Structural Analysis for High Performance Services LLC 298.0’ Self-Support Tower (298.0’ AGL) Site Name: ATA-Sea Trail (478-122) Site ID: 110028-A Site FA: 13087756 Site Address: 736 Seaside Road SW, Sunset Beach, NC 28468 FDH Velocitel Engineering, PLLC Project Number 17PVVN1400 Analysis Results Tower Components 102.4% Sufficient Foundation 67.6% Sufficient Prepared By: Reviewed By: Anne Vago, EI Project Engineer I Douglas B. McLain Jr., PE Director of Engineering Investigative Services NC License No. 038662 FDH Velocitel Engineering, PLLC P-1390 FDH Velocitel Engineering, PLLC 6521 Meridien Drive Raleigh, NC, 27616 (919) 755-1012 February 09, 2017 Prepared pursuant to the ANSI/TIA-222-G Structural Standard for Antenna Supporting Structures and Antennas and 2012 North Carolina State Building Code (NCSBC) STR-RPT-10100 RG-1.3.8 02/09/2017 Reviewed For Code Compliance Reviewed For Code Compliance

Upload: others

Post on 07-Feb-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

  • Structural Analysis for

    High Performance Services LLC

    298.0’ Self-Support Tower (298.0’ AGL)

    Site Name: ATA-Sea Trail (478-122) Site ID: 110028-A Site FA: 13087756

    Site Address: 736 Seaside Road SW, Sunset Beach, NC 28468

    FDH Velocitel Engineering, PLLC Project Number 17PVVN1400

    Analysis Results Tower Components 102.4% Sufficient

    Foundation 67.6% Sufficient

    Prepared By: Reviewed By:

    Anne Vago, EI

    Project Engineer I Douglas B. McLain Jr., PE

    Director of Engineering Investigative Services NC License No. 038662

    FDH Velocitel Engineering, PLLC P-1390

    FDH Velocitel Engineering, PLLC

    6521 Meridien Drive Raleigh, NC, 27616

    (919) 755-1012

    February 09, 2017

    Prepared pursuant to the ANSI/TIA-222-G Structural Standard for Antenna Supporting Structures and Antennas and 2012 North Carolina State Building Code (NCSBC)

    STR-RPT-10100 RG-1.3.8

    02/09/2017

    Reviewed For Code Compliance

    Reviewed For Code Compliance

  • Structural Analysis Report High Performance Services LLC

    Site ID: 110028-A February 09, 2017

    TABLE OF CONTENTS

    EXECUTIVE SUMMARY .......................................................................................................................................................... 3 Conclusions ............................................................................................................................................................... 3 Recommendations .................................................................................................................................................... 3

    APPURTENANCE LISTING ..................................................................................................................................................... 4 RESULTS ................................................................................................................................................................................. 5 GENERAL COMMENTS ........................................................................................................................................................... 7 LIMITATIONS ........................................................................................................................................................................... 7 APPENDIX ................................................................................................................................................................................ 8

    STR-RPT-10100 2

    Reviewed For Code Compliance

  • Structural Analysis Report High Performance Services LLC

    Site ID: 110028-A February 09, 2017

    EXECUTIVE SUMMARY At the request of High Performance Services LLC, FDH Velocitel Engineering, PLLC performed a structural analysis of the existing Self-Support Tower located in Sunset Beach, NC to determine whether the tower is structurally adequate to support the antenna configuration in place per Table 1 pursuant to the ANSI/TIA-222-G Structural Standard for Antenna Supporting Structures and Antennas and 2012 North Carolina State Building Code (NCSBC). Information pertaining to the antenna loading, current tower geometry, member sizes, and below grade parameters was obtained from:

    Source Document Type Reference Date World Tower Company, Inc. Tower & Foundation Drawings Drawing No. Q09995 December 09, 2009

    Tower Engineering Professionals, Inc. Geotechnical Report Project No. 092441.11 November 17, 2009 FDH Engineering, Inc. Modification Drawings Project No. 146FRE1400 October 31, 2014 CLS Engineering PLLC Mount Modification Drawings: AT&T Side ID: 478-122 October 12, 2016

    FDH Velocitel Previous Structural Analysis Project No. 16PWTM1400 November 22, 2016 AT&T RFDS Site Name: ATA-Sea Trail Updated: January 21, 2017

    High Performance Services, Inc. - - - The basic design wind speed per the ANSI/TIA-222-G standard and 2012 NCSBC is 135 mph without ice and 30 mph with 1/4" radial ice. Ice is considered to increase in thickness with height. Furthermore, this structure was analyzed as a Class II structure in Exposure Category C, topographical factor of 1 with crest height of 0 ft, and Spectral Response Accelerations of SS=0.427 and S1=0.128. Note: Per Section 2.7.3 of the ANSI/TIA-222-G Standard, the seismic/earthquake loading effects can be ignored if the spectral response acceleration at short periods (SS) is less than or equal to 1.00. The tower’s location mandates a design SS of less than 1.00, thus seismic loading was not considered as part of the analysis of this structure. Conclusions With the antenna configuration in place per Table 1 we have determined the tower stress level to be sufficient and the foundation(s) to be sufficient pursuant to the requirements stipulated by ANSI/TIA-222-G Structural Standard for Antenna Supporting Structures and Antennas and 2012 North Carolina State Building Code (NCSBC) provided the Recommendations listed below are satisfied. For a more detailed description of the analysis of the tower, see the Results section of this report. Our structural analysis has been performed assuming all information provided to FDH Velocitel Engineering, PLLC is accurate (i.e., the structure member information, tower layout, existing antenna loading, and proposed antenna loading) and that the tower has been properly erected and maintained per the original design drawings. Recommendations To ensure the requirements of the current analysis standards are met with the antenna configuration in place per Table 1, we have the following recommendations:

    1. Feed lines to be installed as shown in Figure 1 in the Appendix. 2. RRU/RRH Stipulation: The equipment may be installed in any arrangement as determined by the client. 3. Modifications outlined in FDH Engineering, Inc. (Project No. 146FRE1400) Modification Drawings for a 298’

    Self-Support Tower dated October 31, 2014 must be installed as specified for this analysis to be valid. 4. A foundation mapping should be performed to determine the dimensions of the existing foundations.

    STR-RPT-10100 3

    Reviewed For Code Compliance

  • Structural Analysis Report High Performance Services LLC

    Site ID: 110028-A February 09, 2017

    APPURTENANCE LISTING The antennas and equipment, with their corresponding feed lines, considered for this analysis are shown in Table 1. If the actual layout determined in the field deviates from the layout, FDH Velocitel Engineering, PLLC should be contacted to perform a revised analysis. Table 1 - Appurtenance Loading Existing Loading:

    Antenna Elevation (ft.) Description Feed Lines Carrier

    Mount Elevation (ft.) Mount Type

    296

    (3) Kathrein 741 989 (6) Andrew HBX-6517DS-VTM

    (3) Commscope SBNHH-1D65C (3) Ericsson RRUS-11

    (2) Raycap DC6-48-60-18-8F

    (15) 1-5/8" (4) 7/8” Power (1) 1/2” Fiber (1) 3/8” RET

    AT&T 296 (3) 12.5' T-Frames (Kenwood T1684KT12-4114)

    280 (3) Kathrein 741 989

    (3) Kathrein 800 10309 V01 (3) Ericsson RRUS-11

    (1) Raycap DC6-48-60-18-8F

    (6) 1-5/8” (2) 1-1/4” Power

    (1) 3/4" Fiber (1) 3/8” RET

    ATMC 280 (3) 10' T-Frames

    200 (1) Antel BCD-87010 (1) 7/8” Brunswick County 200 (1) 6’ Standoff

    Proposed Carrier Final Loading: Antenna

    Elevation (ft.) Description Feed Lines Carrier Mount

    Elevation (ft.) Mount Type

    296

    (3) Kathrein 741 989 (3) Commscope SBNHH-1D65C

    (3) Ericsson RRUS-32 B66 (6) Ericsson RRUS-11

    (2) Raycap DC6-48-60-18-8F

    (3) 7/8” Power (2) 1/2” Fiber AT&T 296

    (3) 12.5' T-Frames w/ Mods (Kenwood T1684KT12-4114)

    STR-RPT-10100 4

    Reviewed For Code Compliance

  • Structural Analysis Report High Performance Services LLC

    Site ID: 110028-A February 09, 2017

    RESULTS The following material grades for individual members were used for analysis:

    Table 2 - Material Grade

    Member Type Material Grade Legs A572-50

    Bracing A36 Bracing Bolts A325 Anchor Rods A354-BC

    Table 3 and Table 4 display the summary of capacities for the analyzed structure and its additional components. Values greater than 100% indicate locations where the maximum force in the member exceeds its capacity. Note: Capacities up to 105% are considered acceptable (except foundation soil interaction, up to 110% is considered acceptable). If the assumptions outlined in this report differ from actual field conditions, FDH Velocitel Engineering, PLLC should be contacted to perform a revised analysis. Furthermore, as no information pertaining to the allowable twist and sway requirements for the appurtenances was provided, deflection and rotation were not taken into consideration when performing this analysis. See the Appendix for detailed modeling information. Table 3 - Structure Member Capacities

    Section No. Elevation (ft.) Component Type Size % Capacity Pass / Fail T1 298 - 296.667 Leg 1 3/4 1.0 Pass T2 296.667 - 293.334 Leg 1 3/4 9.5 Pass T3 293.334 - 286.667 Leg 1 3/4 40.3 Pass T4 286.667 - 280 Leg 1 3/4 76.2 Pass

    T5 280 - 260 Leg SR2 1/2 + 180 deg 3.5 OD x 0.3 (v4.13) 75.4 Pass

    T6 260 - 240 Leg 3 1/4 82.4 Pass T7 240 - 220 Leg 3 3/4 70.7 Pass T8 220 - 200 Leg 4 72.4 Pass T9 200 - 180 Leg 4 1/2 63.3 Pass T10 180 - 160 Leg 4 3/4 64.3 Pass T11 160 - 140 Leg 5 65.0 Pass T12 140 - 120 Leg 5 1/4 65.5 Pass T13 120 - 100 Leg 5 1/2 65.9 Pass T14 100 - 80 Leg 6 59.1 Pass T15 80 - 60 Leg 6 63.8 Pass T16 60 - 40 Leg 6 1/4 62.8 Pass T17 40 - 20 Leg 6 1/2 62.0 Pass T18 20 - 0 Leg 6 1/2 64.6 Pass T1 298 - 296.667 Diagonal 1 1/8 8.3 Pass T2 296.667 - 293.334 Diagonal 1 1/8 73.4 Pass T3 293.334 - 286.667 Diagonal 1 1/8 91.6 Pass T4 286.667 - 280 Diagonal SR1 1/8 + L2 x 2 x 1/4 NT (v4.13) 70.6 Pass T5 280 - 260 Diagonal 1 3/8 74.4 Pass

    T6 260 - 240 Diagonal L2 1/2x2 1/2x1/4 28.1 58.7 (b) Pass

    T7 240 - 220 Diagonal L2 1/2x2 1/2x1/4 29.1 51.4 (b) Pass

    T8 220 - 200 Diagonal L2 1/2x2 1/2x1/4 37.7 58.4 (b) Pass

    T9 200 - 180 Diagonal L3 1/2x3 1/2x1/4 44 64.5 (b) Pass

    STR-RPT-10100 5

    Reviewed For Code Compliance

  • Structural Analysis Report High Performance Services LLC

    Site ID: 110028-A February 09, 2017

    Section No. Elevation (ft.) Component Type Size % Capacity Pass / Fail

    T10 180 - 160 Diagonal L3 1/2x3 1/2x1/4 54.3 70.3 (b) Pass

    T11 160 - 140 Diagonal L4x4x1/4 47.8 76.8 (b) Pass

    T12 140 - 120 Diagonal L4x4x5/16 48.7 68.8 (b) Pass

    T13 120 - 100 Diagonal L4x4x5/16 61.8 75.5 (b) Pass

    T14 100 - 80 Diagonal L4x4x5/16 58.7 60.6 (b) Pass

    T15 80 - 60 Diagonal L5x5x5/16 40.4 59.0 (b) Pass

    T16 60 - 40 Diagonal L5x5x5/16 52.6 66.2 (b) Pass

    T17 40 - 20 Diagonal L5x5x5/16 68.2 76.2 (b) Pass

    T18 20 - 0 Diagonal L5x5x3/8 54.4 91.0 (b) Pass

    T3 293.334 - 286.667 Horizontal 1 3.9 Pass T4 286.667 - 280 Horizontal 1 7.4 Pass T5 280 - 260 Horizontal 1 22.6 Pass

    T18 20 - 0 Horizontal L5x5x5/16 48.2 52.5 (b) Pass

    T9 200 - 180 Secondary Horizontal L3x3x3/16 28.5 58.8 (b) Pass

    T10 180 - 160 Secondary Horizontal L3x3x3/16 38.5 68.1 (b) Pass

    T11 160 - 140 Secondary Horizontal L3x3x3/16 52.5 76.1 (b) Pass

    T12 140 - 120 Secondary Horizontal L3x3x1/4 55.6 64.6 (b) Pass

    T13 120 - 100 Secondary Horizontal L3 1/2x3 1/2x1/4 47.6 61.0 (b) Pass

    T14 100 - 80 Secondary Horizontal L3 1/2x3 1/2x1/4 65.1 66.7 (b) Pass

    T15 80 - 60 Secondary Horizontal L4x4x1/4 58.3 72.0 (b) Pass

    T16 60 - 40 Secondary Horizontal L4x4x5/16 62.6 Pass T17 40 - 20 Secondary Horizontal L4x4x3/8 68.3 Pass T1 298 - 296.667 Top Girt 1 6.4 Pass T2 296.667 - 293.334 Top Girt 1 36.6 Pass T3 293.334 - 286.667 Top Girt 1 7.4 Pass T4 286.667 - 280 Top Girt 1 2.3 Pass T5 280 - 260 Top Girt 1 17.4 Pass

    T6 260 - 240 Top Girt L2x2x1/8 68.8 102.4 (b) Pass

    T18 20 - 0 Redund Horz 1 Bracing L3 1/2x3 1/2x5/16 39.5 Pass T18 20 - 0 Redund Diag 1 Bracing L3 1/2x3 1/2x5/16 39.2 Pass T18 20 - 0 Inner Bracing L3 1/2x3 1/2x1/4 0.4 Pass

    Table 4 – Additional Structure Component Capacities

    Elevation (ft.) Component % Capacity Pass / Fail Notes 0 Anchor Rods 55.5 Pass - 0 Base Foundation (Soil Interaction) 67.6 Pass - 0 Base Foundation (Structural) 52.2 Pass -

    STR-RPT-10100 6

    Reviewed For Code Compliance

  • Structural Analysis Report High Performance Services LLC

    Site ID: 110028-A February 09, 2017

    GENERAL COMMENTS This engineering analysis is based upon the theoretical capacity of the structure. It is not a condition assessment of the tower and its foundation. It is the responsibility of High Performance Services LLC to verify that the tower modeled and analyzed is the correct structure (with accurate antenna loading information) modeled. If there are substantial modifications to be made or the assumptions made in this analysis are not accurate, FDH Velocitel Engineering, PLLC should be notified immediately to perform a revised analysis. LIMITATIONS All opinions and conclusions are considered accurate to a reasonable degree of engineering certainty based upon the evidence available at the time of this report. All opinions and conclusions are subject to revision based upon receipt of new or additional/updated information. All services are provided exercising a level of care and diligence equivalent to the standard and care of our profession. No other warranty or guarantee, expressed or implied, is offered. Our services are confidential in nature and we will not release this report to any other party without the client’s consent. The use of this engineering work is limited to the express purpose for which it was commissioned and it may not be reused, copied, or distributed for any other purpose without the written consent of FDH Velocitel Engineering, PLLC.

