.00 - 40.00 0.6000 0.6000
T23 2 LDF7-50A(1-5/8") 8.00 - 20.00 0.6000 0.6000 T23 4 LDF7-50A(1-5/8") 8.00 - 20.00 0.6000 0.6000
T23 7 LDF4-50A(1/2") 8.00 - 20.00 0.6000 0.6000 T23 11 LDF12-50A(2-1/4") 8.00 - 20.00 0.6000 0.6000
T23 12 WR-VG86ST-BRD( 3/4) 8.00 - 20.00 0.6000 0.6000
T23 13 FB-L98B-034-XXXXXX( 3/8) 8.00 - 20.00 0.6000 0.6000 T23 15 LDF7-50A(1-5/8") 8.00 - 20.00 0.6000 0.6000
T23 18 Safety Line 3/8 8.00 - 20.00 0.6000 0.6000 T23 20 ROHN Waveguide Brackets 8.00 - 20.00 0.6000 0.6000
T23 21 ROHN Waveguide Brackets 8.00 - 20.00 0.6000 0.6000
T23 22 ROHN Waveguide Brackets 8.00 - 20.00 0.6000 0.6000 T24 2 LDF7-50A(1-5/8") 0.00 - 8.00 0.0000 0.0000
T24 4 LDF7-50A(1-5/8") 0.00 - 8.00 0.0000 0.0000 T24 7 LDF4-50A(1/2") 0.00 - 8.00 0.0000 0.0000
T24 11 LDF12-50A(2-1/4") 0.00 - 8.00 0.0000 0.0000
T24 12 WR-VG86ST-BRD( 3/4) 0.00 - 8.00 0.0000 0.0000 T24 13 FB-L98B-034-XXXXXX( 3/8) 0.00 - 8.00 0.0000 0.0000
T24 15 LDF7-50A(1-5/8") 0.00 - 8.00 0.0000 0.0000 T24 18 Safety Line 3/8 0.00 - 8.00 0.0000 0.0000
T24 20 ROHN Waveguide Brackets 0.00 - 8.00 0.0000 0.0000
T24 21 ROHN Waveguide Brackets 0.00 - 8.00 0.0000 0.0000 T24 22 ROHN Waveguide Brackets 0.00 - 8.00 0.0000 0.0000
Discrete Tower Loads
Description Face or
Leg
Offset Type
Offsets: Horz
Lateral Vert
ft
ft ft
Azimuth Adjustment
°
Placement
ft
CAAA Front
ft2
CAAA Side
ft2
Weight
K
Lightning Rod 5/8'' x 3' on 7'
Mount Pipe (E)
C From Leg 0.000
0' 5'
0.000 300' No Ice 1.850 1.850 0.036
Flash Beacon Lighting (E)
A From Leg 0.000 0'
1'
0.000 300' No Ice 2.700 2.700 0.050
Side Lighting (E)
A From Leg 0.500 0'
0'
0.000 151' No Ice 0.133 0.133 0.005
Side Lighting
(E)
B From Leg 0.500
0'
0'
0.000 151' No Ice 0.133 0.133 0.005
Side Lighting
(E)
C From Leg 0.500
0' 0'
0.000 151' No Ice 0.133 0.133 0.005
**/>**
SBNHH-1D65C w/ Mount Pipe
(R)
A From Leg 4.000 0'
0'
0.000 300' No Ice 11.588 9.793 0.099
SBNHH-1D65C w/ Mount
Pipe
(R)
C From Leg 4.000
0'
0'
0.000 300' No Ice 11.588 9.793 0.099
SBNHH-1D65C w/ Mount
Pipe (R)
B From Leg 4.000
0' 0'
0.000 300' No Ice 11.588 9.793 0.099 Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
19 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Description Face or
Leg
Offset Type
Offsets: Horz
Lateral Vert
ft
ft ft
Azimuth Adjustment
°
Placement
ft
CAAA Front
ft2
CAAA Side
ft2
Weight
K
742 352 w/ Mount Pipe
(R)
A From Leg 4.000
0' 0'
0.000 300' No Ice 6.646 3.066 0.056
742 352 w/ Mount Pipe (R)
B From Leg 4.000 0'
0'
0.000 300' No Ice 6.646 3.066 0.056
742 352 w/ Mount Pipe (R)
C From Leg 4.000 0'
0'
0.000 300' No Ice 6.646 3.066 0.056
(2) RRUS 11
(R)
A From Leg 4.000
0'
0'
0.000 300' No Ice 3.249 1.373 0.048
(2) RRUS 11
(R)
B From Leg 4.000
0' 0'
0.000 300' No Ice 3.249 1.373 0.048
(2) RRUS 11
(R)
C From Leg 4.000
0' 0'
0.000 300' No Ice 3.249 1.373 0.048
DC6-48-60-18-8F (R)
B From Leg 4.000 0'
0'
0.000 300' No Ice 1.467 1.467 0.019
Sector Mount [SM 1303-3] (R)
C None 0.000 300' No Ice 30.200 30.200 1.104
**/>**
**/>**
BXA-70080-8CF-EDIN-2 w/
Mount Pipe (E)
A From Leg 4.000
0' 0'
0.000 285' No Ice 8.441 8.703 0.055
BXA-70080-8CF-EDIN-2 w/ Mount Pipe
(E)
B From Leg 4.000 0'
0'
0.000 285' No Ice 8.441 8.703 0.055
BXA-70080-8CF-EDIN-2 w/ Mount Pipe
(E)
C From Leg 4.000 0'
0'
0.000 285' No Ice 8.441 8.703 0.055
(2) FD9R6004
(E)
A From Leg 4.000
0'
0'
0.000 285' No Ice 0.367 0.085 0.003
(2) FD9R6004
(E)
B From Leg 4.000
0' 0'
0.000 285' No Ice 0.367 0.085 0.003
(2) FD9R6004
(E)
C From Leg 4.000
0' 0'
0.000 285' No Ice 0.367 0.085 0.003
X7C-FRO-860-VR0 (P)
A From Leg 4.000 0'
0'
0.000 285' No Ice 13.627 8.511 0.050
X7C-FRO-860-VR0 (P)
B From Leg 4.000 0'
0'
0.000 285' No Ice 13.627 8.511 0.050
X7C-FRO-860-VR0
(P)
C From Leg 4.000
0'
0'
0.000 285' No Ice 13.627 8.511 0.050
HBXX-6516DS-A2M
(P)
A From Leg 4.000
0'
0'
0.000 285' No Ice 5.938 3.280 0.031
HBXX-6516DS-A2M
(P)
B From Leg 4.000
0'
0.000 285' No Ice 5.938 3.280 0.031
Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
20 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Description Face or
Leg
Offset Type
Offsets: Horz
Lateral Vert
ft
ft ft
Azimuth Adjustment
°
Placement
ft
CAAA Front
ft2
CAAA Side
ft2
Weight
K
0'
HBXX-6516DS-A2M (P)
C From Leg 4.000 0'
0'
0.000 285' No Ice 5.938 3.280 0.031
RHSDC-3315-PF-48
(P)
A From Leg 4.000
0'
0'
0.000 285' No Ice 4.326 2.557 0.032
RRUS12/RRUS A2
(P)
A From Leg 4.000
0' 0'
0.000 285' No Ice 3.667 2.141 0.072
RRUS12/RRUS A2
(P)
B From Leg 4.000
0' 0'
0.000 285' No Ice 3.667 2.141 0.072
RRUS12/RRUS A2 (P)
C From Leg 4.000 0'
0'
0.000 285' No Ice 3.667 2.141 0.072
6' x 2'' Mount Pipe (E)
A From Leg 4.000 0'
0'
0.000 285' No Ice 1.425 1.425 0.022
6' x 2'' Mount Pipe
(E)
B From Leg 4.000
0'
0'
0.000 285' No Ice 1.425 1.425 0.022
6' x 2'' Mount Pipe
(E)
C From Leg 4.000
0'
0'
0.000 285' No Ice 1.425 1.425 0.022
Sector Mount [SM 402-3]
(E-2 Pipes/Sector)
C None 0.000 285' No Ice 18.910 18.910 0.851
**/>**
**/>** (2) RV65-18-02DPL2 w/
Mount Pipe
(E)
A From Leg 0.500
0'
0'
0.000 245' No Ice 3.537 3.294 0.031
(2) AP18-1900/063D w/
Mount Pipe (E)
B From Leg 0.500
0' 0'
0.000 245' No Ice 3.397 2.258 0.029
(2) AP18-1900/063D w/
Mount Pipe (E)
C From Leg 0.500
0' 0'
0.000 245' No Ice 3.397 2.258 0.029
Sector Mount [SM 501-3] (E)
C None 0.000 245' No Ice 24.210 24.210 0.900
**/>**
(2) 58010 w/ Mount Pipe (E)
A From Leg 4.000 0'
2'
0.000 227' No Ice 3.616 3.116 0.031
(2) 58010 w/ Mount Pipe
(E)
B From Leg 4.000
0'
2'
0.000 227' No Ice 3.616 3.116 0.031
(2) 58010 w/ Mount Pipe
(E)
C From Leg 4.000
0' 2'
0.000 227' No Ice 3.616 3.116 0.031
(2) LGP 13904
(E)
A From Leg 4.000
0' 2'
0.000 227' No Ice 0.586 0.280 0.010
(2) LGP 13904
(E)
B From Leg 4.000
0' 2'
0.000 227' No Ice 0.586 0.280 0.010
(2) LGP 13904 C From Leg 4.000 0.000 227' No Ice 0.586 0.280 0.010
Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
21 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Description Face or
Leg
Offset Type
Offsets: Horz
Lateral Vert
ft
ft ft
Azimuth Adjustment
°
Placement
ft
CAAA Front
ft2
CAAA Side
ft2
Weight
K
(E) 0'
2' 6' x 2'' Mount Pipe
(E)
A From Leg 4.000
0' 0'
0.000 227' No Ice 1.425 1.425 0.022
6' x 2'' Mount Pipe
(E)
B From Leg 4.000
0' 0'
0.000 227' No Ice 1.425 1.425 0.022
6' x 2'' Mount Pipe (E)
C From Leg 4.000 0'
0'
0.000 227' No Ice 1.425 1.425 0.022
Sector Mount [SM 502-3] (E)
C None 0.000 227' No Ice 33.020 33.020 1.673
**/>**
Load Combinations
Comb.
