t24 migrating your hmi system - rockwell automation · pdf fileexample 2: wonderware intouch...

43
Copyright © 2012 Rockwell Automation, Inc. All rights reserved. Migrating Your HMI Sue Burtch – Product Specialist, FactoryTalk View SE/ME John Dirks - Product Manager, Allen Bradley PanelView Plus 6 1

Upload: lamnhan

Post on 14-Mar-2018

539 views

Category:

Documents


20 download

TRANSCRIPT

Page 1: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

Migrating Your HMI

Sue Burtch – Product Specialist, FactoryTalk View SE/MEJohn Dirks - Product Manager, Allen Bradley PanelView Plus 6

1

Page 2: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved. 2

Agenda

HMI software migrations

Migration planningMigration planning

Migrating HMI hardware

Page 3: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

Do you have a lifecycle plan?

In a 2010 study of process automation users, Automation Research Corporation (ARC) identified that 88% of these users confirmed the use of automation equipment beyond the

manufacturer’s obsolescence date. In this same study, a clear majority of users acknowledge having NO lifecycle plan.

GlobalizationInnovationProductivity Sustainability

Continuous improvement at all stages of the plant

lifecycle

Replacement parts, maintenance

Take advantage of the flexibility and

scalability of today’s platforms

Adapt to market changes, target

optimization

How to compete in the global

marketplace and make actionable

data available to the “top floor”

Make the most efficient use of resources and protect your

employees and the environment, address new

standardsRockwell Automation is committed to understanding these goals

3

Page 4: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

How can Rockwell Automation help? Product longevity and lifecycle communication

Migration-enabled technologies that endure for the long term Notification of product lifecycle status, allowing you to plan for transitions to upgraded

equipment and software Lifecycle Services assist you with technology transitions Our “self service” tools and partners help you manage your own migration activities

Phased migration path and extensive toolkit A comprehensive portfolio of upgrade and replacement options, as well as conversion

enablers (StepForward) to minimize risk and protect your investments as you transition to new technology A phased migration approach that allows you to migrate at the pace that works for you

Global Solutions and Services Project management, domain expertise, and global execution to help you optimize plant

assets, increase productivity, and improve your overall financial performance.

Long-lasting products and commitment to support throughout the lifecycle4

Page 5: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

Product Longevity and Lifecycle Communication

At Rockwell Automation, we give you notice, and we give you options.

5

Page 6: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved. 6

Agenda

HMI software migrations to consider

Migration planning

HMI software migrations

Migrating HMI hardware

Page 7: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

Visualization Solutions

7

Industrial Computers and Monitors

PanelView Plus 6 Compact

PanelView Plus 6

FactoryTalk View ME

FactoryTalk ViewPoint

FactoryTalk View SE

Page 8: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

Why migrate your HMI?

Platform evolution - operating system and PC Windows XP– MS support ends in 2014 Windows 7 is new Microsoft ‘standard’ 64-bit platform and operating systems becoming standard

Plant expansion requires move to a larger system To new product, or larger license for same product

Move to a more modern solution Want better integration with controllers Want new HMI features Connectivity to other systems

Move from a competitor product

8

Page 9: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

Benefits and costs of migration

Modern platforms offer new capabilities Better connectivity with other

systems and hardware Remote HMI operator

interfaces -FactoryTalk ViewPoint or FactoryTalk VantagePoint

Better graphics and animations

Alarming / FactoryTalk Alarms & Events

Integrated security

Cost New software Hardware platforms Engineering costs

Operator retraining It takes time to learn a new

system The benefits will be efficiency

and productivity – “operator effectiveness”

9

Page 10: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

What HMI migrations can Rockwell help with?

Competitor HMI

10

Page 11: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

Example 1: RSView32 to FactoryTalk View SE

11

Moving to new 64-bit computers RSView32 does not natively support 64-bit operating systems No plans to discontinue RSView32 However, no plan in place for this support

To take advantage of features in FactoryTalk View SE and the FactoryTalk Services Platform Redundancy for HMI Server, FactoryTalk Alarms & Events Direct reference tags Online and offline access to tags FactoryTalk Alarms & Events

Why?

