siteline clad-wood window casement table of...
TRANSCRIPT
1
TABLE OF CONTENTS
Architectural Design Manual
August 2016
Product specifications may change without notice.
Questions? Consult JELD-WEN customer service.
SITELINE
CLAD-WOOD WINDOW
CASEMENT
DIMENSIONAL WINDOWS
Siteline clad casement windows may be specified as "dimensional", by adjusting the desired rough
opening width or height.
Siteline clad casement windows are available with left or right hand operation, or stationary
(non-venting). Operating mechanism includes corrosion resistant steel hinges and dual arm
roto-type operator with hardened steel gears and operating arms. Sash locks are concealed unison
type with an exposed locking lever and escutcheon plate. There are several interior hardware finish
options. Refer to the Specifications for finish options.
MULTIPLE ASSEMBLIES
Siteline clad casement windows may be mulled above, below,
or beside other clad casement windows, or other clad window
products.
Scale: NTS
2
GENERAL INFORMATION
Architectural Design Manual
August 2016
Product specifications may change without notice.
Questions? Consult JELD-WEN customer service.
SITELINE
CLAD-WOOD WINDOW
CASEMENT
LITE CUT OPTIONS
Special lite cut patterns can include a wide variety of straight line and radius
patterns. The illustrations shown here represent just a few of the possibilities.
Rectangular, horizontal, vertical and Prairie lite patterns are available in all standard
size clad casement windows. Uneven, diamond, radius and Gothic lite cuts are
available, subject to approval. Approvals are based on the ability to fulfill the design
requirement while maintaining the construction integrity of the finished product.
BAR ALIGNMENT
Alignment of divided lite muntin bars from one window to the
next is often required by fine architectural design. Wood
grilles, Grilles Between the Glass, grilles, and Simulated
Divided Lites may be specified with muntin bars aligned.
DIAMOND GOTHICRADIUS
RECTANGULAR
Siteline clad casement windows are available with removable grilles in 7/8", 1-1/8" and 1-3/8" widths, Airspace (
between the panes) grilles, and Simulated Divided Lites. Standard lite cuts are rectangular, and conform to the
layouts noted in the charts on the next page. To use the chart, refer to the appropriate table by the type of window
and type of bars or grilles the section drawings illustrate. Then simply cross reference the frame Height and Width
to determine the standard lite cut.
HORIZONTAL UNEVENPRAIRIE
Scale: NTS
3
LITE CUT INFORMATION
Architectural Design Manual
August 2016
Product specifications may change without notice.
Questions? Consult JELD-WEN customer service.
SITELINE
CLAD-WOOD WINDOW
CASEMENT
CASEMENT UNIT HANDING:
UNIT HANDING IS DEFINED
(FROM THE EXTERIOR) AS
THE DIRECTION THE SASH
OPENS.
RIGHT
HAND
LEFT
HAND
OPERATOR
OPERATOR
Scale: NTS
4
HANDING & OPERATION
Architectural Design Manual
August 2016
Product specifications may change without notice.
Questions? Consult JELD-WEN customer service.
SITELINE
CLAD-WOOD WINDOW
CASEMENT
Vertical exterior trim offerings with
standard sill nosing. Trim on 3 sides.
Vertical exterior trim offerings without sill
nose. Trim on all 4 sides.
Horizontal exterior trim offerings below are the
same with or without sill nose.
General Notes:
Unit size is always the maximum size of the
window with or without trim and does not
include nail fin.
Masonry Opening:
Masonry opening is always 1/2" over
(height and width) the unit size or the
outside of the trim of the window.
Rough Opening:
Rough opening is always 3/4" over frame
size of the window.
A (BM)
B (BBM)
C (AC)
D (FC)
I (B
M)
J (B
BM
)
K (A
C)
L (F
C)
E (B
M)
F (B
BM
)
G (A
C)
H (F
C)
Scale: NTS
5
UNIT SIZING, ROUGH OPENING & MASONRY OPENINGS
Architectural Design Manual
August 2016
Product specifications may change without notice.