No.
Description
1 Dead Only
2 1.2 Dead+1.6 Wind 0 deg - No Ice+1.0 Guy
3 1.2D+1.6W (pattern 1) 0 deg - No Ice+1.0 Guy
4 1.2D+1.6W (pattern 2) 0 deg - No Ice+1.0 Guy 5 1.2D+1.6W (pattern 3) 0 deg - No Ice+1.0 Guy
6 1.2D+1.6W (pattern 4) 0 deg - No Ice+1.0 Guy 7 1.2 Dead+1.6 Wind 30 deg - No Ice+1.0 Guy
8 1.2D+1.6W (pattern 1) 30 deg - No Ice+1.0 Guy
9 1.2D+1.6W (pattern 2) 30 deg - No Ice+1.0 Guy 10 1.2D+1.6W (pattern 3) 30 deg - No Ice+1.0 Guy
11 1.2D+1.6W (pattern 4) 30 deg - No Ice+1.0 Guy 12 1.2 Dead+1.6 Wind 60 deg - No Ice+1.0 Guy
13 1.2D+1.6W (pattern 1) 60 deg - No Ice+1.0 Guy
14 1.2D+1.6W (pattern 2) 60 deg - No Ice+1.0 Guy 15 1.2D+1.6W (pattern 3) 60 deg - No Ice+1.0 Guy
16 1.2D+1.6W (pattern 4) 60 deg - No Ice+1.0 Guy 17 1.2 Dead+1.6 Wind 90 deg - No Ice+1.0 Guy
18 1.2D+1.6W (pattern 1) 90 deg - No Ice+1.0 Guy
19 1.2D+1.6W (pattern 2) 90 deg - No Ice+1.0 Guy 20 1.2D+1.6W (pattern 3) 90 deg - No Ice+1.0 Guy
21 1.2D+1.6W (pattern 4) 90 deg - No Ice+1.0 Guy 22 1.2 Dead+1.6 Wind 120 deg - No Ice+1.0 Guy
23 1.2D+1.6W (pattern 1) 120 deg - No Ice+1.0 Guy
24 1.2D+1.6W (pattern 2) 120 deg - No Ice+1.0 Guy 25 1.2D+1.6W (pattern 3) 120 deg - No Ice+1.0 Guy
26 1.2D+1.6W (pattern 4) 120 deg - No Ice+1.0 Guy 27 1.2 Dead+1.6 Wind 150 deg - No Ice+1.0 Guy
28 1.2D+1.6W (pattern 1) 150 deg - No Ice+1.0 Guy
29 1.2D+1.6W (pattern 2) 150 deg - No Ice+1.0 Guy 30 1.2D+1.6W (pattern 3) 150 deg - No Ice+1.0 Guy
31 1.2D+1.6W (pattern 4) 150 deg - No Ice+1.0 Guy 32 1.2 Dead+1.6 Wind 180 deg - No Ice+1.0 Guy
33 1.2D+1.6W (pattern 1) 180 deg - No Ice+1.0 Guy
Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
22 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Comb. No.
Description
34 1.2D+1.6W (pattern 2) 180 deg - No Ice+1.0 Guy
35 1.2D+1.6W (pattern 3) 180 deg - No Ice+1.0 Guy 36 1.2D+1.6W (pattern 4) 180 deg - No Ice+1.0 Guy
37 1.2 Dead+1.6 Wind 210 deg - No Ice+1.0 Guy 38 1.2D+1.6W (pattern 1) 210 deg - No Ice+1.0 Guy
39 1.2D+1.6W (pattern 2) 210 deg - No Ice+1.0 Guy
40 1.2D+1.6W (pattern 3) 210 deg - No Ice+1.0 Guy 41 1.2D+1.6W (pattern 4) 210 deg - No Ice+1.0 Guy
42 1.2 Dead+1.6 Wind 240 deg - No Ice+1.0 Guy 43 1.2D+1.6W (pattern 1) 240 deg - No Ice+1.0 Guy
44 1.2D+1.6W (pattern 2) 240 deg - No Ice+1.0 Guy
45 1.2D+1.6W (pattern 3) 240 deg - No Ice+1.0 Guy 46 1.2D+1.6W (pattern 4) 240 deg - No Ice+1.0 Guy
47 1.2 Dead+1.6 Wind 270 deg - No Ice+1.0 Guy 48 1.2D+1.6W (pattern 1) 270 deg - No Ice+1.0 Guy
49 1.2D+1.6W (pattern 2) 270 deg - No Ice+1.0 Guy
50 1.2D+1.6W (pattern 3) 270 deg - No Ice+1.0 Guy 51 1.2D+1.6W (pattern 4) 270 deg - No Ice+1.0 Guy
52 1.2 Dead+1.6 Wind 300 deg - No Ice+1.0 Guy 53 1.2D+1.6W (pattern 1) 300 deg - No Ice+1.0 Guy
54 1.2D+1.6W (pattern 2) 300 deg - No Ice+1.0 Guy
55 1.2D+1.6W (pattern 3) 300 deg - No Ice+1.0 Guy 56 1.2D+1.6W (pattern 4) 300 deg - No Ice+1.0 Guy
57 1.2 Dead+1.6 Wind 330 deg - No Ice+1.0 Guy 58 1.2D+1.6W (pattern 1) 330 deg - No Ice+1.0 Guy
59 1.2D+1.6W (pattern 2) 330 deg - No Ice+1.0 Guy
60 1.2D+1.6W (pattern 3) 330 deg - No Ice+1.0 Guy 61 1.2D+1.6W (pattern 4) 330 deg - No Ice+1.0 Guy
62 Dead+Wind 0 deg - Service+Guy
63 Dead+Wind 30 deg - Service+Guy
64 Dead+Wind 60 deg - Service+Guy
65 Dead+Wind 90 deg - Service+Guy 66 Dead+Wind 120 deg - Service+Guy
67 Dead+Wind 150 deg - Service+Guy 68 Dead+Wind 180 deg - Service+Guy
69 Dead+Wind 210 deg - Service+Guy
70 Dead+Wind 240 deg - Service+Guy 71 Dead+Wind 270 deg - Service+Guy
72 Dead+Wind 300 deg - Service+Guy 73 Dead+Wind 330 deg - Service+Guy
Maximum Tower Deflections - Service Wind
Section
No.
Elevation
ft
Horz.
Deflection
in
Gov.
Load
Comb.
Tilt
°
Twist
°
T1 300 - 296 2.182 64 0.063 0.019
T2 296 - 292 2.206 64 0.064 0.019 T3 292 - 288 2.232 64 0.065 0.019
T4 288 - 284 2.258 64 0.069 0.019 T5 284 - 280 2.289 64 0.073 0.018
T6 280 - 276 2.322 64 0.081 0.018
T7 276 - 272 2.372 64 0.086 0.018 T8 272 - 268 2.423 64 0.086 0.018
T9 268 - 264 2.470 64 0.080 0.019 T10 264 - 260 2.512 64 0.072 0.020
T11 260 - 240 2.554 63 0.062 0.021
T12 240 - 220 2.704 62 0.027 0.026 T13 220 - 200 2.729 62 0.034 0.029
Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
23 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Section No.
