PRIMERGY RX300 S4 Server Options Guide Edition December 2007

Upload: phungphuc

Post on 27-Mar-2018

219 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

PRIMERGY RX300 S4Server Options Guide

Edition December 2007

Page 2: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

Comments… Suggestions… Corrections…The User Documentation Department would like toknow your opinion of this manual. Your feedback helpsus optimize our documentation to suit your individual needs.

Feel free to send us your comments by e-mail to [email protected].

Certified documentation according to DIN EN ISO 9001:2000To ensure a consistently high quality standard anduser-friendliness, this documentation was created tomeet the regulations of a quality management system which complies with the requirements of the standardDIN EN ISO 9001:2000.

cognitas. Gesellschaft für Technik-Dokumentation mbHwww.cognitas.de

Copyright and TrademarksCopyright © 2007 Fujitsu Siemens Computers GmbH.

All rights reserved.Delivery subject to availability; right of technical modifications reserved.

All hardware and software names used are trademarks of their respective manufacturers.

Page 3: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide

Contents

1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

1.1 Concept and target groups . . . . . . . . . . . . . . . . . . . 7

1.2 Documentation overview . . . . . . . . . . . . . . . . . . . . 7

1.3 Options and upgrade . . . . . . . . . . . . . . . . . . . . . . 9

1.4 Notational conventions . . . . . . . . . . . . . . . . . . . . 12

2 Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

3 Safety notes . . . . . . . . . . . . . . . . . . . . . . . . . . 15

4 Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

4.1 Removing the server form the rack . . . . . . . . . . . . . . 21

4.2 Opening the server . . . . . . . . . . . . . . . . . . . . . . . 22

4.3 Removing the air duct . . . . . . . . . . . . . . . . . . . . . 22

5 Main memory . . . . . . . . . . . . . . . . . . . . . . . . . . 25

5.1 Memory module population . . . . . . . . . . . . . . . . . . 25

5.2 Upgrading/replacing the main memory . . . . . . . . . . . . 26

6 Processors . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

6.1 Installing a second processor . . . . . . . . . . . . . . . . . 29

6.2 Replacing the processor . . . . . . . . . . . . . . . . . . . . 36

6.3 Replacing the processor heat sink . . . . . . . . . . . . . . 39

Page 4: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

Options Guide RX300 S4

Contents

7 Accessible drives . . . . . . . . . . . . . . . . . . . . . . . . 41

7.1 Installing a FD drive . . . . . . . . . . . . . . . . . . . . . . . 41

7.2 Installing a LocalView module . . . . . . . . . . . . . . . . . 46

7.3 Installing the optical disk drive . . . . . . . . . . . . . . . . . 51

7.4 USB tape drive / USB RDX drive . . . . . . . . . . . . . . . . 55

8 PCI slots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65

8.1 Installing a PCI controller . . . . . . . . . . . . . . . . . . . . 65

9 SAS controller . . . . . . . . . . . . . . . . . . . . . . . . . . 67

9.1 Upgrading a SAS controller . . . . . . . . . . . . . . . . . . . 67

10 Battery for PCI boards . . . . . . . . . . . . . . . . . . . . . 71

10.1 Installing the battery module for PCI boards . . . . . . . . . 71

11 External serial interface . . . . . . . . . . . . . . . . . . . . . 77

11.1 Installing the external serial interface . . . . . . . . . . . . . 77

12 External parallel interface . . . . . . . . . . . . . . . . . . . . 79

12.1 Installing an external parallel interface . . . . . . . . . . . . 79

13 Completion . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81

13.1 Inserting air duct . . . . . . . . . . . . . . . . . . . . . . . . 81

13.2 Closing the server . . . . . . . . . . . . . . . . . . . . . . . . 82

13.3 Installing the server into the rack . . . . . . . . . . . . . . . 82

Page 5: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide

Contents

14 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85

14.1 Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85

14.2 Configuration diagram . . . . . . . . . . . . . . . . . . . . . 91

Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93

Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99

Page 6: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a
Page 7: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 7

1 IntroductionThe PRIMERGY RX300 S4 server is an Intel-based server for mid-size networks and large companies. The server is suitable for use as a file server and also as an application, information or Internet server.

The PRIMERGY RX300 S4 server offers a high level of reliability and availability through highly developed hardware and software components. These include hot-plug hard disk drive modules, redundant CPU fans, system fans and power supply units, and PCI slots, the ServerView Suite server management software, „Prefailure Detection and Analysing“ (PDA) and „Automatic Server Reconfigu-ration and Restart“ (ASR&R).

Security functions in the BIOS Setup and on the system board protect the data on the server against manipulation. Additional security is provided by the lockable rack door.

1.1 Concept and target groups

This Options Guide shows you how you can expand and upgrade the server.

I The Operating Manual for the server describes how you install/remove the hot-plug components.

The activities described in this manual may only be performed by specialist personnel with technical training.

1.2 Documentation overview

I PRIMERGY manuals are available in PDF format on the ServerBooks DVD. The ServerBooks DVD is part of the ServerStart Suite supplied with every server.

The PDF files of the manuals can also be downloaded free of charge from the Internet. The overview page showing the online documentation available on the Internet can be found using the URL: http://manuals.fujitsu-siemens.com. The PRIMERGY server documentation can be accessed using the Industry standard servers navigation option.

Page 8: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

8 Options Guide RX300 S4

Documentation overview Introduction

If you need a replacement copy of the ServerBooks DVD, send the details of your server to the following e-mail address: [email protected]

More information on your PRIMERGY RX300 S4 can be found in the following documents:

– Quick Start Hardware - PRIMERGY RX300 S4 leaflet (only included as a printed copy)

– Quick Start Software - Quick Installation Guide leaflet (only included as a printed copy)

– Safety notes and other important information manual

– Warranty manual

– Customer Self Service (CSS) manual

– Ergonomics manual

– Returning used devices manual

– Helpdesk leaflet

– Technical manual for the system board D2519

– PRIMERGY RX300 S4 Server Operating Manual

– PRIMERGY RX300 S4 Server Options Guide

– Global Array Manager Client Software User’s Guide (PDF file available on the ServerBooks DVD supplied)

– Global Array Manager Server Software User’s Guide (PDF file available on the ServerBooks DVD supplied)

– Integrated Mirroring User’s Guide (PDF fil available on the ServerBooks DVD supplied)

Further sources of information:

– Manual for the monitor– Documentation for boards and drives– Documentation for your operating system– Information files on your operating system

Page 9: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 9

Introduction Options and upgrade

1.3 Options and upgrade

Second processor

The system board can be upgraded with a second processor. Only processors of the same type may be used on the system board. The second processor must have the same clock frequency and the same cache as the first processor.

Upgrading of the main memory

2x6 slots for main memory FBD PC2-4200 or FBD PC2-5300 fully buffered DIMM memory modules with 512 MB, 1 Gbyte, 2 Gbyte and 4 Gbyte (single rank).

Memory modules must always be incorporated in pairs.

