siteline ex primed casement...

79
Architectural Detail Manual August 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-1 TABLE OF CONTENTS Specifications ........................................................... 2-2 Quick Spec Guide ....................................................... 2-4 Elevations/Sizes: 1/4” Scale ............................................... 2-6 Casement ...................................................... 2-9 Casement Picture ................................................ 2-25 Casement Picture with Flankers .................................... 2-32 Casement Sector Top ............................................. 2-37 Sash Glazing Options: 3” Scale ............................................ 2-47 Trim Options: 3” Scale .................................................... 2-49 Jamb Options: 3” Scale ................................................... 2-51 Standard Mullion Options ................................................. 2-52 Lite Cut Information ...................................................... 2-53 Unit Sizing, Rough Openings & Masonry Openings ........................... 2-56 Section Details: 6” Scale ................................................. 2-57 Bay & Bow Specification and Rough Opening Information ..................... 2-66 Section Details: 3” Scale (Bow & Bay) ...................................... 2-71 Premium Wood Siteline EX Primed Casement Windows

Upload: others

Post on 18-Mar-2020

11 views

Category:

Documents


0 download

TRANSCRIPT

Architectural Detail ManualAugust 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-1

TABLE OF CONTENTS

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2

Quick Spec Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4

Elevations/Sizes: 1/4” Scale . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6

Casement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9

Casement Picture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-25

Casement Picture with Flankers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-32

Casement Sector Top . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-37

Sash Glazing Options: 3” Scale . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-47

Trim Options: 3” Scale . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-49

Jamb Options: 3” Scale . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-51

Standard Mullion Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-52

Lite Cut Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-53

Unit Sizing, Rough Openings & Masonry Openings . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-56

Section Details: 6” Scale . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-57

Bay & Bow Specification and Rough Opening Information . . . . . . . . . . . . . . . . . . . . . 2-66

Section Details: 3” Scale (Bow & Bay) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-71

Premium Wood

Siteline EX Primed Casement Windows

Architectural Detail ManualAugust 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-2

PRODUCT SPECIFICATIONS

EXTERIOR FINISH

All exterior surfaces completely covered with factory-applied latexprimer.

AURALASTR WOODAuraLastR wood is fundamentally different from wood resultingfrom traditional millwork preservation processes in that it uses aproprietary vacuum/pressure process to provide protectionthroughout the wood parts used to make windows and doors.AuraLastR wood is distinguished from wood using the currentpreservation methods by its unique ability to achieve greaterpenetration of the active ingredients into the wood parts, with apenetration of the treatment being a minimum of 92%.

INTERIOR FINISH

All interior surfaces are unfinished clear pine ready for on sitefinishing. Primed and pre-finished interiors are available in paint:Pure White, Extra White, Natural Choice, Moderate White; in stain:Wheat, Cherry, Fruitwood, Cordovan, Cider and Clear Lacquer.

FRAME

Frame is assembled from select kiln dried pine using AuraLastRwoodon all exterior parts. Frame thickness is 1-5/32” (29.4mm) at head andside jamb and at sill. Basic jamb width is 3-3/4” (95.3mm). Standardjamb width is 4-9/16” (116mm). Frame features machine clampedassembly, which insures accurate squaring of unit, and frame cornersare tightly secured with metal fasteners and adhesive. Finished frameincludes all exterior casing.

SASH

Sash is 1-7/16” (36.5mm) thick with select kiln-dried pine usingAuraLastR wood. Stiles and rails are mortise and tenoned, machineclamped for squareness and secured with metal fasteners.

GLAZING

3/4” (19mm) thick sealed insulating glass is constructed from twopanes of glass, utilizing a continuous roll formed stainless steel spacerwith dual seal sealant. The glass is mounted into the sash using asilicone-glazing compound and secured with interior applied profiledwood stops. All insulating glass units comply with the performancerequirements of IGCC in accordance with either ASTM E774 or E2190.

GLAZING OPTIONS

3/4” insulating glass available in Low-E with Argon, Low-E, Low-E 366,Clear, Neat Glass, reflective, tinted, or obscure, tempered or otherspecialty glass as specified. Preserve® film is a 0.003” thickpolyethylene film with a low tack acrylic adhesive applied to the glassfor protection during shipping and installation. 4,000 foot elevationsand higher require a capillary tube to equalize environmental stress(otherwise known as High Altitude glazing). High Altitude glazingdoes not allow the use of Argon as listed under glazing options.

WEATHER-STRIPPING

Engineered system combines a flexible, bulb weather-strip applied toall sides of sash with thermoplastic rubber bulb applied to the fullperimeter of the frame.

HARDWARE

Sash pivot on concealed hinges with sliding steel reinforced nylonshoes in an integral frame track. Stainless steel concealed lockingsystem is standard, and the window locks sequentially. EntryGarddual arm retro operator has removable polycarbonate cover, die castzinc bash and hardened steel worm gears and arms. Hinges and retrooperator arms feature stainless steel. The die cast locking lever islocated on the side jamb at the lower corner of the window oppositethe operator and has a molded bezel cover that snaps over the routon the side stop. Units under 20” wide will feature a dyad operator.Color choices for locks and operator covers are White, ChestnutBronze, Desert Sand or optional Bright Brass, Antique Brass, PolishedBrass, Brushed Chrome or Imitation Oil Rubbed Bronze.

INTERIOR INSECT SCREENS

Charcoal fiberglass screen cloth (18x16 mesh) set in painted rollformed aluminum frame fitted to the inside of the window with allnecessary hardware, in White, Chestnut Bronze, Desert Sand oroptional Bright Brass, Antique Brass, Polished Brass, Brushed Chromeor Imitation Oil Rubbed Bronze. Aluminum mesh and Phantomscreens are also available. Insect screens are intended to allow air andlight in and to keep insects out. They are not intended to keep anyoneor anything from falling through an open window. For safety screensor other security devices contact your local building supply retailer.

GRILLES

SDL (Simulated Divided Lites) - wood muntins permanently appliedto the exterior of the insulating glass unit (not available on texturedglass) in 7/8” (22mm), 1-1/8”(28.5mm), or 1-3/8” (34.9mm) widths, anda putty profile in 5/8” (15.9mm), 7/8” (22mm) and 1-1/8” (28.5mm)widths only. SDL is standard with a light bronze internal shadow barto give a true divided lite appearance. As an option, SDL may beordered with a silver shadow bar. Clear wood interior muntin barsmatch the exterior muntin width and are permanently bonded to theinterior of the glass. Also available is a 2-5/16” (59mm) SDL bar, whichsimulates a double-hung checkrail.

Full Surround Wood Grilles - Rectangular unfinished clear pinewood grilles in 7/8” (22mm), 1-1/8” (28.6mm) and 1-3/8” (35mm) areavailable in patterns selected by the owner.

GBG (Grilles between the Glass) - 5/8” (15.9mm) flat and 23/32” or 1”contour mounted between the glass panes suspended within the aircavity.

EXTERIOR TRIM

1-3/32” (27.8mm) x 2” (50.8mm) brickmould with 1-1/16” (27mm) x1-3/4” (44.5mm) nosing is standard. Flat casing is available as 1-3/32”(27.8mm) x 2” (50.8mm), 1-3/32” (27.8mm) x 3-1/2” (89mm), 1-3/32”(27.8mm) x 4-1/2” (114.3mm), and 1-3/32” (27.8mm) x 5-1/2”(139.7mm). The following profiled casings are available: RB-3 andAdams as 1-1/16” x 3-1/2” (89mm), and Williamsburg 1-3/16” x 3-1/4”.

Continued on next page

Premium Wood

Siteline EX Primed Casement Windows

Architectural Detail ManualAugust 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-3

PRODUCT SPECIFICATIONS

EXTENSION JAMBS

Extension jambs are factory applied to the interior on all four sides ofthe frame and are 4/4 standard thick pine to accommodate walldepths up to 8-1/2” with one piece, and up to 12” with two pieces.9/16” (14.2mm) and 5/4 option or 5/4-4/4 stacked option also availab

INSTALLATION

Installation per JELD-WEN Installation Method for Wood WindowsJII003 or JII012. See www.jeld-wen.com/resources for instructions.

PERFORMANCE

NFRC Certified - (Rated and labeled in accordance with NFRC)

WDMA Hallmark Certified -In accordance with AAMA/NWWDA/101/I.S.2-97

Premium Wood

Siteline EX Primed Casement Windows

Architectural Detail ManualAugust 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-4

QUICK SPEC GUIDE

SPECIFICATION STANDARD FEATURESOPTIONAL FEATURES

Some options may require additional lead times.Consult your JELD-WEN Sales Representative.

FRAME S Fingerjoint Wood

EXTERIOR FINISH S Primed S Natural

EXTERIOR TRIM S 1-3/32” BrickmouldS Drip CapS Wood Sill Nose

S Flat Casing: 1-3/32” x 2”, 3-1/2”, 4-1/2”, and 5-1/2”S Williamsburg Casing: 1-3/16” x 3-1/4”S Adams Casing: 1-1/16” x 3-1/2”S RB3 Casing: 1-1/16” x 3-1/12”S 1-7/32” x 4-1/2” BackbandS No Brickmould OptionS Historical Sill Nose

INTERIOR FINISH S Priming Available

Pre-finished Interior Options are:S Paint - Pure White, Extra White, Natural Choice,

Moderate WhiteS Stain - Wheat, Fruitwood, Cherry, Cordovan, CiderS Clear Lacquer

SIZE S Width:Operators & Stationary Casements

18, 20, 24, 28, 30, 32, 36Casement Fixed Units

42, 48, 54, 60, 66, 72, 84, 96S Height:

Operators & Stationary Casements12, 18, 20, 24, 28, 30, 36, 42, 48, 54, 60, 66,72, 78, 84, 96

S For RO, add 3/4”

S Operator:Any width: 14-1/4” to 36”

S Stationary:Any Width: 12“ to 96”

S Operator & Stationary:Operable Heights: 18” to 84”Stationary Heights: 12” to 96”

S Available as Stationary Only:All 12” heights28” and 30” x 84”32” and 36” x 78”, 84”

S For RO, add 3/4”

GLAZING S Low-E Insulating GlassS Preserve® Protective Film

S Clear

S ObscureS BronzeS Low-E 366

S Neat GlassS Dual Low-E

S Reflective

S TemperedS Decorative Glass

d Craftsmand Classicd Contemporaryd Estate

S Custom DesignCapability

S High Altitude

GLAZING S Low-E Insulating GlassS Preserve® Protective Film

S High Altitude

GRILLES S 5/8” Flat, 23/32” or 1” Contour GBGS 7/8”, 1-1/8”, 1-3/8” Full Surround Wood Grilles

SDL Bead Profile:S 7/8”, 1-1/8”, 1-3/8”, 2-5/16” with Light Bronze

Shadow BarS 7/8”, 1-1/8”, 1-3/8”, 2-5/16” with Silver Shadow Bar

SDL Putty Profile:S 5/8”, 7/8”, 1-1/8” with Light Bronze Shadow BarS 5/8”, 7/8”, 1-1/8” with Silver Shadow Bar

Continued on next page

Premium Wood

Siteline EX Primed Casement Windows

Architectural Detail ManualAugust 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-5

QUICK SPEC GUIDE

SPECIFICATION STANDARD FEATURESOPTIONAL FEATURES

Some options may require additional lead times.Consult your JELD-WEN Sales Representative.

HARDWARE S Standard Folding Nesting HandleS Concealed Locking System

S T-Handle S Round Knob

HARDWARE COLOR S WhiteS Desert SandS Chestnut Bronze

S Antique BrassS Polished Brass

S Brushed ChromeS Oil Rubbed Bronze

JAMB S 4-9/16” S Minimum: 3-3/4”S Maximum: 8-1/2” (one piece)S Maximum: 12” (two piece)

SCREENS S BetterVuet S Aluminum Mesh availableS Phantom Screen - Limitations apply, factory-

appliedS UltraVuet

SCREEN FRAME COLOR S Brilliant WhiteS Desert SandS Chestnut Bronze

Premium Wood

Siteline EX Primed Casement Windows

Architectural Detail ManualAugust 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-6

Wood casement windows may be specified as ”dimensional”, byadjusting the desired rough opening width or height in 1/4” incrementsfrom standard.

Wood casement windows are available with left or right hand operation,or stationary (non-venting). Operating mechanism includes corrosionresistant steel hinges and dual arm roto-type operator with hardenedsteel gears and operating arms. Sash locks are concealed unison typewith an exposed locking lever and escutcheon plate. There are severalinterior hardware finish options. Refer to the Specifications for finishoptions.

Wood casement windows may be mulled above, below, or beside other woodcasement windows, or other wood window products. Factory assembled mulls arelimited in height (100”), width (150”), and a total area (75 square feet).

DIMENSIONAL WINDOWS

MULTIPLE ASSEMBLIES

GENERAL INFORMATIONCASEMENT

Premium Wood

Siteline EX Primed Casement Windows

Architectural Detail ManualAugust 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-7

LEFTHAND

RIGHTHAND

CASEMENT UNIT HANDING:UNIT HANDING IS DEFINED (FROMTHE EXTERIOR) AS THEDIRECTION THE SASH OPENS.

OPERATOR OPERATOR

HANDING & OPERATIONCASEMENT

Premium Wood

Siteline EX Primed Casement Windows

Architectural Detail ManualAugust 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-8

GENERAL CASEMENT NOTES

ELEVATION DRAWINGS UTILIZE A LIMITED NUMBER OF PROJECTED LINES TO PRODUCE A RUDIMENTARY DRAWINGINTENDED TO BE USED IN A SMALL GRAPHICAL SCALE. ELEVATIONS ARE VIEWED PERPENDICULAR FROM THEEXTERIOR OF THE STRUCTURE. IF MORE DIMENSIONS ARE NEEDED, USE THE SECTION DRAWINGS FOR MORECOMPLETE DEPICTIONS.

BOOK CODE

EWC1818

M.O. Adams/Flat CasingRough Opening

M.O. Brickmould

Frame SizeGlass Size

Masonry Openings for Brickmould, Flat & Adams Casing.Vertical measurements include subsill.(Subtract 1/2” from Masonry Opening for Unit Size)

THE FIRST TWO NUMBERSINDICATE THE UNIT WIDTH

THE LAST TWO NUMBERS INDICATETHE UNIT HEIGHT

’EWC’ INDICATESSITELINE EX WOOD CASEMENT

ELEVATION SYMBOL LEGEND:

M.O. MASONRY OPENING

##* NUMBER INDICATES DESIGN PRESSURE (DP) RATING WITHSTANDARD GLAZING.

##** NUMBER INDICATES OPTIONAL DESIGN PRESSURE (DP)RATING.

E BASIC UNIT CLEAR OPENING EXCEEDS 20” IN WIDTH, 24”IN HEIGHT & A MINIMUM OF 5.7 SQ. FT.

S AVAILABLE AS STATIONARY ONLY.

1. SITELINE EX WOOD CASEMENT (EWC) UNITS ARE AVAILABLE ASOPERATING OR STATIONARY UNITS.

2. ’EWCP’ IN A BOOK CODE DENOTES THE UNIT IS A WOODCASEMENT PICTURE (STATIONARY) UNIT.

3. UNIT ELEVATIONS ARE SHOWN WITH BRICKMOULD AND SUBSILL.

4. ELEVATION DRAWINGS SHOW STANDARD LITE CUTS FOR 7/8”[22]OR 1 1/8”[29] GRILLE BARS OR SIMULATED DIVIDED LITE.

5. OPERATING UNITS ARE AVAILABLE AS LEFT OR RIGHT HANDOPERATION.

6. DIMENSIONAL VALUES IN PARENTHESES ARE MILLIMETERCONVERSIONS.

7. ALL GLASS SIZES ARE NOMINAL.

STANDARD LITE BREAKUPS ARESHOWN ON EACH ELEVATION DRAWING

18 3/4”(476)

21 1/2”(546)

12 3/32”(307)

24 1/2”(645)

18”(457)

20 15/16”(532)

18 3/4”(476)

12 3/32”(307)18”(457)

22 7/16”(570) 35*50**

DP RatingOptional DP Rating

ELEVATION NOTESCASEMENT

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-9

SCALE 1/4” = 1’

Architectural Detail ManualAugust 2010

1-WIDE UNITS

Note: Elevations shown DO NOT have exterior trim. Subtract 1/2” (12.7) from M.O. (Masonry Opening) for Unit Sizes. Masonry Openings above include SillNose, see Trim Options page for Sill Nose specifications. For other Trim Options refer to the Unit Sizing, Rough Opening & Masonry Openings page.

18”(

457)

183/

4”(4

76)

227/

16”(

570)

2015

/16”

(532

)

12 3/32”(307)18”(457)

18 3/4”(476)24 1/2”(622)21 1/2”(546)

20”(

508)

203/

4”(5

27)

247/

16”(

621)

2215

/16”

(583

)

24”(

610)

243/

4”(6

29)

287/

16”(

722)

2615

/16”

(684

)

30”(

762)

303/

4”(7

81)

347/

16”(

875)

3215

/16”

(837

)

36”(

914)

363/

4”(9

33)

407/

16”(

1027

)38

15/1

6”(9

89)

42”(

1067

)42

3/4”

(108

6)46

7/16

”(11

80)

4415

/16”

(114

1)

48”(

1219

)48

3/4”

(123

8)52

7/16

”(13

32)

5015

/16”

(129

4)

20”(508)20 3/4”(527)26 1/2”(673)23 1/2”(597)

24”(610)24 3/4”(629)30 1/2”(775)27 1/2”(699)

28”(711)28 3/4”(730)34 1/2”(876)31 1/2”(800)

30”(762)30 3/4”(781)36 1/2”(927)33 1/2”(851)

36”(914)36 3/4”(933)

42 1/2”(1080)39 1/2”(1033)

EWC1812 EWC2012 EWC2412 EWC2812 EWC3012 EWC3612

63/

32”(

155)

12”(

305)

123/

4”(3

24)

167/

16”(

418)

1415

/16”

(379

) 14 3/32”(358) 18 3/32”(460) 22 3/32”(561) 24 3/32”(612) 30 3/32”(764)

28”(

711)

283/

4”(7

30)

123/

32”(

307)

143/

32”(

358)

183/

32”(

460)

223/

32”(

561)

243/

32”(

612)

303/

32”(

764)

363/

32”(

917)

423/

32”(

1069

)

327/

16”(

824)

3015

/16”

(786

)

EWC1818 EWC2018 EWC2418 EWC2818 EWC3018 EWC3618

EWC1820 EWC2020 EWC2420 EWC2820 EWC3020 EWC3620

EWC1824 EWC2024 EWC2424 EWC2824 EWC3024 EWC3624

EWC1828 EWC2028 EWC2428 EWC2828 EWC3028 EWC3628

EWC1830 EWC2030 EWC2430 EWC2830 EWC3030 EWC3630

EWC1836 EWC2036 EWC2436 EWC2836 EWC3036 EWC3636

EWC1842 EWC2042 EWC2442 EWC2842 EWC3042 EWC3642

EWC1848 EWC2048 EWC2448 EWC2848 EWC3048 EWC3648

E E E

E

E

E

EWC3212

EWC3218

EWC3220

EWC3224

EWC3228

EWC3230

EWC3236

EWC3242

EWC3248

32”(813)32 3/4”(832)38 1/2”(978)35 1/2”(902)

26 3/32”(663)DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGM.O. ADAMS/FLAT CASING

M.O. BRICKMOULD

ELEVATION SYMBOL LEGEND:

VALUES IN () ARE IN MILLIMETER CONVERSIONSM.O. = MASONRY OPENING

S AVAILABLE AS STATIONARY ONLY.

