bx620 s4 2 - fujitsu global · bx620 s4 with 1gbit/s ethernet i/o module and bx620 s4 with 4gbit/s...

2
2GB (MAX. 32GB) ECC DDR2 SDRAM FB DIMM Onboard SAS x2 (RAID1) HDD 2 Bays (MAX. 293.6GB) PRIMERGY BX620 S4 provides a range of future orien- ted technologies; with processors (Dual- or Quad-Core), memory (FBD, extended mirroring), and 2.5 inch SAS hard disk drives. Innovative use of such capabilities enables PRIMERGY BX620 S4 customers to run much larger applications than on previous Dual- or Quad-Core Server Blades. The SAS hard disk drives with RAID1 better meet your growing de- mands for higher levels of data security. While your specif- ic configurations can be very easily established, either built to order in the factory or on your site. This is because the different storage modules come with an intelligent mounting cage for efficient blade and storage deployment. Up to ten blade servers can be mounted in a single chassis unit. The latest Intel ® Xeon ® Processor technology and up to 8 x LAN interfaces – guarantees high performance and reli- ability. Up to two supporting CPUs can be mounted on a single server blade. ECC memory (standard) prevents the blade server from system interruptions due to memory errors. Hard disks on the server blade can also be configured into arrays. All modules including server blades, management blades and switch blades support redundancy and hot plug- ging, ensuring high availability. Both external and internal LAN are supported as high- speed LAN (Gigabit-LAN) and redundant LAN, for high performance and availability. Server management, remote control and other server supervision functions are provided by the Server management blade and LAN ports. Since connection of multiple servers is enabled, PRI- MERGY BX620 S4 supports a wide range of server func- tions from front-end servers to application servers. Enhanced Support for More Efficient Server Consolidation 2 BX620 S4 Intel ® Xeon ® X5470 (3.33GHz)/X5460 (3.16GHz)/E5420 (2.50GHz)/L5410 (2.33GHz)/E5405 (2GHz) Intel ® Xeon ® X5270 (3.50GHz)/X5260 (3.33GHz)/E5205 (1.86GHz) PCI Express (x4) [x8] PCI-X (64bit/133MHz)[3.3V]

Upload: nguyenduong

Post on 04-Dec-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

2GB (MAX. 32GB) ECC DDR2 SDRAM FB DIMM

Onboard SAS x2 (RAID1)

HDD 2 Bays (MAX. 293.6GB)

PRIMERGY BX620 S4 provides a range of future orien-ted technologies; with processors (Dual- or Quad-Core), memory (FBD, extended mirroring), and 2.5 inch SAS hard disk drives.

Innovative use of such capabilities enables PRIMERGY BX620 S4 customers to run much larger applications than on previous Dual- or Quad-Core Server Blades. The SAS hard disk drives with RAID1 better meet your growing de-mands for higher levels of data security. While your specif-ic configurations can be very easily established, either built to order in the factory or on your site.

This is because the different storage modules come with an intelligent mounting cage for efficient blade and storage deployment.Up to ten blade servers can be mounted in a single chassis unit. The latest Intel® Xeon® Processor technology and up

to 8 x LAN interfaces – guarantees high performance and reli-ability. Up to two supporting CPUs can be mounted on a single server blade. ECC memory (standard) prevents the blade server from system interruptions due to memory errors. Hard disks on the server blade can also be configured into arrays. All modules including server blades, management blades and switch blades support redundancy and hot plug-ging, ensuring high availability.

Both external and internal LAN are supported as high-speed LAN (Gigabit-LAN) and redundant LAN, for high performance and availability. Server management, remote control and other server supervision functions are provided by the Server management blade and LAN ports.

Since connection of multiple servers is enabled, PRI-MERGY BX620 S4 supports a wide range of server func-tions from front-end servers to application servers.

Enhanced Support for More Efficient Server Consolidation

2

*When option applied

BX620 S4Intel® Xeon® X5470 (3.33GHz)/X5460 (3.16GHz)/E5420 (2.50GHz)/L5410 (2.33GHz)/E5405 (2GHz) Intel® Xeon® X5270 (3.50GHz)/X5260 (3.33GHz)/E5205 (1.86GHz)

Dual Core Intel¨ Xeon¨ Processor

5160 3GHz /5130 2GHz

5080 3.73GHz/5060 3.20GHz/5050 3GHz

PCI Express (x4) [x8]PCI-X (64bit/133MHz)[3.3V]

FUJITSU LIMITEDhttp://primergy.fujitsu.com

Specifications are subject to change without notice. Other brand names and product names are trademarks and registered trademarks of their respective holders.

©2008 Fujitsu Limited. All rights reserved.