Questions? Consult JELD-WEN customer service.
SITELINE
CLAD-WOOD WINDOW
CASEMENT
1 1/2"
1 3/4"
3"
1 5/16"
3"
1 1/4"
1 3/8"
1 1/4"
9/16"
1 1/2"
1 3/4"
5/16"
1 1/2"
1 5/16"
1 3/4"
2 1/4"
2 1/16"
1 1/16"
1"1/2"
BEADED
BRICKMOULD
BRICKMOULDSTANDARD
3 1/2" FLAT
CASING
ADAMS
CASING
STANDARD
SILL NOSE
NO SILL NOSE
1" SILL
NOSING
2" SILL
NOSING
SILL NOSE OPTIONS
Scale: 3" = 1' - 0"
6
TRIM OPTIONS
Architectural Design Manual
August 2016
Product specifications may change without notice.
Questions? Consult JELD-WEN customer service.
SITELINE
CLAD-WOOD WINDOW
CASEMENT
3/4"
1/2"
1/8"
11/16"
1/2"
1/16"
3/4"
1/2"
1/8"
1/8"1/16" 1/8"
3/4"
7/16"
1/8"
1/16"
1/8"
7/8"
1/2"
3/16"
3/16"
15/16"
7/16"
1/4"
1/4"
7/8"
1/2"
1/4"
LAM
1/8"
13/16"
3/8"
1/4" LAM
1/8"
15/16"
7/16"
1/4"
LAM
1/4"
15/16"
1/2"
1/8"
15/16"
7/16"
1/8"
5/16" LAM 5/16" LAM
15/16"
7/16"
1/8"
5/16" LAM
15/16"
1/2"
1/8"
5/16" LAM
3/4"
7/16"
3/16"
1/8"
7/8"
9/16"
3/16"
1/8"
13/16"
9/16"
1/8"
1/8"
3.9mm lites
6/4 Sash
3.1mm lites
(Tempered, Obscure, Pattern)
6/4 Sash
3.0mm lites
6/4 Sash
2.2mm lites
6/4 Sash
STC/Safety Lites
(Laminated)
6/4 Sash
STC Lites
6/4 Sash
3.1mm lites
(Tempered, Obscure, Pattern)
8/4 Sash
STC/Safety Lites
(Laminated)
8/4 Sash
STC/Safety Lites
(Laminated)
8/4 Sash
STC Lites
8/4 Sash
5.7mm lites
8/4 Sash
4.7mm lites
8/4 Sash
Impact
8/4 Sash
Impact
8/4 Sash
Impact
8/4 Sash
Impact
8/4 Sash
.030
.030
.030
.090 .090 .090 .090
Scale: 6" = 1' - 0"
7
GLAZING OPTIONS
Architectural Design Manual
August 2016
Product specifications may change without notice.
Questions? Consult JELD-WEN customer service.
SITELINE
CLAD-WOOD WINDOW
CASEMENT
TRADITIONAL CONTEMPORARY
Scale: 1' - 0" = 1' - 0"
8
GLASS STOP OPTIONS
Architectural Design Manual
August 2016
Product specifications may change without notice.
Questions? Consult JELD-WEN customer service.
SITELINE
CLAD-WOOD WINDOW
CASEMENT
4 9/16"
6 9/16"
1 1/8"
5/8"
1 3/8"
1 1/8"
5/8"
3 3/8"
7 15/16"
1 1/8"
4 3/4"
4 1/16"
1 1/8"
1 1/8"
9 5/16"
1 1/8"
5/8"
4 3/4"
1 3/8"
5/8"
7 1/4"
5/16"
3/8"
3 3/16"
3 3/16" 3 3/16"
3 3/16"
3 3/16"
4 9/16"
4 9/16" WALL
6 9/16" WALL7 15/16" WALL
5/4 JAMB THICKNESS OPTION
7 1/4" WALL
9 5/16" WALL
5/4-4/4 STACKED KERFED
JAMB OPTION
Kerfed Jamb Extension only available on 4/4 or 5/4 options
Maximum jamb length for 4/4 is 7 15/16".