Page 12: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

Example 1: RSView32 to FactoryTalk View SE

FactoryTalk View SE equivalents: Development environment

RSView32 Works FactoryTalk View Studio (Enterprise) Single station runtime system

RSView32 Runtime FactoryTalk View SE Station Distributed runtime system

RSView Active Display Server FactoryTalk View SE Server and Client

12

What FactoryTalk View SE components would I need?

Page 13: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

Example 1: RSView32 to FactoryTalk View SE

Commercial StepForward discount RSView32 Messenger to Specter Instruments Win-911 discount

Technical Rockwell Automation Knowledge Base has many AIDs to help with

migration: AID 27708: RSView32 to ViewSE Conversion Guidelines

Rockwell Automation Literature Library – project migration manual Technical Support, Rockwell Sales office and Distributor can help! License replacement - tag-based vs. screen-based

13

How can Rockwell Automation help?

Page 14: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

Example 2: Wonderware InTouch to FactoryTalk View SE

Direct integration with ControlLogix Built-in alarming with FactoryTalk Alarms and Events Online and offline access to controller tags Direct addressing of controller tags

FactoryTalk Services Platform allows sharing of data and information with other FactoryTalk installations in the plant

Single provider of sales, engineering and technical support

14

Why?

Page 15: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

Example 2: Wonderware InTouch to FactoryTalk View SE

Commercial StepForward competitor migration discount

Technical New conversion utility converts InTouch project to

FactoryTalk View SE Estimated 70-80% of project is converted Displays and tag database Supports InTouch v6.x through 10.1 Free service from Rockwell Technical Support, Rockwell Automation Sales office and Distributor

can help!

15

How can Rockwell Automation help?

Page 16: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

Competitive application conversions

Intellution / GE FIX v6.0 and 7.0 iFIX v2.5 through 5.0 Converts projects to RSView32; can then be opened in

FactoryTalk View SE

Wonderware InTouch v6.x through 10.1 Converts directly to FactoryTalk View SE XML files

Graphic display files and tag databases are converted

Scripts and ActiveX controls are not converted

Follow up work will be required to complete and verify/test conversion16

Page 17: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

Example 3: PanelBuilder32 to FactoryTalk View ME

PanelBuilder32 supports entire PanelView Standard family

PanelView Standard is Silver Series

Migrate to PanelView Plus 6, and use FactoryTalk View ME

17

Why?

Page 18: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

Example 3: PanelBuilder32 to FactoryTalk View ME

Commercial StepForward migration discount Applies to both hardware and software

Technical PanelBuilder32 application will import directly into

FactoryTalk View ME Technical Support, Rockwell Automation Sales office and Distributor

can help!

18

How can Rockwell Automation help?

Page 19: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved. 19

Agenda

HMI software migrations

Migration planning

Migrating HMI hardwareMigrating HMI hardware

Page 20: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

OVERVIEW Migrate from PanelView Plus to PanelView Plus 6

PanelView Plus 700-1500 is in Silver Series PanelView Plus 6 400-600 moving to PanelView Plus 6 in 2013 Migration Requires the Ordering of New Catalog Number

Migrate from PanelView Standard First Models Discontinued Sales in June, last Models as parts deplete

in the Fall Migrate to Appropriate Terminals PVP or PVc

Migrate from Allen-Bradley InView Spectrum Now Sells Same Unit and will Insure Future Investment

(Confidential – For Internal Use Only) Copyright © 2012 Rockwell Automation, Inc. All rights reserved. 20

Page 21: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

Visualization Solutions

21

Industrial Computers and Monitors

PanelView Plus 6 Compact

PanelView Plus 6

FactoryTalk View ME

FactoryTalk ViewPoint

FactoryTalk View SE

Page 22: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

Migration……..InView Message Displays• In Silver Series (as a Rockwell product) – announced in Nov. 2011

– End of Life : November 1, 2012– 5 year support (warranty/repair) after November 1, 2012

• Product has been transitioned to Spectrum Controls– Initial Partner offering will be same form, fit, function of existing line– Partner will invest in improved displays, Comm modules and usability

• Catalog number changes (example):Rockwell Cat # = 2706-P22RSpectrum Cat # = 2706-P22RSC

22

Page 23: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

PanelView Standard

PanelView Standard announced Silver Series in January 2011

PanelViewE (2008)PanelView 300 & Micro (June ‘12)DeviceNet Comms (June ’12)ControlNet Comms (Oct ’12)PanelView 550PanelView 600PanelView 1000

23

Page 24: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

Understanding the Product Lifecycle

Rockwell Automation has distinguished itself among suppliers by shipping many solutions for more than 30 years and supporting products for as long as 7 years after their discontinuation.

