pds-70mr 24v product guide - color · pdf file4 pds-70mr 24v product guide installation...
TRANSCRIPT
PDS-70mr 24VPower / data supply for MR LED lamps
PDS-70mr 24V Product Guide2
PDS-70mr 24V Power / data supply for MR LED lamps
• Universalpowerinputrange—PDS-70mr24Vaccommodatesinputvoltagesrangingfrom100–240VAC.Short-circuitprotectionpreventsdevicefailureduetoincorrectlywiredfixtures.
•Convenientinstallation—Multiplestandard-sizeconduitentriesaccommodate1/2in(13mm)and3/4in(19mm)UStrade-sizedconduit.
• Flexiblecontroloptions—YoucanusePDS-70mr24VDMXwithanyPhilipsColorKineticsDMXorthird-partycontroller,andPDS-70mr24VEthernetwithanyKiNET-compatibleEthernetcontroller.PDS-70mr24VPre-programmedfeaturesfourbuilt-invisualeffects,allowingconfigurationswithoutDMXorEthernetcontrollers.PDS-70mr24VPre-programmedcanfunctionasamastercontroller,deliveringdatatoadditionalpower/datasuppliesinarun.
PDS-70mr24Visapower/datasupplydesignedforLEDlightinginstallationsfeaturingMRLEDlampsfromPhilipsColorKinetics.PDS-70mr24Voutputsamaximumof72WinEthernet,DMX,andPre-programmedversions.
Rugged exterior-rated enclosureFeaturesaNEMA4(IP66)enclosureforinstallationinanydry,damp,orwetlocations.
PDS-70mr 24V Product Guide 3
UseItemNumberwhenorderinginNorthAmerica.
Overall Dimensions
8.3 in(211 mm)
1 in(25 mm)
MountingSlots
2 in(51 mm)
DM
X/ETH
ERNET
IN
DM
XO
UT
8.8 in224 mm
5.5 in140 mm
3.6 in91 mm
Sized for 1/2 in (13 mm) trade size conduit
Sized for 3/4 in (19 mm) trade size conduit
DM
X/ETH
ERNET
IN
DM
XO
UT
*KiNETistheEthernetlightingprotocolfromPhilipsColorKinetics.
Item Specification Details
Electrical
InputVoltage 100–240VAC,autosensing,50–60Hz
MaximumInputCurrent 1.7A
PowerOutput 24VDC,72Wmaximum
FuseRating (1)125V,4A,TypeF(fast-acting)fuse
Physical
Dimensions(Height x Width x Depth) 3.6x5.5x8.8in (91x140x224mm)
Weight 4.5lb (2.0kg)
Construction NEMA4enclosure,castaluminum,withslotsforsurfacemounting
Finish Powder-coatedgraymatte
Connectors
Data RJ-45inputandoutputconnectors
PowerOutput 2-pinterminalblockmainoutput2-pinscrewterminalauxiliaryoutput
PowerInput Line-neutral-groundcable,flyingleads
TemperatureRanges14°–104°F (-10°–40°C)Operating14°–122°F (-10°–50°C)Startup-40°–176°F (-40°–80°C)Storage
Humidity 0–95%,non-condensing
Cooling Convection
HeatDissipation 25%oftotalpowerinputatmaximumload
ControlDataInputSource
Pre-programmed Internal
DMXPhilipsColorKineticsfullrangeofDMXcontrollers,orcompatiblethird-partycontrollers.
EthernetPhilipsColorKineticsfullrangeofEthernetcontrollers,orKiNET-compatible*third-partycontrollers.
MaximumFixtureRunLength
14MRLEDlampsperdevice50ft(15.2m)maximumcablelength
CertificationandSafety
Certification UL/cUL,CE,PSE
Classification ULClass2powersupply
Environment Dry/Damp/WetLocation,IP66
SpecificationsDuetocontinuousimprovementsandinnovations,specificationsmaychangewithoutnotice.
Ordering InformationItem ItemNumber Philips12NC
PDS-70mr24VPre-programmed 109-000018-00 910503700098
PDS-70mr24VDMX 109-000018-01 910503700099
PDS-70mr24VEthernet 109-000018-02 910503700583
IncludedintheboxPDS-70mr24Vpower/datasupply(2)Spare125V,4A,TypeF(fast-acting)fuses(4)Sealingplugsandrings1/2NPT(4)Sealingplugsandrings3/4NPT(1)2-pinpanelmountterminalblock
Mounting Dimensions
PDS-70mr 24V Product Guide4
InstallationPDS-70mr24Visapower/datasupplydesignedforLEDlightinginstallationsfeaturingMRLEDlampsfromPhilipsColorKinetics.PDS-70mr24Voutputsamaximumof72WinEthernet,DMX,andPre-programmedversions.