Maximum jamb length for 5/4 is 7 1/4".
Maximum jamb length for 5/4 2 piece stacked is 12".
Scale: 3" = 1' - 0"
9
JAMB EXTENDER OPTIONS
Architectural Design Manual
August 2016
Product specifications may change without notice.
Questions? Consult JELD-WEN customer service.
SITELINE
CLAD-WOOD WINDOW
CASEMENT
Operating - Operating
Operating - Stationary
Stationary
Operating
Direct Set - Operating
5 15/16"
2 5/16"
5 15/16"
2 5/16"
5 15/16"
2 5/16"
4 3/4"
2 5/16"
4 3/4"
2 5/16"
Direct Set
Operating
Scale: 3" = 1' - 0"
10
MULLION OPTIONS - STANDARD
Architectural Design Manual
August 2016
Product specifications may change without notice.
Questions? Consult JELD-WEN customer service.
SITELINE
CLAD-WOOD WINDOW
CASEMENT
6 1/8"
2"
7 15/16"
1"
6 15/16"
4"
9 15/16"
1/4"
OPERATING / OPERATING
W/ 1/4" STRUCTURAL MULL
HORIZONTAL SECTION
OPERATING / OPERATING
W/ 2" SOLID SPREAD MULL
HORIZONTAL SECTION
OPERATING / OPERATING
W/ 1" SOLID SPREAD MULL
HORIZONTAL SECTION
OPERATING / OPERATING
W/ 4" SOLID SPREAD MULL
HORIZONTAL SECTION
Scale: 3" = 1' - 0"
11
MULLION OPTIONS - SPREAD
Architectural Design Manual
August 2016
Product specifications may change without notice.
Questions? Consult JELD-WEN customer service.
SITELINE
CLAD-WOOD WINDOW
CASEMENT
4"
9 7/8"
2"
7 7/8"
1"
6 7/8"
1/4"
6 3/16"
STATIONARYOPERATING
W/ 1/4" STRUCTURAL
MULL VERTICAL SECTION
STATIONARYOPERATING
W/ 1" SOLID SPREAD
MULL VERTICAL SECTION
STATIONARYOPERATING
W/ 2" SOLID SPREAD
MULL VERTICAL SECTION
STATIONARYOPERATING
W/ 4" SOLID SPREAD
MULL VERTICAL SECTION
Scale: 3" = 1' - 0"
12
MULLION OPTIONS - SPREAD
Architectural Design Manual
August 2016
Product specifications may change without notice.
Questions? Consult JELD-WEN customer service.
SITELINE
CLAD-WOOD WINDOW
CASEMENT
11/16"5/8" 1"
1 1/8"7/8" 1 3/8"
5/8" GBG 23/32"
CONTOUR
GBG
1" CONTOUR
GBG
FULL SURROUND
1 3/8" WOOD
GRILLE
FULL SURROUND
1 1/8" WOOD
GRILLE
FULL SURROUND
7/8" WOOD
GRILLE
7/8" 1 1/8" 1 3/8" 2 5/16"
7/8"
BEAD SDL
1 1/8"
BEAD SDL
1 3/8"
BEAD SDL
2 5/16"
BEAD SDL
Scale: 3" = 1' - 0"
13
DIVIDED LITE OPTIONS
Architectural Design Manual
August 2016
Product specifications may change without notice.
Questions? Consult JELD-WEN customer service.
SITELINE
CLAD-WOOD WINDOW
CASEMENT
5/8" 7/8" 1 1/8"
5/8" 1 1/8"7/8"
2 5/16"
2 5/16"
1 3/8"
1 3/8"
5/8"
PUTTY / BEAD
7/8"
PUTTY / BEAD
1 1/8"
PUTTY / BEAD
1 3/8"
PUTTY / BEAD
2 5/16"
PUTTY / BEAD
5/8"
PUTTY / PUTTY
7/8"
PUTTY / PUTTY
1 1/8"
PUTTY / PUTTY
1 3/8"
PUTTY / PUTTY
2 5/16"
PUTTY / PUTTY
5/8" 1 1/8"7/8" 2 5/16"1 3/8"
5/8"
BEAD / PUTTY
7/8"
BEAD / PUTTY
1 1/8"
BEAD / PUTTY
1 3/8"
BEAD / PUTTY
2 5/16"
BEAD / PUTTY
Scale: 3" = 1' - 0"
14
DIVIDED LITE OPTIONS
Architectural Design Manual
August 2016
Product specifications may change without notice.
