A4900 Vibrio Mpocket guide
Basic information 4Switch on/off 5Basic control 6Basic menu 7Measurement screens 8-9Saving data from measurement screen 10Light 11Memory - Route measurement 12-13Setup 14Volume 15Proximity measurements 16-17
4 5
Basic Information
Micro USB for data transfer
IR non-contact temperature sensor
LED stroboscope
ACC ICP® - sensor input
Phones output
Top panel
Buttons
Batteries
Arrow buttons
Enter button
To open the battery lid push the hinge from the back
Switch ON/OFF
Press the Enter button to switch on the device
Firmware versionSerial numberFiltersSensor sensitivity
Press and hold the Enter button to switch off the device
6 7
Arrow buttons
Press the left Arrow buttonto select this option (ESC)
Press the right Arrow button to select this option (REP)
Arrow buttons
Basic control
> switch between the measurement modes
> select the right or left item from the menu at the bottom
> move between items (up/down) in menu
Enter button > switches the instrument on/off
> confirmes the selection
> selects the middle item from the menu at the bottom
> opens the menu
Time
Moving signal indicates running measurementBattery status
Volume
Enter button
To open the Menu press the Enter button (on any measurement screen)
Basic menu
Then press the left Arrow button to open the Menu
1.
2.
You can select the following items from the menu: 3.
to switch on the torch or the stroboscope (see page 11)
for route measurement (see page 12 - 13)
setup of speed, alarms, units, time, etc. (see page 14)
for headphones volume setup (see page 15)
back to the measurement screen
> Light
> Memory
> Volume
> Setup
> -Esc-
8 9
Measurement screens
Time signal
Overall values - RMS
Overall values - PEAK
Spectrum
Use the arrow buttons to move
between the measurement screens
RMS vibration values:10 - 1000 Hz in mm/s (ips)0.5 - 16 kHz in g
Peak vibration values (0-P):10 - 1000 Hz in mm/s (ips)0.5 - 16 kHz in g
FFT analysis of vibrations: 1 - 200 Hz in mm/s (ips) RMS
Displays the 3 maximum peaks found
Demod-Envelope value
Time signal:0.5 - 16 kHz in g
Frequency bands
Displacement
FASIT (Fault Source Identification Tool)
Temperature
RMS vibration values:0.5 - 1.5 kHz in g1.5 - 5 kHz in g5 - 16 kHz in g
Overall RMS and Peak displacement: 2 - 100 Hz in μm (mils) (see page 14 for setup)
Unbalance
Looseness
Misalignment
Temperature in degrees Celsius and Fahrenheit: less than 30°C (86°F) 30 - 45°C (86 - 113°F) 45 - 60°C (113 - 140°F) 60 - 75°C (140 - 167°F) more than 75°C (167°F)
Bearing condition
Automatic speed detection(the speed can also be set manually)
i
Temperature
Overall machine condition
10 11
Saving data from measurement screen(*available for the Vibrio M only, FASIT screen cannot be saved)
Press the Enter button on any measurement screen
Press the Enter button [SAVE]
Press the Enter button [set] to confirm
Select the address (1-250) with the Arrow buttons
Press the Enter button [ACK] to save the data
[ESC] go back to the measurement
[REP] go back to the address setting
Light
Torch
Strobo
The instrument can be used as a torch in this mode
If the speed is found, the stroboscope frequency is set automatically
The frequency can be adjusted with the Arrow buttons
To adjust the tuning step, press the Enter button to get the Strobo menu
Used memory
Press any button to switch off the Torch mode
12 13
Memory - Route measurement(*available for the Vibrio M only)
Go to MENU/MEMORY/ROUTE(see page 7)
Use the Arrow buttons to switch between the machines in route
3. Machine selection
Press the Enter button [SEL] to confirm the selection
Press the Enter button [ACK] to confirm the selection
[ESC] from the route
[BCK] go back to Machine selection
4. Machine confirmation
5. Point selection
Press the Enter button [SEL] to confirm the selection
Use the Arrow buttons to switch between the points in route
6. Point confirmation
7. Taking the measurement
Press the Enter button [MEAS] to start measuring
[UP] go back to Machine selection
[BCK] go back to Point selection
8. Saving the measurement
Measurement progress can be seen on the screen
Firstly the route must be loaded to the device from the DDS software
[ACK] save the measurement
[+>] save and move to the next point
[DEL] delete the measurement
If the temperature is defined in the route, this measurement is taken first
1. Data transfer
2. Route
i
Delete all readings
Delete all readings and route structure
View readings
14 15
Setup
Speed
Alarms
Measure
Set time
Auto
Manual
Off
Default (speed is required)
R13 (rigid, group 1 and 3)
F13 (flexible, group 1 and 3)
R24 (rigid, group 2 and 4)
F24 (flexible, group 2 and 4)
Units
Disp.val
Metric
Imperial
RMS/0-P
RMS/P-P
0-P/P-P
ISO 10 816
Adash
Setup of time and date
Volume
Confirm with the Enter button
Adjust the phones volume with the Arrow buttonsDisplacement
RTE mode Normal (black background)
Inverse (available for route only)
Connect phones to the output (3.5mm jack)
Select the Volume option from the menu
Example of the route screen when the Inverse option is used
16 17
Proximity option(*available for the Vibrio MP only)
When the device is switched on, select Prox for proximity option
Use the arrow keys to move between the measurement screens
Spectrum 200 Hz
Off route data can be saved to the memory (the route cannot be performed with the proximity measurements)
The A4900 Vibrio MP needs to be connected to a proximity sensor for proximity measurement! (The default sensor sensitivity is set to 7.87 mV/μm, 200 mV/mil)
i i
Displacement 1 - 1 000 HzDC part of signal
Proximity measurements(*available for the Vibrio MP only)
Select Metric or Imperial units
Press the Enter button for the MenuSpectrum 1 kHz or 2.5 kHz
Time signal 1 - 1 000 Hz
Speed
Speed can be detected automatically or set manually