Total Energy Concepts Overview

Upload: ron-saf

Post on 20-Feb-2017

21 views

Category:

Business


2 download

TRANSCRIPT

Page 1: Tec overview power point presentation 7-18-16

Total Energy ConceptsOverview

Page 2: Tec overview power point presentation 7-18-16

2

Who is Total Energy Concepts®?TEC was founded in 2003 by Damian SmithWe have over 10,000 installations across Canada, the U.S. and MexicoWe specialize in providing our customers Full System, Facility-Wide Energy Optimization SolutionsThe TEC “Circle of Optimization” includes:

• Voltage Conditioning• Power Factor Correction• Air Conditioning/Refrigeration Optimization

− SmartCool Compressor Optimization - EndoCube/CUES Control for Walk-Ins− IceCold® Refrigeration System Optimization

• Full HVAC Control & Monitoring− Demand Controlled Ventilation (DCV)− CoolPro EM A/C Control Optimization

• Full Lighting Solutions− LED Technology− Fluorescent Retrofit Optimization− Wireless Control System for Outdoor Lighting

•TEC SYSTEM OVERVIEW

Page 3: Tec overview power point presentation 7-18-16

The V-Blox Voltage Conditioning & Power Optimization Systems

From Total Energy Concepts

Page 4: Tec overview power point presentation 7-18-16

A systematic, retrofitted approach to Optimizing and Protecting electrical equipment which results in a more efficient electrical distribution system. TEC and its Vendors/Suppliers use the highest manufacturing processes and utilizes certified engineering standards during production.

All TEC and its Vendors/Suppliers manufactured equipment and installations meet and exceed the following standards: UL listed, MET listed, ABS PDA.

The SYSTEMATIC Approach

Page 5: Tec overview power point presentation 7-18-16

VOLTAGE CONDITIONING

AND PROTECTION

Page 6: Tec overview power point presentation 7-18-16

• Voltage = Pressure• Needs to be Regulated• Plumbing is Regulated• Excess Pressure = Wasted Energy• 90% of Irregularities Generated

within the Facility’s OWN Electrical System

• Systematic Approach – Optimal!

Voltage Conditioning

Page 7: Tec overview power point presentation 7-18-16

Power Surges/Lightening Strikes are more than just high energy voltage spikes that are usually associated with thunderstorms, they can cause serious damage. A lightning strike up to 3 miles away can still cause damage.

V-Blox Voltage Conditioning System• Side Effect – Umbrella of Power Protection over

the Facility

Power Protection

Page 8: Tec overview power point presentation 7-18-16

Reduce maintenance & downtime costs, premature fluorescent failures, extended equipment life cycle

Less replacements means less waste in the landfills

Fastest Clamping Speed in the industry

15 Year Product Warranty

$25,000 downstream equipment protection per occurrence

Total Protection Equals Total Peace of Mind.

Why Should You be Optimized/Protected by V-Blox?

Page 9: Tec overview power point presentation 7-18-16

POWER OPTIMIZATION

Page 10: Tec overview power point presentation 7-18-16

What is Power Factor?The ratio of real power to apparent power as illustrated here:

What Causes Low Power Factor?Inductive load (Transformers, electric loads, line loss & lighting)

Why Should You Care To Improve Your Power Factor? • Eliminate electrical production waste, thereby increasing your facilities

load capabilities• Immediate reduction in kW which equates to lower cost and CO2 emissions• Decreased maintenance and downtime

kW

kVAR

kVA

You are Paying for a Full Glass…….

Page 11: Tec overview power point presentation 7-18-16

Improve distribution of electricity

Reduce heat and line losses

Increase voltage consistency (Normalized Pressure)

Eliminate penalties and increase energy savings

Increase capacity to add more equipment without modifying electrical grid

Complete Optimization Means Less Power for Your Utility to Provide

Why Should You Optimize with V-Blox?

Page 12: Tec overview power point presentation 7-18-16

How Does the V-Blox System Work?

Every panel is completely protected with a V-Blox VCU.

The V-Blox VCU is built with one thing in mind, capture any damaging transient surge before it harms the valuable equipment in the facility.

Power from the utility company enters the facility. The reactive energy is captured by our V-Blox PFC System and recycled.

The V-Blox PFC System is custom made to the reactive needs of your electrical equipment therefore making it completely hands-free and self-sustaining.

As a result, there is not only a significant monetary savings but also a reduction in CO2 Emissions.

THE RESULTTotal protection and complete energy optimization to ensure the facility is operating at the highest efficiency level possible.

Page 13: Tec overview power point presentation 7-18-16

Reduced maintenance costs & downtime

Extended electrical equipment life

Decreased carbon footprint

Save ENERGY, Save MONEY

Minimizes utility penalties when applicable

Increased efficiency

V-Blox Benefits & Savings

Page 14: Tec overview power point presentation 7-18-16

Smartcool Systems Inc.

Providing effective and reliable energy efficiency solutions for

HVAC-R customers around the globe.

Page 15: Tec overview power point presentation 7-18-16

What Does Smartcool Do?• Smartcool reduces the electricity usage (kWh) and

demand (kW) of air conditioning, refrigeration and heat pump systems by improving the energy efficiency of their compressors.

• Smartcool delivers cutting edge energy efficiency and cost reduction solutions for customers around the world

• The ECO3, a modular retrofit technology, can be applied in air conditioning, refrigeration and heat pumps systems

• Average payback period for customers is 18 to 36 months.

