north elevation - oakville planning/sp-17290410201-elevat… · msai c7009 jan. 2017 proposed...
TRANSCRIPT
Retail Sign Retail Sign Retail Sign Retail SignRetail SignRetail Sign
Ground Floor
Second Floor
Third Floor
Fourth Floor
P1
54
00
32
00
32
00
123456789
HGFEDCBA
Ground Floor
Second Floor
Third Floor
Fourth Floor
P1
54
00
32
00
32
00
Roof
32
00
15
00
0
Roof
32
00
15
00
0
North Elevation
East Elevation
MASONRY FEATURESDESCRIPTION
GRAY STONE VENEER (ROUGH)
LIGHT GRAY STONE VENEER (SMOOTH)
REDDISH BROWN BRICK VENEER
WHITE COMPOSITE BOARD TRIM
COMPOSITE BOARD SIDING
ALUMINUM STOREFRONT WINDOW
ALUMINUM STOREFRONT DOOR
TRADITIONAL WINDOW
TRADITIONAL DOOR
ALUMINUM RAIL WITH GLASS
GOOSE NECK LIGHT
SCONCE LIGHT
FABRIC CANOPY
WHITE COMPOSITE CORNICE
STANDING SEEM METAL ROOFING
INSULATED OVERHEAD DOOR
** 'SP' DENOTES SPANDREL WINDOW
4
3
6
7
2
1
8
5
11
2
8
7
3
9
10
11
12
13
14
15
16
16
15
14
13
12
2
1
10
9
4
5
15
SP SP SP SP SP SP
SP SP SP SP SP SP
SP SP SP SP SP SP
All New Mech Units to be Less than 2m in height. All New Units to
be Screened as Outlined in Zoning By-Law with Prefinished Metal
Screens. Screen Colour to Match Cap Flashing.
Parapets Height Approx 450mm (not to exceed 2m)
Mech Penthouse Beyond
Mech Penthouse Beyond
2
1
4
3
10
9
14
8
Limiting Distance: 3.8m
Permitted %: 28.4%
EBF: 301 sm
Permitted Area of UO: 85.5sm
Proposed Area of UO:` 85.5sm
Proposed % of UO: 28.4%
Limiting Distance: 2.8m
Permitted %: 21.2%
EBF: 80 sm
Permitted Area of UO: 16.96 sm
Proposed Area of UO:` 16.5sm
Proposed % of UO: 20.6%
1:250
A201
FILE NO.
SHEET NO:
DATE:
SHEET TITLE:
CHECKED:
PROJECT NO.
DRAWN:
SCALE:
PROJECT:
CLIENT:
Succession
Development
Corporation
Oakville, Ontario
C7009
_____
msai
C7009
Jan. 2017
Proposed
Retirement Residence
2380 Lakeshore Road West
Oakville, Ont.
Proposed
Elevations
Ground Floor
Second Floor
Third Floor
Fourth Floor
P1
54
00
32
00
32
00
H G F E D C B A
Ground Floor
Second Floor
Third Floor
Fourth Floor
P1
54
00
32
00
32
00
2a 3a 4a 4b 5a 6a 7a
15
00
0
Roof
32
00
15
00
0
Roof
32
00
South Elevation
West Elevation
15
14
4
6
5
3
2
1
6
10
15
14
4
10
3
8
1
2
6
SP SPSP SP SPSP
SP SP SP SP SP SP
SP SP SP SP SP SP
SP SP SP SP SP SP
MASONRY FEATURESDESCRIPTION
GRAY STONE VENEER (ROUGH)
LIGHT GRAY STONE VENEER (SMOOTH)
REDDISH BROWN BRICK VENEER
WHITE COMPOSITE BOARD TRIM
COMPOSITE BOARD SIDING
ALUMINUM STOREFRONT WINDOW
ALUMINUM STOREFRONT DOOR
TRADITIONAL WINDOW
TRADITIONAL DOOR
ALUMINUM RAIL WITH GLASS
GOOSE NECK LIGHT
SCONCE LIGHT
FABRIC CANOPY
WHITE COMPOSITE CORNICE
STANDING SEEM METAL ROOFING
INSULATED OVERHEAD DOOR
** 'SP' DENOTES SPANDREL WINDOW
4
3
6
7
2
1
8
5
9
10
11
12
13
14
15
16
All New Mech Units to be Less than 2m in height. All New Units to
be Screened as Outlined in Zoning By-Law with Prefinished Metal
Screens. Screen Colour to Match Cap Flashing.
Parapets Height Approx 450mm (not to exceed 2m)
Mech Penthouse Beyond
Mech Penthouse Beyond
Limiting Distance: 5.7m
Permitted %: 40.0%
EBF: 486 sm
Permitted Area of UO: 194.4sm
Proposed Area of UO:` 172.5sm
Proposed % of UO: 35.3%
Limiting Distance: 4.9m
Permitted %: 39.0%
EBF: 137 sm
Permitted Area of UO: 53.4sm
Proposed Area of UO:` 46.5sm
Proposed % of UO: 34%
Limiting Distance: 4.0m
Permitted %: 30%
EBF: 317 sm
Permitted Area of UO: 95 sm
Proposed Area of UO:` 93 sm
Proposed % of UO: 29%
Limiting Distance: 5.5m
Permitted %: 40%
EBF: 460 sm
Permitted Area of UO: 184 sm
Proposed Area of UO:` 157.6 sm
Proposed % of UO: 34.2%
1:250
A202
FILE NO.
SHEET NO:
DATE:
SHEET TITLE:
CHECKED:
PROJECT NO.
DRAWN:
SCALE:
PROJECT:
CLIENT:
Succession
Development
Corporation
Oakville, Ontario
C7009
_____
msai
C7009
Jan. 2017
Proposed
Retirement Residence
2380 Lakeshore Road West
Oakville, Ont.
Proposed
Elevations