The organization in six memory banks, 1, 2, 3, 5, 6 and 7 with 2 memory modules each, permits rapid memory access with four-way interleaving.

SAS RAID controller

The SAS RAID controller can be installed for operating internal hard disks. RAID levels 0, 1, 10, 5, 50, 6 and RAID 60 are supported..

SAS IME controller

The SAS-IME controller with Integrated Mirroring Enhanced functionality can be installed for operating internal hard disks. Integrated Mirroring Enhanced also provides RAID 0, 1, 1E functionality for configuring the internal hard disks.

Additional accessible drives

A number of mounting locations are available:

– one bay for a 3.5-inch slimline 1.44 MB floppy disk drive (optional) one LocalView module (optional) or a CSS-LED module (optional)

– one bay for a slimline optical drive (optional)

I The accessible drives integrated in these bays cannot be replaced during operation.

In a 6x3,5 or a 6x2,5 HDD configuration, a USB magnetic tape drive or an RDX drive can be installed in the left drive cage as an option. As a result, two bays are occupied in the drive cage.

Page 10: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

10 Options Guide RX300 S4

Options and upgrade Introduction

I – In a 6x3,5 HDD configuration these bays are then no longer available for HDD modules.

– The magnetic tape drive or the RDX drive cannot be replaced during operation.

LocalView module (alphanumeric system display)

The LocalView module provides you with the option of displaying system infor-mation and hardware system faults alphanumerically. This is an intelligent module with a micro-controller and its own memory, which functions indepen-dently of the server system.

The LocalView module consists of an LCD display panel and a toggle switch, both accommodated in a suitable mount. The mechanical mechanism used allows the LCD display panel to be pulled out and open. Further information on operating the display modes are provided in the documentation on the LocalView module.

Customer Self Service (CSS)

The Fujitsu Siemens Computers Customer Self Service (CSS) concept enables you to identify and replace the affected component yourself in the case of certain error scenarios.

In the CSS concept, you can replace the following components yourself in the event of an error:

– Hot-plug hard disk drives– Hot-plug power supply units– Hot-plug fans– Memory modules– Expansion cards

For information on replacing these components, see chapter „Hot-plug compo-nents of the operating manual or the Options Guide for your Primergy RX300 S4 on the ServerBooks DVD.

CSS indicators on the control panel and on the back of the PRIMERGY server provide you with information if a CSS event arises (for more information on the behavior of these indicators, see operating manual and the "Customer Self Service (CSS)" manual on the ServerBooks DVD). You can also fit your server with a CSS Module which enables you to identify the type of component affected by the error directly on the server (for more infor-mation, see the "Customer Self Service (CSS)" manual on the

Page 11: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 11

Introduction Options and upgrade

ServerBooks DVD). In addition, CSS errors are displayed in ServerView S2, the server management software from Fujitsu Siemens Computers. In the event of errors, ServerView S2 refers you directly to the affected component and its order information in the Illustrated Spares catalog of the server in question.

Hard disk drives

The server includes two drive cages for one of the following hard disk drive configurations:

– 3.5-inch SAS/SATA hard disk drives: up to six (2x3) hard disk drive (HDD) modules, each with a 3.5-inch SAS/SATA hard disk drive.

– 2.5-inch SAS hard disk drives: up to six (1x6) HDD modules, each with a 2.5-inch SAS hard disk drive.

– 2.5-inch SAS hard disk drives: up to twelve (2x6) HDD modules, each with a 2.5-inch SAS hard disk drive.

The module is connected to the SAS/SATA backplane without cables. This allows hard disk drive modules to be simply plugged in or pulled out (for further details see in chapter „Hot-plug components“ in the operating manual).

The hard disk subsystem is designed for SAS/SATA, each with one channel for each hard disk drive.

If the server has a RAID configuration, the HDD modules can be exchanged during operation (hot-swap).

I The three basic configurations are variants and can not be converted into an other variant in the field.

Additional controllers

The system board offers seven PCI slots. Slots 1, 2, 3, 5, 6 and 7 are PCI-e x4 slots. Slot 4 is a PCI slot with a PCI bus speed of 133MHz. If slot 2 or 5 are not occupied, slot 3 or 6 can be used octuple.

Additional Battery module

Optionally you can install an additional battery for use with a PCI controller.

Page 12: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

12 Options Guide RX300 S4

Notational conventions Introduction

External serial interface

The external serial interface can optionally be made available externally.

External parallel interface for printers

As an option, a parallel interface can be provided for printers.

1.4 Notational conventions

The following notational conventions are used in this manual:

Text in italics indicates commands, menu items or software programs.

„Quotation marks“ indicate names of chapters and terms that are being emphasized.

Ê describes activities that must be performed in the order shown.

V CAUTION! pay particular attention to texts marked with this symbol. Failure to observe this warning may endanger your life, destroy the system or lead to the loss of data.

I indicates additional information, notes and tips.

Table 1: Notational conventions

Page 13: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 13

2 ProcedureV CAUTION!

● The actions described in this manual should only be performed by technical specialists.

● Repairs to the device that do not relate to CSS failures must only be carried out by service personnel. Please note that unauthorized inter-ference with the system will void the warranty and exempt the manufacturer from all liability.

● Any failure to observe the guidelines in this manual, and any improper repairs could expose the user to risks (electric shock, energy hazards, fire hazards) or damage the equipment.

Ê First of all please familiarize yourself with the safety instructions in the chapter “Safety notes” on page 15.

Ê Ensure that all required manuals are available, printing out the PDF files if necessary. You will definitely need the Operating Manual for the server and the Technical Manual for the system board.

Ê Shut down the server correctly, switch it off, pull out the power plug, and open the server as described in the chapter “Preparation” on page 21.

Ê Extend or upgrade your server as described in the relevant chapter.

I The Operating Manual for the server describes how you install/remove the hot-plug components.

Ê Close the server, connect it to the power outlet.

Ê Switch it on as described in the chapter “Completion” on page 81

Ê Start the operating system and, if necessary, configure it as required (see the Operating Manual).

Page 14: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a
Page 15: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 15

Safety notes

3 Safety notesI The following safety notes are also provided in the “Safety notes and

other important information” manual.

This device complies with the relevant safety regulations for data processing equipment.

If you have any questions about where you can set up the device, contact your sales outlet or our customer service team.

V CAUTION!

● The actions described in this manual should only be performed by technical specialists.

● Repairs to the device that do not relate to CSS failures must only be carried out by service personnel. Please note that unauthorized inter-ference with the system will void the warranty and exempt the manufacturer from all liability.

● Any failure to observe the guidelines in this manual, and any improper repairs could expose the user to risks (electric shock, energy hazards, fire hazards) or damage the equipment.

Before operating the device

V CAUTION!

● During installation and before operating the device, observe the instructions on environmental conditions for your device.

● If the device is brought in from a cold environment, condensation may form both inside and on the outside of the machine.