Active (extending this phase is our goal) Current, in-stock product Full support (consulting, repair, training, transactional and contract services

Silver Low inventory, support through forecasted date Well-defined migration path with incentives

Discontinued No new product; repair services available

Obsolete Product and repair services unavailable

24

Page 25: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

StepForward

Offers promotional incentives to upgrade/migrate Rockwell Automation equipment.

How it Works: Order new products Request Return Authorization Return old products (in working order) Customer is issued a credit for new products

Call your local Rockwell Automation Distributor for applicableproducts and credits.

25

Page 26: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

PanelView Standard Migration

Incentives To Migrate

Product Availability

• PanelBuilder32 Migration to FactoryTalk View ME

• Publication for migrating PanelBuilder32 Applications

2711P-AP001A

• PanelView Standard is currently in Silver Series –New Sales End in 2012

• PanelView 300 & 300 Micro• PanelView 550• PanelView 600• PanelView 1000

• PanelBuilder 32 does not support Windows 7

• IA benefits (one tag database) • PanelView Conversion Services/Training Available• FactoryTalk View Studio 4.0 (or newer) to import

PanelBuilder32 files• Migration Tools• StepForward Credits

PanelBuilder32 Migration

26

Page 27: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

PanelView Standard Migration

Incentives To Migrate

Product Availability

• PanelBuilder32 Migration to FactoryTalk View ME

• Publication for migrating PanelBuilder32 Applications

2711P-AP001A

• PanelView Standard is currently in Silver Series –New Sales End in 2012

• PanelView 300 & 300 Micro• PanelView 550• PanelView 600• PanelView 1000

• PanelBuilder 32 does not support Windows 7

• IA benefits (one tag database) • PanelView Conversion Services/Training Available• FactoryTalk View Studio 4.0 (or newer) to import

PanelBuilder32 files• Migration Tools• StepForward Credits

PanelBuilder32 Migration

27

Page 28: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

Migration options with PVc family

Recommended option is the PVc 4.3” panel 2711C-T4T

No longer available for sale

as of Jun 30, 2012

28

Page 29: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

PVe PanelView Plus 6

*PanelView Plus 6 1500 will fit in PV1400E cutout with an

adapter plate to cover stud mounting holes.

Cutout Compatible

PVP 6 1250PV 1000e PVP 6 1500*

PV 1400PV 1400e,PV 1200 -Keypad only,PV 1200e – Keypad only

Migration “kits” are available that include terminal and PVP terminal at a reduced price

29

Page 30: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

PanelView Standard to Panelview Plus Hardware Migration

PV Plus 600 KeypadPV Plus 600 Keypad/Touch

PV 550 KeypadPV 550 Keypad/Touch

PV 1000 Keypad PV 1000 Touch

PV Plus 400 PV 550 TouchPV 600 Touch

Cutout Compatible

PV Plus 600 Touch

PV Plus 6 700 KeypadPV Plus 6 700 Keypad/Touch

PV 600 KeypadPV 600 Keypad/Touch

PV Plus 6 1250 Keypad or Keypad/TouchPV Plus 6 1250 Touch

30

Page 31: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

For more information

Where can I find additional Migration information? http://www.rockwellautomation.com/solutions/migration/programs.html#visualization

32

Page 32: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

PanelView Plus 700-1500 to PanelView Plus 6 700-1500• Migration PanelView Plus 6 700 –1500 is…..

– Mechanically Compatible– Application Compatible– More Performance for Less!

• Silver Series since January 2011– End of Life: December 2012– Support (warranty/repair) via Services Group after December 31, 2012

• PanelView Plus 700 to 1500 with RIO and DNET– New Catalog Numbers to Support Installed Base– Expected EOL end of 2015

33

Page 33: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

Need to upgrade your RIO PanelView?