Elevation
ft
Horz. Deflection
in
Gov. Load
Comb.
Tilt
°
Twist
°
T14 200 - 180 2.592 62 0.059 0.032 T15 180 - 160 2.342 62 0.063 0.035
T16 160 - 140 2.095 62 0.065 0.036 T17 140 - 120 1.795 62 0.077 0.037
T18 120 - 100 1.465 70 0.073 0.038
T19 100 - 80 1.179 70 0.054 0.038 T20 80 - 60 1.009 70 0.038 0.037
T21 60 - 40 0.861 70 0.041 0.036 T22 40 - 20 0.662 70 0.059 0.033
T23 20 - 8 0.367 70 0.079 0.029
T24 8 - 0 0.151 70 0.086 0.026
Critical Deflections and Radius of Curvature - Service Wind
Elevation
ft
Appurtenance Gov. Load
Comb.
Deflection
in
Tilt
°
Twist
°
Radius of Curvature
ft
300' Lightning Rod 5/8'' x 3' on 7' Mount Pipe
64 2.182 0.063 0.019 171580
285' BXA-70080-8CF-EDIN-2 w/ Mount
Pipe
64 2.281 0.072 0.019 70345
280' Guy 64 2.322 0.081 0.018 13211
245' (2) RV65-18-02DPL2 w/ Mount Pipe
63 2.674 0.034 0.025 27658
227' (2) 58010 w/ Mount Pipe 62 2.740 0.020 0.028 28284
180' Guy 62 2.342 0.063 0.035 49913 151' Side Lighting 62 1.967 0.070 0.037 76404
100' Guy 70 1.179 0.054 0.038 31685
Maximum Tower Deflections - Design Wind
Section
No.
Elevation
ft
Horz.
Deflection in
Gov.
Load Comb.
Tilt
°
Twist
°
T1 300 - 296 51.093 4 0.230 0.184
T2 296 - 292 50.959 3 0.225 0.184
T3 292 - 288 50.850 3 0.210 0.183 T4 288 - 284 50.752 3 0.230 0.182
T5 284 - 280 50.685 3 0.267 0.180
T6 280 - 276 50.640 3 0.321 0.177
T7 276 - 272 50.735 3 0.354 0.178
T8 272 - 268 50.831 3 0.354 0.179 T9 268 - 264 50.904 3 0.302 0.187
T10 264 - 260 50.922 3 0.233 0.195 T11 260 - 240 50.865 3 0.239 0.203
T12 240 - 220 49.796 3 0.528 0.233
T13 220 - 200 47.354 22 0.861 0.256 T14 200 - 180 43.616 42 1.098 0.272
T15 180 - 160 38.992 42 1.172 0.283 T16 160 - 140 34.529 42 1.176 0.294
T17 140 - 120 29.834 46 1.251 0.300
T18 120 - 100 25.061 46 1.187 0.301
Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
24 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Section No.
Elevation
ft
Horz. Deflection
in
Gov. Load
Comb.
Tilt
°
Twist
°
T19 100 - 80 20.643 46 1.009 0.297 T20 80 - 60 17.172 46 0.845 0.295
T21 60 - 40 13.856 46 0.845 0.288 T22 40 - 20 10.046 46 1.016 0.265
T23 20 - 8 5.370 45 1.200 0.233
T24 8 - 0 2.190 45 1.271 0.210
Critical Deflections and Radius of Curvature - Design Wind
Elevation
ft
Appurtenance Gov. Load
Comb.
Deflection
in
Tilt
°
Twist
°
Radius of Curvature
ft
300' Lightning Rod 5/8'' x 3' on 7' Mount Pipe
4 51.093 0.230 0.184 22105
285' BXA-70080-8CF-EDIN-2 w/ Mount
Pipe
3 50.702 0.256 0.181 8202
280' Guy 3 50.640 0.321 0.177 1627
245' (2) RV65-18-02DPL2 w/ Mount Pipe
3 50.194 0.461 0.226 3257
227' (2) 58010 w/ Mount Pipe 2 48.359 0.743 0.248 3310
180' Guy 42 38.992 1.172 0.283 4970 151' Side Lighting 42 32.428 1.213 0.297 8525
100' Guy 46 20.643 1.009 0.297 3731
Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
25 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Bolt Design Data
Section
No.
Elevation
ft
Component
Type
Bolt
Grade
Bolt Size
in
Number
Of Bolts
Maximum
Load per Bolt
K
Allowable
Load K
Ratio
Load
Allowable
Allowable
Ratio
Criteria
T1 300 Diagonal A325N 0.625 1 3.701 9.108 0.406
1 Member Block Shear
Top Girt A325N 0.625 1 1.421 9.108 0.156
1 Member Block Shear
T2 296 Diagonal A325N 0.625 1 4.304 9.108 0.473
1 Member Block
Shear T3 292 Diagonal A325N 0.625 1 4.725 9.108
0.519 1 Member Block
Shear T4 288 Diagonal A325N 0.625 1 6.173 9.108
0.678 1 Member Block
Shear
T5 284 Diagonal A325X 0.625 1 9.802 10.440 0.939
1 Gusset Bearing
T6 280 Leg A325N 0.875 4 10.457 40.589 0.258
1 Bolt Tension
Diagonal A325X 0.625 2 8.939 10.740 0.832
1 Member Block
Shear
Secondary Horizontal
A325N 0.500 1 0.858 6.253 0.137
1 Member Block Shear
Top Guy Pull-Off@280
A325N 0.625 2 24.253 24.673 0.983*
1 Member Block Shear
Torque Arm
Top@280
A490X 0.875 2 32.027 35.150 0.911*
1 Gusset Block
Shear Torque Arm
Bottom@280
A490X 0.875 2 29.479 34.256 0.861*
1 Gusset Bearing
T7 276 Diagonal A325X 0.625 2 7.700 10.740 0.717
1 Member Block
Shear
Secondary Horizontal
A325N 0.500 1 0.290 6.253 0.046
1 Member Block Shear
T8 272 Diagonal A325N 0.625 2 5.925 12.425 0.477
1 Bolt Shear
Secondary
Horizontal
A325N 0.500 1 1.723 6.253 0.275
1 Member Block
Shear
Bottom Guy Pull-Off@280
A325N 0.625 2 3.184 24.851 0.128
1 Bolt Shear
T9 268 Diagonal A325N 0.625 2 4.752 8.224 0.578
1 Member Block Shear
Secondary
Horizontal
A325N 0.500 1 2.963 6.253 0.474
1 Member Block
Shear T10 264 Diagonal A325N 0.625 2 5.055 12.425
0.407 1 Bolt Shear
Secondary Horizontal
A325N 0.500 1 2.238 6.253 0.358
1 Member Block Shear
Bottom Girt A325N 0.625 2 2.081 11.623 0.179
1 Member Block Shear
T11 260 Leg A325N 0.875 4 14.366 40.589 0.354
1 Bolt Tension
Diagonal A325N 0.500 1 7.451 7.952 0.937
1 Bolt Shear
T12 240 Leg A325N 0.875 4 25.895 40.589 0.638
1 Bolt Tension
Diagonal A325N 0.500 1 4.916 7.952 0.618
1 Bolt Shear
T13 220 Leg A325N 0.875 4 21.690 40.589 0.534
1 Bolt Tension
Diagonal A325X 0.500 1 9.078 9.719 0.934
1 Bolt Shear
T14 200 Leg A325N 0.875 4 8.325 40.589 0.205
1 Bolt Tension
Diagonal A325X 0.625 1 11.389 12.492 0.912
1 Member Block Shear
Secondary
Horizontal
A325N 0.500 1 2.138 6.253 0.342
1 Member Block
Shear
Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
26 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Section No.