Owner / User ResponsibilitiesItistheresponsibilityofthecontractor,installer,purchaser,owner,andusertoinstall,maintain,andoperatePDS-70mr24Vinsuchamannerastocomplywithallapplicablecodes,stateandlocallaws,ordinances,andregulations.Consultwiththeappropriateelectricalinspectortoensurecompliance.
Installing in Damp or Wet LocationsWheninstallingindamporwetlocations,sealalljunctionboxes,powersupplies,andotherdeviceswithelectronics-gradeRTVsiliconesealantsothatwaterormoisturecannotenteroraccumulateinanywiringcompartments,cables,fixtures,orotherelectricalparts.Youmustusesuitableoutdoor-ratedjunctionboxeswheninstallingindamporwetlocations.Additionally,youmustusegaskets,clamps,andotherpartsrequiredforinstallationtocomplywithallapplicablelocalandnationalcodes.
Plan the InstallationTostreamlineinstallationandensureaccurateconfiguration,startwithalayoutoralightingdesignplanthatshowsthephysicallayoutoftheinstallationandidentifiesthelocationsofalllightingfixtures,power/datasupplies,controllers,switches,andcables.
DMX ConfigurationsPDS-70mr24VDMXcanbeusedinDMXnetworks.DMXisappropriateforrelativelysimpleinstallations,orforinstallationsinwhichgroupsoflightsoperateinunison—forexample,foraccentlighting,perimeterlighting,orcovelightingapplications.
TypicalDMXinstallationsuseacontrollersuchasiPlayer3,aControllerKeypadforturningthelightingsystemonandoffandfortriggeringlightshows,andoneormorePDS-70mr24VDMXdevices.PDS-70mr24VDMXdevicescanbeconnectedinseriestodeliverDMXdatafromasinglecontrollertoallconnectedlights.
E Refer to the PDS-70mr 24V Installation Instructions for specific warning and caution statements.
100 – 240 VACController
Keypad
iPlayer 3Controller
MR LED Lamps
PDS-70mr 24V DMX
DMX DataSerial Cable
DMXInstallationwithiPlayer3
PDS-70mr 24V Product Guide 5
PDS-70mr24VPre-programmedversionscanbeusedinDMXenvironments.TheygenerateDMXcontroldatafromoneoffourpre-programmedlightingeffects.Youcanuseapre-programmeddeviceasamastercontrollertosendDMXcontroldatatoadditionalPDS-70mr24VDMXdevicesconnectedinseries.
Ethernet Configurations BecauseitisnotsubjecttotheDMXaddressinglimitations,Ethernetisthepreferredenvironmentforlarge-scale,color-changinglightshowsandvideodisplays,bothofwhichrequirelargenumbersofuniqueaddresses.
TypicalEthernetinstallationsuseanEthernetswitch,anEthernetcontrollersuchasLightSystemManager,EthernetControllerKeypadsforpush-buttonlightshowtriggering,andoneormorePDS-70mr24VEthernetdevices.ConnecteachPDS-70mr24VEthernetdevicetoanEthernetswitchport.
100 – 240 VAC
MR LED Lamps
PDS-70mr 24V Ethernet
Light System Manager
EthernetSwitch
Ethernet DataCat-5e Cable
Cat-5e Cable
To additional power / data suppliesor Ethernet switches (up to 3 levels)
EthernetInstallationwithLightSystemManager
DMXInstallationwithPre-programmedMaster
PDS-70mr 24VPre-programmed
PDS-70mr 24V DMX
MR LED Lamps
PDS-70mr 24V Product Guide6
Data and Power Run Length Maximums WhenselectingmountinglocationsforthePDS-70mr24Vdevicesinyourinstallation,keepthesedatarunlengthmaximumsinmind:
• InEthernetnetworks,maximumdatacableslengthsare328ft(100m)betweenEthernetdeviceswithoutarepeater(forexample,controllertoswitch,orswitchtoPDS-70mr24V).
• InDMXnetworks,maximumdatarunlengthsare1000ft(305m).ThemaximumnumberofPDS-70mr24Vdevicesthatcanbeconnectedinseriesis32.WerecommendusingDMXrepeatersfordatarunlengthsthatexceedthemaximumlength,aswellasforrunsofmorethan32PDS-70mr24Vdevicesconnectedinseries.
