MDM-2Multi Display Manager
Clinically Focused, Advanced, Easy to Experience
Hybrid OR, EP Lab, and Interventional Suite Visualization System
US and Canada 1.800.400.7972 International 1.949.273.8000
MDM-2 │ Multi Display Manager
The MDM is a mu l t i - fo rmat in te r face eng ine
conf igured for s tand-a lone or in tegrated use.
Designed for reliable operation, the MDM is clinically
focused, advanced and easy to experience.
When combined with a large format, UHD resolution
display, the MDM improves cl inical conf idence
through the simultaneous visualization of multiple
sources in their native resolution.
Improve clinical workflow through one touch, low
latency preset management. Using a tablet or touch
panel, procedure data can be instantaneously viewed
in user preferred formats.
Highlights & Clinical Benefits
Clinically Focused
Clinically Focused
Advanced
• Up to 27 v ideo inputs to improve procedure
guidance and team viewing.
• InstaView 500 Improves workflow through low
latency, fast switching of user defined presets.
• MagniZoom improves f ine detai l visualization
to enhance conspicuity and reduce eye fatigue
through up to 10X magnification.
• Realtime drag & zoom via touch panel control
improves flexiblity and workflow.
• Web-based API Developer Library simplifies integration for touch panel, tablet, web,
and smart device use.
• Easily route source video simultaneously / uniquely to one or more HD/UHD displays.
• KVM control of remote PCs such as PACS for enhanced procedure support.
• The MDM can be tailored to meet your unique needs; API, input, device control,
branding, packaging, etc.
• Critical Component Redundancy assures reliable
operation.
• Watch Dog, On-screen Admin Tools & Remote
Access to improve serviceability through network
access of status and diagnostic information.
• Hardware Scaling with Bil inear Fi lter to meet
sizing, position, scaling, and cropping preferences.
MDM-2 │ Multi Display Manager
Configuration 1
C-arm HD Camera Ultrasound PACS Vitals
RJ45
8MP Display
Configuration 2
C-arm HD Camera Ultrasound PACS Vitals
USB
8MP Display
Configuration 3
C-arm HD Camera Ultrasound PACS Vitals
Ethernet
Browser for Administration 8MP Display
MDM-2 │ Multi Display Manager
Display Modes
with 2nd GFX Board with 2nd GFX Board
8 MP 8 MP 8 MP 4 MP 4 MPDisplay 1
Display 1 Display 2 Display 3 Display 4
2x 8MP independent 1x 8MP & 2x 4MP independent
with 2nd GFX Board with 2nd GFX Board
8 MP 4 MP 4 MP 4 MP 4 MP 4 MP 4 MPDisplay 1
Display 3 Display 4 Display 1 Display 2 Display 3 Display 4
1x 8MP & 2x 4MP extended 4x 4MP independent
with 2nd GFX Board with 2nd GFX Board
4 MP 4 MP 4 MP 4 MP 4 MP 4 MP 4 MP 4 MPDisplay 1 Display 2 Display 3 Display 4 Display 3 Display 4 Display 3 Display 4
2x 4MP independent & 2x 4MP extended 2x 4MP extended & 2x 4MP extended
KMS-1 Board is necessary for KVM functionality!
MDM-2 │ Multi Display Manager
Type MDM-2 5U Base MDM-2 4U Base MDM-2 LC Base
Maximal Display Resolution [MP] (Base/Max) 8 / 2x8 8 8
Number of Output Dual-Link DVI connections (Base/Max) 2 / 4 2 2
Inputs with MDI-5 input boardsNumber of Input Boards (Base/Max) 2 / 3 1 / 3 1 / 2
Number of Inputs 18 / 27 9 / 27 9 / 18
Number of Digital Inputs [HDMI] [165MHz] 12 / 18 6 / 18 6 / 12
Number of Digital Inputs [DVI-I] [165MHz] 2 / 3 1 / 3 1 / 2
Number of Analog Inputs [DVI-I] [135MHz] 2 / 3 1 / 3 1 / 1
Number of Analog Inputs [VGA] [170MHz] 2 / 3 1 / 3 1 / 2
Max. Number of Pixel Horizontally MDI-5 / MDI-6 2048 / 2560 2048 / 2560 2048 / 2560
Max. Number of Pixel Vertically 2160 2160 2160
Chassis 19“ 5U 19“ 4U 19“ 4U
Redundant Power Supply yes optional optional
Non redundant Power Supply no yes yes
MDM-2 5U Only
2nd GFX Board Doubles the number of displays
2nd KMS-1 Board USB to host connection for ports 8 to 14
Video over IP Option
TT-264 DVI to H.264 Converter; Extends one MDM output channel to the network
MDM-2 5U Only
MDI Input Boards (MDM-2 5U max. 3 boards; MDM-2 LC max. 2 boards; MDM-2 4U max. 1 board)
Additional MDI-5 Board Additional 1x digital Single Link DVI-I, 6x HDMI, 1x analogue DVI-I and 1x analogue VGA input.
Additional MDI-6 Board Additional 1x digital Dual-Link DVI-I, 6x HDMI and 1x analogue VGA input.
Upgrade to MDI-6 Board Replace a preconfigured MDI-5 Board with a MDI-6 Board.