Wait until the device has acclimatized to room temperature and is absolutely dry before starting it up. Material damage may be caused to the device if this requirement is not observed.

● Only transport the device in the original packaging or in packaging that protects it from knocks and jolts.

Page 16: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

16 Options Guide RX300 S4

Safety notes

Installation and operation

V CAUTION!

● If the rack model is integrated into an installation that receives power from an industrial (public) power supply network with the IEC309 connector, the (public) power supply protection must comply with the requirements for the non-industrial (public) power supply networks for the type A connector.

● The server automatically sets itself to a voltage in the range of 100 V to 240 V. Make sure that your local voltage is within this range.

● This device has a specially approved power cable and must only be connected to a grounded insulated socket.

● Ensure that the power socket on the device or the grounded wall outlet is freely accessible.

● The ON/OFF button does not disconnect the device from the mains voltage. To disconnect the line voltage completely, remove the power plug(s) from the grounded insulated socket(s).

● Always connect the device and the attached peripherals to the same power circuit. Otherwise you run the risk of losing data if, for example, the central processing unit is still running but the peripheral device (e.g. storage subsystem) has failed during a power outage.

● Data cables to peripheral devices must be adequately shielded.

● To the LAN wiring the requirements apply in accordance with the standards EN 50173 and EN 50174-1/2. As minimum requirement the use of a protected LAN line of category 5 for 10/100 MBps Ethernet, and/or of category 5e for Gigabit Ethernet is considered. The requirements of the specification ISO/IEC 11801 are to be considered.

● Route the cables in such a way that they do not form a potential hazard (make sure no-one can trip over them) and that they cannot be damaged. When connecting up a device, refer to the relevant notes in this manual.

● Never connect or disconnect data transmission lines during a storm (lightning hazard).

Page 17: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 17

Safety notes

● In emergencies (e.g. damaged casing, controls or cables, penetration of liquids or foreign matter), switch off the device immediately, remove the power plug(s) and contact your sales outlet or customer service team.

● Make sure that no objects (such as bracelets or paper clips) fall into or liquids spill into the device (risk of electric shock or short circuit).

● Proper operation of the device (in accordance with IEC 60950/EN 60950) is only ensured if the casing is completely assembled and the rear covers for the installation openings have been put in place (electric shock, cooling, fire protection, interference suppression).

● Only install system expansions that satisfy the requirements and rules governing safety and electromagnetic compatibility and relating to telecommunications terminal equipment. If you install other expan-sions, you may damage the system or violate the safety regulations and regulations governing RFI suppression. Information on which system expansions are suitable can be obtained from the customer service centre or your sales outlet.

● The components marked with a warning label (e.g. lightning symbol) may only be opened, removed or exchanged by authorized, qualified personnel. The hot-plug power supply units are exceptions to this rule.

● The warranty expires if the device is damaged during the installation or replacement of system expansions.

● You may only set those resolutions and refresh rates specified in the „Technical data“ section of the monitor description. Otherwise, you may damage your monitor. If you are in any doubt, contact your sales outlet or customer service centre.

Page 18: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

18 Options Guide RX300 S4

Safety notes

Batteries

V CAUTION!

● Incorrect replacement of batteries may lead to a risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer (see the technical manual for the system board D2519).

● Do not throw batteries into the trash can. They must be disposed of in accordance with local regulations concerning special waste.

● The battery must be disposed of in accordance with local regulations concerning special waste.

● Replace the lithium battery on the system board in accordance with the instructions in the technical manual for the system board D2519).

● All batteries containing pollutants are marked with a symbol (a crossed-out garbage can). In addition, the marking is provided with the chemical symbol of the heavy metal decisive for the classification as a pollutant:

Cd Cadmium Hg Mercury Pb Lead

Notes on handling media and optical disk drives

V CAUTION!

● Use only media in proper condition in the OD drive of your server to prevent data loss, damage to the device and injuries.

● Therefore, check each medium for damage, cracks, breakage etc. before inserting it in the drive.

– Please note that any additional labels applied may change the mechanical properties of a medium and cause imbalance.

– Damaged and imbalanced media can break at high drive speeds (data loss).

– Under certain conditions sharp-edged pieces of a broken medium can penetrate the cover of the drive (damage to the device) and be thrown out of the device (danger of injury, particularly on uncovered body parts such as the face or neck).

Page 19: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 19

Safety notes

I You can protect the OD drive and prevent mechanical damage, as well as premature wearing of the media, by observing the following sugges-tions:

– Only insert the media in the drive when needed and remove them after use.

– Store the media in suitable sleeves.– Protect the media from exposure to heat and direct sunlight.

Note about the laser

The CD-/DVD-ROM drive is classified for laser class 1 according to IEC 60825-1.

V CAUTION!

The OD drive contains a laser diode (LED). Sometimes the LED produces a stronger laser beam than laser class 1. Direct view into this laser beam is dangerous.

Never remove parts of the OD drive assembly!

Page 20: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

20 Options Guide RX300 S4

Safety notes

Modules with electrostatic-sensitive components

Systems and components that might be damaged by electrostatic discharge (ESD) are marked with the following label:

Figure 1: ESD label

When you handle components fitted with ESDs, you must observe the following points under all circumstances:

● Remove the power plug(s) from the power socket(s) before inserting or removing components containing ESDs.

● You must always discharge yourself of static charges (e.g. by touching a grounded object) before working.

● The equipment and tools you use must be free of static charges.

● Only touch the components at the positions highlighted in green (touch points).

● Do not touch any exposed pins or conductors on a component.

● Use a grounding cable designed for this purpose to connect yourself to the system unit as you install components.

● Place all components on a static-safe base.

I You will find a detailed description for handling ESD components in the relevant European or international standards (DIN EN 61340-5-1, ANSI/ESD S20.20).

Page 21: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 21

4 PreparationV CAUTION!

Observe the safety instructions in the chapter “Safety notes” on page 15.

4.1 Removing the server form the rack

Ê Terminate all applications and shut down the server correctly.

Ê If your operating system has not switched off the sever, press the on/off switch.

Ê Pull all power connectors out of the power outlets.

I Depending on the accessibilty it is helpfully to remove the server from the rack. If you don’t want to remove the server from the rack then skip the following section.

Figure 2: Loose the knurled screws and server is pulled out

Ê Loosen the four knurled screws (1) and pull the server as far as possible out of the rack.

Ê Disconnect all cables on the rear of the server.

1

1

2

Page 22: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

22 Options Guide RX300 S4

Opening the server Preparation

I Depending on how accessible the server is in the rack cabinet, it can make sense to remove it from the cabinet. If you do not want to remove the server from the rack cabinet, please skip this page.

Ê Pull the server outward as far as it will go (1), release the hooks (2), then pull out the Server completely.

V CAUTION!

At least two people are needed to lift the server out of the rack cabinet.

4.2 Opening the server

Figure 3: Removing the top cover

Ê Pess the two locking buttons (1) downward.

Ê Slide the cover to the rear side and remove it (2).

