multi display manager mdm-2 - ampronix · multi display manager mdm-2 •up to 27 video inputs...
TRANSCRIPT
Multi Display Manager MDM-2
• Up to 27 video inputs
• Supports Dual-Link DVI signal input
• Simultaneously supports up to twoindependent 8 megapixel displays
• Real-time with low latency
• Hardware scaling with bilinear filter
• Customer definable screen arrangements
• Highly reliable design with redundancies & watch dog
• On-Screen administration tool & API for remote control
Overview
- MDM contains all system functionality in one unit
- Capability to collect, combine, and transmit up to 27
different video sources on up to two 8M QFHD
displays or four 4Mega pixel displays.
- Digital and analog inputs are supported.
- Customer definable size, position and scale of
sources
- Sources can be cropped on top, bottom, left or right
- Signal can be scaled by a factor of 0.1 to 10.0
- Signals can be duplicated to show the same input,
cropped or sized
- Customer definable arrangement sets that can be
easily switched via web-interface with iPad or similar
device.
- Arrangements are storable at the system as well as
external storage equipment.
- Switching between predefined arrangement sets is
less then 500ms
- 2-3 frames delay from input to display
- In critical environments, the MDM has a highly
reliable design. No hard disk is used; Redundant
Power Supply’s; and Active Watch Dog are employed
- Robust construction and material methods employed
for use in specialized Medical and Industrial
disciplines.
- Status information and Diagnostics accessible via
network.
- Customizing for OEM partners is available.
US and Canada 1.800.400.7972 International 1.949.273.8000
Modes
2x 8MP
1x 8MP and 2x 4MP independent
1x 8MP and 2x 4MP extended
4x 4MP independent
2x 4MP independent and 2x 4MP extended
2x 4MP extended and 2x 4MP extended
KMS-1 Board is necessary for KVM functionality!
Models & Options
Multi Display Manager MDM-2
Type MDM-2 5U Base MDM-2 4U Base MDM-2 LC Base
Maximal Display Resolution [MP] (Base/Max) 8 / 2x8 8 8
Number of Output Dual-Link DVI connections (Base/Max)
2 / 4 2 2
Inputs with MDI-5 input boards
Number of Input Boards (Base/Max) 2 / 3 1 / 3 1 / 2
Number of Inputs 18 / 27 9 / 27 9 / 18
Number of Digital Inputs [HDMI] [165MHz] 12 / 18 6 / 18 6 / 12
Number of Digital Inputs [DVI-I] [165MHz] 2 / 3 1 / 3 1 / 2
Number of Analog Inputs [DVI-I] [135MHz] 2 / 3 1 / 3 1 / 1
Number of Analog Inputs [VGA] [170MHz] 2 / 3 1 / 3 1 / 2
Max. Number of Pixel Horizontally MDI-5 / MDI-6 2048 / 2560 2048 / 2560 2048 / 2560
Max. Number of Pixel Vertically 2160 2160 2160
Chassis 19“ 5U 19“ 4U 19“ 4U
Redundant Power Supply yes optional optional
Non redundant Power Supply no yes yes
MDM-2 5U Only
2nd GFX Board Doubles the number of displays
2nd KMS-1 Board USB to host connection for ports 8 to 14
MDM-2 Options
MDI Input Boards (MDM-2 5U max. 3 boards; MDM-2 LC max. 2 boards; MDM-2 4U max. 1 board)
Additional MDI-5 Board Additional 1x digital Single Link DVI-I, 6x HDMI, 1x analogue DVI-I and 1x analogue VGA input.
Additional MDI-6 Board Additional 1x digital Dual-Link DVI-I, 6x HDMI and 1x analogue VGA input.
Upgrade to MDI-6 Board Replace a preconfigured MDI-5 Board with a MDI-6 Board.
Add-On Boards
KMS-1 Board 7 Port Keyboard/Mouse Switch module, USB to Host connection
PPB-S Board 7 Port 5V Power Breakout Module; provides external 5V power (Hirose)
Video over IP Option
TT-264 DVI to H.264 Converter; Extends one MDM output channel to the network
Base Configuration & Upgrades
MDM-2 5U Base
MDI Bay Upgrade • MDI-6 Board
GFX Bay Upgrade • 2nd GFX Board
Option Bay Upgrades • KMS-1 Board• 2nd KMS-1 Board• PPB Board
MDM-2 4U Base
MDI Bay Upgrades • MDI-6 Board• MDI-5 Board
Option Bay Upgrades • KMS-1 Board• PPB Board
Power Upgrade • Redundant Power Supply
MDM-2 LC Base
MDI Bay Upgrades • MDI-6 Board
• MDI-5 Board
Option Bay Upgrades • KMS-1 Board• PPB Board
Multi Display Manager MDM-2
Technical Specifications
Video Input Specifications
Video timing
Per Input Channel
H-Display Min. 320 max. 2048 Pixel
V-Display Min. 200 max. 2560 Lines
Pixel-Clock Min. 16MHz max. 140/165/70MHz
H-Blank Min. 8 pixel
V-Blank Min. 4 lines
Interlace Non interlace only, progressive
Bandwidth The aggregated maximum bandwidth of all input channel is:
Per Input Board
620MPx/s
Per System 1,500MPx/s
Video Output per Graphics board
Video output
Output resolution From no monitor to max. 250MHz pixel clock
Output Connector DVI-I dual link
Number of outputs up to 2
Other Inputs / Outputs
Networking: Ethernet 10/100/1000Mbit/s Ethernet twisted pair.
