Marvin Architectural Detail Manual2012−04−30
CHAPTER 1A
CLAD ULTIMATE CASEMENT (CUCA)CLAD ULTIMATE PUSH OUT CASEMENT (CUPCA)CLAD ULTIMATE CASEMENT PICTURE (CUCAP)
CLAD ULTIMATE PUSH OUT CASEMENT PICTURE (CUPCAP)
Product InformationUnit Features / Egress Information 1A.2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Egress Opening Measurements CUCA 1A.3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Vent Opening Measurements CUCA 1A.4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Daylight Opening Measurements CUCA 1A.5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Egress Opening Measurements CUPCA 1A.6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Vent Opening Measurements CUPCA 1A.7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Daylight Opening Measurements CUPCA 1A.8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Daylight Opening Measurements CUCAP and CUPCAP 1A.9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NFRC Thermal Performance CUCA 1A.11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NFRC Thermal Performance CUPCA 1A.12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NFRC Thermal Performance Impact Zone 3 1A.13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NFRC Thermal Performance CUCAP 1A.14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NFRC Thermal Performance CUPCAP 1A.16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NFRC Thermal Performance CUPCAP 3/4″ Impact Zone 3 1A.18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Certified Sizes and Ratings, Minimum and Maximum Guidelines 1A.20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Certified Sizes and Ratings, Minimum and Maximum Guidelines −CUCA − Impact Zone 3 1A.22. . . . . . . . . . .Measurement Conversions 1A.23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Standard Sizes − CUCA and CUPCA 1A.25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Standard Sizes − CUCAP and CUPCAP 1A.27. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Section Details 1A.31. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Mulling Guidelines 1A.39. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Mullions 1A.40. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Divided Lite Options 1A.42. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NOTE:
Specifications and technical data are subject to change without notice.Allow 1/16″ (2) tolerance on all measurements.Metric measurements are shown in parenthesis.For accessories dimensions and applications see the Accessories section of this manual.For technical assistance about Marvin products you may call 1−800−346−3363 or visit our website: www.marvin.com.For product specifications please refer to the CSI Product Specifications on our website: www.marvin.com or contact yourMarvin Representative.
ClearOpening
Width
ClearOpeningHeight
International Building Code − 2003 and 2006Section 1009 Emergency Escape and Rescue
1009.2 Minimum size: Emergency escape and rescue openings shall have a minimum net clearopening of 5.7 square feet (0.53 m2). Exception: The minimum net clear opening for emergencyescape and rescue openings on the ground level at grade is 5.0 square feet (0.46 m2).
1009.2.1 Minimum dimensions: The minimum net clear opening height dimension shall be 24inches (610 mm). The net clear opening width dimension shall be 20 inches (508 mm). The netclear opening dimensions shall be the result of normal operation of the opening.
1009.3 Maximum height from the floor: Emergency escape and rescue opening shall have thebottom of the clear opening not greater than 44 inches (1118 mm) measured from the floor.
1009.4 Operational constraints: Emergency escape and rescue openings shall be operationalfrom the inside of the room without the use of keys or tools. Bars, grilles, grates, or similar de-vices are permitted to be placed over emergency escape and rescue openings provided theminimum net clear opening size complies with Section 1009.2 and such devices shall be releas-able or removable from the inside without the use of a key, tool, or force greater than that which isrequired for normal operation of the escape and rescue opening.
Code restrictions may vary depending on your local building codes.
Egress InformationUltimate Push Out Casement − OperatorUltimate Casement − Operator
ClearOpening
Width
ClearOpeningHeight
1A.211708324
Marvin Architectural Detail Manual2012−04−30
CUCA Hardware:� Casement operator includes a crank hardware system that allows the window to open to a full 90 degrees with a minimal reduction of
egress net clear opening. Single arm operators, steel coated with E−Gard�. Operation force at handle is 5lbs. or less.� Casement hinges allow the user the ability to slide the sash across the frame opening so the sash exterior will rotate toward the user
for easy washability. Hinges are steel coated with E−Gard� and the standard track is stainless steel. Frame OM width of 20″ (508) tounder 24″ (610) use 18″ (457) wash/egress hinge. Frame OM width greater than 24″ (610) use 22″ (559) wash/egress hinge. FrameOM width less than 20″ (508) use dyad hinge (dyad hinges do not have special easy washability feature) .
� Folding handles are standard.� Locks used are a concealed multi−point sequential system.� Stainless Steel packages are available.� Factory installed Window Opening Control Device (WOCD)
� The standard operation of the WOCD shall limit the operation of the sash to an opening of 4” or less. The tether shall be able todetach from the lock housing by a two step function actuation to allow normal operation of the unit. The tether shall be able tore−engage when the unit is fully closed.
� Hardware meet the ASTM F2090-10� Minimum operable unit size: 26″ (660) x 19 1/4″ (489)� Maximum operable unit size: 40″ (1016) x 92” (2337) - unit size width is greater than 36″� Maximum operable unit size: 36″ (914) x 96 1/8″ (2442) - unit size width is less than or equal to 36″� WOCD locking assembly: Factory installed. Die Cast. Color: Satin Taupe, Bronze, White, Oil-Rubbed Bronze, Brass, Satin Nickel,
Antique Brass, Polished Chrome, Satin Chrome.� WOCD tether assembly: factory installed. Glass filled nylon. Color: E-Gard� color match.
� Power Drive Operator: (Optional)� Motor is metal cased.� Motor cover is plastic; Cover colors: Satin Taupe, White and Bronze� Field Installed� Available for all size CN16 and wider.� Remote control available as an option
� Aluminum Pole Crank (Optional)� Color is mill finish� Sizes: 60″ (1524), 96″ (2438), 138″ (3505)
NOTE: Neither Power Drive and Pole Crank operate locks.
CUPCA Hardware:� Multi−point sequential system with a single lock handle actuation. Stainless Steel option available.� Sequential multi−lock uses 2, 4, or 5 locking points depending on unit size.� Friction limiter is used to hold sash in place and allow sash to lock open at multiple locations. Stainless Steel option available.� Hinges allow the user the ability to slide sash across frame opening which causes the sash exterior to rotate towards the user for easy
washability. Stainless Steel option available.� Units under 20″ (508) width OM do not have the easy wash hinges.
CLAD ULTIMATE CASEMENT/PUSH OUT CASEMENT
UNIT FEATURES
1A.311708324
Marvin Architectural Detail Manual2011−08−23
CUCAEgress OpeningMeasurements
Operating Casement
Width
CN 16 18 20 24 26 28
FS 1−4 (406) 1−6 (457) 1−8 (508) 2−0 (610) 2−2 (660) 2−4 (711)
HeightClear
Opening 6 13/32 (163) 8 13/32 (213) 1−0 7/8 (327) 1−4 7/8 (429) 1−6 7/8 (480) 1−8 7/8 (531)
CN FSClear
Opening Square Feet (Square Meters)14 1−1 1/8 (333) 0−8 (203) 0.36 (0.03) 0.47 (0.04) 0.72 (0.07) 0.94 (0.09) 1.05 (0.10) 1.16 (0.11)16 1−3 1/8 (384) 0−10 (254) 0.44 (0.04) 0.58 (0.05) 0.90 (0.08) 1.17 (0.11) 1.31 (0.12) 1.45 (0.14)18 1−5 1/8 (435) 1−0 (305) 0.53 (0.05) 0.70 (0.07) 1.08 (0.10) 1.41 (0.13) 1.58 (0.15) 1.74 (0.16)20 1−7 1/8 (486) 1−2 (356) 0.62 (0.06) 0.82 (0.08) 1.25 (0.12) 1.64 (0.15) 1.84 (0.17) 2.03 (0.19)24 1−11 1/8 (587) 1−6 (457) 0.80 (0.07) 1.05 (0.10) 1.61 (0.15) 2.11 (0.20) 2.36 (0.22) 2.61 (0.24)28 2−3 1/8 (689) 1−10 (559) 0.98 (0.09) 1.28 (0.12) 1.97 (0.18) 2.58 (0.24) 2.89 (0.27) 3.19 (0.30)32 2−7 1/8 (791) 2−2 (661) 1.16 (0.11) 1.52 (0.14) 2.33 (0.22) 3.05 (0.28) 3.41 (0.32) 3.77 (0.35)36 2−11 1/8 (892) 2−6 (762) 1.33 (0.12) 1.75 (0.16) 2.69 (0.25) 3.52 (0.33) 3.94 (0.37) 4.35 (0.40)40 3−3 1/8 (994) 2−10 (864) 1.51 (0.14) 1.98 (0.18) 3.04 (0.28) 3.99 (0.37) 4.46 (0.41) 4.93 (0.46)44 3−7 1/8 (1095) 3−2 (965) 1.69 (0.16) 2.22 (0.21) 3.40 (0.32) 4.46 (0.41) 4.99 (0.46) 5.51 (0.51)48 3−11 1/8 (1197) 3−6 (1067) 1.87 (0.17) 2.45 (0.23) 3.76 (0.35) 4.93 (0.46) 5.51 (0.51) 6.09E (0.57)54 4−5 1/8 (1349) 4−0 (1219) 2.13 (0.20) 2.80 (0.26) 4.30 (0.40) 5.63 (0.52) 6.30 (0.59) 6.96E (0.65)56 4−7 1/8 (1400) 4−2 (1270) 2.22 (0.21) 2.92 (0.27) 4.48 (0.42) 5.87 (0.54) 6.56 (0.61) 7.25E (0.67)60 4−11 1/8 (1502) 4−6 (1372) 2.40 (0.22) 3.15 (0.29) 4.83 (0.45) 6.33 (0.59) 7.09 (0.66) 7.84E (0.73)64 5−3 1/8 (1603) 4−10 (1473) 2.58 (0.24) 3.38 (0.31) 5.19 (0.48) 6.80 (0.63) 7.61 (0.71) 8.42E (0.78)72 5−11 1/8 (1807) 5−6 (1677) 2.93 (0.27) 3.85 (0.36) 5.91 (0.55) 7.74 (0.72) 8.66 (0.80) 9.58E (0.89)78 6−5 1/8 (1959) 6−0 (1829) 3.20 (0.30) 4.20 (0.39) 6.45 (0.60) 8.45 (0.78) 9.45 (0.88) 10.45E(0.97)84 6−11 1/8 (2111) 6−6 (1981) 3.47 (0.32) 4.55 (0.42) 6.98 (0.65) 9.15 (0.85) 10.23 (0.95) 11.32E(1.05)92 7−7 1/8 (2315) 7−2 (2185) 3.82 (0.36) 5.02 (0.47) 7.70 (0.72) 10.09 (0.94) 11.28 (1.05) 12.48E(1.16)96 7−11 1/8 (2416) 7−6 (2286) 4.00 (0.37) 5.25 (0.49) 8.06 (0.75) 10.56 (0.98) 11.81 (1.10) 13.06E(1.21)
CUCAEgress OpeningMeasurements
Operating Casement
Width
CN 30 32 36 40
FS 2−6 (762) 2−8 (813) 3−0 (914) 3−4 (1016)
HeightClear
Opening 1−10 7/8 (581) 2−0 7/8 (632) 2−4 7/8 (734) 2−8 7/8 (835)
CN FSClear
Opening Square Feet (Square Meters)14 1−1 1/8 (333) 0−8 (203) 1.27 (0.12) 1.38 (0.13) 1.61 (0.15) 1.83 (0.17)16 1−3 1/8 (384) 0−10 (254) 1.59 (0.15) 1.73 (0.16) 2.01 (0.19) 2.29 (0.21)18 1−5 1/8 (435) 1−0 (305) 1.91 (0.18) 2.08 (0.19) 2.41 (0.22) 2.74 (0.25)20 1−7 1/8 (486) 1−2 (356) 2.23 (0.21) 2.42 (0.21) 2.81 (0.26) 3.20 (0.30)24 1−11 1/8 (587) 1−6 (457) 2.86 (0.27) 3.11 (0.29) 3.61 (0.34) 4.11 (0.38)28 2−3 1/8 (689) 1−10 (559) 3.50 (0.33) 3.80 (0.35) 4.42 (0.41) 5.03 (0.47)32 2−7 1/8 (791) 2−2 (661) 4.13 (0.38) 4.50 (0.42) 5.22 (0.48) 5.94E (0.55)36 2−11 1/8 (892) 2−6 (762) 4.77 (0.44) 5.19 (0.48) 6.02E (0.56) 6.85E (0.64)40 3−3 1/8 (994) 2−10 (864) 5.41 (0.50) 5.88E (0.55) 6.82E (0.63) 7.77E (0.72)44 3−7 1/8 (1095) 3−2 (965) 6.04E (0.56) 6.57E (0.61) 7.63E (0.71) 8.68E (0.81)48 3−11 1/8 (1197) 3−6 (1067) 6.68E (0.62) 7.26E (0.67) 8.43E (0.78) 9.60E (0.89)54 4−5 1/8 (1349) 4−0 (1219) 7.63E (0.71) 8.30E (0.77) 9.63E (0.89) 10.97E(1.02)56 4−7 1/8 (1400) 4−2 (1270) 7.95E (0.74) 8.64E (0.80) 10.03E(0.93) 11.42E(1.06)60 4−11 1/8 (1502) 4−6 (1372) 8.59E (0.80) 9.34E (0.87) 10.84E(1.01) 12.34E(1.15)64 5−3 1/8 (1603) 4−10 (1473) 9.22E (0.86) 10.03E(0.93) 11.64E(1.08) 13.25E(1.23)72 5−11 1/8 (1807) 5−6 (1677) 10.49E(0.97) 11.41E(1.06) 13.24E(1.23) 15.08E(1.40)78 6−5 1/8 (1959) 6−0 (1829) 11.45E(1.06) 12.45E(1.16) 14.45E(1.34) 16.45E(1.53)84 6−11 1/8 (2111) 6−6 (1981) 12.40E(1.15) 13.48E(1.25) 15.65E(1.45) 17.82E(1.66)92 7−7 1/8 (2315) 7−2 (2185) 13.67E(1.27) 14.87E(1.38) 17.26E(1.60) 19.65E(1.83)96 7−11 1/8 (2416) 7−6 (2286) 14.31E(1.33) 15.56E(1.45) 18.06E(1.68) N/A
NOTE: “E” indicates a window that meets the requirements for Egress.Please note that the top of the sill must be no more than 44″ from the floor.