    STR-RPT-10100 7

    Reviewed For Code Compliance

  • Structural Analysis Report High Performance Services LLC

    Site ID: 110028-A February 09, 2017

    APPENDIX STR-RPT-10100 8

    Reviewed For Code Compliance

  • Structural Analysis Report High Performance Services LLC

    Site ID: 110028-A February 09, 2017

    Figure 1: Assumed Feed Line Layout

    STR-RPT-10100 9

    Reviewed For Code Compliance

  • Tower Analysis

    FDH Velocitel 6521 Meridien Drive, Suite 107 Raleigh, North Carolina 27616

    Phone: (919) 755-1012 FAX: (919) 755-1031

    Job: ATA-Sea Trail (478-122), 110028-A Project: 17PVVN1400 Client: High Performance Services LLC Drawn by: AVago App'd: Code: TIA-222-G Date: 02/09/17 Scale: NTS Path:

    C:\Users\avago\Desktop\17PVVN1400-STRSOO_AT&T\R.0\Analysis\ReportedTower\478-122 Sea Trail.eri Dwg No. E-1

    298.0 ft296.7 ft293.3 ft

    286.7 ft

    280.0 ft

    260.0 ft

    240.0 ft

    220.0 ft

    200.0 ft

    180.0 ft

    160.0 ft

    140.0 ft

    120.0 ft

    100.0 ft

    80.0 ft

    60.0 ft

    40.0 ft

    20.0 ft

    0.0 ft

    REACTIONS - 135 mph WINDTORQUE 17 kip-ft

    136 KSHEAR

    19455 kip-ftMOMENT

    124 KAXIAL

    30 mph WIND - 0.2500 in ICETORQUE 0 kip-ft

    6 KSHEAR

    827 kip-ftMOMENT

    154 KAXIAL

    SHEAR: 75 KUPLIFT: -764 K

    SHEAR: 89 KDOWN: 905 K

    MAX. CORNER REACTIONS AT BASE:

    ARE FACTOREDALL REACTIONS

    Sec

    tion

    T1 T2

    T3T4

    T5T6

    T7T8

    T9T1

    0T1

    1T1

    2T1

    3T1

    4T1

    5T1

    6T1

    7T1

    8

    Leg

    sS

    R 1

    3/4

    AS

    R 3

    1/4

    SR

    3 3

    /4S

    R 4

    SR

    4 1

    /2S

    R 4

    3/4

    SR

    5S

    R 5

    1/4

    SR

    5 1

    /2S

    R 6

    SR

    6 1

    /4S

    R 6

    1/2

    Leg

    Gra

    deA

    572-

    50A

    500-

    46A

    572-

    50 D

    iago

    nals

    SR

    1 1

    /8B

    SR

    1 3

    /8L2

    1/2

    x2 1

    /2x1

    /4L3

    1/2

    x3 1

    /2x1

    /4L4

    x4x1

    /4L4

    x4x5

    /16

    L5x5

    x5/1

    6L5

    x5x3

    /8 D

    iago

    nal G

    rade

    A36

    Top

    Girt

    sS

    R 1

    L2x2

    x1/8

    N.A

    . H

    oriz

    onta

    lsC

    SR

    1N

    .A.

    L5x5

    x5/1

    6 S

    ec. H

    oriz

    onta

    lsN

    .A.

    L3x3

    x3/1

    6L3

    x3x1

    /4L3

    1/2

    x3 1

    /2x1

    /4L4

    x4x1

    /4L4

    x4x5

    /16

    L4x4

    x3/8

    N.A

    . R

    ed. H

    oriz

    onta

    lsN

    .A.

    D R

    ed. D

    iago

    nals

    N.A

    .D

    Inn

    er B

    raci

    ngN

    .A.

    L3 1

    /2x3

    1/2

    x1/4

    Fac

    e W

    idth

    (ft)

    45.

    57

    8.5

    1011

    .513

    14.5

    1618

    2022

    2426

    # P

    anel

    s @

    (ft)

    EF

    4 @

    3.3

    335

    6 @

    3.3

    3333

    12 @

    520

    @ 1

    0 W

    eigh

    t (K

    )0.

    10.

    20.

    30.

    32.

    02.

    43.

    03.

    54.

    44.

    95.

    56.

    57.

    28.

    39.

    210

    .211

    .211

    .490

    .5

    Lightning Rod 298 Beacon 298 741 989 w/ Mount Pipe 296 741 989 w/ Mount Pipe 296 741 989 w/ Mount Pipe 296 SBNHH-1D65C w/ Mount Pipe 296 SBNHH-1D65C w/ Mount Pipe 296 SBNHH-1D65C w/ Mount Pipe 296 RRUS-32 B66 296 RRUS-32 B66 296 RRUS-32 B66 296 RRUS-11 296 RRUS-11 296 RRUS-11 296 DC6-48-60-18-8F 296 (3) 12.5' T-Frames w/ Mods (Kenwood T1684KT12-4114)

    296 RRUS-11 296 RRUS-11 296 RRUS-11 296 DC6-48-60-18-8F 296 741 989 w/ Mount Pipe 280 741 989 w/ Mount Pipe 280 741 989 w/ Mount Pipe 280 800 10309 V01 w/ Mount Pipe 280 800 10309 V01 w/ Mount Pipe 280 800 10309 V01 w/ Mount Pipe 280 RRUS-11 280 RRUS-11 280 RRUS-11 280 DC6-48-60-18-8F 280 (3) 10' T-Frames 280 BCD-87010 200 (1) Standoff 200 Sidemarker 150 Sidemarker 150 Sidemarker 150DESIGNED APPURTENANCE LOADINGTYPE TYPEELEVATION ELEVATION

    Lightning Rod 298 Beacon 298 741 989 w/ Mount Pipe 296 741 989 w/ Mount Pipe 296 741 989 w/ Mount Pipe 296 SBNHH-1D65C w/ Mount Pipe 296 SBNHH-1D65C w/ Mount Pipe 296 SBNHH-1D65C w/ Mount Pipe 296 RRUS-32 B66 296 RRUS-32 B66 296 RRUS-32 B66 296 RRUS-11 296 RRUS-11 296 RRUS-11 296 DC6-48-60-18-8F 296 (3) 12.5' T-Frames w/ Mods (Kenwood T1684KT12-4114)

    296

    RRUS-11 296 RRUS-11 296

    RRUS-11 296 DC6-48-60-18-8F 296 741 989 w/ Mount Pipe 280 741 989 w/ Mount Pipe 280 741 989 w/ Mount Pipe 280 800 10309 V01 w/ Mount Pipe 280 800 10309 V01 w/ Mount Pipe 280 800 10309 V01 w/ Mount Pipe 280 RRUS-11 280 RRUS-11 280 RRUS-11 280 DC6-48-60-18-8F 280 (3) 10' T-Frames 280 BCD-87010 200 (1) Standoff 200 Sidemarker 150 Sidemarker 150 Sidemarker 150

    SYMBOL LISTMARK MARKSIZE SIZE

    A SR2 1/2 + 180 deg 3.5 OD x 0.3 (v4.13)B SR1 1/8 + L2 x 2 x 1/4 NT (v4.13)C N.A.

    D L3 1/2x3 1/2x5/16E 1 @ 1.333F 1 @ 3.333

    MATERIAL STRENGTHGRADE GRADEFy FyFu Fu

    A572-50 50 ksi 65 ksi A36 36 ksi 58 ksi

    A500-46 46 ksi 62 ksi

    TOWER DESIGN NOTES1. Tower is located in Brunswick County, North Carolina.2. Tower designed for Exposure C to the TIA-222-G Standard.3. Tower designed for a 135 mph basic wind in accordance with the TIA-222-G Standard.4. Tower is also designed for a 30 mph basic wind with 0.25 in ice. Ice is considered to increase

    in thickness with height.5. Deflections are based upon a 60 mph wind.6. Tower Structure Class II.7. Topographic Category 1 with Crest Height of 0.00 ft8. TOWER RATING: 102.4%

    Reviewed For Code Compliance

  • ttnnxxTToowweerr Job ATA-Sea Trail (478-122), 110028-A Page

    1 of 32

    FDH Velocitel 6521 Meridien Drive, Suite 107

    Project 17PVVN1400

    Date 13:35:27 02/09/17

    Raleigh, North Carolina 27616 Phone: (919) 755-1012 FAX: (919) 755-1031

    Client High Performance Services LLC

    Designed by AVago

    Tower Input Data The main tower is a 3x free standing tower with an overall height of 298.00 ft above the ground line. The base of the tower is set at an elevation of 0.00 ft above the ground line. The face width of the tower is 4.00 ft at the top and 26.00 ft at the base. This tower is designed using the TIA-222-G standard. The following design criteria apply:

    • Tower is located in Brunswick County, North Carolina. • Basic wind speed of 135 mph. • Structure Class II. • Exposure Category C. • Topographic Category 1. • Crest Height 0.00 ft. • Nominal ice thickness of 0.2500 in. • Ice thickness is considered to increase with height. • Ice density of 56 pcf. • A wind speed of 30 mph is used in combination with ice. • Temperature drop of 50 °F. • Deflections calculated using a wind speed of 60 mph. • A non-linear (P-delta) analysis was used. • Pressures are calculated at each section. • Stress ratio used in tower member design is 1. • Local bending stresses due to climbing loads, feed line supports, and appurtenance mounts are not considered.

    Options

    Consider Moments - Legs Distribute Leg Loads As Uniform Use ASCE 10 X-Brace Ly Rules Consider Moments - Horizontals Assume Legs Pinned √ Calculate Redundant Bracing Forces Consider Moments - Diagonals √ Assume Rigid Index Plate Ignore Redundant Members in FEA Use Moment Magnification √ Use Clear Spans For Wind Area √ SR Leg Bolts Resist Compression √ Use Code Stress Ratios √ Use Clear Spans For KL/r All Leg Panels Have Same Allowable √ Use Code Safety Factors - Guys Retension Guys To Initial Tension Offset Girt At Foundation Escalate Ice √ Bypass Mast Stability Checks √ Consider Feed Line Torque Always Use Max Kz √ Use Azimuth Dish Coefficients √ Include Angle Block Shear Check Use Special Wind Profile √ Project Wind Area of Appurt. Use TIA-222-G Bracing Resist. Exemption √ Include Bolts In Member Capacity Autocalc Torque Arm Areas Use TIA-222-G Tension Splice Exemption Leg Bolts Are At Top Of Section Add IBC .6D+W Combination Poles √ Secondary Horizontal Braces Leg √ Sort Capacity Reports By Component Include Shear-Torsion Interaction Use Diamond Inner Bracing (4 Sided) Triangulate Diamond Inner Bracing Always Use Sub-Critical Flow √ SR Members Have Cut Ends Treat Feed Line Bundles As Cylinder Use Top Mounted Sockets √ SR Members Are Concentric

    Reviewed For Code Compliance

  • ttnnxxTToowweerr Job ATA-Sea Trail (478-122), 110028-A Page

    2 of 32

    FDH Velocitel 6521 Meridien Drive, Suite 107

    Project 17PVVN1400

    Date 13:35:27 02/09/17

    Raleigh, North Carolina 27616 Phone: (919) 755-1012 FAX: (919) 755-1031

    Client High Performance Services LLC

    Designed by AVago

    Leg B Leg C

    Leg A

    Face

    A Face B

    Face C

    Triangular Tower

    Wind Normal

    Wind 90

    Wind 180

    Z

    X

    Tower Section Geometry

    Tower Section

    Tower Elevation

    ft

    Assembly Database

    Description Section Width

    ft

    Number of

    Sections

    Section Length

    ft

    T1 298.00-296.67 4.00 1 1.33 T2 296.67-293.33 4.00 1 3.33 T3 293.33-286.67 4.00 1 6.67 T4 286.67-280.00 4.00 1 6.67 T5 280.00-260.00 4.00 1 20.00 T6 260.00-240.00 4.00 1 20.00 T7 240.00-220.00 5.50 1 20.00 T8 220.00-200.00 7.00 1 20.00 T9 200.00-180.00 8.50 1 20.00

    T10 180.00-160.00 10.00 1 20.00 T11 160.00-140.00 11.50 1 20.00 T12 140.00-120.00 13.00 1 20.00 T13 120.00-100.00 14.50 1 20.00 T14 100.00-80.00 16.00 1 20.00 T15 80.00-60.00 18.00 1 20.00 T16 60.00-40.00 20.00 1 20.00 T17 40.00-20.00 22.00 1 20.00 T18 20.00-0.00 24.00 1 20.00