Page 16: Tec overview power point presentation 7-18-16

ECO3 Features• Reduces compressor run times

• Usage (kWh) savings averaging 15-20%

• Interfaces with existing controls

• No risk to current equipment or effect on manufacturer warranty

• Maintains temperature and humidity performance

• Two models: • Single Channel, for use with a single compressor• Dual Channel, use with two compressors cooling same controlled space

Page 17: Tec overview power point presentation 7-18-16

So…how does it work?

ECO3 VIDEOhttp://www.smartcooleco3.com/the-eco3/how-the-eco3-saves-energy

Page 18: Tec overview power point presentation 7-18-16

• Chart illustrates the percentage of energy used per drop in temperature degree.

• The last degree of pull down uses 28% of the total energy for the cycle

Background Theory

Unfortunately, this increases the mid point temperature from 7.5°C to 8°C.

Page 19: Tec overview power point presentation 7-18-16

Technology Overview• Compressor optimization dynamically adjusts the length of each

operating cycle in order to have the compressor run more often at a higher suction pressure where it is most energy efficient.

• Smartcool achieves greater energy efficiency for the compressor without allowing the compressor to short cycle and without affecting the controlled space temperature.

5

6

7

8

9

10

Degr

ees C

Time

ESM Control Conventional Control

Page 20: Tec overview power point presentation 7-18-16

What it means for you…

• One Smartcool can save 500-1500 kWh per month! On average, this is equivalent to:

• Reducing 9 tons of CO2 from the atmosphere

• Planting 45 Trees

• Reducing an SUV’s mileage by 950 miles per month

Page 21: Tec overview power point presentation 7-18-16

21

EndoCubeRetrofit Device Specifically Designed for Walk-In Coolers/Freezers

Gets installed over the Copper Temperature Probe to Simulate FOOD TEMPERATURE

Results in BETTER Temperature Control and Reduced Compressor Run Time

ONE DEGREE of Adjustment = 8% Energy Savings

•TEC SYSTEM OVERVIEW

Page 22: Tec overview power point presentation 7-18-16

22

TWO PART – Catalyst added to Refrigeration Systems

Designed to Mitigate Oil Fouling (Plaque in Arteries/Veins)• ASHRE states that in as little as 3-5 years from being NEW, Oil Fouling can contribute to up to

as much as a 30% reduction in the refrigeration cycle efficiency

Gets installed into the existing refrigeration oil/refrigerant system

Significant Savings in ALL types of HVAC Systems

Results in LESS Compressor/System Run Time

Doesn’t Interfere with Any Existing Manufacturer’s Warranties

IceCold® Video on Oil Fouling

•TEC SYSTEM OVERVIEW

Page 23: Tec overview power point presentation 7-18-16

23

DEMAND CONTROLLED VENTILATION (DCV)Building Ventilation based on Carbon Dioxide LevelsPrevious Building Codes 65 CFM/Minute Ventilation• Based on Indoor Smoking

New Building Codes – 15 CFMNobody went back to change the existing equipmentWired DCV System too costly to installTEC/Airtest – FIRST WIRLESS CO2/DCV SystemEasy to InstallWireless Configuration and MonitoringCloud Based User InterfaceUtility RebatesSubstantial Savings with Short Paybacks

•TEC SYSTEM OVERVIEW

Page 24: Tec overview power point presentation 7-18-16

24

COOLPRO EM A/C CONTROL OPTIMIZATIONOptimize HVAC Run Time – Occupied / UnoccupiedMinimize Unoccupied Energy WasteMonitor Performance and React to Maintenance ProblemsDemonstrated 15-20% Energy ReductionsSingle Cloud Based Web PortalFull HVAC Control and Optimization

•TEC SYSTEM OVERVIEW

Page 25: Tec overview power point presentation 7-18-16

25

LIGHTING SOLUTIONSFluorescent Retrofit Options – 30 to 50% Energy SavingsLED Retrofit Options – 50 to 80% Energy SavingsFuture Cost Savings – Hard Cost10 Year Parts AND Labor Warranty – Outdoor Lighting• Requires a FULL VCU Protection System to be Installed

Wireless Control for Outdoor Lighting• GPS Coordinates (True Dusk til Dawn Operation)• Verizon Wireless Cell Communication System (True Time Stamp)• No more Photo Cells (They default to ON when they fail)• No more Time Clocks (They are off by 5 minutes the first 30 days)• A TRUE “Set it and Forget it!”• Demonstrated 15-20% Energy Savings

•TEC SYSTEM OVERVIEW

Page 26: Tec overview power point presentation 7-18-16

26

Benefits with Total Energy ConceptsComplete Facility Optimization and ProtectionReduced Energy Consumption3-Year/36 Month Savings Performance Guarantee – No Strings Attached!Industries Longest Product WarrantiesReduced Maintenance and Downtime CostsExtended Equipment LifeEnergy Project Financing

• No Out of Pocket Expenses• No need to Budget NEW Money• EXAMPLE:

Existing Electrical Utility Cost (Monthly Budget Amount) $15,000.00 ($180,000 Annually)TEC Projected Monthly Energy Savings $2,250.00Projected Energy Project Finance Monthly Payment $1,500.00

NEW Monthly Utility Cost $12,750.00Energy Project Payment $1,500.00TOTA MONTHLY EXPENSE $14,250.00ORIGINAL BUDGET AMOUNT (Monthly) $15,000.00

NET INCREASE IN MONTHLY UTILITY BUDGET +$750.00 (+$9,000 Annually)

•TEC SYSTEM OVERVIEW

Page 27: Tec overview power point presentation 7-18-16

27

Thank you!Total Energy Concepts®