NOTE: Standard bottom rail
CLAD ULTIMATE CASEMENT
EGRESS OPENING MEASUREMENTS
1A.411708324
Marvin Architectural Detail Manual2011−08−24
CUCAVent OpeningMeasurements
Operating Casement
Width
CN 16 18 20 24 26 28
FS 1−4 (406) 1−6 (457) 1−8 (508) 2−0 (610) 2−2 (660) 2−4 (711)
HeightVent
Opening 0−11 (279) 1−1 (330) 1−3 (381) 1−7 (483) 1−9 (533) 1−11 (584)
CN FSVent
Opening Square Feet (Square Meters)14 1−1 1/8 (333) 0−8 (203) 0.61 (0.06) 0.72 (0.07) 0.84 (0.08) 1.06 (0.10) 1.17 (0.11) 1.28 (0.12)16 1−3 1/8 (384) 0−10 (254) 0.77 (0.07) 0.90 (0.08) 1.04 (0.10) 1.32 (0.12) 1.46 (0.14) 1.60 (0.15)18 1−5 1/8 (435) 1−0 (305) 0.92 (0.09) 1.09 (0.10) 1.25 (0.12) 1.59 (0.15) 1.75 (0.16) 1.92 (0.18)20 1−7 1/8 (486) 1−2 (356) 1.07 (0.10) 1.27 (0.12) 1.46 (0.14) 1.85 (0.17) 2.04 (0.19) 2.24 (0.21)24 1−11 1/8 (587) 1−6 (457) 1.38 (0.13) 1.63 (0.15) 1.88 (0.17) 2.38 (0.22) 2.63 (0.24) 2.88 (0.27)28 2−3 1/8 (689) 1−10 (559) 1.68 (0.16) 1.99 (0.18) 2.30 (0.21) 2.91 (0.27) 3.21 (0.30) 3.52 (0.33)32 2−7 1/8 (791) 2−2 (661) 1.99 (0.18) 2.35 (0.22) 2.71 (0.25) 3.43 (0.32) 3.80 (0.35) 4.16 (0.39)36 2−11 1/8 (892) 2−6 (762) 2.30 (0.21) 2.71 (0.25) 3.13 (0.29) 3.96 (0.37) 4.38 (0.41) 4.80 (0.45)40 3−3 1/8 (994) 2−10 (864) 2.60 (0.24) 3.07 (0.29) 3.55 (0.33) 4.49 (0.42) 4.96 (0.46) 5.44 (0.51)44 3−7 1/8 (1095) 3−2 (965) 2.91 (0.27) 3.44 (0.32) 3.96 (0.37) 5.02 (0.47) 5.55 (0.52) 6.08 (0.56)48 3−11 1/8 (1197) 3−6 (1067) 3.21 (0.30) 3.80 (0.35) 4.38 (0.41) 5.55 (0.52) 6.13 (0.57) 6.71 (0.62)54 4−5 1/8 (1349) 4−0 (1219) 3.67 (0.34) 4.34 (0.40) 5.01 (0.47) 6.34 (0.59) 7.01 (0.65) 7.67 (0.71)56 4−7 1/8 (1400) 4−2 (1270) 3.83 (0.36) 4.52 (0.42) 5.22 (0.48) 6.60 (0.61) 7.30 (0.68) 7.99 (0.74)60 4−11 1/8 (1502) 4−6 (1372) 4.13 (0.38) 4.88 (0.45) 5.63 (0.52) 7.13 (0.66) 7.88 (0.73) 8.63 (0.80)64 5−3 1/8 (1603) 4−10 (1473) 4.44 (0.41) 5.24 (0.49) 6.05 (0.56) 7.66 (0.71) 8.47 (0.79) 9.27 (0.86)72 5−11 1/8 (1807) 5−6 (1677) 5.05 (0.47) 5.97 (0.55) 6.88 (0.64) 8.72 (0.81) 9.63 (0.89) 10.55 (0.98)78 6−5 1/8 (1959) 6−0 (1829) 5.51 (0.51) 6.51 (0.60) 7.51 (0.70) 9.51 (0.88) 10.51 (0.98) 11.51 (1.07)84 6−11 1/8 (2111) 6−6 (1981) 5.97 (0.55) 7.05 (0.65) 8.13 (0.76) 10.30 (0.99) 11.39 (1.06) 12.47 (1.16)92 7−7 1/8 (2315) 7−2 (2185) 6.58 (0.61) 7.77 (0.72) 8.97 (0.83) 11.36 (1.06) 12.55 (1.17) 13.75 (1.28)96 7−11 1/8 (2416) 7−6 (2286) 6.89 (0.64) 8.14 (0.76) 9.39 (0.87) 11.89 (1.10) 13.14 (1.22) 14.39 (1.34)
CUCAVent OpeningMeasurements
Operating Casement
Width
CN 30 32 36 40
FS 30 (762) 32 (813) 36 (914) 40 (1016)
HeightVent
Opening 25 (635) 27 (686) 31 (787) 35 (889)
CN FSVent
Opening Square Feet (Square Meters)14 1−1 1/8 (333) 0−8 (203) 1.39 (0.13) 1.50 (0.14) 1.73 (0.16) 1.95 (0.18)16 1−3 1/8 (384) 0−10 (254) 1.74 (0.16) 1.88 (0.17) 2.16 (0.20) 2.43 (0.23)18 1−5 1/8 (435) 1−0 (305) 2.09 (0.19) 2.25 (0.21) 2.59 (0.24) 2.92 (0.27)20 1−7 1/8 (486) 1−2 (356) 2.43 (0.23) 2.63 (0.24) 3.02 (0.28) 3.41 (0.32)24 1−11 1/8 (587) 1−6 (457) 3.13 (0.29) 3.38 (0.31) 3.88 (0.36) 4.38 (0.41)28 2−3 1/8 (689) 1−10 (559) 3.82 (0.35) 4.13 (0.38) 4.74 (0.44) 5.35 (0.50)32 2−7 1/8 (791) 2−2 (661) 4.52 (0.42) 4.88 (0.45) 5.60 (0.52) 6.33 (0.59)36 2−11 1/8 (892) 2−6 (762) 5.21 (0.48) 5.63 (0.52) 6.46 (0.60) 7.30 (0.68)40 3−3 1/8 (994) 2−10 (864) 5.91 (0.55) 6.38 (0.59) 7.33 (0.68) 8.27 (0.77)44 3−7 1/8 (1095) 3−2 (965) 6.60 (0.61) 7.13 (0.66) 8.17 (0.76) 9.24 (0.86)48 3−11 1/8 (1197) 3−6 (1067) 7.30 (0.68) 7.88 (0.73) 9.05 (0.84) 10.22 (0.95)54 4−5 1/8 (1349) 4−0 (1219) 8.34 (0.77) 9.01 (0.84) 10.34 (0.96) 11.67 (1.08)56 4−7 1/8 (1400) 4−2 (1270) 8.69 (0.81) 9.38 (0.87) 10.77 (1.00) 12.16 (1.13)60 4−11 1/8 (1502) 4−6 (1372) 9.38 (0.87) 10.13 (0.94) 11.63 (1.08) 13.13 (1.22)64 5−3 1/8 (1603) 4−10 (1473) 10.08 (0.94) 10.88 (1.01) 12.49 (1.16) 14.11 (1.31)72 5−11 1/8 (1807) 5−6 (1677) 11.47 (1.07) 12.38 (1.15) 14.22 (1.32) 16.05 (1.49)78 6−5 1/8 (1959) 6−0 (1829) 12.51 (1.16) 13.51 (1.26) 15.51 (1.44) 17.51 (1.63)84 6−11 1/8 (2111) 6−6 (1981) 13.55 (1.26) 14.64 (1.36) 16.80 (1.56) 18.97 (1.76)92 7−7 1/8 (2315) 7−2 (2185) 14.94 (1.39) 16.14 (1.50) 18.53 (1.72) 20.92 (1.94)96 7−11 1/8 (2416) 7−6 (2286) 15.64 (1.45) 16.89 (1.57) 19.39 (1.80) N/A
NOTE: Standard bottom rail
CLAD ULTIMATE CASEMENT
VENT OPENING MEASUREMENTS
1A.511708324
Marvin Architectural Detail Manual2011−08−24
CUCADaylight MeasurementOperating Casement
Width
CN 16 18 20 24 26 28
FS 1−4 (406) 1−6 (457) 1−8 (508) 2−0 (610) 2−2 (660) 2−4 (711)
Height DLO 10 3/16 (259) 1−0 3/16 (310) 1−2 3/16 (360) 1−6 3/16 (462) 1−8 3/16 (513) 1−10 3/16 (564)
CNFS
HeightDLO
Height Square Feet (Square Meters)
14 1−1 1/8 (333) 0−7 5/16 (186) 0.52 (0.05) 0.62 (0.06) 0.72 (0.07) 0.92 (0.09) 1.03 (0.10) 1.13 (0.10)
16 1−3 1/8 (384) 0−9 5/16 (237) 0.66 (0.06) 0.79 (0.07) 0.92 (0.09) 1.18 (0.11) 1.31 (0.12) 1.43 (0.13)
18 1−5 1/8 (435) 0−11 5/16 (287) 0.80 (0.07) 0.96 (0.09) 1.11 (0.10) 1.43 (0.13) 1.59 (0.15) 1.74 (0.16)
20 1−7 1/8 (486) 1−1 5/16 (338) 0.94 (0.09) 1.13 (0.10) 1.31 (0.12) 1.68 (0.16) 1.87 (0.17) 2.05 (0.19)
24 1−11 1/8 (587) 1−5 5/16 (440) 1.22 (0.11) 1.47 (0.14) 1.71 (0.16) 2.19 (0.20) 2.43 (0.23) 2.67 (0.25)
28 2−3 1/8 (689) 1−9 5/16 (541) 1.51 (0.14) 1.80 (0.17) 2.10 (0.20) 2.69 (0.25) 2.99 (0.28) 3.28 (0.31)
32 2−7 1/8 (791) 2−1 5/16 (643) 1.79 (0.17) 2.14 (0.20) 2.49 (0.23) 3.20 (0.30) 3.55 (0.33) 3.90 (0.36)
36 2−11 1/8 (892) 2−5 5/16 (745) 2.07 (0.19) 2.48 (0.23) 2.89 (0.27) 3.70 (0.34) 4.11 (0.38) 4.52 (0.42)
40 3−3 1/8 (994) 2−9 5/16 (846) 2.36 (0.22) 2.82 (0.26) 3.28 (0.30) 4.21 (0.39) 4.67 (0.43) 5.13 (0.48)
44 3−7 1/8 (1095) 3−1 5/16 (948) 2.64 (0.25) 3.16 (0.29) 3.68 (0.34) 4.71 (0.44) 5.23 (0.49) 5.75 (0.53)
48 3−11 1/8 (1197) 3−5 5/16 (1049) 2.92 (0.27) 3.50 (0.32) 4.07 (0.38) 5.22 (0.48) 5.79 (0.54) 6.37 (0.59)
54 4−5 1/8 (1349) 3−11 5/16 (1202) 3.35 (0.31) 4.00 (0.37) 4.66 (0.43) 5.98 (0.56) 6.63 (0.62) 7.29 (0.68)
56 4−7 1/8 (1400) 4−1 5/16 (1253) 3.49 (0.32) 4.17 (0.39) 4.86 (0.45) 6.23 (0.58) 6.91 (0.64) 7.60 (0.71)
60 4−11 1/8 (1502) 4−5 5/16 (1354) 3.77 (0.35) 4.51 (0.42) 5.25 (0.49) 6.73 (0.63) 7.47 (0.69) 8.21 (0.76)
64 5−31/8 (1603) 4−9 5/16 (1456) 4.05 (0.38) 4.85 (0.45) 5.65 (0.52) 7.24 (0.67) 8.03 (0.75) 8.83 (0.82)
72 5−11 1/8 (1807) 5−5 5/16 (1659) 4.62 (0.43) 5.53 (0.51) 6.43 (0.60) 8.25 (0.78) 9.16 (0.85) 10.06 (0.93)
78 6−5 1/8 (1959) 5−11 5/16 (1811) 5.04 (0.47) 6.04 (0.56) 7.03 (0.65) 9.01 (0.84) 10.00 (0.93) 10.99 (1.02)
84 6−11 1/8 (2111) 6−3 5/16 (1964) 5.47 (0.51) 6.54 (0.61) 7.62 (0.71) 9.76 (0.91) 10.84 (1.01) 11.91 (1.11)
92 7−7 1/8 (2315) 7−1 5/16 (2167) 6.04 (0.56) 7.22 (0.67) 8.41 (0.78) 10.77 (1.00) 11.96 (1.11) 13.14 (1.22)
96 7−11 1/8 (2416) 7−5 5/16 (2269) 6.32 (0.59) 7.56 (0.70) 8.80 (0.82) 11.28 (1.05) 12.52 (1.16) 13.76 (1.28)
CUCADaylight MeasurementOperating Casement
WidthCN 30 32 36 40FS 2−6 (762) 2−8 (813) 3−0 (914) 3−4 (1016)
Height DLO 2−0 3/16 (614) 2−2 3/16 (665) 2−6 3/16 (767) 2−10 3/16 (868)
CNFS
HeightDLO
Height Square Feet (Square Meters)14 1−1 1/8 (333) 0−7 5/16 (186) 1.23 (0.11) 1.33 (0.12) 1.53 (0.14) 1.74 (0.16)16 1−3 1/8 (384) 0−9 5/16 (237) 1.56 (0.15) 1.69 (0.16) 1.95 (0.18) 2.21 (0.21)18 1−5 1/8 (435) 0−11 5/16 (287) 1.90 (0.18) 2.06 (0.19) 2.37 (0.22) 2.69 (0.25)20 1−7 1/8 (486) 1−1 5/16 (338) 2.24 (0.21) 2.42 (0.22) 2.79 (0.26) 3.16 (0.29)24 1−11 1/8 (587) 1−5 5/16 (440) 2.91 (0.27) 3.15 (0.29) 3.63 (0.34) 4.11 (0.38)28 2−3 1/8 (689) 1−9 5/16 (541) 3.58 (0.33) 3.88 (0.36) 4.47 (0.42) 5.06 (0.47)32 2−7 1/8 (791) 2−1 5/16 (643) 4.25 (0.40) 4.60 (0.43) 5.31 (0.49) 6.01 (0.56)36 2−11 1/8 (892) 2−5 5/16 (745) 4.92 (0.46) 5.33 (0.50) 6.14 (0.57) 6.96 (0.65)40 3−3 1/8 (994) 2−9 5/16 (846) 5.60 (0.52) 6.06 (0.56) 6.98 (0.65) 7.91 (0.73)44 3−7 1/8 (1095) 3−1 5/16 (948) 6.27 (0.58) 6.79 (0.63) 7.82 (0.73) 8.86 (0.82)48 3−11 1/8 (1197) 3−5 5/16 (1049) 6.94 (0.64) 7.51 (0.70) 8.66 (0.81) 9.81 (0.91)54 4−5 1/8 (1349) 3−11 5/16 (1202) 7.95 (0.74) 8.60 (0.80) 9.92 (0.92) 11.23 (1.04)56 4−7 1/8 (1400) 4−1 5/16 (1253) 8.28 (0.77) 8.97 (0.83) 10.34 (0.96) 11.71 (1.09)60 4−11 1/8 (1502) 4−5 5/16 (1354) 8.96 (0.83) 9.70 (0.90) 11.18 (1.04) 12.66 (1.18)64 5−31/8 (1603) 4−9 5/16 (1456) 9.63 (0.89) 10.42 (0.97) 12.01 (1.12) 13.61 (1.26)72 5−11 1/8 (1807) 5−5 5/16 (1659) 10.97 (1.02) 11.88 (1.10) 13.69 (1.27) 15.51 (1.44)78 6−5 1/8 (1959) 5−11 5/16 (1811) 11.98 (1.11) 12.97 (1.20) 14.95 (1.39) 16.93 (1.57)84 6−11 1/8 (2111) 6−3 5/16 (1964) 12.99 (1.21) 14.06 (1.31) 16.21 (1.51) 18.35 (1.71)92 7−7 1/8 (2315) 7−1 5/16 (2167) 14.33 (1.33) 15.52 (1.44) 17.88 (1.66) 20.25 (1.88)
96 7−11 1/8 (2416) 7−5 5/16 (2269) 15.00 (1.39) 16.24 (1.51) 18.72 (1.74) N/A
NOTE: Standard bottom rail
CLAD ULTIMATE CASEMENT
DAYLIGHT OPENING MEASUREMENTS
1A.611708324
Marvin Architectural Detail Manual2011−08−25
CUPCAEgress OpeningMeasurements
Operating Casement
Width
CN 16 18 20 24 26 28
FS 1−4 (406) 1−6 (457) 1−8 (508) 2−0 (610) 2−2 (660) 2−4 (711)
HeightClear
Opening 7 21/64 (186) 9 21/64 (237) 1−1 13/16 (351) 1−5 13/16 (453) 1−7 13/16 (660) 1−9 13/16 (554)
CN FSClear
Opening Square Feet (Square Meters)16 1−3 1/8 (384) 0−11 (279) 0.56 (0.05) 0.72 (0.07) 1.06 (0.10) 1.37 (0.13) 1.52 (0.14) 1.67 (0.16)18 1−5 1/8 (435) 1−1 (330) 0.66 (0.06) 0.85 (0.08) 1.25 (0.12) 1.61 (0.15) 1.80 (0.17) 1.98 (0.18)20 1−7 1/8 (486) 1−3 (381) 0.77 (0.07) 0.97 (0.09) 1.44 (0.13) 1.86 (0.17) 2.07 (0.19) 2.28 (0.21)24 1−11 1/8 (587) 1−7 (483) 0.97 (0.09) 1.23 (0.11) 1.83 (0.17) 2.36 (0.22) 2.62 (0.24) 2.89 (0.27)28 2−3 1/8 (689) 1−11 (584) 1.17 (0.11) 1.49 (0.14) 2.21 (0.21) 2.85 (0.26) 3.17 (0.29) 3.49 (0.32)32 2−7 1/8 (791) 2−3 (686) 1.38 (0.13) 1.75 (0.16) 2.60 (0.24) 3.35 (0.31) 3.72 (0.35) 4.10 (0.38)36 2−11 1/8 (892) 2−7 (787) 1.58 (0.15) 2.01 (0.19) 2.98 (0.28) 3.84 (0.36) 4.27 (0.40) 4.70 (.044)40 3−3 1/8 (994) 2−11 (889) 1.78 (0.17) 2.27 (0.21) 3.36 (0.31) 4.34 (0.40) 4.82 (0.45) 5.31 (0.49)44 3−7 1/8 (1095) 3−3 (991) 1.99 (0.18) 2.53 (0.23) 3.75 (0.35) 4.83 (0.45) 5.37 (0.50) 5.92E (0.55)48 3−11 1/8 (1197) 3−7 (1092) 2.19 (0.20) 2.79 (0.26) 4.13 (0.38) 5.33 (0.49) 5.92 (0.55) 6.52E (0.61)54 4−5 1/8 (1349) 4−1 (1245) 2.50 (0.23) 3.18 (0.30) 4.71 (0.44) 6.07 (0.56) 6.75 (0.63) 7.43E (0.69)56 4−7 1/8 (1400) 4−3 (1295) 2.60 (0.24) 3.31 (0.31) 4.90 (0.46) 6.32 (0.59) 7.03 (0.65) 7.73E (0.72)60 4−11 1/8 (1502) 4−7 (1397) 2.80 (0.26) 3.57 (0.33) 5.28 (0.49) 6.81 (0.63) 7.58 (0.70) 8.34E (0.77)64 5−3 1/8 (1603) 4−11 (1499) 3.00 (0.28) 3.82 (0.36) 5.67 (0.53) 7.31 (0.68) 8.13 (0.75) 8.95E (0.83)72 5−11 1/8 (1807) 5−7 (1702) 3.41 (0.32) 4.34 (0.40) 6.43 (0.60) 8.30 (0.77) 9.23 (0.86) 10.16E (0.94)78 6−5 1/8 (1959) 6−1 (1854) 3.72 (0.35) 4.73 (0.44) 7.01 (0.65) 9.04 (0.84) 10.05 (0.93) 11.07E (1.03)84 6−11 1/8 (2111) 6−7 (2007) 4.02 (0.37) 5.12 (0.48) 7.58 (0.70) 9.78 (0.91) 10.88 (1.01) 11.98E (1.11)92 7−7 1/8 (2315) 7−3 (2210) 4.43 (0.41) 5.64 (0.52) 8.35 (0.78) 10.77 (1.00) 11.98 (1.11) 13.19E (1.23)96 7−11 1/8 (2416) 7−7 (2311) 4.63 (0.43) 5.90 (0.55) 8.74 (0.81) 11.27 (1.05) 12.53 (1.16) 13.80E (1.28)
CUPCAEgress OpeningMeasurements
Operating Casement
Width
CN 30 32 36 40
FS 2−6 (762) 2−8 (813) 3−0 (914) 3−4 (1016)
HeightClear
Opening 1−11 13/16 (605) 2−1 13/16 (656) 2−5 13/16 (757) 2−9 13/16 (859)
CN FSClear
Opening Square Feet (Square Meters)16 1−3 1/8 (384) 0−11 (279) 1.83 (0.17) 1.98 (0.18) 2.29 (0.21) 2.60 (0.24)18 1−5 1/8 (435) 1−1 (330) 2.16 (0.20) 2.34 (0.22) 2.70 (0.25) 3.06 (0.28)20 1−7 1/8 (486) 1−3 (381) 2.49 (0.23) 2.70 (0.25) 3.12 (0.29) 3.53 (0.33)24 1−11 1/8 (587) 1−7 (483) 3.15 (0.29) 3.42 (0.31) 3.94 (0.37) 4.47 (0.42)28 2−3 1/8 (689) 1−11 (584) 3.81 (0.35) 4.13 (0.38) 4.77 (0.44) 5.41 (0.50)32 2−7 1/8 (791) 2−3 (686) 4.47 (0.42) 4.85 (0.45) 5.60 (0.52) 6.35E (0.59)36 2−11 1/8 (892) 2−7 (787) 5.14 (0.48) 5.57 (0.52) 6.43E (0.60) 7.29E (0.68)40 3−3 1/8 (994) 2−11 (889) 5.80E (0.54) 6.28E (0.58) 7.26E (0.67) 8.23E (0.76)44 3−7 1/8 (1095) 3−3 (991) 6.46E (0.60) 7.00E (0.65) 8.09E (0.75) 9.17E (0.85)48 3−11 1/8 (1197) 3−7 (1092) 7.12E (0.66) 7.72E (0.72) 8.91E (0.83) 10.11E (0.94)54 4−5 1/8 (1349) 4−1 (1245) 8.11E (0.75) 8.79E (0.82) 10.16E (0.94) 11.52E (1.07)56 4−7 1/8 (1400) 4−3 (1295) 8.44E (0.78) 9.15E (0.85) 10.57E (0.98) 11.99E (1.11)60 4−11 1/8 (1502) 4−7 (1397) 9.10E (0.85) 9.87E (0.92) 11.40E (1.06) 12.93E (1.20)64 5−3 1/8 (1603) 4−11 (1499) 9.77E (0.91) 10.59E (0.98) 12.23E (1.14) 13.87E (1.29)72 5−11 1/8 (1807) 5−7 (1702) 11.09E (1.03) 12.02E (1.12) 13.88E (1.29) 15.75E (1.46)78 6−5 1/8 (1959) 6−1 (1854) 12.08E (1.12) 13.10E (1.22) 15.13E (1.41) 17.15E (1.59)84 6−11 1/8 (2111) 6−7 (2007) 13.07E (1.21) 14.17E (1.32) 16.37E (1.52) 18.56E (1.72)92 7−7 1/8 (2315) 7−3 (2210) 14.40E (1.34) 15.61E (1.45) 18.02E (1.67) 20.44E (1.90)96 7−11 1/8 (2416) 7−7 (2311) 15.06E (1.40) 16.32E (1.52) 18.85E (1.75) N/A
NOTE: “E” indicates a window that meets the requirements for Egress.Please note that the top of the sill must be no more than 44″ from the floor.
NOTE: The clear opening width may change when using retractable screen. Please contact your Marvin Representative.