Eighth edition, December 2008

Environmental LabelThe FUJITSU Group environmental logo was designed to be used by all Group companies in November, 1994. Categorized in the ISO14020 international standard, it indicates Green or Super Green products where special considerations have been given to environmental protection.

http://www.fujitsu.com/global/about/environment/

* 1 :

Available memory capacity will be changed by the type of OS. Please find more details in Notes[Memory OS Compatibility List].* 2: Resolution is determined by functions of the display monitor and OS.* 3 : HDD capacity is calculated according to the formula 1GB=10003 byte* 4

: CPU Conversion kit: Xeon E5205 (1.86GHz) -> Xeon X5470 (3.33GHz) is available for upgrading to Intel® Xeon® X5470 (3.33GHz).* 5

: CPU Conversion kit: Xeon E5205 (1.86GHz) -> Xeon E5460 (3.16GHz) is available for upgrading to Intel® Xeon® E5460 (3.16GHz). * 6 : CPU Conversion kit: Xeon E5205 (1.86GHz) -> Xeon E5420 (2.50GHz) is available for upgrading to Intel® Xeon® E5420 (2.50GHz). * 7 : CPU Conversion kit: Xeon E5205 (1.86GHz) -> Xeon X5405 (2GHz) is available for upgrading to Intel® Xeon® X5405 (2GHz). * 8 : CPU Conversion kit: Xeon E5205 (1.86GHz) -> Xeon X5270 (3.50GHz) is available for upgrading to Intel® Xeon® X5270 (3.50GHz).* 9 : CPU Conversion kit: Xeon E5205 (1.86GHz) -> Xeon X5260 (3.33GHz) is available for upgrading to Intel® Xeon® X5260 (3.33GHz).*10 : 1Gbit/s Ethernet I/O Module is available when Switch Blade or GbE Pass-Thru Blade or Cisco Catalyst Blade Switch 3040 are mounted on Network Blade Slot 3,4 of BX600 S3 Blade Server System Unit. BX620 S4 with 1Gbit/s Ethernet I/O Module and BX620 S4 with 4Gbit/s FC I/O Module are not allowed to be mounted together on same BX600 S3 Blade Server System Unit.*11: 4Gbit/s FC I/O Module is available when FC Switch Blade or FC Pass-Thru Blade are mounted on Network Blade Slot 3,4 of BX600 S3 Blade Server System Unit. BX620 S4 with 1Gbit/s Ethernet I/O Module and BX620 S4 with 4Gbit/s FC I/O Module are not allowed to be mounted together on same BX600 S3 Blade Server System Unit.*12: Display, DVD-ROM and FDD can be connected to the Display/USB Extension connector of base unit with Display/USB Extension Cable. One Display/USB Extension Cable is attached as standard with one BX600 S3 Blade Server System Unit.*13: These are connected to KVM Module (standard) or Advanced KVM Module (optional) in BX600 S3 Blade Server System Unit.*14: Total number of cores of CPU(s) should be four or more for using VM (Virtual Machine) function.

*1

: One BX620 S4 occupies One Server Blade Slot.*2

:

Display, Keyboard and Mouse can be connected by using Display/PS/2 Extension Cable attached as standard with BX600 S3 Blade Server System Unit.* When BX600 S3 Blade Server System Unit is ordered, Switch Blade or GbE Pass-Thru Blade or Cisco Catalyst Blade Switch 3040 should be ordered at a time.

* Noise level is 65dB.

SpecificationsType

Model

Frequencies

Second-Level-Cache

Number of Processors

Number of cores

Standard

Maximum*1

Number of Bays

Available HDD*3

Maximum*3

PCI Express (x4) [x8]

PCI-X (64bit/133MHz) [3.3V]

Voltage

Power Consumption

BX620 S4

CPU

Front-Side-Bus

Chipset

Memory

Graphics Controller

Resolution*2

Internal Bays2.5 inchHDD(SAS)

PCI Slots RAID

SAS Interface (Onboard)

LAN Interfaces

Fibre channel Interfaces

Interfaces

Server Management Software

Power Supply

Dimensions (W x D x H (mm))

Weight

Environmental Conditions

OS Support

10 (hot plug)*1

4 (hot plug)

2 (Management Blade x 2 installed as standard) (hot plug) Display(Analog RGB)*2,

Keyboard (PS/2type Mini DIN 6pins)*2,Mouse (PS/2type Mini DIN 6pins)*2

(KVM Module x 1 installed as standard)

AC200-240V (50/60Hz) (NEMA L6-30)x2 (Max. 4)

5250W/18900kJ/h (max.)optional (hot plug)

standard (hot plug)

446 (483 incl. protruding parts)x735 (800 incl. protruding parts)x308 (7U)

130kg (138kg incl. rack rails)(max.)