##** INDICATES OPTIONAL DESIGN PRESSURE (DP) RATING##* INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING

E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.

S S S S S S S 50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-10

SCALE 1/4” = 1’

Architectural Detail ManualAugust 2010

1-WIDE UNITS

Note: Elevations shown DO NOT have exterior trim. Subtract 1/2” (12.7) from M.O. (MasonryOpening) for Unit Sizes. Masonry Openings above include Sill Nose, see Trim Optionspage for Sill Nose specifications. For other Trim Options refer to the Unit Sizing, RoughOpening & Masonry Openings page.

54”(

1372

)54

3/4”

(139

1)58

7/16

”(14

84)

5615

/16”

(144

6)

60”(

1524

)60

3/4”

(154

3)64

7/16

”(16

37)

6215

/16”

(159

9)

66”(

1676

)66

3/4”

(169

5)70

7/16

”(17

89)

6815

/16”

(175

1)

72”(

1829

)72

3/4”

(184

8)76

7/16

”(19

42)

7415

/16”

(190

3)

78”(

1981

)78

3/4”

(200

0)82

7/16

”(20

94)

8015

/16”

(205

6)

483/

32”(

1222

)54

3/32

”(13

74)

603/

32”(

1526

)66

3/32

”(16

79)

723/

32”(

1831

)

12 3/32”(307)18”(457)

18 3/4”(476)24 1/2”(622)21 1/2”(546)

20”(508)20 3/4”(527)26 1/2”(673)23 1/2”(597)

24”(610)24 3/4”(629)30 1/2”(775)27 1/2”(699)

28”(711)28 3/4”(730)34 1/2”(876)31 1/2”(800)

30”(762)30 3/4”(781)36 1/2”(927)33 1/2”(851)

36”(914)36 3/4”(933)

42 1/2”(1080)39 1/2”(1033)

14 3/32”(358) 18 3/32”(460) 22 3/32”(561) 24 3/32”(612) 30 3/32”(764)

EWC1854 EWC2054 EWC2454 EWC2854 EWC3054 EWC3654

EWC1860 EWC2060 EWC2460 EWC2860 EWC3060 EWC3660

EWC1866 EWC2066 EWC2466 EWC2866 EWC3066 EWC3666

EWC1872 EWC2072 EWC2472 EWC2872 EWC3072 EWC3672

EWC1878 EWC2078 EWC2478 EWC2878 EWC3078 EWC3678

E

E

E

E

E

E

E

E

E

E

E

E

E E

E

E

E

E

E

EWC3254

EWC3260

EWC3266

EWC3272

EWC3278

32”(813)32 3/4”(832)38 1/2”(978)35 1/2”(902)

26 3/32”(663)DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGM.O. ADAMS/FLAT CASING

M.O. BRICKMOULD

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

S

ELEVATION SYMBOL LEGEND:

VALUES IN () ARE IN MILLIMETER CONVERSIONSM.O. = MASONRY OPENING

S AVAILABLE AS STATIONARY ONLY.

##** INDICATES OPTIONAL DESIGN PRESSURE (DP) RATING##* INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING

E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL CODES MAY DIFFER. ALWAYS REFERTO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS. CHECK WITH LOCAL OFFICIALS TO ENSURECOMPLIANCE BEFORE INSTALLING THE UNIT.

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-11

SCALE 1/4” = 1’

Architectural Detail ManualAugust 2010

1-WIDE UNITS

Note: Elevations shown DO NOT have exterior trim. Subtract 1/2” (12.7) from M.O. (Masonry Opening) for Unit Sizes. Masonry Openings above include SillNose, see Trim Options page for Sill Nose specifications. For other Trim Options refer to the Unit Sizing, Rough Opening & Masonry Openings page.

ELEVATION SYMBOL LEGEND:

VALUES IN () ARE IN MILLIMETER CONVERSIONSM.O. = MASONRY OPENING

S AVAILABLE AS STATIONARY ONLY.

##** INDICATES OPTIONAL DESIGN PRESSURE (DP) RATING##* INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING

84”(

2134

)84

3/4”

(215

3)88

7/16

”(22

46)

8615

/16”

(220

8)

783/

32”(

1984

)

12 3/32”(307)18”(457)

18 3/4”(476)24 1/2”(622)21 1/2”(546)

20”(508)20 3/4”(527)26 1/2”(673)23 1/2”(597)

24”(610)24 3/4”(629)30 1/2”(775)27 1/2”(699)

28”(711)28 3/4”(730)34 1/2”(876)31 1/2”(800)

30”(762)30 3/4”(781)36 1/2”(927)33 1/2”(851)

36”(914)36 3/4”(933)

42 1/2”(1080)39 1/2”(1033)

14 3/32”(358) 18 3/32”(460) 22 3/32”(561) 24 3/32”(612) 30 3/32”(764)

EWC1884 EWC2084 EWC2484 EWC2884 EWC3084 EWC3684

EWC1896 EWC2096 EWC2496 EWC2896 EWC3096 EWC3696

96”(

2438

)96

3/4”

(245

7)10

07/

16”(

2551

)98

15/1

6”(2

513)

903/

32”(

2288

)

EWC3284

EWC3296

32”(813)32 3/4”(832)38 1/2”(978)35 1/2”(902)

26 3/32”(663)DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGM.O. ADAMS/FLAT CASING

M.O. BRICKMOULD

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

S S S S

S S S SSSS

35* 35* 35* 35* 35* 35* 35*

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-12Architectural Detail ManualAugust 2010

SCALE 1/8” = 1’

2-WIDE UNITS

12 3/32”(307)[2]36”(914)

36 3/4”(933)42 1/2”(1080)39 1/2”(1003)

18”(

457)

183/

4”(4

76)

227/

16”(

570)

2015

/16”

(532

)

20”(

508)

203/

4”(5

27)

247/

16”(

621)

2215

/16”

(583

)

24”(

610)

243/

4”(6

29)

287/

16”(

722)

2615

/16”

(684

)

30”(

762)

303/

4”(7

81)

347/

16”(

875)

3215

/16”

(837

)

36”(

914)

363/

4”(9

33)

407/

16”(

1027

)38

15/1

6”(9

89)

42”(

1067

)42

3/4”

(108

6)46

7/16

”(11

80)

4415

/16”

(114

1)

48”(

1219

)48

3/4”

(123

8)52

7/16

”(13

32)

5015

/16”

(129

4)

54”(

1372

)54

3/4”

(139

1)58

7/16

”(14

84)

5615

/16”

(144

6)

60”(

1524

)60

3/4”

(154

3)64

7/16

”(16

37)

6215

/16”

(159

9)

66”(

1676

)66

3/4”

(169

5)70

7/16

”(17

89)

6815

/16”

(175

1)

40”(1016)40 3/4”(1035)46 1/2”(1181)43 1/2”(1105)

48”(1219)48 3/4”(1238)54 1/2”(1384)51 1/2”(1308)

56”(1422)56 3/4”(1441)62 1/2”(1588)59 1/2”(1511)

60”(1524)60 3/4”(1543)66 1/2”(1689)63 1/2”(1613)

72”(1829)72 3/4”(1848)78 1/2”(1994)75 1/2”(1918)

EWC1812-2 EWC2012-2 EWC2412-2 EWC2812-2 EWC3012-2 EWC3612-263/

32”(

155)

12”(

305)

123/

4”(3

24)

167/

16”(

418)

1415

/16”

(379

)

28”(

711)

283/

4”(7

30)

327/

16”(

824)

3015

/16”

(786

)

123/

32”(

307)

143/

32”(

358)

183/

32”(

460)

223/

32”(

561)

243/

32”(

612)

303/

32”(

764)

363/

32”(

917)

423/

32”(

1069

)48

3/32

”(12

22)

543/

32”(

1374

)60

3/32

”(15

26)

14 3/32”(358)[2] 18 3/32”(460)[2] 22 3/32”(561)[2] 24 3/32”(612)[2] 30 3/32”(764)[2]

EWC1818-2 EWC2018-2 EWC2418-2 EWC2818-2 EWC3018-2 EWC3618-2

EWC1820-2 EWC2020-2 EWC2420-2 EWC2820-2 EWC3020-2 EWC3620-2

EWC1824-2 EWC2024-2 EWC2424-2 EWC2824-2 EWC3024-2 EWC3624-2

EWC1828-2 EWC2028-2 EWC2428-2 EWC2828-2 EWC3028-2 EWC3628-2

EWC1830-2 EWC2030-2 EWC2430-2 EWC2830-2 EWC3030-2 EWC3630-2

EWC1836-2 EWC2036-2 EWC2436-2 EWC2836-2 EWC3036-2 EWC3636-2

EWC1842-2 EWC2042-2 EWC2442-2 EWC2842-2 EWC3042-2 EWC3642-2

EWC1848-2 EWC2048-2 EWC2448-2 EWC2848-2 EWC3048-2 EWC3648-2

EWC1854-2 EWC2054-2 EWC2454-2 EWC2854-2 EWC3054-2 EWC3654-2

EWC1860-2 EWC2060-2 EWC2460-2 EWC2860-2 EWC3060-2 EWC3660-2

EWC1866-2 EWC2066-2 EWC2466-2 EWC2866-2 EWC3066-2 EWC3666-2

E

E

E

E

E

E

E

E

E

E

E

EWC3212-2

EWC3218-2

EWC3220-2

EWC3224-2

EWC3228-2

EWC3230-2

EWC3236-2

EWC3242-2

EWC3248-2

EWC3254-2

EWC3260-2

EWC3266-2

E

E

E

E

64”(1626)64 3/4”(1645)70 1/2”(1791)67 1/2”(1715)

26 3/32”(663)[2]

E

E

E

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGM.O. ADAMS/FLAT CASING

M.O. BRICKMOULD

Note: Elevations shown DO NOT have exterior trim. Subtract 1/2” (12.7) from M.O. (Masonry Opening) for Unit Sizes. Masonry Openings above include SillNose, see Trim Options page for Sill Nose specifications. For other Trim Options refer to the Unit Sizing, Rough Opening & Masonry Openings page.

S S S S S S S

ELEVATION SYMBOL LEGEND:

VALUES IN () ARE IN MILLIMETER CONVERSIONSM.O. = MASONRY OPENING

S AVAILABLE AS STATIONARY ONLY.

E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL CODES MAY DIFFER. ALWAYS REFERTO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS. CHECK WITH LOCAL OFFICIALS TO ENSURECOMPLIANCE BEFORE INSTALLING THE UNIT.

VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-13Architectural Detail ManualAugust 2010

SCALE 1/8” = 1’

2-WIDE UNITS

Note: Elevations shown DO NOT have exterior trim. Subtract 1/2” (12.7) from M.O. (Masonry Opening) for Unit Sizes. Masonry Openings above include SillNose, see Trim Options page for Sill Nose specifications. For other Trim Options refer to the Unit Sizing, Rough Opening & Masonry Openings page.

72”(

1829

)72

3/4”

(184

8)76

7/16

”(19

42)

7415

/16”

(190

3)

78”(

1981

)78

3/4”

(200

0)82

7/16

”(20

94)

8015

/16”

(205

6)

663/

32”(

1679

)72

3/32

”(18

31)

12 3/32”(307)[2]36”(914)

36 3/4”(933)42 1/2”(1080)39 1/2”(1003)

40”(1016)40 3/4”(1035)46 1/2”(1181)43 1/2”(1105)

48”(1219)48 3/4”(1238)54 1/2”(1384)51 1/2”(1308)

56”(1422)56 3/4”(1441)62 1/2”(1588)59 1/2”(1511)

60”(1524)60 3/4”(1543)66 1/2”(1689)63 1/2”(1613)

72”(1829)72 3/4”(1848)78 1/2”(1994)75 1/2”(1918)

14 3/32”(358)[2] 18 3/32”(460)[2] 22 3/32”(561)[2] 24 3/32”(612)[2] 30 3/32”(764)[2]

EWC1872-2 EWC2072-2 EWC2472-2 EWC2872-2 EWC3072-2 EWC3672-2

EWC1878-2 EWC2078-2 EWC2478-2 EWC2878-2 EWC3078-2 EWC3678-2

E E

EWC3272-2

EWC3278-2

E

E

64”(1626)64 3/4”(1645)70 1/2”(1791)67 1/2”(1715)

26 3/32”(663)[2]

E

E

E E

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGM.O. ADAMS/FLAT CASING

M.O. BRICKMOULD

ELEVATION SYMBOL LEGEND:

VALUES IN () ARE IN MILLIMETER CONVERSIONSM.O. = MASONRY OPENING

E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.

VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-14Architectural Detail ManualAugust 2010

SCALE 1/8” = 1’

3-WIDE UNITS

Note: Elevations shown DO NOT have exterior trim. Subtract 1/2” (12.7) from M.O. (Masonry Opening) for Unit Sizes. Masonry Openings above include Sill Nose, seeTrim Options page for Sill Nose specifications. For other Trim Options refer to the Unit Sizing, Rough Opening & Masonry Openings page.

12 3/32”(307)[3]54”(1372)

54 3/4”(1391)60 1/2”(1537)57 1/2”(1461)

14 3/32”(358)[3] 18 3/32”(460)[3] 22 3/32”(561)[3]84”(2134)

84 3/4”(2153)90 1/2”(2299)87 1/2”(2223)

24 3/32”(612)[3]90”(2286)

90 3/4”(2305)96 1/2”(2451)93 1/2”(2375)

60”(1524)60 3/4”(1543)66 1/2”(1689)63 1/2”(1613)

72”(1829)72 3/4”(1848)78 1/2”(1994)75 1/2”(1918)

EWC1812-3 EWC2012-3 EWC2412-3 EWC2812-3 EWC3012-3

EWC1818-3 EWC2018-3 EWC2418-3 EWC2818-3 EWC3018-3

EWC1820-3 EWC2020-3 EWC2420-3 EWC2820-3 EWC3020-3

EWC1824-3 EWC2024-3 EWC2424-3 EWC2824-3 EWC3024-3

EWC1830-3 EWC2030-3 EWC2430-3 EWC2830-3 EWC3030-3

EWC1836-3 EWC2036-3 EWC2436-3 EWC2836-3 EWC3036-3

EWC1842-3 EWC2042-3 EWC2442-3 EWC2842-3 EWC3042-3

EWC1848-3 EWC2048-3 EWC2448-3 EWC2848-3 EWC3048-3

EWC1854-3 EWC2054-3 EWC2454-3 EWC2854-3 EWC3054-3

EWC1860-3 EWC2060-3 EWC2460-3 EWC2860-3 EWC3060-3

EWC1866-3 EWC2066-3 EWC2466-3 EWC2866-3 EWC3066-3

EWC1828-3 EWC2028-3 EWC2428-3 EWC2828-3 EWC3028-3

18”(

457)

183/

4”(4

76)

227/

16”(

570)

2015

/16”

(532

)

20”(

508)

203/

4”(5

27)

247/

16”(

621)

2215

/16”

(583

)

24”(

610)

243/

4”(6

29)

287/

16”(

722)

2615

/16”

(684

)

30”(

762)

303/

4”(7

81)

347/

16”(

875)

3215

/16”

(837

)

36”(

914)

363/

4”(9

33)

407/

16”(

1027

)38

15/1

6”(9

89)

42”(

1067

)42

3/4”

(108

6)46

7/16

”(11

80)

4415

/16”

(114

1)

48”(

1219

)48

3/4”

(123

8)52

7/16

”(13

32)

5015

/16”

(129

4)

54”(

1372

)54

3/4”

(139

1)58

7/16

”(14

84)

5615

/16”

(144

6)

60”(

1524

)60

3/4”

(154

3)64

7/16

”(16

37)

6215

/16”

(159

9)

66”(

1676

)66

3/4”

(169

5)70

7/16

”(17

89)

6815

/16”

(175

1)

63/

32”(

155)

12”(

305)

123/

4”(3

24)

167/

16”(

418)

1415

/16”

(379

)

28”(

711)

283/

4”(7

30)

327/

16”(

824)

3015

/16”

(786

)

123/

32”(

307)

143/

32”(

358)

183/

32”(

460)

223/

32”(

561)

243/

32”(

612)

303/

32”(

764)

363/

32”(

917)

423/

32”(

1069

)48

3/32

”(12

22)

543/

32”(

1374

)60

3/32

”(15

26)

EWC3212-3

EWC3218-3

EWC3220-3

EWC3224-3

26 3/32”(663)[3]96”(2438)

96 3/4”(2457)102 1/2”(2604)99 1/2”(2527)

EWC3228-3

EWC3230-3

EWC3236-3

EWC3242-3

EWC3248-3

EWC3254-3

EWC3260-3

EWC3266-3

EEE

EEE

EEE

EEE

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGM.O. ADAMS/FLAT CASING

M.O. BRICKMOULD

S S S S S S

ELEVATION SYMBOL LEGEND:

VALUES IN () ARE IN MILLIMETER CONVERSIONSM.O. = MASONRY OPENING

S AVAILABLE AS STATIONARY ONLY.

E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.

VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-15Architectural Detail ManualAugust 2010

SCALE 1/8” = 1’

3-WIDE UNITS

Note: Elevations shown DO NOT have exterior trim. Subtract 1/2” (12.7) from M.O. (Masonry Opening) for Unit Sizes. Masonry Openings above include SillNose, see Trim Options page for Sill Nose specifications. For other Trim Options refer to the Unit Sizing, Rough Opening & Masonry Openings page.

EWC1872-3 EWC2072-3 EWC2472-3 EWC2872-3 EWC3072-3

EWC1878-3 EWC2078-3 EWC2478-3 EWC2878-3 EWC3078-3

12 3/32”(307)[3]54”(1372)

54 3/4”(1391)60 1/2”(1537)57 1/2”(1461)

14 3/32”(358)[3] 18 3/32”(460)[3] 22 3/32”(561)[3]84”(2134)

84 3/4”(2153)90 1/2”(2299)87 1/2”(2223)

24 3/32”(612)[3]90”(2286)

90 3/4”(2305)96 1/2”(2451)93 1/2”(2375)

60”(1524)60 3/4”(1543)66 1/2”(1689)63 1/2”(1613)

72”(1829)72 3/4”(1848)78 1/2”(1994)75 1/2”(1918)

72”(

1829

)72

3/4”

(184

8)76

7/16

”(19

42)

7415

/16”

(190

3)

78”(

1981

)78

3/4”

(200

0)82

7/16

”(20

94)

8015

/16”

(205

6)

663/

32”(

1679

)72

3/32

”(18

31)

EWC3272-3

26 3/32”(663)[3]96”(2438)

96 3/4”(2457)102 1/2”(2604)99 1/2”(2527)

E E

EEE

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGM.O. ADAMS/FLAT CASING

M.O. BRICKMOULD

ELEVATION SYMBOL LEGEND:

VALUES IN () ARE IN MILLIMETER CONVERSIONSM.O. = MASONRY OPENING

E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.

VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-16Architectural Detail ManualAugust 2010

SCALE 1/8” = 1’

3-WIDE UNITS

Note: Elevations shown DO NOT have exterior trim. Subtract 1/2” (12.7) from M.O. (Masonry Opening) for Unit Sizes. Masonry Openings above include SillNose, see Trim Options page for Sill Nose specifications. For other Trim Options refer to the Unit Sizing, Rough Opening & Masonry Openings page.

ELEVATION SYMBOL LEGEND:

VALUES IN () ARE IN MILLIMETER CONVERSIONSM.O. = MASONRY OPENING

S AVAILABLE AS STATIONARY ONLY.

E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.

VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT

30 3/32”(764)[3]108”(2743)

108 3/4”(2762)114 1/2”(2908)111 1/2”(2832)

EWC3612-3

EWC3618-3

EWC3620-3

EWC3624-3

EWC3630-3

EWC3636-3

EWC3642-3

EWC3648-3

EWC3654-3

EWC3660-3

EWC3666-3

EWC3672-3

EWC3628-3

30 3/32”(764)[3]108”(2743)

108 3/4”(2762)114 1/2”(2908)111 1/2”(2832)

18”(

457)

183/

4”(4

76)

227/

16”(

570)

2015

/16”

(532

)

20”(

508)

203/

4”(5

27)

247/

16”(

621)

2215

/16”

(583

)

24”(

610)

243/

4”(6

29)

287/

16”(

722)

2615

/16”

(684

)

30”(

762)

303/

4”(7

81)

347/

16”(

875)

3215

/16”

(837

)

36”(

914)

363/

4”(9

33)

407/

16”(

1027

)38

15/1

6”(9

89)

42”(

1067

)42

3/4”

(108

6)46

7/16

”(11

80)

4415

/16”

(114

1)

48”(

1219

)48

3/4”

(123

8)52

7/16

”(13

32)

5015

/16”

(129

4)

54”(

1372

)54

3/4”

(139

1)58

7/16

”(14

84)

5615

/16”

(144

6)

60”(

1524

)60

3/4”

(154

3)64

7/16

”(16

37)

6215

/16”

(159

9)

66”(

1676

)66

3/4”

(169

5)70

7/16

”(17

89)

6815

/16”

(175

1)

63/

32”(

155)

12”(

305)

123/

4”(3

24)

167/

16”(

418)

1415

/16”

(379

)

28”(

711)

283/

4”(7

30)

327/

16”(

824)

3015

/16”

(786

)

123/

32”(

307)

143/

32”(

358)

183/

32”(

460)

223/

32”(

561)

243/

32”(

612)

303/

32”(

764)

363/

32”(

917)

423/

32”(

1069

)48

3/32

”(12

22)

543/

32”(

1374

)

603/

32”(

1526

)72

”(18

29)

723/

4”(1

848)

767/

16”(

1942

)74

15/1

6”(1

903)

663/

32”(

1679

)

E

E

E

E

E

E

E

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGM.O. ADAMS/FLAT CASING

M.O. BRICKMOULD

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGM.O. ADAMS/FLAT CASING

M.O. BRICKMOULD

S

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-17Architectural Detail ManualAugust 2010

SCALE 1/8” = 1’

4-WIDE UNITS

Note: Elevations shown DO NOT have exterior trim. Subtract 1/2” (12.7) from M.O. (Masonry Opening) for Unit Sizes. Masonry Openings above include SillNose, see Trim Options page for Sill Nose specifications. For other Trim Options refer to the Unit Sizing, Rough Opening & Masonry Openings page.

12 3/32”(307)[4] 14 3/32”(358)[4]80”(2032)

80 3/4”(2051)86 1/2”(2197)83 1/2”(2121)

18 3/32”(460)[4]96”(2438)

96 3/4”(2457)102 1/2”(2604)99 1/2”(2527)

22 3/32”(561)[4]112”(2849)

112 3/4”(2864)118 1/2”(3010)115 1/2”(2934)

24 3/32”(612)[4]120”(3048)

120 3/4”(3067)126 1/2”(3213)123 1/2”(3137)

72”(1829)72 3/4”(1848)78 1/2”(1994)75 1/2”(1918)

EWC1812-4 EWC2012-4 EWC2412-4 EWC2812-4 EWC3012-4

EWC1818-4 EWC2018-4 EWC2418-4 EWC2818-4 EWC3018-4

EWC1820-4 EWC2020-4 EWC2420-4 EWC2820-4 EWC3020-4

EWC1824-4 EWC2024-4 EWC2424-4 EWC2824-4 EWC3024-4

EWC1830-4 EWC2030-4 EWC2430-4 EWC2830-4 EWC3030-4

EWC1836-4 EWC20236-4 EWC2436-4 EWC2836-4 EWC3036-4

EWC1842-4 EWC2042-4 EWC2442-4 EWC2842-4 EWC3042-4

EWC1848-4 EWC2048-4 EWC2448-4 EWC2848-4 EWC3048-4

EWC1854-4 EWC2054-4 EWC2454-4 EWC2854-4 EWC3054-4

EWC1860-4 EWC2060-4 EWC2460-4 EWC2860-4 EWC3060-4

EWC1866-4 EWC2066-4 EWC2466-4 EWC2866-4 EWC3066-4

EWC1828-4 EWC2028-4 EWC2428-4 EWC2828-4 EWC3028-4

18”(

457)

183/

4”(4

76)

227/

16”(

570)

2015

/16”

(532

)

20”(

508)

203/

4”(5

27)

247/

16”(

621)

2215

/16”

(583

)

24”(

610)

243/

4”(6

29)

287/

16”(

722)

2615

/16”

(684

)

30”(

762)

303/

4”(7

81)

347/

16”(

875)

3215

/16”

(837

)

36”(

914)

363/

4”(9

33)

407/

16”(

1027

)38

15/1

6”(9

89)

42”(

1067

)42

3/4”

(108

6)46

7/16

”(11

80)

4415

/16”

(114

1)

48”(

1219

)48

3/4”

(123

8)52

7/16

”(13

32)

5015

/16”

(129

4)

54”(

1372

)54

3/4”

(139

1)58

7/16

”(14

84)

5615

/16”

(144

6)

60”(

1524

)60

3/4”

(154

3)64

7/16

”(16

37)

6215

/16”

(159

9)

66”(

1676

)66

3/4”

(169

5)70

7/16

”(17

89)

6815

/16”

(175

1)

63/

32”(

155)

12”(

305)

123/

4”(3

24)

167/

16”(

418)

1415

/16”

(379

)

28”(

711)

283/

4”(7

30)

327/

16”(

824)

3015

/16”

(786

)

123/

32”(

307)

143/

32”(

358)

183/

32”(

460)

223/

32”(

561)

243/

32”(

612)

303/

32”(

764)

363/

32”(

917)

423/

32”(

1069

)48

3/32

”(12

22)

543/

32”(

1374

)60

3/32

”(15

26)

E E

E E

E E

E E

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGM.O. ADAMS/FLAT CASING

M.O. BRICKMOULD

ELEVATION SYMBOL LEGEND:

VALUES IN () ARE IN MILLIMETER CONVERSIONSM.O. = MASONRY OPENING

S AVAILABLE AS STATIONARY ONLY.

E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.

VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT

S S S S S

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-18Architectural Detail ManualAugust 2010

SCALE 1/8” = 1’

4-WIDE UNITS

Note: Elevations shown DO NOT have exterior trim. Subtract 1/2” (12.7) from M.O. (Masonry Opening) for Unit Sizes. Masonry Openings above include SillNose, see Trim Options page for Sill Nose specifications. For other Trim Options refer to the Unit Sizing, Rough Opening & Masonry Openings page.

EWC1872-4 EWC2072-4 EWC2472-4 EWC2872-4 EWC3072-4

12 3/32”(307)[4] 14 3/32”(358)[4]80”(2032)

80 3/4”(2051)86 1/2”(2197)83 1/2”(2121)

18 3/32”(460)[4]96”(2438)

96 3/4”(2457)102 1/2”(2604)99 1/2”(2527)

22 3/32”(561)[4]112”(2849)

112 3/4”(2864)118 1/2”(3010)115 1/2”(2934)

24 3/32”(612)[4]120”(3048)

120 3/4”(3067)126 1/2”(3213)123 1/2”(3137)

72”(1829)72 3/4”(1848)78 1/2”(1994)75 1/2”(1918)

72”(

1829

)72

3/4”

(184

8)76

7/16

”(19

42)

7415

/16”

(190

3)

663/

32”(

1679

)

E E

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGM.O. ADAMS/FLAT CASING

M.O. BRICKMOULD

ELEVATION SYMBOL LEGEND:

VALUES IN () ARE IN MILLIMETER CONVERSIONSM.O. = MASONRY OPENING

E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.

VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-19Architectural Detail ManualAugust 2010

SCALE 1/8” = 1’

4-WIDE UNITS

30 3/32”(764)[4]144”(3658)

144 3/4”(3677)150 1/2”(3823)147 1/2”(3747)

EWC3612-4

EWC3618-4

EWC3620-4

EWC3624-4

EWC3630-4

EWC3636-4

EWC3642-4

EWC3648-4

EWC3654-4

EWC3660-4

EWC3666-4

EWC3628-4

18”(

457)

183/

4”(4

76)

227/

16”(

570)

2015

/16”

(532

)

20”(

508)

203/

4”(5

27)

247/

16”(

621)

2215

/16”

(583

)

24”(

610)

243/

4”(6

29)

287/

16”(

722)

2615

/16”

(684

)

30”(

762)

303/

4”(7

81)

347/

16”(

875)

3215

/16”

(837

)

36”(

914)

363/

4”(9

33)

407/

16”(

1027

)38

15/1

6”(9

89)

42”(

1067

)42

3/4”

(108

6)46

7/16

”(11

80)

4415

/16”

(114

1)

48”(

1219

)48

3/4”

(123

8)52

7/16

”(13

32)

5015

/16”

(129

4)

54”(

1372

)54

3/4”

(139

1)58

7/16

”(14

84)

5615

/16”

(144

6)

60”(

1524

)60

3/4”

(154

3)64

7/16

”(16

37)

6215

/16”

(159

9)

66”(

1676

)66

3/4”

(169

5)70

7/16

”(17

89)

6815

/16”

(175

1)

63/

32”(

155)

12”(

305)

123/

4”(3

24)

167/

16”(

418)

1415

/16”

(379

)

28”(

711)

283/

4”(7

30)

327/

16”(

824)

3015

/16”

(786

)

123/

32”(

307)

143/

32”(

358)

183/

32”(

460)

223/

32”(

561)

243/

32”(

612)

303/

32”(

764)

363/

32”(

917)

423/

32”(

1069

)48

3/32

”(12

22)

543/

32”(

1374

)60

3/32

”(15

26)

E

E

E

E

E

E

EWC3254-4

EWC3260-4

EWC3266-4

EWC3248-4

EWC3242-4

EWC3230-4

EWC3236-4

EWC3224-4

EWC3228-4

EWC3218-4

EWC3220-4

EWC3212-4

26 3/32”(663)[4]128”(3251)

128 3/4”(3270)134 1/2”(3416)131 1/2”(3340)

E

E

E

E

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGM.O. ADAMS/FLAT CASING

M.O. BRICKMOULD

Note: Elevations shown DO NOT have exterior trim. Subtract 1/2” (12.7) from M.O. (Masonry Opening) for Unit Sizes. Masonry Openings above include SillNose, see Trim Options page for Sill Nose specifications. For other Trim Options refer to the Unit Sizing, Rough Opening & Masonry Openings page.

ELEVATION SYMBOL LEGEND:

VALUES IN () ARE IN MILLIMETER CONVERSIONSM.O. = MASONRY OPENING

E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.

VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT

SS

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-20Architectural Detail ManualAugust 2010

SCALE 1/8” = 1’

4-WIDE UNITS

Note: Elevations shown DO NOT have exterior trim. Subtract 1/2” (12.7) from M.O. (Masonry Opening) for Unit Sizes. Masonry Openings above include SillNose, see Trim Options page for Sill Nose specifications. For other Trim Options refer to the Unit Sizing, Rough Opening & Masonry Openings page.

ELEVATION SYMBOL LEGEND:

VALUES IN () ARE IN MILLIMETER CONVERSIONSM.O. = MASONRY OPENING

E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.

VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT

EWC3672-4

30 3/32”(764)[4]144”(3658)

144 3/4”(3677)150 1/2”(3823)147 1/2”(3747)

72”(

1829

)72

3/4”

(184

8)76

7/16

”(19

42)

7415

/16”

(190

3)

663/

32”(

1679

)E

EWC3272-4

26 3/32”(663)[4]128”(3251)

128 3/4”(3270)134 1/2”(3416)131 1/2”(3340)

E

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGM.O. ADAMS/FLAT CASING

M.O. BRICKMOULD

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-21Architectural Detail ManualAugust 2010

SCALE 1/8” = 1’

5-WIDE UNITS

Note: Elevations shown DO NOT have exterior trim. Subtract 1/2” (12.7) from M.O. (Masonry Opening) for Unit Sizes. Masonry Openings above include SillNose, see Trim Options page for Sill Nose specifications. For other Trim Options refer to the Unit Sizing, Rough Opening & Masonry Openings page.

12 3/32”(307)[5]90”(2286)

90 3/4”(2305)96 1/2”(2451)93 1/2”(2380)

14 3/32”(358)[5]100”(2540)

100 3/4”(2559)106 1/2”(2705)103 1/2”(2629)

18 3/32”(460)[5]120”(3048)

120 3/4”(3067)126 1/2”(3213)123 1/2”(3137)

22 3/32”(561)[5]140”(3556)

140 3/4”(3575)146 1/2”(3721)143 1/2”(3645)

EWC1812-5 EWC2012-5 EWC2412-5 EWC2812-5

EWC1818-5 EWC2018-5 EWC2418-5 EWC2818-5

EWC1820-5 EWC2020-5 EWC2420-5 EWC2820-5

EWC1824-5 EWC2024-5 EWC2424-5 EWC2824-5

EWC1830-5 EWC2030-5 EWC2430-5 EWC2830-5

EWC1836-5 EWC2036-5 EWC2436-5 EWC2836-5

EWC1842-5 EWC2042-5 EWC2442-5 EWC2842-5

EWC1848-5 EWC2048-5 EWC2448-5 EWC2848-5

EWC1854-5 EWC2054-5 EWC2454-5 EWC2854-5

EWC1860-5 EWC2060-5 EWC2460-5 EWC2860-5

EWC1866-5 EWC2066-5 EWC2466-5 EWC2866-5

EWC1828-5 EWC2028-5 EWC2428-5 EWC2828-5

18”(

457)

183/

4”(4

76)

227/

16”(

570)

2015

/16”

(532

)

20”(

508)

203/

4”(5

27)

247/

16”(

621)

2215

/16”

(583

)

24”(

610)

243/

4”(6

29)

287/

16”(

722)

2615

/16”

(684

)

30”(

762)

303/

4”(7

81)

347/

16”(

875)

3215

/16”

(837

)

36”(

914)

363/

4”(9

33)

407/

16”(

1027

)38

15/1

6”(9

89)

42”(

1067

)42

3/4”

(108

6)46

7/16

”(11

80)

4415

/16”

(114

1)

48”(

1219

)48

3/4”

(123

8)52

7/16

”(13

32)

5015

/16”

(129

4)

54”(

1372

)54

3/4”

(139

1)58

7/16

”(14

84)

5615

/16”

(144

6)

60”(

1524

)60

3/4”

(154

3)64

7/16

”(16

37)

6215

/16”

(159

9)

66”(

1676

)66

3/4”

(169

5)70

7/16

”(17

89)

6815

/16”

(175

1)

63/

32”(

155)

12”(

305)

123/

4”(3

24)

167/

16”(

418)

1415

/16”

(379

)

28”(

711)

283/

4”(7

30)

327/

16”(

824)

3015

/16”

(786

)

123/

32”(

307)

143/

32”(

358)

183/

32”(

460)

223/

32”(

561)

243/

32”(

612)

303/

32”(

764)

363/

32”(

917)

423/

32”(

1069

)48

3/32

”(12

22)

543/

32”(

1374

)60

3/32

”(15

26)

E

E

E

E

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGM.O. ADAMS/FLAT CASING

M.O. BRICKMOULD

S S S S

ELEVATION SYMBOL LEGEND:

VALUES IN () ARE IN MILLIMETER CONVERSIONSM.O. = MASONRY OPENING

S AVAILABLE AS STATIONARY ONLY.

E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.

VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-22Architectural Detail ManualAugust 2010

SCALE 1/8” = 1’

5-WIDE UNITS

Note: Elevations shown DO NOT have exterior trim. Subtract 1/2” (12.7) from M.O. (Masonry Opening) for Unit Sizes. Masonry Openings above include SillNose, see Trim Options page for Sill Nose specifications. For other Trim Options refer to the Unit Sizing, Rough Opening & Masonry Openings page.

EWC1872-5 EWC2072-5 EWC2472-5 EWC2872-5

12 3/32”(307)[5]90”(2286)

90 3/4”(2305)96 1/2”(2451)93 1/2”(2380)

14 3/32”(358)[5]100”(2540)

100 3/4”(2559)106 1/2”(2705)103 1/2”(2629)

18 3/32”(460)[5]120”(3048)

120 3/4”(3067)126 1/2”(3213)123 1/2”(3137)

22 3/32”(561)[5]140”(3556)

140 3/4”(3575)146 1/2”(3721)143 1/2”(3645)

72”(

1829

)72

3/4”

(184

8)76

7/16

”(19

42)

7415

/16”

(190

3)

663/

32”(

1679

)

E

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGM.O. ADAMS/FLAT CASING

M.O. BRICKMOULD

ELEVATION SYMBOL LEGEND:

VALUES IN () ARE IN MILLIMETER CONVERSIONSM.O. = MASONRY OPENING

E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.

VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-23Architectural Detail ManualAugust 2010

SCALE 1/8” = 1’

5-WIDE UNITS

Note: Elevations shown DO NOT have exterior trim. Subtract 1/2” (12.7) from M.O. (Masonry Opening) for Unit Sizes. Masonry Openings above include SillNose, see Trim Options page for Sill Nose specifications. For other Trim Options refer to the Unit Sizing, Rough Opening & Masonry Openings page.