CLAD ULTIMATE PUSH OUT CASEMENT
EGRESS OPENING MEASUREMENTS
1A.711708324
Marvin Architectural Detail Manual2011−08−24
CUPCAVent OpeningMeasurements
Operating Casement
Width
CN 16 18 20 24 26 28
FS 1−4 (406) 1−6 (457) 1−8 (508) 2−0 (610) 2−2 (660) 2−4 (711)
HeightVent
Opening 1−0 7/8 (327) 1−2 7/8 (378) 1−4 7/8 (429) 1−8 7/8 (530) 1−10 7/8 (289) 2−0 7/8 (632)
CN FSVent
Opening Square Feet (Square Meters)16 1−3 1/8 (384) 0−11 (279) 0.99 (0.09) 1.14 (0.11) 1.29 (0.12) 1.60 (0.15) 1.76 (0.16) 1.91 (0.18)18 1−5 1/8 (435) 1−1 (330) 1.17 (0.11) 1.35 (0.13) 1.53 (0.14) 1.89 (0.18) 2.07 (0.19) 2.25 (0.21)20 1−7 1/8 (486) 1−3 (381) 1.35 (0.13) 1.55 (0.14) 1.76 (0.16) 2.18 (0.21) 2.39 (0.22) 2.60 (0.24)24 1−11 1/8 (587) 1−7 (483) 1.70 (0.16) 1.97 (0.18) 2.23 (0.21) 2.76 (0.26) 3.03 (0.28) 3.29 (0.31)28 2−3 1/8 (689) 1−11 (584) 2.06 (0.19) 2.38 (0.22) 2.70 (0.25) 3.34 (0.31) 3.66 (0.34) 3.98 (0.37)32 2−7 1/8 (791) 2−3 (686) 2.42 (0.22) 2.79 (0.26) 3.17 (0.29) 3.92 (0.36) 4.30 (0.40) 4.67 (0.43)36 2−11 1/8 (892) 2−7 (787) 2.78 (0.26) 3.21 (0.30) 3.64 (0.34) 4.50 (0.42) 4.93 (0.46) 5.36 (0.50)40 3−3 1/8 (994) 2−11 (889) 3.13 (0.29) 3.62 (0.34) 4.11 (0.38) 5.08 (0.47) 5.57 (0.52) 6.05 (0.56)44 3−7 1/8 (1095) 3−3 (991) 3.49 (0.32) 4.03 (0.37) 4.58 (0.43) 5.66 (0.53) 6.20 (0.58) 6.75 (0.63)48 3−11 1/8 (1197) 3−7 (1092) 3.85 (0.36) 4.45 (0.41) 5.04 (0.47) 6.24 (0.58) 6.84 (0.64) 7.44 (0.69)54 4−5 1/8 (1349) 4−1 (1245) 4.39 (0.41) 5.07 (0.47) 5.75 (0.53) 7.11 (0.66) 7.79 (0.72) 8.47 (0.79)56 4−7 1/8 (1400) 4−3 (1295) 4.56 (0.42) 5.27 (0.49) 5.98 (0.56) 7.40 (0.69) 8.11 (0.75) 8.82 (0.82)60 4−11 1/8 (1502) 4−7 (1397) 4.92 (0.46) 5.69 (0.53) 6.45 (0.60) 7.98 (0.74) 8.74 (0.81) 9.51 (0.88)64 5−3 1/8 (1603) 4−11 (1499) 5.28 (0.49) 6.10 (0.57) 6.92 (0.64) 8.56 (0.80) 9.38 (0.87) 10.20 (0.95)72 5−11 1/8 (1807) 5−7 (1702) 5.99 (0.56) 6.93 (0.64) 7.86 (0.73) 9.72 (0.90) 10.65 (0.99) 11.58 (1.08)78 6−5 1/8 (1959) 6−1 (1854) 6.53 (0.61) 7.55 (0.70) 8.56 (0.80) 10.59 (0.98) 11.60 (1.08) 12.62 (1.17)84 6−11 1/8 (2111) 6−7 (2007) 7.07 (0.66) 8.17 (0.76) 9.26 (0.86) 11.46 (1.06) 12.56 (1.17) 13.65 (1.27)92 7−7 1/8 (2315) 7−3 (2210) 7.78 (0.72) 8.99 (0.84) 10.20 (0.95) 12.62 (1.17) 13.83 (1.28) 15.04 (1.40)96 7−11 1/8 (2416) 7−7 (2311) 8.14 (0.76) 9.40 (0.87) 10.67 (0.99) 13.20 (1.23) 14.46 (1.34) 15.73 (1.46)
CUPCAVent OpeningMeasurements
Operating Casement
Width
CN 30 32 36 40
FS 2−6 (762) 2−8 (813) 3−0 (914) 3−4 (1016)
HeightVent
Opening 2−2 7/8 (683) 2−4 7/8 (733) 2−8 7/8 (835) 3−0 7/8 (937)
CN FSVent
Opening Square Feet (Square Meters)16 1−3 1/8 (384) 0−11 (279) 2.06 (0.19) 2.22 (0.21) 2.52 (0.23) 2.83 (0.26)18 1−5 1/8 (435) 1−1 (330) 2.44 (0.23) 2.62 (0.24) 2.98 (0.28) 3.34 (0.31)20 1−7 1/8 (486) 1−3 (381) 2.81 (0.26) 3.02 (0.28) 3.44 (0.32) 3.85 (0.36)24 1−11 1/8 (587) 1−7 (483) 3.56 (0.33) 3.82 (0.35) 4.35 (0.40) 4.88 (0.45)28 2−3 1/8 (689) 1−11 (584) 4.30 (0.40) 4.62 (0.43) 5.26 (0.49) 5.90 (0.55)32 2−7 1/8 (791) 2−3 (686) 5.05 (0.47) 5.42 (0.50) 6.18 (0.57) 6.93 (0.64)36 2−11 1/8 (892) 2−7 (787) 5.79 (0.54) 6.23 (0.58) 7.09 (0.66) 7.95 (0.74)40 3−3 1/8 (994) 2−11 (889) 6.54 (0.61) 7.03 (0.65) 8.00 (0.74) 8.98 (0.83)44 3−7 1/8 (1095) 3−3 (991) 7.29 (0.68) 7.83 (0.73) 8.92 (0.83) 10.00 (0.93)48 3−11 1/8 (1197) 3−7 (1092) 8.03 (0.75) 8.63 (0.80) 9.83 (0.91) 11.02 (1.02)54 4−5 1/8 (1349) 4−1 (1245) 9.15 (0.85) 9.84 (0.91) 11.20 (1.04) 12.56 (1.17)56 4−7 1/8 (1400) 4−3 (1295) 9.53 (0.89) 10.24 (0.95) 11.65 (1.08) 13.07 (1.21)60 4−11 1/8 (1502) 4−7 (1397) 10.27 (0.95) 11.04 (1.03) 12.57 (1.17) 14.10 (1.31)64 5−3 1/8 (1603) 4−11 (1499) 11.02 (1.02) 11.84 (1.10) 13.48 (1.25) 15.12 (1.40)72 5−11 1/8 (1807) 5−7 (1702) 12.51 (1.16) 13.44 (1.25) 15.31 (1.42) 17.17 (1.60)78 6−5 1/8 (1959) 6−1 (1854) 13.63 (1.27) 14.65 (1.36) 16.68 (1.55) 18.71 (1.74)84 6−11 1/8 (2111) 6−7 (2007) 14.75 (1.37) 15.85 (1.47) 18.05 (1.68) 20.24 (1.88)92 7−7 1/8 (2315) 7−3 (2210) 16.25 (1.51) 17.45 (1.62) 19.87 (1.85) 22.29 (2.07)96 7−11 1/8 (2416) 7−7 (2311) 16.99 (1.58) 18.26 (1.70) 20.79 (1.93) N/A
CLAD ULTIMATE PUSH OUT CASEMENT
VENT OPENING MEASUREMENTS
1A.811708324
Marvin Architectural Detail Manual2011−08−24
CUPCADaylight Measurement
Width
CN 16 18 20 24 26 28
FS 1−4 (406) 1−6 (457) 1−8 (508) 2−0 (610) 2−2 (660) 2−4 (711)
Height DLO 10 3/16 (259) 1−0 3/16 (310) 1−2 3/16 (360) 1−6 3/16 (462) 1−8 3/16 (513) 1−10 3/16 (564)
CNFS
HeightDLO
Height Square Feet (Square Meters)
16 1−3 1/8 (384) 0−9 5/16 (237) 0.66 (0.06) 0.79 (0.07) 0.92 (0.09) 1.18 (0.11) 1.31 (0.12) 1.43 (0.13)
18 1−5 1/8 (435) 0−11 5/16 (287) 0.80 (0.07) 0.96 (0.09) 1.11 (0.10) 1.43 (0.13) 1.59 (0.15) 1.74 (0.16)
20 1−7 1/8 (486) 1−1 5/16 (338) 0.94 (0.09) 1.13 (0.10) 1.31 (0.12) 1.68 (0.16) 1.87 (0.17) 2.05 (0.19)
24 1−11 1/8 (587) 1−5 5/16 (440) 1.22 (0.11) 1.47 (0.14) 1.71 (0.16) 2.19 (0.20) 2.43 (0.23) 2.67 (0.25)
28 2−3 1/8 (689) 1−9 5/16 (541) 1.51 (0.14) 1.80 (0.17) 2.10 (0.20) 2.69 (0.25) 2.99 (0.28) 3.28 (0.31)
32 2−7 1/8 (791) 2−1 5/16 (643) 1.79 (0.17) 2.14 (0.20) 2.49 (0.23) 3.20 (0.30) 3.55 (0.33) 3.90 (0.36)
36 2−11 1/8 (892) 2−5 5/16 (745) 2.07 (0.19) 2.48 (0.23) 2.89 (0.27) 3.70 (0.34) 4.11 (0.38) 4.52 (0.42)
40 3−3 1/8 (994) 2−9 5/16 (846) 2.36 (0.22) 2.82 (0.26) 3.28 (0.30) 4.21 (0.39) 4.67 (0.43) 5.13 (0.48)
44 3−7 1/8 (1095) 3−1 5/16 (948) 2.64 (0.25) 3.16 (0.29) 3.68 (0.34) 4.71 (0.44) 5.23 (0.49) 5.75 (0.53)
48 3−11 1/8 (1197) 3−5 5/16 (1049) 2.92 (0.27) 3.50 (0.32) 4.07 (0.38) 5.22 (0.48) 5.79 (0.54) 6.37 (0.59)
54 4−5 1/8 (1349) 3−11 5/16 (1202) 3.35 (0.31) 4.00 (0.37) 4.66 (0.43) 5.98 (0.56) 6.63 (0.62) 7.29 (0.68)
56 4−7 1/8 (1400) 4−1 5/16 (1253) 3.49 (0.32) 4.17 (0.39) 4.86 (0.45) 6.23 (0.58) 6.91 (0.64) 7.60 (0.71)
60 4−11 1/8 (1502) 4−5 5/16 (1354) 3.77 (0.35) 4.51 (0.42) 5.25 (0.49) 6.73 (0.63) 7.47 (0.69) 8.21 (0.76)
64 5−3 1/8 (1603) 4−9 5/16 (1456) 4.05 (0.38) 4.85 (0.45) 5.65 (0.52) 7.24 (0.67) 8.03 (0.75) 8.83 (0.82)
72 5−11 1/8 (1807) 5−5 5/16 (1659) 4.62 (0.43) 5.53 (0.51) 6.43 (0.60) 8.25 (0.78) 9.16 (0.85) 10.06 (0.93)
78 6−5 1/8 (1959) 5−11 5/16 (1811) 5.04 (0.47) 6.04 (0.56) 7.03 (0.65) 9.01 (0.84) 10.00 (0.93) 10.99 (1.02)
84 6−11 1/8 (2111) 6−5 5/16 (1964) 5.47 (0.51) 6.54 (0.61) 7.62 (0.71) 9.76 (0.91) 10.84 (1.01) 11.91 (1.11)
92 7−7 1/8 (2315) 7−1 5/16 (2167) 6.04 (0.56) 7.22 (0.67) 8.41 (0.78) 10.77 (1.00) 11.96 (1.11) 13.14 (1.22)
96 7−11 1/8 (2416) 7−5 5/16 (2269) 6.32 (0.59) 7.56 (0.70) 8.80 (0.82) 11.28 (1.05) 12.52 (1.16) 13.76 (1.28)
CUPCADaylight Measurement
WidthCN 30 32 36 40FS 2−6 (762) 2−8 (813) 3−0 (914) 3−4 (1016)
Height DLO 2−0 3/16 (614) 2−2 3/16 (665) 2−6 3/16 (767) 2−10 3/16 (868)
CNFS
HeightDLO
Height Square Feet (Square Meters)16 1−3 1/8 (384) 0−9 5/16 (237) 1.56 (0.15) 1.69 (0.16) 1.95 (0.18) 2.21 (0.21)18 1−5 1/8 (435) 0−11 5/16 (287) 1.90 (0.18) 2.06 (0.19) 2.37 (0.22) 2.69 (0.25)20 1−7 1/8 (486) 1−1 5/16 (338) 2.24 (0.21) 2.42 (0.21) 2.79 (0.26) 3.16 (0.29)24 1−11 1/8 (587) 1−5 5/16 (440) 2.91 (0.27) 3.15 (0.29) 3.63 (0.34) 4.11 (0.38)28 2−3 1/8 (689) 1−9 5/16 (541) 3.58 (0.33) 3.88 (0.36) 4.47 (0.42) 5.06 (0.47)32 2−7 1/8 (791) 2−1 5/16 (643) 4.25 (0.40) 4.60 (0.43) 5.31 (0.49) 6.01 (0.56)36 2−11 1/8 (892) 2−5 5/16 (745) 4.92 (0.46) 5.33 (0.50) 6.14 (0.57) 6.96 (0.65)40 3−3 1/8 (994) 2−9 5/16 (846) 5.60 (0.52) 6.06 (0.56) 6.98 (0.65) 7.91 (0.73)44 3−7 1/8 (1095) 3−1 5/16 (948) 6.27 (0.58) 6.79 (0.63) 7.82 (0.73) 8.86 (0.82)48 3−11 1/8 (1197) 3−5 5/16 (1049) 6.94 (0.64) 7.51 (0.70) 8.66 (0.81) 9.81 (0.91)54 4−5 1/8 (1349) 3−11 5/16 (1202) 7.95 (0.74) 8.60 (0.80) 9.92 (0.92) 11.23 (1.04)56 4−7 1/8 (1400) 4−1 5/16 (1253) 8.28 (0.77) 8.97 (0.83) 10.34 (0.96) 11.71 (1.09)60 4−11 1/8 (1502) 4−5 5/16 (1354) 8.96 (0.83) 9.70 (0.90) 11.18 (1.04) 12.66 (1.18)64 5−3 1/8 (1603) 4−9 5/16 (1456) 9.63 (0.89) 10.42 (0.97) 12.01 (1.12) 13.61 (1.26)72 5−11 1/8 (1807) 5−5 5/16 (1659) 10.97 (1.02) 11.88 (1.10) 13.69 (1.27) 15.51 (1.44)78 6−5 1/8 (1959) 5−11 5/16 (1811) 11.98 (1.11) 12.97 (1.21) 14.95 (1.39) 16.93 (1.57)84 6−11 1/8 (2111) 6−5 5/16 (1964) 12.99 (1.21) 14.06 (1.31) 16.21 (1.51) 18.35 (1.71)92 7−7 1/8 (2315) 7−1 5/16 (2167) 14.33 (1.33) 15.51 (1.44) 17.88 (1.66) 20.25 (1.88)
96 7−11 1/8 (2416) 7−5 5/16 (2269) 15.00 (1.39) 16.24 (1.51) 18.72 (1.74) N/A
NOTE: Standard bottom rail
CLAD ULTIMATE PUSH OUT CASEMENT
DAYLIGHT OPENING MEASUREMENTS
1A.911708324
Marvin Architectural Detail Manual2011−02−28
Clad Ultimate Casement Picture Units
Daylight Opening
Width
CN 40 48 56 60 64
RO 3−5 (1041) 4−1 (1245) 4−9 (1448) 5−1 (1549) 5−5 (1651)
FS 3−4 (1016) 4−0 (1219) 4−8 (1422) 5−0 (1524) 5−4 (1626)
Height DLO 2−10 3/16 (868) 3−6 3/16 (1072) 4−2 3/16 (1275) 4−6 3/16 (1376) 4−10 3/16 (1478)
CN RO FS DLO Square Feet (Square Meters)
12 11 5/8 (295) 11 1/8 (283) 5 5/16 (135) 1.26 (0.12) 1.56 (0.14) 1.85 (0.17) 2.00 (0.19) 2.15 (0.20)
14 1−1 5/8 (346) 1−1 1/8 (333) 7 5/16 (186) 1.74 (0.16) 2.14 (0.20) 2.55 (0.24) 2.75 (0.26) 2.95 (0.27)
16 1−3 5/8 (397) 1−3 1/8 (384) 9 5/16 (237) 2.21 (0.21) 2.73 (0.25) 3.25 (0.30) 3.50 (0.33) 3.76 (0.35)
18 1−5 5/8 (448) 1−5 1/8 (435) 11 5/16 (287) 2.69 (0.25) 3.31 (0.31) 3.94 (0.37) 4.26 (0.40) 4.57 (0.42)
20 1−7 5/8 (498) 1−7 1/8 (486) 1−1 5/16 (338) 3.16 (0.29) 3.90 (0.36) 4.64 (0.43) 5.01 (0.47) 5.38 (0.50)
24 1−11 5/8 (600) 1−11 1/8 (587) 1−5 5/16 (440) 4.11 (0.38) 5.07 (0.47) 6.03 (0.56) 6.51 (0.60) 7.00 (0.65)
28 2−3 5/8 (702) 2−3 1/8 (689) 1−9 5/16 (541) 5.06 (0.47) 6.24 (0.58) 7.43 (0.69) 8.02 (0.75) 8.61 (0.80)
32 2−7 5/8 (803) 2−7 1/8 (791) 2−1 5/16 (643) 6.01 (0.56) 7.42 (0.69) 8.82 (0.82) 9.52 (0.88) 10.23 (0.95)
36 2−11 5/8 (905) 2−11 1/8 (892) 2−5 5/16 (745) 6.96 (0.65) 8.59 (0.80) 10.22 (0.95) 11.03 (1.02) 11.84 (1.10)
40 3−3 5/8 (1006) 3−3 1/8 (994) 2−9 5/16 (846) 7.91 (0.73) 9.76 (0.91) 11.61 (1.08) 12.54 (1.17) 13.46 (1.25)
44 3−7 5/8 (1108) 3−7 1/8 (1095) 3−1 5/16 (948) 8.86 (0.82) 10.93 (1.02) 13.00 (1.21) 14.04 (1.30) 15.08 (1.40)
48 3−11 5/8 (1210) 3−11 1/8 (1197) 3−5 5/16 (1049) 9.81 (0.91) 12.10 (1.12) 14.40 (1.34) 15.55 (1.44) 16.69 (1.55)
54 4−3 5/8 (1362) 4−3 1/8 (1349) 3−11 5/16 (1202) 11.23 (1.04) 13.86 (1.29) 16.49 (1.53) 17.80 (1.65) 19.12 (1.78)
56 4−5 5/8 (1413) 4−5 1/8 (1400) 4−1 5/16 (1253) 11.71 (1.09) 14.45 (1.34) 17.19 (1.60) 18.56 (1.72) 19.93 (1.85)
60 4−11 5/8 (1514) 4−11 1/8 (1502) 4−5 5/16 (1354) 12.66 (1.18) 15.62 (1.45) 18.58 (1.73) 20.06 (1.86) 21.54 (2.00)
64 5−3 5/8 (1616) 5−3 1/8 (1603) 4−9 5/16 (1456) 13.61 (1.26) 16.79 (1.56) 19.97 (1.86) 21.57 (2.00) 23.16 (2.15)
72 5−11 5/8 (1819) 5−11 1/8 (1807) 5−5 5/16 (1659) 15.51 (1.44) 19.14 (1.78) 22.76 (2.11) 24.58 (2.28) 26.39 (2.45)
78 6−5 5/8 (1972) 6−5 1/8 (1959) 5−11 5/16 (1811) 16.93 (1.57) 20.89 (1.94) 24.85 (2.31) 26.83 (2.49) 28.82 (2.68)
84 6−11 5/8 (2124) 6−11 1/8 (2061) 6−5 5/16 (1964) 18.36 (1.71) 22.65 (2.10) 26.94 (2.50) 29.09 (2.70) 31.24 (2.90)
92 7−7 5/8 (2327) 7−7 1/8 (2315) 7−1 5/16 (2167) 20.26 (1.88) 24.99 (2.32) 29.73 (2.76) 32.10 (2.98) 34.47 (3.20)
96 7−11 5/8 (2429) 7−11 1/8 (2416) 7−5 5/16 (2269) 21.20 (1.97) 26.17 (2.43) 31.13 (2.89) 33.61 (3.12) 36.09 (3.35)
CLAD ULTIMATE CASEMENT PICTURE
Daylight Opening Measurements CUCAP and CUPCAP
1A.1011708324
Marvin Architectural Detail Manual2011−02−28
Clad Ultimate Casement/ Picture Units
Daylight Opening
Width
CN 72 80 88 96
RO 6−0 (1854) 6−9 (2057) 7−5 (2261) 8−1 (2464)
FS 6−0 (1829) 6−8 (2032) 7−4 (2235) 8−0 (2438)
Height DLO 5−6 3/16 (1681) 6−2 3/16 (1884) 6−10 3/16 (2088) 7−6 3/16 (2291)
CN RO FS DLO Square Feet (Square Meters)
12 11 5/8 (295) 11 1/8 (283) 5 5/16 (135) 2.44 (0.23) 2.74 (0.25) 3.03 (0.28) 3.33 (0.31)
14 1−1 5/8 (346) 1−1 1/8 (333) 7 5/16 (186) 3.36 (0.31) 3.77 (0.35) 4.17 (0.39) 4.58 (0.43)
16 1−3 5/8 (397) 1−3 1/8 (384) 9 5/16 (237) 4.28 (0.40) 4.80 (0.45) 5.31 (0.49) 5.83 (0.54)
18 1−5 5/8 (448) 1−5 1/8 (435) 11 5/16 (287) 5.20 (0.48) 5.83 (0.54) 6.46 (0.60) 7.08 (0.66)
20 1−7 5/8 (498) 1−7 1/8 (486) 1−1 5/16 (338) 6.12 (0.57) 6.86 (0.64) 7.60 (0.71) 8.34 (0.77)
24 1−11 5/8 (600) 1−11 1/8 (587) 1−5 5/16 (440) 7.96 (0.74) 8.92 (0.83) 9.88 (0.92) 10.84 (1.01)
28 2−3 5/8 (702) 2−3 1/8 (689) 1−9 5/16 (541) 9.80 (0.91) 10.98 (1.02) 12.16 (1.13) 13.35 (1.24)
32 2−7 5/8 (803) 2−7 1/8 (791) 2−1 5/16 (643) 11.63 (1.08) 13.04 (1.21) 14.45 (1.34) 15.85 (1.47)
36 2−11 5/8 (905) 2−11 1/8 (892) 2−5 5/16 (745) 13.47 (1.25) 15.10 (1.40) 16.73 (1.55) 18.36 (1.71)
40 3−3 5/8 (1006) 3−3 1/8 (994) 2−9 5/16 (846) 15.31 (1.42) 17.16 (1.59) 19.01 (1.77) 20.86 (1.94)
44 3−7 5/8 (1108) 3−7 1/8 (1095) 3−1 5/16 (948) 17.15 (1.59) 19.22 (1.79) 21.30 (1.98) 23.37 (2.17)
48 3−11 5/8 (1210) 3−11 1/8 (1197) 3−5 5/16 (1049) 18.99 (1.76) 21.28 (1.98) 23.58 (2.19) 25.87 (2.40)
54 4−3 5/8 (1362) 4−3 1/8 (1349) 3−11 5/16 (1202) 21.75 (2.02) 24.37 (2.26) 27.00 (2.51) 29.63 (2.75)
56 4−5 5/8 (1413) 4−5 1/8 (1400) 4−1 5/16 (1253) 22.67 (2.11) 25.40 (2.36) 28.14 (2.61) 30.88 (2.87)
60 4−11 5/8 (1514) 4−11 1/8 (1502) 4−5 5/16 (1354) 24.50 (2.28) 27.43 (2.55) 30.43 (2.83) 33.39 (3.10)
64 5−3 5/8 (2378) 5−3 1/8 (1603) 4−9 5/16 (1456) 26.34 (2.45) 29.53 (2.74) 32.71 (3.04) 35.89 (3.33)
72 5−11 5/8 (1819) 5−11 1/8 (1807) 5−5 5/16 (1659) 30.02 (2.79) 33.65 (3.13) 37.28 (3.46) 40.90 (3.80)
78 6−5 5/8 (1972) 6−5 1/8 (1959) 5−11 5/16 (1811) 32.78 (3.05) 36.74 (3.41) 40.70 (3.78) 44.66 (4.15)
84 6−11 5/8 (2124) 6−11 1/8 (2061) 6−5 5/16 (1964) 35.54 (3.30) 39.83 (3.70) 44.13 (4.10) 48.42 (4.50)
92 7−7 5/8 (2327) 7−7 1/8 (2315) 7−1 5/16 (2167) 39.21 (3.64) 43.95 (4.08) 48.69 (4.52) N/A
96 7−11 5/8 (2429) 7−11 1/8 (2416) 7−5 5/16 (2269) 41.05 (3.81) 46.01 (4.27) 50.97 (4.74) N/A
CLAD ULTIMATE CASEMENT PICTURE
Daylight Opening Measurements CUCAP and CUPCAP
1A.1111708324
Marvin Architectural Detail Manual2011−04−25
Most Common NFRC Thermal Performance ValuesClad Ultimate Casement Operator
Size Tested Frame OM 24 x 59
Energy Data UValue
SolarHeat Gain
Coeffi-cient
Visible LightTransmittance Condensation
ResistanceU.S.
