a member of unimech group, malaysia kv / …€¦ · 16" 18" 20" 24" 40 50 65...
TRANSCRIPT
Kv / Cv DataCONCENTRIC BUTTERFLY VALVE 1 1/2" UP TO 48"
A MEMBER OF UNIMECH GROUP, MALAYSIA
PIN TYPE
1 1/2"
2"2 1/2"
3"4"5"6"8"
10"12"14"16"18"20"
24"
40506580
100125150200250300350400450500
600 60.22
41.4633.3026.0419.0615.5810.737.024.10
0.29
0.691.05
0.46
1.842.58
28"30"32"36"40"
44"48"
700750800900
1000
11001200
DN In.
Flow coefficient Kv value of the valve opening angle (°)SIZES
10°
550 22"
650 26"
1050 42"
50.62
67.2082.8394.83
108.36128.28159.79182.29200.13231.15
20°1.171.832.754.177.31
10.2416.4320.2842.6061.8475.65
103.36132.22164.56200.90239.05266.74328.75376.38430.10509.17634.24723.53794.34917.49
30°2.574.036.109.24
16.2322.7136.4761.8694.57
122.93168.02299.54293.65365.49446.17530.93592.46730.12835.95955.30
1130.901408.701607.001764.302037.90
40°4.436.98
10.5516.0828.2639.5563.58
107.93164.95239.63293.26400.63512.56637.99778.73926.79
1034.201274.301459.201667.501974.102459.202805.403079.803557.50
50°6.56
10.4615.9124.3942.9560.0896.80
164.52251.31365.35447.34611.10781.94973.38
1187.901414.001578.101943.802226.202544.303012.003752.304280.604699.205428.50
60°8.48
13.9821.6233.6659.4883.15
134.64229.51350.15540.98624.90853.60
1092.601360.301659.301976.202206.102715.303111.003556.204209.605245.105983.406568.107588.80
70°8.66
15.1925.0642.2775.75
105.63173.92299.14454.68665.14817.75
1116.801430.601782.302171.202589.302892.503553.104075.204661.005516.506876.607844.308608.809951.50
80°8.66
90°8.66
15.19 15.1925.06 25.0643.28 43.2879.66 79.66
110.41 110.41192.01 192.01348.81 348.81516.42 516.42782.69 782.69991.38 994.29
1351.70 1354.501742.90 1754.202180.70 2204.202630.60 2637.503169.40 3205.403556.90 3620.904305.70 4317.204979.30 5025.605716.90 5797.206758.80 6843.708450.50 8593.309637.20 9796.40
10561.00 10712.0012248.00 12486.00
1 1/2"
2"2 1/2"
3"4"5"6"8"
10"12"14"16"18"20"
24"
40506580
100125150200250300350400450500
600 69.61
47.9338.4930.1022.0318.0112.408.124.74
0.34
0.801.21
0.53
2.132.98
28"30"32"36"40"
44"48"
700750800900
1000
11001200
DN In.