• EachPDS-70mr24Vdevicecansupportamaximumof14MRLEDlamps.Thefixturecablelengthcannotexceed50ft(15.2m).
Inspect PDS-70mr 24V and AccessoriesCarefullyinspecttheboxcontainingPDS-70mr24Vandthecontentsforanydamagethatmayhaveoccurredintransit.
Assemble Additional ItemsThefollowingadditionalitemsarerequiredtomountandconnectthePDS-70mr24V:
• 2+groundcopperwireforpowerconnections,asrequired
• CAT5eorbetterdatacable,asrequired
• Powerscrewdriver(formounting)
• Fourscrewssuitableforthemountingsurface
• Phillipsscrewdriver
• An8mmhexwrenchoradjustablewrench,anda5/16inhexwrench
• Electronics-gradeRTVsiliconeforinstallationsindampandwetlocations
• Cablestrainreliefandotherconnectorsasneeded(watertight,ifrequired)
• Wirestrippersandothertoolsasneeded
IncludedintheboxPDS-70mr24Vpower/datasupply(2)Spare125V,4A,TypeF(fast-acting)fuses(4)Sealingplugsandrings1/2NPT(4)Sealingplugsandrings3/4NPT(1)2-pinpanelmountterminalblock
PDS-70mr 24V 14 fixtures / 50 ft (15.2 m) maximum
Ethernetmaximumdatarunlength
PDS-70mr 24VController
328 ft (100 m) Maximum
Controller
1000 ft (305 m) Maximum
PDS-70mr 24V
1000 ft (305 m) Maximum
PDS-70mr 24V DMXPDS-70mr 24V Pre-programmed
DMXmaximumdatarunlength
PDS-70mr 24VController
328 ft (100 m) Maximum
Controller
1000 ft (305 m) Maximum
PDS-70mr 24V
1000 ft (305 m) Maximum
PDS-70mr 24V DMXPDS-70mr 24V Pre-programmed
PDS-70mr 24VController
328 ft (100 m) Maximum
Controller
1000 ft (305 m) Maximum
PDS-70mr 24V
1000 ft (305 m) Maximum
PDS-70mr 24V DMXPDS-70mr 24V Pre-programmed
PDS-70mr 24V Product Guide 7
E Make sure that there is adequate space to make all connections to the top and side of the device.
E Make sure that the device is securely attached and free of excessive vibration.
Mount PDS-70mr 24VMakesurepowerisOFFbeforemountingPDS-70mr24V.
1. PositionthePDS-70mr24Vinitsdesignatedmountinglocation.Makesurethemountinglocationisflat,suitableforthemountinghardware,andclearofdebrisandotherobstructions.
2. Usingfourscrewssuitableforthemountingsurface,securethePDS-70mr24Vtothesurfaceusingthemountingslotslocatedateachendofthedevice.
3. Identifywhichopeningstouseforpoweranddatacables.Usingtheappropriatehexwrenchoradjustablewrench,placetheincludedsealingplugsandringsintheunusedopenings.Makesurethatthesealingringsareseatedcorrectly.Useelectronics-gradeRTVsiliconeifinstallingindamporwetlocations.
4.Torquethesealingplugstoapproximately19in-lb(2.2Nm).
5. Installandtightencableconnectorsorconduittomanufacturer’sspecsintheremainingopenings.Donotovertighten.
8.8 in(224 mm)
8.3 in(211 mm)
5.5 in(140 mm)
3.6 in(91 mm)
.5 Ø NPT (13 mm)
.75 Ø NPT (19 mm)
5/16inHex
RTV Silicone
RTV Silicone
RTV Silicone
RTV Silicone
Linepowerin
Datain,power/dataout
PDS-70mr 24V Product Guide8
6. UsingaPhilipsscrewdriver,loosenthehousingcover’ssixscrewstoopenthePDS-70mr24Vhousing.
Make Data ConnectionsPDS-70mr24VDMXdeviceshavebothDMXinputandDMXoutputportsforconnectingdevicesinseries.ThefirstdeviceinaseriesreceivesinputfromaDMXcontroller,suchasiPlayer3.
PDS-70mr24VPre-programmedisalsoaDMXdevice,butitdoesnotreceiveinputfromaDMXcontroller.Instead,itgenerateslightshowdatausinganon-boardcontroller.PDS-70mr24VPre-programmedcanactasamasterdevicetopassdatadownstreamtoadditionalPDS-70mr24VDMXdevicesconnectedinseries.
