Local PDS and Installation Model in ILC KEK Fukuda 2014/4/8 CFS-ADI Joint Meeting 1 Contents Common Local PDS in TDR Installation Model in XFEL What is the cost effective way to install PDS Mechanical concept of local PDS Supporting to cryomodule Transportation and Installation

Upload: alexandrina-wilkins

Post on 25-Dec-2015

217 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Local PDS and Installation Model in ILC KEK Fukuda 2014/4/8 CFS-ADI Joint Meeting 1 Contents Common Local PDS in TDR Installation Model in XFEL What is

Local PDS and Installation Model in ILC

KEK  Fukuda

2014/4/8 CFS-ADI Joint Meeting 1

Contents• Common Local PDS in TDR• Installation Model in XFEL• What is the cost effective way to install PDS• Mechanical concept of local PDS Supporting to cryomodule• Transportation and Installation

Page 2: Local PDS and Installation Model in ILC KEK Fukuda 2014/4/8 CFS-ADI Joint Meeting 1 Contents Common Local PDS in TDR Installation Model in XFEL What is

CFS-ADI Joint Meeting 2

Common Local PDS in TDR

2014/4/8

KCS

DKS

Page 3: Local PDS and Installation Model in ILC KEK Fukuda 2014/4/8 CFS-ADI Joint Meeting 1 Contents Common Local PDS in TDR Installation Model in XFEL What is

Installation Model in XFELLayout of Cryomodule with PDS in XFEL

2014/4/8 CFS-ADI Joint Meeting 3

Page 4: Local PDS and Installation Model in ILC KEK Fukuda 2014/4/8 CFS-ADI Joint Meeting 1 Contents Common Local PDS in TDR Installation Model in XFEL What is

What is the cost effective way to install PDS?

2014/4/8 CFS-ADI Joint Meeting 4

• Pre-installation of Local PDS at the another place makes us possible to pre-measure the low level RF and check/adjust the PDS with Cryomodule/Cavity System. Then increase of the reliability is expected.

• Bolting the flange at the sc tunnel results in involving the mistakes and imperfect connecting of waveguide system,   and results in high labor cost due to the work in the narrow space.

• PDS system in the independent supporting frame requires eight or nine connections between PDS and couplers and possible mistakes are not rejected.

• Therefore this model realizes cost effective and reliable installation.

Page 5: Local PDS and Installation Model in ILC KEK Fukuda 2014/4/8 CFS-ADI Joint Meeting 1 Contents Common Local PDS in TDR Installation Model in XFEL What is

PDS supporting system concept

2014/4/8 CFS-ADI Joint Meeting 5

Input Coupler Support x 9(8)Isolator Support X 9(8)

High power VTO x 2Input WG X 2

#1 Cryo

#2 Cryo

#3 Cryo

Page 6: Local PDS and Installation Model in ILC KEK Fukuda 2014/4/8 CFS-ADI Joint Meeting 1 Contents Common Local PDS in TDR Installation Model in XFEL What is

Transportation of Cryo-PDS Module

-Corridor Dimension-

2014/4/8 CFS-ADI Joint Meeting 6

Page 7: Local PDS and Installation Model in ILC KEK Fukuda 2014/4/8 CFS-ADI Joint Meeting 1 Contents Common Local PDS in TDR Installation Model in XFEL What is

Transportation of Cryo-PDS Module

2014/4/8 CFS-ADI Joint Meeting 7

In the first installation case, red circle area is empty.Keeping the area where man can escape during the transportation of replacing cryomdule when accident occurs.

Connection Work required

Page 8: Local PDS and Installation Model in ILC KEK Fukuda 2014/4/8 CFS-ADI Joint Meeting 1 Contents Common Local PDS in TDR Installation Model in XFEL What is

Installation of the Cryo-PDS Assembly

2014/4/8 CFS-ADI Joint Meeting 8

2~3 ideas for transportation of cryomodule-PDS Assembly • For two girders case, assembly on the carrier girder is carried by vehicle and shifted to locally fixed girder• Assembly on the girder system is carried by roller system

Page 9: Local PDS and Installation Model in ILC KEK Fukuda 2014/4/8 CFS-ADI Joint Meeting 1 Contents Common Local PDS in TDR Installation Model in XFEL What is

Application of this idea to KCS Single Tunnel (rough check of dimension)

2014/4/8 CFS-ADI Joint Meeting 9

Assembly without high-power VTO: Cryo having downstream WG after rectangularwindow

High-power VTO is Installed in tunnel

Page 10: Local PDS and Installation Model in ILC KEK Fukuda 2014/4/8 CFS-ADI Joint Meeting 1 Contents Common Local PDS in TDR Installation Model in XFEL What is

Summary

2014/4/8 CFS-ADI Joint Meeting 10

• Conceptual assembly which is useful to install are described. Local power distribution is holded by the cryomodule system, which has many advantages such as reliability and cost effectiveness.

• Transportation of this assembly and installation are considered.

• Real model should be manufactured and we (KEK) are planning to demonstrate this system.