UltraLite™ incorporates 4” ASME B31.3 / NACE MR-01-75 3,000psi certified pipework, an API 16-C 3” 5,000psi drilling choke with hard wearing Tungsten Carbide internals and enhanced operation CV (Choke Orifice) performance curve, coupled with the latest in extremely accurate and zero field maintenance electric servo actuator. Each unit has two sealed diaphragm Pressure Transducers for data validation. The system is remote- operated from a Zone-2 Hazardous Area Human Machine Interface (HMI) touch screen. The system can be supplied with Standpipe Pressure Transducer and pump stroke counters for automated pressure control versus pump rates for CBHP (constant bottom hole pressure) control. The system can also communicate with a high-pressure coriolis meter for enhanced influx detection and alarm. The coriolis meter skid is equipped with an MPD strainer to prevent large well debris from causing damage to the coriolis meter or plugging the choke. This strainer is equipped with a differential pressure sensor that alerts an MPD operator at the HMI when the strainer may need cleaning. Automated MPD Choke System Pruitt UltraLiteMPD is a highly-capable automated choke system that delivers the same benefits of Pruitt’s flagship MPD services in a compact, lighter footprint. It offers a lower cost MPD entry point for the unconventional drilling market. The Next Step in MPD Multi-staged (modular) Fully-capable Compact Automated

Upload: others

Post on 20-Jan-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: The Next Step in MPD - Pruitt, Inc Pruitt UltraLite MPD.pdfApr 02, 2020  · MPD strainer (easy clean) is designed to protect high-pressure coriolis meters. MPD strainer screen has

UltraLite™ incorporates 4” ASME B31.3 / NACE MR-01-75 3,000psi certified pipework, an API 16-C 3” 5,000psi drilling choke with hard wearing Tungsten Carbide internals and enhanced operation CV (Choke Orifice) performance curve, coupled with the latest in extremely accurate and zero field maintenance electric servo actuator. Each unit has two sealed diaphragm Pressure Transducers for data validation. The system is remote-operated from a Zone-2 Hazardous Area Human Machine Interface (HMI) touch screen. The system can be supplied with Standpipe Pressure Transducer and pump stroke counters for automated pressure control versus pump rates for CBHP (constant bottom hole pressure) control.

The system can also communicate with a high-pressure coriolis meter for enhanced influx detection and alarm. The coriolis meter skid is equipped with an MPD strainer to prevent large well debris from causing damage to the coriolis meter or plugging the choke. This strainer is equipped with a differential pressure sensor that alerts an MPD operator at the HMI when the strainer may need cleaning.

Automated MPD Choke System

Pruitt UltraLite™ MPD is a highly-capable automated choke system that delivers the same benefits of Pruitt’s flagship MPD services in a compact, lighter footprint. It offers a lower cost MPD entry point for the unconventional drilling market.

The Next Step in MPD

• Multi-staged (modular)• Fully-capable • Compact• Automated

Page 2: The Next Step in MPD - Pruitt, Inc Pruitt UltraLite MPD.pdfApr 02, 2020  · MPD strainer (easy clean) is designed to protect high-pressure coriolis meters. MPD strainer screen has

Same field-proven choke & actuator as Pruitt MPD Modular Lite ™

Detachable control system supplied with extension cables

Custom pressure control algorithms eliminate PID tuning

Small footprint – 7ft X 3.5ft X 6.5ft

• MAWP 3,000psi• Design Temp -40 to 180 deg F• USA Class 1 / Div II Electrical System• NACE MR01-75 Compliant (Sour Service)• ASME B31.3 Piping• Dimensions L 7ft, W 3.5ft, H 4.5ft• Weight 1,980lbs / 900kgs

UltraLite™ Integrated High-Pressure Coriolis Meter & MPD Strainer

Working Pressure 3,000psi

Upstream of choke placement means less susceptible to gas break out

Meter will remain active longer than downstream coriolis meters

MPD strainer (easy clean) is designed to protect high-pressure coriolis meters. MPD strainer screen has enough space to complete most jobs and is real-time monitored by differential pressure transmitter.