Connector RJ45
Other All other inputs/outputs should not be connected.
Power Supply
Power supply Type 5U redundant 650W 4U redundant 400W non redundant 400W
Input Voltage 100 - 264VAC 90 - 264VAC 90 - 264VAC
Input Frequency
47 - 63Hz 47 to 63Hz 47 to 63Hz
Inrush Current
15A max. @115VAC / 30A max. @230VAC
60A max. @115VAC / 80A max. @230VAC
20A max. @115VAC / 40A max. @230VAC
Isolation Input to output 1500VAC Input to output 1500VAC 4242VDC
Leakage Current
3.5mA max. 3.5mA max. <1.5mA
Input Connector
IEC320/C14 per Module IEC320/C14 per Module EC320/C14
Efficiency >80%@115VAC;>83%@230VAC
>63% / 115VAC >80%
Input Current Max. 5A@115VAC / 2.5A @ 230VAC Typ. 2.3A@115VAC / 1.6A@230VAC
Max. 8A@115VAC / 4A @ 230VAC Typ. 3A@115VAC / 1.5A@230VAC
Max. 5A@115VAC / 2.5A @ 230VAC Typ. 2.6A@115VAC / 1.3A@230VAC
Power Consumption
Typ. 370W, max. 430W Typ. 340W Typ. 300W
Power switch Power switch at the back, no other hardware power off/on switch.
Technical Specifications
MDM-2 5U
MDM-2 4U
MDM-2 LC
Dimensions Environmental Specifications
Unpackaged Operating
Temperature 5 °C according EN 60068-2-1 Temperature 40 °C according EN 60068-2-2.
Unpackaged Operating Humidity
Damp heat, 25°C, 10 to 80% RH (non condensing) according EN 60068-2-38.
Unpackaged Operating Pressure
700-1060 hPa (525 -795 mmHg) or upto 3050m (10,000ft).
Packaged Non-Operating Temperature (Storage, Transportation)
Temperature -40 °C according EN 60068-2-1 Temperature +70°C according EN 60068-2-2.
Packaged Non-Operating Humidity
+25°C 10 to 95% RH (non-condensing) according 60068-2-38.
Packaged Non-Operating Pressure
500 -1060 hPa (375 -795 mmHg) or up to 5,050m (18,000 ft).
Packaged Tests Continuous Shock
according EN 60068-2-29 and EN60721-3-2, class 2M2.
Package Drop Test according EN 24180-2.
Degree of protection
IP 20
Model MDM-2 5U MDM-2 4U MDM-2 LC
Size unpacked (WxHxD)
483x220x450mm
483x177x450mm
430x172x450mm
Weight 21kg 20kg 20kg
Size packed (WxHxD)
800x520x800mm
875x440x780mm
875x440x780mm
Weight 29kg 25kg 25kg
Electrical Safety & EMC Specifications
Electrical Safety:
Power supply according IEC60950/EN60950, UL60950
EMC: According EN55022 and EN55024.
Radiated Emissions:
IEC61000-3-2/EN61000-3-2 (Harmonic Current Emissions) IEC61000-3-3/EN61000-3-3 (Voltage Changes) CISPR 22/ EN55022 or CISPR 11/EN55011 Level B Radiated & Conducted Emissions.
FCC class A.
Immunity: IEC61000-4-2/EN61000-4-2 Level 2 (ESD) IEC61000-4-3/EN61000-4-3 Level 2 (EM Field Immunity) IEC61000-4-4/EN61000-4-4 Level 2 (Fast Transient/Burst Immunity) IEC61000-4-5/EN61000-4-5 Level 2 (Surge Immunity) IEC61000-4-6/EN61000-4-6 Level 2 (Conducted Disturbances) IEC61000-4-8/EN61000-4-8 Level 2 (Power Freq Magnetic Immunity) IEC61000-4-11/EN61000-4-11 Level 3 (Voltage Dips, Short Interrupt, Voltage Variations Immunity).
FCC class A.
Marking CE, FCC, RoHS, UL, WEEE
Functionality
Scaling Each input can be scaled independently between 0.1 and 10.0
Cropping Each input can be cropped at the top, bottom, left and right side
Number of output screens
Each input can be split into 2 output windows
Naming Each input can be named. Font, color, size and position are selectable.
Border Each input can have a border around the output window on all, 3, 2, 1, or no side with a selectable color and thickness.
Layouts More than 1000 layouts can be stored
Switching Layouts
The switching time from one layout to another is <0.4s. No still image is shown during the switch.
Technical Specifications
MDM solution in an enterprise environment.
www.ampronix.com 15 Whatney, Irvine CA 92618