24 3/32”(612)[5]150”(3810)

150 3/4”(3829)156 1/2”(3975)153 1/2”(3899)

30 3/32”(764)[5]180”(4572)

180 3/4”(4591)186 1/2”(4737)183 1/2”(4661)

EWC3012-5 EWC3612-5

EWC3018-5 EWC3618-5

EWC3020-5 EWC3620-5

EWC3024-5

EWC3030-5 EWC3630-5

EWC3036-5 EWC3636-5

EWC3042-5 EWC3642-5

EWC3048-5 EWC3648-5

EWC3054-5 EWC3654-5

EWC3060-5 EWC3660-5

EWC3066-5 EWC3666-5

EWC3624-5

EWC3028-5 EWC3628-5

18”(

457)

183/

4”(4

76)

227/

16”(

570)

2015

/16”

(532

)

20”(

508)

203/

4”(5

27)

247/

16”(

621)

2215

/16”

(583

)

24”(

610)

243/

4”(6

29)

287/

16”(

722)

2615

/16”

(684

)

30”(

762)

303/

4”(7

81)

347/

16”(

875)

3215

/16”

(837

)

36”(

914)

363/

4”(9

33)

407/

16”(

1027

)38

15/1

6”(9

89)

42”(

1067

)42

3/4”

(108

6)46

7/16

”(11

80)

4415

/16”

(114

1)

48”(

1219

)48

3/4”

(123

8)52

7/16

”(13

32)

5015

/16”

(129

4)

54”(

1372

)54

3/4”

(139

1)58

7/16

”(14

84)

5615

/16”

(144

6)

60”(

1524

)60

3/4”

(154

3)64

7/16

”(16

37)

6215

/16”

(159

9)

66”(

1676

)66

3/4”

(169

5)70

7/16

”(17

89)

6815

/16”

(175

1)

63/

32”(

155)

12”(

305)

123/

4”(3

24)

167/

16”(

418)

1415

/16”

(379

)

28”(

711)

283/

4”(7

30)

327/

16”(

824)

3015

/16”

(786

)

123/

32”(

307)

143/

32”(

358)

183/

32”(

460)

223/

32”(

561)

243/

32”(

612)

303/

32”(

764)

363/

32”(

917)

423/

32”(

1069

)48

3/32

”(12

22)

543/

32”(

1374

)60

3/32

”(15

26)

EWC3212-5

EWC3218-5

EWC3220-5

EWC3224-5

EWC3230-5

EWC3236-5

EWC3242-5

EWC3248-5

EWC3254-5

EWC3260-5

EWC3266-5

EWC3228-5

26 3/32”(663)[5]160”(4064)

160 3/4”(4083)166 1/2”(4229)163 1/2”(4153)

E E E

E

E

E E E

E E E

E E E

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGM.O. ADAMS/FLAT CASING

M.O. BRICKMOULD

ELEVATION SYMBOL LEGEND:

VALUES IN () ARE IN MILLIMETER CONVERSIONSM.O. = MASONRY OPENING

S AVAILABLE AS STATIONARY ONLY.

E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.

VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT

S S S

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-24Architectural Detail ManualAugust 2010

SCALE 1/8” = 1’

5-WIDE UNITS

Note: Elevations shown DO NOT have exterior trim. Subtract 1/2” (12.7) from M.O. (Masonry Opening) for Unit Sizes. Masonry Openings above include SillNose, see Trim Options page for Sill Nose specifications. For other Trim Options refer to the Unit Sizing, Rough Opening & Masonry Openings page.

EWC3072-5 EWC3672-5

24 3/32”(612)[5]150”(3810)

150 3/4”(3829)156 1/2”(3975)153 1/2”(3899)

30 3/32”(764)[5]180”(4572)

180 3/4”(4591)186 1/2”(4737)183 1/2”(4661)

72”(

1829

)72

3/4”

(184

8)76

7/16

”(19

42)

7415

/16”

(190

3)

663/

32”(

1679

)

EWC3272-5

26 3/32”(663)[5]160”(4064)

160 3/4”(4083)166 1/2”(4229)163 1/2”(4153)

E E E

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGM.O. ADAMS/FLAT CASING

M.O. BRICKMOULD

ELEVATION SYMBOL LEGEND:

VALUES IN () ARE IN MILLIMETER CONVERSIONSM.O. = MASONRY OPENING

E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.

VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-25Architectural Detail ManualAugust 2010

SCALE 1/4” = 1’

PICTURE UNITS

Note: Elevations shown DO NOT have exterior trim. Subtract 1/2” (12.7) from M.O. (Masonry Opening) for Unit Sizes. Masonry Openings above include Sill Nose, seeTrim Options page for Sill Nose specifications. For other Trim Options refer to the Unit Sizing, Rough Opening & Masonry Openings page.

36 3/32”(917)42”(1067)

42 3/4”(1086)48 1/2”(1232)45 1/2”(1156)

42 3/32”(1069)48”(1219)

48 3/4”(1238)54 1/2”(1384)51 1/2”(1308)

48 3/32”(1222)54”(1372)

54 3/4”(1391)60 1/2”(1537)57 1/2”(1461)

EWCP4212 EWCP4812 EWCP5412 EWCP6012

EWCP4218 EWCP4818 EWCP5418 EWCP6018

EWCP4220 EWCP4820 EWCP5420 EWCP6020

EWCP4224 EWCP4824 EWCP5424 EWCP6024

EWCP4230 EWCP4830 EWCP5430 EWCP6030

EWCP4236 EWCP4836 EWCP5436 EWCP6036

EWCP4242 EWCP4842 EWCP5442 EWCP6042

EWCP4248 EWCP4848 EWCP5448 EWCP6048

EWCP4228 EWCP4828 EWCP5428 EWCP6028

18”(

457)

183/

4”(4

76)

227/

16”(

570)

2015

/16”

(532

)

20”(

508)

203/

4”(5

27)

247/

16”(

621)

2215

/16”

(583

)

24”(

610)

243/

4”(6

29)

287/

16”(

722)

2615

/16”

(684

)

30”(

762)

303/

4”(7

81)

347/

16”(

875)

3215

/16”

(837

)

36”(

914)

363/

4”(9

33)

407/

16”(

1027

)38

15/1

6”(9

89)

42”(

1067

)42

3/4”

(108

6)46

7/16

”(11

80)

4415

/16”

(114

1)

48”(

1219

)48

3/4”

(123

8)52

7/16

”(13

32)

5015

/16”

(129

4)

63/

32”(

155)

12”(

305)

123/

4”(3

24)

167/

16”(

418)

1415

/16”

(379

)

28”(

711)

283/

4”(7

30)

123/

32”(

307)

143/

32”(

358)

183/

32”(

460)

223/

32”(

561)

243/

32”(

612)

303/

32”(

764)

363/

32”(

917)

423/

32”(

1069

)

327/

16”(

824)

3015

/16”

(786

)

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGM.O. ADAMS/FLAT CASING

M.O. BRICKMOULD

ELEVATION SYMBOL LEGEND:

VALUES IN () ARE IN MILLIMETER CONVERSIONSM.O. = MASONRY OPENING

##** INDICATES OPTIONAL DESIGN PRESSURE (DP) RATING##* INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

54 3/32”(1374)60”(1524)

60 3/4”(1543)66 1/2”(1689)63 1/2”(1613)

50**35*

50**35*

50**35*

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-26Architectural Detail ManualAugust 2010

SCALE 1/4” = 1’

PICTURE UNITS

Note: Elevations shown DO NOT have exterior trim. Subtract 1/2” (12.7) from M.O. (Masonry Opening) for Unit Sizes.Masonry Openings above include Sill Nose, see Trim Options page for Sill Nose specifications. For other TrimOptions refer to the Unit Sizing, Rough Opening & Masonry Openings page.

EWCP4254 EWCP4854 EWCP5454 EWCP6054

EWCP4260 EWCP4860 EWCP5460 EWCP6060

EWCP4266 EWCP4866 EWCP5466 EWCP6066

EWCP4272 EWCP4872 EWCP5472 EWCP6072

EWCP4278 EWCP4878 EWCP5478 EWCP6078

36 3/32”(917)42”(1067)

42 3/4”(1086)48 1/2”(1232)45 1/2”(1156)

42 3/32”(1069)48”(1219)

48 3/4”(1238)54 1/2”(1384)51 1/2”(1308)

48 3/32”(1222)54”(1372)

54 3/4”(1391)60 1/2”(1537)57 1/2”(1461)

54 3/32”(1374)60”(1524)

60 3/4”(1543)66 1/2”(1689)63 1/2”(1613)

54”(

1372

)54

3/4”

(139

1)58

7/16

”(14

84)

5615

/16”

(144

6)

60”(

1524

)60

3/4”

(154

3)64

7/16

”(16

37)

6215

/16”

(159

9)

66”(

1676

)66

3/4”

(169

5)70

7/16

”(17

89)

6815

/16”

(175

1)

72”(

1829

)72

3/4”

(184

8)76

7/16

”(19

42)

7415

/16”

(190

3)

78”(

1981

)78

3/4”

(200

0)82

7/16

”(20

94)

8015

/16”

(205

6)

483/

32”(

1222

)54

3/32

”(13

74)

603/

32”(

1526

)66

3/32

”(16

79)

723/

32”(

1831

)

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGM.O. ADAMS/FLAT CASING

M.O. BRICKMOULD

ELEVATION SYMBOL LEGEND:

VALUES IN () ARE IN MILLIMETER CONVERSIONSM.O. = MASONRY OPENING

##** INDICATES OPTIONAL DESIGN PRESSURE (DP) RATING##* INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-27Architectural Detail ManualAugust 2010

SCALE 1/4” = 1’

PICTURE UNITS

Note: Elevations shown DO NOT have exterior trim. Subtract 1/2” (12.7) from M.O. (Masonry Opening) for Unit Sizes. Masonry Openings above include Sill Nose, seeTrim Options page for Sill Nose specifications. For other Trim Options refer to the Unit Sizing, Rough Opening & Masonry Openings page.

EWCP4284 EWCP4884 EWCP5484 EWCP6084

36 3/32”(917)42”(1067)

42 3/4”(1086)48 1/2”(1232)45 1/2”(1156)

42 3/32”(1069)48”(1219)

48 3/4”(1238)54 1/2”(1384)51 1/2”(1308)

48 3/32”(1222)54”(1372)

54 3/4”(1391)60 1/2”(1537)57 1/2”(1461)

54 3/32”(1374)60”(1524)

60 3/4”(1543)66 1/2”(1689)63 1/2”(1613)

84”(

2134

)84

3/4”

(215

3)88

7/16

”(22

46)

8615

/16”

(220

8)

783/

32”(

1984

)

EWCP4296 EWCP4896 EWCP5496 EWCP6096

96”(

2438

)96

3/4”

(245

7)10

07/

16”(

2551

)98

15/1

6”(2

513)

903/

32”(

2288

)DAYLIGHT OPENING

FRAME SIZEROUGH OPENING

M.O. ADAMS/FLAT CASINGM.O. BRICKMOULD

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

ELEVATION SYMBOL LEGEND:

VALUES IN () ARE IN MILLIMETER CONVERSIONSM.O. = MASONRY OPENING

##** INDICATES OPTIONAL DESIGN PRESSURE (DP) RATING##* INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-28Architectural Detail ManualAugust 2010

SCALE 1/4” = 1’

PICTURE UNITS

Note: Elevations shown DO NOT have exterior trim. Subtract 1/2” (12.7) from M.O. (Masonry Opening) for Unit Sizes. Masonry Openings above include SillNose, see Trim Options page for Sill Nose specifications. For other Trim Options refer to the Unit Sizing, Rough Opening & Masonry Openings page.

60 3/32”(1526)66”(1676)

66 3/4”(1695)72 1/2”(1842)69 1/2”(1765)

66 3/32”(1679)72”(1829)

72 3/4”(1848)78 1/2”(1994)75 1/2”(1918)

EWCP6612 EWCP7212

EWCP6618 EWCP7218

EWCP6620 EWCP7220

EWCP6624 EWCP7224

EWCP6630 EWCP7230

EWCP6636 EWCP7236

EWCP6642 EWCP7242

EWCP6648 EWCP7248

EWCP6628 EWCP7228

18”(

457)

183/

4”(4

76)

227/

16”(

570)

2015

/16”

(532

)

20”(

508)

203/

4”(5

27)

247/

16”(

621)

2215

/16”

(583

)

24”(

610)

243/

4”(6

29)

287/

16”(

722)

2615

/16”

(684

)

30”(

762)

303/

4”(7

81)

347/

16”(

875)

3215

/16”

(837

)

36”(

914)

363/

4”(9

33)

407/

16”(

1027

)38

15/1

6”(9

89)

42”(

1067

)42

3/4”

(108

6)46

7/16

”(11

80)

4415

/16”

(114

1)

48”(

1219

)48

3/4”

(123

8)52

7/16

”(13

32)

5015

/16”

(129

4)

63/

32”(

155)

12”(

305)

123/

4”(3

24)

167/

16”(

418)

1415

/16”

(379

)

28”(

711)

283/

4”(7

30)

123/

32”(

307)

143/

32”(

358)

183/

32”(

460)

223/

32”(

561)

243/

32”(

612)

303/

32”(

764)

363/

32”(

917)

423/

32”(

1069

)

327/

16”(

824)

3015

/16”

(786

)

EWCP8412

EWCP8418

EWCP8420

EWCP8424

EWCP8430

EWCP8436

EWCP8442

EWCP8448

EWCP8428

78 3/32”(1984)84”(2134)

84 3/4”(2153)90 1/2”(2299)87 1/2”(2223)

ELEVATION SYMBOL LEGEND:

VALUES IN () ARE IN MILLIMETER CONVERSIONSM.O. = MASONRY OPENING

##** INDICATES OPTIONAL DESIGN PRESSURE (DP) RATING##* INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGM.O. ADAMS/FLAT CASING

M.O. BRICKMOULD

50**35*

50**35*

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-29Architectural Detail ManualAugust 2010

SCALE 1/4” = 1’

PICTURE UNITS

Note: Elevations shown DO NOT have exterior trim. Subtract 1/2” (12.7) from M.O. (Masonry Opening) for UnitSizes. Masonry Openings above include Sill Nose, see Trim Options page for Sill Nose specifications. Forother Trim Options refer to the Unit Sizing, Rough Opening & Masonry Openings page.

EWCP6654 EWCP7254

EWCP6660 EWCP7260

EWCP6666 EWCP7266

EWCP6672 EWCP7272

EWCP6678 EWCP7278

60 3/32”(1526)66”(1676)

66 3/4”(1695)72 1/2”(1842)69 1/2”(1765)

66 3/32”(1679)72”(1829)

72 3/4”(1848)78 1/2”(1994)75 1/2”(1918)

54”(

1372

)54

3/4”

(139

1)58

7/16

”(14

84)

5615

/16”

(144

6)

60”(

1524

)60

3/4”

(154

3)64

7/16

”(16

37)

6215

/16”

(159

9)

66”(

1676

)66

3/4”

(169

5)70

7/16

”(17

89)

6815

/16”

(175

1)

72”(

1829

)72

3/4”

(184

8)76

7/16

”(19

42)

7415

/16”

(190

3)

78”(

1981

)78

3/4”

(200

0)82

7/16

”(20

94)

8015

/16”

(205

6)

483/

32”(

1222

)54

3/32

”(13

74)

603/

32”(

1526

)66

3/32

”(16

79)

723/

32”(

1831

)

EWCP8454

EWCP8460

EWCP8466

EWCP8472

EWCP8478

78 3/32”(1984)84”(2134)

84 3/4”(2153)90 1/2”(2299)87 1/2”(2223)

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGM.O. ADAMS/FLAT CASING

M.O. BRICKMOULD

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35* 35* 35*

ELEVATION SYMBOL LEGEND:

VALUES IN () ARE IN MILLIMETER CONVERSIONSM.O. = MASONRY OPENING

##** INDICATES OPTIONAL DESIGN PRESSURE (DP) RATING##* INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-30Architectural Detail ManualAugust 2010

SCALE 1/4” = 1’

PICTURE UNITS

Note: Elevations shown DO NOT have exterior trim. Subtract 1/2” (12.7) from M.O. (Masonry Opening) for Unit Sizes. Masonry Openings above include SillNose, see Trim Options page for Sill Nose specifications. For other Trim Options refer to the Unit Sizing, Rough Opening & Masonry Openings page.

EWCP6684 EWCP7284

60 3/32”(1526)66”(1676)

66 3/4”(1695)72 1/2”(1842)69 1/2”(1765)

66 3/32”(1679)72”(1829)

72 3/4”(1848)78 1/2”(1994)75 1/2”(1918)

84”(

2134

)84

3/4”

(215

3)88

7/16

”(22

46)

8615

/16”

(220

8)

783/

32”(

1984

)

EWCP6696 EWCP7296

96”(

2438

)96

3/4”

(245

7)10

07/

16”(

2551

)98

15/1

6”(2

513)

903/

32”(

2288

)

EWCP8484

78 3/32”(1984)84”(2134)

84 3/4”(2153)90 1/2”(2299)87 1/2”(2223)

50**35* 35* 35*

50**35* 35*

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGM.O. ADAMS/FLAT CASING

M.O. BRICKMOULD

ELEVATION SYMBOL LEGEND:

VALUES IN () ARE IN MILLIMETER CONVERSIONSM.O. = MASONRY OPENING

##** INDICATES OPTIONAL DESIGN PRESSURE (DP) RATING##* INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-31Architectural Detail ManualAugust 2010

SCALE 1/4” = 1’

PICTURE UNITS

Note: Elevations shown DO NOT have exterior trim. Subtract 1/2” (12.7) from M.O. (Masonry Opening) for Unit Sizes. Masonry Openings above include SillNose, see Trim Options page for Sill Nose specifications. For other Trim Options refer to the Unit Sizing, Rough Opening & Masonry Openings page.

ELEVATION SYMBOL LEGEND:

VALUES IN () ARE IN MILLIMETER CONVERSIONSM.O. = MASONRY OPENING

##** INDICATES OPTIONAL DESIGN PRESSURE (DP) RATING##* INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING

EWCP9654

EWCP9660

EWCP9666

EWCP9672

EWCP9612

EWCP9618

EWCP9620

EWCP9624

EWCP9630

EWCP9636

EWCP9642

EWCP9648

EWCP9628

90 3/32”(2288)96”(2438)

96 3/4”(2457)102 1/2”(2604)99 1/2”(2527)

90 3/32”(2288)96”(2438)

96 3/4”(2457)102 1/2”(2604)99 1/2”(2527)

18”(

457)

183/

4”(4

76)

227/

16”(

570)

2015

/16”

(532

)

20”(

508)

203/

4”(5

27)

247/

16”(

621)

2215

/16”

(583

)

24”(

610)

243/

4”(6

29)

287/

16”(

722)

2615

/16”

(684

)

30”(

762)

303/

4”(7

81)

347/

16”(

875)

3215

/16”

(837

)

36”(

914)

363/

4”(9

33)

407/

16”(

1027

)38

15/1

6”(9

89)

42”(

1067

)42

3/4”

(108

6)46

7/16

”(11

80)

4415

/16”

(114

1)

48”(

1219

)48

3/4”

(123

8)52

7/16

”(13

32)

5015

/16”

(129

4)

63/

32”(

155)

12”(

305)

123/

4”(3

24)

167/

16”(

418)

1415

/16”

(379

)

28”(

711)

283/

4”(7

30)

123/

32”(

307)

143/

32”(

358)

183/

32”(

460)

223/

32”(

561)

243/

32”(

612)

303/

32”(

764)

363/

32”(

917)

423/

32”(

1069

)

327/

16”(

824)

3015

/16”

(786

)

54”(

1372

)54

3/4”

(139

1)58

7/16

”(14

84)

5615

/16”

(144

6)

60”(

1524

)60

3/4”

(154

3)64

7/16

”(16

37)

6215

/16”

(159

9)

66”(

1676

)66

3/4”

(169

5)70

7/16

”(17

89)

6815

/16”

(175

1)

72”(

1829

)72

3/4”

(184

8)76

7/16

”(19

42)

7415

/16”

(190

3)

483/

32”(

1222

)54

3/32

”(13

74)

603/

32”(

1526

)66

3/32

”(16

79)

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGM.O. ADAMS/FLAT CASING

M.O. BRICKMOULD

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGM.O. ADAMS/FLAT CASING

M.O. BRICKMOULD

50**35*

35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

50**35*

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-32Architectural Detail ManualAugust 2010

SCALE 1/8” = 1’

PICTURE UNITS WITH 18” FLANKERS

Note: Elevations shown DO NOT have exterior trim. Subtract 1/2” (12.7) from M.O. (Masonry Opening) for Unit Sizes. Masonry Openings above include SillNose, see Trim Options page for Sill Nose specifications. For other Trim Options refer to the Unit Sizing, Rough Opening & Masonry Openings page.