4.3 Removing the air duct

I Only if you have to work on the parts of PCI controllers, memory modules or processors do you have to remove the air duct.

2

1

1

Page 23: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 23

Preparation Removing the air duct

Figure 4: Removing the air duct over the main memory and the processors

Ê Lift out the air duct over the main memory.

Page 24: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a
Page 25: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 25

5 Main memoryV CAUTION!

Observe the safety instructions in the chapter “Safety notes” on page 15.

The system board supports up to 48 Gbyte main memory. 4 riser modules with 6 memory banks for main memory are available. Each memory bank can be populated with 512 Mbyte, 1 Gbyte, 2 Gbyte or 4 Gbyte fully buffered DIMM memory modules.

ECC with memory scrubbing and with the Single Device Data Correction (SDDC) function is supported.

5.1 Memory module population

Figure 5: Structure of the main memory in memory banks and memory modules

– The memory banks must be populated continously in pairs with fully buffered DIMM modules (FBD PC2-4200 or FBD PC2-5300).

– One pair of memory modules must consist of identical memory modules.

– The module capacity between pairs can differ: pair 2A/2B can be populated with two 512 Mbyte modules and pair 1A/1B with two 1 Gbyte modules.

I For more information see BIOS-Setup manual and the technical Manual of the system board D2519.

Bild THB 2

DIMM 3C

DIMM 3C

DIMM 2D

DIMM 2C

DIMM 1D

DIMM 1CRis

er

module

2

DIMM 3B

DIMM 3A

DIMM 2B

DIMM 2A

DIMM 1B

DIMM 1A Ris

er

module

1

Page 26: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

26 Options Guide RX300 S4

Upgrading/replacing the main memory Main memory

5.2 Upgrading/replacing the main memory

Ê Open the server as described in the chapter “Safety notes” on page 15.

Ê Remove the air duct see “Removing the air duct” on page 22.

Removing the memory riser module

Figure 6: remove the riser module

Ê Pull out the riser module upward

.

Page 27: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 27

Main memory Upgrading/replacing the main memory

Installing mermory modules

Figure 7: populate memory riser module

Ê Press the holders on either side of the mounting location concerned outward.

Figure 8: populating memory module slots

Page 28: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

28 Options Guide RX300 S4

Upgrading/replacing the main memory Main memory

Ê Insert the memory module in the mounting location and press it down until the holders at the sides engage.

Figure 9: insert riser module

Ê Insert the riser module again.

Ê Push the riser module downward

Ê Insert the air duct, see “Inserting air duct” on page 81.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 81.

Page 29: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 29

6 ProcessorsV CAUTION!

Observe the safety instructions in the chapter “Safety notes” on page 15.

V CAUTION!

Processors are modules which can react extremely sensitively to electro-static discharges and which must therefore always be handled with care. After a processor has been removed from its protective sleeve or from its socket, place it with its smooth side down on a non-conducting, antistatic surface. Never push a processor over a surface.

6.1 Installing a second processor

The system board can be upgraded with a second processor. The upgrade kit consists of a processor, and a heat sink.

V CAUTION!

Only processors of the same type may be used on the system board. The second processor must have the same clock frequency and the same cache as the first processor. For dual operation, use a suitable multipro-cessor operating system.

Ê Open the server as described in the “Removing the air duct” on page 22.

Ê Remove the air duct over the main memory (see chapter “Preparation” on page 22).

Page 30: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

30 Options Guide RX300 S4

Installing a second processor Processors

Figure 10: Removing processor dummy module

Ê Pull the processor dummy out.

V CAUTION!

Keep the dummy cover for future use. If you remove the processor again and do not replace it with a new one, reinstall the dummy cover to ensure that the system is cooled properly.

Page 31: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 31

Processors Installing a second processor

Figure 11: open the pcocessor cover

Ê Release the socket lever and pull it upward as far as it will go.

Page 32: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

32 Options Guide RX300 S4

Installing a second processor Processors

Figure 12: open the processor cover

Ê Open the processor cover.

Page 33: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 33

Processors Installing a second processor

Figure 13: Inserting the processor

Ê Position the new processor over the socket and then carefully press it into the socket.

V CAUTION!

The processor can only be installed in one particular direction. Note the marking on one of the corners. To avoid damaging the pins or the processor, do not force it into the socket.

Ê Lock the processor in the socket by closing the cover and by returning the socket lever to its original position.

Page 34: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

34 Options Guide RX300 S4

Installing a second processor Processors

I When you close the the socket lever, the protective cover will disengage itself.

Figure 14: places of the springs round the heat sink support pins

Ê Check whether the springs round the heat sink support pins are aligned centrally.

Inserting the heat sink

Ê Remove the protective cover on the underside of the heat sink.

Page 35: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 35

Processors Installing a second processor

Figure 15: Installing heat sink

Ê Place the heat sink on the processor.

Ê Fasten the heat sink by tightening the four screws in a crossover pattern.

V CAUTION!

Never install a processor without a heat sink as otherwise the processor may overheat, causing a shut-down of the system.

Ê Reinstall the air duct over the memory and processors see “Inserting air duct” on page 81.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 81.

Page 36: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

36 Options Guide RX300 S4

Replacing the processor Processors

6.2 Replacing the processor

V CAUTION

Only processors of the same type may be used on the system board. The second processor must have the same clock frequency and the same cache as the first processor. For dual operation, use a suitable multipro-cessor operating system.

Ê Open the server as described in the chapter “Preparation” on page 21.

Ê Remove the air duct over the main memory (see “Removing the air duct” on page 22).

Figure 16: Removing the heat sink

Ê Loosen the four screws in a crossover pattern.

Ê Loosen the heat sink by turning it back and forth and then lift it out.

Page 37: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 37

Processors Replacing the processor

Figure 17: Removing the processor

Ê Release the socket lever and pull it upward as far as it will go (1).

Ê Open the socket (2).

Ê Carefully remove the installed processor (3).

2

1

3

Page 38: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

38 Options Guide RX300 S4

Replacing the processor Processors

Figure 18: Inserting a new processor

Ê Position the new processor over the socket and then carefully press it into the socket.

V CAUTION!

The processor can only be installed in one particular direction. Note the marking on one of the corners. To avoid damaging the pins or the processor, do not force it into the socket.

Ê Lock the processor in the socket by closing the cover and by returning the socket lever to its original position.

Page 39: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 39

Processors Replacing the processor heat sink

Ê Remove the protective cover on the underside of the heat sink. Do not touch the pad.

Ê Place the heat sink on the processor socket (see “Inserting the heat sink” on page 34).

Ê Fasten the heat sink by tightening the four screws in a crossover pattern.

Ê Reinstall the air duct over the main memory and the processors (see “Inserting air duct” on page 81).

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 81.

6.3 Replacing the processor heat sink

Ê Open the server as described in section “Opening the server” on page 22.

Ê Remove the air duct over the main memory and the processors (see “Removing the air duct” on page 22).