Flow coefficient Cv value of the valve opening angle (°)SIZES
10°
550 22"
650 26"
1050 42"
58.52
77.6895.75
109.62125.26148.29184.72210.73231.35267.21
20°1.352.123.184.828.45
11.8418.9923.4449.2571.4987.45
119.48152.85190.23232.24276.34308.35380.04435.10497.20588.60733.18836.40918.261060.62
30°2.974.667.05
10.6818.7626.2542.1671.51
109.32142.11194.23265.35339.46422.51515.77613.76684.88844.02966.36
1104.331307.321628.461857.692039.532355.81
40°5.128.0712.2018.5932.6745.7273.50
124.77190.68277.01339.01463.13592.52737.52900.21
1071.371195.541473.091686.841927.632282.062842.843243.043560.254112.47
50°7.5812.0918.3928.1949.6569.45
111.90190.19290.51422.34517.13706.43903.92
1125.231373.211634.581824.282247.032573.492941.213481.874337.664948.375432.286275.35
60°9.8016.1624.9938.9168.7696.12
155.64265.31404.77625.37722.38986.76
1263.051572.511918.152284.492550.253138.893596.324110.974866.306063.346916.817592.728772.65
70°10.0117.5628.9748.8687.57
122.11201.05345.81525.61768.90945.32
1291.021653.772060.342509.912993.233343.734107.384710.935388.126377.077949.359068.019951.77
11503.93
80° 90°
50.0392.09
127.63221.96403.22596.98904.79
82
1146.04 1149.401562.57 1565.802014.79 2027.862520.893040.97
2548.063048.95
3663.83 3705.444111.78 4185.764977.39 4990.685756.07 5809.596608.74 6701.567813.17 7911.329768.78 9933.8511140.60 11324.6412208.52 12383.0714158.69 14433.82
Maximumangle(°)
10.01 10.0117.56 17.5628.97 28.97
50.0392.09
127.63221.96403.22596.98904.79
81828281818180828180
8181
8180
79787976737472686562
07/16
Note : 1.The data in the table is calculated according to the product size, the practical application of minor discrepancies.
2.The data in table 5°C - 40°C after the water pressure in front of valve under the premise 1 bar is calculated.
A MEMBER OF UNIMECH GROUP, MALAYSIA
The contents of this literature are for informative purposes only.
Arita Valve is not responsible for suitability or compatibility of
these products in relation to system requirement. For specific
requirements, consult Arita Valve or their local authorized
distributors. Arita Valve reserves the right to change or modify
product design without prior notice.
Kv / Cv DataCONCENTRIC BUTTERFLY VALVE 1" UP TO 12"PIN LESS (W/O PIN)TYPE
DN In.
Flow coefficient Cv value of the valve opening angle (°)SIZES
10° 20° 30° 40° 50° 60° 70° 80° 90°
Maximumangle(°)
1 1/2"
2"2 1/2"
3"4"5"6"8"
10"12"
40506580
100125150200250300 18.01
12.408.124.74
0.34
0.801.21
0.53
2.132.98
1.352.123.184.828.45
11.8418.9923.4449.2571.49
2.974.667.05
10.6818.7626.2542.1671.51
109.32142.11
5.128.0712.2018.5932.6745.7273.50
124.77190.68277.01
7.5812.0918.3928.1949.6569.45
111.90190.19290.51422.34
9.8016.1624.9938.9168.7696.12
155.64265.31404.77625.37
10.6619.1129.6948.8687.57
122.11201.05345.81525.61768.90
55.45101.33143.14236.17411.72621.55917.62
11.40 11.4022.52 22.9533.52 34.62
57.67106.57150.42253.37434.46665.73985.20 85
84
84
838179
32*25
1 1/4"1"
PS barMaximum Flow Velocity m/s
Up to 6
10
liquid Fluids Gaseous Fluids [at ≌ 1 bar]
16≥25
2,5
345
25303540
FLOW VELOCITY
EN 593:2009 (E) Page 14
838383
83
* 1 1/4" only for Aluminium Valve
Note : 1.The data in the table is calculated according to the product size, the practical application of minor discrepancies.
2.The data in table 5°C - 40°C after the water pressure in front of valve under the premise 1 bar is calculated.
3.No Pin valve (w/o pin) in a smaller opening angle, the valve disc in the direction of the pipeline and the
projected area of the same butterfly valve, the flow coefficient is also the same.
4.DN 350 - DN 600 no pin (w/o pin) valve flow coefficient and with pin butterfly valve are the same.
DN In.