    Tower Section Geometry (cont’d)

    Reviewed For Code Compliance

  • ttnnxxTToowweerr Job ATA-Sea Trail (478-122), 110028-A Page

    3 of 32

    FDH Velocitel 6521 Meridien Drive, Suite 107

    Project 17PVVN1400

    Date 13:35:27 02/09/17

    Raleigh, North Carolina 27616 Phone: (919) 755-1012 FAX: (919) 755-1031

    Client High Performance Services LLC

    Designed by AVago

    Tower Section

    Tower Elevation

    ft

    Diagonal Spacing

    ft

    Bracing Type

    Has K Brace

    End Panels

    Has Horizontals

    Top Girt Offset

    in

    Bottom Girt Offset

    in

    T1 298.00-296.67 1.33 Diag Down No Yes 0.0000 0.0000 T2 296.67-293.33 3.33 Diag Up No Yes 0.0000 0.0000 T3 293.33-286.67 3.33 K Brace Left No Yes 0.0000 0.0000 T4 286.67-280.00 3.33 K Brace Left No Yes 0.0000 0.0000 T5 280.00-260.00 3.33 K Brace Left No Yes 0.0000 0.0000 T6 260.00-240.00 5.00 X Brace No No 0.0000 0.0000 T7 240.00-220.00 5.00 X Brace No No 0.0000 0.0000 T8 220.00-200.00 5.00 X Brace No No 0.0000 0.0000 T9 200.00-180.00 10.00 X Brace No Yes 0.0000 0.0000

    T10 180.00-160.00 10.00 X Brace No Yes 0.0000 0.0000 T11 160.00-140.00 10.00 X Brace No Yes 0.0000 0.0000 T12 140.00-120.00 10.00 X Brace No Yes 0.0000 0.0000 T13 120.00-100.00 10.00 X Brace No Yes 0.0000 0.0000 T14 100.00-80.00 10.00 X Brace No Yes 0.0000 0.0000 T15 80.00-60.00 10.00 X Brace No Yes 0.0000 0.0000 T16 60.00-40.00 10.00 X Brace No Yes 0.0000 0.0000 T17 40.00-20.00 10.00 X Brace No Yes 0.0000 0.0000 T18 20.00-0.00 10.00 Double K1 No Yes 0.0000 0.0000

    Tower Section Geometry (cont’d)

    Tower Elevation

    ft

    Leg Type

    Leg Size

    Leg Grade

    Diagonal Type

    Diagonal Size

    Diagonal Grade

    T1 298.00-296.67 Solid Round 1 3/4 A572-50 (50 ksi)

    Solid Round 1 1/8 A36 (36 ksi)

    T2 296.67-293.33 Solid Round 1 3/4 A572-50 (50 ksi)

    Solid Round 1 1/8 A36 (36 ksi)

    T3 293.33-286.67 Solid Round 1 3/4 A572-50 (50 ksi)

    Solid Round 1 1/8 A36 (36 ksi)

    T4 286.67-280.00 Solid Round 1 3/4 A572-50 (50 ksi)

    Arbitrary Shape

    SR1 1/8 + L2 x 2 x 1/4 NT (v4.13)

    A36 (36 ksi)

    T5 280.00-260.00 Arbitrary Shape SR2 1/2 + 180 deg 3.5 OD x 0.3 (v4.13)

    A500-46 (46 ksi)

    Solid Round 1 3/8 A36 (36 ksi)

    T6 260.00-240.00 Solid Round 3 1/4 A572-50 (50 ksi)

    Equal Angle L2 1/2x2 1/2x1/4 A36 (36 ksi)

    T7 240.00-220.00 Solid Round 3 3/4 A572-50 (50 ksi)

    Equal Angle L2 1/2x2 1/2x1/4 A36 (36 ksi)

    T8 220.00-200.00 Solid Round 4 A572-50 (50 ksi)

    Equal Angle L2 1/2x2 1/2x1/4 A36 (36 ksi)

    T9 200.00-180.00 Solid Round 4 1/2 A572-50 (50 ksi)

    Equal Angle L3 1/2x3 1/2x1/4 A36 (36 ksi)

    T10 180.00-160.00

    Solid Round 4 3/4 A572-50 (50 ksi)

    Equal Angle L3 1/2x3 1/2x1/4 A36 (36 ksi)

    T11 160.00-140.00

    Solid Round 5 A572-50 (50 ksi)

    Equal Angle L4x4x1/4 A36 (36 ksi)

    T12 140.00-120.00

    Solid Round 5 1/4 A572-50 (50 ksi)

    Equal Angle L4x4x5/16 A36 (36 ksi)

    T13 120.00-100.00

    Solid Round 5 1/2 A572-50 (50 ksi)

    Equal Angle L4x4x5/16 A36 (36 ksi)

    T14 100.00-80.00 Solid Round 6 A572-50 (50 ksi)

    Equal Angle L4x4x5/16 A36 (36 ksi)

    T15 80.00-60.00 Solid Round 6 A572-50 (50 ksi)

    Equal Angle L5x5x5/16 A36 (36 ksi)

    T16 60.00-40.00 Solid Round 6 1/4 A572-50 (50 ksi)

    Equal Angle L5x5x5/16 A36 (36 ksi)

    T17 40.00-20.00 Solid Round 6 1/2 A572-50 Equal Angle L5x5x5/16 A36

    Reviewed For Code Compliance

  • ttnnxxTToowweerr Job ATA-Sea Trail (478-122), 110028-A Page

    4 of 32

    FDH Velocitel 6521 Meridien Drive, Suite 107

    Project 17PVVN1400

    Date 13:35:27 02/09/17

    Raleigh, North Carolina 27616 Phone: (919) 755-1012 FAX: (919) 755-1031

    Client High Performance Services LLC

    Designed by AVago

    Tower Elevation

    ft

    Leg Type

    Leg Size

    Leg Grade

    Diagonal Type

    Diagonal Size

    Diagonal Grade

    (50 ksi) (36 ksi) T18 20.00-0.00 Solid Round 6 1/2 A572-50

    (50 ksi) Equal Angle L5x5x3/8 A36

    (36 ksi)

    Tower Section Geometry (cont’d)

    Tower Elevation

    ft

    Top Girt Type

    Top Girt Size

    Top Girt Grade

    Bottom Girt Type

    Bottom Girt Size

    Bottom Girt Grade

    T1 298.00-296.67 Solid Round 1 A36 (36 ksi)

    Solid Round A36 (36 ksi)

    T2 296.67-293.33 Solid Round 1 A36 (36 ksi)

    Solid Round A36 (36 ksi)

    T3 293.33-286.67 Solid Round 1 A36 (36 ksi)

    Solid Round A36 (36 ksi)

    T4 286.67-280.00 Solid Round 1 A36 (36 ksi)

    Solid Round A36 (36 ksi)

    T5 280.00-260.00 Solid Round 1 A36 (36 ksi)

    Solid Round A36 (36 ksi)

    T6 260.00-240.00 Equal Angle L2x2x1/8 A36 (36 ksi)

    Solid Round A36 (36 ksi)

    Tower Section Geometry (cont’d)

    Tower Elevation

    ft

    No. of

    Mid Girts

    Mid Girt Type

    Mid Girt Size

    Mid Girt Grade

    Horizontal Type

    Horizontal Size

    Horizontal Grade

    T1 298.00-296.67 None Flat Bar A36 (36 ksi)

    Solid Round 1 A36 (36 ksi)

    T2 296.67-293.33 None Flat Bar A36 (36 ksi)

    Solid Round 1 A36 (36 ksi)

    T3 293.33-286.67 None Flat Bar A36 (36 ksi)

    Solid Round 1 A36 (36 ksi)

    T4 286.67-280.00 None Flat Bar A36 (36 ksi)

    Solid Round 1 A36 (36 ksi)

    T5 280.00-260.00 None Flat Bar A36 (36 ksi)

    Solid Round 1 A36 (36 ksi)

    T18 20.00-0.00 None Flat Bar A36 (36 ksi)

    Equal Angle L5x5x5/16 A36 (36 ksi)

    Tower Section Geometry (cont’d)

    Tower Elevation

    ft

    Secondary Horizontal Type

    Secondary Horizontal Size

    Secondary Horizontal

    Grade

    Inner Bracing Type

    Inner Bracing Size

    Inner Bracing Grade

    Reviewed For Code Compliance

  • ttnnxxTToowweerr Job ATA-Sea Trail (478-122), 110028-A Page

    5 of 32

    FDH Velocitel 6521 Meridien Drive, Suite 107

    Project 17PVVN1400

    Date 13:35:27 02/09/17

    Raleigh, North Carolina 27616 Phone: (919) 755-1012 FAX: (919) 755-1031

    Client High Performance Services LLC

    Designed by AVago

    Tower Elevation

    ft

    Secondary Horizontal Type

    Secondary Horizontal Size

    Secondary Horizontal

    Grade

    Inner Bracing Type

    Inner Bracing Size

    Inner Bracing Grade

    T9 200.00-180.00 Equal Angle L3x3x3/16 A36 (36 ksi)

    Solid Round A572-50 (50 ksi)

    T10 180.00-160.00

    Equal Angle L3x3x3/16 A36 (36 ksi)

    Solid Round A572-50 (50 ksi)

    T11 160.00-140.00

    Equal Angle L3x3x3/16 A36 (36 ksi)

    Solid Round A572-50 (50 ksi)

    T12 140.00-120.00

    Equal Angle L3x3x1/4 A36 (36 ksi)

    Solid Round A572-50 (50 ksi)

    T13 120.00-100.00

    Equal Angle L3 1/2x3 1/2x1/4 A36 (36 ksi)

    Solid Round A572-50 (50 ksi)

    T14 100.00-80.00 Equal Angle L3 1/2x3 1/2x1/4 A36 (36 ksi)

    Solid Round A572-50 (50 ksi)

    T15 80.00-60.00 Equal Angle L4x4x1/4 A36 (36 ksi)

    Solid Round A572-50 (50 ksi)

    T16 60.00-40.00 Equal Angle L4x4x5/16 A36 (36 ksi)

    Solid Round A572-50 (50 ksi)

    T17 40.00-20.00 Equal Angle L4x4x3/8 A36 (36 ksi)

    Solid Round A572-50 (50 ksi)

    T18 20.00-0.00 Equal Angle A36 (36 ksi)

    Equal Angle L3 1/2x3 1/2x1/4 A36 (36 ksi)

    Tower Section Geometry (cont’d)

    Tower Elevation

    ft

    Redundant Bracing Grade

    Redundant Type

    Redundant Size

    K Factor

    T18 20.00-0.00

    A36 (36 ksi)

    Horizontal (1) Diagonal (1)

    Equal Angle Equal Angle

    L3 1/2x3 1/2x5/16 L3 1/2x3 1/2x5/16

    1 1

    Tower Section Geometry (cont’d)

    Tower Elevation

    ft

    Gusset Area

    (per face)

    ft2

    Gusset Thickness

    in

    Gusset Grade Adjust. Factor Af

    Adjust. Factor

    Ar

    Weight Mult.

    Double Angle Stitch Bolt Spacing

    Diagonals in

    Double Angle Stitch Bolt Spacing

    Horizontals in

    Double Angle Stitch Bolt Spacing

    Redundants in

    T1 298.00-296.67

    0.00 0.0000 A36 (36 ksi)

    1 1 1 36.0000 36.0000 36.0000

    T2 296.67-293.33

    0.00 0.0000 A36 (36 ksi)

    1 1 1 36.0000 36.0000 36.0000

    T3 293.33-286.67

    0.00 0.0000 A36 (36 ksi)

    1 1 1 36.0000 36.0000 36.0000

    T4 286.67-280.00

    0.00 0.0000 A36 (36 ksi)

    1 1 1 36.0000 36.0000 36.0000

    T5 280.00-260.00

    0.00 0.0000 A36 (36 ksi)

    1 1 1 36.0000 36.0000 36.0000

    T6 260.00-240.00

    0.00 0.0000 A36 (36 ksi)

    1 1 1 36.0000 36.0000 36.0000

    T7 240.00-220.00

    0.00 0.0000 A36 (36 ksi)

    1 1 1 36.0000 36.0000 36.0000

    T8 0.00 0.0000 A36 1 1 1 36.0000 36.0000 36.0000 Reviewed For Code Compliance

  • ttnnxxTToowweerr Job ATA-Sea Trail (478-122), 110028-A Page

    6 of 32

    FDH Velocitel 6521 Meridien Drive, Suite 107

    Project 17PVVN1400

    Date 13:35:27 02/09/17

    Raleigh, North Carolina 27616 Phone: (919) 755-1012 FAX: (919) 755-1031

    Client High Performance Services LLC

    Designed by AVago

    Tower Elevation

    ft

    Gusset Area

    (per face)

    ft2

    Gusset Thickness

    in

    Gusset Grade Adjust. Factor Af

    Adjust. Factor

    Ar

    Weight Mult.

    Double Angle Stitch Bolt Spacing

    Diagonals in

    Double Angle Stitch Bolt Spacing

    Horizontals in

    Double Angle Stitch Bolt Spacing

    Redundants in

    220.00-200.00 (36 ksi) T9

    200.00-180.00 0.00 0.0000 A36

    (36 ksi) 1 1 1 36.0000 36.0000 36.0000

    T10 180.00-160.00

    0.00 0.0000 A36 (36 ksi)

    1 1 1 36.0000 36.0000 36.0000

    T11 160.00-140.00

    0.00 0.0000 A36 (36 ksi)

    1 1 1 36.0000 36.0000 36.0000

    T12 140.00-120.00

    0.00 0.0000 A36 (36 ksi)

    1 1 1 36.0000 36.0000 36.0000

    T13 120.00-100.00

    0.00 0.0000 A36 (36 ksi)

    1 1 1 36.0000 36.0000 36.0000

    T14 100.00-80.00

    0.00 0.0000 A36 (36 ksi)

    1 1 1 36.0000 36.0000 36.0000

    T15 80.00-60.00

    0.00 0.0000 A36 (36 ksi)

    1 1 1 36.0000 36.0000 36.0000

    T16 60.00-40.00

    0.00 0.0000 A36 (36 ksi)

    1 1 1 36.0000 36.0000 36.0000

    T17 40.00-20.00

    0.00 0.0000 A36 (36 ksi)

    1 1 1 36.0000 36.0000 36.0000

    T18 20.00-0.00 0.00 0.0000 A36 (36 ksi)

    1 1 1 36.0000 36.0000 36.0000

    Tower Section Geometry (cont’d)

    K Factors1

    Tower Elevation

    ft

    Calc K

    Single Angles

    Calc K

    Solid Rounds

    Legs X Brace Diags

    X Y

    K Brace Diags

    X Y

    Single Diags

    X Y

    Girts

    X Y

    Horiz.

