sinacon pv central inverter - gtg-india.com

20
SINACON PV Central Inverter Knowledge Session on Technical Advancements in RE (Solar) Interfacing Inverters, July 30, 2018 siemens.com © Siemens AG 2017

Upload: others

Post on 24-Nov-2021

11 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SINACON PV Central Inverter - gtg-india.com

SINACON PV

Central InverterKnowledge Session on Technical Advancements in RE (Solar)

Interfacing Inverters,

July 30, 2018

siemens.com© Siemens AG 2017

Page 2: SINACON PV Central Inverter - gtg-india.com

© Siemens AG 2018

Jul 30th, 2018Page 2 Bidyut Mazumder / EM MS PA PV

The Energy Revolution: Big Picture

Distributed Energy Systems

Distribution and ConsumptionTransmission

From centralized power

and unidirectional grid …

… to fully integrated & intelligent

Central and Distributed Energy

Systems and bidirectional

balancing

Distance from

source to load

Refurbishment/

upgrades

Decentralization

(public/private)

Changing

generation mix

Generation

capacity

additions

3 5421

Page 3: SINACON PV Central Inverter - gtg-india.com

© Siemens AG 2018

Jul 30th, 2018Page 3 Bidyut Mazumder / EM MS PA PV

Big data

has to be

turned into

smart data

Distributed

Energy

Systems

increase

complexity

Capacity

constrains

require fast

reacting grid

control and

adaptive

assets

Customer

behavior

Dependency

relationships

dissolve

The energy business is changing dramatically

Shorter

market time

intervals

make asset

management

more difficult

Frequency

and voltage

stability

challenges

More load

swings need

to be

managed

Page 4: SINACON PV Central Inverter - gtg-india.com

© Siemens AG 2018

Jul 30th, 2018Page 4 Bidyut Mazumder / EM MS PA PV

Invests in energy production until 2040 worldwide

Source: Bloomberg and S&P Capital IQ

Page 5: SINACON PV Central Inverter - gtg-india.com

© Siemens AG 2018

Jul 30th, 2018Page 5 Bidyut Mazumder / EM MS PA PV

Global solar energy yield and the solar belthttps://en.wikipedia.org/wiki/Photovoltaic_system#/media/File:SolarGIS-Solar-map-World-map-en.png

India> 5 kWh/m²

Page 6: SINACON PV Central Inverter - gtg-india.com

© Siemens AG 2018

Jul 30th, 2018Page 6 Bidyut Mazumder / EM MS PA PV

Siemens PV focus:

Electrical Balance of Plant (eBoP)

=~

Page 7: SINACON PV Central Inverter - gtg-india.com

© Siemens AG 2018

Jul 30th, 2018Page 7 Bidyut Mazumder / EM MS PA PV

Medium Voltage Inverter Station

up to 5 MVA at 1500 VDC

Siemens SINACON PV now available

Page 8: SINACON PV Central Inverter - gtg-india.com

© Siemens AG 2018

Jul 30th, 2018Page 8 Bidyut Mazumder / EM MS PA PV

SINACON PV Inverter

up to 5 MVA at 1500 VDC

Page 9: SINACON PV Central Inverter - gtg-india.com

© Siemens AG 2018

Jul 30th, 2018Page 9 Bidyut Mazumder / EM MS PA PV

Medium Voltage Inverter Station

Water Cooling System

RMU MV-Transformer SINACON PV Inverter

Page 10: SINACON PV Central Inverter - gtg-india.com

© Siemens AG 2018

Jul 30th, 2018Page 10 Bidyut Mazumder / EM MS PA PV

SINACON PV Inverter

Better Derating

Made for harsh environments:

Most utility scale projects are in “solar belts”

Dessert areas with extreme temperatures

Tropical climates with highest humidity

Installations close the coastHigher Energy Output:

Later derating at higher

ambient temperature

More energy harvest at

higher altitude

Effective also with high

ambient humidity

Page 11: SINACON PV Central Inverter - gtg-india.com

© Siemens AG 2018

Jul 30th, 2018Page 11 Bidyut Mazumder / EM MS PA PV

SINCAON PV Inverter

Designed for harsh environments

The SINACON PV inverter is used in medium and large PV plants. In order to achieve high

profits, the SINACON PV inverter is equipped with 3-level IGBT modules for input

voltages of up to DC 1500 V and thus optimized for high efficiency.

The integrated DC and AC distribution makes the SINACON PV inverter cost efficient.

Standardized interface for easy plug and play reduce engineering hours.

Unique Selling Points:

Designed for harsh environments

IP 65

Maintenance free liquid cooling

Late derating

Extreme high quality according to Siemens standards

SFS financing

Service trainings by Siemens Fürth

Page 12: SINACON PV Central Inverter - gtg-india.com

© Siemens AG 2018

Jul 30th, 2018Page 12 Bidyut Mazumder / EM MS PA PV

Grid Management of SINACON PV Inverters

The requirements of the grid security management can be met by parametrization of the

functions in the SINACON PV Inverter by :

- Remote Access via VNC

- Modbus TCP Interface

- Powerlink Interface

Connection Conditions can be set:

Static Grid Support available

Dynamic Grid Support available

Shutdown behaviour can be configured for voltage/ frequency dips / rises

Grid Voltage/ Frequency Monitoring available

Page 13: SINACON PV Central Inverter - gtg-india.com

© Siemens AG 2018

Jul 30th, 2018Page 13 Bidyut Mazumder / EM MS PA PV

Connection Conditions

Connection Conditions can be set (Eg):

> If Grid Voltage above UC0390 or below UC0400, grid disconnected

> If Grid Frequency above UC0410 or below UC0420, grid disconnected

Page 14: SINACON PV Central Inverter - gtg-india.com

© Siemens AG 2018

Jul 30th, 2018Page 14 Bidyut Mazumder / EM MS PA PV

Active Power Control in case of over-frequency (BDEW)

Page 15: SINACON PV Central Inverter - gtg-india.com

© Siemens AG 2018

Jul 30th, 2018Page 15 Bidyut Mazumder / EM MS PA PV

Dynamic Grid-Support on LVRT & HVRT

Page 16: SINACON PV Central Inverter - gtg-india.com

© Siemens AG 2018

Jul 30th, 2018Page 16 Bidyut Mazumder / EM MS PA PV

Correlation between FRT and Protective disconnection

Page 17: SINACON PV Central Inverter - gtg-india.com

© Siemens AG 2018

Jul 30th, 2018Page 17 Bidyut Mazumder / EM MS PA PV

Protective Disconnection - Frequency

Page 18: SINACON PV Central Inverter - gtg-india.com

© Siemens AG 2018

Jul 30th, 2018Page 18 Bidyut Mazumder / EM MS PA PV

Reactive Power Control w.r.t output voltage Q = f(U)

Page 19: SINACON PV Central Inverter - gtg-india.com

© Siemens AG 2018

Jul 30th, 2018Page 19 Bidyut Mazumder / EM MS PA PV

We have to leverage our collective

intelligence and curiosity!

Socrates:

“The secret of change is

to focus all of your energy,

not on fighting the old,

but on building the new”

Socrates (470 – 399 BC) was a Greek philosopher

Page 20: SINACON PV Central Inverter - gtg-india.com

© Siemens AG 2018

Jul 30th, 2018Page 20 Bidyut Mazumder / EM MS PA PV

Thank you for your Attention!