12 3/32”(307)[2] 36 3/32”(917)78”(1981)

78 3/4”(2000)84 1/2”(2146)81 1/2”(2070)

EWCP4242-18 EWCP5442-18 EWCP6642-18

12 3/32”(307)[2] 48 3/32”(1222)90”(2286)

90 3/4”(2305)96 1/2”(2451)93 1/2”(2375)

12 3/32”(307)[2] 60 3/32”(1526)102”(2591)

102 3/4”(2610)108 1/2”(2756)105 1/2”(2680)

EWCP4248-18 EWCP5448-18 EWCP6648-18

EWCP4254-18 EWCP5454-18 EWCP6654-18

EWCP4260-18 EWCP5460-18 EWCP6660-18

EWCP4266-18 EWCP5466-18 EWCP6666-18

42”(

1067

)42

3/4”

(108

6)46

7/16

”(11

80)

4415

/16”

(114

1)

48”(

1219

)48

3/4”

(123

8)52

7/16

”(13

32)

5015

/16”

(129

4)

54”(

1372

)54

3/4”

(139

1)58

7/16

”(14

84)

5615

/16”

(144

6)

60”(

1524

)60

3/4”

(154

3)64

7/16

”(16

37)

6215

/16”

(159

9)

66”(

1676

)66

3/4”

(169

5)70

7/16

”(17

89)

6815

/16”

(175

1)

363/

32”(

917)

423/

32”(

1069

)48

3/32

”(12

22)

543/

32”(

1374

)60

3/32

”(15

26)

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGM.O. ADAMS/FLAT CASING

M.O. BRICKMOULD

ELEVATION SYMBOL LEGEND:

VALUES IN () ARE IN MILLIMETER CONVERSIONSM.O. = MASONRY OPENING

VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-33Architectural Detail ManualAugust 2010

SCALE 1/8” = 1’

PICTURE UNITS WITH 20” FLANKERS

Note: Elevations shown DO NOT have exterior trim. Subtract 1/2” (12.7) from M.O. (Masonry Opening) for Unit Sizes. Masonry Openings above include Sill Nose,see Trim Options page for Sill Nose specifications. For other Trim Options refer to the Unit Sizing, Rough Opening & Masonry Openings page.

14 3/32”(358)[2] 36 3/32”(917)82”(2083)

82 3/4”(2102)88 1/2”(2248)85 1/2”(2172)

EWCP4242-20 EWCP5442-20 EWCP6642-20

EWCP4248-20 EWCP5448-20 EWCP6648-20

EWCP4254-20 EWCP5454-20 EWCP6654-20

EWCP4260-20 EWCP5460-20 EWCP6660-20

EWCP4266-20 EWCP5466-20 EWCP6666-20

14 3/32”(358)[2] 48 3/32”(1222)94”(2388)

94 3/4”(2407)100 1/2”(2553)97 1/2”(2477)

14 3/32”(358)[2] 60 3/32”(1526)106”(2692)

106 3/4”(2711)112 1/2”(2858)109 1/2”(2781)

42”(

1067

)42

3/4”

(108

6)46

7/16

”(11

80)

4415

/16”

(114

1)

48”(

1219

)48

3/4”

(123

8)52

7/16

”(13

32)

5015

/16”

(129

4)

54”(

1372

)54

3/4”

(139

1)58

7/16

”(14

84)

5615

/16”

(144

6)

60”(

1524

)60

3/4”

(154

3)64

7/16

”(16

37)

6215

/16”

(159

9)

66”(

1676

)66

3/4”

(169

5)70

7/16

”(17

89)

6815

/16”

(175

1)

363/

32”(

917)

423/

32”(

1069

)48

3/32

”(12

22)

543/

32”(

1374

)60

3/32

”(15

26)

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGM.O. ADAMS/FLAT CASING

M.O. BRICKMOULD

ELEVATION SYMBOL LEGEND:

VALUES IN () ARE IN MILLIMETER CONVERSIONSM.O. = MASONRY OPENING

VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-34Architectural Detail ManualAugust 2010

SCALE 1/8” = 1’

PICTURE UNITS WITH 24” FLANKERS

Note: Elevations shown DO NOT have exterior trim. Subtract 1/2” (12.7) from M.O. (Masonry Opening) for Unit Sizes. Masonry Openings above include SillNose, see Trim Options page for Sill Nose specifications. For other Trim Options refer to the Unit Sizing, Rough Opening & Masonry Openings page.

EWCP4242-24 EWCP5442-24 EWCP6642-24

18 3/32”(460)[2] 36 3/32”(917)90”(2286)

90 3/4”(2305)96 1/2”(2451)93 1/2”(2375)

18 3/32”(460)[2] 48 3/32”(1222)102”(2591)

102 3/4”(2610)108 1/2”(2756)105 1/2”(2680)

18 3/32”(460)[2] 60 3/32”(1526)114”(2896)

114 3/4”(2915)120 1/2”(3061)117 1/2”(2985)

42”(

1067

)42

3/4”

(108

6)46

7/16

”(11

80)

4415

/16”

(114

1)

48”(

1219

)48

3/4”

(123

8)52

7/16

”(13

32)

5015

/16”

(129

4)

54”(

1372

)54

3/4”

(139

1)58

7/16

”(14

84)

5615

/16”

(144

6)

60”(

1524

)60

3/4”

(154

3)64

7/16

”(16

37)

6215

/16”

(159

9)

66”(

1676

)66

3/4”

(169

5)70

7/16

”(17

89)

6815

/16”

(175

1)

363/

32”(

917)

423/

32”(

1069

)48

3/32

”(12

22)

543/

32”(

1374

)60

3/32

”(15

26)

EWCP4248-24 EWCP5448-24 EWCP6648-24

EWCP4254-24 EWCP5454-24 EWCP6654-24

EWCP4260-24 EWCP5460-24 EWCP6660-24

EWCP4266-24 EWCP5466-24 EWCP6666-24

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGM.O. ADAMS/FLAT CASING

M.O. BRICKMOULD

ELEVATION SYMBOL LEGEND:

VALUES IN () ARE IN MILLIMETER CONVERSIONSM.O. = MASONRY OPENING

VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-35Architectural Detail ManualAugust 2010

SCALE 1/8” = 1’

PICTURE UNITS WITH 28” FLANKERS

Note: Elevations shown DO NOT have exterior trim. Subtract 1/2” (12.7) from M.O. (Masonry Opening) for Unit Sizes. Masonry Openings above include SillNose, see Trim Options page for Sill Nose specifications. For other Trim Options refer to the Unit Sizing, Rough Opening & Masonry Openings page.

22 3/32”(561)[2] 36 3/32”(917)98”(2489)

98 3/4”(2508)104 1/2”(2654)101 1/2”(2578)

EWCP4242-28 EWCP5442-28 EWCP6642-28

22 3/32”(561)[2] 48 3/32”(1222)110”(2794)

110 3/4”(2813)116 1/2”(2959)113 1/2”(2883)

22 3/32”(561)[2] 60 3/32”(1526)122”(3099)

122 3/4”(3118)128 1/2”(3264)125 1/2”(3188)

42”(

1067

)42

3/4”

(108

6)46

7/16

”(11

80)

4415

/16”

(114

1)

48”(

1219

)48

3/4”

(123

8)52

7/16

”(13

32)

5015

/16”

(129

4)

54”(

1372

)54

3/4”

(139

1)58

7/16

”(14

84)

5615

/16”

(144

6)

60”(

1524

)60

3/4”

(154

3)64

7/16

”(16

37)

6215

/16”

(159

9)

66”(

1676

)66

3/4”

(169

5)70

7/16

”(17

89)

6815

/16”

(175

1)

363/

32”(

917)

423/

32”(

1069

)48

3/32

”(12

22)

543/

32”(

1374

)60

3/32

”(15

26)

EWCP4248-28 EWCP5448-28 EWCP6648-28

EWCP4254-28 EWCP5454-28 EWCP6654-28

EWCP4260-28 EWCP5460-28 EWCP6660-28

EWCP4266-28 EWCP5466-28 EWCP6666-28

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGM.O. ADAMS/FLAT CASING

M.O. BRICKMOULD

ELEVATION SYMBOL LEGEND:

VALUES IN () ARE IN MILLIMETER CONVERSIONSM.O. = MASONRY OPENING

VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-36Architectural Detail ManualAugust 2010

SCALE 1/8” = 1’

PICTURE UNITS WITH 30” FLANKERS

Note: Elevations shown DO NOT have exterior trim. Subtract 1/2” (12.7) from M.O. (Masonry Opening) for Unit Sizes. Masonry Openings above include SillNose, see Trim Options page for Sill Nose specifications. For other Trim Options refer to the Unit Sizing, Rough Opening & Masonry Openings page.

VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT

ELEVATION SYMBOL LEGEND:

VALUES IN () ARE IN MILLIMETER CONVERSIONSM.O. = MASONRY OPENING

24 3/32”(612)[2] 36 3/32”(917)102”(2591)

102 3/4”(2610)108 1/2”(2756)105 1/2”(2680)

EWCP4242-30 EWCP6642-30

24 3/32”(612)[2] 48 3/32”(1222)114”(2896)

114 3/4”(2915)120 1/2”(3061)117 1/2”(2985)

24 3/32”(612)[2] 60 3/32”(1526)126”(3200)

126 3/4”(3219)132 1/2”(3366)129 1/2”(3289)

EWCP5442-3042

”(10

67)

423/

4”(1

086)

467/

16”(

1180

)44

15/1

6”(1

141)

48”(

1219

)48

3/4”

(123

8)52

7/16

”(13

32)

5015

/16”

(129

4)

54”(

1372

)54

3/4”

(139

1)58

7/16

”(14

84)

5615

/16”

(144

6)

60”(

1524

)60

3/4”

(154

3)64

7/16

”(16

37)

6215

/16”

(159

9)

66”(

1676

)66

3/4”

(169

5)70

7/16

”(17

89)

6815

/16”

(175

1)

363/

32”(

917)

423/

32”(

1069

)48

3/32

”(12

22)

543/

32”(

1374

)60

3/32

”(15

26)

EWCP4248-30 EWCP6648-30EWCP5448-30

EWCP4254-30 EWCP6654-30EWCP5454-30

EWCP4260-30 EWCP6660-30EWCP5460-30

EWCP4266-30 EWCP6666-30EWCP5466-30

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGM.O. ADAMS/FLAT CASING

M.O. BRICKMOULD

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-37Architectural Detail ManualAugust 2010

Sector Top wood casements are constructed the same as Siteline EX wood casements(extruded cladding on wood sash).

Sector Top wood casement windows are available with left or right hand operation(hinged on the springline), or stationary (non-venting). Operating mechanisim includesstainless steel, corrosion resistant, butt hinges and single arm roto-type operator withhardened steel gears and operating arm. Sash locks are concealed unison type withexposed locking lever and escutcheon plate. There are several interior hardware finishoptions. Refer to Specifications for finish options.

WOOD SECTOR TOP CASEMENTS utilize some of the same options asWOOD CASEMENT.

GENERAL INFORMATIONSECTOR TOP CASEMENTS

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-38Architectural Detail ManualAugust 2010

CASEMENT UNIT HANDING:UNIT HANDING IS DEFINED(FROM THE EXTERIOR) AS THEDIRECTION THE SASH OPENS.

HANDLEFT

HANDRIGHT

UNIT HANDING INFORMATION

S OPERATING SINGLE SECTOR UNITS - MAY BE HANDED ’LEFT’ OR ’RIGHT’.

S OPERATING TWIN SECTOR UNITS - THESE UNITS ARE HINGED ON THE SPRINGLINE SIDE. THE ’LEFT’ SASH HAS ’LEFT’HAND OPERATION AND THE ’RIGHT’ SASH HAS ’RIGHT’ HAND OPERATION ONLY.

S OPERATING TRIPLE SECTOR UNITS - ONLY THE FLANKING UNITS MAY BE OPERATORS WHICH ARE HINGED ON THESPRINGLINE SIDE. THE TWO OPERATING SASH ARE HANDED THE SAME AS THE TWIN SECTOR.

OPERATOR OPERATOR

HANDING, OPERATION & LIMIT DEVICESECTOR TOP CASEMENTS

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-39Architectural Detail ManualAugust 2010

ELEVATION DRAWINGS UTILIZE A LIMITED NUMBER OF PROJECTED LINES TO PRODUCE A RUDIMENTARY DRAWINGINTENDED TO BE USED IN A SMALL GRAPHICAL SCALE. ELEVATIONS ARE VIEWED PERPENDICULAR FROM THEEXTERIOR OF THE STRUCTURE. IF MORE DIMENSIONS ARE NEEDED, USE THE SECTION DRAWINGS FOR MORECOMPLETE DEPICTIONS.

BOOK CODE

Masonry Openings for Brickmould, Flat & Adams Casing.Vertical measurements include subsill.(Subtract 1/2” from Masonry Opening for Unit Size)Glass Size

Frame Size

M.O. Brickmould

Rough OpeningM.O. Adams/Flat Casing

EWCS2442

1. UNIT ELEVATIONS ARE SHOWN WITH BRICKMOULD AND SUBSILL.

2. DIMENSIONAL VALUES IN BRACKETS ARE MILLIMETERCONVERSIONS.

3. ALL SECTOR UNITS ARE AVAILABLE AS OPERATING UNITS.

GENERAL SECTOR TOP CASEMENT NOTES

18 3/32”(460)24”(610)24 3/4”(629)30 1/2”(775)27 1/2”(699)

’EWCS’ INDICATESSITELINE EX CASEMENT SECTOR TOP

THE FIRST TWO NUMBERSINDICATE THE UNIT WIDTH

THE LAST TWO NUMBERS INDICATETHE UNIT HEIGHT

ELEVATION SYMBOL LEGEND:

M.O. MASONRY OPENING

36 3/32”(917)42”(1067)42 3/4”(1086)46 7/16”(1180)44 15/16”(1141)

ELEVATION NOTESSECTOR TOP CASEMENTS

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-40

SCALE 1/4” = 1’

Architectural Detail ManualAugust 2010

SECTOR TOP UNITS - 1-WIDE

Note: Elevations shown DO NOT have exterior trim. Subtract 1/2” (12.7) from M.O. (Masonry Opening) for Unit Sizes. Masonry Openings above include SillNose, see Trim Options page for Sill Nose specifications. For other Trim Options refer to the Unit Sizing, Rough Opening & Masonry Openings page.

363/

32”(

917)

42”(

1067

)42

3/4”

(108

6)46

7/16

”(11

80)

4415

/16”

(114

1)

423/

32”(

1069

)48

”(12

19)

483/

4”(1

238)

527/

16”(

1332

)50

15/1

6”(1

294)

483/

32”(

1222

)54

”(13

72)

543/

4”(1

391)

587/

16”(

1484

)56

15/1

6”(1

446)

18”(

457)

183/

4”(4

76)

227/

16”(

570)

2015

/16”

(532

)

24”(

610)

243/

4”(6

29)

287/

16”(

722)

2615

/16”

(684

)

30”(

762)

303/

4”(7

81)

347/

16”(

875)

3215

/16”

(837

)

36”(

914)

363/

4”(9

33)

407/

16”(

1027

)38

15/1

6”(9

89)

123/

32”(

307)

183/

32”(

460)

243/

32”(

612)

303/

32”(

764)

12 3/32”(307)18”(457)

18 3/4”(476)24 1/2”(622)21 1/2”(546)

14 3/32”(358)20”(508)

20 3/4”(527)26 1/2”(673)23 1/2”(597)

18 3/32”(460)24”(610)

24 3/4”(629)30 1/2”(775)27 1/2”(699)

22 3/32”(561)28”(711)

28 3/4”(730)34 1/2”(876)31 1/2”(800)

24 3/32”(612)30”(762)

30 3/4”(781)36 1/2”(927)33 1/2”(851)

30 3/32”(764)36”(914)

36 3/4”(933)42 1/2”(1080)39 1/2”(1033)

32”(813)32 3/4”(832)38 1/2”(978)35 1/2”(902)

26 3/32”(663)DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGM.O. ADAMS/FLAT CASING

M.O. BRICKMOULD

ELEVATION SYMBOL LEGEND:

VALUES IN () ARE IN MILLIMETER CONVERSIONSM.O. = MASONRY OPENING

EWCS1842 EWCS2042 EWCS2442 EWCS2842 EWCS3042 EWCS3642

EWCS1848 EWCS2048 EWCS2448 EWCS2848 EWCS3048 EWCS3648

EWCS1854 EWCS2054 EWCS2454 EWCS2854 EWCS3054 EWCS3654

EWCS1818 EWCS2018 EWCS2418 EWCS2818 EWCS3018 EWCS3618

EWCS1824 EWCS2024 EWCS2424 EWCS2824 EWCS3024 EWCS3624

EWCS1830 EWCS2030 EWCS2430 EWCS2830 EWCS3030 EWCS3630

EWCS1836 EWCS2036 EWCS2436 EWCS2836 EWCS3036 EWCS3636

EWCS3218

EWCS3224

EWCS3230

EWCS3236

EWCS3242

EWCS3248

EWCS3254

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50*

##** INDICATES OPTIONAL DESIGN PRESSURE (DP) RATING##* INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-41

SCALE 1/4” = 1’

Architectural Detail ManualAugust 2010

SECTOR TOP UNITS - 1-WIDE

Note: Elevations shown DO NOT have exterior trim. Subtract 1/2” (12.7) from M.O.(Masonry Opening) for Unit Sizes. Masonry Openings above include Sill Nose, seeTrim Options page for Sill Nose specifications. For other Trim Options refer to the UnitSizing, Rough Opening & Masonry Openings page.