    X Y

    Sec. Horiz.

    X Y

    Inner Brace

    X Y

    T1 298.00-296.67

    No Yes 1 1 1

    1 1

    1 1

    1 1

    1 1

    1 1

    1 1

    T2 296.67-293.33

    No Yes 1 1 1

    1 1

    1 1

    1 1

    1 1

    1 1

    1 1

    T3 293.33-286.67

    No Yes 1 1 1

    1 1

    1 1

    1 1

    1 1

    1 1

    1 1

    T4 286.67-280.00

    Yes Yes 1 1 1

    1.066 1.066

    1 1

    1 1

    1 1

    1 1

    1 1

    T5 280.00-260.00

    Yes Yes 1.18 1 1

    1 1

    1 1

    1 1

    1 1

    1 1

    1 1

    T6 260.00-240.00

    Yes Yes 1 1 1

    1 1

    1 1

    1 1

    1 1

    1 1

    1 1

    T7 240.00-220.00

    Yes Yes 1 1 1

    1 1

    1 1

    1 1

    1 1

    1 1

    1 1

    T8 220.00-200.00

    Yes Yes 1 1 1

    1 1

    1 1

    1 1

    1 1

    1 1

    1 1

    T9 200.00-180.00

    No Yes 1 1 1

    1 1

    1 1

    1 1

    1 1

    1 0.5

    1 1

    T10 180.00-160.00

    No Yes 1 1 1

    1 1

    1 1

    1 1

    1 1

    1 0.5

    1 1

    T11 160.00-140.00

    No Yes 1 1 1

    1 1

    1 1

    1 1

    1 1

    1 0.5

    1 1

    T12 140.00-120.00

    No Yes 1 1 1

    1 1

    1 1

    1 1

    1 1

    1 0.5

    1 1

    T13 No Yes 1 1 1 1 1 1 1 1

    Reviewed For Code Compliance

  • ttnnxxTToowweerr Job ATA-Sea Trail (478-122), 110028-A Page

    7 of 32

    FDH Velocitel 6521 Meridien Drive, Suite 107

    Project 17PVVN1400

    Date 13:35:27 02/09/17

    Raleigh, North Carolina 27616 Phone: (919) 755-1012 FAX: (919) 755-1031

    Client High Performance Services LLC

    Designed by AVago

    K Factors1

    Tower Elevation

    ft

    Calc K

    Single Angles

    Calc K

    Solid Rounds

    Legs X Brace Diags

    X Y

    K Brace Diags

    X Y

    Single Diags

    X Y

    Girts

    X Y

    Horiz.

    X Y

    Sec. Horiz.

    X Y

    Inner Brace

    X Y

    120.00-100.00 1 1 1 1 1 0.5 1 T14

    100.00-80.00 No Yes 1 1

    1 1 1

    1 1

    1 1

    1 1

    1 0.5

    1 1

    T15 80.00-60.00

    No Yes 1 1 1

    1 1

    1 1

    1 1

    1 1

    1 0.5

    1 1

    T16 60.00-40.00

    No Yes 1 1 1

    1 1

    1 1

    1 1

    1 1

    1 0.5

    1 1

    T17 40.00-20.00

    No Yes 1 1 1

    1 1

    1 1

    1 1

    1 1

    1 0.5

    1 1

    T18 20.00-0.00

    No Yes 1 1 1

    1 1

    1 1

    1 1

    1 1

    1 0.5

    1 1

    1Note: K factors are applied to member segment lengths. K-braces without inner supporting members will have the K factor in the out-of-plane direction applied to the overall length.

    Tower Section Geometry (cont’d)

    Tower Elevation

    ft

    Leg Diagonal Top Girt Bottom Girt Mid Girt Long Horizontal Short Horizontal

    Net Width Deduct

    in

    U

    Net Width Deduct

    in

    U

    Net Width Deduct

    in

    U

    Net Width

    Deduct in

    U

    Net Width

    Deduct in

    U

    Net Width

    Deduct in

    U

    Net Width

    Deduct in

    U

    T1 298.00-296.67

    0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75

    T2 296.67-293.33

    0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75

    T3 293.33-286.67

    0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75

    T4 286.67-280.00

    0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75

    T5 280.00-260.00

    0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75

    T6 260.00-240.00

    0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75

    T7 240.00-220.00

    0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75

    T8 220.00-200.00

    0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75

    T9 200.00-180.00

    0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75

    T10 180.00-160.00

    0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75

    T11 160.00-140.00

    0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75

    T12 140.00-120.00

    0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75

    T13 120.00-100.00

    0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75

    T14 100.00-80.00

    0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75

    T15 80.00-60.00

    0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 Reviewed For Code Compliance

  • ttnnxxTToowweerr Job ATA-Sea Trail (478-122), 110028-A Page

    8 of 32

    FDH Velocitel 6521 Meridien Drive, Suite 107

    Project 17PVVN1400

    Date 13:35:27 02/09/17

    Raleigh, North Carolina 27616 Phone: (919) 755-1012 FAX: (919) 755-1031

    Client High Performance Services LLC

    Designed by AVago

    Tower Elevation

    ft

    Leg Diagonal Top Girt Bottom Girt Mid Girt Long Horizontal Short Horizontal

    Net Width Deduct

    in

    U

    Net Width Deduct

    in

    U

    Net Width Deduct

    in

    U

    Net Width

    Deduct in

    U

    Net Width

    Deduct in

    U

    Net Width

    Deduct in

    U

    Net Width

    Deduct in

    U

    T16 60.00-40.00

    0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75

    T17 40.00-20.00

    0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75

    T18 20.00-0.00 0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75

    Tower Section Geometry (cont’d)

    Tower Elevation

    ft

    Leg Connection

    Type

    Leg Diagonal Top Girt Bottom Girt Mid Girt Long Horizontal Short Horizontal

    Bolt Size in

    No. Bolt Size in

    No. Bolt Size in

    No. Bolt Size in

    No. Bolt Size in

    No. Bolt Size in

    No. Bolt Size in

    No.

    T1 298.00-296.67

    Flange 0.0000 A325N

    0 0.0000 A325N

    0 0.6250 A325N

    0 0.6250 A325N

    0 0.6250 A325N

    0 0.0000 A325N

    0 0.0000 A325N

    0

    T2 296.67-293.33

    Flange 0.0000 A325N

    0 0.0000 A325N

    0 0.6250 A325N

    0 0.6250 A325N

    0 0.6250 A325N

    0 0.0000 A325N

    0 0.0000 A325N

    0

    T3 293.33-286.67

    Flange 0.0000 A325N

    0 0.0000 A325N

    0 0.6250 A325N

    0 0.0000 A325N

    0 0.6250 A325N

    0 0.0000 A325N

    0 0.0000 A325N

    0

    T4 286.67-280.00

    Flange 0.7500 A325N

    4 0.0000 A325N

    0 0.0000 A325N

    0 0.6250 A325N

    0 0.6250 A325N

    0 0.0000 A325N

    0 0.0000 A325N

    0

    T5 280.00-260.00

    Flange 1.0000 A325N

    4 0.0000 A325N

    0 0.6250 A325N

    0 0.0000 A325N

    0 0.6250 A325N

    0 0.0000 A325N

    0 0.0000 A325N

    0

    T6 260.00-240.00

    Flange 1.0000 A325N

    6 0.6250 A325N

    1 0.6250 A325N

    1 0.6250 A325N

    0 0.6250 A325N

    0 0.6250 A325N

    0 0.0000 A325N

    0

    T7 240.00-220.00

    Flange 1.2500 A325N>1''

    6 0.6250 A325N

    1 0.6250 A325N

    0 0.6250 A325N

    0 0.6250 A325N

    0 0.0000 A325N

    0 0.0000 A325N

    0

    T8 220.00-200.00

    Flange 1.2500 A325N>1''

    6 0.6250 A325N

    1 0.6250 A325N

    0 0.6250 A325N

    0 0.6250 A325N

    0 0.0000 A325N

    0 0.0000 A325N

    0

    T9 200.00-180.00

    Flange 1.5000 A325N>1''

    6 0.8750 A325N

    1 0.6250 A325N

    0 0.6250 A325N

    0 0.6250 A325N

    0 0.0000 A325N

    0 0.8750 A325N

    1

    T10 180.00-160.00

    Flange 1.5000 A325N>1''

    6 0.8750 A325N

    1 0.6250 A325N

    0 0.6250 A325N

    0 0.6250 A325N

    0 0.0000 A325N

    0 0.8750 A325N

    1

    T11 160.00-140.00

    Flange 1.7500 A325N>1''

    6 1.0000 A325N

    1 0.6250 A325N

    0 0.6250 A325N

    0 0.6250 A325N

    0 0.0000 A325N

    0 1.0000 A325N

    1

    T12 140.00-120.00

    Flange 1.7500 A325N>1''

    6 1.0000 A325N

    1 0.6250 A325N

    0 0.6250 A325N

    0 0.6250 A325N

    0 0.0000 A325N

    0 1.0000 A325N

    1

    T13 120.00-100.00

    Flange 2.0000 A325N>1''

    6 1.0000 A325N

    1 0.6250 A325N

    0 0.6250 A325N

    0 0.6250 A325N

    0 0.0000 A325N

    0 1.0000 A325N

    1

    T14 100.00-80.00

    Flange 2.0000 A325N>1''

    6 1.0000 A325N

    1 0.6250 A325N

    0 0.6250 A325N

    0 0.6250 A325N

    0 0.0000 A325N

    0 1.0000 A325N

    1

    T15 80.00-60.00

    Flange 2.0000 A325N>1''

    6 1.0000 A325N

    1 0.6250 A325N

    0 0.6250 A325N

    0 0.6250 A325N

    0 0.0000 A325N

    0 1.0000 A325N

    1

    T16 60.00-40.00

    Flange 2.0000 A325N>1''

    6 1.0000 A325N

    1 0.6250 A325N

    0 0.6250 A325N

    0 0.6250 A325N

    0 0.0000 A325N

    0 1.0000 A325N

    1

    T17 40.00-20.00

    Flange 2.2500 A325N>1''

    6 1.0000 A325N

    1 0.6250 A325N

    0 0.0000 A325N

    0 0.6250 A325N

    0 0.0000 A325N

    0 1.0000 A325N

    1

    T18 20.00-0.00 Flange 2.2500 A354-BC

    0 1.1250 A325N

    >1''

    1 0.0000 A325N

    0 0.6250 A325N

    0 0.6250 A325N

    0 1.1250 A325N>1''

    1 0.0000 A325N

    0

    Reviewed For Code Compliance

  • ttnnxxTToowweerr Job ATA-Sea Trail (478-122), 110028-A Page

    9 of 32

    FDH Velocitel 6521 Meridien Drive, Suite 107

    Project 17PVVN1400

    Date 13:35:27 02/09/17

    Raleigh, North Carolina 27616 Phone: (919) 755-1012 FAX: (919) 755-1031

    Client High Performance Services LLC

    Designed by AVago

    Feed Line/Linear Appurtenances - Entered As Round Or Flat

    Description Face or

    Leg

    Allow Shield

    Component Type

    Placement

    ft

    Face Offset

    in

    Lateral Offset

    (Frac FW)

    # # Per Row

    Clear Spacing

    in

    Width or Diameter

    in

    Perimeter

    in

    Weight

    plf Safety Line

    3/8 B No Ar (CaAa) 298.00 - 0.00 0.0000 0 1 1 0.0000 0.3750 0.22

    Climbing Ladder

    B No Af (CaAa) 298.00 - 0.00 0.0000 0 1 1 2.5000 2.5000 7.90

    *** Feedline

    Ladder (Af) 2'' A No Af (CaAa) 296.00 - 5.00 0.0000 0 1 1 2.0000 2.0000 6.30

    *** LDF4-50A(1/

    2'') A No Ar (CaAa) 296.00 - 5.00 0.0000 0.05 2 2 0.5000 0.6300 0.15

    LDF5-50A(7/8'')

    A No Ar (CaAa) 296.00 - 5.00 0.0000 0.035 3 3 0.5000 1.0900 0.33

    *** Feedline

    Ladder (Af) 2'' C No Af (CaAa) 280.00 - 5.00 0.0000 0 1 1 2.0000 2.0000 6.30

    LDF7-50A(1-5/8'')

    C No Ar (CaAa) 280.00 - 5.00 0.0000 -0.025 6 3 0.5000 1.9800 0.82

    LDF6-50A(1-1/4'')

    C No Ar (CaAa) 280.00 - 5.00 0.0000 0 2 1 0.5000 1.5500 0.66

    LDF2-50A(3/8'')

    C No Ar (CaAa) 280.00 - 5.00 1.0000 0.01 1 1 0.0000 0.4400 0.08

    RLSS 8AWG DC(3/4'')

    C No Ar (CaAa) 280.00 - 5.00 0.0000 0.01 1 1 0.5000 0.7350 0.49

    *** ***

    AL5-50(7/8'') C No Ar (CaAa) 200.00 - 5.00 0.0000 0.03 1 1 0.5000 1.1000 0.26 ***