PDS-70mr24VEthernetdevicehasanEthernetinputtoreceiveinputfromanEthernetcontroller,suchasLightSystemManager.UseanEthernetswitchorhubtoconnectthecontrollerandmultiplePDS-70mr24VEthernetdevices,
Data Connections: PDS-70mr 24V DMX
1. UsingaCAT5eorbettercable,connectyourcontroller’sDMXoutputporttotheDMXinputportinthefirstPDS-70mr24VDMXdeviceinaseries.
iPlayer 3Controller
PDS-70mr 24V DMX
MR LED Lamps
PDS-70mr 24V Product Guide 9
2. ToconnectPDS-70mr24VDMXdevicesinseries,connectaCAT5eorbettercablefromthefirstdevice’sDMXoutputporttotheDMXinputportinasecondPDS-70mr24VDMXdevice.Repeatasnecessary.YoucanconnectuptoDMX32devicesinserieswithoutarepeater.
Data Connections: PDS-70mr 24V Ethernet
UsingCAT5eorbettercable,connecttheEthernetinputportinthePDS-70mr24VtoanavailableportonanEthernetswitchconnectedtoyourlightingnetwork.Repeatasnecessary.
EthernetSwitch
PCPDS-70mr 24V Ethernet
MR LED Lamps
Light System Manager Controller
InfromController(DMX)
OuttonextPDS-70mr24VDMX
DM
X/ETH
ERNET
IND
MX
OU
T
DM
XO
UT
DM
X/ETH
ERNET
IN
First PDS-70mr 24V DMX Next PDS-70mr 24V DMX
DM
XO
UT
123OSM
DM
X/ETH
ERNET
IN
DM
X/ETH
ERNET
IND
MX
OU
T
DM
XO
UT
DM
X/ETH
ERNET
IN
First PDS-70mr 24V DMX Next PDS-70mr 24V DMX
DM
XO
UT
123OSM
DM
X/ETH
ERNET
IN
OuttonextPDS-70mr24VDMX
InfromPDS-70mr24VDMX
DMXin
DMXout
In from Controller
DM
XO
UT
DM
X/ETH
ERNET
IN
PDS-70mr 24V Ethernet
DM
XO
UT
123OSM
DM
X/ETH
ERNET
IN
InfromController(Ethernet)
Ethernetin
PDS-70mr 24V Product Guide10
Data Connections: PDS-70mr 24V Pre-programmed
PDS-70mr24VPre-programmeddevicesdonotacceptdataconnectionsfromexternalcontrollers.Instead,PDS-70mr24VPre-programmeddevicesactascontrollers,usingtheon-boardeffects.PDS-70mr24VPre-programmedbroadcastsDMXdatatoallconnectedMRLEDlamps.
Ininstallationswherethenumberoflampsrequiresmultiplepower/datasupplies,youcanuseaPDS-70mr24VPre-programmeddeviceasamastercontroller,andconnectmultiplePDS-70mr24VDMXdevicestoitinseries.ThePDS-70mr24VPre-programmedmasterbroadcastscontroldatadownstreamtoallconnectedPDS-70mr24VDMXdevices.
ToconnectPDS-70mr24VDMXdevicestoaPDS-70mr24VPre-programmeddeviceinseries,connectaCAT5eorbettercablefromthePDS-70mr24VPre-programmeddevice’sDMXoutputporttotheDMXinputportinaPDS-70mr24VDMXdevice.YoucanconnectadditionalPDS-70mr24VDMXdevicesinseriesusingtheirDMXoutputandinputports.Youcanconnectupto32DMXdevicesinserieswithoutarepeater.
PDS-70mr 24VPre-programmed
PDS-70mr 24V DMX
MR LED Lamps
DM
X/ETH
ERNET
IND
MX
OU
T
DM
XO
UT
DM
X/ETH
ERNET
IN
First PDS-70mr 24VPre-programmed
Next PDS-70mr 24V DMX
DM
XO
UT
123OSM
DM
X/ETH
ERNET
IN
DM
X/ETH
ERNET
IND
MX
OU
T
DM
XO
UT
DM
X/ETH
ERNET
IN
First PDS-70mr 24VPre-programmed
Next PDS-70mr 24V DMX
DM
XO
UT
123OSM
DM
X/ETH
ERNET
IN
OuttonextPDS-70mr24VDMX
InfromPDS-70MR24VPre-programmed OuttonextPDS-70mr24VDMX
PDS-70mr 24V Product Guide 11
Connect the PDS-70mr 24V to Line PowerMakesurepowerisOFFbeforeconnectingtolinepower.