Questions? Consult JELD-WEN customer service.
SITELINE
CLAD-WOOD WINDOW
CASEMENT
Standard widths for the Siteline Clad Casement:
18"(457mm), 20"(508mm), 24"(610mm), 28"(711mm), 30"(762mm),
32"(813mm), 36"(914mm).
Standard heights for the Siteline Clad Casement:
12"(305mm), 18"(457mm), 20"(508mm), 24"(610mm), 28"(711mm),
30"(762mm), 36"(914mm), 42"(1067mm), 48"(1219mm), 54"(1372mm),
60"(1524mm), 66"(1676mm), 72"(1829mm), 78"(1981mm), 84"(2134mm).
Max Size for Operators: 24" x 84", 30" x 84", (32" x 84") * , (36" x 78")*, (36" x 84")*
* Limited Operation: Sash Limiter (20 Degree Opening)
36" [914]18" [457]
12" [305]
96" [2438]
Scale: NTS
15
MIN-MAX SIZING - STANDARD
Architectural Design Manual
August 2016
Product specifications may change without notice.
Questions? Consult JELD-WEN customer service.
SITELINE
CLAD-WOOD WINDOW
CASEMENT
Standard widths for the Siteline Clad Casement Picture:
42"(1067mm), 48"(1219mm), 54"(1372mm), 60"(1524mm), 66"(1676mm),
72"(1829mm), 84"(2134mm), 96"(2438mm).
Standard heights for the Siteline Clad Casement Picture:
12"(305mm), 18"(457mm), 20"(508mm), 24"(610mm), 28"(711mm),
30"(762mm), 36"(914mm), 42"(1067mm), 48"(1219mm), 54"(1372mm),
60"(1524mm), 66"(1676mm), 72"(1829mm), 78"(1981mm), 84"(2134mm),
96"(2438mm).
Note: 50 sq foot Max Frame Size
96" [2438]
12" [305]
42" [1067] 96" [2438]
Scale: NTS
16
MIN-MAX SIZING - PICTURE
Architectural Design Manual
August 2016
Product specifications may change without notice.
Questions? Consult JELD-WEN customer service.
SITELINE
CLAD-WOOD WINDOW
CASEMENT
FR
AM
E S
IZ
E
DA
YL
IG
HT
O
PE
NIN
G
RO
UG
H O
PE
NIN
G
3/8"
2 1/16"
2 1/16"
1 1/8"
1 1/8"
SA
SH
S
IZ
E
4 9/16"1 1/4"
5 13/16"
4 9/16"1 1/4"
5 13/16"
15/16"
15/16"
SC
RE
EN
S
IZ
E
1 5/8"
2 9/16"
5/8"
3 3/16"
3 3/16"
5/8"
3/8"
Scale: 6" = 1' - 0"
17
OPERATING - VERTICAL SECTION
Architectural Design Manual
August 2016
Product specifications may change without notice.
Questions? Consult JELD-WEN customer service.
SITELINE
CLAD-WOOD WINDOW
CASEMENT
4 9/16"
DA
YLIG
HT
OP
EN
IN
G
1 1/4"
5 13/16"
SA
SH
S
IZ
E
2 1/16"
2 1/16"
FR
AM
E S
IZ
E
RO
UG
H O
PE
NIN
G
3/8"
1 1/8"
3/8"
SC
RE
EN
S
IZ
E
1 5/8"
1 5/8"
1 1/8"
3 3/16"
5/8"
5/8"
4 9/16"1 1/4"
5 13/16"
3 3/16"
15/16"
15/16"
Scale: 6" = 1' - 0"
18
OPERATING - HORIZONTAL SECTION
Architectural Design Manual
August 2016
Product specifications may change without notice.