Elevation
ft
Component Type
Bolt Grade
Bolt Size
in
Number Of
Bolts
Maximum Load per
Bolt K
Allowable Load
K
Ratio
Load
Allowable
Allowable Ratio
Criteria
T15 180 Leg A325N 0.875 4 8.169 40.589 0.201
1 Bolt Tension
Diagonal A325N 0.625 1 6.692 12.425 0.539
1 Bolt Shear
Secondary
Horizontal
A325N 0.500 1 2.137 6.253 0.342
1 Member Block
Shear Top Guy
Pull-Off@180
A325N 0.750 2 12.442 16.747 0.743
1 Gusset Bearing
T16 160 Leg A325N 0.875 4 7.863 40.589 0.194
1 Bolt Tension
Diagonal A325N 0.500 1 3.442 7.952 0.433
1 Bolt Shear
Secondary
Horizontal
A325N 0.500 1 2.188 6.253 0.350
1 Member Block
Shear T17 140 Leg A325N 0.875 4 8.021 40.589
0.198 1 Bolt Tension
Diagonal A325N 0.500 1 7.032 7.952 0.884
1 Bolt Shear
Secondary
Horizontal
A325N 0.500 1 2.233 6.253 0.357
1 Member Block
Shear T18 120 Leg A325N 0.875 4 11.903 40.589
0.293 1 Bolt Tension
Diagonal A325X 0.500 1 8.097 8.265 0.980
1 Gusset Bearing
T19 100 Leg A325N 0.875 4 17.044 40.589 0.420
1 Bolt Tension
Diagonal A325N 0.625 1 8.296 10.440 0.795
1 Gusset Bearing
Top Guy
Pull-Off@100
A325N 0.750 2 11.990 16.747 0.716
1 Gusset Bearing
T20 80 Leg A325N 0.875 4 11.383 40.589 0.280
1 Bolt Tension
Diagonal A325N 0.500 1 6.354 7.952 0.799
1 Bolt Shear
T21 60 Leg A325N 0.875 4 10.706 40.589 0.264
1 Bolt Tension
Diagonal A325N 0.500 1 4.175 7.952 0.525
1 Bolt Shear
Secondary Horizontal
A325N 0.500 1 3.039 6.253 0.486
1 Member Block Shear
T22 40 Leg A325N 0.875 4 11.685 40.589 0.288
1 Bolt Tension
Diagonal A325N 0.500 1 3.691 7.952 0.464
1 Bolt Shear
Secondary Horizontal
A325N 0.500 1 3.055 6.253 0.489
1 Member Block Shear
T23 20 Leg A325N 0.875 4 10.727 40.589 0.264
1 Bolt Tension
Diagonal A325N 0.500 1 4.423 4.690 0.943
1 Member Block
Shear
T24 8 Leg A325N 0.875 4 10.312 40.589 0.254
1 Bolt Tension
*Capacity has been adjusted based on modification.
Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
27 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Guy Design Data
Section
No.
Elevation
ft
Size
Initial
Tension K
Breaking
Load K
Actual
Tu
K
Allowable
Tn K
Required
S.F.
Actual
S.F.
T6 280' (A) (658) 1 EHS 9.405 104.500 57.754 62.700 1.000 1.086
280' (A) (659) 1 EHS 9.405 104.500 57.309 62.700 1.000 1.094
280' (B) (652) 1 EHS 9.405 104.500 57.178 62.700 1.000 1.097
280' (B) (653) 1 EHS 9.405 104.500 57.748 62.700 1.000 1.086
280' (C) (640) 1 EHS 9.405 104.500 57.327 62.700 1.000 1.094
280' (C) (641) 1 EHS 9.405 104.500 57.201 62.700 1.000 1.096
T15 180' (A) (639) 1 EHS 7.315 104.500 64.549 62.700 1.000 0.971 180' (B) (638) 1 EHS 7.315 104.500 64.580 62.700 1.000 0.971 180' (C) (634) 1 EHS 7.315 104.500 64.551 62.700 1.000 0.971
T19 100' (A) (633) 1 EHS 12.540 104.500 54.903 62.700 1.000 1.142
100' (B) (632) 1 EHS 12.540 104.500 54.913 62.700 1.000 1.142
100' (C) (628) 1 EHS 12.540 104.500 54.903 62.700 1.000 1.142
Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
28 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Compression Checks
Leg Design Data (Compression)
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
T1 300 - 296 ROHN 2.5 EH 4' 4' 51.9
K=1.00
2.254 -4.958 83.252 0.060 1
T2 296 - 292 ROHN 2.5 EH 4' 4' 51.9
K=1.00 2.254 -13.401 83.252 0.161 1
T3 292 - 288 ROHN 2.5 EH 4' 4' 51.9
K=1.00
2.254 -23.583 83.252 0.283 1
T4 288 - 284 ROHN 2.5 EH 4' 4' 51.9
K=1.00 2.254 -34.823 83.252 0.418 1
T5 284 - 280 ROHN 2.5 EH 4' 4' 51.9
K=1.00
2.254 -52.912 83.252 0.636 1
T6 280 - 276 ROHN 3 EH 4' 2' 21.1
K=1.00
3.016 -49.530 131.362 0.377 1
T7 276 - 272 ROHN 3 EH 4' 2' 21.1
K=1.00 3.016 -16.741 131.362 0.127 1
T8 272 - 268 ROHN 3 EH 4' 2' 21.1
K=1.00
3.016 -99.453 131.362 0.757 1
T9 268 - 264 ROHN 3 EH 4' 2' 21.1
K=1.00 3.016 -120.140 131.362 0.915 1
T10 264 - 260 ROHN 3 EH 4' 2' 21.1
K=1.00
3.016 -129.206 131.362 0.984 1
T11 260 - 240 BU# 812483---3 XS w/
4.5x0.5
20' 4' 47.0
K=1.00
6.151 -181.514 235.464 0.771 1
T12 240 - 220 BU# 812483---3 XS w/
4.5x0.5 20' 4' 47.0
K=1.00 6.151 -184.994 235.464 0.786 1
T13 220 - 200 BU# 812483---3 XS w/
4.5x0.5
20' 4' 47.0
K=1.00
6.151 -166.874 235.464 0.709 1
T14 200 - 180 ROHN 3 EH 20' 2' 21.1
K=1.00 3.016 -99.940 131.362 0.761 1
T15 180 - 160 ROHN 3 EH 20' 2' 21.1
K=1.00
3.016 -98.077 131.362 0.747 1
T16 160 - 140 ROHN 3 EH 20' 2' 21.1
K=1.00
3.016 -94.391 131.362 0.719 1
T17 140 - 120 ROHN 3 EH 20' 2' 21.1
K=1.00 3.016 -128.906 131.362 0.981 1
T18 120 - 100 BU# 812483---3 XS w/
4.5x0.5
20' 4' 47.0
K=1.00
6.151 -202.524 235.464 0.860 1
T19 100 - 80 BU# 812483---3 XS w/
4.5x0.5 20' 4' 47.0
K=1.00 6.151 -204.532 235.464 0.869 1
T20 80 - 60 ROHN 3.5 EH 20' 4' 36.7
K=1.00
3.678 -136.594 149.975 0.911 1
T21 60 - 40 ROHN 3.5 EH 20' 2' 18.4
K=1.00
3.678 -139.724 161.495 0.865 1
T22 40 - 20 ROHN 3.5 EH 20' 2' 18.4
K=1.00 3.678 -140.268 161.495 0.869 1
T23 20 - 8 ROHN 3.5 EH 12' 4' 36.7
K=1.00
3.678 -128.727 149.975 0.858 1
Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
29 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Section No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
T24 8 - 0 ROHN 3.5 EH 8'6-5/32'
'
4'3-3/32'
'
39.1
K=1.00
3.678 -123.821 148.029 0.836 1
1 P u / Pn controls
Diagonal Design Data (Compression)
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