Server Blade Network Blade (LAN/Fibre Channel)

Management Blade (standard)

VoltagePower consumption Redundant power supply

Slots

KVM Module

Power supply

Redundant Fan

Dimensions ( WxDxH (mm) )

Weight (kg)

Type BX600 S3 Blade Server System Unit

Dual-Processor Blade Server2.5inch SAS model

Intel¨ Xeon¨ X5470 (3.33GHz)*4/X5460 (3.16GHz)*5/E5420 (2.50GHz)*6/L5410 (2.33GHz)/E5405 (2GHz)*7/X5270 (3.50GHz)*8/X5260 (3.33GHz)*9/E5205 (1.86GHz)

12MB(Intel¨ Xeon¨ X5470 (3.33GHz)/X5460 (3.16GHz)/E5420 (2.50GHz)/L5410 (2.33GHz)/E5405 (2GHz))/6MB(Intel¨ Xeon¨ X5270 (3.50GHz)/X5260 (3.33GHz)/E5205 (1.86GHz))

1(max. 2)

4 per processor (Intel¨ Xeon¨ X5470 (3.33GHz)/X5460 (3.16GHz)/E5420 (2.50GHz)/L5410 (2.33GHz)/E5405 (2GHz))/2 per processor (Intel¨ Xeon¨ X5270 (3.50GHz)/X5260 (3.33GHz)/E5205 (1.86GHz))

1333MHz (Intel¨ Xeon¨ X5470 (3.33GHz)/X5460 (3.16GHz)/E5420 (2.50GHz)/L5410 (2.33GHz)/E5405 (2GHz)/Intel¨ Xeon¨ X5270 (3.50GHz)/X5260 (3.33GHz))/1066MHz (Intel¨ Xeon¨ E5205 (1.86GHz))

Intel®5000P

2GB (1GB ECC DDR2 SDRAM Fully Buffered DIMM x 2, PC2 5300F)(SDDC (Single Device Data Correction) supported)

32GB (4GB ECC DDR2 SDRAM Fully Buffered DIMMx8, PC2 5300F)

ATI ES 1000, VRAM : 16MB (PCI)

640x480/800x600/1024x768/1280x1024 dot

2

2.5inch, SAS, 10krpm, 73.4GB2.5inch, SAS, 10krpm, 146.8GB2.5inch, SAS, 15krpm, 73.4GB

293.6GB

optional (1 : LowProfile PCI Express Card only when Expansion Card Slot Module is applied.)

optional (1 : LowProfile PCI Card only when Expansion Card Slot Module is applied.)

standard (Onboard, with RAID1 function)

SAS x 2ports

6ports (1Gbps)(8ports (1Gbps) when 1Gbit/s Ethernet I/O Module (2ports(1Gbps)) is applied.)*10

Optional (2ports(4Gbps) when 4Gbit/s FC I/O Module (2ports(4Gbps)) is applied.)*11

Display (Analog RGB)*12, USB x2 (ver. 2.0)*12, Display*13, Keyboard*13, Mouse*13

ServerView (optional)

DC12V/DC5V-Standby (provided by BX600 S3 Blade Server System Unit)

347W/1250kJ/h (max.) (Intel¨ Xeon¨ X5470 (3.33GHz)/X5460 (3.16GHz)/E5420 (2.50GHz)/E5405 (2GHz)/X5270 (3.50GHz)/X5260 (3.33GHz)/E5205 (1.86GHz)/240W/864kj/h (max.) (Intel¨ Xeon¨ L5410 (2.33GHz))

42x476x286 (Server blade slot of BX600 S3 Blade Server System Unit x1)

7.0kg (max.)

Temperature10-35°C/Humidity 20-80% (non condensing)

Windows Server® 2008 Standard (32-bit)/Windows Server® 2008 Enterprise (32-bit) Windows Server® 2008 Standard (64-bit)/Windows Server® 2008 Enterprise (64-bit)

Windows Server® 2003 R2, Standard Edition/Windows Server® 2003 R2, Standard Edition (SP2) Windows Server® 2003 R2, Enterprise Edition/Windows Server® 2003 R2, Enterprise Edition (SP2)

Windows Server® 2003, Standard Edition (SP1/SP2)/Windows Server® 2003, Enterprise Edition (SP1/SP2) Windows Server® 2003 R2, Standard x64 Edition/Windows Server® 2003 R2, Standard x64 Edition (SP2)

Windows Server® 2003 R2, Enterprise x64 Edition/Windows Server® 2003 R2, Enterprise x64 Edition (SP2) Windows Server® 2003, Standard x64 Edition/Windows Server® 2003, Standard x64 Edition (SP2)

Windows Server® 2003, Enterprise x64 Edition/Windows Server® 2003, Enterprise x64 Edition (SP2) Red Hat Enterprise Linux ES (v.4 for x86)/Red Hat Enterprise Linux AS (v.4 for x86)

Red Hat Enterprise Linux 5 (for x86)*14 Red Hat Enterprise Linux ES (v.4 for EM64T)/Red Hat Enterprise Linux AS (v.4 for EM64T)

Red Hat Enterprise Linux 5 (for Intel64)*14

©2008 Fujitsu Limited.All rights reserved.

BK0131-53

BK00271141