Energy Star3/4″ IG − Air 0.44 0.53 0.56 43 −3/4″ IG / LoĒ2 272® − Air 0.33 0.29 0.49 55 SC3/4″ IG / LoĒ2 272® − Argon 0.30 0.29 0.49 58 N, NC, SC3/4″ IG / LoĒ2 272® − Air SDLS < 1″ 0.33 0.26 0.44 55 SC, S3/4″ IG / LoĒ2 272® − Air SDLS > 1″ 0.33 0.24 0.40 55 SC, S3/4″ IG / LoĒ2 272® − Air SDLN < 1″ 0.33 0.26 0.44 55 SC, S3/4″ IG / LoĒ2 272® − Air SDLN > 1″ 0.33 0.24 0.40 55 SC, S3/4″ IG / LoĒ2 272® − Argon SDLS < 1″ 0.30 0.26 0.44 58 N, NC, SC, S3/4″ IG / LoĒ2 272® − Argon SDLS > 1″ 0.30 0.24 0.40 58 N, NC, SC, S3/4″ IG / LoĒ2 272® − Argon SDLN < 1″ 0.30 0.26 0.44 58 N, NC, SC, S3/4″ IG − LoĒ2 272® − Argon SDLN > 1″ 0.30 0.24 0.40 58 N, NC, SC, S3/4″ IG − LoĒ2 272® − Air − GBG 0.33 0.26 0.44 55 SC, S3/4″ IG − LoĒ2 272® − Argon − GBG 0.30 0.26 0.44 58 N, NC, SC, S3/4″ IG − LoĒ3 366® − Air 0.32 0.19 0.44 55 NC, SC, S3/4″ IG − LoĒ3 366® − Argon 0.29 0.19 0.44 59 N, NC, SC, S3/4″ IG − LoĒ3 366® − Air SDLS < 1″ 0.33 0.18 0.40 55 SC, S3/4″ IG − LoĒ3 366® − Air SDLS > 1″ 0.33 0.16 0.36 55 SC, S3/4″ IG − LoĒ3 366® − Air SDLN < 1″ 0.32 0.18 0.40 55 NC, SC, S3/4″ IG − LoĒ3 366® − Air SDLN > 1″ 0.32 0.16 0.36 55 NC, SC, S3/4″ IG − LoĒ3 366® − Argon SDLS < 1″ 0.30 0.18 0.40 59 N, NC, SC, S3/4″ IG − LoĒ3 366® − Argon SDLS > 1″ 0.30 0.16 0.36 59 N, NC, SC, S3/4″ IG − LoĒ3 366® − Argon SDLN < 1″ 0.29 0.18 0.40 59 N, NC, SC, S3/4″ IG − LoĒ3 366® − Argon SDLN > 1″ 0.29 0.16 0.36 59 N, NC, SC, S3/4″ IG − LoĒ3 366® − GBG 0.32 0.18 0.40 55 NC, SC, S3/4″ IG − LoĒ3 366® − Argon, GBG 0.29 0.18 0.40 59 N, NC, SC, S1″ IG − Tri−pane LoĒ 180� Argon LoĒ 180� 0.25 0.39 0.47 65 N, NC1″ IG − Tri−pane LoĒ 180� Argon LoĒ 180� SDLN < 1″ 0.25 0.36 0.43 65 N, NC1″ IG − Tri−pane LoĒ 180� Argon LoĒ 180� SDLN > 1″ 0.25 0.32 0.38 65 N, NC1″ IG − Tri−pane LoĒ 180� Krypton/Argon LoĒ 180� 0.23 0.39 0.47 67 N, NC1″ IG − Tri−pane LoĒ 180� Krypton/Argon LoĒ 180� SDLN < 1″ 0.23 0.36 0.43 67 N, NC1″ IG − Tri−pane LoĒ 180� Krypton/Argon LoĒ 180� SDLN > 1″ 0.23 0.32 0.38 67 N, NC1″ IG − Tri−pane LoĒ2 272® Argon LoĒ2 272® 0.23 0.24 0.39 66 N, NC, SC, S1″ IG − Tri−pane LoĒ2 272® Argon LoĒ2 272® SDLN < 1″ 0.23 0.22 0.35 66 N, NC, SC, S1″ IG − Tri−pane LoĒ2 272® Argon LoĒ2 272® SDLN > 1″ 0.23 0.20 0.32 66 N, NC, SC, S1″ IG − Tri−pane LoĒ2 272® Krypton/Argon LoĒ2 272® 0.21 0.24 0.39 69 N, NC, SC, S1″ IG − Tri−pane LoĒ2 272® Krypton/Argon LoĒ2 272® SDLN < 1″ .021 0.22 0.35 69 N, NC, SC, S1″ IG − Tri−pane LoĒ2 272® Krypton/Argon LoĒ2 272® SDLN > 1″ 0.21 0.20 0.32 69 N, NC, SC, S
NOTE: >1″ and <1″ are referring to the overall bar size.Product Values are determined using the National Fenestration Rating Council (NFRC) Procedures for determining fenestration product values.U−Value: (Btu/hr−sq ft−*F) Lower the U−Value, the greater the resistance to heat flow and better its insulating value.R−Value: (1/U−Value) Higher the R−Value, the greater the resistance to heat flow and better its insulating value.Solar Heat Gain Coefficient (SHGC): The lower a window’s SHGC, the less solar heat it transmits, and the greater its shading ability.Visible Light Transmittance (VLT): Percentage of visible light transmitted through the unit.Condensation Resistance (CR): Condensation Resistance measures the ability of a product to resist the formation of condensation on the interiorsurface of a product.The higher the CR rating, the better that product is at resisting condensation formation.Capillary tubes are required for IG units at high elevations. Argon will not be furnished in units with capillary tubes.Values listed are common glazing options, call 800−346−3363 for additional NFRC unit values.
CLAD ULTIMATE CASEMENT
NFRC THERMAL PERFORMANCE
1A.1211708324
Marvin Architectural Detail Manual2011−04−25
Most Common NFRC Thermal Performance ValuesClad Ultimate Push Out Casement Operator
Size Tested Frame OM 24 x 59
Energy Data UValue
Solar HeatGain
Coefficient
Visible LightTransmittance Condensation
ResistanceU.S.
Energy Star3/4″ IG − Air 0.45 0.53 0.56 44 −3/4″ IG / LoĒ2 272® − Air 0.34 0.29 0.49 56 SC3/4″ IG / LoĒ2 272® − Argon 0.31 0.29 0.49 59 NC, SC3/4″ IG / LoĒ2 272® − Air SDLS < 1″ 0.35 0.26 0.44 56 SC, S3/4″ IG / LoĒ2 272® − Air SDLS > 1″ 0.34 0.24 0.40 56 SC, S3/4″ IG / LoĒ2 272® − Air SDLN < 1″ 0.34 0.26 0.44 56 SC, S3/4″ IG / LoĒ2 272® − Air SDLN > 1″ 0.34 0.24 0.40 56 SC, S3/4″ IG / LoĒ2 272® − Argon SDLS < 1″ 0.31 0.26 0.44 59 NC, SC, S3/4″ IG / LoĒ2 272® − Argon SDLS > 1″ 0.31 0.24 0.40 59 NC, SC, S3/4″ IG / LoĒ2 272® − Argon SDLN < 1″ 0.31 0.26 0.44 59 NC, SC, S3/4″ IG − LoĒ2 272® − Argon SDLN > 1″ 0.31 0.24 0.40 59 NC, SC, S3/4″ IG − LoĒ2 272® − Air − GBG 0.34 0.26 0.44 56 SC, S3/4″ IG − LoĒ2 272® − Argon − GBG 0.31 0.26 0.40 59 NC, SC, S3/4″ IG − LoĒ3 366® − Air 0.33 0.19 0.44 56 SC, S3/4″ IG − LoĒ3 366® − Argon 0.30 0.19 0.44 59 N, NC, SC, S3/4″ IG − LoĒ3 366® − Air SDLS < 1″ 0.34 0.18 0.40 56 SC, S3/4″ IG − LoĒ3 366® − Air SDLS > 1″ 0.34 0.16 0.36 56 SC, S3/4″ IG − LoĒ3 366® − Air SDLN < 1″ 0.33 0.18 0.40 56 SC, S3/4″ IG − LoĒ3 366® − Air SDLN > 1″ 0.33 0.16 0.36 56 SC, S3/4″ IG − LoĒ3 366® − Argon SDLS < 1″ 0.31 0.18 0.40 59 NC, SC, S3/4″ IG − LoĒ3 366® − Argon SDLS > 1″ 0.31 0.16 0.36 59 NC, SC, S3/4″ IG − LoĒ3 366® − Argon SDLN < 1″ 0.30 0.18 0.40 59 N, NC, SC, S3/4″ IG − LoĒ3 366® − Argon SDLN > 1″ 0.30 0.16 0.36 59 N, NC, SC, S3/4″ IG − LoĒ3 366® − GBG 0.33 0.18 0.40 56 SC, S3/4″ IG − LoĒ3 366® − Argon, GBG 0.30 0.18 0.40 59 N, NC, SC, S1″ IG − Tri−pane LoĒ 180� Argon LoĒ 180� 0.26 0.39 0.47 66 N, NC1″ IG − Tri−pane LoĒ 180� Argon LoĒ 180� SDLN < 1″ 0.26 0.36 0.43 66 N, NC1″ IG − Tri−pane LoĒ 180� Argon LoĒ 180� SDLN > 1″ 0.26 0.32 0.38 66 N, NC1″ IG − Tri−pane LoĒ 180� Krypton/Argon LoĒ 180� 0.23 0.39 0.47 68 N, NC1″ IG − Tri−pane LoĒ 180� Krypton/Argon LoĒ 180� SDLN < 1″ 0.23 0.36 0.43 68 N, NC1″ IG − Tri−pane LoĒ 180� Krypton/Argon LoĒ 180� SDLN > 1″ 0.23 0.32 0.38 68 N, NC1″ IG − Tri−pane LoĒ2 272® Argon LoĒ2 272® 0.24 0.25 0.39 67 N, NC, SC, S1″ IG − Tri−pane LoĒ2 272® Argon LoĒ2 272® SDLN < 1″ 0.24 0.22 0.35 67 N, NC, SC, S1″ IG − Tri−pane LoĒ2 272® Argon LoĒ2 272® SDLN > 1″ 0.24 0.20 0.32 67 N, NC, SC, S1″ IG − Tri−pane LoĒ2 272® Krypton/Argon LoĒ2 272® 0.22 0.25 0.39 68 N, NC, SC, S1″ IG − Tri−pane LoĒ2 272® Krypton/Argon LoĒ2 272® SDLN < 1″ 0.22 0.22 0.35 68 N, NC, SC, S1″ IG − Tri−pane LoĒ2 272® Krypton/Argon LoĒ2 272® SDLN > 1″ 0.22 0.20 0.32 68 N, NC, SC, S
NOTE: >1″ and <1″ are referring to the overall bar size.Product Values are determined using the National Fenestration Rating Council (NFRC) Procedures for determining fenestration product values.U−Value: (Btu/hr−sq ft−*F) Lower the U−Value, the greater the resistance to heat flow and better its insulating value.R−Value: (1/U−Value) Higher the R−Value, the greater the resistance to heat flow and better its insulating value.Solar Heat Gain Coefficient (SHGC): The lower a window’s SHGC, the less solar heat it transmits, and the greater its shading ability.Visible Light Transmittance (VLT): Percentage of visible light transmitted through the unit.Condensation Resistance (CR): Condensation Resistance measures the ability of a product to resist the formation of condensation on the interiorsurface of a product.The higher the CR rating, the better that product is at resisting condensation formation.Capillary tubes are required for IG units at high elevations. Argon will not be furnished in units with capillary tubes.Values listed are common glazing options, call 800−346−3363 for additional NFRC unit values.
CLAD ULTIMATE PUSH OUT CASEMENT
NFRC THERMAL PERFORMANCE
1A.1311708324
Marvin Architectural Detail Manual2011−02−28
Most Common NFRC Thermal Performance ValuesClad Ultimate Casement Operator
Size Tested Frame OM 24 x 59 − 3/4� IG Impact Zone 3
Energy Data UValue
Solar HeatGain
Coefficient
Visible LightTransmittance Condensation
ResistanceU.S.
Energy Star3/4″ IG − Air Lami 0.46 0.49 0.55 41 −3/4″ IG − LoĒ2−272® − Air Lami 0.37 0.29 0.48 49 −3/4″ IG − LoĒ2−272® − Argon Lami 0.33 0.28 0.48 54 SC3/4″ IG − LoĒ2−272® − Air Lami − GBG 0.39 0.26 0.43 49 S3/4″ IG − LoĒ2−272® − Argon Lami − GBG 0.34 0.26 0.43 54 SC, S3/4″ IG − LoĒ2−272® − Air Lami SDLS < 1″ 0.38 0.26 0.43 49 S3/4″ IG − LoĒ2−272® − Air Lami SDLS > 1″ 0.38 0.24 0.39 49 S3/4″ IG − LoĒ2−272® − Air Lami SDLN < 1″ 0.37 0.26 0.43 49 S3/4″ IG − LoĒ2−272® − Air Lami SDLN > 1″ 0.37 0.24 0.39 49 S3/4″ IG − LoĒ2−272® − Argon Lami SDLS < 1″ 0.34 0.26 0.43 54 SC, S3/4″ IG − LoĒ2−272® − Argon Lami SDLS > 1″ 0.34 0.23 0.39 54 SC, S3/4″ IG − LoĒ2−272® − Argon Lami SDLN < 1″ 0.33 0.26 0.43 54 SC, S3/4″ IG − LoĒ2−272® − Argon Lami SDLN > 1″ 0.33 0.23 0.39 54 SC, S3/4″ IG − LoĒ3 366® Lami 0.37 0.20 0.43 50 S3/4″ IG − LoĒ3 366® − Argon Lami 0.32 0.20 0.43 54 NC, SC, S3/4″ IG − LoĒ3 366® − Lami SDLS < 1″ 0.38 0.18 0.39 50 S3/4″ IG − LoĒ3 366® − Lami SDLS > 1″ 0.38 0.17 0.35 50 S3/4″ IG − LoĒ3 366® − Lami SDLN < 1″ 0.37 0.18 0.39 50 S3/4″ IG − LoĒ3 366® − Lami SDLN > 1″ 0.37 0.17 0.35 50 S3/4″ IG − LoĒ3 366® − Argon Lami, SDLS < 1″ 0.34 0.18 0.39 54 SC, S3/4″ IG − LoĒ3 366® − Argon Lami, SDLS > 1″ 0.33 0.16 0.35 54 SC, S3/4″ IG − LoĒ3 366® − Argon Lami, SDLN < 1″ 0.32 0.18 0.39 54 NC, SC, S3/4″ IG − LoĒ3 366® − Argon, Lami SDLN > 1″ 0.32 0.16 0.35 54 NC, SC, S3/4″ IG − LoĒ3 366® − Lami GBG 0.38 0.18 0.39 50 S3/4″ IG − LoĒ3 366® − Argon Lami, GBG 0.34 0.18 0.39 54 SC, S
NOTE: >1″ and <1″ are referring to the overall bar size.Product Values are determined using the National Fenestration Rating Council (NFRC) Procedures for determining fenestration product values.U−Value: (Btu/hr−sq ft−*F) Lower the U−Value, the greater the resistance to heat flow and better its insulating value.R−Value: (1/U−Value) Higher the R−Value, the greater the resistance to heat flow and better its insulating value.Solar Heat Gain Coefficient (SHGC): The lower a window’s SHGC, the less solar heat it transmits, and the greater its shading ability.Visible Light Transmittance (VLT): Percentage of visible light transmitted through the unit.Condensation Resistance (CR): Condensation Resistance measures the ability of a product to resist the formation of condensation on the interiorsurface of a product.The higher the CR rating, the better that product is at resisting condensation formation.Capillary tubes are required for IG units at high elevations. Argon will not be furnished in units with capillary tubes.Values listed are common glazing options, call 800−346−3363 for additional NFRC unit values.