    Feed Line/Linear Appurtenances - Entered As Area

    Description Face or

    Leg

    Allow Shield

    Component Type

    Placement

    ft

    Total Number

    CAAA

    ft2/ft

    Weight

    plf *** ***

    Feed Line/Linear Appurtenances Section Areas Tower Section

    Tower Elevation

    ft

    Face AR

    ft2

    AF

    ft2

    CAAA In Face

    ft2

    CAAA Out Face

    ft2

    Weight

    K T1 298.00-296.67 A

    B C

    0.000 0.000 0.000

    0.000 0.000 0.000

    0.000 0.605 0.000

    0.000 0.000 0.000

    0.00 0.01 0.00

    T2 296.67-293.33 A B C

    0.000 0.000 0.000

    0.000 0.000 0.000

    2.096 1.514 0.000

    0.000 0.000 0.000

    0.02 0.03 0.00

    T3 293.33-286.67 A B

    0.000 0.000

    0.000 0.000

    5.242 3.028

    0.000 0.000

    0.05 0.05

    Reviewed For Code Compliance

  • ttnnxxTToowweerr Job ATA-Sea Trail (478-122), 110028-A Page

    10 of 32

    FDH Velocitel 6521 Meridien Drive, Suite 107

    Project 17PVVN1400

    Date 13:35:27 02/09/17

    Raleigh, North Carolina 27616 Phone: (919) 755-1012 FAX: (919) 755-1031

    Client High Performance Services LLC

    Designed by AVago

    Tower Section

    Tower Elevation

    ft

    Face AR

    ft2

    AF

    ft2

    CAAA In Face

    ft2

    CAAA Out Face

    ft2

    Weight

    K C 0.000 0.000 0.000 0.000 0.00

    T4 286.67-280.00 A B C

    0.000 0.000 0.000

    0.000 0.000 0.000

    5.242 3.028 0.000

    0.000 0.000 0.000

    0.05 0.05 0.00

    T5 280.00-260.00 A B C

    0.000 0.000 0.000

    0.000 0.000 0.000

    15.727 9.083

    38.977

    0.000 0.000 0.000

    0.15 0.16 0.26

    T6 260.00-240.00 A B C

    0.000 0.000 0.000

    0.000 0.000 0.000

    15.727 9.083

    38.977

    0.000 0.000 0.000

    0.15 0.16 0.26

    T7 240.00-220.00 A B C

    0.000 0.000 0.000

    0.000 0.000 0.000

    15.727 9.083

    38.977

    0.000 0.000 0.000

    0.15 0.16 0.26

    T8 220.00-200.00 A B C

    0.000 0.000 0.000

    0.000 0.000 0.000

    15.727 9.083

    38.977

    0.000 0.000 0.000

    0.15 0.16 0.26

    T9 200.00-180.00 A B C

    0.000 0.000 0.000

    0.000 0.000 0.000

    15.727 9.083

    41.177

    0.000 0.000 0.000

    0.15 0.16 0.27

    T10 180.00-160.00 A B C

    0.000 0.000 0.000

    0.000 0.000 0.000

    15.727 9.083

    41.177

    0.000 0.000 0.000

    0.15 0.16 0.27

    T11 160.00-140.00 A B C

    0.000 0.000 0.000

    0.000 0.000 0.000

    15.727 9.083

    41.177

    0.000 0.000 0.000

    0.15 0.16 0.27

    T12 140.00-120.00 A B C

    0.000 0.000 0.000

    0.000 0.000 0.000

    15.727 9.083

    41.177

    0.000 0.000 0.000

    0.15 0.16 0.27

    T13 120.00-100.00 A B C

    0.000 0.000 0.000

    0.000 0.000 0.000

    15.727 9.083

    41.177

    0.000 0.000 0.000

    0.15 0.16 0.27

    T14 100.00-80.00 A B C

    0.000 0.000 0.000

    0.000 0.000 0.000

    15.727 9.083

    41.177

    0.000 0.000 0.000

    0.15 0.16 0.27

    T15 80.00-60.00 A B C

    0.000 0.000 0.000

    0.000 0.000 0.000

    15.727 9.083

    41.177

    0.000 0.000 0.000

    0.15 0.16 0.27

    T16 60.00-40.00 A B C

    0.000 0.000 0.000

    0.000 0.000 0.000

    15.727 9.083

    41.177

    0.000 0.000 0.000

    0.15 0.16 0.27

    T17 40.00-20.00 A B C

    0.000 0.000 0.000

    0.000 0.000 0.000

    15.727 9.083

    41.177

    0.000 0.000 0.000

    0.15 0.16 0.27

    T18 20.00-0.00 A B C

    0.000 0.000 0.000

    0.000 0.000 0.000

    11.795 9.083

    30.883

    0.000 0.000 0.000

    0.11 0.16 0.20

    Feed Line/Linear Appurtenances Section Areas - With Ice Tower Section

    Tower Elevation

    ft

    Face or

    Leg

    Ice Thickness

    in

    AR

    ft2

    AF

    ft2

    CAAA In Face

    ft2

    CAAA Out Face

    ft2

    Weight

    K T1 298.00-296.67 A

    B C

    0.623 0.000 0.000 0.000

    0.000 0.000 0.000

    0.000 0.938 0.000

    0.000 0.000 0.000

    0.00 0.02 0.00

    T2 296.67-293.33 A B C

    0.622 0.000 0.000 0.000

    0.000 0.000 0.000

    4.397 2.344 0.000

    0.000 0.000 0.000

    0.04 0.04 0.00

    Reviewed For Code Compliance

  • ttnnxxTToowweerr Job ATA-Sea Trail (478-122), 110028-A Page

    11 of 32

    FDH Velocitel 6521 Meridien Drive, Suite 107

    Project 17PVVN1400

    Date 13:35:27 02/09/17

    Raleigh, North Carolina 27616 Phone: (919) 755-1012 FAX: (919) 755-1031

    Client High Performance Services LLC

    Designed by AVago

    Tower Section

    Tower Elevation

    ft

    Face or

    Leg

    Ice Thickness

    in

    AR

    ft2

    AF

    ft2

    CAAA In Face

    ft2

    CAAA Out Face

    ft2

    Weight

    K T3 293.33-286.67 A

    B C

    0.621 0.000 0.000 0.000

    0.000 0.000 0.000

    10.989 4.685 0.000

    0.000 0.000 0.000

    0.10 0.08 0.00

    T4 286.67-280.00 A B C

    0.620 0.000 0.000 0.000

    0.000 0.000 0.000

    10.980 4.681 0.000

    0.000 0.000 0.000

    0.10 0.08 0.00

    T5 280.00-260.00 A B C

    0.617 0.000 0.000 0.000

    0.000 0.000 0.000

    32.887 14.019 55.270

    0.000 0.000 0.000

    0.30 0.24 0.61

    T6 260.00-240.00 A B C

    0.612 0.000 0.000 0.000

    0.000 0.000 0.000

    32.805 13.981 55.148

    0.000 0.000 0.000

    0.30 0.24 0.61

    T7 240.00-220.00 A B C

    0.607 0.000 0.000 0.000

    0.000 0.000 0.000

    32.716 13.940 55.017

    0.000 0.000 0.000

    0.30 0.24 0.61

    T8 220.00-200.00 A B C

    0.602 0.000 0.000 0.000

    0.000 0.000 0.000

    32.620 13.896 54.875

    0.000 0.000 0.000

    0.30 0.23 0.61

    T9 200.00-180.00 A B C

    0.596 0.000 0.000 0.000

    0.000 0.000 0.000

    32.516 13.849 59.303

    0.000 0.000 0.000

    0.30 0.23 0.63

    T10 180.00-160.00 A B C

    0.589 0.000 0.000 0.000

    0.000 0.000 0.000

    32.401 13.796 59.107

    0.000 0.000 0.000

    0.30 0.23 0.63

    T11 160.00-140.00 A B C

    0.582 0.000 0.000 0.000

    0.000 0.000 0.000

    32.274 13.737 58.889

    0.000 0.000 0.000

    0.29 0.23 0.63

    T12 140.00-120.00 A B C

    0.573 0.000 0.000 0.000

    0.000 0.000 0.000

    32.130 13.671 58.643

    0.000 0.000 0.000

    0.29 0.23 0.62

    T13 120.00-100.00 A B C

    0.564 0.000 0.000 0.000

    0.000 0.000 0.000

    31.964 13.595 58.360

    0.000 0.000 0.000

    0.29 0.23 0.62

    T14 100.00-80.00 A B C

    0.553 0.000 0.000 0.000

    0.000 0.000 0.000

    31.770 13.505 58.026

    0.000 0.000 0.000

    0.29 0.23 0.61

    T15 80.00-60.00 A B C

    0.539 0.000 0.000 0.000

    0.000 0.000 0.000

    31.531 13.396 57.618

    0.000 0.000 0.000

    0.28 0.22 0.60

    T16 60.00-40.00 A B C

    0.521 0.000 0.000 0.000

    0.000 0.000 0.000

    31.221 13.253 57.087

    0.000 0.000 0.000

    0.28 0.22 0.59

    T17 40.00-20.00 A B C

    0.495 0.000 0.000 0.000

    0.000 0.000 0.000

    30.771 13.045 56.315

    0.000 0.000 0.000

    0.27 0.22 0.58

    T18 20.00-0.00 A B C

    0.444 0.000 0.000 0.000

    0.000 0.000 0.000

    22.409 12.633 41.087

    0.000 0.000 0.000

    0.19 0.21 0.41

    Feed Line Center of Pressure

    Section Elevation

    ft

    CPX

    in

    CPZ

    in

    CPX Ice in

    CPZ Ice in

    T1 298.00-296.67 0.9998 -0.5772 1.2491 -0.7212 T2 296.67-293.33 -0.2410 -1.2293 0.0759 -1.2763 T3 293.33-286.67 -0.4706 -1.2976 -0.1603 -1.3144

    Reviewed For Code Compliance

  • ttnnxxTToowweerr Job ATA-Sea Trail (478-122), 110028-A Page

    12 of 32

    FDH Velocitel 6521 Meridien Drive, Suite 107

    Project 17PVVN1400

    Date 13:35:27 02/09/17

    Raleigh, North Carolina 27616 Phone: (919) 755-1012 FAX: (919) 755-1031

    Client High Performance Services LLC

    Designed by AVago

    Section Elevation

    ft

    CPX

    in

    CPZ

    in

    CPX Ice in

    CPZ Ice in

    T4 286.67-280.00 -0.4127 -1.1378 -0.1519 -1.2427 T5 280.00-260.00 -0.1569 1.0495 -0.0628 0.7177 T6 260.00-240.00 -0.1715 1.1212 -0.0720 0.7876 T7 240.00-220.00 -0.2162 1.3718 -0.0940 0.9751 T8 220.00-200.00 -0.2577 1.6039 -0.1147 1.1467 T9 200.00-180.00 -0.2939 1.8699 -0.1523 1.4804

    T10 180.00-160.00 -0.3303 2.0829 -0.1743 1.6574 T11 160.00-140.00 -0.3540 2.2170 -0.1919 1.7873 T12 140.00-120.00 -0.3840 2.3924 -0.2120 1.9362 T13 120.00-100.00 -0.4068 2.5235 -0.2298 2.0562 T14 100.00-80.00 -0.4332 2.6766 -0.2507 2.1921 T15 80.00-60.00 -0.4340 2.6713 -0.2622 2.2329 T16 60.00-40.00 -0.4593 2.8186 -0.2858 2.3577 T17 40.00-20.00 -0.4824 2.9530 -0.3122 2.4646 T18 20.00-0.00 -0.1214 2.4917 0.2223 1.9115

    Shielding Factor Ka

    Tower Section

    Feed Line Record No.

    Description Feed Line Segment Elev.

    Ka No Ice

    Ka Ice

    T1 1 Safety Line 3/8 296.67 - 298.00

    0.6000 0.6000

    T1 2 Climbing Ladder 296.67 - 298.00

    0.6000 0.6000

    T2 1 Safety Line 3/8 293.33 - 296.67

    0.6000 0.6000

    T2 2 Climbing Ladder 293.33 - 296.67

    0.6000 0.6000

    T2 4 Feedline Ladder (Af) 2" 293.33 - 296.00

    0.6000 0.6000

    T2 7 LDF4-50A(1/2") 293.33 - 296.00

    0.6000 0.6000

    T2 8 LDF5-50A(7/8") 293.33 - 296.00

    0.6000 0.6000

    T3 1 Safety Line 3/8 286.67 - 293.33

    0.6000 0.6000

    T3 2 Climbing Ladder 286.67 - 293.33

    0.6000 0.6000

    T3 4 Feedline Ladder (Af) 2" 286.67 - 293.33

    0.6000 0.6000

    T3 7 LDF4-50A(1/2") 286.67 - 293.33

    0.6000 0.6000

    T3 8 LDF5-50A(7/8") 286.67 - 293.33

    0.6000 0.6000

    T4 1 Safety Line 3/8 280.00 - 286.67

    0.6000 0.6000

    T4 2 Climbing Ladder 280.00 - 286.67

    0.6000 0.6000

    T4 4 Feedline Ladder (Af) 2" 280.00 - 286.67

    0.6000 0.6000

    T4 7 LDF4-50A(1/2") 280.00 - 286.67

    0.6000 0.6000

    T4 8 LDF5-50A(7/8") 280.00 - 286.67

    0.6000 0.6000

    T5 1 Safety Line 3/8 260.00 - 0.6000 0.6000

    Reviewed For Code Compliance

  • ttnnxxTToowweerr Job ATA-Sea Trail (478-122), 110028-A Page

    13 of 32

    FDH Velocitel 6521 Meridien Drive, Suite 107

    Project 17PVVN1400

    Date 13:35:27 02/09/17

    Raleigh, North Carolina 27616 Phone: (919) 755-1012 FAX: (919) 755-1031

    Client High Performance Services LLC

    Designed by AVago

    Tower Section

    Feed Line Record No.

    Description Feed Line Segment Elev.