T1 300 - 296 L2x2x1/4 6'5-7/32''
2'11-11/32''
97.8 K=1.08
0.938 -3.614 18.370 0.197 1
T2 296 - 292 L2x2x1/4 6'5-7/32'
'
2'11-11/
32''
97.8
K=1.08
0.938 -4.426 18.370 0.241 1
T3 292 - 288 L2x2x1/4 6'5-7/32'
'
2'11-11/
32''
97.8
K=1.08
0.938 -4.598 18.370 0.250 1
T4 288 - 284 L2x2x1/4 6'5-7/32'
' 2'11-11/
32'' 97.8
K=1.08 0.938 -6.438 18.370 0.350 1
T5 284 - 280 L2 1/2x2 1/2x1/4 6'5-7/32'
'
2'11-11/
32''
84.0
K=1.17
1.190 -9.579 31.973 0.300 1
T6 280 - 276 L2 1/2x2 1/2x1/4 6'5-7/32'
' 3'25/32'' 74.9
K=1.00 1.190 -16.669 35.529 0.469 1
T7 276 - 272 L2 1/2x2 1/2x1/4 6'5-7/32'
'
3'3/8'' 74.1
K=1.00
1.190 -16.725 35.845 0.467 1
T8 272 - 268 L2x2x1/4 6'5-7/32'
'
3'3/8'' 93.0
K=1.00
0.938 -11.851 19.267 0.615 1
T9 268 - 264 L2x2x1/4 6'5-7/32'
' 3'3/8'' 93.0
K=1.00 0.938 -8.074 19.267 0.419 1
T10 264 - 260 L2x2x1/4 6'5-7/32'
'
3'3/8'' 93.0
K=1.00
0.938 -10.109 19.267 0.525 1
T11 260 - 240 L2x2x5/16 6'5-7/32'
' 2'11'' 97.3
K=1.08 1.150 -7.451 22.631 0.329 1
T12 240 - 220 L2x2x5/16 6'5-7/32'
'
2'11'' 97.3
K=1.08
1.150 -4.916 22.631 0.217 1
T13 220 - 200 L2x2x5/16 6'5-7/32'
'
2'11'' 97.3
K=1.08
1.150 -8.411 22.631 0.372 1
T14 200 - 180 L2x2x5/16 6'5-7/32'
' 3'3/8'' 93.3
K=1.00 1.150 -13.279 23.566 0.563 1
T15 180 - 160 L2x2x5/16 6'5-7/32'
'
3'3/8'' 93.3
K=1.00
1.150 -6.692 23.566 0.284 1
T16 160 - 140 L2x2x5/16 6'5-7/32'
' 3'3/8'' 93.3
K=1.00 1.150 -3.442 23.566 0.146 1
T17 140 - 120 L2x2x5/16 6'5-7/32'
'
3'3/8'' 93.3
K=1.00
1.150 -7.032 23.566 0.298 1
T18 120 - 100 L2x2x5/16 6'5-7/32'
'
2'11'' 97.3
K=1.08
1.150 -8.790 22.631 0.388 1
T19 100 - 80 L2x2x5/16 6'5-7/32'
' 2'10-3/4'
' 96.8
K=1.09 1.150 -9.016 22.743 0.396 1
T20 80 - 60 L2x2x5/16 6'5-7/32'
'
2'10-11/
16''
96.7
K=1.09
1.150 -6.354 22.774 0.279 1
T21 60 - 40 L1 1/2x1 1/2x3/16 6'5-7/32' 3'1/16'' 122.9 0.527 -4.175 7.712 0.541 1
Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
30 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Section No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
' K=1.00
T22 40 - 20 L1 1/2x1 1/2x3/16 6'5-7/32'
'
3'1/16'' 122.9
K=1.00
0.527 -3.691 7.712 0.479 1
T23 20 - 8 L1 1/2x1 1/2x3/16 6'5-7/32'
' 2'10-13/
16'' 119.0
K=1.00 0.527 -5.100 8.107 0.629 1
1 P u / Pn controls
Secondary Horizontal Design Data (Compression)
Section No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
T6 280 - 276 L1 1/2x1 1/2x1/4 5'1/2'' 4'9'' 97.6
K=0.50
0.688 -0.858 13.491 0.064 1
T7 276 - 272 L1 1/2x1 1/2x1/4 5'1/2'' 4'9'' 97.6
K=0.50
0.688 -0.303 13.491 0.022 1
T8 272 - 268 L1 1/2x1 1/2x1/4 5'1/2'' 4'9'' 97.6
K=0.50 0.688 -1.723 13.491 0.128 1
T9 268 - 264 L1 1/2x1 1/2x1/4 5'1/2'' 4'9'' 97.6
K=0.50
0.688 -2.081 13.491 0.154 1
T10 264 - 260 L1 1/2x1 1/2x1/4 5'1/2'' 4'9'' 97.6
K=0.50
0.688 -2.238 13.491 0.166 1
T14 200 - 180 L1 1/2x1 1/2x1/4 5'1/2'' 4'9'' 97.6
K=0.50
0.688 -1.731 13.491 0.128 1
T15 180 - 160 L1 1/2x1 1/2x1/4 5'1/2'' 4'9'' 97.6
K=0.50
0.688 -1.699 13.491 0.126 1
T16 160 - 140 L1 1/2x1 1/2x1/4 5'1/2'' 4'9'' 97.6
K=0.50 0.688 -1.635 13.491 0.121 1
T17 140 - 120 L1 1/2x1 1/2x1/4 5'1/2'' 4'9'' 97.6
K=0.50
0.688 -2.233 13.491 0.166 1
T21 60 - 40 L1 1/2x1 1/2x1/4 5'1/2'' 4'8-1/2'' 96.7
K=0.50 0.688 -2.420 13.609 0.178 1
T22 40 - 20 L1 1/2x1 1/2x1/4 5'1/2'' 4'8-1/2'' 96.7
K=0.50
0.688 -2.430 13.609 0.179 1
1 P u / Pn controls
Top Girt Design Data (Compression)
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
T1 300 - 296 L2x2x1/4 5'1/2'' 4'6-3/4'' 140.0
K=1.00
0.938 -1.502 10.808 0.139 1
1 P u / Pn controls
Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
31 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Bottom Girt Design Data (Compression)
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
T10 264 - 260 L4x2x1/4 5'1/2'' 4'9'' 131.8 K=1.00
1.438 -0.572 18.596 0.031 1
1 P u / Pn controls
Top Guy Pull-Off Design Data (Compression)
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
T6 280 - 276 2L2x2x3/8x3/8 5'1/2'' 4'9-5/8'' 97.0
K=1.00
2.720 -36.065 53.696 0.672 1
2L 'a' > 28.303 in - 644
1 P u / Pn controls
Top Guy Pull-Off Bending Design Data
Section
No.
Elevation
ft
Size
Mux
kip-ft
Mnx
kip-ft
Ratio
Mux
Mnx
Muy
kip-ft
Mny
kip-ft
Ratio
Muy
Mny
T6 280 - 276 2L2x2x3/8x3/8 0.000 2.843 0.000 0.000 5.185 0.000
Top Guy Pull-Off Interaction Design Data
Section No.
Elevation
ft
Size
Ratio
Pu
Pn
Ratio
Mux
Mnx
Ratio
Muy
Mny
Comb. Stress
Ratio
Allow. Stress
Ratio
Criteria
T6 280 - 276 2L2x2x3/8x3/8 0.672 0.000 0.000 0.672 1
1.000 4.9-3
1 P u / Pn controls
Bottom Guy Pull-Off Design Data (Compression)
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
T8 272 - 268 2L2x2x3/8x3/8 5'1/2'' 4'9'' 96.0 2.720 -6.367 54.273 0.117 1
Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
32 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Section No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
K=1.00
2L 'a' > 27.996 in - 650
1 P u / Pn controls
Bottom Guy Pull-Off Bending Design Data
Section No.
Elevation
ft
Size
Mux
kip-ft
Mnx
kip-ft
Ratio
Mux
Mnx
Muy
kip-ft
Mny
kip-ft
Ratio
Muy
Mny
T8 272 - 268 2L2x2x3/8x3/8 0.000 2.843 0.000 0.000 5.185 0.000
Bottom Guy Pull-Off Interaction Design Data
Section
No.
Elevation
ft
Size
Ratio
Pu
Pn
Ratio
Mux
Mnx
Ratio
Muy
Mny
Comb.
Stress
Ratio
Allow.