Questions? Consult JELD-WEN customer service.
SITELINE
CLAD-WOOD WINDOW
CASEMENT
FR
AM
E S
IZ
E
DA
YL
IG
HT
O
PE
NIN
G
RO
UG
H O
PE
NIN
G
3/8"
2 1/16"
2 1/16"
1 1/8"
1 1/8"
SA
SH
S
IZ
E
4 9/16"1 1/4"
5 13/16"
4 9/16"1 1/4"
5 13/16"
15/16"
15/16"
SC
RE
EN
S
IZ
E
1 5/8"
2 9/16"
5/8"
3 3/16"
3 3/16"
5/8"
3/8"
Scale: 6" = 1' - 0"
19
OPERATING IMPACT - VERTICAL SECTION
Architectural Design Manual
August 2016
Product specifications may change without notice.
Questions? Consult JELD-WEN customer service.
SITELINE
CLAD-WOOD WINDOW
CASEMENT
4 9/16"
DA
YL
IG
HT
OP
EN
IN
G
1 1/4"
5 13/16"
SA
SH
S
IZ
E
2 1/16"
2 1/16"
FR
AM
E S
IZ
E
RO
UG
H O
PE
NIN
G
3/8"
1 1/8"
3/8"
SC
RE
EN
S
IZ
E
1 5/8"
1 5/8"
1 1/8"
3 3/16"
5/8"
5/8"
4 9/16"1 1/4"
5 13/16"
3 3/16"
15/16"
15/16"
Scale: 6" = 1' - 0"
20
OPERATING IMPACT - HORIZONTAL SECTION
Architectural Design Manual
August 2016
Product specifications may change without notice.
Questions? Consult JELD-WEN customer service.
SITELINE
CLAD-WOOD WINDOW
CASEMENT
DA
YLIG
HT
O
PE
NIN
G
2 1/16"
2 1/16"
SA
SH
S
IZ
E
4 9/16"1 1/4"
15/16"
3 3/16"
FR
AM
E S
IZ
E
RO
UG
H O
PE
NIN
G
1 1/8"
1 1/8"
4 9/16"1 1/4"
5 13/16"
5/8"
3 3/16"
5/8"
5 13/16"
15/16"
3/8"
3/8"
Scale: 6" = 1' - 0"
21
FIXED - VERTICAL SECTION
Architectural Design Manual
August 2016
Product specifications may change without notice.
Questions? Consult JELD-WEN customer service.
SITELINE
CLAD-WOOD WINDOW
CASEMENT
FR
AM
E S
IZ
E
RO
UG
H O
PE
NIN
G
DA
YL
IG
HT
OP
EN
IN
G
2 1/16"
2 1/16"
SA
SH
S
IZ
E
3/8"
15/16"
1 1/8"
1 1/8"
3/8"
15/16"
4 9/16"1 1/4"
5 13/16"
3 3/16"
4 9/16"1 1/4"
5 13/16"
3 3/16"
5/8"
5/8"
5/8"
Scale: 6" = 1' - 0"
22
Architectural Design Manual
August 2016
Product specifications may change without notice.
Questions? Consult JELD-WEN customer service.
SITELINE
CLAD-WOOD WINDOW
CASEMENT
FIXED - HORIZONTAL SECTION
DA
YL
IG
HT
O
PE
NIN
G
2 1/16"
2 1/16"
SA
SH
S
IZ
E
4 9/16"1 1/4"
15/16"
3 3/16"
FR
AM
E S
IZ
E
RO
UG
H O
PE
NIN
G
1 1/8"
1 1/8"
4 9/16"1 1/4"
5 13/16"
5/8"
3 3/16"
5/8"
5 13/16"
15/16"
3/8"
3/8"
Scale: 6" = 1' - 0"
23
FIXED IMPACT - VERTICAL SECTION
Architectural Design Manual
August 2016
Product specifications may change without notice.