Flow coefficient Kv value of the valve opening angle (°)SIZES
10° 20° 30° 40° 50° 60° 70° 80° 90°
1 1/2"
2"2 1/2"
3"4"5"6"8"
10"12"
32*
506580
100125150200250300 15.58
10.737.024.10
0.29
0.691.05
0.46
1.842.58
1.171.832.754.177.31
10.2416.4320.2842.6061.84
2.574.036.109.24
16.2322.7136.4761.8694.57
122.93
4.436.98
10.5516.0828.2639.5563.58
107.93164.95239.63
6.5610.4615.9124.3942.9560.0896.80
164.52251.31365.35
8.4813.9821.6233.6659.4883.15
134.64229.51350.15540.98
9.2216.5325.6842.2775.75
105.63173.92299.14454.68665.14
9.86 9.8619.48 19.8529.00 29.9547.97 49.8987.66 92.19
123.82 130.12204.30 219.18356.16 375.83537.67 575.89793.79 852.25
40
251 1/4"
1"
* 1 1/4" only for Aluminium Valve
0.130.13
0.530.53
1.171.17
2.022.02
2.972.97
3.793.79
3.813.81
3.813.81
3.813.81
0.150.15
0.610.61
1.351.35
2.342.34 3.43
3.43 4.384.38 4.40
4.40 4.404.40 4.40
4.40 6161
OP
EN
ING
DE
GR
EE (
º)
PERCENTAGE OF FLOW COEFFICIENT (%)
OPENING DEGREE AND THE PERCENTAGE OF FLOW COEFFICIENT
PIN LESS PIN
PR
ES
SU
RE
(K
pa
)
PR
ES
SU
RE
(K
pa
)
VOLUME FLOW (m³/h) VOLUME FLOW (m³/h)
DIFFERENTIAL PRESSURE AND VOLUME FLOW RATIO
A MEMBER OF UNIMECH GROUP, MALAYSIA
The contents of this literature are for informative purposes only.
Arita Valve is not responsible for suitability or compatibility of
these products in relation to system requirement. For specific
requirements, consult Arita Valve or their local authorized
distributors. Arita Valve reserves the right to change or modify
product design without prior notice.
10 20 30 40 50 60 70 80 90 100
10
20
30
40
50
60
70
80
90
10 20 30 40 50 60 70 80 90 100
10
20
30
40
50
60
70
80
90
OP
EN
ING
DE
GR
EE (
º)
PERCENTAGE OF FLOW COEFFICIENT (%)
PIN LESS PIN
1 bar = 100 Kpa
Cv = 1.156 Kv
Cv = 10⁶ /24 Av
Kv = 10⁶ /28 Av
Qv = V*A*t V = Fluid Velocity (m/s)
consult designer
A = The minimum cross sectional flowpassage area (m²) consult designer
t = Unit of time
8°-1
0°
About80°
Figure 2Figure 1 Figure 3
A MEMBER OF UNIMECH GROUP, MALAYSIA
1.Valve opening within 8° - 10° disc is not out of the seat (Figure 1) flow coefficient is zero.
2.Valve opening 0° - A° is consistent with the pin type design valve.(Open A° midline valve
reaches the maximum, A is about 80°)(Figure 2).
3.Valve opening exceeds A°, midline valve through shaft, the same projected area. (flow coefficient Kv value is unchanged) Without pin type design valve double axle and the center
of the valve disc with smaller thickness. Projected area will continue to decrease with the
4.Without pin design butterfly valve flow characteristics same with Pin type butterfly valve
from Dn350 up to DN600.
BUTTERFLY VALVE PIN TYPE FLOW COEFFICIENT - Opening Curve
1.Valve opening within 8° - 10° disc is not out of the seat (Figure 1) flow coefficient is zero.
2.Valve opening approximately 80°, the overlap (Figure 2) the maximum in the flow path
direction of projection of the disc thickest, the maximum flow coefficient to within 90° tomaintain unchanged.
BUTTERFLY VALVE PINLESS TYPE FLOW COEFFICIENT - Opening Curve
increase of the angle (Figure 3). Flow coefficient Kv value becomes larger.
