nemo outdoor training
TRANSCRIPT
Nemo Outdoor User Training
Nemo User Training Course Contents
• Nemo Outdoor_Indoor Basic Installation
• Hardware Configuration
• Nemo Outdoor Measurement Configuration
• Introduction to Graphical User Interface
• Nemo Outdoor Playback & File Formats
Nemo Outdoor_Indoor Installation
- Nemo Outdoor_Indoor License Option
- Basic SW Installation
Copy Protection• Nemo Outdoor uses either software or hardware
protection. (Indoor and Outdoor measurement are restricted by dongle options)
• Various available options are configured with each copy protection module.
Nemo Outdoor/Indoor Installation
Installation:
• You need to have local Administrator rights to install Nemo Outdoor
• Run the Nemo Outdoor setup.exe file and follow the instructions. Current Nemo Outdoor SW is 4.20.73 Check the latest versions of Nemo software from our web pages at (www.nemotechnologies.com) Valid to users with Technical Support Agreement only.
• Install DKU 2 cable driver.
• Restart laptop
HARDWARE SETUP
Testing Concept – Voice Call
• The voice testing environment consists of
– Nemo Outdoor compatible test measurement mobiles
– Laptop/Tablet PC with Nemo Outdoor installed
– Necessary connecting cables
– GPS receiver for Outdoor measurement
– (optional) fast frequency scanner.
Testing Concept – PS Data Call
• The PS data testing environment consists of Nemo Outdoor Application Server(e.g. FTP server, HTTP server, POP3 server, SMTP server, or WAP server)
Nemo Outdoor Measurement Configuration
• Nemo Outdoor supports manual and automated mode.
• Manual mode is based on the user establishing a data transfer connection or making voice calls.
- This mode is useful, when user wants to make a single continuous data transfer session or a voice call to monitor the resource allocation and cell reselection performance.
- This mode requires the user to control phones with Nemo Outdoor. The user should NOT use the mobile keyboard to establish voice calls or data calls.
• Automated mode is based on scripts that establish data transfer connections or voice calls on behalf of the user and can repeat the same or different sessions for a defined period of time. Scripts can be saved and edited. Script files can be, quickly and easily built with the Script Editor.
Manual / Automated Mode
Introduction to Graphical User Interface
Device Info:• ( )view disp parameters• ( )define displayed parameters• ( )configure notifications• ( )control phone• ( )configure measurement parameters
Device InfoConfiguration:
Measurement Properties
• Measurement properties for Voice Calls, Data calls etc. Need to be defined before the actual measurement
• Information on this tab should be filled in when doing Manual Measurement. (Press “Properties”)
• Voice Number defines the phone number to which voice calls will be made.
• Data Number defines the phone number for data calls, user name and password for service, etc.
• PDP Context Properties defines used APN for Packet data connection
• Data Protocol defines whether FTP or UDP is used for data transfer
• ICMP Ping Properties defines Ping settings, like Ping address and size of Ping data
Manual Measurement Configuration
Manual Measurement Control
• Measurement can be done from Mobile’s Control Panel or from Measurement menu by selecting the appropriate mobile
Automatic Measurement
• Measurements can be automatically repeated by predefined number of times
• Voice calls, data calls, attach, PDP activation, FTP, Web browsing, SMS, MMS, launch of external application, Ping sessions, etc. can be included in automatic measurement sequence
• Add / Modify / Delete / Move up / Move down / Append script / Repeat script value/ New /Open / Save / Save As...
• Script Editor/ Add / Voice Call• Voice Call Properties
– Number defines the number to be called
– Call Duration determines the time that the call lasts in seconds
– Call Attempt Timeout value determines the maximum duration of the call attempt. After that, the call attempt is considered to be failed.
Voice Call Script Configuration
• Access Point Name defines the APN used
• User Name/Password etc. Depend on operator’s settings
PS Script Configuration
Application Testing
• Host Name: IP address of the FTP server used.
• Username: username for the FTP server.
• Password: password for the FTP server.
• Passive Mode: Some firewalls may be configured to refuse any incoming connection requests, and in that case the data transfer would fail. With passive mode, the client always opens those new connections so the firewall does not block the connection.
• Direction: Receive – downloading; Send – uploading
• Remote File: File @ FTP Server
• Local File: File @ Testing laptop
PS Script Configuration
• URL: IP address of the test file that will be downloaded. For example, 203.125.58.120/1000kb.htm
• Local File: File @ Testing laptop
PS Script Configuration
• Editing PS Script
– Ping Test
– The ICMP (Internet Control Message Protocol) Ping functionality allows you to perform ping measurements simultaneously with FTP testing and data transfers
Script Configuration
Script Enhancements
• Possibility to synchronize scripts repeats between devices for benchmarking measurements.
• Improved wait function allows waiting for notifications during script measurements.
• Option to use measurement settings configured for manual testing during script measurements.