Add-On Boards
KMS-1 Board 7 Port Keyboard/Mouse Switch module, USB to Host connection
PPB-S Board 7 Port 5V Power Breakout Module; provides external 5V power (Hirose)
Models & Options
MDM-2 │ Multi Display Manager
Base Configuration & Upgrades
MDM-2 5U
Base
MDI Bay Upgrade
• MDI-6 Board
GFX Bay Upgrade
• 2nd GFX Board
Option Bay Upgrades• KMS-1 Board• 2nd KMS-1 Board• 5v PPB Board
MDM-2 4U
Base
MDI Bay Upgrades
• MDI-6 Board• MDI-5 Board
Option Bay Upgrades
• KMS-1 Board• 5v PPB Board
MDM-2 LC
Base
MDI Bay Upgrades
• MDI-6 Board• MDI-5 Board
Option Bay Upgrades
• KMS-1 Board• 5v PPB Board
*Limited availability
MDM-2 │ Multi Display Manager
Video Input Specifications
Video timing
Doubles the number of displays
H-Display Min. 320 max. 2048 Pixel
V-Display Min. 200 max. 2560 Lines
Pixel-Clock Min. 16MHz max. 140/165/70MHz
H-Blank Min. 8 pixel
V-Blank Min. 4 lines
Interlace Non interlace only, progressive
Bandwidth
The aggregated maximum bandwidth of all input channel is:
Per Input Board 620MPx/s
Per System 1,500MPx/s
Video Input Specifications
Power supply
Type 5U redundant 650W 4U redundant 400W non redundant 400W
Input Voltage 100 - 264VAC 90 - 264VAC 90 - 264VAC
Input Frequency 47 - 63Hz 47 to 63Hz 47 to 63Hz
Inrush Current 15A max. @115VAC / 30A max. @230VAC
60A max. @115VAC / 80A max. @230VAC
20A max. @115VAC / 40A max. @230VAC
Isolation Input to output 1500VAC Input to output 1500VAC 4242VDC
Leakage Current 3.5mA max. 3.5mA max. <1.5mA
Input Connector IEC320/C14 per Module IEC320/C14 per Module EC320/C14
Efficiency >80%@115VAC;>83%@230VAC >63% / 115VAC >80%
Input Current
Max. 5A@115VAC / 2.5A@230VACTyp. 2.3A@115VAC / 1.6A@230VAC
Max. 8A@115VAC / 4A@230VACTyp. 3A@115VAC / 1.5A@230VAC
Max. 5A@115VAC / 2.5A@230VACTyp. 2.6A@115VAC / 1.3A@230VAC
Power Consumption Typ. 370W, max. 430W Typ. 340W Typ. 300W
Powerswitch
Power switch at the back, no other hardware power off/on switch.
Other Inputs / Outputs
Networking:
Ethernet 10/100/1000Mbit/s Ethernet twisted pair.
Connector RJ45
OtherAll other inputs/outputs should not be connected.
Video Output per Graphics board
Video output
Output resolution
From no monitor to max. 250MHz pixel clock
Output Connector DVI-I dual link
Number of outputs up to 2
Technical Specifications
MDM-2 │ Multi Display Manager
Environmental Specifications
Unpackaged Operating Temperature 5 °C according EN 60068-2-1Temperature 40 °C according EN 60068-2-2.
Unpackaged Operating Humidity
Damp heat, 25°C, 10 to 80% RH (non condensing) according EN 60068-2-38.
Unpackaged Operating Pressure
700-1060 hPa (525 -795 mmHg) or up to 3050m(10,000ft).
Packaged Non-Operating Temperature
(Storage, Transportation)
Temperature -40 °C according EN 60068-2-1Temperature +70°C according EN 60068-2-2.
Packaged Non-Operating Humidity
+25°C 10 to 95% RH (non-condensing)according 60068-2-38.
Packaged Non-Operating Pressure
500 -1060 hPa (375 -795 mmHg) or up to 5,050m (18,000 ft).
Packaged Tests Continuous Shock
according EN 60068-2-29 and EN60721-3-2, class 2M2.
Package Drop Test according EN 24180-2.
Degree of protection IP 20
Dimensions
Model MDM-2 5U MDM-2 4U MDM-2 LC
Size unpacked(WxHxD) 483x220x450mm 483x177x450mm 430x172x450mm
Weight 21kg 20kg 20kg
Size packed(WxHxD) 800x540x800mm 800x460x800mm 800x460x800mm
Weight 29kg 25kg 25kg
Technical Specifications
MDM-2 5U
MDM-2 4U
MDM-2 LC
MDM-2 │ Multi Display Manager
Electrical Safety & EMC Specifications
Electrical Safety Power supply according IEC60950/EN60950, UL60950
EMC According EN55022 and EN55024.
Radiated Emissions
IEC61000-3-2/EN61000-3-2 (Harmonic Current Emissions)IEC61000-3-3/EN61000-3-3 (Voltage Changes)CISPR 22/ EN55022 or CISPR 11/EN55011 Level B Radiated& Conducted Emissions.
FCC class A.
Immunity
IEC61000-4-2/EN61000-4-2 Level 2 (ESD)IEC61000-4-3/EN61000-4-3 Level 2 (EM Field Immunity)IEC61000-4-4/EN61000-4-4 Level 2 (Fast Transient/Brst Immunity)IEC61000-4-5/EN61000-4-5 Level 2 (Surge Immunity)IEC61000-4-6/EN61000-4-6 Level 2 (Conducted Disturbances)IEC61000-4-8/EN61000-4-8 Level 2 (Power Freq Magnetic Immunity)IEC61000-4-11/EN61000-4-11 Level 3 (Voltage Dips, Short Interrupt, Voltage Variations Immunity).
FCC class A.
Marking CE, FCC, RoHS, UL, WEEE
Functionality
ScalingEach input can be scaled independently between 0.1 and 10.0
CroppingEach input can be cropped at the top, bottom, left and right side
Number of output screens
Each input can be split into 2 output windows
NamingEach input can be named. Font, color, size and position are electable.
BorderEach input can have a border around the output window on all, 3, 2, 1, or no side with a selectable color and thickness.
Layouts More than 1000 layouts can be stored
Switching Layouts
The switching time from one layout to another is <0.4s. No still image is shown during the switch.
Technical Specifications