    Ka No Ice

    Ka Ice

    280.00 T5 2 Climbing Ladder 260.00 -

    280.00 0.6000 0.6000

    T5 4 Feedline Ladder (Af) 2" 260.00 - 280.00

    0.6000 0.6000

    T5 7 LDF4-50A(1/2") 260.00 - 280.00

    0.6000 0.6000

    T5 8 LDF5-50A(7/8") 260.00 - 280.00

    0.6000 0.6000

    T5 10 Feedline Ladder (Af) 2" 260.00 - 280.00

    0.6000 0.6000

    T5 11 LDF7-50A(1-5/8") 260.00 - 280.00

    0.6000 0.6000

    T5 12 LDF6-50A(1-1/4") 260.00 - 280.00

    0.6000 0.6000

    T5 13 LDF2-50A(3/8") 260.00 - 280.00

    0.6000 0.6000

    T5 14 RLSS 8AWG DC(3/4") 260.00 - 280.00

    0.6000 0.6000

    T6 1 Safety Line 3/8 240.00 - 260.00

    0.6000 0.6000

    T6 2 Climbing Ladder 240.00 - 260.00

    0.6000 0.6000

    T6 4 Feedline Ladder (Af) 2" 240.00 - 260.00

    0.6000 0.6000

    T6 7 LDF4-50A(1/2") 240.00 - 260.00

    0.6000 0.6000

    T6 8 LDF5-50A(7/8") 240.00 - 260.00

    0.6000 0.6000

    T6 10 Feedline Ladder (Af) 2" 240.00 - 260.00

    0.6000 0.6000

    T6 11 LDF7-50A(1-5/8") 240.00 - 260.00

    0.6000 0.6000

    T6 12 LDF6-50A(1-1/4") 240.00 - 260.00

    0.6000 0.6000

    T6 13 LDF2-50A(3/8") 240.00 - 260.00

    0.6000 0.6000

    T6 14 RLSS 8AWG DC(3/4") 240.00 - 260.00

    0.6000 0.6000

    T7 1 Safety Line 3/8 220.00 - 240.00

    0.6000 0.6000

    T7 2 Climbing Ladder 220.00 - 240.00

    0.6000 0.6000

    T7 4 Feedline Ladder (Af) 2" 220.00 - 240.00

    0.6000 0.6000

    T7 7 LDF4-50A(1/2") 220.00 - 240.00

    0.6000 0.6000

    T7 8 LDF5-50A(7/8") 220.00 - 240.00

    0.6000 0.6000

    T7 10 Feedline Ladder (Af) 2" 220.00 - 240.00

    0.6000 0.6000

    T7 11 LDF7-50A(1-5/8") 220.00 - 240.00

    0.6000 0.6000

    T7 12 LDF6-50A(1-1/4") 220.00 - 240.00

    0.6000 0.6000

    T7 13 LDF2-50A(3/8") 220.00 - 240.00

    0.6000 0.6000

    T7 14 RLSS 8AWG DC(3/4") 220.00 - 240.00

    0.6000 0.6000

    T8 1 Safety Line 3/8 200.00 - 220.00

    0.6000 0.6000

    T8 2 Climbing Ladder 200.00 - 0.6000 0.6000

    Reviewed For Code Compliance

  • ttnnxxTToowweerr Job ATA-Sea Trail (478-122), 110028-A Page

    14 of 32

    FDH Velocitel 6521 Meridien Drive, Suite 107

    Project 17PVVN1400

    Date 13:35:27 02/09/17

    Raleigh, North Carolina 27616 Phone: (919) 755-1012 FAX: (919) 755-1031

    Client High Performance Services LLC

    Designed by AVago

    Tower Section

    Feed Line Record No.

    Description Feed Line Segment Elev.

    Ka No Ice

    Ka Ice

    220.00 T8 4 Feedline Ladder (Af) 2" 200.00 -

    220.00 0.6000 0.6000

    T8 7 LDF4-50A(1/2") 200.00 - 220.00

    0.6000 0.6000

    T8 8 LDF5-50A(7/8") 200.00 - 220.00

    0.6000 0.6000

    T8 10 Feedline Ladder (Af) 2" 200.00 - 220.00

    0.6000 0.6000

    T8 11 LDF7-50A(1-5/8") 200.00 - 220.00

    0.6000 0.6000

    T8 12 LDF6-50A(1-1/4") 200.00 - 220.00

    0.6000 0.6000

    T8 13 LDF2-50A(3/8") 200.00 - 220.00

    0.6000 0.6000

    T8 14 RLSS 8AWG DC(3/4") 200.00 - 220.00

    0.6000 0.6000

    T9 1 Safety Line 3/8 180.00 - 200.00

    0.6000 0.6000

    T9 2 Climbing Ladder 180.00 - 200.00

    0.6000 0.6000

    T9 4 Feedline Ladder (Af) 2" 180.00 - 200.00

    0.6000 0.6000

    T9 7 LDF4-50A(1/2") 180.00 - 200.00

    0.6000 0.6000

    T9 8 LDF5-50A(7/8") 180.00 - 200.00

    0.6000 0.6000

    T9 10 Feedline Ladder (Af) 2" 180.00 - 200.00

    0.6000 0.6000

    T9 11 LDF7-50A(1-5/8") 180.00 - 200.00

    0.6000 0.6000

    T9 12 LDF6-50A(1-1/4") 180.00 - 200.00

    0.6000 0.6000

    T9 13 LDF2-50A(3/8") 180.00 - 200.00

    0.6000 0.6000

    T9 14 RLSS 8AWG DC(3/4") 180.00 - 200.00

    0.6000 0.6000

    T9 17 AL5-50(7/8") 180.00 - 200.00

    0.6000 0.6000

    T10 1 Safety Line 3/8 160.00 - 180.00

    0.6000 0.6000

    T10 2 Climbing Ladder 160.00 - 180.00

    0.6000 0.6000

    T10 4 Feedline Ladder (Af) 2" 160.00 - 180.00

    0.6000 0.6000

    T10 7 LDF4-50A(1/2") 160.00 - 180.00

    0.6000 0.6000

    T10 8 LDF5-50A(7/8") 160.00 - 180.00

    0.6000 0.6000

    T10 10 Feedline Ladder (Af) 2" 160.00 - 180.00

    0.6000 0.6000

    T10 11 LDF7-50A(1-5/8") 160.00 - 180.00

    0.6000 0.6000

    T10 12 LDF6-50A(1-1/4") 160.00 - 180.00

    0.6000 0.6000

    T10 13 LDF2-50A(3/8") 160.00 - 180.00

    0.6000 0.6000

    T10 14 RLSS 8AWG DC(3/4") 160.00 - 180.00

    0.6000 0.6000

    T10 17 AL5-50(7/8") 160.00 - 180.00

    0.6000 0.6000

    T11 1 Safety Line 3/8 140.00 - 0.6000 0.6000

    Reviewed For Code Compliance

  • ttnnxxTToowweerr Job ATA-Sea Trail (478-122), 110028-A Page

    15 of 32

    FDH Velocitel 6521 Meridien Drive, Suite 107

    Project 17PVVN1400

    Date 13:35:27 02/09/17

    Raleigh, North Carolina 27616 Phone: (919) 755-1012 FAX: (919) 755-1031

    Client High Performance Services LLC

    Designed by AVago

    Tower Section

    Feed Line Record No.

    Description Feed Line Segment Elev.

    Ka No Ice

    Ka Ice

    160.00 T11 2 Climbing Ladder 140.00 -

    160.00 0.6000 0.6000

    T11 4 Feedline Ladder (Af) 2" 140.00 - 160.00

    0.6000 0.6000

    T11 7 LDF4-50A(1/2") 140.00 - 160.00

    0.6000 0.6000

    T11 8 LDF5-50A(7/8") 140.00 - 160.00

    0.6000 0.6000

    T11 10 Feedline Ladder (Af) 2" 140.00 - 160.00

    0.6000 0.6000

    T11 11 LDF7-50A(1-5/8") 140.00 - 160.00

    0.6000 0.6000

    T11 12 LDF6-50A(1-1/4") 140.00 - 160.00

    0.6000 0.6000

    T11 13 LDF2-50A(3/8") 140.00 - 160.00

    0.6000 0.6000

    T11 14 RLSS 8AWG DC(3/4") 140.00 - 160.00

    0.6000 0.6000

    T11 17 AL5-50(7/8") 140.00 - 160.00

    0.6000 0.6000

    T12 1 Safety Line 3/8 120.00 - 140.00

    0.6000 0.6000

    T12 2 Climbing Ladder 120.00 - 140.00

    0.6000 0.6000

    T12 4 Feedline Ladder (Af) 2" 120.00 - 140.00

    0.6000 0.6000

    T12 7 LDF4-50A(1/2") 120.00 - 140.00

    0.6000 0.6000

    T12 8 LDF5-50A(7/8") 120.00 - 140.00

    0.6000 0.6000

    T12 10 Feedline Ladder (Af) 2" 120.00 - 140.00

    0.6000 0.6000

    T12 11 LDF7-50A(1-5/8") 120.00 - 140.00

    0.6000 0.6000

    T12 12 LDF6-50A(1-1/4") 120.00 - 140.00

    0.6000 0.6000

    T12 13 LDF2-50A(3/8") 120.00 - 140.00

    0.6000 0.6000

    T12 14 RLSS 8AWG DC(3/4") 120.00 - 140.00

    0.6000 0.6000

    T12 17 AL5-50(7/8") 120.00 - 140.00

    0.6000 0.6000

    T13 1 Safety Line 3/8 100.00 - 120.00

    0.6000 0.6000

    T13 2 Climbing Ladder 100.00 - 120.00

    0.6000 0.6000

    T13 4 Feedline Ladder (Af) 2" 100.00 - 120.00

    0.6000 0.6000

    T13 7 LDF4-50A(1/2") 100.00 - 120.00

    0.6000 0.6000

    T13 8 LDF5-50A(7/8") 100.00 - 120.00

    0.6000 0.6000

    T13 10 Feedline Ladder (Af) 2" 100.00 - 120.00

    0.6000 0.6000

    T13 11 LDF7-50A(1-5/8") 100.00 - 120.00

    0.6000 0.6000

    T13 12 LDF6-50A(1-1/4") 100.00 - 120.00

    0.6000 0.6000

    T13 13 LDF2-50A(3/8") 100.00 - 120.00

    0.6000 0.6000

    T13 14 RLSS 8AWG DC(3/4") 100.00 - 0.6000 0.6000

    Reviewed For Code Compliance

  • ttnnxxTToowweerr Job ATA-Sea Trail (478-122), 110028-A Page

    16 of 32

    FDH Velocitel 6521 Meridien Drive, Suite 107

    Project 17PVVN1400

    Date 13:35:27 02/09/17

    Raleigh, North Carolina 27616 Phone: (919) 755-1012 FAX: (919) 755-1031

    Client High Performance Services LLC

    Designed by AVago

    Tower Section

    Feed Line Record No.

    Description Feed Line Segment Elev.

    Ka No Ice

    Ka Ice

    120.00 T13 17 AL5-50(7/8") 100.00 -

    120.00 0.6000 0.6000

    T14 1 Safety Line 3/8 80.00 - 100.00 0.6000 0.6000 T14 2 Climbing Ladder 80.00 - 100.00 0.6000 0.6000 T14 4 Feedline Ladder (Af) 2" 80.00 - 100.00 0.6000 0.6000 T14 7 LDF4-50A(1/2") 80.00 - 100.00 0.6000 0.6000 T14 8 LDF5-50A(7/8") 80.00 - 100.00 0.6000 0.6000 T14 10 Feedline Ladder (Af) 2" 80.00 - 100.00 0.6000 0.6000 T14 11 LDF7-50A(1-5/8") 80.00 - 100.00 0.6000 0.6000 T14 12 LDF6-50A(1-1/4") 80.00 - 100.00 0.6000 0.6000 T14 13 LDF2-50A(3/8") 80.00 - 100.00 0.6000 0.6000 T14 14 RLSS 8AWG DC(3/4") 80.00 - 100.00 0.6000 0.6000 T14 17 AL5-50(7/8") 80.00 - 100.00 0.6000 0.6000 T15 1 Safety Line 3/8 60.00 - 80.00 0.6000 0.6000 T15 2 Climbing Ladder 60.00 - 80.00 0.6000 0.6000 T15 4 Feedline Ladder (Af) 2" 60.00 - 80.00 0.6000 0.6000 T15 7 LDF4-50A(1/2") 60.00 - 80.00 0.6000 0.6000 T15 8 LDF5-50A(7/8") 60.00 - 80.00 0.6000 0.6000 T15 10 Feedline Ladder (Af) 2" 60.00 - 80.00 0.6000 0.6000 T15 11 LDF7-50A(1-5/8") 60.00 - 80.00 0.6000 0.6000 T15 12 LDF6-50A(1-1/4") 60.00 - 80.00 0.6000 0.6000 T15 13 LDF2-50A(3/8") 60.00 - 80.00 0.6000 0.6000 T15 14 RLSS 8AWG DC(3/4") 60.00 - 80.00 0.6000 0.6000 T15 17 AL5-50(7/8") 60.00 - 80.00 0.6000 0.6000 T16 1 Safety Line 3/8 40.00 - 60.00 0.6000 0.6000 T16 2 Climbing Ladder 40.00 - 60.00 0.6000 0.6000 T16 4 Feedline Ladder (Af) 2" 40.00 - 60.00 0.6000 0.6000 T16 7 LDF4-50A(1/2") 40.00 - 60.00 0.6000 0.6000 T16 8 LDF5-50A(7/8") 40.00 - 60.00 0.6000 0.6000 T16 10 Feedline Ladder (Af) 2" 40.00 - 60.00 0.6000 0.6000 T16 11 LDF7-50A(1-5/8") 40.00 - 60.00 0.6000 0.6000 T16 12 LDF6-50A(1-1/4") 40.00 - 60.00 0.6000 0.6000 T16 13 LDF2-50A(3/8") 40.00 - 60.00 0.6000 0.6000 T16 14 RLSS 8AWG DC(3/4") 40.00 - 60.00 0.6000 0.6000 T16 17 AL5-50(7/8") 40.00 - 60.00 0.6000 0.6000 T17 1 Safety Line 3/8 20.00 - 40.00 0.6000 0.6000 T17 2 Climbing Ladder 20.00 - 40.00 0.6000 0.6000 T17 4 Feedline Ladder (Af) 2" 20.00 - 40.00 0.6000 0.6000 T17 7 LDF4-50A(1/2") 20.00 - 40.00 0.6000 0.6000 T17 8 LDF5-50A(7/8") 20.00 - 40.00 0.6000 0.6000 T17 10 Feedline Ladder (Af) 2" 20.00 - 40.00 0.6000 0.6000 T17 11 LDF7-50A(1-5/8") 20.00 - 40.00 0.6000 0.6000 T17 12 LDF6-50A(1-1/4") 20.00 - 40.00 0.6000 0.6000 T17 13 LDF2-50A(3/8") 20.00 - 40.00 0.6000 0.6000 T17 14 RLSS 8AWG DC(3/4") 20.00 - 40.00 0.6000 0.6000 T17 17 AL5-50(7/8") 20.00 - 40.00 0.6000 0.6000 T18 1 Safety Line 3/8 0.00 - 20.00 0.6000 0.6000 T18 2 Climbing Ladder 0.00 - 20.00 0.6000 0.6000 T18 4 Feedline Ladder (Af) 2" 5.00 - 20.00 0.6000 0.6000 T18 7 LDF4-50A(1/2") 5.00 - 20.00 0.6000 0.6000 T18 8 LDF5-50A(7/8") 5.00 - 20.00 0.6000 0.6000 T18 10 Feedline Ladder (Af) 2" 5.00 - 20.00 0.6000 0.6000 T18 11 LDF7-50A(1-5/8") 5.00 - 20.00 0.6000 0.6000 T18 12 LDF6-50A(1-1/4") 5.00 - 20.00 0.6000 0.6000 T18 13 LDF2-50A(3/8") 5.00 - 20.00 0.6000 0.6000 T18 14 RLSS 8AWG DC(3/4") 5.00 - 20.00 0.6000 0.6000 T18 17 AL5-50(7/8") 5.00 - 20.00 0.6000 0.6000