Stress
Ratio
Criteria
T8 272 - 268 2L2x2x3/8x3/8 0.117 0.000 0.000 0.117 1
1.000 4.9-4
1 P u / Pn controls
Torque-Arm Bottom Design Data
Section No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
T6 280 - 276 (647) ROHN 3 STD 11'5-5/1
6''
11'2-27/
32''
69.5
K=0.60
2.228 -58.583 70.416 0.832 1
T6 280 - 276 (648) ROHN 3 STD 11'5-5/1
6''
11'2-27/
32''
69.5
K=0.60
2.228 -58.166 70.416 0.826 1
T6 280 - 276 (656) ROHN 3 STD 11'5-5/1
6''
11'2-27/
32''
69.5
K=0.60
2.228 -58.539 70.416 0.831 1
T6 280 - 276 (657) ROHN 3 STD 11'5-5/1
6''
11'2-27/
32''
69.5
K=0.60
2.228 -58.051 70.416 0.824 1
T6 280 - 276 (662) ROHN 3 STD 11'5-5/1
6'' 11'2-27/
32'' 69.5
K=0.60 2.228 -58.951 70.416 0.837 1
T6 280 - 276 (663) ROHN 3 STD 11'5-5/1
6''
11'2-27/
32''
69.5
K=0.60
2.228 -58.958 70.416 0.837 1
1 P u / Pn controls
Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
33 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Tension Checks
Leg Design Data (Tension)
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
T1 300 - 296 ROHN 2.5 EH 4' 4' 51.9 2.254 3.639 101.409 0.036 1
T2 296 - 292 ROHN 2.5 EH 4' 4' 51.9 2.254 11.477 101.409 0.113 1
T3 292 - 288 ROHN 2.5 EH 4' 4' 51.9 2.254 20.904 101.409 0.206 1
T4 288 - 284 ROHN 2.5 EH 4' 4' 51.9 2.254 31.409 101.409 0.310 1
T5 284 - 280 ROHN 2.5 EH 4' 4' 51.9 2.254 47.570 101.409 0.469 1
T6 280 - 276 ROHN 3 EH 4' 2' 21.1 3.016 41.828 135.717 0.308 1
T7 276 - 272 ROHN 3 EH 4' 2' 21.1 3.016 10.567 135.717 0.078 1
T8 272 - 268 ROHN 3 EH 4' 2' 21.1 3.016 7.101 135.717 0.052 1
T9 268 - 264 ROHN 3 EH 4' 2' 21.1 3.016 23.602 135.717 0.174 1
T10 264 - 260 ROHN 3 EH 4' 2' 21.1 3.016 43.196 135.717 0.318 1
T11 260 - 240 BU# 812483---3 XS w/
4.5x0.5
20' 4' 47.0 6.151 99.829 276.791 0.361 1
T12 240 - 220 BU# 812483---3 XS w/
4.5x0.5 20' 4' 47.0 6.151 106.740 276.791 0.386 1
T13 220 - 200 BU# 812483---3 XS w/
4.5x0.5
20' 4' 47.0 6.151 86.760 276.791 0.313 1
T14 200 - 180 ROHN 3 EH 20' 2' 21.1 3.016 16.598 135.717 0.122 1
T18 120 - 100 BU# 812483---3 XS w/
4.5x0.5
20' 4' 47.0 6.151 31.798 276.791 0.115 1
T19 100 - 80 BU# 812483---3 XS w/
4.5x0.5
20' 4' 47.0 6.151 9.809 276.791 0.035 1
1 P u / Pn controls
Diagonal Design Data (Tension)
Section No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
T1 300 - 296 L2x2x1/4 6'5-7/32'
'
2'11-11/
32''
60.4 0.563 3.701 24.485 0.151 1
T2 296 - 292 L2x2x1/4 6'5-7/32' 2'11-11/ 60.4 0.563 4.304 24.485 0.176 1
Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
34 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Section No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
' 32''
T3 292 - 288 L2x2x1/4 6'5-7/32'
'
2'11-11/
32''
60.4 0.563 4.725 24.485 0.193 1
T4 288 - 284 L2x2x1/4 6'5-7/32'
' 2'11-11/
32'' 60.4 0.563 6.173 24.485 0.252 1
T5 284 - 280 L2 1/2x2 1/2x1/4 6'5-7/32'
'
2'11-11/
32''
47.8 0.752 9.802 36.654 0.267 1
T6 280 - 276 L2 1/2x2 1/2x1/4 6'5-7/32'
'
3'25/32'' 47.8 0.752 17.878 36.654 0.488 1
T7 276 - 272 L2 1/2x2 1/2x1/4 6'5-7/32'
' 3'3/8'' 47.3 0.752 15.400 36.654 0.420 1
T8 272 - 268 L2x2x1/4 6'5-7/32'
'
3'3/8'' 59.7 0.563 7.441 24.485 0.304 1
T9 268 - 264 L2x2x1/4 6'5-7/32'
' 3'3/8'' 59.7 0.563 9.504 24.485 0.388 1
T10 264 - 260 L2x2x1/4 6'5-7/32'
'
3'3/8'' 59.7 0.563 6.169 24.485 0.252 1
T11 260 - 240 L2x2x5/16 6'5-7/32'
'
2'11'' 60.5 0.716 6.558 31.147 0.211 1
T12 240 - 220 L2x2x5/16 6'5-7/32'
' 2'11'' 60.5 0.716 4.737 31.147 0.152 1
T13 220 - 200 L2x2x5/16 6'5-7/32'
'
2'11'' 60.5 0.716 9.078 31.147 0.291 1
T14 200 - 180 L2x2x5/16 6'5-7/32'
'
3'3/8'' 60.5 0.687 11.389 29.872 0.381 1
T15 180 - 160 L2x2x5/16 6'5-7/32'
'
3'3/8'' 60.5 0.687 3.833 29.872 0.128 1
T16 160 - 140 L2x2x5/16 6'5-7/32'
'
3'3/8'' 60.5 0.716 1.517 31.147 0.049 1
T17 140 - 120 L2x2x5/16 6'5-7/32'
' 3'3/8'' 60.5 0.716 4.277 31.147 0.137 1
T18 120 - 100 L2x2x5/16 6'5-7/32'
'
2'11'' 60.5 0.716 8.097 31.147 0.260 1
T19 100 - 80 L2x2x5/16 6'5-7/32'
'
2'10-3/4'
'
60.5 0.687 8.296 29.872 0.278 1
T20 80 - 60 L2x2x5/16 6'5-7/32'
' 2'10-11/
16'' 60.0 0.716 5.751 31.147 0.185 1
T21 60 - 40 L1 1/2x1 1/2x3/16 6'5-7/32'
'
3'1/16'' 79.0 0.308 2.093 13.381 0.156 1
T22 40 - 20 L1 1/2x1 1/2x3/16 6'5-7/32'
' 3'1/16'' 79.0 0.308 1.875 13.381 0.140 1
T23 20 - 8 L1 1/2x1 1/2x3/16 6'5-7/32'
'
2'10-13/
16''
79.0 0.308 4.423 13.381 0.331 1
1 P u / Pn controls
Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
35 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Horizontal Design Data (Tension)
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
T24 8 - 0 C25.5x2x3/16 2'6-1/4'' 2'2-1/4'' 86.7 5.461 0.101 176.934 0.001 1
1 P u / Pn controls
Secondary Horizontal Design Data (Tension)
Section No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
T6 280 - 276 L1 1/2x1 1/2x1/4 5'1/2'' 4'9'' 127.0 0.398 0.858 17.332 0.049 1
T7 276 - 272 L1 1/2x1 1/2x1/4 5'1/2'' 4'9'' 127.0 0.398 0.290 17.332 0.017 1
T8 272 - 268 L1 1/2x1 1/2x1/4 5'1/2'' 4'9'' 127.0 0.398 1.723 17.332 0.099 1
T9 268 - 264 L1 1/2x1 1/2x1/4 5'1/2'' 4'9'' 127.0 0.398 2.963 17.332 0.171 1
T10 264 - 260 L1 1/2x1 1/2x1/4 5'1/2'' 4'9'' 127.0 0.398 2.238 17.332 0.129 1
T14 200 - 180 L1 1/2x1 1/2x1/4 5'1/2'' 4'9'' 127.0 0.398 2.138 17.332 0.123 1
T15 180 - 160 L1 1/2x1 1/2x1/4 5'1/2'' 4'9'' 127.0 0.398 2.137 17.332 0.123 1
T16 160 - 140 L1 1/2x1 1/2x1/4 5'1/2'' 4'9'' 127.0 0.398 2.188 17.332 0.126 1
T17 140 - 120 L1 1/2x1 1/2x1/4 5'1/2'' 4'9'' 127.0 0.398 2.233 17.332 0.129 1
T21 60 - 40 L1 1/2x1 1/2x1/4 5'1/2'' 4'8-1/2'' 125.9 0.398 3.039 17.332 0.175 1
T22 40 - 20 L1 1/2x1 1/2x1/4 5'1/2'' 4'8-1/2'' 125.9 0.398 3.055 17.332 0.176 1
1 P u / Pn controls
Top Girt Design Data (Tension)
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
T1 300 - 296 L2x2x1/4 5'1/2'' 4'6-3/4'' 94.6 0.563 1.421 24.485 0.058 1
T24 8 - 0 C32.75x2x3/16 5'1/2'' 4'8-1/2'' 205.8 6.820 25.896 220.978 0.117 1
1 P u / Pn controls
Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
36 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Bottom Girt Design Data (Tension)
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
T10 264 - 260 L4x2x1/4 5'1/2'' 4'9'' 105.3 0.938 4.162 40.781 0.102 1
1 P u / Pn controls
Top Guy Pull-Off Design Data (Tension)
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
T6 280 - 276 2L2x2x3/8x3/8 5'1/2'' 4'9-5/8'' 97.0 1.618 48.506 70.388 0.689 1
2L 'a' > 28.303 in - 644 T15 180 - 160 2L3x2x1/4x3/8 5'1/2'' 4'9'' 64.0 1.457 24.883 63.374 0.393 1
2L 'a' > 20.871 in - 636 T19 100 - 80 2L3x2x1/4x3/8 5'1/2'' 4'9'' 64.0 1.457 23.979 63.374 0.378 1
2L 'a' > 20.871 in - 630
1 P u / Pn controls
Top Guy Pull-Off Bending Design Data
Section No.
Elevation
ft
Size
Mux
kip-ft
Mnx
kip-ft
Ratio
Mux
Mnx
Muy
kip-ft
Mny
kip-ft
Ratio
Muy
Mny
T6 280 - 276 2L2x2x3/8x3/8 0.000 2.843 0.000 0.000 5.185 0.000
T15 180 - 160 2L3x2x1/4x3/8 0.000 4.374 0.000 0.000 3.488 0.000
T19 100 - 80 2L3x2x1/4x3/8 0.000 4.374 0.000 0.000 3.488 0.000
Top Guy Pull-Off Interaction Design Data
Section No.