Kv VALUE / FLOW SELECTION
Butterfly Valve not only can be used in the pipeline cutoff effect, or as more aspects of
regulating valve (the pipeline flow and other parameters can be adjusted medium) used.
Butterfly Valve opening angle is different, the flow coefficient will be a great different.
Kv = 0.01*Qv √ /∆PKv = FLOW COEFFICIENT (m³/h)Qv = VOLUME FLOW (m³/h)
∆P = PRESSURE DROP (Mpa) = DENSITY OF FLUID (Kg/m³)
Example 1:DN 150 pipeline
Medium : waterDifferential pressurebefore and after valve : 0.1 Mpa
Flow : 100 m³/h
Kv = 0.01*Qv √ /∆PKv = 0.01*100 m³/h √1000Kg/m³ / 0.1MpaKv = 100 m³/h
Kv Value DN 150 midline valve opening 50° can be refer to the table 96.80. When open the valvegreater then 50°(less than 90°), can meets the requirement of the pipeline flow coefficient.
Example 2:DN 125 pipeline
Medium : waterDifferential pressurebefore and after valve : 0.1 MpaValve opening : 50°
As we refer to table when the midline DN 125 valve open to 50°. Kv value 60.08.
Qv = Kv/0.01√ /∆P
Qv = 60.08 m³/h / 0.01*√1000Kg/m³ / 0.1MpaQv = 60.08 m³/h when the midline DN 125 valve open to 50°. flow reach 60.08 .m³/h
The contents of this literature are for informative purposes only.
Arita Valve is not responsible for suitability or compatibility of
these products in relation to system requirement. For specific
requirements, consult Arita Valve or their local authorized
distributors. Arita Valve reserves the right to change or modify
product design without prior notice.
A MEMBER OF UNIMECH GROUP, MALAYSIA
A MEMBER OF UNIMECH GROUP, MALAYSIAARITA is a international registered trade mark of Unimech Group, Malaysia.
www.arita-valve.cn
ARITA VALVE (TIANJIN) CO., LTD. The contents of this literature are for informative purposes only.
Arita Valve is not responsible for suitability or compatibility of
these products in relation to system requirement. For specific
requirements, consult Arita Valve or their local authorized
distributors. Arita Valve reserves the right to change or modify
product design without prior notice.
PIN / PINLESS (W/O PIN) FLOW PASSAGE AREA CALCULATION
1 2 3 4
5 6 7 8 9
No SHADOW AREA
1
FORMULA SYMBOL REMARK
Circle area D Disc diameter
2 Circle area - ellipse area a° Open angle
3 Circle area - 2 x sector area
S Sector arcC Sector lengthh Sector height
R Disc radiusb Disc center thicknessSector center angle
2√h(D-h)R-b/2D/2Consult Designer
A COS b/D
4 2X x 2YX²
a1²Y²
b1²1
a1 Ellipse short axle shaft b1 Ellipse long axle shaft
R x COS a°R
5 Shadow areaD
D x COS a°YY’
Shadow areaCast area
Small sector area refer 3
4D²
D² - D² x COS a° 4
D²4
2 x (R x S - C(R-h))
2
Cast areaCOS a°
6 Shadow area 3 - 4 - 5
Flow area 2 - 67
When the minor axis of the ellipse is equalto the valve disc center thickness, pin typedisc reaches the maximum flow coefficient. Flow coefficient reaches A point.
D/360
PIN TYPE FLOW CROSS SECTIONAL AREA CALCULATION
No
8
9
SHADOW AREA FORMULA SYMBOL REMARK
PIN LESS TYPE FLOW CROSS SECTIONAL AREA CALCULATION
Shadow area (D - L - L1)x b - D x COSa° L Disc upper shaft hub high L1 Disc lower shaft hub high
Flow area 7 8
When the minor axis of the ellipse is equalto the thickness of without pin. Pin lessdisc reaches the maximum flow coefficient.