543/

32”(

1374

)60

”(15

24)

603/

4”(1

543)

647/

16”(

1637

)62

15/1

6”(1

599)

603/

32”(

1526

)66

”(16

76)

663/

4”(1

695)

707/

16”(

1789

)68

15/1

6”(1

751)

EWCS1860 EWCS2060 EWCS2460 EWCS2860 EWCS3060 EWCS3660

EWCS1866 EWCS2066 EWCS2466 EWCS2866 EWCS3066 EWCS3666

663/

32”(

1679

)72

”(18

29)

723/

4”(1

848)

767/

16”(

1942

)74

15/1

6”(1

903)

EWCS1872 EWCS2072 EWCS2472 EWCS2872 EWCS3072 EWCS3672

12 3/32”(307)18”(457)

18 3/4”(476)24 1/2”(622)21 1/2”(546)

14 3/32”(358)20”(508)

20 3/4”(527)26 1/2”(673)23 1/2”(597)

18 3/32”(460)24”(610)

24 3/4”(629)30 1/2”(775)27 1/2”(699)

22 3/32”(561)28”(711)

28 3/4”(730)34 1/2”(876)31 1/2”(800)

24 3/32”(612)30”(762)

30 3/4”(781)36 1/2”(927)33 1/2”(851)

30 3/32”(764)36”(914)

36 3/4”(933)42 1/2”(1080)39 1/2”(1033)

84”(

2134

)84

3/4”

(215

3)88

7/16

”(22

46)

8615

/16”

(220

8)

783/

32”(

1984

)

EWCS1884 EWCS2084 EWCS2484

78”(

1981

)78

3/4”

(200

0)82

7/16

”(20

94)

8015

/16”

(205

6)

723/

32”(

1831

)

EWCS1878 EWCS2078 EWCS2478 EWCS2878 EWCS3078 EWCS3678EWCS3278

EWCS3272

EWCS3260

EWCS3266

32”(813)32 3/4”(832)38 1/2”(978)35 1/2”(902)

26 3/32”(663)DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGM.O. ADAMS/FLAT CASING

M.O. BRICKMOULD

ELEVATION SYMBOL LEGEND:

VALUES IN () ARE IN MILLIMETER CONVERSIONSM.O. = MASONRY OPENING

S AVAILABLE AS STATIONARY ONLY.

S S

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

35*50**

##** INDICATES OPTIONAL DESIGN PRESSURE (DP) RATING##* INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-42Architectural Detail ManualAugust 2010

SCALE 1/8” = 1’

SECTOR TOP UNITS - 2-WIDE

Note: Elevations shown DO NOT have exterior trim. Subtract 1/2” (12.7) from M.O. (Masonry Opening) for Unit Sizes. Masonry Openings above include SillNose, see Trim Options page for Sill Nose specifications. For other Trim Options refer to the Unit Sizing, Rough Opening & Masonry Openings page.

12 3/32”(307)[2]36”(914)

36 3/4”(933)42 1/2”(1080)39 1/2”(1003)

18”(

457)

183/

4”(4

76)

227/

16”(

570)

2015

/16”

(532

)

24”(

610)

243/

4”(6

29)

287/

16”(

722)

2615

/16”

(684

)

30”(

762)

303/

4”(7

81)

347/

16”(

875)

3215

/16”

(837

)

36”(

914)

363/

4”(9

33)

407/

16”(

1027

)38

15/1

6”(9

89)

42”(

1067

)42

3/4”

(108

6)46

7/16

”(11

80)

4415

/16”

(114

1)

48”(

1219

)48

3/4”

(123

8)52

7/16

”(13

32)

5015

/16”

(129

4)

54”(

1372

)54

3/4”

(139

1)58

7/16

”(14

84)

5615

/16”

(144

6)

60”(

1524

)60

3/4”

(154

3)64

7/16

”(16

37)

6215

/16”

(159

9)

66”(

1676

)66

3/4”

(169

5)70

7/16

”(17

89)

6815

/16”

(175

1)

72”(

1829

)72

3/4”

(184

8)76

7/16

”(19

42)

7415

/16”

(190

3)

40”(1016)40 3/4”(1035)46 1/2”(1181)43 1/2”(1105)

48”(1219)48 3/4”(1238)54 1/2”(1384)51 1/2”(1308)

56”(1422)56 3/4”(1441)62 1/2”(1588)59 1/2”(1511)

60”(1524)60 3/4”(1543)66 1/2”(1689)63 1/2”(1613)

72”(1829)72 3/4”(1848)78 1/2”(1994)75 1/2”(1918)

123/

32”(

307)

183/

32”(

460)

243/

32”(

612)

303/

32”(

764)

363/

32”(

917)

423/

32”(

1069

)48

3/32

”(12

22)

543/

32”(

1374

)60

3/32

”(15

26)

663/

32”(

1679

)14 3/32”(358)[2] 18 3/32”(460)[2] 22 3/32”(561)[2] 24 3/32”(612)[2] 30 3/32”(764)[2]

EWCS1818-2 EWCS2018-2 EWCS2418-2 EWCS2818-2 EWCS3018-2 EWCS3618-2

EWCS1824-2 EWCS2024-2 EWCS2424-2 EWCS2824-2 EWCS3024-2 EWCS3624-2

EWCS1830-2 EWCS2030-2 EWCS2430-2 EWCS2830-2 EWCS3030-2 EWCS3630-2

EWCS1836-2 EWC2036-2 EWCS2436-2 EWCS2836-2 EWCS3036-2 EWCS3636-2

EWCS1842-2 EWCS2042-2 EWCS2442-2 EWCS2842-2 EWCS3042-2 EWCS3642-2

EWCS1848-2 EWCS2048-2 EWCS2448-2 EWCS2848-2 EWCS3048-2 EWCS3648-2

EWCS1854-2 EWCS2054-2 EWCS2454-2 EWCS2854-2 EWCS3054-2 EWCS3654-2

EWCS1860-2 EWCS2060-2 EWCS2460-2 EWCS2860-2 EWCS3060-2 EWCS3660-2

EWCS1866-2 EWCS2066-2 EWCS2466-2 EWCS2866-2 EWCS3066-2 EWCS3666-2

EWCS1872-2 EWCS2072-2 EWCS2472-2 EWCS2872-2 EWCS3072-2 EWCS3672-2

EWCS3218-2

EWCS3224-2

EWCS3230-2

EWCS3236-2

EWCS3242-2

EWCS3248-2

EWCS3254-2

EWCS3260-2

EWCS3266-2

EWCS3272-2

64”(1626)64 3/4”(1645)70 1/2”(1791)67 1/2”(1715)

26 3/32”(663)[2]DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGM.O. ADAMS/FLAT CASING

M.O. BRICKMOULD

VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT

ELEVATION SYMBOL LEGEND:

VALUES IN () ARE IN MILLIMETER CONVERSIONSM.O. = MASONRY OPENING

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-43Architectural Detail ManualAugust 2010

SCALE 1/8” = 1’

SECTOR TOP UNITS - 2-WIDE

Note: Elevations shown DO NOT have exterior trim. Subtract 1/2” (12.7) from M.O. (Masonry Opening) for Unit Sizes. Masonry Openings above include SillNose, see Trim Options page for Sill Nose specifications. For other Trim Options refer to the Unit Sizing, Rough Opening & Masonry Openings page.

78”(

1981

)78

3/4”

(200

0)82

7/16

”(20

94)

8015

/16”

(205

6)

723/

32”(

1831

)

EWCS1878-2 EWCS2078-2 EWCS2478-2 EWCS2878-2 EWCS3078-2 EWCS3678-2EWCS3278-2

EWCS1884-2 EWCS2084-2 EWCS2484-2

84”(

2134

)84

3/4”

(215

3)88

7/16

”(22

46)

8615

/16”

(220

8)

783/

32”(

1984

)12 3/32”(307)[2]

36”(914)36 3/4”(933)

42 1/2”(1080)39 1/2”(1003)

40”(1016)40 3/4”(1035)46 1/2”(1181)43 1/2”(1105)

48”(1219)48 3/4”(1238)54 1/2”(1384)51 1/2”(1308)

56”(1422)56 3/4”(1441)62 1/2”(1588)59 1/2”(1511)

60”(1524)60 3/4”(1543)66 1/2”(1689)63 1/2”(1613)

72”(1829)72 3/4”(1848)78 1/2”(1994)75 1/2”(1918)

14 3/32”(358)[2] 18 3/32”(460)[2] 22 3/32”(561)[2] 24 3/32”(612)[2] 30 3/32”(764)[2]64”(1626)

64 3/4”(1645)70 1/2”(1791)67 1/2”(1715)

26 3/32”(663)[2]DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGM.O. ADAMS/FLAT CASING

M.O. BRICKMOULD

ELEVATION SYMBOL LEGEND:

VALUES IN () ARE IN MILLIMETER CONVERSIONSM.O. = MASONRY OPENING

S AVAILABLE AS STATIONARY ONLY.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT

S S

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-44Architectural Detail ManualAugust 2010

SCALE 1/8” = 1’

SECTOR TOP UNITS - 3-WIDE

Note: Elevations shown DO NOT have exterior trim. Subtract 1/2” (12.7) from M.O. (Masonry Opening) for Unit Sizes. Masonry Openings above include SillNose, see Trim Options page for Sill Nose specifications. For other Trim Options refer to the Unit Sizing, Rough Opening & Masonry Openings page.

VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT

ELEVATION SYMBOL LEGEND:

VALUES IN () ARE IN MILLIMETER CONVERSIONSM.O. = MASONRY OPENING

12 3/32”(307)[3]54”(1372)

54 3/4”(1391)60 1/2”(1537)57 1/2”(1461)

14 3/32”(358)[3] 18 3/32”(460)[3] 22 3/32”(561)[3]84”(2134)

84 3/4”(2153)90 1/2”(2299)87 1/2”(2223)

24 3/32”(612)[3]90”(2286)

90 3/4”(2305)96 1/2”(2451)93 1/2”(2375)

60”(1524)60 3/4”(1543)66 1/2”(1689)63 1/2”(1613)

72”(1829)72 3/4”(1848)78 1/2”(1994)75 1/2”(1918)

EWCS1818-3 EWCS2018-3 EWCS2418-3 EWCS2818-3 EWCS3018-318”(

457)

183/

4”(4

76)

227/

16”(

570)

2015

/16”

(532

)

24”(

610)

243/

4”(6

29)

287/

16”(

722)

2615

/16”

(684

)

30”(

762)

303/

4”(7

81)

347/

16”(

875)

3215

/16”

(837

)

36”(

914)

363/

4”(9

33)

407/

16”(

1027

)38

15/1

6”(9

89)

42”(

1067

)42

3/4”

(108

6)46

7/16

”(11

80)

4415

/16”

(114

1)

48”(

1219

)48

3/4”

(123

8)52

7/16

”(13

32)

5015

/16”

(129

4)

54”(

1372

)54

3/4”

(139

1)58

7/16

”(14

84)

5615

/16”

(144

6)

60”(

1524

)60

3/4”

(154

3)64

7/16

”(16

37)

6215

/16”

(159

9)

66”(

1676

)66

3/4”

(169

5)70

7/16

”(17

89)

6815

/16”

(175

1)

72”(

1829

)72

3/4”

(184

8)76

7/16

”(19

42)

7415

/16”

(190

3)

123/

32”(

307)

183/

32”(

460)

243/

32”(

612)

303/

32”(

764)

363/

32”(

917)

423/

32”(

1069

)48

3/32

”(12

22)

543/

32”(

1374

)60

3/32

”(15

26)

663/

32”(

1679

)

EWCS3218-3

26 3/32”(663)[3]96”(2438)

96 3/4”(2457)102 1/2”(2604)99 1/2”(2527)

EWCS1824-3 EWCS2024-3 EWCS2424-3 EWCS2824-3 EWCS3024-3 EWCS3224-3

EWCS1830-3 EWCS2030-3 EWCS2430-3 EWCS2830-3 EWCS3030-3 EWCS3230-3

EWCS1836-3 EWCS2036-3 EWCS2436-3 EWCS2836-3 EWCS3036-3 EWCS3236-3

EWCS1842-3 EWCS2042-3 EWCS2442-3 EWCS2842-3 EWCS3042-3 EWCS3242-3

EWCS1848-3 EWCS2048-3 EWCS2448-3 EWCS2848-3 EWCS3048-3 EWCS3248-3

EWCS1854-3 EWCS2054-3 EWCS2454-3 EWCS2854-3 EWCS3054-3 EWCS3254-3

EWCS1860-3 EWCS2060-3 EWCS2460-3 EWCS2860-3 EWCS3060-3 EWCS3260-3

EWCS1866-3 EWCS2066-3 EWCS2466-3 EWCS2866-3 EWCS3066-3 EWCS3266-3

EWCS1872-3 EWCS2072-3 EWCS2472-3 EWCS2872-3 EWCS3072-3 EWCS3272-3

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGM.O. ADAMS/FLAT CASING

M.O. BRICKMOULD

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-45Architectural Detail ManualAugust 2010

SCALE 1/8” = 1’

SECTOR TOP UNITS - 3-WIDE

Note: Elevations shown DO NOT have exterior trim. Subtract 1/2” (12.7) from M.O. (Masonry Opening) for Unit Sizes. Masonry Openings above include SillNose, see Trim Options page for Sill Nose specifications. For other Trim Options refer to the Unit Sizing, Rough Opening & Masonry Openings page.

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGM.O. ADAMS/FLAT CASING

M.O. BRICKMOULD

ELEVATION SYMBOL LEGEND:

VALUES IN () ARE IN MILLIMETER CONVERSIONSM.O. = MASONRY OPENING

VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT

78”(

1981

)78

3/4”

(200

0)82

7/16

”(20

94)

8015

/16”

(205

6)

723/

32”(

1831

)84

”(21

34)

843/

4”(2

153)

887/

16”(

2246

)86

15/1

6”(2

208)

783/

32”(

1984

)

EWCS1878-3 EWCS2078-3 EWCS2478-3 EWCS2878-3 EWCS3078-3 EWCS3278-3

EWCS1884-3 EWCS2084-3 EWCS2484-3

12 3/32”(307)[3]54”(1372)

54 3/4”(1391)60 1/2”(1537)57 1/2”(1461)

14 3/32”(358)[3] 18 3/32”(460)[3] 22 3/32”(561)[3]84”(2134)

84 3/4”(2153)90 1/2”(2299)87 1/2”(2223)

24 3/32”(612)[3]90”(2286)

90 3/4”(2305)96 1/2”(2451)93 1/2”(2375)

60”(1524)60 3/4”(1543)66 1/2”(1689)63 1/2”(1613)

72”(1829)72 3/4”(1848)78 1/2”(1994)75 1/2”(1918)

26 3/32”(663)[3]96”(2438)

96 3/4”(2457)102 1/2”(2604)99 1/2”(2527)

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-46Architectural Detail ManualAugust 2010

SCALE 1/8” = 1’

SECTOR TOP UNITS - 3-WIDE

Note: Elevations shown DO NOT have exterior trim. Subtract 1/2” (12.7) from M.O. (Masonry Opening) for Unit Sizes. Masonry Openings above include SillNose, see Trim Options page for Sill Nose specifications. For other Trim Options refer to the Unit Sizing, Rough Opening & Masonry Openings page.

DAYLIGHT OPENINGFRAME SIZE

ROUGH OPENINGM.O. ADAMS/FLAT CASING

M.O. BRICKMOULD

ELEVATION SYMBOL LEGEND:

VALUES IN () ARE IN MILLIMETER CONVERSIONSM.O. = MASONRY OPENING

S AVAILABLE AS STATIONARY ONLY.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT

S

30 3/32”(764)[3]108”(2743)

108 3/4”(2762)114 1/2”(2908)111 1/2”(2832)

EWCS3618-3

EWCS3624-3

EWCS3630-3

EWCS3636-3

EWCS3642-3

EWCS3648-3

EWCS3654-3

EWCS3660-3

EWCS3666-3

EWCS3672-3

EWCS3678-3

18”(

457)

183/

4”(4

76)

227/

16”(

570)

2015

/16”

(532

)

24”(

610)

243/

4”(6

29)

287/

16”(

722)

2615

/16”

(684

)

30”(

762)

303/

4”(7

81)

347/

16”(

875)

3215

/16”

(837

)

36”(

914)

363/

4”(9

33)

407/

16”(

1027

)38

15/1

6”(9

89)

42”(

1067

)42

3/4”

(108

6)46

7/16

”(11

80)

4415

/16”

(114

1)

48”(

1219

)48

3/4”

(123

8)52

7/16

”(13

32)

5015

/16”

(129

4)

54”(

1372

)54

3/4”

(139

1)58

7/16

”(14

84)

5615

/16”

(144

6)

60”(

1524

)60

3/4”

(154

3)64

7/16

”(16

37)

6215

/16”

(159

9)

66”(

1676

)66

3/4”

(169

5)70

7/16

”(17

89)

6815

/16”

(175

1)

72”(

1829

)72

3/4”

(184

8)76

7/16

”(19

42)

7415

/16”

(190

3)

123/

32”(

307)

183/

32”(

460)

243/

32”(

612)

303/

32”(

764)

363/

32”(

917)

423/

32”(

1069

)48

3/32

”(12

22)

543/

32”(

1374

)60

3/32

”(15

26)

663/

32”(

1679

)78

”(19

81)

783/

4”(2

000)

827/

16”(

2094

)80

15/1

6”(2

056)

723/

32”(

1831

)

30 3/32”(764)[3]108”(2743)

108 3/4”(2762)114 1/2”(2908)111 1/2”(2832)

S

Premium Wood

Siteline EX Primed Casement Windows

Architectural Detail ManualAugust 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-47

SASH GLAZING OPTIONSCASEMENT

SCALE 3” = 1’

INTERIOR GLAZING OPTIONS

5/DS//5/DS

1/4//1/4

7.3L//DS 3/16//3/16

DS//7.3L

PICTUREWINDOWS

ONLY

PICTUREWINDOWS

ONLY

PICTUREWINDOWS

ONLY

PICTUREWINDOWS

ONLY

7.0L//5/DS

CASEMENTPICTURE

5/DS//7.0L

CASEMENTPICTURE

CASEMENTPICTURE

15/16”

3/16”3/16”

13/16”

1/8” 1/8”

15/16”

1/4”1/4”

15/16”

1/8” 1/8”5/16”

13/16”

1/8” 1/8”1/4”

15/16”

1/8”5/16”1/8”

13/16”

1/8”1/4”1/8”

Premium Wood

Siteline EX Primed Casement Windows

JELD-WEN reserves the right to change specifications without notice. Page 2-48Architectural Detail ManualNovember 2013

DIRECT-SET GLAZING OPTIONS

Note: Dual pane and tripane Insulated Glass shown with stainless steelwarmedge spacer may also be built with aluminum box spacer depending onshape, glass type, or special grille bar pattern.

Note: Glazing options shown are available in Clad Geometric Direct-SetWindows with frame as shown and also in Clad Radius Direct-GlazedWindows and Wood Geometric and Radius Direct-Glazed Windows. Seepages 9-74 to 9-77 for Clad Radius window frame and pages 11-73 to 11-76for Wood Geometric and Radius frame details.