Elevation
ft
Size
Ratio
Pu
Pn
Ratio
Mux
Mnx
Ratio
Muy
Mny
Comb. Stress
Ratio
Allow. Stress
Ratio
Criteria
T6 280 - 276 2L2x2x3/8x3/8 0.689 0.000 0.000 0.689 1
1.000 4.9-3
T15 180 - 160 2L3x2x1/4x3/8 0.393 0.000 0.000 0.393 1
1.000 4.9-3
T19 100 - 80 2L3x2x1/4x3/8 0.378 0.000 0.000 0.378 1
1.000 4.9-3
1 P u / Pn controls
Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
37 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Torque-Arm Top Design Data
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
T6 280 - 276 (642) L3 1/2x3 1/2x1/2 8'2-5/32''
8'23/32'' 91.3 2.063 63.770 100.547 0.634 1
T6 280 - 276 (643) L3 1/2x3 1/2x1/2 8'2-5/32'
'
8'23/32'' 91.3 2.063 63.798 100.547 0.635 1
T6 280 - 276 (654) L3 1/2x3 1/2x1/2 8'2-5/32'
'
8'23/32'' 91.3 2.063 63.650 100.547 0.633 1
T6 280 - 276 (655) L3 1/2x3 1/2x1/2 8'2-5/32'
' 8'23/32'' 91.3 2.063 63.682 100.547 0.633 1
T6 280 - 276 (660) L3 1/2x3 1/2x1/2 8'2-5/32'
'
8'23/32'' 91.3 2.063 64.053 100.547 0.637 1
T6 280 - 276 (661) L3 1/2x3 1/2x1/2 8'2-5/32'
' 8'23/32'' 91.3 2.063 64.049 100.547 0.637 1
1 P u / Pn controls
*Modified section
Section Capacity Table
Section
No.
Elevation
ft
Component
Type
Size Critical
Element
P
K
øPallow
K
%
Capacity
Pass
Fail
T1 300 - 296 Leg ROHN 2.5 EH 3 -4.958 83.252 6.0 Pass T2 296 - 292 Leg ROHN 2.5 EH 15 -13.401 83.252 16.1 Pass
T3 292 - 288 Leg ROHN 2.5 EH 23 -23.583 83.252 28.3 Pass
T4 288 - 284 Leg ROHN 2.5 EH 33 -34.823 83.252 41.8 Pass T5 284 - 280 Leg ROHN 2.5 EH 42 -52.912 83.252 63.6 Pass
T6 280 - 276 Leg ROHN 3 EH 51 -49.530 131.362 37.7 Pass T7 276 - 272 Leg ROHN 3 EH 63 -16.741 131.362 12.7 Pass
T8 272 - 268 Leg ROHN 3 EH 74 -99.453 131.362 75.7 Pass
T9 268 - 264 Leg ROHN 3 EH 86 -120.140 131.362 91.5 Pass T10 264 - 260 Leg ROHN 3 EH 98 -129.206 131.362 98.4 Pass
T11 260 - 240 Leg BU# 812483---3 XS w/ 4.5x0.5 113 -181.514 235.464 77.1 Pass T12 240 - 220 Leg BU# 812483---3 XS w/ 4.5x0.5 146 -184.994 235.464 78.6 Pass
T13 220 - 200 Leg BU# 812483---3 XS w/ 4.5x0.5 179 -166.874 235.464 70.9 Pass
T14 200 - 180 Leg ROHN 3 EH 212 -99.940 131.362 76.1 Pass T15 180 - 160 Leg ROHN 3 EH 261 -98.077 131.362 74.7 Pass
T16 160 - 140 Leg ROHN 3 EH 307 -94.391 131.362 71.9 Pass T17 140 - 120 Leg ROHN 3 EH 357 -128.906 131.362 98.1 Pass
T18 120 - 100 Leg BU# 812483---3 XS w/ 4.5x0.5 405 -202.524 235.464 86.0 Pass
T19 100 - 80 Leg BU# 812483---3 XS w/ 4.5x0.5 438 -204.532 235.464 86.9 Pass T20 80 - 60 Leg ROHN 3.5 EH 471 -136.594 149.975 91.1 Pass
T21 60 - 40 Leg ROHN 3.5 EH 504 -139.724 161.495 86.5 Pass T22 40 - 20 Leg ROHN 3.5 EH 552 -140.268 161.495 86.9 Pass
T23 20 - 8 Leg ROHN 3.5 EH 599 -128.727 149.975 85.8 Pass
T24 8 - 0 Leg ROHN 3.5 EH 619 -123.821 148.029 83.6 Pass T1 300 - 296 Diagonal L2x2x1/4 10 -3.614 18.370 19.7
40.6 (b)
Pass
T2 296 - 292 Diagonal L2x2x1/4 18 -4.426 18.370 24.1
47.3 (b)
Pass
T3 292 - 288 Diagonal L2x2x1/4 27 -4.598 18.370 25.0 51.9 (b)
Pass
T4 288 - 284 Diagonal L2x2x1/4 37 -6.438 18.370 35.0 Pass
Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
38 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Section
No.
Elevation ft
Component Type
Size Critical Element
P K
øPallow
K %
Capacity Pass Fail
67.8 (b)
T5 284 - 280 Diagonal L2 1/2x2 1/2x1/4 46 -9.579 31.973 30.0 93.9 (b)
Pass
T6 280 - 276 Diagonal L2 1/2x2 1/2x1/4 55 17.878 36.654 48.8
83.2 (b)
Pass
T7 276 - 272 Diagonal L2 1/2x2 1/2x1/4 66 -16.725 35.845 46.7
71.7 (b)
Pass
T8 272 - 268 Diagonal L2x2x1/4 78 -11.851 19.267 61.5 Pass
T9 268 - 264 Diagonal L2x2x1/4 91 -8.074 19.267 41.9
57.8 (b)
Pass
T10 264 - 260 Diagonal L2x2x1/4 105 -10.109 19.267 52.5 Pass
T11 260 - 240 Diagonal L2x2x5/16 142 -7.451 22.631 32.9 93.7 (b)
Pass
T12 240 - 220 Diagonal L2x2x5/16 148 -4.916 22.631 21.7
61.8 (b)
Pass
T13 220 - 200 Diagonal L2x2x5/16 181 -8.411 22.631 37.2
93.4 (b)
Pass
T14 200 - 180 Diagonal L2x2x5/16 214 -13.279 23.566 56.3
91.2 (b)
Pass
T15 180 - 160 Diagonal L2x2x5/16 301 -6.692 23.566 28.4 53.9 (b)
Pass
T16 160 - 140 Diagonal L2x2x5/16 311 -3.442 23.566 14.6 43.3 (b)
Pass
T17 140 - 120 Diagonal L2x2x5/16 358 -7.032 23.566 29.8
88.4 (b)
Pass
T18 120 - 100 Diagonal L2x2x5/16 408 -8.790 22.631 38.8
98.0 (b)
Pass
T19 100 - 80 Diagonal L2x2x5/16 468 -9.016 22.743 39.6
79.5 (b)
Pass
T20 80 - 60 Diagonal L2x2x5/16 501 -6.354 22.774 27.9 79.9 (b)
Pass
T21 60 - 40 Diagonal L1 1/2x1 1/2x3/16 541 -4.175 7.712 54.1 Pass T22 40 - 20 Diagonal L1 1/2x1 1/2x3/16 555 -3.691 7.712 47.9 Pass
T23 20 - 8 Diagonal L1 1/2x1 1/2x3/16 603 -5.100 8.107 62.9
94.3 (b)
Pass
T24 8 - 0 Horizontal C25.5x2x3/16 626 0.100 176.934 8.2 Pass
T6 280 - 276 Secondary Horizontal L1 1/2x1 1/2x1/4 59 -0.858 13.491 6.4 13.7 (b)
Pass
T7 276 - 272 Secondary Horizontal L1 1/2x1 1/2x1/4 72 -0.303 13.491 2.2
4.6 (b)
Pass
T8 272 - 268 Secondary Horizontal L1 1/2x1 1/2x1/4 82 -1.723 13.491 12.8
27.5 (b)
Pass
T9 268 - 264 Secondary Horizontal L1 1/2x1 1/2x1/4 95 2.963 17.332 17.1
47.4 (b)
Pass
T10 264 - 260 Secondary Horizontal L1 1/2x1 1/2x1/4 110 -2.238 13.491 16.6 35.8 (b)
Pass
T14 200 - 180 Secondary Horizontal L1 1/2x1 1/2x1/4 221 -1.731 13.491 12.8 34.2 (b)
Pass
T15 180 - 160 Secondary Horizontal L1 1/2x1 1/2x1/4 269 -1.699 13.491 12.6
34.2 (b)
Pass
T16 160 - 140 Secondary Horizontal L1 1/2x1 1/2x1/4 353 2.188 17.332 12.6
35.0 (b)
Pass
T17 140 - 120 Secondary Horizontal L1 1/2x1 1/2x1/4 365 -2.233 13.491 16.6
35.7 (b)
Pass
T21 60 - 40 Secondary Horizontal L1 1/2x1 1/2x1/4 513 -2.420 13.609 17.8 48.6 (b)
Pass
T22 40 - 20 Secondary Horizontal L1 1/2x1 1/2x1/4 560 -2.430 13.609 17.9 48.9 (b)
Pass
T1 300 - 296 Top Girt L2x2x1/4 4 -1.502 10.808 13.9
15.6 (b)
Pass
T24 8 - 0 Top Girt C32.75x2x3/16 622 25.896 220.978 11.7 Pass
Reviewed For Code Compliance
ttnnxxTToowweerr Job
82913.005.01 - LOCKWOOD 478-011, NC (BU# 812483)
Page
39 of 39
B+T Group
1717 South Boulder Ave., Suite 300
Project
Date
16:05:18 12/30/15
Tulsa, OK 74119
Phone: (918) 587-4630 FAX: (918) 295-0265
Client
Crown Castle Designed by
jzhang
Section
No.
