this article and any supplementary material should be cited as follows: segil jl, controzzi m, weir...

5
This article and any supplementary material should be cited as follows: Segil JL, Controzzi M, Weir RF, Cipriani C. Comparative study of state-of-the-art myoelectric controllers for multigrasp prosthetic hands. J Rehabil Res Dev. 2014;51(9):1439–54. http://dx.doi.org/10.1682/JRRD.2014.01.0014 Slideshow Project DOI:10.1682/ JRRD.2014.01.0014JSP Comparative study of state-of-the-art myoelectric controllers for multigrasp prosthetic hands Jacob L. Segil, MS; Marco Controzzi, PhD; Richard F. ff. Weir, PhD; Christian Cipriani, PhD

Upload: noreen-barnett

Post on 18-Jan-2018

217 views

Category:

Documents


0 download

DESCRIPTION

This article and any supplementary material should be cited as follows: Segil JL, Controzzi M, Weir RF, Cipriani C. Comparative study of state-of- the-art myoelectric controllers for multigrasp prosthetic hands. J Rehabil Res Dev. 2014;51(9):1439–54. Slideshow Project DOI: /JRRD JSP Method 7 nondisabled subjects. Used Southampton Hand Assessment Procedure (SHAP) to compare effectiveness of controllers during activities of daily living using multigrasp artificial hand. Used virtual hand posture matching task to compare controllers when reproducing 6 target postures.

TRANSCRIPT

Page 1: This article and any supplementary material should be cited as follows: Segil JL, Controzzi M, Weir RF, Cipriani C. Comparative study of state-of- the-art

This article and any supplementary material should be cited as follows: Segil JL, Controzzi M, Weir RF, Cipriani C. Comparative study of state-of-the-art myoelectric controllers for multigrasp prosthetic hands. J Rehabil Res Dev. 2014;51(9):1439–54. http://dx.doi.org/10.1682/JRRD.2014.01.0014

Slideshow ProjectDOI:10.1682/JRRD.2014.01.0014JSP

Comparative study of state-of-the-art myoelectric controllers for multigrasp

prosthetic handsJacob L. Segil, MS; Marco Controzzi, PhD;

Richard F. ff. Weir, PhD; Christian Cipriani, PhD

Page 2: This article and any supplementary material should be cited as follows: Segil JL, Controzzi M, Weir RF, Cipriani C. Comparative study of state-of- the-art

This article and any supplementary material should be cited as follows: Segil JL, Controzzi M, Weir RF, Cipriani C. Comparative study of state-of-the-art myoelectric controllers for multigrasp prosthetic hands. J Rehabil Res Dev. 2014;51(9):1439–54. http://dx.doi.org/10.1682/JRRD.2014.01.0014

Slideshow ProjectDOI:10.1682/JRRD.2014.01.0014JSP

• Aim– Conduct comparative study of 2 finite state machines

and a postural control scheme using virtual and physical assessment procedures.

• Relevance– Myoelectric controller should provide intuitive and

effective human-machine interface that deciphers user intent in real-time and is robust enough to operate in daily life.

Page 3: This article and any supplementary material should be cited as follows: Segil JL, Controzzi M, Weir RF, Cipriani C. Comparative study of state-of- the-art

This article and any supplementary material should be cited as follows: Segil JL, Controzzi M, Weir RF, Cipriani C. Comparative study of state-of-the-art myoelectric controllers for multigrasp prosthetic hands. J Rehabil Res Dev. 2014;51(9):1439–54. http://dx.doi.org/10.1682/JRRD.2014.01.0014

Slideshow ProjectDOI:10.1682/JRRD.2014.01.0014JSP

Method• 7 nondisabled subjects.• Used Southampton Hand Assessment Procedure

(SHAP) to compare effectiveness of controllers during activities of daily living using multigrasp artificial hand.

• Used virtual hand posture matching task to compare controllers when reproducing 6 target postures.

Page 4: This article and any supplementary material should be cited as follows: Segil JL, Controzzi M, Weir RF, Cipriani C. Comparative study of state-of- the-art

This article and any supplementary material should be cited as follows: Segil JL, Controzzi M, Weir RF, Cipriani C. Comparative study of state-of-the-art myoelectric controllers for multigrasp prosthetic hands. J Rehabil Res Dev. 2014;51(9):1439–54. http://dx.doi.org/10.1682/JRRD.2014.01.0014

Slideshow ProjectDOI:10.1682/JRRD.2014.01.0014JSP

Results• Performance when using postural control scheme

was significantly better than when using finite state machines during physical assessment when comparing within-subject averages using SHAP % difference metric.

• Virtual assessment described significantly greater completion rates for finite state machines, but movement time tended to be faster for postural control scheme.

Page 5: This article and any supplementary material should be cited as follows: Segil JL, Controzzi M, Weir RF, Cipriani C. Comparative study of state-of- the-art

This article and any supplementary material should be cited as follows: Segil JL, Controzzi M, Weir RF, Cipriani C. Comparative study of state-of-the-art myoelectric controllers for multigrasp prosthetic hands. J Rehabil Res Dev. 2014;51(9):1439–54. http://dx.doi.org/10.1682/JRRD.2014.01.0014

Slideshow ProjectDOI:10.1682/JRRD.2014.01.0014JSP

Conclusion

• Our results substantiate that postural control schemes rival other state-of-the-art myoelectric controllers.