STANDARD INSULATEDGLASS

STANDARD INSULATEDGLASS

STANDARD INSULATEDGLASS

STANDARD INSULATEDGLASS

STANDARD INSULATEDGLASS

LAMINATED INSULATEDCLEAR OR LOW E GLASS

LAMINATED INSULATEDTINTED GLASS

LAMINATED INSULATEDSINGLE GLASS

DS TRIPANE INSULATEDGLASS

5/32” TRIPANE INSULATEDGLASS

3/16” TRIPANE INSULATEDGLASS

1 7/16”

1/2” 7/16”1/8”1/8”

1 5/16”1/2” 7/16”

1/8”1/8”

7/8”

1/8”

1/4”

1/8”1/8”

7/8”

1/8”

1/4”1/8”1/8”

1/8”

15/16”

1/4” 1/4”

7/8”

3/16”3/16”

13/16”

1/8”1/8”3/4”1/8”1/8”

11/16”

1/16”1/16”

1 1/2”

1/2” 7/16”3/16” 3/16”

GLAZING OPTIONSDIRECT-SET

Premium Wood

Siteline EX Primed Casement Windows

Architectural Detail ManualAugust 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-49

WOOD SUBSILL OPTIONS

WOOD EXTERIOR TRIM

BRICKMOULD FLAT CASING ADAMS CASING

2” [51]

1 3/32” [28]

1 1/2” [38]

3 1/2” [89]

1 1/16” [27]

3” [76]3 1/2” [89]

1 1/16” [27]

3” [76]

1 5/16” [33]

1 X 4 BACK BAND WILLIAMSBURG RG 3 CASING

3 31/32” [101]2 3/4” [70] 2 31/32” [75]

1 1/16” [27]1 3/16” [30]

1 7/32” [31]

3 15/32” [88]3 1/4” [83]

4 1/2” [114]

1 7/16” [36]

1 5/16” [33]

STANDARD

1 1/8” [29]

15/16” [24]

2 1/32” [51]

1 5/16” [33]

1 1/2” [38]

OPTIONAL 2” SILL(ALUMINUM)

TRIM OPTIONSCASEMENT

SCALE: 3” = 1’

Premium Wood

Siteline EX Primed Casement Windows

Architectural Detail ManualAugust 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-50

WOOD SUBSILL OPTIONS

WOOD EXTERIOR TRIM

BRICKMOULD FLAT CASING ADAMS CASING

2” [51]

1 3/32” [28]

1 1/2” [38]

3 1/2” [89]3” [76]

3 1/2” [89]3” [76]

OPTIONAL

1 5/16” [33]

1 7/16” [36]

1 5/16” [33]

STANDARD

1 1/8” [29]

15/16” [24]

2 1/32” [51]

1 5/16” [33]

2” SILL

1 1/2” [38]

1 3/32” [28] 1 3/32” [28]

(ALUMINUM)

TRIM OPTIONSSECTOR TOP

SCALE: 3” = 1’

Premium Wood

Siteline EX Primed Casement Windows

Architectural Detail ManualAugust 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-51

JAMB EXTENDER & STUCCO TRIM OPTIONS

Notes:

Jamb Extension (9/16” thick) only available on jambs up to 6-9/16”.Jambs over 6-9/16” will only have a 4/4 or 5/4 option.Jambs over 8-1/2” up 12” will be 2 layers.Kerfed Jamb Extension only available on 4/4 or 5/4 options.

1 5/32” [29]

9/16” [14]

4 9/16” [116]

7 13/16” [198]

1 5/32” [29]

9/16” [14]

4 1/16” [103]

7 13/16” [198]

1 5/32” [29]

4 1/16” [103]

12” [305] 7 13/16” [198] 9 7/8” [251]

4 3/4” [121]

3 1/2” [89]

1 5/32” [29]21/32” [17]

4 1/16” [103]

1 1/8” [29]

1 5/32” [29]

1 1/8” [29]

21/32” [17]

1/4” [6]

5/16” [8]

2 1/16” [52]

4 1/16” [103]

21/32” [17]

7 13/16” WALL

12” WALL 7 13/16” WALL 9 7/8” WALL5/4 JAMB THICKNESS (OPTION) 5/4-4/4 STACKED KERFED

4 9/16” WALL 7 13/16” WALL4/4 JAMB THICKNESS (STANDARD)9/16” JAMB THICKNESS (OPTION)

4/4 JAMB THICKNESS (STANDARD)2 PC JAMB EXTENSION SHOWN JAMB OPTION

SCALE: 3” = 1’

Premium Wood

Siteline EX Primed Casement Windows

Architectural Detail ManualAugust 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-52

STANDARD MULLION OPTIONS

TWIN OPERATING CASEMENT OPERATING CASEMENT WITHFIXED UNIT

OPERATING CASEMENT WITHFIXED TRANSOM

DIRECT-SET OVER CASEMENT

RADIUS OVER CASEMENT

DIRECT-SET NEXT TO CASEMENT

1 5/32” [29]

5 29/32” [150]3 5/8” [92]2 5/16” [59]

5 29/32” [150]3 5/8” [92]

2 5/16” [59]

1 5/32” [29]

4 13/16” [122]

3 21/32” [93]

2 5/16” [59]1 5/32” [29]

5 29/32” [150]

3 5/8” [92]

2 5/16” [59]1 5/32” [29]

4 13/16” [122]3 21/32” [93]

2 5/16” [59]

1 5/32” [29]

1 5/32” [29]

4 13/16” [122]

4 13/16” [122]

2 5/16” [59]

Premium Wood

Siteline EX Primed Casement Windows

Architectural Detail ManualAugust 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-53

LITE CUT INFORMATION

DIAMOND GOTHICRADIUS

RECTANGULAR HORIZONTAL UNEVENPRAIRIE

LITE CUT OPTIONS

Special lite cut patterns can include a

wide variety of straight line and radius

patterns. The illustrations shown here

represent just a few of the possibilities.

Rectangular, horizontal, vertical and

Prairie lite patterns are available in all

standard size wood casement windows.

Uneven, diamond, radius and Gothic lite

cuts are available, subject to approval.

Approvals are based on the ability to

fulfill the design requirement while

maintaining the construction integrity of

the finished product.

BAR ALIGNMENT

Alignment of divided lite muntin bars from one window

to the next is often required by fine architectural

design. Wood grilles, GBG (Grilles between the Glass),

and Simulated Divided Lites may be specified with muntin

bars aligned.

Wood casement windows are available in 7/8”, 1-1/8” and 1-3/8” widths for SDL (Simulated Divided Lites);5/8” Flat, 23/32” and 1” Contour GBG (Grilles between the Glass); and 7/8”, 1-1/8” and 1-3/8” Full Surroundremovable grilles. Standard lite cuts are rectangular.

Premium Wood

Siteline EX Primed Casement Windows

Architectural Detail ManualNovember 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-54

DIVIDED LITE OPTIONSCASEMENT

GRILLES MEETING

GRILLE PROFILES:3/16” x 5/8” ALLMETAL 1021101018XX1403/16” x 1” ALLMETAL 1020101018XX1641/4” x 5/8” ALLMETAL 1020102018XX1401/4” x 1” ALLMETAL 1020102018XX1645.5mm x 18mm CONTOUR ALLMETAL 1020301010XX2558mm x 25mm CONTOUR ALLMETAL 1020301018XX380

NFRC 3mm RULE

7/8” SDL 1 1/8” SDL 1 3/8” SDL 2 5/16” SDL

5/8” GRILLE 23/32” GRILLE 1” GRILLE 5/8” GRILLE

1/4”

3/16”

5/8”

3/4”

3/16”

11/16”

3/4”3/4”

5/16”

1”

11/16”

3/16”

5/8”

3/4”

1/4”

3/4”

1/4”

3/4”3/4”

1/4”

7/8”

5/16” 5/16”

7/8”

5/16” 5/16”

2 5/16” 2 5/16”

5/16” 5/16”

1 3/8” 1 3/8”

5/16”

1 1/8”

5/16”

1 1/8”

5/8” PUTTY/PUTTY SDL

1/4”

3/4”

5/8” 5/8”

3/8”

7/8” PUTTY/PUTTY SDL

1/4”

3/4”

7/8” 7/8”

3/8”

1 1/8” PUTTY/PUTTY SDL

1/4”

3/4”

1 1/8” 1 1/8”

3/8”

5/8” PUTTY/BEAD SDL

1/4”

3/4”

5/8” 5/8”

3/8”

7/8” PUTTY/BEAD SDL

1/4”

3/4”

7/8” 7/8”

3/8”

1 1/8” PUTTY/BEAD SDL

1/4”

3/4”

1 1/8” 1 1/8”

3/8”

3/8” 3/8” 3/8”

3/8” 3/8” 3/8”

Premium Wood

Siteline EX Primed Casement Windows

SCALE: NTS

Architectural Detail ManualNovember 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-55

DIVIDED LITE OPTIONSDIRECT SET

GRILLES MEETINGNFRC 3mm RULE

GRILLE PROFILES

3/16” X 5/8” ALLMETAL 1021101018XX1401/4” X 5/8” ALLMETAL 1020102018XX1401/4” X 1” ALLMETAL 1020102018XX164.325” X 5/8” ALLMETAL 1020106018XX140.325” x 1” ALLMETAL 1020103018XX1645.5mm X 18mm Contour ALLMETAL 1020301010XX2558mm X 25mm Contour ALLMETAL 1020301018XX380

5/8” GRILLE 23/32” GRILLE 1” GRILLE

13/16”

3/16”

13/16”

3/16”

13/16”

5/16”

1”11/16”5/8”

7/8” SDL 1 1/8” SDL 1 3/8” SDL 2 5/16” SDL

1/4”

3/4”

1/4”

3/4”

1/4”

3/4”3/4”

1/4”

7/8”

5/16” 5/16”

7/8”

5/16” 5/16”

2 5/16” 2 5/16”

5/16” 5/16”

1 3/8” 1 3/8”

5/16”

1 1/8”

5/16”

1 1/8”

5/8” PUTTY/PUTTY SDL

1/4”

3/4”

5/8” 5/8”

3/8”

7/8” PUTTY/PUTTY SDL

1/4”

3/4”

7/8” 7/8”

3/8”

1 1/8” PUTTY/PUTTY SDL

1/4”

3/4”

1 1/8” 1 1/8”

3/8”

5/8” PUTTY/BEAD SDL

1/4”

3/4”

5/8” 5/8”

3/8”

7/8” PUTTY/BEAD SDL

1/4”

3/4”

7/8” 7/8”

3/8”

1 1/8” PUTTY/BEAD SDL

1/4”

3/4”

1 1/8” 1 1/8”

3/8”

3/8” 3/8” 3/8”

3/8” 3/8” 3/8”

Premium Wood

Siteline EX Primed Casement Windows

SCALE: NTS

Architectural Detail ManualAugust 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-56

NON-STANDARD UNIT SIZING

EXTERIOR TRIM OFFERINGS WITH SUBSILL

EXTERIOR TRIM ON ALL 4 SIDESEXTERIOR TRIM OFFERINGS WITHOUT SUBSILL

VER

TIC

AL

VER

TIC

AL

WIT

HSU

BSIL

LRO

UG

HO

PEN

ING

WIT

HO

UT

SUBS

ILL

ROU

GH

OPE

NIN

GFRAME TO TRIM

1” [25]

DIMENSIONS

TYPICAL FOR HEAD, SILL & SIDEABOVE ARE THE SAME

TRIM OFFERINGSHORIZONTAL SECTION

WITH OR WITHOUT SUBSILL

SUBS

ILL

ON

LYU

NIT

SIZE

UN

ITSI

ZE2”

BRIC

KM

OU

LD

3/8” [10]

ROUGH OPENING IS ALWAYS 1/2” OVER

MASONRY OPENING IS ALWAYS 1/2” OVERO

PERA

TOR

OPERATOR

FIX

ED

3/8” [10]

EXCEPTION: SEE DRAWING BELOW

3/4” [19]

WITH OR WITHOUT TRIM

ROUGH OPENING:

MASONRY OPENING:

UNIT SIZE IS ALWAYS THE

FRAME SIZE OF THE WINDOW

THE UNIT SIZE OF THE WINDOW

EXTREME SIZE OF THE WINDOW

HORIZONTALROUGH OPENING

OF BRICKMOULD & SUBSILL

STANDARD OFFERING

FIXED

UNIT SIZE = FRAME SIZE

GENERAL NOTES:UNITS WITH NO TRIM AND SUBSILL:

BRICKMOULDUNIT SIZE

FRA

ME

+2

7/16

”[6

2]BR

ICK

MO

ULD

&SU

BSIL

LU

NIT

SIZE

FRAME + 3” [76]FR

AM

E+

15/1

6”[2

4]

FRA

ME

+2

7/16

”[6

2]

UN

ITSI

ZE1

X4

BAC

KBA

ND

FRA

ME

+4

15/1

6”[1

25]

NO

TRIM

UN

ITSI

ZE

UN

ITSI

ZE2”

BRIC

KM

OU

LD

FRA

ME

=U

NIT

SIZE

FRA

ME

+3”

[76]

UN

ITSI

ZE3

1/2”

FLA

TC

ASI

NG

&A

DA

MS

CA

SIN

GFR

AM

E+

6”[1

52]

UN

ITSI

ZE3

1/2”

FLA

TC

ASI

NG

&A

DA

MS

CA

SIN

GFR

AM

E+

315

/16”

[100

]

UN

ITSI

ZEW

ILLI

AM

SBU

RGFR

AM

E+

311

/16”

[94]

UN

ITSI

ZERB

3C

ASI

NG

FRA

ME

+3

29/3

2”[9

9]

UN

ITSI

ZE1

X4

BAC

KBA

ND

FRA

ME

+8”

[203

]

UN

ITSI

ZEW

ILLI

AM

SBU

RGFR

AM

E+

51/

2”[1

40]

UN

ITSI

ZERB

3C

ASI

NG

FRA

ME

+5

15/1

6”[1

51]

NO TRIMUNIT SIZE

UNIT SIZE2” BRICKMOULD

FRAME = UNIT SIZE

FRAME + 3” [76]

UNIT SIZE3 1/2” FLAT CASING& ADAMS CASINGFRAME + 6” [152]

UNIT SIZE1 X 4 BACK BANDFRAME + 8” [203]

UNIT SIZEWILLIAMSBURG

FRAME + 5 1/2” [140]

UNIT SIZERB 3 CASING

FRAME + 5 15/16” [151]

1 1/2” [38]STANDARDBRICKMOULD

2 3/4” [70]WILLIAMSBURG

2 31/32” [75]RB 3 CASING

3” [76]3 1/2” FLAT &ADAMS CASING

4” [102]1 X 4 BACK BAND

UNIT SIZING, ROUGH OPENINGS& MASONRY OPENINGS

Premium Wood

Siteline EX Primed Casement Windows

Architectural Detail ManualAugust 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-57

1-WIDE UNIT

VERTICAL SECTION

Uni

tSi

ze

Sash

Size

Gla

ssSi

ze

Day

light

Ope

ning

Scre

enSi

ze

Fram

eSi

ze

Roug

hO

peni

ng

5 5/8”

1 1/8”

4 9/16”

13/16”

3 3/4”

7/16”

1 9/16”

2 7/16”

7/16”

1 9/16”

1 7/8”

5 7/8”

1 5/16”

4 9/16”

3 3/4”13/16”

3/4”

2 9/16”

1 5/8”

Premium Wood

Siteline EX Primed Casement Windows

SCALE: 6” = 1’

Architectural Detail ManualAugust 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-58

1-WIDE UNIT

HORIZONTAL SECTION

1/8”

3/4”

Unit Size

Sash Size

Glass Size

Daylight Opening

Screen Size

Frame Size

Rough Opening

5 11/16”

1 1/8”

4 9/16”

3 3/4”

13/16”

2 7/16”

1 9/16”

7/16” 7/16”

1 9/16”

2 7/16”

1 5/8” 1 5/8”

5 11/16”

1 1/8”

4 9/16”

3 3/4”

13/16”

3/8” 3/8”

Premium Wood

Siteline EX Primed Casement Windows

SCALE: 6” = 1’

Architectural Detail ManualAugust 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-59

COMBINATION UNIT

HO

RIZ

ON

TAL

SEC

TIO

N

1/8”

3/4”

511

/16” 1

1/8”

49/

16”

33/

4”

13/1

6”

1/8”

Sash

Size

Gla

ssSi

ze

Day

light

Ope

ning

19/

16”

7/16

”7/

16”

19/

16”

19/

16”

7/16

Scre

enSi

ze1

5/8”

3/8”

27/

16”

Gla

ssSi

ze

Sash

Size

Day

light

Ope

ning

Scre

enSi

ze

Roug

hO

peni

ng

Fram

eSi

ze

Uni

tSi

ze

Premium Wood

Siteline EX Primed Casement Windows

SCALE: 6” = 1’

Architectural Detail ManualAugust 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-60

PICTURE UNIT

VERTICAL SECTION

5 7/8”

1 5/16” 4 9/16”

13/16”

1 9/16”2 3/16”

5 11/16”

1 1/8” 4 9/16”

13/16”

3 3/4”

Fram

eSi

ze

Roug

hO

peni

ng

3/4”

Uni

tSi

ze

Sash

Size

Gla

ssSi

ze

Day

light

Ope

ning

1 7/8”

1 9/16”

7/16”

2 7/16”

1 9/16”

7/16”

Premium Wood

Siteline EX Primed Casement Windows

SCALE: 6” = 1’

Architectural Detail ManualAugust 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-61

PICTURE UNIT

HORIZONTAL SECTION

3/4”

1/8”

Unit Size

Sash Size

Glass Size

Daylight Opening

Frame Size

Rough Opening

3/8” 3/8”

5 11/16”

1 1/8”

4 9/16”

13/16”

3 3/4”5 11/16”

1 1/8”

4 9/16”

13/16”

3 3/4”

2 7/16”

1 9/16”

7/16” 7/16”

1 9/16”

2 7/16”

Premium Wood

Siteline EX Primed Casement Windows

SCALE: 6” = 1’

Architectural Detail ManualAugust 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-62

PICTURE UNIT WITH FLANKER

HO

RIZ

ON

TAL

SEC

TIO

N

1/8”

3/4”

511

/16” 11/

8”

49/

16”

33/

4”

13/1

6”

1/8”

Sash

Size

Gla

ssSi

ze

Day

light

Ope

ning

19/

16”

7/16

”7/

16”

19/

16”

19/

16”

7/16

Scre

enSi

ze1

5/8”

3/8”

Uni

tSi

ze

Day

light

Ope

ning

Gla

ssSi

ze

Sash

Size

Roug

hO

peni

ng

Fram

eSi

ze

Premium Wood

Siteline EX Primed Casement Windows

SCALE: 6” = 1’

Architectural Detail ManualAugust 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-63

SECTOR TOP UNIT

VERTICAL SECTION

Uni

tSi

ze

Sash

Size

Gla

ssSi

ze

Day

light

Ope

ning

Fram

eSi

ze

Roug

hO

peni

ng

3/4”

5 5/8”

1 1/8”

4 9/16”

13/16”

3 3/4”

5 7/8”

1 5/16”

4 9/16”

3 3/4”13/16”

7/16”

1 9/16”

1 7/8”

7/16”

1 9/16”

2 7/16”

Premium Wood

Siteline EX Primed Casement Windows

SCALE: 6” = 1’

Architectural Detail ManualAugust 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-64

SECTOR TOP UNIT - 1-WIDE

HORIZONTAL SECTION

1/8”

3/4”

Unit Size

Sash Size

Glass Size

Daylight Opening

2 7/16”

1 9/16”

7/16” 7/16”

1 9/16”

2 7/16”

5 11/16”

1 1/8”

4 9/16”

3 3/4”

13/16”

5 11/16”

1 1/8”

4 9/16”

3 3/4”

13/16”

Frame Size

Rough Opening

3/8” 3/8”

Premium Wood

Siteline EX Primed Casement Windows

SCALE: 6” = 1’

Architectural Detail ManualAugust 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-65

SECTOR TOP UNIT - 2-WIDE

HO

RIZ

ON

TAL

SEC

TIO

N

1/8”