DESIGN PARAMETERS

For more information:[email protected]

The Next Step in MPD

UltraLite™ Choke Manifold

• MAWP 5,000psi• Design Temp -40 to 180 Deg F• API-16C 3” Drilling Chokes

with Electric Servo Actuators• API-6A Flow Block• Integral Diaphragm Protected

Pressure Transducers

• USA Class 1 / Div II Electrical System

• NACE MR01-75 Compliant (Sour Service)

• ASME B31.3 Piping, Off-skid• Weight 4,500lbs / 2,050kgs

DESIGN PARAMETERS

Page 3: The Next Step in MPD - Pruitt, Inc Pruitt UltraLite MPD.pdfApr 02, 2020  · MPD strainer (easy clean) is designed to protect high-pressure coriolis meters. MPD strainer screen has

UltraLite™ Operator Human Machine Interface (HMI)The HMI is a 15” USA Class 1 / Div II touch screen that can be located on the rig floor. This screen gives the designated operator (driller or designate) the ability to control the choke in 3 modes.

MODE 1

MANUAL = Control of choke position only

MODE 2

AUTO = Controls to a requested pressure set point

MODE 3

AUTO + RAMP = In Auto + Ramp, the choke will control pressure based on data points entered into a Ramp Table:

Ramp on Pump Rate = Choke will hold pressure against a pressure point vs a corresponding pump rate. This will allow the driller to simply slow his pumps and the MPD choke will automatically apply pressure. Ramp on Strokes = Choke will automatically apply pressure based on the number of accumulated pump strokes. This will allow for automated displacement of different density fluids or cementing operations.

DATA TRENDING:The HMI control panel also allows the driller to monitor well and system parameters related to MPD operations. • Annular Pressure via 2 Pressure transducers• Standpipe Pressure• Flow in via Pump strokes• Choke position requested and actual

With optional meter:

• Real-time flow out• Real-time density of drilling mud• Delta flow enhanced kick detection• Drilling mud flowline temperature

Contact us today for a detailed HMI walkthrough. [email protected]

UltraLite™ RCD Components6” HYDRAULIC VALVE• 3,000psi• Full 6” bore• Hydraulic actuator with full differential opening

4 1/16” HCR VALVE• 5,000psi• Hydraulic actuator with full differential opening

PRESSURE RELIEF VALVE• Set to working pressure to protect RCD• Auto Reset• API RP-92M

Please see next page for Pruitt RCD technical specs.

The Next Step in MPD

Page 4: The Next Step in MPD - Pruitt, Inc Pruitt UltraLite MPD.pdfApr 02, 2020  · MPD strainer (easy clean) is designed to protect high-pressure coriolis meters. MPD strainer screen has

Working best under pressure.

Managed Pressure Drilling & RCD [email protected]

Single/Dual Element

Maximum Tested RPM

Maximum Tested Static PSI Rating

Maximum Dynamic PSI Rating

Pass-Thru Diameter with Bearing

Diameter without Bearing

Height Range Installed in Bowl

Recommended Applications

PRCD 3016

Single

200 RPM

3,000 PSI

2,000 PSI

7.0 inches

13.625 inches

50.1 to 59.8 inches

Managed Pressure Drilling (MPD) and high pressure

PRCD 3000

Dual

200 RPM

3,000 PSI

2,000 PSI

7.0 inches

13.625 inches

65.1 to 74.7 inches

MPD and intermediate pressure

Single

200 RPM

2,000 PSI

2,000 PSI

7.0 inches

13.625 inches

50.1 to 59.8 inches

PRCD 1509

Single

200 RPM

1,500 PSI

1,000 PSI

9.0 inches

13.625 inches

47.8 to 55.2 inches

MPD and intermediate pressure applications that utilize larger drill pipe, smaller casing sizes, and/or other drill string components

PRCD 1509D

Dual

200 RPM

1,500 PSI

1,000 PSI

9.0 inches

13.625 inches

66.1 to 73.4 inches

PRCD 500

Single

200 RPM

500 PSI

250 PSI

8.2 inches

13.625 inches

Customizable

Low pressure and surface drilling applications

PRCD 2000

• Swivel Bottom Mount Flange Available• Multiple Outlet Sizes• Forged and Welded Bowl Options with Multiple Outlets• Pruitt Fluid Containment System (LP Bowls only)• HP Bowls compatible with all PRCD Bearing Assemblies• Hydraulic Clamps with Check Valve System

AdditionalFeatures

API 16RCD Monogram

Pruitt Rotating Control Devices (RCD)Technical Specifications

March 2020