Questions? Consult JELD-WEN customer service.
SITELINE
CLAD-WOOD WINDOW
CASEMENT
FR
AM
E S
IZ
E
RO
UG
H O
PE
NIN
G
DA
YLIG
HT
OP
EN
IN
G
2 1/16"
2 1/16"
SA
SH
S
IZ
E
3/8"
15/16"
1 1/8"
1 1/8"
3/8"
15/16"
4 9/16"1 1/4"
5 13/16"
3 3/16"
4 9/16"1 1/4"
5 13/16"
3 3/16"
5/8"
5/8"
5/8"
Scale: 6" = 1' - 0"
24
FIXED IMPACT - HORIZONTAL SECTION
Architectural Design Manual
August 2016
Product specifications may change without notice.
Questions? Consult JELD-WEN customer service.
SITELINE
CLAD-WOOD WINDOW
CASEMENT
DA
YL
IG
HT
O
PE
NIN
G
2 1/16"
2 1/16"
SA
SH
S
IZ
E
15/16"
15/16"
FR
AM
E S
IZ
E
RO
UG
H O
PE
NIN
G
1 1/8"
1 3/16"
SC
RE
EN
S
IZ
E
1 9/16"
1 5/8"
4 9/16"1 1/4"
3 3/16"
5 13/16"
4 9/16"1 1/4"
3 3/16"
5 13/16"
5/8"
5/8"
3/8"
3/8"
Scale: 6" = 1' - 0"
25
PUSHOUT - VERTICAL SECTION
Architectural Design Manual
August 2016
Product specifications may change without notice.
Questions? Consult JELD-WEN customer service.
SITELINE
CLAD-WOOD WINDOW
CASEMENT
15/16"
DA
YL
IG
HT
OP
EN
IN
G
2 1/16"
2 1/16"
15/16"
SA
SH
S
IZ
E
1 1/8"
4 9/16"1 1/4"
5 13/16"
FR
AM
E S
IZ
E
RO
UG
H O
PE
NIN
G
1 1/8"
3/8"
SC
RE
EN
S
IZ
E
1 9/16"
3 3/16"
5/8"
1 9/16"
3/8"
5/8"
4 9/16"1 1/4"
5 13/16"
3 3/16"
Scale: 6" = 1' - 0"
26
PUSHOUT - HORIZONTAL SECTION
Architectural Design Manual
August 2016
Product specifications may change without notice.
Questions? Consult JELD-WEN customer service.
SITELINE
CLAD-WOOD WINDOW
CASEMENT
DA
YL
IG
HT
O
PE
NIN
G
2 1/16"
2 1/16"
SA
SH
S
IZ
E
15/16"
15/16"
4 9/16"1 1/4"
3 3/16"
5 13/16"
FR
AM
E S
IZ
E
RO
UG
H O
PE
NIN
G
1 1/8"
1 1/8"
5/8"
5/8"
3/8"
3/8"
4 9/16"1 1/4"
3 3/16"
5 13/16"
Scale: 6" = 1' - 0"
27
PUSHOUT FIXED - VERTICAL SECTION
Architectural Design Manual
August 2016
Product specifications may change without notice.
Questions? Consult JELD-WEN customer service.
SITELINE
CLAD-WOOD WINDOW
CASEMENT
15/16"
DA
YL
IG
HT
OP
EN
IN
G
2 1/16"
2 1/16"
15/16"
SA
SH
S
IZ
E
4 9/16"1 1/4"
5 13/16"
3 3/16"
4 9/16"1 1/4"
5 13/16"
3 3/16"
FR
AM
E S
IZ
E
RO
UG
H O
PE
NIN
G
3/8"
1 1/8"
1 1/8"
3/8"
5/8"
5/8"
5/8"
Scale: 6" = 1' - 0"
28
PUSHOUT FIXED - HORIZONTAL SECTION
Architectural Design Manual
August 2016
Product specifications may change without notice.
Questions? Consult JELD-WEN customer service.