CLAD ULTIMATE CASEMENT
NFRC THERMAL PERFORMANCE − IMPACT ZONE 3
1A.1411708324
Marvin Architectural Detail Manual2011−02−28
Most Common NFRC Thermal Performance ValuesClad Ultimate Casement PictureSize Tested Frame OM 47� x 59�
Energy DataU
Value
Solar HeatGain
CoefficientVisible Light
TransmittanceCondensation
Resistance Energy Star3/4″ IG − Air 0.45 0.62 0.65 43 −3/4″ IG − LoĒ2−272® − Air 0.31 0.33 0.57 54 NC3/4″ IG − LoĒ2−272® − Argon 0.28 0.33 0.57 58 N, NC3/4″ IG − LoĒ2−272® − Air − GBG 0.31 0.30 0.51 54 NC, SC3/4″ IG − LoĒ2−272® − Argon − GBG 0.28 0.30 0.51 58 N, NC, SC3/4″ IG − LoĒ2−272® − Air SDLS < 1″ 0.33 0.30 0.51 54 SC3/4″ IG − LoĒ2−272® − Air SDLS > 1″ 0.32 0.27 0.45 54 NC, SC, S3/4″ IG − LoĒ2−272® − Air SDLN < 1″ 0.31 0.30 0.51 54 NC, SC3/4″ IG − LoĒ2−272® − Air SDLN > 1″ 0.31 0.27 0.45 54 NC, SC, S3/4″ IG − LoĒ2−272® − Argon SDLS < 1″ 0.29 0.30 0.51 58 N, NC, SC3/4″ IG − LoĒ2−272® − Argon SDLS > 1″ 0.29 0.27 0.45 58 N, NC, SC, S3/4″ IG − LoĒ2−272® − Argon SDLN < 1″ 0.28 0.30 0.51 58 N, NC, SC3/4″ IG − LoĒ2−272® − Argon SDLN > 1″ 0.28 0.27 0.45 58 N, NC, SC, S3/4″ IG − LoĒ3-366® 0.31 0.22 0.51 55 NC, SC, S3/4″ IG − LoĒ3-366® − Argon 0.27 0.22 0.51 58 N, NC, SC, S3/4″ IG − LoĒ3-366® − SDLS < 1″ 0.32 0.20 0.46 55 SC, S3/4″ IG − LoĒ3-366® − SDLS > 1″ 0.32 0.18 0.41 55 SC, S3/4″ IG − LoĒ3-366® − SDLN < 1″ 0.31 0.20 0.46 55 NC, SC, S3/4″ IG − LoĒ3-366® − SDLN > 1″ 0.31 0.18 0.41 55 NC, SC, S3/4″ IG − LoĒ3-366® − Argon, SDLS < 1″ 0.28 0.20 0.46 58 N, NC, SC, S3/4″ IG − LoĒ3-366® − Argon, SDLS > 1″ 0.28 0.18 0.41 58 N, NC, SC, S3/4″ IG − LoĒ3-366® − Argon, SDLN < 1″ 0.27 0.20 0.46 58 N, NC, SC, S3/4″ IG − LoĒ3-366® − Argon, SDLN > 1″ 0.27 0.18 0.41 58 N, NC, SC, S3/4″ IG − LoĒ3-366® − Air − GBG 0.31 0.20 0.46 55 NC, SC, S3/4″ IG − LoĒ3-366® − Argon − GBG 0.27 0.20 0.46 58 N, NC, SC, S
NOTE: >1″ and <1″ are referring to the overall bar size.
Product Values are determined using the National Fenestration Rating Council (NFRC) Procedures for determining fenestration product values.U−Value: (Btu/hr−sq ft−*F) Lower the U−Value, the greater the resistance to heat flow and better its insulating value.R−Value: (1/U−Value) Higher the R−Value, the greater the resistance to heat flow and better its insulating value.Solar Heat Gain Coefficient (SHGC): The lower a window’s SHGC, the less solar heat it transmits, and the greater its shading ability.Visible Light Transmittance (VLT): Percentage of visible light transmitted through the unit.Condensation Resistance (CR): Condensation Resistance measures the ability of a product to resist the formation of condensation on the interior
surface of a product.The higher the CR rating, the better that product is at resisting condensation formation.Capillary tubes are required for IG units at high elevations. Argon will not be furnished in units with capillary tubes.Values listed are common glazing options, call 800−346−3363 for additional NFRC unit values.
For safety and/or code requirements, Marvin recommends tempered glass in all units with a Frame Size height of71 1/8� or larger.
Units with Frame Size 25.2 sq. ft. and larger may require tempered glass.
CLAD ULTIMATE CASEMENT PICTURE
NFRC Thermal Performance − 3/4″ IG
1A.1511708324
Marvin Architectural Detail Manual2011−04−25
Most Common NFRC Thermal Performance Values Most Common NFRC Thermal Performance ValuesClad Ultimate Casement Picture
Size Tested Frame OM 47� x 59� − 1� IG
Energy DataU
Value
Solar HeatGain
CoefficientVisible Light
TransmittanceCondensation
Resistance Energy Star1″ IG − Air 0.45 0.59 0.64 43 −1″ IG − LoĒ2−272® − Air 0.32 0.32 0.56 53 NC1″ IG − LoĒ2−272® − Argon 0.28 0.32 0.56 56 N, NC1″ IG − LoĒ2−272® − Air − GBG 0.32 0.29 0.50 53 NC, SC1″ IG − LoĒ2−272® − Argon − GBG 0.28 0.29 0.50 56 N, NC, SC1″ IG − LoĒ2−272® − Air SDLS < 1″ 0.33 0.29 0.50 53 SC1″ IG − LoĒ2−272® − Air SDLS > 1″ 0.33 0.26 0.44 53 SC, S1″ IG − LoĒ2−272® − Air SDLN < 1″ 0.32 0.29 0.50 53 NC, SC1″ IG − LoĒ2−272® − Air SDLN > 1″ 0.32 0.26 0.44 53 NC, SC, S1″ IG − LoĒ2−272® − Argon SDLS < 1″ 0.29 0.29 0.50 56 N, NC, SC1″ IG − LoĒ2−272® − Argon SDLS > 1″ 0.29 0.26 0.44 56 N, NC, SC, S1″ IG − LoĒ2−272® − Argon SDLN < 1″ 0.28 0.29 0.50 56 N, NC, SC1″ IG − LoĒ2−272® − Argon SDLN > 1″ 0.28 0.26 0.44 56 N, NC, SC, S1″ IG − LoĒ3-366® 0.31 0.22 0.50 54 NC, SC, S1″ IG − LoĒ3-366® − Argon 0.28 0.22 0.50 57 N, NC, SC, S1″ IG − LoĒ3-366® − SDLS < 1″ 0.33 0.20 0.45 54 SC, S1″ IG − LoĒ3-366® − SDLS > 1″ 0.32 0.18 0.40 54 SC, S1″ IG − LoĒ3-366® − SDLN < 1″ 0.31 0.20 0.45 54 NC, SC, S1″ IG − LoĒ3-366® − SDLN > 1″ 0.31 0.18 0.40 54 NC, SC, S1″ IG − LoĒ3-366® − Argon, SDLS < 1″ 0.29 0.20 0.45 57 N, NC, SC, S1″ IG − LoĒ3-366® − Argon, SDLS > 1″ 0.29 0.18 0.40 57 N, NC, SC, S1″ IG − LoĒ3-366® − Argon, SDLN < 1″ 0.28 0.20 0.45 57 N, NC, SC, S1″ IG − LoĒ3-366® − Argon, SDLN > 1″ 0.28 0.18 0.40 57 N, NC, SC, S1″ IG − LoĒ3-366® − Air − GBG 0.31 0.20 0.45 54 NC, SC, S1″ IG − LoĒ3-366® − Argon − GBG 0.28 0.20 0.45 57 N, NC, SC, S1″ IG − Tri−pane LoĒ 180� Argon LoĒ 180� 0.22 0.45 0.55 65 N1″ IG − Tri−pane LoĒ 180� Argon LoĒ 180� SDLN < 1″ 0.22 0.41 0.49 65 N1″ IG − Tri−pane LoĒ 180� Argon LoĒ 180� SDLN > 1″ 0.22 0.36 0.43 65 N, NC1″ IG − Tri−pane LoĒ 180� Krypton/Argon LoĒ 180� 0.20 0.45 0.55 67 N1″ IG − Tri−pane LoĒ 180� Krypton/Argon LoĒ 180� SDLN < 1″ 0.20 0.41 0.49 67 N1″ IG − Tri−pane LoĒ 180� Krypton/Argon LoĒ 180� SDLN > 1″ 0.20 0.36 0.43 67 N, NC1″ IG − Tri−pane LoĒ2 272® Argon LoĒ2 272® 0.21 0.28 0.45 67 N, NC, SC1″ IG − Tri−pane LoĒ2 272® Argon LoĒ2 272® SDLN < 1″ 0.21 0.25 0.41 67 N, NC, SC, S1″ IG − Tri−pane LoĒ2 272® Argon LoĒ2 272® SDLN > 1″ 0.21 0.23 0.36 67 N, NC, SC, S1″ IG − Tri−pane LoĒ2 272® Krypton/Argon LoĒ2 272® 0.18 0.28 0.45 69 N, NC, SC1″ IG − Tri−pane LoĒ2 272® Krypton/Argon LoĒ2 272® SDLN < 1″ 0.18 0.25 0.41 69 N, NC, SC, S1″ IG − Tri−pane LoĒ2 272® Krypton/Argon LoĒ2 272® SDLN > 1″ 0.18 0.23 0.36 69 N, NC, SC, S
NOTE: >1″ and <1″ are referring to the overall bar size.
Product Values are determined using the National Fenestration Rating Council (NFRC) Procedures for determining fenestration product values.U−Value: (Btu/hr−sq ft−*F) Lower the U−Value, the greater the resistance to heat flow and better its insulating value.R−Value: (1/U−Value) Higher the R−Value, the greater the resistance to heat flow and better its insulating value.Solar Heat Gain Coefficient (SHGC): The lower a window’s SHGC, the less solar heat it transmits, and the greater its shading ability.Visible Light Transmittance (VLT): Percentage of visible light transmitted through the unit.Condensation Resistance (CR): Condensation Resistance measures the ability of a product to resist the formation of condensation on the interior
surface of a product.The higher the CR rating, the better that product is at resisting condensation formation.Capillary tubes are required for IG units at high elevations. Argon will not be furnished in units with capillary tubes.Values listed are common glazing options, call 800−346−3363 for additional NFRC unit values.
For safety and/or code requirements, Marvin recommends tempered glass in all units with a Frame Size height of71 1/8� or larger.
Units with Frame Size 25.2 sq. ft. and larger may require tempered glass.
CLAD ULTIMATE CASEMENT PICTURE
NFRC Thermal Performance − 1″ IG
1A.1611708324
Marvin Architectural Detail Manual2011−02−28
Most Common NFRC Thermal Performance ValuesClad Ultimate Push Out Casement Picture
Size Tested Frame OM 47� x 59�
Energy DataU
Value
Solar HeatGain
CoefficientVisible Light
TransmittanceCondensation
Resistance Energy Star3/4″ IG − Air 0.46 0.62 0.65 43 −3/4″ IG − LoĒ2−272® − Air 0.32 0.33 0.57 55 NC3/4″ IG − LoĒ2−272® − Argon 0.28 0.33 0.57 58 N, NC3/4″ IG − LoĒ2−272® − Air − GBG 0.32 0.30 0.51 55 NC, SC3/4″ IG − LoĒ2−272® − Argon − GBG 0.28 0.30 0.51 58 N, NC, SC3/4″ IG − LoĒ2−272® − Air SDLS < 1″ 0.33 0.30 0.51 55 SC3/4″ IG − LoĒ2−272® − Air SDLS > 1″ 0.33 0.27 0.45 55 SC, S3/4″ IG − LoĒ2−272® − Air SDLN < 1″ 0.32 0.30 0.51 55 NC, SC3/4″ IG − LoĒ2−272® − Air SDLN > 1″ 0.31 0.27 0.45 55 NC, SC, S3/4″ IG − LoĒ2−272® − Argon SDLS < 1″ 0.29 0.30 0.51 58 N, NC, SC3/4″ IG − LoĒ2−272® − Argon SDLS > 1″ 0.29 0.27 0.45 58 N, NC, SC, S3/4″ IG − LoĒ2−272® − Argon SDLN < 1″ 0.28 0.30 0.51 58 N, NC, SC3/4″ IG − LoĒ2−272® − Argon SDLN > 1″ 0.28 0.27 0.45 58 N, NC, SC, S3/4″ IG − LoĒ3-366® 0.31 0.22 0.51 55 NC, SC, S3/4″ IG − LoĒ3-366® − Argon 0.28 0.22 0.51 59 N, NC, SC, S3/4″ IG − LoĒ3-366® − SDLS < 1″ 0.33 0.20 0.46 55 SC, S3/4″ IG − LoĒ3-366® − SDLS > 1″ 0.32 0.18 0.41 55 SC, S3/4″ IG − LoĒ3-366® − SDLN < 1″ 0.31 0.20 0.46 55 NC, SC, S3/4″ IG − LoĒ3-366® − SDLN > 1″ 0.31 0.18 0.41 55 NC, SC, S3/4″ IG − LoĒ3-366® − Argon, SDLS < 1″ 0.28 0.20 0.46 59 N, NC, SC, S3/4″ IG − LoĒ3-366® − Argon, SDLS > 1″ 0.29 0.18 0.41 59 N, NC, SC, S3/4″ IG − LoĒ3-366® − Argon, SDLN < 1″ 0.28 0.20 0.46 59 N, NC, SC, S3/4″ IG − LoĒ3-366® − Argon, SDLN > 1″ 0.28 0.18 0.41 59 N, NC, SC, S3/4″ IG − LoĒ3-366® − Air − GBG 0.31 0.20 0.46 55 NC, SC, S3/4″ IG − LoĒ3-366® − Argon − GBG 0.28 0.20 0.46 59 N, NC, SC, S
NOTE: >1″ and <1″ are referring to the overall bar size.
Product Values are determined using the National Fenestration Rating Council (NFRC) Procedures for determining fenestration product values.U−Value: (Btu/hr−sq ft−*F) Lower the U−Value, the greater the resistance to heat flow and better its insulating value.R−Value: (1/U−Value) Higher the R−Value, the greater the resistance to heat flow and better its insulating value.Solar Heat Gain Coefficient (SHGC): The lower a window’s SHGC, the less solar heat it transmits, and the greater its shading ability.Visible Light Transmittance (VLT): Percentage of visible light transmitted through the unit.Condensation Resistance (CR): Condensation Resistance measures the ability of a product to resist the formation of condensation on the interior
surface of a product.The higher the CR rating, the better that product is at resisting condensation formation.Capillary tubes are required for IG units at high elevations. Argon will not be furnished in units with capillary tubes.Values listed are common glazing options, call 800−346−3363 for additional NFRC unit values.
For safety and/or code requirements, Marvin recommends tempered glass in all units with a Frame Size height of71 1/8� or larger.
Units with Frame Size 25.2 sq. ft. and larger may require tempered glass.
CLAD ULTIMATE PUSH OUT CASEMENT PICTURE
NFRC Thermal Performance CUPCAP − 3/4″ IG
1A.1711708324
Marvin Architectural Detail Manual2011−04−25
Most Common NFRC Thermal Performance Values Most Common NFRC Thermal Performance ValuesClad Ultimate Casement Picture
Size Tested Frame OM 47� x 59� − 1� IG
Energy DataU
Value
Solar HeatGain
CoefficientVisible Light
TransmittanceCondensation
Resistance Energy Star1″ IG − Air 0.45 0.59 0.64 43 −1″ IG − LoĒ2−272® − Air 0.32 0.33 0.56 54 NC1″ IG − LoĒ2−272® − Argon 0.29 0.32 0.56 57 N, NC1″ IG − LoĒ2−272® − Air − GBG 0.32 0.29 0.50 54 NC, SC1″ IG − LoĒ2−272® − Argon − GBG 0.29 0.29 0.50 57 N, NC, SC1″ IG − LoĒ2−272® − Air SDLS < 1″ 0.34 0.29 0.50 54 SC1″ IG − LoĒ2−272® − Air SDLS > 1″ 0.33 0.26 0.44 54 SC, S1″ IG − LoĒ2−272® − Air SDLN < 1″ 0.32 0.29 0.50 54 NC, SC1″ IG − LoĒ2−272® − Air SDLN > 1″ 0.32 0.26 0.44 54 NC, SC, S1″ IG − LoĒ2−272® − Argon SDLS < 1″ 0.30 0.29 0.50 57 N, NC, SC1″ IG − LoĒ2−272® − Argon SDLS > 1″ 0.30 0.26 0.44 57 N, NC, SC, S1″ IG − LoĒ2−272® − Argon SDLN < 1″ 0.29 0.29 0.50 57 N, NC, SC1″ IG − LoĒ2−272® − Argon SDLN > 1″ 0.29 0.26 0.44 57 N, NC, SC, S1″ IG − LoĒ3-366® 0.32 0.22 0.50 54 NC, SC, S1″ IG − LoĒ3-366® − Argon 0.28 0.22 0.50 57 N, NC, SC, S1″ IG − LoĒ3-366® − SDLS < 1″ 0.33 0.20 0.45 54 SC, S1″ IG − LoĒ3-366® − SDLS > 1″ 0.33 0.18 0.40 54 SC, S1″ IG − LoĒ3-366® − SDLN < 1″ 0.32 0.20 0.45 54 NC, SC, S1″ IG − LoĒ3-366® − SDLN > 1″ 0.32 0.18 0.40 54 NC, SC, S1″ IG − LoĒ3-366® − Argon, SDLS < 1″ 0.29 0.20 0.45 57 N, NC, SC, S1″ IG − LoĒ3-366® − Argon, SDLS > 1″ 0.29 0.18 0.40 57 N, NC, SC, S1″ IG − LoĒ3-366® − Argon, SDLN < 1″ 0.28 0.20 0.45 57 N, NC, SC, S1″ IG − LoĒ3-366® − Argon, SDLN > 1″ 0.28 0.18 0.40 57 N, NC, SC, S1″ IG − LoĒ3-366® − Air − GBG 0.32 0.20 0.45 54 NC, SC, S1″ IG − LoĒ3-366® − Argon − GBG 0.28 0.20 0.45 57 N, NC, SC, S1″ IG − Tri−pane LoĒ 180� Argon LoĒ 180� 0.23 0.45 0.55 66 N1″ IG − Tri−pane LoĒ 180� Argon LoĒ 180� SDLN < 1″ 0.23 0.41 0.49 66 N1″ IG − Tri−pane LoĒ 180� Argon LoĒ 180� SDLN > 1″ 0.23 0.36 0.43 66 N, NC1″ IG − Tri−pane LoĒ 180� Krypton/Argon LoĒ 180� 0.20 0.45 0.55 68 N1″ IG − Tri−pane LoĒ 180� Krypton/Argon LoĒ 180� SDLN < 1″ 0.20 0.41 0.49 68 N1″ IG − Tri−pane LoĒ 180� Krypton/Argon LoĒ 180� SDLN > 1″ 0.20 0.36 0.43 68 N, NC1″ IG − Tri−pane LoĒ2 272® Argon LoĒ2 272® 0.21 0.28 0.45 67 N, NC, SC1″ IG − Tri−pane LoĒ2 272® Argon LoĒ2 272® SDLN < 1″ 0.21 0.25 0.41 67 N, NC, SC, S1″ IG − Tri−pane LoĒ2 272® Argon LoĒ2 272® SDLN > 1″ 0.21 0.23 0.36 67 N, NC, SC, S1″ IG − Tri−pane LoĒ2 272® Krypton/Argon LoĒ2 272® 0.19 0.28 0.45 70 N, NC, SC1″ IG − Tri−pane LoĒ2 272® Krypton/Argon LoĒ2 272® SDLN < 1″ 0.19 0.25 0.41 70 N, NC, SC, S1″ IG − Tri−pane LoĒ2 272® Krypton/Argon LoĒ2 272® SDLN > 1″ 0.19 0.23 0.36 70 N, NC, SC, S
NOTE: >1″ and <1″ are referring to the overall bar size.
