our future plans

15

Upload: nelly

Post on 10-Jan-2016

23 views

Category:

Documents


0 download

DESCRIPTION

Our Future Plans. Solar Cooker. At Barli…. Solar cooker in our school: The solar cooker costs Rs.70, 000. Solar Cookers can be effectively used for cooking Dal and Rice in our school. If we install solar Cookers we will be able to save 25 cylinders of LPG per month. Solar Water Heaters. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Our Future Plans
Page 2: Our Future Plans

Solar Cooker

Page 3: Our Future Plans

At Barli…

Page 4: Our Future Plans
Page 5: Our Future Plans

Solar cooker in our school:

The solar cooker costs Rs.70, 000. Solar Cookers can be effectively used for cooking Dal and Rice in our school. If we install solar Cookers we will be able to save 25 cylinders of LPG per month.

Page 6: Our Future Plans

Solar Water Heaters

Page 7: Our Future Plans

The cost for installing the solar water heater for Holkar house – 4.5 lakhThe cost for installing the solar water heater for Malwa house – 3.5 lakh = 8 lakh

(Additional 50 thousand is required for plumbing) that sums up to 8.5 lakh

Page 8: Our Future Plans

In Daly College there are 800 boarders. We worked out estimates for hot water required for bathing for two boarding houses which have a total of 300 students.

Each student / day requires 15 litre of hot water of 70ºC.

 

Electricity consumption → Q = MST

 

Where Q is in kilo calories

M = Mass (in Kg)

S = Specific heat of water = 1

T = ΔT it is the change in temperature.

ΔT for 70 ºC = 50ºC

 

Q = MST

= 15 X 1 X 50

= 750 kilo calories = 0.87225 kWh

For 300 students we will be saving energy/day = 0.87225 kWh X 300

= 261.675 kWh

 

For 300 students we will be saving energy/year (205 days approx) = 261.675 x 205 = 60,000 kWh

Page 9: Our Future Plans

Bio Gas Plant

Page 10: Our Future Plans
Page 11: Our Future Plans

Proposed Site….

Page 12: Our Future Plans

1 kg of food waste 250 gm of LPG

Waste produced per day

100 kg

Methane gas generation per day

25 kg (100 x 250 gm)

Total requirement is 60 kg of LPG per day

1/3rd of our LPG consumption

Page 13: Our Future Plans

Initiatives Electricity Units:-

CO2 emissions reduced

High Tension WiringLow Loss Type TransformerUnderground Power Cabling

23.040 MWh/year 46.080 MWh/year

14,592.94 lb

29,171.22lb

Solar Water Heating 60.000 MWh/year

38,000lb

Total 129.120MWh/year

81,764.16lb

What Difference our Initiatives will Bring

Total Money Saved in a Year= 129.12 x 5000= Rs 6,45,600

Page 14: Our Future Plans

Initiatives LPG Consumption is reduced by

Money Saved in a year

Solar Cooking

11.83 x 365 =4317.95 Kg/year

4317.95 x 23.3=

Rs 1,00,346

Biogas Digester

25 x 365 = 9125 Kg/year

9125 x 23.3 =

Rs 2,12,612

Total Money Saved in a year = Rs 3,12,612

Page 15: Our Future Plans