3/4”

511

/16” 1

1/8”

49/

16”

33/

4”

13/1

6”

1/8”

Sash

Size

Gla

ssSi

ze

Day

light

Ope

ning

19/

16”

7/16

”7/

16”

19/

16”

19/

16”

7/16

Scre

enSi

ze1

5/8”

3/8”

27/

16”

Gla

ssSi

ze

Sash

Size

Day

light

Ope

ning

Scre

enSi

ze

Roug

hO

peni

ng

Fram

eSi

ze

Uni

tSi

ze

Premium Wood

Siteline EX Primed Casement Windows

SCALE: 6” = 1’

Architectural Detail ManualAugust 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-66

BAY WINDOW HORIZONTAL SPECIFICATION TABLES

A (Rough Opening)

G + 1-51/64”

D + 11/16”

G + 1-51/64”

F (Unit Width)

D

G

BE

C

45° Bay RO Interface

A (Rough Opening)

D

G

BE

F (Unit Width)

G+1-55/64”

D+29/32”

G+1-55/64”

C

30° Bay RO Interface

30_ BAY 45_ BAYA F B C E D G A F B C E D G

FlankerWidth

CenterWidth

RoughOpening

UnitWidth

OverallProjection

ProjectionExterior

WallSeatingDepth

OutsideMull to

Mull

OutsideMull to

UnitFlankerWidth

CenterWidth

RoughOpening

UnitWidth

OverallProjection

ProjectionExterior

WallSeatingDepth

OutsideMull to

Mull

OutsideMull to

Unit

18 18 52 13/16 56 5/8 14 13/16 10 1/4 18 9/16 20 19 18 18 47 3/8 52 7/16 19 7/16 14 7/8 15 11/16 21 1/8 19 9/16

18 36 70 13/16 74 5/8 14 13/16 10 1/4 18 9/16 38 19 18 36 65 3/8 70 7/16 19 7/16 14 7/8 15 11/16 39 1/8 19 9/16

18 42 76 13/16 80 5/8 14 13/16 10 1/4 18 9/16 44 19 18 42 71 3/8 76 7/16 19 7/16 14 7/8 15 11/16 45 1/8 19 9/16

18 54 88 13/16 92 5/8 14 13/16 10 1/4 18 9/16 56 19 18 54 83 3/8 88 7/16 19 7/16 14 7/8 15 11/16 57 1/8 19 9/16

18 66 100 13/16 104 5/8 14 13/16 10 1/4 18 9/16 68 19 18 66 95 3/8 100 7/16 19 7/16 14 7/8 15 11/16 69 1/8 19 9/16

20 20 58 5/16 62 1/16 15 13/16 11 1/4 19 9/16 22 21 20 20 52 1/4 57 1/4 20 7/8 16 5/16 17 1/8 23 1/8 21 9/16

20 40 78 5/16 82 1/16 15 13/16 11 1/4 19 9/16 42 21 20 40 72 1/4 77 1/4 20 7/8 16 5/16 17 1/8 43 1/8 21 9/16

20 42 80 5/16 84 1/16 15 13/16 11 1/4 19 9/16 44 21 20 42 74 1/4 79 1/4 20 7/8 16 5/16 17 1/8 45 1/8 21 9/16

20 54 92 5/16 96 1/16 15 13/16 11 1/4 19 9/16 56 21 20 54 86 1/4 91 1/4 20 7/8 16 5/16 17 1/8 57 1/8 21 9/16

20 60 98 5/16 102 1/16 15 13/16 11 1/4 19 9/16 62 21 20 60 92 1/4 97 1/4 20 7/8 16 5/16 17 1/8 63 1/8 21 9/16

20 66 104 5/16 108 1/16 15 13/16 11 1/4 19 9/16 68 21 20 66 98 1/4 103 1/4 20 7/8 16 5/16 17 1/8 69 1/8 21 9/16

24 24 69 3/16 73 17 13/16 13 1/4 21 9/16 26 25 24 24 61 7/8 66 7/8 23 11/16 19 1/8 19 15/16 27 1/8 25 9/16

24 42 87 3/16 91 17 13/16 13 1/4 21 9/16 44 25 24 42 79 7/8 84 7/8 23 11/16 19 1/8 19 15/16 45 1/8 25 9/16

24 48 93 3/16 97 17 13/16 13 1/4 21 9/16 50 25 24 48 85 7/8 90 7/8 23 11/16 19 1/8 19 15/16 51 1/8 25 9/16

24 54 99 3/16 103 17 13/16 13 1/4 21 9/16 56 25 24 54 91 7/8 96 7/8 23 11/16 19 1/8 19 15/16 57 1/8 25 9/16

24 66 111 3/16 115 17 13/16 13 1/4 21 9/16 68 25 24 66 103 7/8 108 7/8 23 11/16 19 1/8 19 15/16 69 1/8 25 9/16

24 72 117 3/16 121 17 13/16 13 1/4 21 9/16 74 25 24 72 109 7/8 114 7/8 23 11/16 19 1/8 19 15/16 75 1/8 25 9/16

30 30 85 5/8 89 3/8 20 13/16 16 1/4 24 9/16 32 31 30 30 76 3/8 81 3/8 27 15/16 23 3/8 24 3/16 33 1/8 31 9/16

30 42 97 5/8 90 3/8 20 13/16 16 1/4 24 9/16 44 31 30 42 88 3/8 93 3/8 27 15/16 23 3/8 24 3/16 45 1/8 31 9/16

30 54 109 5/8 91 3/8 20 13/16 16 1/4 24 9/16 56 31 30 54 100 3/8 105 3/8 27 15/16 23 3/8 24 3/16 57 1/8 31 9/16

30 60 115 5/8 92 3/8 20 13/16 16 1/4 24 9/16 62 31 30 60 106 3/8 111 3/8 27 15/16 23 3/8 24 3/16 63 1/8 31 9/16

30 66 121 5/8 93 3/8 20 13/16 16 1/4 24 9/16 68 31 30 66 112 3/8 117 3/8 27 15/16 23 3/8 24 3/16 69 1/8 31 9/16

30 90 145 5/8 94 3/8 20 13/16 16 1/4 24 9/16 92 31 30 90 136 3/8 141 3/8 27 15/16 23 3/8 24 3/16 93 1/8 31 9/16

Measurements are to the nearest 1/16”.

Premium Wood

Siteline EX Primed Casement Windows

Architectural Detail ManualAugust 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-67

* Measurements to the nearest 1/16”.

Continued on next page

D+3/16” G+1-19/32”

A (Rough Opening)

F (Unit Width)D

BE

G+1-19/32”

G

C

D+3/16”

G+1-19/32”

D+3/16”

G+1-19/32”

A (Rough Opening)

BE

F (Unit Width)

D

GC

BOW WINDOW HORIZONTAL SPECIFICATION TABLES

3 Wide Wood Bow*

A F B C E D G

Frame Width Rough OpeningOverall

Unit WidthOverall

ProjectionProjection

Exterior Wall Seating DepthOutside Mull

to MullOutside Mull

to Unit

18 55 7/16 58 1/8 8 3 7/16 4 1/4 18 5/8 18 5/16

20 61 3/8 63 11/16 8 3/8 3 13/16 4 5/8 20 5/8 20 5/16

24 73 1/4 75 9/16 9 1/16 4 1/2 5 5/16 24 5/8 24 5/16

28 85 1/8 87 7/16 9 3/4 5 3/16 6 28 5/8 28 5/16

30 91 1/16 93 3/8 10 1/8 5 9/16 6 3/8 30 5/8 30 5/16

4 Wide Wood Bow*

A F B C E D G

Frame Width Rough OpeningOverall

Unit WidthOverall

ProjectionProjection

Exterior Wall Seating DepthOutside Mull

to MullOutside Mull

to Unit

18 73 1/8 76 1/16 11 5/16 6 3/4 7 9/16 18 5/8 18 5/16

20 80 15/16 83 7/8 12 7 7/16 8 1/4 20 5/8 20 5/16

24 96 11/16 99 5/8 13 3/8 8 13/16 9 5/8 24 5/8 24 5/16

28 112 3/8 115 5/16 14 3/4 10 3/16 11 28 5/8 28 5/16

30 120 3/16 123 1/8 15 1/2 10 7/8 11 11/16 30 5/8 30 5/16

Premium Wood

Siteline EX Primed Casement Windows

Architectural Detail ManualAugust 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-68

* Measurements to the nearest 1/16”.

D+3/16”D+3/16”

G+1-19/32”

D+3/16”

G+1-19/32”

F (Unit Width)D

BE

G

D

C

A (Rough Opening)

D+3/16”

D+3/16”

G+1-19/32”

D+3/16”

D+3/16”

G+1-19/32”

D

D

G

F (Unit Width)

BE

A (Rough Opening)

C

BOW WINDOW HORIZONTAL SPECIFICATION TABLES

5 Wide Wood Bow*

A F B C E D G

Frame Width Rough OpeningOverall

Unit WidthOverall

ProjectionProjection

Exterior Wall Seating DepthOutside Mull

to MullOutside Mull

to Unit

18 90 1/4 93 7/16 14 9/16 10 10 13/16 18 5/8 18 5/16

20 99 15/16 103 1/8 15 5/8 11 1/16 11 7/8 20 5/8 20 5/16

24 119 5/16 122 1/2 17 11/16 13 1/8 13 15/16 24 5/8 24 5/16

28 138 3/4 141 15/16 19 3/4 15 3/16 16 28 5/8 28 5/16

30 148 7/16 151 5/8 20 3/4 16 3/16 17 30 5/8 30 5/16

6 Wide Wood Bow*

A F B C E D G

Frame Width Rough OpeningOverall

Unit WidthOverall

ProjectionProjection

Exterior Wall Seating DepthOutside Mull

to MullOutside Mull

to Unit

18 106 5/8 110 1/16 19 3/8 14 13/16 15 5/8 18 5/8 18 5/16

20 118 1/16 121 1/2 20 15/16 16 3/8 17 1/8 20 5/8 20 5/16

24 141 144 7/16 24 19 7/16 20 1/4 24 5/8 24 5/16

28 163 15/16 167 3/8 27 1/16 22 1/2 23 5/16 28 5/8 28 5/16

30 175 7/16 178 7/8 28 5/8 24 1/16 24 13/16 30 5/8 30 5/16

Premium Wood

Siteline EX Primed Casement Windows

Architectural Detail ManualAugust 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-69

BAY & BOW WINDOW ROUGH OPENINGS

Continued on next page

Rough Opening

Rough Opening

3/4” [19]1 1/2” [38]

BASI

CU

NIT

FRA

ME

HEI

GH

T

OV

ERA

LLFR

AM

EH

EIG

HT

+1-

1/2”

OV

ERA

LLRO

UG

HO

PEN

ING

+3/

4”

OV

ERA

LLU

NIT

HEI

GH

T(B

ASI

CU

NIT

FRA

ME

HEI

GH

T+

17/

8”[4

8]

7/8” [22] 3/4” [19]

SEATBOARD

OV

ERA

LLFR

AM

EH

EIG

HT

+1-

1/2”

OV

ERA

LLRO

UG

HO

PEN

ING

+3/

4”

OV

ERA

LLU

NIT

HEI

GH

T(B

ASI

CU

NIT

FRA

ME

HEI

GH

T+

25/

8”[6

7]

3/4” [19]

Vertical Masonry Opening will be 1/2” [13]larger than the Overall Unit Size.

3/4” [19]

HEADBOARD

Vertical Masonry Opening will be 1/2” [13]larger than the Overall Unit Size.

3/8” [10]

Exterior of Wall

Rough Opening ismeasured from thepoint the frame intersectsthe jamb aligner.

Exterior of Wall

3/8” [10]

Rough Opening ismeasured from thepoint the frame intersectsthe jamb aligner.

1 5/16” [33]

1 5/16” [33]

SEATBOARD

HEADBOARD

with Brickmould

4, 5 & 6 WIDE BOWS

Rough Opening typical for all Units

45° Bay Shown

30° & 45° BAYS

HORIZONTAL ROUGH OPENING

without trim4 Wide Bow Shown

BAY & BOW WINDOW TRIM OPTIONSThe standard offering for wood bay & bow windows is ’frame only’, brickmould and subsill, subsill only, and brickmould on all sides.

Other trim options subject to approval. Rough & Masonry openings remain consistent with all trim options.

SUBSILL ONLY

BRICKMOULD & SUBSILL

Rough Opening typical for all Units

VERTICAL ROUGH OPENING

Premium Wood

Siteline EX Primed Casement Windows

Architectural Detail ManualAugust 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-70

BAY & BOW WINDOW ROUGH OPENINGS

NO TRIM

Vertical Masonry Opening will be 1/2” [13]larger than the Overall Unit Size.

VERTICAL ROUGH OPENINGRough Opening typical for all Units

HORIZONTAL ROUGH OPENINGRough Opening typical for all Units

with Brickmould

4, 5 & 6 WIDE BOWS

45° Bay Shown30° & 45° BAYS

without trim4 Wide Bow Shown

Rough Opening

Rough Opening

BASI

CU

NIT

FRA

ME

HEI

GH

T

OV

ERA

LLFR

AM

EH

EIG

HT

+1-

1/2”

OV

ERA

LLRO

UG

HO

PEN

ING

+3/

4”

OV

ERA

LLU

NIT

HEI

GH

T(B

ASI

CU

NIT

FRA

ME

HEI

GH

T+

3/4”

[19]

3/4” [19]

3/4” [19]

3/8” [10]

Exterior of Wall

Rough Opening ismeasured from thepoint the frame intersectsthe jamb aligner.

Exterior of Wall

3/8” [10] Rough Opening ismeasured from thepoint the frame intersectsthe jamb aligner.

SEATBOARD

HEADBOARD

Premium Wood

Siteline EX Primed Casement Windows

Architectural Detail ManualAugust 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-71

30_ ANGLE BAY UNIT

Uni

tSi

ze

Sash

Size

Gla

ssSi

ze

Day

light

Ope

ning

7/16”

1 9/16”

1 7/8”

7/16”

1 9/16”

2 7/16”

5 1/4”1 1/8” 4 3/16”

7/16”3 3/4”

VERTICAL SECTION

5 1/2”

1 5/16”4 3/16”

3 3/4”7/16”

Basi

cU

nit

Size

Ove

rall

Fram

eH

eigh

t+

1-1/

2”

Ove

rall

Roug

hO

peni

ng+

3/4”

3/4”

Premium Wood

Siteline EX Primed Casement Windows

SCALE: 3” = 1’

Architectural Detail ManualAugust 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-72

30_ ANGLE BAY UNIT

HORIZONTAL SECTION

Daylight Opening

Glass Size

Sash Size

3/4”1 9/16” 7/16”

7/16”

1 9/16”

1 9/16”

7/16”

1 13/16”

Sash Size

Glass Size

Daylight Opening

Unit Size

Rough Opening

Seatboard Size

Premium Wood

Siteline EX Primed Casement Windows

SCALE: 3” = 1’

Architectural Detail ManualAugust 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-73

45_ ANGLE BAY UNIT

Uni

tSi

ze

Sash

Size

Gla

ssSi

ze

Day

light

Ope

ning

7/16”

1 9/16”

1 7/8”

7/16”

1 9/16”

2 7/16”

5 1/4”1 1/8” 4 3/16”

7/16”3 3/4”

VERTICAL SECTION

5 1/2”

1 5/16”4 3/16”

3 3/4”7/16”

Basi

cU

nit

Size

Ove

rall

Fram

eH

eigh

t+

1-1/

2”

Ove

rall

Roug

hO

peni

ng+

3/4”

3/4”

Premium Wood

Siteline EX Primed Casement Windows

SCALE: 3” = 1’

Architectural Detail ManualAugust 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-74

45_ ANGLE BAY UNIT

HORIZONTAL SECTION

3/4”

7/16”1 9/16”

7/16”

1 9/16”

7/16”

1 9/16”

2”

Sash Size

Glass Size

Daylight Opening

Unit Size

Rough Opening

Seatboard

Sash SizeGlass Size

DaylightOpening

Premium Wood

Siteline EX Primed Casement Windows

SCALE: 3” = 1’

Architectural Detail ManualAugust 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-75

BOW UNIT

Uni

tSi

ze

Sash

Size

Gla

ssSi

ze

Day

light

Ope

ning

7/16”

1 9/16”

1 7/8”

7/16”

1 9/16”

2 7/16”

5 1/4”1 1/8” 4 3/16”

7/16”3 3/4”

VERTICAL SECTION

5 1/2”

1 5/16”4 3/16”

3 3/4”7/16”

Basi

cU

nit

Size

Ove

rall

Fram

eH

eigh

t+

1-1/

2”

Ove

rall

Roug

hO

peni

ng+

3/4”

3/4”

Premium Wood

Siteline EX Primed Casement Windows

SCALE: 3” = 1’

Architectural Detail ManualAugust 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-76

BOW UNIT - 3-WIDE

HORIZONTAL SECTION

1”

3/4”

Daylight Opening

Glass Size

Sash Size

7/16”

1 9/16” 7/16”

1 9/16”

Sash Size

Glass Size

Daylight Opening

Unit Size

Rough Opening

Seatboard

Premium Wood

Siteline EX Primed Casement Windows

SCALE: 3” = 1’

Architectural Detail ManualAugust 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-77

BOW UNIT - 4-WIDE

HORIZONTAL SECTION

3/4”

3/4”Daylight Opening

Glass Size

Sash Size

7/16”1 9/16”

7/16”

1 9/16”

Daylight Opening

Glass Size

Sash Size

7/16”

1 9/16”7/16”

1 9/16”

1 1/4”

Unit Size

Rough Opening

Seatboard

Premium Wood

Siteline EX Primed Casement Windows

SCALE: 3” = 1’

Architectural Detail ManualAugust 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-78

BOW UNIT - 5-WIDE

HORIZONTAL SECTION

3/4”

Daylight

Glass Size

Sash Size3/4”

Glass Size

Sash Size

7/16”

1 9/16”

7/16”

1 9/16”

7/16”

1 9/16” 7/16”

1 9/16”7/16”

1 9/16”

1 1/2”

Unit Size

Sash Size

Glass Size

Daylight Opening

Seatboard

Frame Size

Opening

DaylightOpening

Premium Wood

Siteline EX Primed Casement Windows

SCALE: 3” = 1’

Architectural Detail ManualAugust 2010 JELD-WEN reserves the right to change specifications without notice. Page 2-79

BOW UNIT - 6-WIDE

3/4”

Day

light

Gla

ssSi

ze

Sash

Size

7/16

”1

9/16

7/16

19/

16”

3/4”

Gla

ssSi

ze

Sash

Size

7/16

”1

9/16

”7/

16”

19/

16”

3/4”

Gla

ssSi

ze

Sash

Size

7/16

19/

16”

7/16

19/

16”

3/4”

7/16

19/

16”

111

/16”

Roug

hO

peni

ng

Seat

boar

d

Uni

tSi

ze

Sash

Size

Gla

ssSi

ze

Day

light

Ope

ning

Ope

ning

Day

light

Ope

ning

Day

light

Ope

ning

HO

RIZ

ON

TAL

SEC

TIO

N

Premium Wood

Siteline EX Primed Casement Windows

SCALE: 3” = 1’