sinacon pv central inverter - gtg-india.com
TRANSCRIPT
SINACON PV
Central InverterKnowledge Session on Technical Advancements in RE (Solar)
Interfacing Inverters,
July 30, 2018
siemens.com© Siemens AG 2017
© Siemens AG 2018
Jul 30th, 2018Page 2 Bidyut Mazumder / EM MS PA PV
The Energy Revolution: Big Picture
Distributed Energy Systems
Distribution and ConsumptionTransmission
From centralized power
and unidirectional grid …
… to fully integrated & intelligent
Central and Distributed Energy
Systems and bidirectional
balancing
Distance from
source to load
Refurbishment/
upgrades
Decentralization
(public/private)
Changing
generation mix
Generation
capacity
additions
3 5421
© Siemens AG 2018
Jul 30th, 2018Page 3 Bidyut Mazumder / EM MS PA PV
Big data
has to be
turned into
smart data
Distributed
Energy
Systems
increase
complexity
Capacity
constrains
require fast
reacting grid
control and
adaptive
assets
Customer
behavior
Dependency
relationships
dissolve
The energy business is changing dramatically
Shorter
market time
intervals
make asset
management
more difficult
Frequency
and voltage
stability
challenges
More load
swings need
to be
managed
© Siemens AG 2018
Jul 30th, 2018Page 4 Bidyut Mazumder / EM MS PA PV
Invests in energy production until 2040 worldwide
Source: Bloomberg and S&P Capital IQ
© Siemens AG 2018
Jul 30th, 2018Page 5 Bidyut Mazumder / EM MS PA PV
Global solar energy yield and the solar belthttps://en.wikipedia.org/wiki/Photovoltaic_system#/media/File:SolarGIS-Solar-map-World-map-en.png
India> 5 kWh/m²
© Siemens AG 2018
Jul 30th, 2018Page 6 Bidyut Mazumder / EM MS PA PV
Siemens PV focus:
Electrical Balance of Plant (eBoP)
=~
© Siemens AG 2018
Jul 30th, 2018Page 7 Bidyut Mazumder / EM MS PA PV
Medium Voltage Inverter Station
up to 5 MVA at 1500 VDC
Siemens SINACON PV now available
© Siemens AG 2018
Jul 30th, 2018Page 8 Bidyut Mazumder / EM MS PA PV
SINACON PV Inverter
up to 5 MVA at 1500 VDC
© Siemens AG 2018
Jul 30th, 2018Page 9 Bidyut Mazumder / EM MS PA PV
Medium Voltage Inverter Station
Water Cooling System
RMU MV-Transformer SINACON PV Inverter
© Siemens AG 2018
Jul 30th, 2018Page 10 Bidyut Mazumder / EM MS PA PV
SINACON PV Inverter
Better Derating
Made for harsh environments:
Most utility scale projects are in “solar belts”
Dessert areas with extreme temperatures
Tropical climates with highest humidity
Installations close the coastHigher Energy Output:
Later derating at higher
ambient temperature
More energy harvest at
higher altitude
Effective also with high
ambient humidity
© Siemens AG 2018
Jul 30th, 2018Page 11 Bidyut Mazumder / EM MS PA PV
SINCAON PV Inverter
Designed for harsh environments
The SINACON PV inverter is used in medium and large PV plants. In order to achieve high
profits, the SINACON PV inverter is equipped with 3-level IGBT modules for input
voltages of up to DC 1500 V and thus optimized for high efficiency.
The integrated DC and AC distribution makes the SINACON PV inverter cost efficient.
Standardized interface for easy plug and play reduce engineering hours.
Unique Selling Points:
Designed for harsh environments
IP 65
Maintenance free liquid cooling
Late derating
Extreme high quality according to Siemens standards
SFS financing
Service trainings by Siemens Fürth
© Siemens AG 2018
Jul 30th, 2018Page 12 Bidyut Mazumder / EM MS PA PV
Grid Management of SINACON PV Inverters
The requirements of the grid security management can be met by parametrization of the
functions in the SINACON PV Inverter by :
- Remote Access via VNC
- Modbus TCP Interface
- Powerlink Interface
Connection Conditions can be set:
Static Grid Support available
Dynamic Grid Support available
Shutdown behaviour can be configured for voltage/ frequency dips / rises
Grid Voltage/ Frequency Monitoring available
© Siemens AG 2018
Jul 30th, 2018Page 13 Bidyut Mazumder / EM MS PA PV
Connection Conditions
Connection Conditions can be set (Eg):
> If Grid Voltage above UC0390 or below UC0400, grid disconnected
> If Grid Frequency above UC0410 or below UC0420, grid disconnected
© Siemens AG 2018
Jul 30th, 2018Page 14 Bidyut Mazumder / EM MS PA PV
Active Power Control in case of over-frequency (BDEW)
© Siemens AG 2018
Jul 30th, 2018Page 15 Bidyut Mazumder / EM MS PA PV
Dynamic Grid-Support on LVRT & HVRT
© Siemens AG 2018
Jul 30th, 2018Page 16 Bidyut Mazumder / EM MS PA PV
Correlation between FRT and Protective disconnection
© Siemens AG 2018
Jul 30th, 2018Page 17 Bidyut Mazumder / EM MS PA PV
Protective Disconnection - Frequency
© Siemens AG 2018
Jul 30th, 2018Page 18 Bidyut Mazumder / EM MS PA PV
Reactive Power Control w.r.t output voltage Q = f(U)
© Siemens AG 2018
Jul 30th, 2018Page 19 Bidyut Mazumder / EM MS PA PV
We have to leverage our collective
intelligence and curiosity!
Socrates:
“The secret of change is
to focus all of your energy,
not on fighting the old,
but on building the new”
Socrates (470 – 399 BC) was a Greek philosopher
© Siemens AG 2018
Jul 30th, 2018Page 20 Bidyut Mazumder / EM MS PA PV
Thank you for your Attention!