Product Values are determined using the National Fenestration Rating Council (NFRC) Procedures for determining fenestration product values.U−Value: (Btu/hr−sq ft−*F) Lower the U−Value, the greater the resistance to heat flow and better its insulating value.R−Value: (1/U−Value) Higher the R−Value, the greater the resistance to heat flow and better its insulating value.Solar Heat Gain Coefficient (SHGC): The lower a window’s SHGC, the less solar heat it transmits, and the greater its shading ability.Visible Light Transmittance (VLT): Percentage of visible light transmitted through the unit.Condensation Resistance (CR): Condensation Resistance measures the ability of a product to resist the formation of condensation on the interior
surface of a product.The higher the CR rating, the better that product is at resisting condensation formation.Capillary tubes are required for IG units at high elevations. Argon will not be furnished in units with capillary tubes.Values listed are common glazing options, call 800−346−3363 for additional NFRC unit values.
For safety and/or code requirements, Marvin recommends tempered glass in all units with a Frame Size height of71 1/8� or larger.
Units with Frame Size 25.2 sq. ft. and larger may require tempered glass.
CLAD ULTIMATE PUSH OUT CASEMENT
NFRC Thermal Performance − 1″ IG
1A.1811708324
Marvin Architectural Detail Manual2011−02−28
Most Common NFRC Thermal Performance ValuesClad Ultimate Casement Picture
Size Tested Frame OM 47� x 59� − 3/4� IZ3
Energy Data U−Value SHGC VLT CR Energy Star3/4″ IG − Air Lami 0.43 0.57 0.63 44 −3/4″ IG − LoĒ2−272® − Air Lami 0.32 0.32 0.55 52 NC3/4″ IG − LoĒ2−272® − Argon Lami 0.28 0.32 0.55 55 N, NC3/4″ IG − LoĒ2−272® − Air Lami − GBG 0.33 0.29 0.49 52 SC3/4″ IG − LoĒ2−272® − Argon Lami − GBG 0.29 0.29 0.49 55 N, NC, SC3/4″ IG − LoĒ2−272® − Air Lami SDLS < 1″ 0.33 0.29 0.49 52 SC3/4″ IG − LoĒ2−272® − Air Lami SDLS > 1″ 0.33 0.26 0.44 52 SC, S3/4″ IG − LoĒ2−272® − Air Lami SDLN < 1″ 0.32 0.29 0.49 52 NC, SC3/4″ IG − LoĒ2−272® − Air Lami SDLN > 1″ 0.32 0.26 0.44 52 NC, SC, S3/4″ IG − LoĒ2−272® − Argon Lami SDLS < 1″ 0.28 0.29 0.49 58 N, NC, SC3/4″ IG − LoĒ2−272® − Argon Lami SDLS > 1″ 0.28 0.26 0.44 58 N, NC, SC, S3/4″ IG − LoĒ2−272® − Argon Lami SDLN < 1″ 0.27 0.29 0.49 58 N, NC, SC3/4″ IG − LoĒ2−272® − Argon Lami SDLN > 1″ 0.30 0.26 0.44 55 N, NC, SC, S3/4″ IG − LoĒ3-366® Air Lami 0.32 0.22 0.49 52 NC, SC, S3/4″ IG − LoĒ3-366® − Argon Lami 0.27 0.22 0.49 56 N, NC, SC, S3/4″ IG − LoĒ3-366® − Air Lami SDLS < 1″ 0.33 0.20 0.44 52 SC, S3/4″ IG − LoĒ3-366® − Air Lami SDLS > 1″ 0.33 0.18 0.39 52 SC, S3/4″ IG − LoĒ3-366® − Air Lami SDLN< 1″ 0.32 0.20 0.44 52 NC, SC, S3/4″ IG − LoĒ3-366® − Air Lami SDLN > 1″ 0.32 0.18 0.39 52 NC, SC, S3/4″ IG − LoĒ3-366® − Argon Lami, SDLS< 1″ 0.28 0.20 0.44 56 N, NC, SC, S3/4″ IG − LoĒ3-366® − Argon Lami, SDLS > 1″ 0.28 0.18 0.39 56 N, NC, SC, S3/4″ IG − LoĒ3-366® − Argon Lami, SDLN < 1″ 0.27 0.20 0.44 56 N, NC, SC, S3/4″ IG − LoĒ3-366® − Argon Lami, SDLN > 1″ 0.27 0.18 0.39 56 N, NC, SC, S
NOTE: >1″ and <1″ are referring to the overall bar size.
Product Values are determined using the National Fenestration Rating Council (NFRC) Procedures for determining fenestration product values.U−Value: (Btu/hr−sq ft−*F) Lower the U−Value, the greater the resistance to heat flow and better its insulating value.R−Value: (1/U−Value) Higher the R−Value, the greater the resistance to heat flow and better its insulating value.Solar Heat Gain Coefficient (SHGC): The lower a window’s SHGC, the less solar heat it transmits, and the greater its shading ability.Visible Light Transmittance (VLT): Percentage of visible light transmitted through the unit.Condensation Resistance (CR): Condensation Resistance measures the ability of a product to resist the formation of condensation on the interior
surface of a product.The higher the CR rating, the better that product is at resisting condensation formation.Capillary tubes are required for IG units at high elevations. Argon will not be furnished in units with capillary tubes.Values listed are common glazing options, call 800−346−3363 for additional NFRC unit values.
For safety and/or code requirements, Marvin recommends tempered glass in all units with a Frame Size height of71 1/8� or larger.
Units with Frame Size 25.2 sq. ft. and larger may require tempered glass.
CLAD ULTIMATE CASEMENT PICTURE
NFRC Thermal Performance CUCAP − 3/4″ IMPACT ZONE 3
1A.1911708324
Marvin Architectural Detail Manual2011−02−28
Most Common NFRC Thermal Performance Values Most Common NFRC Thermal Performance ValuesClad Ultimate Casement Picture
Size Tested Frame OM 47� x 59� − 1� IZ3
Energy Data U−Value SHGC VLT CR Energy Star1″ IG − Air Lami 0.45 0.56 0.63 42 −1″ IG − LoĒ2−272® − Air Lami 0.32 0.32 0.55 52 NC1″ IG − LoĒ2−272® − Argon Lami 0.28 0.32 0.55 55 N, NC1″ IG − LoĒ2−272® − Air Lami − GBG 0.33 0.29 0.49 52 SC1″ IG − LoĒ2−272® − Argon Lami − GBG 0.29 0.29 0.49 55 N, NC, SC1″ IG − LoĒ2−272® − Air Lami SDLS < 1″ 0.33 0.29 0.49 52 SC1″ IG − LoĒ2−272® − Air Lami SDLS > 1″ 0.33 0.26 0.44 52 SC, S1″ IG − LoĒ2−272® − Air Lami SDLN < 1″ 0.32 0.29 0.49 52 NC, SC1″ IG − LoĒ2−272® − Air Lami SDLN > 1″ 0.32 0.26 0.44 52 NC, SC, S1″ IG − LoĒ2−272® − Argon Lami SDLS < 1″ 0.29 0.29 0.49 55 N, NC, SC1″ IG − LoĒ2−272® − Argon Lami SDLS > 1″ 0.29 0.26 0.44 55 N, NC, SC, S1″ IG − LoĒ2−272® − Argon Lami SDLN < 1″ 0.28 0.29 0.49 55 N, NC, SC1″ IG − LoĒ2−272® − Argon Lami SDLN > 1″ 0.28 0.26 0.44 55 N, NC, SC, S1″ IG − LoĒ3-366® Air Lami 0.32 0.22 0.49 52 NC, SC, S1″ IG − LoĒ3-366® − Argon Lami 0.27 0.22 0.49 56 N, NC, SC, S1″ IG − LoĒ3-366® − Air Lami SDLS < 1″ 0.33 0.20 0.44 52 SC, S1″ IG − LoĒ3-366® − Air Lami SDLS > 1″ 0.33 0.18 0.39 52 SC, S1″ IG − LoĒ3-366® − Air Lami SDLN< 1″ 0.32 0.20 0.44 52 NC, SC, S1″ IG − LoĒ3-366® − Air Lami SDLN > 1″ 0.32 0.18 0.39 52 NC, SC, S1″ IG − LoĒ3-366® − Argon Lami, SDLS< 1″ 0.28 0.20 0.44 56 N, NC, SC, S1″ IG − LoĒ3-366® − Argon Lami, SDLS > 1″ 0.28 0.18 0.39 56 N, NC, SC, S1″ IG − LoĒ3-366® − Argon Lami, SDLN < 1″ 0.27 0.20 0.44 56 N, NC, SC, S1″ IG − LoĒ3-366® − Argon Lami, SDLN > 1″ 0.27 0.18 0.39 56 N, NC, SC, S1″ IG − LoĒ3-366® − Air Lami − GBG 0.32 0.22 0.49 52 NC, SC, S1″ IG − LoĒ3-366® − Argon Lami − GBG 0.28 0.20 0.44 56 N, NC, SC, S
NOTE: >1″ and <1″ are referring to the overall bar size.
Product Values are determined using the National Fenestration Rating Council (NFRC) Procedures for determining fenestration product values.U−Value: (Btu/hr−sq ft−*F) Lower the U−Value, the greater the resistance to heat flow and better its insulating value.R−Value: (1/U−Value) Higher the R−Value, the greater the resistance to heat flow and better its insulating value.Solar Heat Gain Coefficient (SHGC): The lower a window’s SHGC, the less solar heat it transmits, and the greater its shading ability.Visible Light Transmittance (VLT): Percentage of visible light transmitted through the unit.Condensation Resistance (CR): Condensation Resistance measures the ability of a product to resist the formation of condensation on the interior
surface of a product.The higher the CR rating, the better that product is at resisting condensation formation.Capillary tubes are required for IG units at high elevations. Argon will not be furnished in units with capillary tubes.Values listed are common glazing options, call 800−346−3363 for additional NFRC unit values.
For safety and/or code requirements, Marvin recommends tempered glass in all units with a Frame Size height of71 1/8� or larger.
Units with Frame Size 25.2 sq. ft. and larger may require tempered glass.
CLAD ULTIMATE CASEMENT PICTURE
NFRC Thermal Performance CUCAP − 1″ IMPACT ZONE 3
1A.2011708324
Marvin Architectural Detail Manual2012−04−30
Clad Ultimate Casement Maximum CertifiedSizes and Rating − Operable Casement
Clad Ultimate Push Out Casement Maximum CertifiedSize and Ratings for Operable Casement Units
Frame HeightInches
Nominal WidthFrame Width, Inches Frame Height,
Inches
Nominal WidthFrame Width, Inches
36 (914) 40 (1016) 36 (914) 40 (1016)
71 1/8 (1807) CW−PG50−C* C−C50* 71 1/8 (1807) CW−PG50−C* CW−PG35−C
92 (2337) CW−PG50−C C−C50 92 (2337) CW−PG35−C CW−PG35−C
96 1/8 (2442) CW−PG50−C N/A 96 1/8 (2442) CW−PG35−C N/A
*Units certified with nailing fin only instructions. All other larger units require screw through thejamb installation to perform the certified rating.
Minimum and Maximum Guidelines − Ultimate Casement − Operators
Unit TypeFrame Size
MinimumSize Unit
MaximumSize Unit
Insulating Glass 3/4″ (19) or 1″ (25) Operator 14″ (356) X 11 1/2″ (292) 36″ (914) x 96 1/8″ (2442)40″ (1016) x 92″ (2337)
* If width is greater than 36″ (914) = 92″ (2237)If width is less than or equal to 36″ (914) = 96 1/8″ (2442)
Minimum and Maximum Guidelines − Ultimate Casement Push Out − Operators
Unit TypeFrame Size
MinimumSize Unit
MaximumSize Unit
Insulating Glass 3/4″ (19) or 1″ (25) Operator 16″ (406) X 15″ (381) Std Btm Rail16″ (406) X 17 3/8″ (441) Tall Btm Rail
36″ (914) x 96 1/8″ (2442)40″ (1016) x 92″ (2337)
*Maximum sash weight for operating casement and operating push out casements 145 lbs.
Minimum and Maximum Guidelines − Retractable Screen
Unit TypeFrame Size
MinimumSize Unit
MaximumSize Unit
CUCA 14″ (356) X 19 1/8″ (486) 40″ (1016) X 59 1/8″ (1502)36″ (914) X 71 1/8″ (1807)
CUPCA 14″ (356) X 19 1/8″ (486) 40″ (1016) X 59 1/8″ (1502)36″ (914) X 71 1/8″ (1807)
NOTE:These minimum and maximum measurements are guidelines for configuring custom sized units, all measurementsare specific to glass type. For assistance please call 800−346−3363 or your Marvin representative.
CLAD ULTIMATE CASEMENT/PUSH OUT CASEMENT
CERTIFIED SIZES AND RATINGS, MINIMUM AND MAXIMUM GUIDELINES
1A.2111708324
Marvin Architectural Detail Manual2012−04−30
Certified Minimum and Maximum Guidelines − CUCAP and CUPCAP
Unit TypeFrame Size
MinimumSize Unit
MaximumSize Unit
Insulating Glass 3/4″ (19) Picture 12″ (305) x 11 1/8″ (283)64″ (1626) x 95 1/8″ (2416)
96″ (2438) x 63 1/8″ (1603)
Insulating Glass 1″ (25) Picture 12″ (305) x 11 1/8″ (283)96″ (2438) x 83 1/8″ (2111)
88″ (2235) x 95 1/8″ (2416)
Maximum Certified Sizes and Rating − CUCAP and CUPCAP
Frame HeightInches
Nominal WidthFrame Width, inches
64.000 (1626) 72.000 (1829) 88.000 (2235) 96 1/8 (2442)
63 1/8 (1603) CW−PG50−FW* CW−PG50−FW* CW−PG50−FW CW−PG50−FW
71 1/8 (1807) CW−PG50−FW* CW−PG50−FW* CW−PG50−FW CW−PG50−FW
87 1/8 (2213) CW−PG50−FW CW−PG50−FW CW−PG50−FW CW−PG50−FW
95 1/8 (2416) CW−PG50−FW CW−PG50−FW CW−PG50−FW N/A
*Units certified with nailing fin only instructions. All other larger units require screw through thejamb installation to perform the certified rating.
NOTE:These minimum and maximum measurements are guidelines for configuring custom sized units, all measurementsare specific to glass type. For assistance please call 800−346−3363 or your Marvin representative.
CLAD ULTIMATE CASEMENT/PUSH OUT CASEMENT
CERTIFIED SIZES AND RATINGS, MINIMUM AND MAXIMUM GUIDELINES
1A.2211708324
Marvin Architectural Detail Manual2012−04−30
IZ3 Clad Ultimate Casement Maximum CertifiedSizes and Rating − Operable Casement
Frame HeightInches
Nominal WidthFrame Width, Inches
36
71 1/8 (1807) CW−PG65−C
83 1/8 (2111) CW−PG65−C
96 1/8 (2442) CW−PG65−C
* Units certified with nailing fin only instructions. All other larger units require screw through thejamb installation to perform the certified rating.
IZ3 Minimum and Maximum Guidelines − Ultimate Casement − Operators
Unit TypeFrame Size
MinimumSize Unit
MaximumSize Unit
Insulating Glass 3/4″ (19) or 1″ (25) Operator 14″ (356) X 11 1/2″ (292)
36″ (914) x 96 1/8″ (2442)(2″ Sash)
36″ (914) x 83 1/8″ (2111)(1 3/4″ Sash)
* If width is greater than 36″ (914) = 92″ (2237)If width is less than or equal to 36″ (914) = 96 1/8″ (2442)
NOTE:These minimum and maximum measurements are guidelines for configuring custom sized units, all measurementsare specific to glass type. For assistance please call 800−346−3363 or your Marvin representative.
CLAD ULTIMATE CASEMENT
CERTIFIED SIZES AND RATINGS, MINIMUM AND MAXIMUM GUIDELINES − IMPACT ZONE 3
1A.2311708324
Marvin Architectural Detail Manual2012−04−30
MEASUREMENT CONVERSIONSCLAD ULTIMATE CASEMENT/ULTIMATE PUSH OUT CASEMENT
Unit Width HeightFrame Measurements
Masonry Opening to Rough Opening (without BMC) + 1/2″ (13) + 1/4″ (6)
Masonry Opening to Rough Opening (with BMC) − 2 1/8″ (54) − 1 11/16″ (43)
Masonry Opening to Rough Opening (with Flat Casing) − 5 1/2″ (140) − 3 3/8″ (86)
Masonry Opening to OM of BMC − 1/2″ (13) − 1/4″ (6)
Masonry Opening to OM of Flat Casing − 1/2″ (13) − 1/4″ (6)
OM of Frame to Rough Opening + 1″ (25) + 1/2″ (13)
Glass Size to Rough Opening + 5 23/32″ (145) + 5 7/32″ (133)
Sash Opening to Rough Opening + 2 5/16″ (59) + 1 13/16″ (46)
Sash
Glass Size to Sash Opening + 3 13/32″ (87) + 3 13/32″ (87)
Glass Size to OM of Sash + 3 1/8″ (79) + 3 1/8″ (79)
OM of Sash to Rough Opening + 2 19/32″ (66) + 2 3/32″ (53)
Daylight Opening to Glass Size + 1 3/32″ (28) + 1 3/32″ (28)
Daylight Opening to Rough Opening + 6 13/16″ (173) + 6 5/16″ (160)
Screen
Rough Opening to OM of Screen − 5 11/16″ (144) − 5 13/32″ (137)
Daylight Opening to OM of Screen + 1 1/8″ (29) + 29/32″ (23)
Crank Out and Push Out Retractable Casement Screen
Retractable Screen to Rough Opening + 3 3/8″ (86) + 2 7/8″ (74)
Daylight Opening to Retractable Screen OM + 3 13/32″ (87) + 3 13/32″ (87)
Sash OM to Retractable Screen OM − 11/16″ (17) − 11/16″ (17)
Swinging Wood Screen (Push Out)
OM of Screen to Rough Opening + 3 19/32″ (91) + 3 3/32″ (79)
Daylight Opening to OM of Screen + 3 7/32″ (82) + 3 7/32″ (82)
Tall Bottom Rail Option
Daylight Opening to Rough Opening + 6 13/16″ (173) + 7 13/16″ (198)
Daylight Opening to OM of Screen + 1 1/8″ (29) + 2 13/32″ (61)
CLAD ULTIMATE CASEMENT
MEASUREMENT CONVERSIONS
1A.2411708324
Marvin Architectural Detail Manual2012−04−30
MEASUREMENT CONVERSIONSCLAD ULTIMATE CASEMENT/ULTIMATE PUSH OUT CASEMENT
Ultimate Crank Out CasementEgress Formula: Standard ScreenFrame OM Width 20� (508) and wider:To find clear opening width: Frame width −7 1/8″ (181).
Frame OM Width less than 20� (508):To find clear opening width: Frame width −9 9/16″ (243).
Frame OM Height:To find clear opening height: Frame OM height −5 1/8″ (130).Clear opening area (ft^2) = (clear opening width x clear opening height) /144
Vent Opening: Standard ScreenVent Opening Width = Frame OM Width − 4 31/32″ (126)Vent Opening Height = Frame OM Height − 5 1/8″ (130)
Egress Formula: Retractable ScreenFrame OM Width 20� (508) and wider:Clear Opening Width = Frame OM Width − 7 9/32″ (185)
Frame OM Width less than 20� (508):Clear Opening Width = Frame OM Width − 9 25/32″ (248)
Frame OM Height:Clear Opening Height = Frame OM Height − 5 15/32″ (139)
Vent Opening: Retractable ScreenVent Opening Width = Frame OM Width − 5 11/32″ (136)Vent Opening Height = Frame OM Height − 5 15/32″ (139)
Ultimate Push Out CasementEgress Formula: Standard ScreenFrame OM Width 20� (508) and wider:To find clear opening width: Frame width −6 3/16″ (157).
Frame OM Width less than 20� (508):To find clear opening width: Frame width −8 11/16″ (222).
Frame OM Height:To find clear opening height: Frame OM height −4 1/16″ (103).