    Reviewed For Code Compliance

  • ttnnxxTToowweerr Job ATA-Sea Trail (478-122), 110028-A Page

    17 of 32

    FDH Velocitel 6521 Meridien Drive, Suite 107

    Project 17PVVN1400

    Date 13:35:27 02/09/17

    Raleigh, North Carolina 27616 Phone: (919) 755-1012 FAX: (919) 755-1031

    Client High Performance Services LLC

    Designed by AVago

    Discrete Tower Loads

    Description Face or

    Leg

    Offset Type

    Offsets: Horz

    Lateral Vert

    ft ft ft

    Azimuth Adjustment

    °

    Placement

    ft

    CAAA Front

    ft2

    CAAA Side

    ft2

    Weight

    K

    Lightning Rod C From Leg 0.00 0.00 2.00

    0.0000 298.00 No Ice 1/2'' Ice

    0.25 0.66

    0.25 0.66

    0.01 0.01

    Beacon A From Leg 0.00 0.00 0.00

    0.0000 298.00 No Ice 1/2'' Ice

    2.00 2.50

    2.00 2.50

    0.02 0.03

    Sidemarker A From Leg 0.50 0.00 0.00

    0.0000 150.00 No Ice 1/2'' Ice

    0.38 0.63

    0.38 0.63

    0.01 0.02

    Sidemarker B From Leg 0.50 0.00 0.00

    0.0000 150.00 No Ice 1/2'' Ice

    0.38 0.63

    0.38 0.63

    0.01 0.02

    Sidemarker C From Leg 0.50 0.00 0.00

    0.0000 150.00 No Ice 1/2'' Ice

    0.38 0.63

    0.38 0.63

    0.01 0.02

    *** 741 989 w/ Mount Pipe A From Leg 4.00

    0.00 0.00

    0.0000 296.00 No Ice 1/2'' Ice

    3.37 3.78

    2.92 3.65

    0.04 0.07

    741 989 w/ Mount Pipe B From Leg 4.00 0.00 0.00

    0.0000 296.00 No Ice 1/2'' Ice

    3.37 3.78

    2.92 3.65

    0.04 0.07

    741 989 w/ Mount Pipe C From Leg 4.00 0.00 0.00

    0.0000 296.00 No Ice 1/2'' Ice

    3.37 3.78

    2.92 3.65

    0.04 0.07

    SBNHH-1D65C w/ Mount Pipe

    A From Leg 4.00 0.00 0.00

    0.0000 296.00 No Ice 1/2'' Ice

    11.61 12.35

    9.69 11.31

    0.08 0.17

    SBNHH-1D65C w/ Mount Pipe

    B From Leg 4.00 0.00 0.00

    0.0000 296.00 No Ice 1/2'' Ice

    11.61 12.35

    9.69 11.31

    0.08 0.17

    SBNHH-1D65C w/ Mount Pipe

    C From Leg 4.00 0.00 0.00

    0.0000 296.00 No Ice 1/2'' Ice

    11.61 12.35

    9.69 11.31

    0.08 0.17

    RRUS-32 B66 A From Leg 4.00 0.00 0.00

    0.0000 296.00 No Ice 1/2'' Ice

    2.74 2.96

    1.67 1.86

    0.05 0.07

    RRUS-32 B66 B From Leg 4.00 0.00 0.00

    0.0000 296.00 No Ice 1/2'' Ice

    2.74 2.96

    1.67 1.86

    0.05 0.07

    RRUS-32 B66 C From Leg 4.00 0.00 0.00

    0.0000 296.00 No Ice 1/2'' Ice

    2.74 2.96

    1.67 1.86

    0.05 0.07

    RRUS-11 A From Leg 4.00 0.00 0.00

    0.0000 296.00 No Ice 1/2'' Ice

    2.52 2.72

    1.07 1.21

    0.05 0.07

    RRUS-11 B From Leg 4.00 0.00 0.00

    0.0000 296.00 No Ice 1/2'' Ice

    2.52 2.72

    1.07 1.21

    0.05 0.07

    RRUS-11 C From Leg 4.00 0.00

    0.0000 296.00 No Ice 1/2'' Ice

    2.52 2.72

    1.07 1.21

    0.05 0.07

    Reviewed For Code Compliance

  • ttnnxxTToowweerr Job ATA-Sea Trail (478-122), 110028-A Page

    18 of 32

    FDH Velocitel 6521 Meridien Drive, Suite 107

    Project 17PVVN1400

    Date 13:35:27 02/09/17

    Raleigh, North Carolina 27616 Phone: (919) 755-1012 FAX: (919) 755-1031

    Client High Performance Services LLC

    Designed by AVago

    Description Face or

    Leg

    Offset Type

    Offsets: Horz

    Lateral Vert

    ft ft ft

    Azimuth Adjustment

    °

    Placement

    ft

    CAAA Front

    ft2

    CAAA Side

    ft2

    Weight

    K

    0.00 DC6-48-60-18-8F A From Leg 4.00

    0.00 0.00

    0.0000 296.00 No Ice 1/2'' Ice

    0.85 1.36

    0.85 1.36

    0.03 0.05

    (3) 12.5' T-Frames w/ Mods (Kenwood T1684KT12-4114)

    C None 0.0000 296.00 No Ice 1/2'' Ice

    49.30 52.20

    49.30 52.20

    2.29 2.68

    *** RRUS-11 A From Leg 4.00

    0.00 0.00

    0.0000 296.00 No Ice 1/2'' Ice

    2.52 2.72

    1.07 1.21

    0.05 0.07

    RRUS-11 B From Leg 4.00 0.00 0.00

    0.0000 296.00 No Ice 1/2'' Ice

    2.52 2.72

    1.07 1.21

    0.05 0.07

    RRUS-11 C From Leg 4.00 0.00 0.00

    0.0000 296.00 No Ice 1/2'' Ice

    2.52 2.72

    1.07 1.21

    0.05 0.07

    DC6-48-60-18-8F A From Leg 4.00 0.00 0.00

    0.0000 296.00 No Ice 1/2'' Ice

    0.85 1.36

    0.85 1.36

    0.03 0.05

    *** 741 989 w/ Mount Pipe A From Leg 4.00

    0.00 0.00

    0.0000 280.00 No Ice 1/2'' Ice

    3.37 3.78

    2.93 3.65

    0.04 0.07

    741 989 w/ Mount Pipe B From Leg 4.00 0.00 0.00

    0.0000 280.00 No Ice 1/2'' Ice

    3.37 3.78

    2.93 3.65

    0.04 0.07

    741 989 w/ Mount Pipe C From Leg 4.00 0.00 0.00

    0.0000 280.00 No Ice 1/2'' Ice

    3.37 3.78

    2.93 3.65

    0.04 0.07

    800 10309 V01 w/ Mount Pipe

    A From Leg 4.00 0.00 0.00

    0.0000 280.00 No Ice 1/2'' Ice

    8.01 8.69

    5.56 6.93

    0.05 0.11

    800 10309 V01 w/ Mount Pipe

    B From Leg 4.00 0.00 0.00

    0.0000 280.00 No Ice 1/2'' Ice

    8.01 8.69

    5.56 6.93

    0.05 0.11

    800 10309 V01 w/ Mount Pipe

    C From Leg 4.00 0.00 0.00

    0.0000 280.00 No Ice 1/2'' Ice

    8.01 8.69

    5.56 6.93

    0.05 0.11

    RRUS-11 A From Leg 4.00 0.00 0.00

    0.0000 280.00 No Ice 1/2'' Ice

    2.52 2.72

    1.07 1.21

    0.05 0.07

    RRUS-11 B From Leg 4.00 0.00 0.00

    0.0000 280.00 No Ice 1/2'' Ice

    2.52 2.72

    1.07 1.21

    0.05 0.07

    RRUS-11 C From Leg 4.00 0.00 0.00

    0.0000 280.00 No Ice 1/2'' Ice

    2.52 2.72

    1.07 1.21

    0.05 0.07

    DC6-48-60-18-8F C From Leg 4.00 0.00 0.00

    0.0000 280.00 No Ice 1/2'' Ice

    0.85 1.36

    0.85 1.36

    0.03 0.05

    (3) 10' T-Frames C None 0.0000 280.00 No Ice 1/2'' Ice

    18.73 27.19

    18.73 27.19

    0.86 1.26

    *** BCD-87010 A From Leg 6.00

    0.00 0.00

    0.0000 200.00 No Ice 1/2'' Ice

    2.62 4.05

    2.62 4.05

    0.03 0.05

    (1) Standoff A From Leg 3.00 0.0000 200.00 No Ice 0.98 3.03 0.05

    Reviewed For Code Compliance

  • ttnnxxTToowweerr Job ATA-Sea Trail (478-122), 110028-A Page

    19 of 32

    FDH Velocitel 6521 Meridien Drive, Suite 107

    Project 17PVVN1400

    Date 13:35:27 02/09/17

    Raleigh, North Carolina 27616 Phone: (919) 755-1012 FAX: (919) 755-1031

    Client High Performance Services LLC

    Designed by AVago

    Description Face or

    Leg

    Offset Type

    Offsets: Horz

    Lateral Vert

    ft ft ft

    Azimuth Adjustment

    °

    Placement

    ft

    CAAA Front

    ft2

    CAAA Side

    ft2

    Weight

    K

    0.00 0.00

    1/2'' Ice 1.70 5.22 0.08

    *** *** ***

    Load Combinations Comb.

    No. Description

    1 Dead Only 2 1.2 Dead+1.6 Wind 0 deg - No Ice 3 0.9 Dead+1.6 Wind 0 deg - No Ice 4 1.2 Dead+1.6 Wind 30 deg - No Ice 5 0.9 Dead+1.6 Wind 30 deg - No Ice 6 1.2 Dead+1.6 Wind 60 deg - No Ice 7 0.9 Dead+1.6 Wind 60 deg - No Ice 8 1.2 Dead+1.6 Wind 90 deg - No Ice 9 0.9 Dead+1.6 Wind 90 deg - No Ice

    10 1.2 Dead+1.6 Wind 120 deg - No Ice 11 0.9 Dead+1.6 Wind 120 deg - No Ice 12 1.2 Dead+1.6 Wind 150 deg - No Ice 13 0.9 Dead+1.6 Wind 150 deg - No Ice 14 1.2 Dead+1.6 Wind 180 deg - No Ice 15 0.9 Dead+1.6 Wind 180 deg - No Ice 16 1.2 Dead+1.6 Wind 210 deg - No Ice 17 0.9 Dead+1.6 Wind 210 deg - No Ice 18 1.2 Dead+1.6 Wind 240 deg - No Ice 19 0.9 Dead+1.6 Wind 240 deg - No Ice 20 1.2 Dead+1.6 Wind 270 deg - No Ice 21 0.9 Dead+1.6 Wind 270 deg - No Ice 22 1.2 Dead+1.6 Wind 300 deg - No Ice 23 0.9 Dead+1.6 Wind 300 deg - No Ice 24 1.2 Dead+1.6 Wind 330 deg - No Ice 25 0.9 Dead+1.6 Wind 330 deg - No Ice 26 1.2 Dead+1.0 Ice+1.0 Temp 27 1.2 Dead+1.0 Wind 0 deg+1.0 Ice+1.0 Temp 28 1.2 Dead+1.0 Wind 30 deg+1.0 Ice+1.0 Temp 29 1.2 Dead+1.0 Wind 60 deg+1.0 Ice+1.0 Temp 30 1.2 Dead+1.0 Wind 90 deg+1.0 Ice+1.0 Temp 31 1.2 Dead+1.0 Wind 120 deg+1.0 Ice+1.0 Temp 32 1.2 Dead+1.0 Wind 150 deg+1.0 Ice+1.0 Temp 33 1.2 Dead+1.0 Wind 180 deg+1.0 Ice+1.0 Temp 34 1.2 Dead+1.0 Wind 210 deg+1.0 Ice+1.0 Temp 35 1.2 Dead+1.0 Wind 240 deg+1.0 Ice+1.0 Temp 36 1.2 Dead+1.0 Wind 270 deg+1.0 Ice+1.0 Temp 37 1.2 Dead+1.0 Wind 300 deg+1.0 Ice+1.0 Temp 38 1.2 Dead+1.0 Wind 330 deg+1.0 Ice+1.0 Temp 39 Dead+Wind 0 deg - Service 40 Dead+Wind 30 deg - Service 41 Dead+Wind 60 deg - Service

    Reviewed For Code Compliance

  • ttnnxxTToowweerr Job ATA-Sea Trail (478-122), 110028-A Page

    20 of 32

    FDH Velocitel 6521 Meridien Drive, Suite 107

    Project 17PVVN1400

    Date 13:35:27 02/09/17

    Raleigh, North Carolina 27616 Phone: (919) 755-1012 FAX: (919) 755-1031

    Client High Performance Services LLC

    Designed by AVago

    Comb. No.