Ê Loosen the four heat sink screws in a crossover pattern (see section “Replacing the processor” on page 36).

Ê Loosen the heat sink by turning it back and forth and then lift it out.

Ê Clean the upper side of the processor using a lint-free cloth.

Ê Remove the protective cover from the new heat sink.

Ê Place the heat sink on the processor socket (see section “Replacing the processor” on page 36).

Ê Fasten the heat sink by tightening the four screws in a crossover pattern.

Ê Reinstall the air duct over the main memory and the processors (see “Inserting air duct” on page 81).

Page 40: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a
Page 41: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 41

7 Accessible drivesV CAUTION!

Observe the safety instructions in the chapter “Safety notes” on page 15.

I Two free bays are available for accessible drives. One 3,5 Inch x 0,5 Inch is for a FD drive and one 5,25 inch x 0,5 inch is for a ODM drive available. A local view module or a CSS LED module can also be installed Into the upper bay (FD drive).

7.1 Installing a FD drive

Ê Open the server as described in the chapter “Preparation” on page 21.

Removing a FD drive dummy module

Figure 19: Unlocking the FD drive dummy module (for better visibility, the fanbox is removed)

Ê Unlock the FD drive dummy module (1).

Ê Push the FD drive dummy module to the front (2).

1

2

Page 42: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

42 Options Guide RX300 S4

Installing a FD drive Accessible drives

I Carefully pull out the FD drive dummy horizontally, so that the EMV springs will not be damaged.

Figure 20: Removing dummy module

Ê Pull the FD drive dummy module out to the front side.

V CAUTION!

Keep the dummy module for future use. If you remove the FD drive again and do not replace it with a new one, the dummy module must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures.

Page 43: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 43

Accessible drives Installing a FD drive

Installing FD drive

Figure 21: Insert FD drive into the mounting frame.

I The mounting frame and the cable are deliverd with the PRIMERGY RX300 S4.

Ê Insert the FD drive into the mounting frame. Regard the plastic pins. They fix the drive in the frame.

Page 44: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

44 Options Guide RX300 S4

Installing a FD drive Accessible drives

Figure 22: connect the FDD-cable

Ê Connect the cable as shown in the photo.

I Install the cable so, that the blue side shows to the locking mechanism of the connector of the drive.

Ê Thread the cable through the mounting frame.

Page 45: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 45

Accessible drives Installing a FD drive

Figure 23: Inserting FD drive module

Ê Thread the flat cable into the bay.

Ê Push the FD drive module into the bay, until it locks.

I Carefully push in the FD drive dummy horizontally, so that the EMV springs will not be damaged.

Figure 24: Connecting FD drive cable

Ê Connect the FDD cable to the system board.

Page 46: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

46 Options Guide RX300 S4

Installing a LocalView module Accessible drives

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 81.

7.2 Installing a LocalView module

The LocalView module and the CSS module are an optional extra for the servers of the PRIMERGY series. On the display panel of the LocalView module you can read status messages directly from the server. These status messages provide information on the system and notify you of hardware faults (e.g. fan failure, CPU over voltage).

The LocalView module and the CSS module can be pulled out like a sliding drawer. You can also angle the LocalView display panel downward.

Figure 25: LocalView module and CSS module

The LocalView module can be installed in the 3,5/0,5 inch bay of the FD drive.

I In the following section the installation of the LocalView modul is described. The installation of the CSS module is equivalent to this instal-lation

Ê Open the server as described in the chapter “Preparation” on page 21.

Ê If a FDD-dummy module is installed it must be removed (see “Removing a FD drive dummy module” on page 41).

Page 47: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 47

Accessible drives Installing a LocalView module

Removing the FD drive module

Figure 26: Unlocking the FD Drive module (for better visibility, the fanbox is removed)

Ê Unlock (1) the FDD module.

Ê Push the FDD module to the front (2).

I Carefully pull out the FD drive dummy horizontally, so that the EMV springs will not be damaged.

1 2

Page 48: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

48 Options Guide RX300 S4

Installing a LocalView module Accessible drives

Figure 27: unlocking of the FD cable

Ê Remove the FD drive cable from the system board.

Figure 28: Removing FD drive module

Ê Pull the FD drive module out to the front side.

Page 49: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 49

Accessible drives Installing a LocalView module

Figure 29: Thread the cable though to the front.

Ê Thread the cable through the bay to the front side.

Figure 30: Connecting the cable to the LocalView module

Ê Connect the cable to the LocalView module.

Page 50: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

50 Options Guide RX300 S4

Installing a LocalView module Accessible drives

Figure 31: Inserting the LocalView module

I Carefully push in the LocalView module horizontally, so that the EMV springs will not be damaged.

Ê Slide the LocalView module into the mounting location until it latches in place.

I Further information on operation and display modes is provided in the documentation for the LocalView module.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 81.

Page 51: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 51

Accessible drives Installing the optical disk drive

7.3 Installing the optical disk drive

Ê Open the server as described in the chapter “Preparation” on page 21.

Figure 32: Disconnect SATA cable

Ê Remove the SATA cable from the system board.

Page 52: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

52 Options Guide RX300 S4

Installing the optical disk drive Accessible drives

Removing the ODD dummy module

Figure 33: Unlocking the ODD dummy module (for better visibility, the fanbox is removed)

Ê Unlock the ODD dummy module.

Ê Push the ODD dummy module to the front out by the retention mechanism.

I Carefully push out the ODD dummy module horzontally, so that the EMV springs will not be damaged.

1

3

2

Page 53: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 53

Accessible drives Installing the optical disk drive

Figure 34: Removing dummy module

Ê Remove the dummy module from the bay..

V CAUTION!

Keep the dummy module for future use. If you remove the accessible drive again and do not replace it with a new one, the dummy module must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures.

Ê Remove the dummy module from the mounting frame.

Page 54: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

54 Options Guide RX300 S4

Installing the optical disk drive Accessible drives

Figure 35: Installing OD drive in the mounting frame

Ê Install the OD drive in the mounting frame. Regard the plastic pins which fix the drive in the frame.

Figure 36: Connecting the OD drive cables

Ê Thread the power cable (1) through the bay and connect it to the OD Drive (see chapter “Appendix” on page 85).

12

Page 55: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 55

Accessible drives USB tape drive / USB RDX drive

Ê Connect the SATA cable (2) to the drive (see chapter “Appendix” on page 85)

I Carefully push in the ODD module horzontally, so that the EMV springs will not be damaged.

Ê Push the ODD module into the bay completely.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 81.

7.4 USB tape drive / USB RDX drive

I The Installtion of aUSB drive ist only possible for the 6x3,5“ and the 5 x 2,5“ HDD version.

Ê Open the server as described in the chapter “Preparation” on page 21.

Ê Remove the dummys or drives from the two upper bays (see operating manual in the chapter „hot-plug components“.

Figure 37: Push USB drive into the mounting carrier (here you see a tape drive)

Ê Push the tape drive into the mounting carrier.