SITELINE
CLAD-WOOD WINDOW
CASEMENT
DA
YL
IG
HT
O
PE
NIN
G
SA
SH
S
IZ
E
FR
AM
E S
IZ
E
RO
UG
H O
PE
NIN
G
1 1/8"
5/8"
3/8"
1 1/8"
5/8"
3/8"
4 9/16"1 1/4"
3 3/16"
5 13/16"
2 1/16"
15/16"
2 1/16"
15/16"
4 9/16"1 1/4"
3 3/16"
5 13/16"
Scale: 6" = 1' - 0"
29
RADIUS TOP - VERTICAL SECTION
Architectural Design Manual
August 2016
Product specifications may change without notice.
Questions? Consult JELD-WEN customer service.
SITELINE
CLAD-WOOD WINDOW
CASEMENT
DA
YL
IG
HT
O
PE
NIN
G
FR
AM
E S
IZ
E
RO
UG
H O
PE
NIN
G
4 9/16"1 1/4"
5 13/16"
1 13/16"
1 13/16"
4 9/16"1 1/4"
5 13/16"
1 3/16"
5/8"
1 1/8"
1/2"
3/8"
3/8"
3 3/16"
Scale: 6" = 1' - 0"
30
Architectural Design Manual
August 2016
Product specifications may change without notice.
Questions? Consult JELD-WEN customer service.
SITELINE
CLAD-WOOD WINDOW
CASEMENT
DIRECT SET SEGMENT HEAD - VERTICAL SECTION
3/4"
3/4"
FR
AM
E S
IZ
E
RO
UG
H O
PE
NIN
G
HEAD BOARD
SEAT BOARD
3/8"
3/8"
Scale: NTS
31
BAY & BOW - VERTICAL SECTION
Architectural Design Manual
August 2016
Product specifications may change without notice.
Questions? Consult JELD-WEN customer service.
SITELINE
CLAD-WOOD WINDOW
CASEMENT
4 9/16"
3/8" FRAME SIZE
ROUGH OPENING
Scale: NTS
32
30° BAY - HORIZONTAL SECTION
Architectural Design Manual
August 2016
Product specifications may change without notice.
Questions? Consult JELD-WEN customer service.
SITELINE
CLAD-WOOD WINDOW
CASEMENT
4 9/16"
3/8" FRAME SIZE
ROUGH OPENING
Scale: NTS
33
45° BAY - HORIZONTAL SECTION
Architectural Design Manual
August 2016
Product specifications may change without notice.
Questions? Consult JELD-WEN customer service.
SITELINE
CLAD-WOOD WINDOW
CASEMENT
4 9/16"
3/8" FRAME SIZE
ROUGH OPENING
Scale: NTS
34
BOW 3 WIDE - HORIZONTAL SECTION
Architectural Design Manual
August 2016
Product specifications may change without notice.
Questions? Consult JELD-WEN customer service.
SITELINE
CLAD-WOOD WINDOW
CASEMENT
4 9/16"
3/8" FRAME SIZE
ROUGH OPENING
Scale: NTS
35
BOW 4 WIDE - HORIZONTAL SECTION
Architectural Design Manual
August 2016
Product specifications may change without notice.
Questions? Consult JELD-WEN customer service.
SITELINE
CLAD-WOOD WINDOW
CASEMENT
4 9/16"
3/8" FRAME SIZE
ROUGH OPENING
Scale: 3" = 1' - 0"
36
Architectural Design Manual
August 2016
Product specifications may change without notice.
Questions? Consult JELD-WEN customer service.
SITELINE
CLAD-WOOD WINDOW
CASEMENT
BOW 5 WIDE - HORIZONTAL SECTION
4 9/16"
3/8" FRAME SIZE
ROUGH OPENING
Scale: NTS
37
Architectural Design Manual
August 2016
Product specifications may change without notice.
Questions? Consult JELD-WEN customer service.
SITELINE
CLAD-WOOD WINDOW
CASEMENT
BOW 6 WIDE - HORIZONTAL SECTION