34 Preliminary - INTERNAL USE ONLY

PanelViewStandardPanelView Plus 6

PLC 5

• ProSoft Part Number: AN-X-AB-DHRIO• Remote I/O Adapter to Ethernet/IP HMI• Upgrade your HMIs without replacing your Control System

34

Page 34: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

PanelView Plus 6 400/ 600

PanelView Plus 6 Core 4” and 6”

PanelView Plus 6 Pro 6” Internet Explorer Office Viewers Media Player Remote Desktop

Connectivity

Cutout compatible with existing PanelView Plus 400/600

Ethernet and RS232 connections

Hardware Specifications Microsoft CE 6.0 R3 Faster processor, 800Mhz More RAM memory, 256MB SD Card for external storage

Subject to change without prior notification

Available Q1 CY2013

Subject to change without prior notification

…Synchronizing Platforms w/PanelView Plus 6 700-1500

38

Page 35: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

Cross Reference Table Example

39

1. Search old catalog number “2711P-xxxD”

2. Replace with new catalog number “2711P-xxxD8”

Page 36: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

Run-Time MER Compatibility

40

Page 37: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

PanelView Plus 6 Recent Enhancements

Added Features and Improved Usability….

v6.10.01 Enhancement (August 2011) SMTP Email ActiveX Web Browser ActiveX Control

v6.10.18 (April 2012) Screen Rotation for Panel Space Savings Logo Manager for Custom Logo Improved Configuration Menus for Web Services Upgraded VNC for Remote Connection New Terminal Full Backup/Restore Utility Email Alarms with File Attachment Support for USB Audio

41

Page 38: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

Would productivity increase by allowing your operators remote access to terminal data from another? New Server Enablement on PanelView Plus 6 700-1500 supports two VNC client connections Variety of remote connection technologies, including terminal-to-terminal communication

Enhancements via Remote Access with 2711P-RN20

Improved w/ April 2012 Firmware

Knowledgebase Note 466394 – Click Here

Technology

FTP

VNC

ViewPoint

Page 39: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

Expand Your Network Capabilitieswith the Ethernet Accessory Module

NIC2: Allows Remote Connectivity with or without going through the Plant Network. Attaches to the back of the PanelView Plus 6 Logix Module.• Ideal accessory for customers looking to expand the capabilities of their PanelView Plus

6 (700-1500) with remote connection capability• 2711P-RN20 Expected Release: Winter 2012• NOT a DLR Enabled Product

PVP6

NIC1: 192.168.1.20

NIC2: 10.10.10.20

Cell/Area ZonesManufacturing Zone

43

Page 40: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

Coming for PanelView Plus 6700-1500

Hardware redesign for displays LEDs replacing CCFLs Backwards compatible via firmware

upgrade

PanelView Plus 6 will start using LEDs in displays PVP 6 4”-6” Q1 CY2013 PVP 6 15” Q3 CY2013 PVP 6 7”-12” Following 15”

Increased Memory from 512MB to 1Gig

44

Page 41: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

PVP 6 700-1500

Jan, 2015 Jan, 2018 July, 2013 CY 2013, Q1Dec 31,2012

PanelView Timeline Overview

• Subject to change based on parts availability• Repairs services available after transition period

Old PVP 700-1500(DNET/RIO*)

PVP 6 400-600

PV Standard

Old PVP 700-1500(ENET/RS232/CNET/DH+)

Old PVP 400/600(RIO/CNET/DNET/DH+*)

Old PVP 400/600(ENET/RS232)

PVP 6 Compact

45

Page 42: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

Session Takeaways

Ask about the StepForward program to make conversions from competitors or upgrades to new HMI software less expensive

Use the application conversion utilities

Rockwell Automation services and our enormous PartnerNetwork can assist you every step of the way!

Migrate from PanelView Plus to PanelView Plus 6 PanelView Standard to PanelView Plus 6 Allen-Bradley InView to Spectrum Controls

46

Page 43: T24 Migrating Your HMI System - Rockwell Automation · PDF fileExample 2: Wonderware InTouch to FactoryTalk View SE Direct integration with ControlLogix ... Microsoft PowerPoint -

Copyright © 2012 Rockwell Automation, Inc. All rights reserved.

Thank You

47