Vent Opening: Standard ScreenVent Opening Width = Frame OM Width − 3 1/8″ (79)Vent Opening Height = Frame OM Height − 4 1/16″ (103)Vent Opening area (ft^2) = (Vent Opening Width x Vent Opening Height)/144
Egress Formula: Retractable ScreenFrame OM Width 20� (508) and wider:Clear Opening Width = Frame OM Width − 6 3/16″ (157)
Frame OM Width less then 20� (508)Clear Opening Width = Frame OM Width − 8 11/16″ (221)
Frame OM Height:Frame OM Height − 5 15/32″ (139)
Vent Opening: Retractable ScreenVent Opening Width = Frame OM Width − 4 7/32″ (107)Vent Opening Height = Frame OM Height − 5 15/32″ (139)Vent Opening area (ft^2) = (Vent Opening Width x Vent Opening Height)/144
CLAD ULTIMATE CASEMENT
MEASUREMENT CONVERSIONS
1A.2511708324
Marvin Architectural Detail Manual2012−04−30
Full Frame Standard Sizes − UltimateCasement
Operator/Stationary
Width
MO 1−4 1/2 (419) 1−6 1/2 (469) 1−8 1/2 (520) 2−1/2 (622) 2−2 1/2 (673)
RO 1−5 (431) 1−7 (482) 1−9 (533) 2−1 (635) 2−3 (685)
Height FS 1−4 (406) 1−6 (457) 1−8 (508) 2−0 (609) 2−2 (660)
MO RO FS Call Number
1−1 3/8 (339) 1−1 5/8 (346) 1−1 1/8 (333) 1614 1814 2014 2414 2614
1−3 3/8 (390) 1−3 5/8 (396) 1−3 1/8 (384) 1616 1816 2016 2416 2616
1−5 3/8 (441) 1−5 5/8 (447) 1−5 1/8 (434) 1618 1818 2018 2418 2618
1−7 3/8 (492) 1−7 5/8 (498) 1−7 1/8 (485) 1620 1820 2020 2420 2620
1−11 3/8 (593) 1−11 5/8 (600) 1−11 1/8 (587) 1624 1824 2024 2424 2624
2−3 3/8 (695) 2−3 5/8 (701) 2−3 1/8 (688) 1628 1828 2028 2428 2628
2−7 3/8 (796) 2−7 5/8 (803) 2−7 1/8 (790) 1632 1832 2032 2432 2632
2−11 3/8 (898) 2−11 5/8 (904) 2−11 1/8 (892) 1636 1836 2036 2436 2636
3−3 3/8 (1000) 3−3 5/8 (1006) 3−3 1/8 (993) 1640 1840 2040 2440 2640
3−7 3/8 (1101) 3−7 5/8 (1108) 3−7 1/8 (1095) 1644 1844 2044 2444 2644
3−11 3/8 (1203) 3−11 5/8 (1209) 3−11 1/8 (1196) 1648 1848 2048 2448 2648
4−5 3/8 (1355) 4−5 5/8 (1362) 4−5 1/8 (1349) 1654 1854 2054 2454 2654
4−7 3/8 (1406) 4−7 5/8 (1412) 4−7 1/8 (1400) 1656 1856 2056 2456 2656
4−11 3/8 (1508) 4−11 5/8 (1514) 4−11 1/8 (1501) 1660 1860 2060 2460 2660
5−3 3/8 (1609) 5−3 5/8 (1616) 5−3 1/8 (1603) 1664 1864 2064 2464 2664
5−11 3/8 (1812) 5−11 5/8 (1819) 5−11 1/8 (1806) 1672 1872 2072 2472 2672
6−5 3/8 (1965) 6−5 5/8 (1971) 6−5 1/8 (1958) 1678 1878 2078 2478 2678
6−11 3/8 (2117) 6−11 5/8 (2124) 6−11 1/8 (2111) 1684 1884 2084 2484 2684
7−7 3/8 (2320) 7−7 5/8 (2327) 7−7 1/8 (2314) 1692 1892 2092 2492 2692
7−11 3/8 (2422) 7−11 5/8 (2428) 7−11 1/8 (2416) 1696 1896 2096 2496 2696
= standard size − operator, stationary
= standard size − operator, stationary − tempered recommended or required
= not available on operator CUPCA
= not available
* These units meet national egress codes for fine evacuation. Local codes may differ.
For safety and/or code requirements, Marvin recommends tempered glass in all units with a Frame Size height of71 1/8� or larger.
Units with Frame Size 25.2 sq. ft. and larger may require tempered glass.
FS = Fame SizeRO = Rough OpeningMO = Masonry OpeningCN = Call NumberOM = Outside Measurement
CLAD ULTIMATE CASEMENT/PUSH OUT CASEMENT
STANDARD SIZES: OPERATOR AND STATIONARY
1A.2611708324
Marvin Architectural Detail Manual2012−04−30
Full Frame Standard Sizes − UltimateCasement
Operator/Stationary
Width
MO 2−4 1/2 (723) 2−6 1/2 (774) 2−8 1/2 (825) 3−1/2 (927) 3−4 1/2 (1028)
RO 2−5 (736) 2−7 (787) 2−9 (838) 3−1 (939) 3−5 (1041)
Height FS 2−4 (711) 2−6 (762) 2−8 (812) 3−0 (914) 3−4 (1016)
MO RO FS Call Number
1−1 3/8 (339) 1−1 5/8 (346) 1−1 1/8 (333) 2814 3014 3214 3614 4014
1−3 3/8 (390) 1−3 5/8 (396) 1−3 1/8 (384) 2816 3016 3216 3616 4016
1−5 3/8 (441) 1−5 5/8 (447) 1−5 1/8 (434) 2818 3018 3218 3618 4018
1−7 3/8 (492) 1−7 5/8 (498) 1−7 1/8 (485) 2820 3020 3220 3620 4020
1−11 3/8 (593) 1−11 5/8 (600) 1−11 1/8 (587) 2824 3024 3224 3624 4024
2−3 3/8 (695) 2−3 5/8 (701) 2−3 1/8 (688) 2828 3028 3228 3628 4028
2−7 3/8 (796) 2−7 5/8 (803) 2−7 1/8 (790) 2832 3032 3232 3632 4032E
2−11 3/8 (898) 2−11 5/8 (904) 2−11 1/8 (892) 2836 3036 3236 3636E 4036E
3−3 3/8 (1000) 3−3 5/8 (1006) 3−3 1/8 (993) 2840 3040E 3240E 3640E 4040E
3−7 3/8 (1101) 3−7 5/8 (1108) 3−7 1/8 (1095) 2844E 3044E 3244E 3644E 4044E
3−11 3/8 (1203) 3−11 5/8 (1209) 3−11 1/8 (1196) 2848E 3048E 3248E 3648E 4048E
4−5 3/8 (1355) 4−5 5/8 (1362) 4−5 1/8 (1349) 2854E 3054E 3254E 3654E 4054E
4−7 3/8 (1406) 4−7 5/8 (1412) 4−7 1/8 (1400) 2856E 3056E 3256E 3656E 4056E
4−11 3/8 (1508) 4−11 5/8 (1514) 4−11 1/8 (1501) 2860E 3060E 3260E 3660E 4060E
5−3 3/8 (1609) 5−3 5/8 (1616) 5−3 1/8 (1603) 2864E 3064E 3264E 3664E 4064E
5−11 3/8 (1812) 5−11 5/8 (1819) 5−11 1/8 (1806) 2872E 3072E 3272E 3672E 4072E
6−5 3/8 (1965) 6−5 5/8 (1971) 6−5 1/8 (1958) 2878E 3078E 3278E 3678E 4078E
6−11 3/8 (2117) 6−11 5/8 (2124) 6−11 1/8 (2111) 2884E 3084E 3284E 3684E 4084E
7−7 3/8 (2320) 7−7 5/8 (2327) 7−7 1/8 (2314) 2892E 3092E 3292E 3692E 4092E
7−11 3/8 (2422) 7−11 5/8 (2428) 7−11 1/8 (2416) 2896E 3096E 3296E 3696E N/A
= standard size − operator, stationary
= standard size − operator, stationary − tempered recommended or required
= not available on operator CUPCA
= not available
NOTE: “E” indicates these units meet national egress codes for fine evacuation. Local codes may differ.
For safety and/or code requirements, Marvin recommends tempered glass in all units with a Frame Size height of71 1/8� or larger.
Units with Frame Size 25.2 sq. ft. and larger may require tempered glass.
FS = Fame SizeRO = Rough OpeningMO = Masonry OpeningCN = Call NumberOM = Outside Measurement
CLAD ULTIMATE CASEMENT/PUSH OUT CASEMENT
STANDARD SIZES: OPERATOR AND STATIONARY
1A.2711708324
Marvin Architectural Detail Manual2012−01−23
Clad Ultimate Casement PictureFull Frame Standard Sizes − 3/4” IG
Stationary/Picture
Width
MO 3−4 1/2 (1028) 4−0 1/2 (469) 4−8 1/2 (1435) 5−0 1/2 (1537) 5−4 1/2 (1638)
RO 3−5 (1041) 4−1 (1245) 4−9 (1448) 5−1 (1549) 5−5 (1651)
Height FS 3−4 (1016) 4−0 (1219) 4−8 (1422) 5−0 (1524) 5−4 (1626)
MO RO FS Call Number
0−11 3/8 (289) 0−11 5/8 (295) 0−11 1/8 (283) 4012 4812 5612 6012 6412
1−1 3/8 (339) 1−1 5/8 (346) 1−1 1/8 (333) 4014 4814 5614 6014 6414
1−3 3/8 (390) 1−3 5/8 (396) 1−3 1/8 (384) 4016 4816 5616 6016 6416
1−5 3/8 (441) 1−5 5/8 (447) 1−5 1/8 (434) 4018 4818 5618 6018 6418
1−7 3/8 (492) 1−7 5/8 (498) 1−7 1/8 (485) 4020 4820 5620 6020 6420
1−11 3/8 (593) 1−11 5/8 (600) 1−11 1/8 (587) 4024 4824 5624 6024 6424
2−3 3/8 (695) 2−3 5/8 (701) 2−3 1/8 (688) 4028 4828 5628 6028 6428
2−7 3/8 (796) 2−7 5/8 (803) 2−7 1/8 (790) 4032 4832 5632 6032 6432
2−11 3/8 (898) 2−11 5/8 (904) 2−11 1/8 (892) 4036 4836 5636 6036 6436
3−3 3/8 (1000) 3−3 5/8 (1006) 3−3 1/8 (993) 4040 4840 5640 6040 6440
3−7 3/8 (1101) 3−7 5/8 (1108) 3−7 1/8 (1095) 4044 4844 5644 6044 6444
3−11 3/8 (1203) 3−11 5/8 (1209) 3−11 1/8 (1196) 4048 4848 5648 6048 6448
4−5 3/8 (1355) 4−5 5/8 (1362) 4−5 1/8 (1349) 4054 4854 5654 6054 6454
4−7 3/8 (1406) 4−7 5/8 (1412) 4−7 1/8 (1400) 4056 4856 5656 6056 6456
4−11 3/8 (1508) 4−11 5/8 (1514) 4−11 1/8 (1501) 4060 4860 5660 6060 6460
5−3 3/8 (1609) 5−3 5/8 (1616) 5−3 1/8 (1603) 4064 4864 5664 6064 6464
5−11 3/8 (1812) 5−11 5/8 (1819) 5−11 1/8 (1806) 4072 4872 5672 6072 6472
6−5 3/8 (1965) 6−5 5/8 (1971) 6−5 1/8 (1958) 4078 4878 5678 6078 6478
6−11 3/8 (2117) 6−11 5/8 (2124) 6−11 1/8 (2111) 4084 4884 5684 6084 6484
7−7 3/8 (2320) 7−7 5/8 (2327) 7−7 1/8 (2314) 4092 4892 5692 6092 6492
7−11 3/8 (2422) 7−11 5/8 (2428) 7−11 1/8 (2416) 4096 4896 5696 6096 6496
= standard size − operator, stationary
= not available
For safety and/or code requirements, Marvin recommends tempered glass in all units with a Frame Size height of71 1/8� or larger.
Units with Frame Size 25.2 sq. ft. and larger may require tempered glass.
FS = Fame SizeRO = Rough OpeningMO = Masonry OpeningCN = Call NumberOM = Outside Measurement
CLAD ULTIMATE CASEMENT PICTURE
Standard Sizes − 3/4″ IG Picture CUCAP and CUPCAP
1A.2811708324
Marvin Architectural Detail Manual2012−01−23
Clad Ultimate Casement PictureFull Frame Standard Sizes − 3/4” IG
Stationary/Picture
Width
MO 6−0 1/2 (1842) 6−8 1/2 (2045) 7−4 1/2 (2248) 8−0 1/2 (2451)
RO 6−1 (1854) 6−9 (2057) 7−5 (2261) 8−1 (2464)
Height FS 6−0 (1829) 6−8 (2032) 7−4 (2235) 8−0 (2438)
MO RO FS Call Number
0−11 3/8 (289) 0−11 5/8 (295) 0−11 1/8 (283) 7212 8012 8812 9612
1−1 3/8 (339) 1−1 5/8 (346) 1−1 1/8 (333) 7214 8014 8814 9614
1−3 3/8 (390) 1−3 5/8 (396) 1−3 1/8 (384) 7216 8016 8816 9616
1−5 3/8 (441) 1−5 5/8 (447) 1−5 1/8 (434) 7218 8018 8818 9618
1−7 3/8 (492) 1−7 5/8 (498) 1−7 1/8 (485) 7220 8020 8820 9620
1−11 3/8 (593) 1−11 5/8 (600) 1−11 1/8 (587) 7224 8024 8824 9624
2−3 3/8 (695) 2−3 5/8 (701) 2−3 1/8 (688) 7228 8028 8828 9628
2−7 3/8 (796) 2−7 5/8 (803) 2−7 1/8 (790) 7232 8032 8832 9632
2−11 3/8 (898) 2−11 5/8 (904) 2−11 1/8 (892) 7236 8036 8836 9636
3−3 3/8 (1000) 3−3 5/8 (1006) 3−3 1/8 (993) 7240 8040 8840 9640
3−7 3/8 (1101) 3−7 5/8 (1108) 3−7 1/8 (1095) 7244 8044 8844 9644
3−11 3/8 (1203) 3−11 5/8 (1209) 3−11 1/8 (1196) 7248 8048 8848 9648
4−5 3/8 (1355) 4−5 5/8 (1362) 4−5 1/8 (1349) 7254 8054 8854 9654
4−7 3/8 (1406) 4−7 5/8 (1412) 4−7 1/8 (1400) 7256 8056 8856 9656
4−11 3/8 (1508) 4−11 5/8 (1514) 4−11 1/8 (1501) 7260 8060 8860 9660
5−3 3/8 (1609) 5−3 5/8 (1616) 5−3 1/8 (1603) 7264 8064 8864 9664
5−11 3/8 (1812) 5−11 5/8 (1819) 5−11 1/8 (1806) N/A N/A N/A N/A
6−5 3/8 (1965) 6−5 5/8 (1971) 6−5 1/8 (1958) N/A N/A N/A N/A
6−11 3/8 (2117) 6−11 5/8 (2124) 6−11 1/8 (2111) N/A N/A N/A N/A
7−7 3/8 (2320) 7−7 5/8 (2327) 7−7 1/8 (2314) N/A N/A N/A N/A
7−11 3/8 (2422) 7−11 5/8 (2428) 7−11 1/8 (2416) N/A N/A N/A N/A
= standard size − operator, stationary
= not available
For safety and/or code requirements, Marvin recommends tempered glass in all units with a Frame Size height of71 1/8� or larger.
Units with Frame Size 25.2 sq. ft. and larger may require tempered glass.
FS = Fame SizeRO = Rough OpeningMO = Masonry OpeningCN = Call NumberOM = Outside Measurement
CLAD ULTIMATE CASEMENT / PUSH OUT PICTURE
Standard Sizes − 3/4″ IG Picture CUCAP and CUPCAP
1A.2911708324
Marvin Architectural Detail Manual2012−01−23
Clad Ultimate Casement PictureFull Frame Standard Sizes − 1� IG
Stationary/Picture
Width
MO 3−4 1/2 (1028) 4−0 1/2 (469) 4−8 1/2 (1435) 5−0 1/2 (1537) 5−4 1/2 (1638)
RO 3−5 (1041) 4−1 (1245) 4−9 (1448) 5−1 (1549) 5−5 (1651)
Height FS 3−4 (1016) 4−0 (1219) 4−8 (1422) 5−0 (1524) 5−4 (1626)
MO RO FS Call Number
0−11 3/8 (289) 0−11 5/8 (295) 0−11 1/8 (283) 4012 4812 5612 6012 6412
1−1 3/8 (339) 1−1 5/8 (346) 1−1 1/8 (333) 4014 4814 5614 6014 6414
1−3 3/8 (390) 1−3 5/8 (396) 1−3 1/8 (384) 4016 4816 5616 6016 6416
1−5 3/8 (441) 1−5 5/8 (447) 1−5 1/8 (434) 4018 4818 5618 6018 6418
1−7 3/8 (492) 1−7 5/8 (498) 1−7 1/8 (485) 4020 4820 5620 6020 6420
1−11 3/8 (593) 1−11 5/8 (600) 1−11 1/8 (587) 4024 4824 5624 6024 6424
2−3 3/8 (695) 2−3 5/8 (701) 2−3 1/8 (688) 4028 4828 5628 6028 6428
2−7 3/8 (796) 2−7 5/8 (803) 2−7 1/8 (790) 4032 4832 5632 6032 6432
2−11 3/8 (898) 2−11 5/8 (904) 2−11 1/8 (892) 4036 4836 5636 6036 6436
3−3 3/8 (1000) 3−3 5/8 (1006) 3−3 1/8 (993) 4040 4840 5640 6040 6440
3−7 3/8 (1101) 3−7 5/8 (1108) 3−7 1/8 (1095) 4044 4844 5644 6044 6444
3−11 3/8 (1203) 3−11 5/8 (1209) 3−11 1/8 (1196) 4048 4848 5648 6048 6448
4−5 3/8 (1355) 4−5 5/8 (1362) 4−5 1/8 (1349) 4054 4854 5654 6054 6454
4−7 3/8 (1406) 4−7 5/8 (1412) 4−7 1/8 (1400) 4056 4856 5656 6056 6456
4−11 3/8 (1508) 4−11 5/8 (1514) 4−11 1/8 (1501) 4060 4860 5660 6060 6460
5−3 3/8 (1609) 5−3 5/8 (1616) 5−3 1/8 (1603) 4064 4864 5664 6064 6464
5−11 3/8 (1812) 5−11 5/8 (1819) 5−11 1/8 (1806) 4072 4872 5672 6072 6472
6−5 3/8 (1965) 6−5 5/8 (1971) 6−5 1/8 (1958) 4078 4878 5678 6078 6478
6−11 3/8 (2117) 6−11 5/8 (2124) 6−11 1/8 (2111) 4084 4884 5684 6084 6484
7−7 3/8 (2320) 7−7 5/8 (2327) 7−7 1/8 (2314) 4092 4892 5692 6092 6492
7−11 3/8 (2422) 7−11 5/8 (2428) 7−11 1/8 (2416) 4096 4896 5696 6096 6496
= standard size − operator, stationary
= not available
For safety and/or code requirements, Marvin recommends tempered glass in all units with a Frame Size height of71 1/8� or larger.
Units with Frame Size 25.2 sq. ft. and larger may require tempered glass.