Elevation ft
Component Type
Size Critical Element
P K
øPallow
K %
Capacity Pass Fail
T10 264 - 260 Bottom Girt L4x2x1/4 101 4.162 40.781 10.2
17.9 (b)
Pass
T6 280 - 276 Guy A@280 1 658 57.754 62.700 92.1 Pass
T15 180 - 160 Guy A@180 1 639 64.549 62.700 102.9 Fail
T19 100 - 80 Guy A@100 1 633 54.903 62.700 87.6 Pass T6 280 - 276 Guy B@280 1 653 57.748 62.700 92.1 Pass
T15 180 - 160 Guy B@180 1 638 64.580 62.700 103.0 Fail T19 100 - 80 Guy B@100 1 632 54.913 62.700 87.6 Pass
T6 280 - 276 Guy C@280 1 640 57.327 62.700 91.4 Pass
T15 180 - 160 Guy C@180 1 634 64.551 62.700 103.0 Fail T19 100 - 80 Guy C@100 1 628 54.903 62.700 87.6 Pass
T6 280 - 276 Top Guy
Pull-Off@280
2L2x2x3/8x3/8 644 48.506 70.388 68.9
98.3 (b)
Pass
T15 180 - 160 Top Guy
Pull-Off@180
2L3x2x1/4x3/8 636 24.883 63.374 39.3
74.3 (b)
Pass
T19 100 - 80 Top Guy
Pull-Off@100
2L3x2x1/4x3/8 630 23.979 63.374 37.8
71.6 (b)
Pass
T8 272 - 268 Bottom Guy Pull-Off@280
2L2x2x3/8x3/8 650 -6.367 54.273 11.7 12.8 (b)
Pass
T6 280 - 276 Torque Arm Top@280
L3 1/2x3 1/2x1/2 660 64.053 100.547 63.7 91.1 (b)
Pass
T6 280 - 276 Torque Arm
Bottom@280
ROHN 3 STD 663 -58.958 70.416 83.7 Pass
Summary
Leg (T10) 98.4 Pass Diagonal
(T18)
98.0 Pass
Horizontal
(T24)
8.2 Pass
Secondary Horizontal
(T22)
48.9 Pass
Top Girt (T1)
15.6 Pass
Bottom Girt (T10)
17.9 Pass
Guy A (T15) 102.9 Fail
Guy B (T15) 103.0 Fail Guy C (T15) 103.0 Fail
Top Guy
Pull-Off (T6)
98.3 Pass
Bottom Guy Pull-Off
(T8)
12.8 Pass
Torque Arm
Top (T6)
91.1 Pass
Torque Arm Bottom (T6)
83.7 Pass
Bolt Checks 103.0 Fail
RATING = 103.0 Fail
Reviewed For Code Compliance
APPENDIX B
BASE LEVEL DRAWING
Reviewed For Code Compliance
Reviewed For Code Compliance
APPENDIX C
ADDITIONAL CALCULATIONS
Reviewed For Code Compliance
812483 - Lockwood 478-011, NC
Base Foundation Analysis
Design Loads: Reduction FactorsCompression = k Shear =Shear = k =
Overturning =Slide =
Pad / Properties:= ft= ft
Pad Width = ftExt. Above Grade = ftReinforcement Bar Size =Number of Bars =
Pier / Properties:= ft
Reinforcement Bar Size =Number of Bars =Pier Tie Size =Tie Quantity =
Material Properties:Concrete Density = kcfConcrete Strength = psiClear Cover = inBar Tensile Strength = psi
Soil Data:Neglected Depth = ftUltimate Bearing = ksfSoil Unit Weight = kcfCohesion = ksfFriction Angle = degPassive Pressure = pcfBase Friction =
The pad steel reinforcement has not been analyzed as a part of this analysis.
Condisered pad side resistance while checking punching shear
OverturningBearingShearRebar
PROJECT
SUBJECT
DATE 12/30/15
Guyed Tower Pad & Pier Base Analysis Rev G
327.00 0.758.00 Bearing 0.60
0.500.75
Depth to BOC 3.4013.750.30
Pad Thickness 1.75
88
Pier Diameter 2.008
1044
0.153000.00
3.0060000
1.003.710.120.500.000.000.30
Summary of Results1.7%
95.3%101.6%
PASS
1717 S. Boulder, Suite 300 Tulsa, OK 74119 (918) 587-4630
Reviewed For Code Compliance
CCI Foundation Tool Suite - Guyed Drilled Pier Anchor
Page 1 of 1
CCIFTS 1.2.108.14286 - Phase 1-2 Date: 12/30/2015
BU: 812483Site Name: LOCKWOOD 478-011, NCApp Number: 318548 Revision # 0Work Order:
Guyed Drilled Pier Anchor
InputCriteria
TIA Revision: GACI 318 Revision: 2008Seismic Category: C
ForcesUplift 151 kipsShear 171 kipsMoment 85.5 k-ftSwelling Force 0 kips
Foundation DimensionsPier Diameter: 7 ftExt. above grade: 0.9 ftDepth below grade: 45 ft
Material PropertiesNumber of Rebar: 36Rebar Size: 8Tie Size 5Rebar tensile strength: 60 ksiConcrete Strength: 3000 psiUltimate Concrete Strain 0.003 in/inClear Cover to Ties: 4 in
Soil Profile: Soil
LayerThickness
(ft)From(ft)
To(ft)
Unit Weight(pcf)
Cohesion(psf)
Friction Angle(deg)
Ultimate Uplift Skin
Friction(ksf)
Ultimate Comp. Skin
Friction(ksf)
Ultimate Bearing Capacity
(ksf)SPT 'N' Counts
1 3.5 0 3.5 43 0 0 0 0 02 1.5 3.5 5 43 28 0 0 03 1 5 6 43 28 0.24 0.24 04 9 6 15 38 250 0.24 0.24 05 8.5 15 23.5 38 250 0.22 0.22 06 5 23.5 28.5 43 28 0.22 0.22 07 10 28.5 38.5 48 29 0.43 0.43 08 6.5 38.5 45 53 30 0.66 0.66 0
Analysis ResultsConcrete/Steel Check
Soil Lateral Capacity Mu (from soil analysis) 3248.43 k-ftDepth to Zero Shear: 26.0 ft φMn 4059.05 k-ftMax Moment, Mu: 3248.4 k-ft RATING: 80.0%Soil Safety Factor: 2.4Safety Factor Req'd: 1.33
RATING: 54.3%rho provided (%) 0.51
Soil Axial Capacity rho required (%) 0.33 OKConcrete Weight: 139.3 kipsSkin Friction: 230.2 kips Rebar Spacing 5.4Soil Cone: kips Spacing required 16.0 OKUplift Capacity (k), φTn: 369.5 kipsUplift (k), Tu: 151.0 kips
RATING: 40.9% Dev. Length required 18.6Dev. Length provided 43.8 OK
Overall Foundation Rating: 80.0%
(36) - #8
#5 Tie Size
45.9
'
45'
0.9'
7'
4" C.C.
Reviewed For Code Compliance
APPENDIX D
TOWER MODIFICATION DRAWINGS
Reviewed For Code Compliance
Reviewed For Code Compliance
1. Must meet TIA 2222. Need sealed 3rd partyinspection report for the cell towerupgrade at the final inspection.3. Field verify.ART 7.22.2016
Reviewed For Code Compliance
Reviewed For Code Compliance
Reviewed For Code Compliance
Reviewed For Code Compliance
Reviewed For Code Compliance
Reviewed For Code Compliance
Reviewed For Code Compliance