•By clicking the Notifications sheet, you can access the Notifications dialog box
•Select the Events that you would like to be notified of and also select whether the notification will be a textual note in the Output window, a sound (.wav file), or a bitmap
•Own notifications can be created for different situations, like bad quality example below, in Configuration tool
Event Trigger Notifications
User Defined Event Trigger Configuration I
• Static triggers
• User configurable event trigger
• Static triggers are made available in Nemo Outdoor by default and can collect statistics.
User Defined Event Trigger Configuration II
• Bitmap image Audio Wave Notification
• Event bitmap displayed in line graph
• (1.) Textual Notification displayed in the Output window
Event Trigger Configuration
• Event bitmap displayed in map window
• (2.) Sound Notification
Real-time monitoring during measurement
Real-time monitoring during measurement
Introduction to Nemo Outdoor Graphical User Interface
Introduction to Graphical User Interface
Introduction to Graphical User Interface
Status bar
Output window
Script Status window
Introduction to Graphical User Interface
Windows: Graphs
Line Graphs allow the user to accurately observe the measurement information.
• zoom• thresholds• scale• selectable parameters & values• selectable layers & values• average value presentation• displaying events & notifications
Workspace and Hardware Configuration
• By saving the workspace, different views can be saved to a .wor file. The following
views are saved to the file:
• Device Information Window views
• Grid and Graph views
• Color Set and Parameter selected in the Map Window (Map layers must be saved
to MapInfo .gst file)
• By saving the hardware configuration file, the information related to device(s) is
saved to the .hwc file:
• All information defined in the Measurement Properties Window
Introduction to Graphical User Interface
Windows: Graphs
Line graph Bar graph
Windows: Graphs Scatter plot
Scanning results
Introduction to Graphical User Interface
Introduction to Graphical User Interface
Windows: Grids
The user can easily select the events, parameters, and statistics to be displayed in the grid table. It is also possible to highlight certain events with color to improve the clarity of the results presented. Double-click on an event to view more information about that particular event.
Introduction to Graphical User Interface
Windows: Grids
Events
Parameters
Introduction to Graphical User Interface
Windows: Grids
Statistics
Layer3
Decoded Layer3
Introduction to Graphical User Interface
Textual Windows: Grids
Statistics
Layer3
Decoded Layer3
Events Parameters
Graphical Windows: Graphs
Scatter plot
Scanning Plots
Line graph
Bar graphTable
Nemo Indoor & Floor plan
• Nemo Indoor supports indoor floor plan in .tab; .bmp; .jpg; .tif formats.
Nemo Indoor & Floor plan
• During measurement, markers( ) need to be inserted in order to plot route on floor plan.
Nemo Indoor & Floor plan
• Indoor floor plan properties
Nemo Outdoor and MS BTS File
Multiple Real-time Route Coloring
• A line from the test vehicle to the serving and neighboring BTS can be drawn.
• New multi route feature allows users to compare easily measurements from different terminals on the same map or to correlate different parameters from the same terminal.
Playback in Nemo Outdoor
The Play button starts the playback
The Pause button pauses the playback
The Stop button stops the playback
Add Marker
Add Textual Note
Playback Speed
Files Used by Nemo Outdoor
Files Used by Nemo Outdoor
BTS files.bts, .nbf
MAP files MapInfo vector and raster maps
Result files.dt1, .dt2, .dt3, .dt4.fs1, fs1, fsn….ft1, ft2, ftn…
Workspace files .wor
Hardware configuration files.hwc
Script files.nsf
Nemo Outdoor Measurement File
• With Call mode measurements, *.DT1 file is produced.
• With Frequency/Pilot Scan (Separate Scanner) measurements , *.FS
file is produced.
• Open ASCII non-proprietary file format
• Easy to view and use
Nemo Outdoor Measurement File Contents
• Field strength results of the serving and neighbouring cells
• Quality class values
• Mobile output power level
• Layer 3, layer 2, RLC/MAC, LLC and RRC messages
• Geographical coordinates and time
• Call events and handover events
• Location update events
• Channel information
• Other information
Example of Nemo Outdoor Measurement File header
*** Nemo Outdoor 4.12.22 ff ver 1.72 28.01.2004 11:47:41
#ID Id tag for simultaneous measurement files : {342E0B9C-E2B5-495e-97AC-87D2B710A166}
#AG External antenna gain (dBi) : 0.00
#BF BTS filename :
#CF Call list filename : d:\Nemo Tools\deactivate.nsf
#CL External cable loss : 0.00
#CM Call mode : Originate
#HV Handler version : 4.01.12
#MF Map filename :
#MT Mobile type : T260
#NN Network name :
#NT Network type : GSM 900/GSM 1800
#PN Test call phone number :
#SW Device software version : af.7f.cb
#HW Device hardware version : 4C7
GAA 0.000000 0.000000 0 0 0 0 0 11:47:42.827
GAC 0.000000 0.000000 0 0 0 0 0 11:47:42.827 8
LUA 0.000000 0.000000 0 0 0 0 0 11:47:42.827
Questions?