FS = Fame SizeRO = Rough OpeningMO = Masonry OpeningCN = Call NumberOM = Outside Measurement
CLAD ULTIMATE CASEMENT PICTURE
Standard Sizes − 1″ IG Picture CUCAP and CUPCAP
1A.3011708324
Marvin Architectural Detail Manual2012−01−23
Clad Ultimate Casement PictureFull Frame Standard Sizes − 1� IG
Stationary/Picture
Width
MO 6−0 1/2 (1842) 6−8 1/2 (2045) 7−4 1/2 (2248) 8−0 1/2 (2451)
RO 6−1 (1854) 6−9 (2057) 7−5 (2261) 8−1 (2464)
Height FS 6−0 (1829) 6−8 (2032) 7−4 (2235) 8−0 (2438)
MO RO FS Call Number
0−11 3/8 (289) 0−11 5/8 (295) 0−11 1/8 (283) 7212 8012 8812 9612
1−1 3/8 (339) 1−1 5/8 (346) 1−1 1/8 (333) 7214 8014 8814 9614
1−3 3/8 (390) 1−3 5/8 (396) 1−3 1/8 (384) 7216 8016 8816 9616
1−5 3/8 (441) 1−5 5/8 (447) 1−5 1/8 (434) 7218 8018 8818 9618
1−7 3/8 (492) 1−7 5/8 (498) 1−7 1/8 (485) 7220 8020 8820 9620
1−11 3/8 (593) 1−11 5/8 (600) 1−11 1/8 (587) 7224 8024 8824 9624
2−3 3/8 (695) 2−3 5/8 (701) 2−3 1/8 (688) 7228 8028 8828 9628
2−7 3/8 (796) 2−7 5/8 (803) 2−7 1/8 (790) 7232 8032 8832 9632
2−11 3/8 (898) 2−11 5/8 (904) 2−11 1/8 (892) 7236 8036 8836 9636
3−3 3/8 (1000) 3−3 5/8 (1006) 3−3 1/8 (993) 7240 8040 8840 9640
3−7 3/8 (1101) 3−7 5/8 (1108) 3−7 1/8 (1095) 7244 8044 8844 9644
3−11 3/8 (1203) 3−11 5/8 (1209) 3−11 1/8 (1196) 7248 8048 8848 9648
4−5 3/8 (1355) 4−5 5/8 (1362) 4−5 1/8 (1349) 7254 8054 8854 9654
4−7 3/8 (1406) 4−7 5/8 (1412) 4−7 1/8 (1400) 7256 8056 8856 9656
4−11 3/8 (1508) 4−11 5/8 (1514) 4−11 1/8 (1501) 7260 8060 8860 9660
5−3 3/8 (1609) 5−3 5/8 (1616) 5−3 1/8 (1603) 7264 8064 8864 9664
5−11 3/8 (1812) 5−11 5/8 (1819) 5−11 1/8 (1806) 7272 8072 8872 9672
6−5 3/8 (1965) 6−5 5/8 (1971) 6−5 1/8 (1958) 7278 8078 8878 9678
6−11 3/8 (2117) 6−11 5/8 (2124) 6−11 1/8 (2111) 7284 8084 8884 9684
7−7 3/8 (2320) 7−7 5/8 (2327) 7−7 1/8 (2314) 7292 8092 8892 N/A
7−11 3/8 (2422) 7−11 5/8 (2428) 7−11 1/8 (2416) 7296 8096 8896 N/A
= standard size − operator, stationary
= not available
For safety and/or code requirements, Marvin recommends tempered glass in all units with a Frame Size height of71 1/8� or larger.
Units with Frame Size 25.2 sq. ft. and larger may require tempered glass.
FS = Fame SizeRO = Rough OpeningMO = Masonry OpeningCN = Call NumberOM = Outside Measurement
CLAD ULTIMATE CASEMENT / PUSH OUT PICTURE
Standard Sizes − 1″ IG Picture CUCAP and CUPCAP
Head Jamb and Sill Jamb
5 21/32″(144)
4 9/16″(116)
1 3/16″(30)
Operating − 3/4� IG
Rou
ghO
peni
ng
Mas
onry
Ope
ning
Day
light
Ope
ning
RoughOpening
MasonryOpening
DaylightOpening
Fra
me
Siz
e
FrameSize
1/2″(13)
1/4″(6)
2 3/32″(53)
5 21/32″(144)
4 9/16″(116)
1/2″(13)
1/4″(6)
1 3/16″(30)
2 29/32″(74)
2 3/32″(53)
1 3/16″(30)
1 3/16″(30)
1/2″(13)
1/4″(6)
2 3/32″(53)
2 3/32″(53)
Stationary/Picture − 3/4� IG
Head Jamb and Sill Jamb
5 21/32″(144)
4 9/16″(116)
1 3/16″(30)
Rou
ghO
peni
ng
Mas
onry
Ope
ning
Day
light
Ope
ning
Fra
me
Siz
e
1/2″(13)
1/4″(6)
2 3/32″(53)
1 3/16″(30)
2 29/32″(74)
2 3/32″(53)
2 29/32″(74)
2 29/32″(74)
2 29/32″(74)
2 29/32″(74)
RoughOpening
MasonryOpening
DaylightOpening
FrameSize
5 21/32″(144)
4 9/16″(116)
1/2″(13)
1/4″(6)
1 3/16″(30)
1 3/16″(30)
1/2″(13)
1/4″(6)
2 3/32″(53)
2 3/32″(53)
2 29/32″(74)
2 29/32″(74)
1A.3111708324
Marvin Architectural Detail Manual2011−08−23
CLAD ULTIMATE CASEMENT
SECTION DETAILS: 3/4″ − OPERATING/STATIONARY/PICTURESCALE: 3� = 1� 0�
Operating − 1� IG
Head Jamb and Sill Jamb
5 21/32″(144)
4 9/16″(116)
1 3/16″(30)
Rou
ghO
peni
ng
Mas
onry
Ope
ning
Day
light
Ope
ning
RoughOpening
MasonryOpening
DaylightOpening
Fra
me
Siz
e
FrameSize
1/2″(13)
1/4″(6)
2 3/32″(53)
5 21/32″(144)
4 9/16″(116)
1/2″(13)
1/4″(6)
1 3/16″(30)
2 29/32″(74)
2 3/32″(53)
1 3/16″(30)
1 3/16″(30)
1/2″(13)
1/4″(6)
2 3/32″(53)
2 3/32″(53)
Stationary/Picture − 1� IG
Head Jamb and Sill Jamb
5 21/32″(144)
4 9/16″(116)
1 3/16″(30)
Rou
ghO
peni
ng
Mas
onry
Ope
ning
Day
light
Ope
ning
RoughOpening
MasonryOpening
DaylightOpening
Fra
me
Siz
e
FrameSize
1/2″(13)
1/4″(6)
2 3/32″(53)
5 21/32″(144)
4 9/16″(116)
1/2″(13)
1/4″(6)
1 3/16″(30)
2 3/32″(53)
1 3/16″(30)
1 3/16″(30)
1/2″(13)
1/4″(6)
2 3/32″(53)
2 3/32″(52)
2 29/32″(74)
2 29/32″(74)
2 29/32″(74)
2 29/32″(74)
2 29/32″(74)
2 29/32″(74)
2 29/32″(74)
1A.3211708324
Marvin Architectural Detail Manual2011−08−23
CLAD ULTIMATE CASEMENT
SECTION DETAILS: 1″ − OPERATING/STATIONARY/PICTURESCALE: 3� = 1� 0�
Clad BMC w/ 6 9/16� Jambs
Flat Casing
Head Jamb and Sill
Head Jamb and Sill Head Jamb and Sillshown with Wood Screen installed
6 9/16″(167)
1 3/16″(30)
1/4″(6)
1/2″(13)
1 3/16″(30)
21/32″(17)
5/8″(16)
1 5/16″(33)
1 3/16″(30)
Rou
ghO
peni
ng
Fra
me
Siz
e
Mas
onry
Ope
ning
Rou
ghO
peni
ng
Fra
me
Siz
e
Mas
onry
Ope
ning
1/4″(6) 1 3/32″
(28)
1/2″(13)
21/32″(17)
1 3/16″(30)
5/8″(16)
6 9/16″(167)
7 21/32″(194)
1/2″(13)
Rou
ghO
peni
ng
Fra
me
Siz
e
Mas
onry
Ope
ning
1/4″(6)
Wood Screen
OperatorTall Bottom Rail
4 3/8″(111)
3 19/32″(91)
StationaryTall Bottom Rail
4 3/8″(111)
3 19/32″(91)
21/32″(17)
21/32″(17)
1 3/16″(30)
21/32″(17)
1A.3311708324
Marvin Architectural Detail Manual2011−08−23
CLAD ULTIMATE CASEMENT
SECTION DETAILS: CASINGS, SUBSILL, WOOD SCREEN, 6 9/16″ JAMBSSCALE: 3� = 1� 0�
Head Jamb and Sill
Operating CUCAwith Retractable Screen
Jamb − Screen Open Jamb − Screen Closed
1 3/16″
(30)
4 9/16″(116)
5 21/32″(144)
1 3/16″(30)
4 9/16″(116)
5 21/32″(144)
1 3/16″
(30)1 3/16″
(30)
2 29/32″(74)
2 29/32″(74)
2 29/32″
(74)
4 9/16″(116)
5 21/32″(144)
1 3/16″
(30)1 3/16″
(30)
2 29/32″(74)
2 29/32″
(74)
1A.3411708324
Marvin Architectural Detail Manual2012−04−30
CLAD ULTIMATE CASEMENT
SECTION DETAILS: RETRACTABLE SCREENSCALE: 3� = 1� 0�
Head Jamb and Sill Jamb
5 21/32″(144)
4 9/16″(116)
1 3/16″(30)
Operating − 3/4� IG
Rou
ghO
peni
ng
Mas
onry
Ope
ning
Day
light
Ope
ning
RoughOpening
MasonryOpening
DaylightOpening
Fra
me
Siz
e
FrameSize
1/2″(13) 1/4″
(6)
2 3/32″(53)
5 21/32″(144)
4 9/16″(116)
1/2″(13)
1/4″(6)
1 3/16″(30)
2 29/32″(74)
2 3/32″(53)
1 3/16″(30)
1 3/16″(30)
1/2″(13)
1/4″(6)
2 3/32″(53)
2 3/32″(53)
Stationary/Picture − 3/4� IG
Head Jamb and Sill Jamb
5 21/32″(144)
4 9/16″(116)
1 3/16″(30)
Rou
ghO
peni
ng
Mas
onry
Ope
ning
Day
light
Ope
ning
RoughOpening
MasonryOpening
DaylightOpening
Fra
me
Siz
e
FrameSize
1/2″(13)
1/4″(6)
2 3/32″(53) 5 21/32″
(144)
4 9/16″(116)
1/2″(13)
1/4″(6)
1 3/16″(30)
2 3/32″(53)
1 3/16″(30)
1 3/16″(30)
1/2″(13)
1/4″(6)
2 3/32″(53)
2 3/32″(53)
2 29/32″(74)
2 29/32″(74)
2 29/32″(74)
2 29/32″(74)
2 29/32″(74)
2 29/32″(74)
2 29/32″(74)
1A.3511708324
Marvin Architectural Detail Manual2011−08−23
CLAD ULTIMATE PUSH OUT CASEMENT
SECTION DETAILS: 3/4″ OPERATING/STATIONARY/PICTURESCALE: 3� = 1� 0�
Operating − 1� IG
Head Jamb and Sill Jamb
5 21/32″(144)
4 9/16″(116)
1 3/16″(30)
Rou
ghO
peni
ng
Mas
onry
Ope
ning
Day
light
Ope
ning
RoughOpening
MasonryOpening
DaylightOpening
Fra
me
Siz
e
FrameSize
1/2″(13)
1/4″(6)
2 3/32″(53)
5 21/32″(144)
4 9/16″(116)
1/2″(13)
1/4″(6)
1 3/16″(30)
2 29/32″(74)
2 3/32″(53)
1 3/16″(30)
1 3/16″(30)
1/2″(13)
1/4″(6)
2 3/32″(53)
2 3/32″(53)
Stationary/Picture − 1� IG
Head Jamb and Sill Jamb
5 21/32″(144)
4 9/16″(116)
1 3/16″(30)
Rou
ghO
peni
ng
Mas
onry
Ope
ning
Day
light
Ope
ning
RoughOpening
MasonryOpening
DaylightOpening
Fra
me
Siz
e
FrameSize
1/2″(13)
1/4″(6)
2 3/32″(53)
5 21/32″(144)
4 9/16″(116)
1/2″(13)
1/4″(6)
1 3/16″(30)
2 3/32″(53)
1 3/16″(30)
1 3/16″(30)
1/2″(13)
1/4″(6)
2 3/32″(53)
2 3/32″(53)
2 29/32″(74)
2 29/32″(74)
2 29/32″(74)
2 29/32″(74)
2 29/32″(74)
2 29/32″(74) 2 29/32″
(74)
1A.3611708324
Marvin Architectural Detail Manual2011−08−23
CLAD ULTIMATE PUSH OUT CASEMENT
SECTION DETAILS: 1″ − OPERATING/STATIONARY/PICTURESCALE: 3� = 1� 0�
Head Jamb and Sill
Operating CUPCAwith Retractable Screen
Jamb − Screen Open
1 3/16″
(30)
4 9/16″(116)
1 3/16″(30)
4 9/16″
(116)
2 29/32″(74)
1 3/16″
(30)1 3/16″
(30)
2 29/32″(74)
2 29/32″
(74)
2 29/32″
(73)
5 21/32″(143)
5 21/32″(144)
1A.3711708324
Marvin Architectural Detail Manual2012−04−30
CLAD ULTIMATE PUSH OUT CASEMENT
SECTION DETAILS: RETRACTABLE SCREENSCALE: 3� = 1� 0�
Clad BMC
Flat Casing
Head Jamb and Sill − Operator
Head Jamb and Sill − Stationary
6 9/16″(167)
1 3/16″(30)
1/4″(6)
1/2″(13)
1 3/16″(30)
21/32″(17)
5/8″(15)
1 5/16″(33)
1 3/16″(30)
Rou
ghO
peni
ng
Fra
me
Siz
e
Mas
onry
Ope
ning
Mas
onry
Ope
ning
1/4″(6)
1 3/32″(28)
5/8″(15)
OperatorTall Bottom Rail
4 3/8″(111)
3 19/32″(91)
StationaryTall Bottom Rail
4 3/8″(111)
3 19/32″(91)
1 3/16″(30)
21/32″(17)
1/2″(13)
Rou
ghO
peni
ng
Fra
me
Siz
e
3″(76)
1 3/16″(30)
1A.3811708324
Marvin Architectural Detail Manual2011−12−19
CLAD ULTIMATE PUSH OUT CASEMENT
SECTION DETAILS: CASINGS, 6 9/16″ JAMBSSCALE: 3� = 1� 0�
LVL Span 72″3/8″ MRF Span 78″
Max TW 60″
1A.3911708324
Marvin Architectural Detail Manual2011−02−28
MULLING
Factory Mulling available − The Ultimate Casement may be mulled to existing Marvin products.� Standard mull limits (all factory mulls)
Maximum Mulled Assembly Total SizeMasonry opening 120.000″ x 103.000″
Maximum Mulled Assembly Total Area� Maximum masonry opening area is 48 ft^2� Weight limitation of assembly for handling purposes (Approximately 150.000 lbs)
Certified Mull Limits: WDMA Hallmark certified to AAMA 450.� Multi−wide Multi−high mulls with 3/8″ Mull Reinforcement. Max span is 78″. Max tributary with is 60″. Max assembly size for vertical
reinforcement is 120″ x 78″. Max assembly size for horizontal reinforcement is 78″ x 120″. Certified to DP65.� If assemblies have individual units that have a lower design pressure than the mull; the entire assembly is rated at the lower design
pressure.� Items not included in certified mulls: space mulls, stud pockets, non−reinforced multi−high multi−wide assemblies, assemblies without
continuous header or sills.
1 Directional Mull Limits
Product Max Span Max TW Max Overall Size DPClad Ultimate Casement* 83 1/8″ (2111) 60″ (1524) 120″x83 1/8″ OR 83 1/8″x120″ 50
Clad Ultimate Casement IZ3* 83 1/8″ (2111) 54″ (1372) 108″x83 1/8″ OR 83 1/8″x108″ 65
* Frame to Frame or 1″ LVL or 3/8″ MRF
NOTES:1. Limited to 1H or 1W only2. Includes CUCA operators, and Push Out products3. Assembly DP is lowest DP of mull or any product4. Stepped Mulls are not certified.5. TW = 1/2A + 1/2B6. Space Mull and Stud Pockets are not certified7. 1 Directional mulls with 3/8″ MRF or LVL are certified to these limits
2 Wide 2 High Directional Mull Limits
� Applies to all Clad UCA Full Frame products only� Max assembly size for LVL is 120″x72″ or 72″x120″� Max assembly size for 3/8″ MRF is 120″x78″ or 78″x120″� Up to 6W6H� Max TW is 60 for LVL and 3/8″ MRF� LVL Max span is 72″� 3/8″ MRF Max span is 78″� No Space Mull or Stud Pockets allowed in the assembly� No non−reinforced mull joints (1 direction must be reinforced)� Reinforcement is continuous across shorter dimension, if neither
direction of the assembly exceeds the tested span, then reinforcementcan be run in either direction.
CLAD ULTIMATE CASEMENT/PUSH OUT CASEMENT
MULLING GUIDELINES
Horizontal Mullion − Picture/Operator
Vertical Mullion − w/4� Space Mull
6 3/8″(162)
1 1/16″(27)
5 13/16″(148)
2 3/8″(60)
1 1/16″(27)
4″(102)
2 3/8″(60)
1 5/16″(33)
9 13/16″(249)
5 5/16″(134)
Vertical Mullion − Operator/Operator/Direct Mull
1 5/16″(33)
5 13/16″(148)
2 3/8″(60)
1 1/16″(27)
1 5/16″(33)
Vertical Mullion − Operator/Picture/Direct Mull
5 13/16″(148)
3 3/8″(86)
2 1/8″(54)
2 5/16″(59)
Vertical Mullion − LVL
6 13/16″(173)
Horizontal Mullion − LVL
2 1/8″(54)
6 13/16″(173)
3 3/8″(86)
2 5/16″(59)
Operator/Operator
Operator/Operator Operator/Operator
1A.4011708324
Marvin Architectural Detail Manual2011−12−19
CLAD ULTIMATE CASEMENT
MULLIONSCALE: 3� = 1� 0�
Horizontal Mullion − Picture/Operator
Vertical Mullion − w/4� Space MullOperator/Operator
6 3/8″(162)
1 1/16″(27)
5 13/16″(147)
2 3/8″(60)
1 1/16″(27)
4″(102)
2 3/8″(60)
1 5/16″(33)
9 13/16″(249)
5 9/32″(134)
Vertical Mullion − Operator/Operator/Direct Mull
1 5/16″(33)
5 25/32″(147)
2 3/8″(60)
1 1/16″(27)
1 5/16″(33)
Vertical Mullion − Operator/Picture/Direct Mull
5 25/32″(147)
3 13/32″(86)
2 1/8″(54)
2 5/16″(59)
Vertical Mullion − LVLOperator/Operator
6 13/16″(173)
Horizontal Mullion − LVLOperator/Operator
2 1/8″(54)
6 13/16″(173)
3 13/32″(86)
2 5/16″(59)
1A.4111708324
Marvin Architectural Detail Manual2011−12−19
CLAD ULTIMATE PUSH OUT CASEMENT
MULLIONSCALE: 3� = 1� 0�
For CUCA/CUPCA and CUPCAP/CUCAP(CUCA shown)
NOTE:Grille = Removable interior dividerSDL = Simulated divided liteGBG = Grilles between glass
Insulating Glass 3/4� Grille
7/8� SDLwithout Spacer Bar
7/8� SDLwith Spacer Bar
1 1/8� Grille
1 1/8� SDLwithout Spacer Bar
1 1/8� SDLwith Spacer Bar
Aluminum11/16� Contour GBG
3/4″(19)
1 1/8″(29)
1 1/8″(29)
1 1/8″(29)
7/8″(22)
7/8″(22)
11/16″(17)
5/8� SDLwithout Spacer Bar
1 3/4� SDLwith Spacer Bar
2 13/32� SDLwithout Spacer Bar
1 3/4� SDLwithout Spacer Bar
2 13/32� SDLwith Spacer Bar
5/8″(16)
1 3/4″(44)
2 13/32″(61)
1 3/4″(44)
2 13/32″(61)
5/8� SDLwith Spacer Bar
5/8″(16)
1 3/4� SDLwith Two Spacer Bars
1 3/4″(44)
2 13/32� SDLwith Two Spacer Bars
2 13/32″(61)
1A.4211708324
Marvin Architectural Detail Manual2011−10−24
CLAD ULTIMATE CASEMENT/ PUSH OUT PICTURE
DIVIDED LITE OPTIONSNOT TO SCALE