1.Pullan8–18AWG(8.37–0.823mm2)strandedorsolidpowercablefromamainspowersourcetoaPDS-70mr24Vdevice.Stripatleast.38in(10mm)ofinsulationfromthewires.
2. PullthepowercablethroughoneofthepoweropeningsandintothepowerconnectionchamberinsidethePDS-70mr24Vhousing.Pullatleast6in(152mm)ofwireintothechamber.Ifnecesasry,useconduitasrequiredbylocalelectricalcodes.
3. Usingwirenuts,connectline,neutral,andgroundtothepower/datasupply’sflyingleads.
Connect Fixtures to the PDS-70mr 24VMakesurepowerisOFFbeforeconnectingfixtures.
1.Pulla14–18AWG(2.08–0.823mm2)strandedorsolid2-or3-conductorfixturecablefromanMR16lightingtrack,rail,orpendantthroughoneofthepower/dataoutopeningsonthesideofthePDS-70mr24Vhousing.
2. Usingasmallflatheadscrewdriver,loosenthetwocaptivescrewsonthefrontofthe2-pinpanelmountterminalblock.
3.Insertthefixturecablewiresintothe2-pinpanelmountterminalblock’swireentryslots.
4. Tightenthecaptivescrewsonthefrontofthe2-pinpanelmountterminalblock.
5. Insertthe2-pinpanelmountterminalblockintothefixtureoutputportinsidethePDS-70mr24Vhousing.
Linepowerin
DM
X/ETH
ERNET
IND
MX
OU
T
123OSM
UL / cUL
UL / cUL
LN
CE / PSE
CE / PSE UL / cULCE / CQC
LN
UL / cUL CE / PSEL
NL
N
L N
L N L N
L N
CE / PSECQC
L N
UL / cUL CE / CQCPSE
L N L N
UL / cUL CE / PSE
L N L N
L N
CE / PSE
L N
CE / CCC
L N
CE / Japan
L N
CE
L N
CE / PSE
L N
CE / PSECCC
L N
UL / cUL
UL / cUL
LN
CE / PSE
CE / PSE UL / cULCE / CQC
LN
UL / cUL CE / PSEL
NL
N
L N
L N L N
L N
CE / PSECQC
L N
UL / cUL CE / CQCPSE
L N L N
UL / cUL CE / PSE
L N L N
L N
CE / PSE
L N
CE / CCC
L N
CE / Japan
L N
CE
L N
CE / PSE
L N
CE / PSECCC
L N
DM
X/ETH
ERNET
IND
MX
OU
T
123OSM
Ground
E Each PDS-70mr 24V device can support a maximum of 14 MR LED lamps. The fixture cable length cannot exceed a total of 50 ft (15.2 m) per device.
PDS-70mr 24V Product Guide12
6.Ifusingagroundwire,attachittothegroundpostwithascrew.
Configure Effects (Pre-programmed Only)
PDS-70mr24VPre-programmedletsyoudisplayoneoffourconfigurableeffectsonlampswithoutacontroller.YouusethetoggleswitchandbuttonsinsidethePDS-70mr24VPre-programmedhousingtoselectaneffectandsetitsoptions,soyoumustconfigureyoureffectbeforeclosingandsealingthedevice.
AlthoughaPDS-70mr24VPre-programmeddevicecannotreceivesignalsfromanexternalcontroller,itcanactasamastercontroller,sendingDMXcontroldatadownstreamtoadditionalPDS-70mr24VDMXdevicesviaitsDMXOUTport.
MakesurethepowerisONbeforeconfiguringeffects.
1. LocatethetoggleswitchinsidethePDS-70mr24VPre-programmedhousing,andsettheswitchtoposition1.
DM
X/ETH
ERNET
IND
MX
OU
T
123OSM
Ground
DM
X/ETH
ERNET
IND
MX
OU
T
123OSM
123
E PDS-70mr 24V Pre-programmed effects are designed for use with iColor MR lamps. These effects can also work with iW MR lamps to create shows that use varying hues of white light. For iW MR lamp installations, the 2700 K color temperature maps to the red channel, 4000 K maps to the green channel, and 5700 K maps to the blue channel.