Ê Insert the 4 screws on the right and left side.

I Use only the delivered M3 x 4,5 screws. Do not use longer screws because you can damage the drive.

Page 56: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

56 Options Guide RX300 S4

USB tape drive / USB RDX drive Accessible drives

Installation of an USB Drive in a 6 x 3,5 Variant

Figure 38: Inserting the power cable

Ê Thread the power cable through the duct to the front.

Page 57: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 57

Accessible drives USB tape drive / USB RDX drive

Figure 39: Inserting the USB cable

Ê Push the USB cable through the duct to the front. The black connector must be routed outside to the front.

Page 58: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

58 Options Guide RX300 S4

USB tape drive / USB RDX drive Accessible drives

Figure 40: Connecting the tape drive

Ê Connect both the cables to the rear side of the tape drive

Page 59: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 59

Accessible drives USB tape drive / USB RDX drive

Figure 41: Installing a USB drive

Ê Push the tape drive in.

Ê When pushing the drive into place pull the cables back so that they do not get pinched.

Figure 42: locking the drive

Page 60: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

60 Options Guide RX300 S4

USB tape drive / USB RDX drive Accessible drives

Ê Lock the drive.

Figure 43: Connecting USB cable to the system board

Ê Connect the USB Cable to the USB1 (1) connector on the system board.

Ê Connect the power cable to the SAS backplane(2).

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 81.

2

1

Page 61: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 61

Accessible drives USB tape drive / USB RDX drive

Installation of an USB drive in 6 x 2,5“ Variante

Figure 44: Inserting the power cable

Ê Thread the power cable through the duct to the front

Figure 45: Connecting the cables

Page 62: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

62 Options Guide RX300 S4

USB tape drive / USB RDX drive Accessible drives

Ê Connect the power cable to the USB drive.

Ê Connect the USB cable to the USB drive.

Figure 46: Installing a USB drive

Ê Push the tape drive in.

Ê When pushing the drive into place pull the cables back so that they do not get pinched.

Page 63: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 63

Accessible drives USB tape drive / USB RDX drive

Figure 47: Locking the drive

Ê Lock the drive.

Figure 48: Connecting the USB cable to the system board

Ê Connect the USB-Kabel to the system board on USB 1.

Page 64: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a
Page 65: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 65

8 PCI slotsV CAUTION!

Observe the safety instructions in the chapter “Safety notes” on page 15.

I The system board offers seven low-profile PCI slots.

There are no hot-plug PCI slots.

As a standard slot 1 is occupied with a SAS controller.

You will find an overview of the slots in the techical manual of the system board D2519.

8.1 Installing a PCI controller

Ê Open the server as described in the chapter “Preparation” on page 21.

Figure 49: Remove the slot cover

Ê Removing the screw of the slot cover of the slot you will populate.

Ê Remove the slot cover.

Page 66: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

66 Options Guide RX300 S4

Installing a PCI controller PCI slots

V CAUTION!

Keep the rear cover of the PCI slot for future use. If you remove the controller again and do not replace it with a new one, the rear cover must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures.

Figure 50: Inserting controller

Ê Install the controller in the PCI slot and press it carefully into the associated plug-in location on the system board.

Ê Fasten the slot cover with the screw.

Ê If required, connect the cables to the controller and other components.

Ê Insert the air duct, see “Inserting air duct” on page 81.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 81.

Page 67: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 67

9 SAS controllerV CAUTION!

Observe the safety instructions in the chapter “Safety notes” on page 15.

I In the chapter you will find the description of the upgrade from SAS IME controller to SAS RAID controller. The conversion from SAS RAID to SAS IME is correspondingly.

9.1 Upgrading a SAS controller

I A SAS controller is required for operating internal hard disk drives. For this purpose a SAS IME or a SAS RAID controller is available.

Ê Open the server as described in the chapter “Preparation” on page 21.

Ê Remove the air duct, see “Removing the air duct” on page 22.

Figure 51: SAS RAID controller with low-profile

Ê Fasten the slot cover (low-profile) with the two screws in the square holes.

Ê Insert the RAID key.

Page 68: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

68 Options Guide RX300 S4

Upgrading a SAS controller SAS controller

Figure 52: Remove the controller

Ê Remove the screw.

Ê Remove both SAS-cables.

Ê Lift the contoller upward.

Page 69: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 69

SAS controller Upgrading a SAS controller

Figure 53: Inserting controller

Ê Install the controller in the PCI slot 1 and press it carefully down.

Ê Fasten the slot cover with a screw.

Ê Connect plug X1 up and plug X2 down on the controller.

Ê Insert the air duct, see “Inserting air duct” on page 81.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 81.

X1X2

Page 70: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a
Page 71: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 71

Battery for PCI boards Installing the battery module for PCI boards

10 Battery for PCI boardsV CAUTION!

Observe the safety instructions in the chapter “Safety notes” on page 15.

10.1 Installing the battery module for PCI boards

Ê Open the server as described in the chapter “Preparation” on page 21.

Figure 54: Removing the battery holder

Ê Unlock the battery holder.

Ê Remove the battery holder.

Page 72: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

72 Options Guide RX300 S4

Installing the battery module for PCI boards Battery for PCI boards

Figure 55: Removing the battery holder

Ê Insert the battery module between the guidings (1) of the battery holder.

Ê Press the battery module into the upper holders until it will engage under the noses (2).

Figure 56: Connecting cable

Ê Connect the cable from the battery to the connector of the card if necessary.

1

2

Page 73: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 73

Battery for PCI boards Installing the battery module for PCI boards

Figure 57: Battery holder with battery module

Figure 58: Battery basic holder

Ê Insert the populated battery holder into the recesses of the battery basic holder.

Page 74: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

74 Options Guide RX300 S4

Installing the battery module for PCI boards Battery for PCI boards

Figure 59: Inserting battery holder into the battery basis holder

Ê Turn the battery holder upward.

Figure 60: Inserted battery module

Page 75: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 75

Battery for PCI boards Installing the battery module for PCI boards

Figure 61: Inserting cable

Ê Insert the connection cable beween the battery and the controller.

I Regard the coding of the connectors. The white bar must show to the board.

Ê Push the cable behind the boards.

– Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 81.

Page 76: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a
Page 77: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 77

11 External serial interfaceV CAUTION!

Observe the safety instructions in the chapter “Safety notes” on page 15.

11.1 Installing the external serial interface

Ê Open the server as described in the chapter “Preparation” on page 21.

External serial interface

Figure 62: External serial cable with low-profile slot cover

Ê Remove slot cover of Slot 7 ( see “Remove the slot cover” on page 65).

Page 78: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

78 Options Guide RX300 S4

Installing the external serial interface External serial interface

V CAUTION!

Keep the rear cover of the PCI slot for future use. If you remove the controller again and do not replace it with a new one, the rear cover must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures.

Figure 63: Installing external serial cable

Ê Insert the slot cover with the serial interface.

Ê Fasten the slot cover with a screw.