    Description

    42 Dead+Wind 90 deg - Service 43 Dead+Wind 120 deg - Service 44 Dead+Wind 150 deg - Service 45 Dead+Wind 180 deg - Service 46 Dead+Wind 210 deg - Service 47 Dead+Wind 240 deg - Service 48 Dead+Wind 270 deg - Service 49 Dead+Wind 300 deg - Service 50 Dead+Wind 330 deg - Service

    Maximum Tower Deflections - Service Wind

    Section No.

    Elevation

    ft

    Horz. Deflection

    in

    Gov. Load

    Comb.

    Tilt °

    Twist °

    T1 298 - 296.667 6.471 43 0.2661 0.0090 T2 296.667 - 293.334 6.398 43 0.2661 0.0090 T3 293.334 - 286.667 6.211 43 0.2655 0.0066 T4 286.667 - 280 5.839 43 0.2602 0.0053 T5 280 - 260 5.477 43 0.2488 0.0043 T6 260 - 240 4.469 43 0.2163 0.0021 T7 240 - 220 3.633 43 0.1781 0.0020 T8 220 - 200 2.936 43 0.1500 0.0018 T9 200 - 180 2.346 43 0.1256 0.0014

    T10 180 - 160 1.847 43 0.1066 0.0017 T11 160 - 140 1.422 43 0.0896 0.0017 T12 140 - 120 1.065 43 0.0741 0.0016 T13 120 - 100 0.772 43 0.0599 0.0014 T14 100 - 80 0.533 43 0.0469 0.0012 T15 80 - 60 0.346 43 0.0362 0.0009 T16 60 - 40 0.204 43 0.0258 0.0007 T17 40 - 20 0.100 43 0.0165 0.0004 T18 20 - 0 0.029 47 0.0082 0.0002

    Critical Deflections and Radius of Curvature - Service Wind

    Elevation

    ft

    Appurtenance Gov. Load

    Comb.

    Deflection

    in

    Tilt °

    Twist °

    Radius of Curvature

    ft 298.00 Lightning Rod 43 6.471 0.2661 0.0090 484523 296.00 741 989 w/ Mount Pipe 43 6.361 0.2661 0.0087 484523 280.00 741 989 w/ Mount Pipe 43 5.477 0.2488 0.0043 50964 200.00 BCD-87010 43 2.346 0.1256 0.0014 51889 150.00 Sidemarker 43 1.235 0.0816 0.0016 72391

    Maximum Tower Deflections - Design Wind

    Section No.

    Elevation

    ft

    Horz. Deflection

    in

    Gov. Load

    Comb.

    Tilt °

    Twist °

    T1 298 - 296.667 52.470 10 2.1503 0.0567

    Reviewed For Code Compliance

  • ttnnxxTToowweerr Job ATA-Sea Trail (478-122), 110028-A Page

    21 of 32

    FDH Velocitel 6521 Meridien Drive, Suite 107

    Project 17PVVN1400

    Date 13:35:27 02/09/17

    Raleigh, North Carolina 27616 Phone: (919) 755-1012 FAX: (919) 755-1031

    Client High Performance Services LLC

    Designed by AVago

    Section No.

    Elevation

    ft

    Horz. Deflection

    in

    Gov. Load

    Comb.

    Tilt °

    Twist °

    T2 296.667 - 293.334 51.877 10 2.1505 0.0564 T3 293.334 - 286.667 50.354 10 2.1464 0.0498 T4 286.667 - 280 47.331 10 2.1054 0.0393 T5 280 - 260 44.396 10 2.0164 0.0321 T6 260 - 240 36.217 10 1.7538 0.0178 T7 240 - 220 29.441 10 1.4443 0.0165 T8 220 - 200 23.788 10 1.2156 0.0149 T9 200 - 180 19.005 10 1.0180 0.0116

    T10 180 - 160 14.962 10 0.8639 0.0137 T11 160 - 140 11.519 10 0.7258 0.0137 T12 140 - 120 8.629 10 0.6004 0.0127 T13 120 - 100 6.250 10 0.4854 0.0113 T14 100 - 80 4.319 10 0.3799 0.0095 T15 80 - 60 2.806 10 0.2928 0.0074 T16 60 - 40 1.655 10 0.2087 0.0055 T17 40 - 20 0.813 10 0.1337 0.0036 T18 20 - 0 0.234 18 0.0661 0.0015

    Critical Deflections and Radius of Curvature - Design Wind

    Elevation

    ft

    Appurtenance Gov. Load

    Comb.

    Deflection

    in

    Tilt °

    Twist °

    Radius of Curvature

    ft 298.00 Lightning Rod 10 52.470 2.1503 0.0567 85522 296.00 741 989 w/ Mount Pipe 10 51.576 2.1502 0.0557 85522 280.00 741 989 w/ Mount Pipe 10 44.396 2.0164 0.0321 6454 200.00 BCD-87010 10 19.005 1.0180 0.0116 6405 150.00 Sidemarker 10 10.007 0.6615 0.0132 8934

    Bolt Design Data

    Section No.

    Elevation

    ft

    Component Type

    Bolt Grade

    Bolt Size

    in

    Number Of

    Bolts

    Maximum Load per

    Bolt K

    Allowable Load

    K

    Ratio Load

    Allowable

    Allowable Ratio

    Criteria

    T4 286.667 Leg A325N 0.7500 4 10.49 29.82 0.352 1 Bolt Tension

    T5 280 Leg A325N 1.0000 4 34.95 53.01 0.659 1 Bolt Tension

    T6 260 Leg A325N 1.0000 6 32.82 53.01 0.619 1 Bolt Tension

    Diagonal A325N 0.6250 1 7.29 12.43 0.587 1 Bolt Shear

    Top Girt A325N 0.6250 1 5.12 5.00 1.024 1 Member Block Shear

    T7 240 Leg A325N>1''

    1.2500 6 41.01 72.48 0.566 1 Bolt Tension

    Diagonal A325N 0.6250 1 6.38 12.43 0.514 1 Bolt Shear

    T8 220 Leg A325N>1''

    1.2500 6 48.99 72.48 0.676 1 Bolt Tension

    Diagonal A325N 0.6250 1 7.25 12.43 0.584 1 Bolt Shear

    T9 200 Leg A325N>1''

    1.5000 6 55.80 104.37 0.535 1 Bolt Tension

    Reviewed For Code Compliance

  • ttnnxxTToowweerr Job ATA-Sea Trail (478-122), 110028-A Page

    22 of 32

    FDH Velocitel 6521 Meridien Drive, Suite 107

    Project 17PVVN1400

    Date 13:35:27 02/09/17

    Raleigh, North Carolina 27616 Phone: (919) 755-1012 FAX: (919) 755-1031

    Client High Performance Services LLC

    Designed by AVago

    Section No.

    Elevation

    ft

    Component Type

    Bolt Grade

    Bolt Size

    in

    Number Of

    Bolts

    Maximum Load per

    Bolt K

    Allowable Load

    K

    Ratio Load

    Allowable

    Allowable Ratio

    Criteria

    Diagonal A325N 0.8750 1 10.93 16.95 0.645 1 Member Block Shear Secondary

    Horizontal A325N 0.8750 1 6.27 10.67 0.588 1 Member Block Shear

    T10 180 Leg A325N>1''

    1.5000 6 64.04 104.37 0.614 1 Bolt Tension

    Diagonal A325N 0.8750 1 11.92 16.95 0.703 1 Member Block Shear Secondary

    Horizontal A325N 0.8750 1 7.27 10.67 0.681 1 Member Block Shear

    T11 160 Leg A325N>1''

    1.7500 6 72.51 142.06 0.510 1 Bolt Tension

    Diagonal A325N 1.0000 1 13.28 17.28 0.768 1 Member Block Shear Secondary

    Horizontal A325N 1.0000 1 8.32 10.92 0.761 1 Member Block Shear

    T12 140 Leg A325N>1''

    1.7500 6 81.24 142.06 0.572 1 Bolt Tension

    Diagonal A325N 1.0000 1 14.86 21.60 0.688 1 Member Block Shear Secondary

    Horizontal A325N 1.0000 1 9.41 14.56 0.646 1 Member Block Shear

    T13 120 Leg A325N>1''

    2.0000 6 90.19 185.55 0.486 1 Bolt Tension

    Diagonal A325N 1.0000 1 16.32 21.60 0.755 1 Member Block Shear Secondary

    Horizontal A325N 1.0000 1 10.55 17.28 0.610 1 Member Block Shear

    T14 100 Leg A325N>1''

    2.0000 6 97.41 185.55 0.525 1 Bolt Tension

    Diagonal A325N 1.0000 1 13.09 21.60 0.606 1 Member Block Shear Secondary

    Horizontal A325N 1.0000 1 11.52 17.28 0.667 1 Member Block Shear

    T15 80 Leg A325N>1''

    2.0000 6 104.01 185.55 0.561 1 Bolt Tension

    Diagonal A325N 1.0000 1 15.08 25.56 0.590 1 Member Bearing

    Secondary Horizontal

    A325N 1.0000 1 12.44 17.28 0.720 1 Member Block Shear T16 60 Leg A325N>1'

    ' 2.0000 6 111.04 185.55 0.598 1 Bolt Tension

    Diagonal A325N 1.0000 1 16.92 25.56 0.662 1 Member Bearing

    Secondary Horizontal

    A325N 1.0000 1 13.42 21.60 0.621 1 Member Block Shear T17 40 Leg A325N>1'

    ' 2.2500 6 118.40 234.84 0.504 1 Bolt Tension

    Diagonal A325N 1.0000 1 19.47 25.56 0.762 1 Member Bearing

    Secondary Horizontal

    A325N 1.0000 1 14.45 25.92 0.558 1 Member Block Shear T18 20 Diagonal A325N

    >1'' 1.1250 1 28.49 31.31 0.910 1 Bolt Shear

    Horizontal A325N>1''

    1.1250 1 15.13 28.82 0.525 1 Member Block Shear

    Reviewed For Code Compliance

  • ttnnxxTToowweerr Job ATA-Sea Trail (478-122), 110028-A Page

    23 of 32

    FDH Velocitel 6521 Meridien Drive, Suite 107

    Project 17PVVN1400

    Date 13:35:27 02/09/17

    Raleigh, North Carolina 27616 Phone: (919) 755-1012 FAX: (919) 755-1031

    Client High Performance Services LLC

    Designed by AVago

    Compression Checks

    Leg Design Data (Compression) Section

    No. Elevation

    ft

    Size

    L

    ft

    Lu

    ft

    Kl/r

    A

    in2

    Pu

    K

    φPn

    K

    Ratio Pu

    φPn T1 298 - 296.667 1 3/4 1.33 1.33 36.6

    K=1.00 2.4053 -0.42 98.16 0.004 1

    T2 296.667 -

    293.334 1 3/4 3.33 3.33 91.4

    K=1.00 2.4053 -5.57 58.75 0.095 1

    T3 293.334 -

    286.667 1 3/4 6.67 3.33 91.4

    K=1.00 2.4053 -23.66 58.74 0.403 1

    T4 286.667 - 280 1 3/4 6.67 3.33 91.4

    K=1.00 2.4053 -44.78 58.74 0.762 1

    T5 280 - 260 SR2 1/2 + 180 deg 3.5 OD x

    0.3 (v4.13) 20.00 3.33 68.2

    K=1.18 6.4167 -146.41 194.20 0.754 1

    T6 260 - 240 3 1/4 20.02 5.00 73.9

    K=1.00 8.2958 -206.29 250.37 0.824 1

    T7 240 - 220 3 3/4 20.02 5.00 64.1

    K=1.00 11.0447 -260.40 368.18 0.707 1

    T8 220 - 200 4 20.02 5.00 60.1

    K=1.00 12.5664 -314.35 434.40 0.724 1

    T9 200 - 180 4 1/2 20.02 5.20 55.5

    K=1.00 15.9043 -361.82 571.54 0.633 1

    T10 180 - 160 4 3/4 20.02 5.17 52.3

    K=1.00 17.7205 -419.58 652.99 0.643 1

    T11 160 - 140 5 20.02 5.15 49.5

    K=1.00 19.6350 -479.85 738.79 0.650 1

    T12 140 - 120 5 1/4 20.02 5.14 47.0

    K=1.00 21.6475 -542.94 829.01 0.655 1

    T13 120 - 100 5 1/2 20.02 5.12 44.7

    K=1.00 23.7583 -608.41 923.65 0.659 1

    T14 100 - 80 6 20.03 5.15 41.2

    K=1.00 28.2743 -664.34 1123.76 0.591 1

    T15 80 - 60 6 20.03 5.14 41.1

    K=1.00 28.2743 -717.04 1124.56 0.638 1

    T16 60 - 40 6 1/4 20.03 5.12 39.4

    K=1.00 30.6796 -773.58 1232.74 0.628 1

    T17 40 - 20 6 1/2 20.03 5.11 37.8

    K=1.00 33.1831 -833.50 1345.32 0.620 1

    T18 20 - 0 6 1/2 20.03 5.01 37.0

    K=1.00 33.1831 -872.44 1351.12 0.646 1

    1 P u / φPn controls

    Diagonal Design Data (Compression)

    Reviewed For Code Compliance

  • ttnnxxTToowweerr Job ATA-Sea Trail (478-122), 110028-A Page

    24 of 32

    FDH Velocitel 6521 Meridien Drive, Suite 107

    Project 17PVVN1400

    Date 13:35:27 02/09/17

    Raleigh, North Carolina 27616 Phone: (919) 755-1012 FAX: (919) 755-1031

    Client High Performance Services LLC

    Designed by AVago

    Section No.

    Elevation

    ft

    Size

    L

    ft

    Lu

    ft

    Kl/r

    A

    in2

    Pu

    K

    φPn

    K

    Ratio Pu

    φPn T1 298 - 296.667 1 1/8 4.22 4.06 121.3

    K=0.70 0.9940 -1.23 14.84 0.083 1