polarimeter - icientifica.com · polarimeter polartronic n & m touch laboratory polarimeter...

2
Polarimeter Polartronic N & M TOUCH Laboratory Polarimeter Polartronic N & M TOUCH-series • High-performance Circle Polarimeter for common applications • Robust metal housing Highly accurate and reproducible measuring results of the whole measuring range in no time at all Continuous measurements for control of changes in concentration, depending on time or reaction • Adopted user friendly Operation System displayed by a high resolution 7“ TFT Touchscreen • Easy to calibrate by certified Quartz Control Plates (SQCP, TQCP) • Modern and robust design for rough environments • Internal measuring data storage • Documentation according to GLP/GMP, 21 CFR part 11 ready, software optionally available • Energy saving LED light source • Extremely low noise • Minimal maintenance effort • Remote diagnostics and servicing Lab

Upload: others

Post on 06-Jan-2020

32 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Polarimeter - icientifica.com · Polarimeter Polartronic N & M TOUCH Laboratory Polarimeter Polartronic N & M TOUCH-series • High-performance Circle Polarimeter for common applications

Polarimeter Polartronic N & M TOUCH

Laboratory Polarimeter Polartronic N & M TOUCH-series

• High-performance Circle Polarimeter for common applications• Robust metal housing• Highly accurate and reproducible measuring results of the whole measuring range in no time at all • Continuous measurements for control of changes in concentration, depending on time or reaction • Adopted user friendly Operation System displayed by a high resolution 7“ TFT Touchscreen• Easy to calibrate by certified Quartz Control Plates (SQCP, TQCP)• Modern and robust design for rough environments• Internal measuring data storage • Documentation according to GLP/GMP, 21 CFR part 11 ready, software optionally available • Energy saving LED light source • Extremely low noise• Minimal maintenance effort• Remote diagnostics and servicing

Lab

Page 2: Polarimeter - icientifica.com · Polarimeter Polartronic N & M TOUCH Laboratory Polarimeter Polartronic N & M TOUCH-series • High-performance Circle Polarimeter for common applications

SCHMIDT+HAENSCH GmbH & Co. Waldstraße 80/81 | D-13403 Berlin | Germany Phone: +49 30 / 41 70 72-0 | Fax: +49 30 / 41 70 72-99 www.schmidt-haensch.com | [email protected]

ISO 9001:2008

SCH

MID

T+H

AEN

SCH

rese

rved

all

right

s ov

er te

xts

and

imag

es

Software features at a glance

• Menu guided operation system• Personalizing of the display and data output

• Context interactive help function (Help button)

• User editable and programmable formulas

quartz control plates • Traceability of all calibration procedures

• Easy integration into other external LIMS systems• Quick reset to factory defaults

• User friendly self-diagnostics options and easy service and support references• Remote diagnostics and servicing capabilities

Quartz control plates

For laboratories working according to Good Laboratory Practice (GLP) or Good Manufacturing Practice (GMP) guidelines or international regulations it’s mandatory to regularly verify instrument performance. Quartz control plates are long time stable laboratory standards recommen -ded by national pharmacopeia‘s and standards like ICUMSA (International Commission for Uniform Methods of Sugar Analysis) for this purpose.Apart from the well-known single quartz control plates (SQCP), there are now also triple quartz control plates

di�erent rotation values at each 7 wavelengths.

Specifications Polartronic N TOUCH Polartronic M TOUCHMeasurement scale: °Optical rotation °Z International Sugar Scale % Concentration (g/mL, g/100mL, g/L) Measuring range: ± 360° / ± 259°Z ± 360° / ± 259°ZResolution: 0.01° / 0.05°Z 0.001° / 0.01°ZPrecision: ± 0.01° / ± 0.05°Z * ± 0.005° / ± 0.015°Z *Reproducibility: ± 0.01° / ± 0.05°Z ± 0.005° / ± 0.015°ZSensitivity: Up to OD 5Wavelength: request)Response time: ≤ 4 sMeasuring tubes: Di�erent models, 10 to 200 mm length, normal- and micro volume Material: glass, stainless steel, acid-proof stainless steel Stainless steel tubes with integrated temperature sensor*** Temperature measuring: NTC sensor for measurement of sample temperature Range: 0 - 99 °CResolution: 0.01°CPrecision: ± 0.03°CLight source: Display: 7“ TFT touchscreen, 800 x 480 Pixel, 16 bit coloursOperation: Touchscreen, keyboard**, mouse**, bar code reader**, remote via computer**Interface / Communication: RS232 (1x), USB A (4x), USB B (1x), Ethernet (1x), W-LAN/LAN**Standard models: Polartronic N 100 TOUCH: 589 nm Polartronic M 100 TOUCH: 589 nm Polartronic N 101 TOUCH: 882 nm Polartronic M 101 TOUCH: 882 nm Polartronic N 202 TOUCH: 589 + 882 nm Polartronic M 202 TOUCH: 589 + 882 nmConformity: International Pharmacopoea, OIML, ASTM, ICUMSA, Australian Standard K 157

* Standard conditions (20°C, 589 nm)** Optional

Instrumentación Científica S.A.Saavedra 1021 - Ciudad Autónoma de Buenos Aires - ArgentinaTel: (+54 11) 4308-5170 Líneas rotativaswww.icientifica.com