Ê Route the serial cable, as shown in the picture.

Ê Insert the air duct, see “Inserting air duct” on page 81.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 81.

Page 79: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 79

12 External parallel interfaceV CAUTION!

Observe the safety instructions in the chapter “Safety notes” on page 15.

12.1 Installing an external parallel interface

Ê Open the server as described in the chapter “Preparation” on page 21.

I If you install the parallel interface additional to an external serial interface, the parallel interface is to install in slot 6.

Parallel interface in standard configuration

Figure 64: external parallel interface with low-profile slot cover

Ê Remove slot cover of slot 7 (see “Remove the slot cover” on page 65).

Page 80: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

80 Options Guide RX300 S4

Installing an external parallel interface External parallel interface

V CAUTION!

Keep the rear cover of the PCI slot for future use. If you remove the controller again and do not replace it with a new one, the rear cover must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures.

Figure 65: Routing the cable

Ê Insert the slot cover with the parallel interface into slot 7.

Ê Fasten the slot cover with a screw.

Ê Connect the cable to the system board (see arrow).

Ê Route the cable as shown in the picture directly upon the system board.

Ê Insert the air duct, see “Inserting air duct” on page 81.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 81.

Page 81: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 81

13 Completion

13.1 Inserting air duct

Figure 66: Installing the air duct over the memory and processors

Ê Reinstall the air duct over the memory and the processors.

Page 82: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

82 Options Guide RX300 S4

Closing the server Completion

13.2 Closing the server

Figure 67: Closing the cover

Ê Apply the cover.

Ê Push the cover to the front (1).

Ê Make sure that the locks engage.

13.3 Installing the server into the rack

I If you have not removed the server from the rack cabinet, please skip this page.

1

Page 83: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 83

Completion Installing the server into the rack

Figure 68: Installing the server in a rack cabinet

V CAUTION!

At least two people are required to install the server in the rack cabinet.

Ê Lower the server from above onto the extended telescopic rails.

Ê Push the server in the direction of the arrow (1) until the hooks of the telescopic rails engage.

Ê Release the telescopic rails’ locking mechanism (2) on both sides and push the server as far as it will go into the rack.

Ê Reconnect all the cables you disconnected beforehand on the rear of the server. Also connect also the new cables.

Ê Fasten the server in the rack using the two knurled screws (3).

Ê Connect all power plugs to the power outlets.

Ê Press the on/off key to start up the server.

1

2

3

3

Page 84: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a
Page 85: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 85

14 Appendix

14.1 Cabling

6 x 3,5“ HDD Variante

The following table gives you an overview of the cables:

*refers to the drawings of the cabling

Cable # *

Part number Item number Designation

1 T26139-Y3910-V2 A3C40058008 Parallel Port (optional)

2 T26139-Y3694-V103 A3C40071653 SV 20 pol

3 T26139-Y3758-V7 A3C40057188 SV 24 pol

4 T26139-Y3986-V1 A3C40089215 PS 16P 3,5"

5 T26139-Y3925-V302 A3C40089216 Front Panel

6 T26139-Y3958-V202 A3C40075504 SATA

7 T26139-Y3696-V12 A3C40057186 FDD

8 T26139-Y3589-V651 A3C40071502 Seriell Port (optional)

9 T26139-Y3807-V101 A3C40089220 USB

10 T26139-Y3959-V201 A3C40074671 PSTape Drive (optional)

11 T26139-Y3973-V92 A3C40083897 USB Tape Drive (optional)

12 T26139-Y3963-V51 A3C40089467 SAS left

13 T26139-Y3963-V52 A3C40089469 SAS right

14 T26139-Y3987-V3 A3C40092034 BBU

Page 86: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

86 Options Guide RX300 S4

Cabling Appendix

Figure 69: Cabling PRIMERGY RX300 S4 with 3,5“ HDDs

Systemboard

D2519

PCIe card

SAS/RAID

D2507/D2516

Chassis ID

CSS /

Local view

I2C

Frontpanel

FDD Panel

USB

SAS backplane

Serial2

Tape Drive

(Option)

ODD

(Option)

FDD

(Option)

Power

backplane

Parallel port

(Option)

Serial 2 port

(Option)

1

8

2

6

5 5

3

4

7

9

13

11

10

12

14

Page 87: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 87

Appendix Cabling

6x 2,5 HDD Variante

The following table gives you an overview of the cables:

*refers to the drawings of the cabling

Cable # *

Part number Item number Designation

1 T26139-Y3910-V2 A3C40058008 Parallel Port (optional)

2 T26139-Y3694-V103 A3C40071653 SV 20 pol

3 T26139-Y3758-V7 A3C40057188 SV 24 pol

4 T26139-Y3986-V201 A3C40089339 16P 2,5" TD

5 T26139-Y3925-V302 A3C40089216 Front Panel

6 T26139-Y3958-V202 A3C40075504 SATA

7 T26139-Y3696-V12 A3C40057186 FDD

8 T26139-Y3589-V651 A3C40071502 Serieller Port (optional)

9 T26139-Y3807-V101 A3C40089220 USB

11 T26139-Y3973-V92 A3C40083897 USB Tape Drive (optional)

12 T26139-Y3963-V104 A3C40089471 2x SAS 6x2,5" Kabel (bundle)

14 T26139-Y3987-V3 A3C40092034 BBU

Page 88: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

88 Options Guide RX300 S4

Cabling Appendix

Figure 70: Cabling PRIMERGY RX300 S4 mit 6 x 2,5“ HDDs

Systemboard

D2519

Chassis IDCSS /

Local view

I2C

Frontpanel

FDDpanel

USB

SAS backplane

Serial2

Tape drive

(Option)

ODD

(Option)

FDD

(Option)

Power

backplane

Parallel port

(Option )

Serial 2 port

(Option )

PCIe card

SAS/RAID

D2507/D2516

8

1

2

3 4

5 5

6

7

11

9

1212

14

Page 89: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 89

Appendix Cabling

12 x 2,5“ HDD Variante

The following table gives you an overview of the cables:

*refers to the drawings of the cabling

Cable # *

Part number Item number Designation

1 T26139-Y3910-V2 A3C40058008 Parallel Port (optional)

2 T26139-Y3694-V103 A3C40071653 SV 20 pol

3 T26139-Y3758-V7 A3C40057188 SV 24 pol

4 T26139-Y3986-V101 A3C40089229 PS 16P 2,5"

5 T26139-Y3925-V302 A3C40089216 Front Panel

6 T26139-Y3958-V202 A3C40075504 SATA

7 T26139-Y3696-V12 A3C40057186 FDD

8 T26139-Y3589-V651 A3C40071502 Seriell Port (optional)

9 T26139-Y3807-V101 A3C40089220 USB

12 T26139-Y3963-V251 A3C40092085 SAS 12x2,5 left

13 T26139-Y3963-V252 A3C40092087 SAS 12x2,5 right

14 T26139-Y3987-V3 A3C40092034 BBU

Page 90: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

90 Options Guide RX300 S4

Cabling Appendix

Figure 71: Cabling PRIMERGY RX300 S4 mit 12 x 2,5“HDDs

Chassis ID CSS

Local view

I2C

Frontpanel

Expander board

ODD

(Option)

FDD

(Option)

Serial 2port

(Option)

55

6

912 13

14

Page 91: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 91

Appendix Configuration diagram

14.2 Configuration diagram

Figure 72: Part of the system configurator 3.5“ HDD

PS 1 Drive Area based on

3 different SAS-BP

SB D2519

T4 (ambient sensor, located

at ID-Temp board)

Drive Area based on

3 different SAS-BP

CPU 1

CPU 2

Memory

on Riser

Power

Backplane

PS 2

redundant

FAN1

CPU

FAN1

SYS

Slots 2-7

FAN2

CPU

FAN3

CPU

FAN6

CPU

red

FAN5

CPU

red

FAN4

CPU

red

FAN2

SYS

red

FAN PS 2

FAN PS 1

Slot 1 D2507/D2516

HDD 3x3,5“

HDD 6x2,5“

HDD 3x3,5“

HDD 6x2,5“

HDD 1x3,5“+

TD / RDX

HDD 6x2,5“

Area for

FDD or Local View / CSS

on top and

ODD

at the bottom

T5 …T16

T1

T3

T2

T1 = Temp.sens. CPU 1

T2 = Temp.sens. CPU 2

T3 = Temp.sens. Board (not used for fan control)

T4 = Temp.sens. Ambient

T5 …T16 = Temp.sens. AMB

TD/

RDX

Page 92: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a
Page 93: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 93

AbbreviationsAC

Alternating Current

ANSIAmerican National Standard Institut

ASR&RAutomatic Server Reconfiguration and Restart

BIOSBasic Input-Output System

BMCBaseboard Management Controller

CCCache Coherency

CDCompact Disk

CD-ROMCompact Disk-Read Only Memory

CHSCylinder Head Sector

CMOSComplementary Metal Oxide Semiconductor

COMCommunication

CPUCentral Processing Unit

DCDirect Current

Page 94: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

94 Options Guide RX300 S4

Abbreviations

DIMMDual Inline Memory Module

DIPDual Inline Package

DMADirect Memory Access

DMIDesktop Management Interface

ECCErrror Checking and Correcting

ECPExtended Capabilities Port

EEPROMElectrically Erasable Programmable Read-Only Memory

EMCElectroMagnetic Compatibility)

EMPEmergency Management Port

EPPEnhanced Parallel Port

ESDElectroStatic Discharge

FPCFront Panel Controller

FRUField Replaceable Unit

Page 95: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 95

Abbreviations

FSBFront Side Bus

GAMGlobal Array Manager

GUIGraphical User Interface

HDDHard Disk Drive

HSCHot-Swap Controller

I²CInter-Integrated Circuit

I/OInput/Output

ICMIntelligent Chassis Management

IDIdentification

IDEIntergrated Drive Electronics

IOOPIntetelligent Organization of PCI

IRQInterrupt Request Line

LANLocal Area Network

LBALogical Block Address

Page 96: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

96 Options Guide RX300 S4

Abbreviations

LCDLiquid Crystal Display

LUNLogical Unit Number

LVDLow-Voltage Differential SCSI

MMFMulti Mode Faser

MRLManually Retention Latch

NMINon Maskable Interrupt

NVRAMNon Volatile Random Access Memory

OSOperating System

PCIPeripheral Component Interconnect

PDAPrefailure Detection and Analysing

POSTPower ON Self Test

RAIDRedundant Arrays of Independent Disks

RAMRandom Access Memory

ROMRead-Only Memory

Page 97: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 97

Abbreviations

RSBRemote Service Board

RTCReal Time Clock

RTDSRemote Test- und Diagnose-System

SAF-TESCSI Accessed Fault-Tolerance Enclosures

SBESingle Bit Error

SCASingle Connector Attachment

SCSISmall Computer System Interface

SDDCSingle Device Data Correction

SDRSensor Data Record

SDRAMSynchronous Dynamic Random Access Memory

SELSystem Event Log

SMISystem Management Interrupt

SSUSystem Setup Utility

SVGASuper Video Graphics Adapter

Page 98: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

98 Options Guide RX300 S4

Abbreviations

USBUniversal Serial Bus

VGAVideo Graphics Adapter

Page 99: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

RX300 S4 Options Guide 99

IndexAaccessible drives 9, 41air duct 23

Ccomponents

hardware/software 7Controller 11, 65CSS 10CSS failures 13Customer Self Service (CSS) 10

DDamaged and imbalanced media 18data manipulation 7dual operation 29, 36

EESD (electrostatic sensitive

device) 20external parallel interface 12external serial interface 12, 77

FFurther sources of information 8

Hhard disk drive 11hard disk drive configurations 11heat sink 39

Iinformation material, additional 8

Llight-emitting diode (LED) 19Lithium battery 18LocalView module 10, 46

Mmain memory 9manipulation of data 7

meaning of the symbols 12medium 18multiprocessor operating system 29,

36

Nnotational conventions 12note about the laser 19

Pparallel interface 79processor 9, 29processor heat sink 39

RRDX-drive 9

SSAS IME 9SAS RAID 9security functions 7slot cover 77

TTape drive 9target group 7

Page 100: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a
Page 101: PRIMERGY RX300 S4 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/RX300_S4/pdf/og.pdfRX300 S4 Options Guide ... You can also fit your server with a

Information on this document On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Compu-ters. This new subsidiary of Fujitsu has been renamed Fujitsu Technology So-lutions.

This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed.

Please note that all company references and copyrights in this document have been legally transferred to Fujitsu Technology Solutions.

Contact and support addresses will now be offered by Fujitsu Technology So-lutions and have the format …@ts.fujitsu.com.

The Internet pages of Fujitsu Technology Solutions are available at http://ts.fujitsu.com/... and the user documentation at http://manuals.ts.fujitsu.com.

Copyright Fujitsu Technology Solutions, 2009

Hinweise zum vorliegenden Dokument Zum 1. April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu übergegangen. Diese neue Tochtergesellschaft von Fujitsu trägt seit-dem den Namen Fujitsu Technology Solutions.

Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor längerer Zeit freigegebene oder nicht mehr im Vertrieb befindliche Produktversion.

Bitte beachten Sie, dass alle Firmenbezüge und Copyrights im vorliegenden Dokument rechtlich auf Fujitsu Technology Solutions übergegangen sind.

Kontakt- und Supportadressen werden nun von Fujitsu Technology Solutions angeboten und haben die Form …@ts.fujitsu.com.

Die Internetseiten von Fujitsu Technology Solutions finden Sie unter http://de.ts.fujitsu.com/..., und unter http://manuals.ts.fujitsu.com finden Sie die Benutzerdokumentation.

Copyright Fujitsu Technology Solutions, 2009