PDS-70mr 24V Product Guide 13
DM
X/ETH
ERNET
IND
MX
OU
T
123OSM
Options
SpeedM
ode
SOM
SOM
SOM
SOM
SOM
SOM SO
M
SOM
Rainbow
SOM
SOM
SOM
SOM
SOM SO
M
SOM
Random Color
SOM
SOM
SOM
SOM
SOM SO
M
SOM
Colorwash
SOM
SOM
SOM
SOM
FixedColor
SOM
SOM
SOM
SOM
2. LocatetheoptionbuttonsinsidethePDS-70mr24VPre-programmedhousing.
3. PresstheModebuttontocyclethroughtheeffects(Rainbow,RandomColor,Colorwash,FixedColor,inthatorder).
4. Onceyou’veselectedaneffect,usetheOptionsandSpeedbuttonstoconfiguretheeffect(refertothetablesbelowandonthefollowingpage).
ModeButton Description SpeedButton OptionsButton
Rainbow Producesasmoothtransitionthroughthecolorspectrum.Colorsappeartofolloweachotherfromfixturetofixture.
Cyclesthroughfoureffectspeedsettings Cyclesthroughfourpixelwidthsettings,thenreversesdirectionanddecreaseswidths
RandomColor Producesasequenceofrandomlygeneratedsolidcolorssimultaneouslyonallfixtures
Cyclesthroughfoureffectspeedsettings Togglesbetweensnapandfadetransitions
Colorwash Producesasmoothhuetransitiononallfixturessimultaneously,progressingthroughthecolorspectrum
Cyclesthroughfoureffectspeedsettings Reverseseffectdirection
FixedColor Displaysasolidcolor PressandholdtocyclethroughtheRGBcolorrange
—
Pre-programmed Effects
SOM SO
M
SOM
SOM SO
M
SOM
SOM SO
M
SOM
SOM SO
M
SOM
PDS-70mr 24V Product Guide14
SOM SO
M
SOM
SOM SO
M
SOM
SOM SO
M
SOM
SOM SO
M
SOM
SOM
SOM
SOM SO
M SOM SO
M
SOM
SOM
SOM SO
M SOM SO
M
SOM
SOM
SOM SO
M SOM SO
M
SOM SO
M
SOM
Rainbow
SOM SO
M
SOM
Random Color
SOM SO
M
SOM
Colorwash
FixedColor
SOM
SOM
SOM
SOM
Speed
Speed
Speed
Pixel width
Snap or fade transition
Direction
Pre-programmed Effect Speed and Other Options
PDS-70mr 24V Product Guide 15
Secure Connections and Cover1. Replacethecover,ensuringthatthegasketisseatedproperlyandthatnowires
arepinched.
2. Attachthecoverwiththesixincludedscrews.Tightenscrewsto8to10in-lbs(1Nm).
3. Ifinstallinginawetordamplocation,sealallscrewsandconnectionswithelectronics-gradeRTVsilicone.
E In wet or damp locations, use electronics-grade RTV silicone to seal all points of entry in all PDS-60 devices and all connected junction boxes to prevent water infiltration.
Copyright © 2013 Philips Solid-State Lighting Solutions, Inc. All rights reserved. Chromacore, Chromasic, CK, the CK logo, Color Kinetics, the Color Kinetics logo, ColorBlast, ColorBlaze, ColorBurst, ColorGraze, ColorPlay, ColorReach, iW Reach, eW Reach, DIMand, EssentialWhite, eW, iColor, iColor Cove, IntelliWhite, iW, iPlayer, Optibin, and Powercore are either registered trademarks or trademarks of Philips Solid-State Lighting Solutions, Inc. in the United States and / or other countries. All other brand or product names are trademarks or registered trademarks of their respective owners. Due to continuous improvements and innovations, specifications may change without notice.Cover Photo: Welcome Wall at Potawatomi Bingo Casino, Milwaukee, Wisconsin, USA, by Marty Peck, Creative Lighting Design & Engineering
Philips Color Kinetics3 Burlington Woods DriveBurlington, Massachusetts 01803 USATel 888.385.5742Tel 617.423.9999Fax 617.423.9998www.colorkinetics.com DAS-0000118-01 R01 09-13
Replacing the FusePDS-70mr24Visfusedtoprotectthedevicefromspikesincurrent.Alwaysreplaceablownfusewitha125V,4A,TypeF(fast-acting)fuse.
1. MakesurethatpowerisOFF.
2. UsingaPhillipsscrewdriver,unscrewthesixscrewsholdingthecoverinplace.
3. Removetheblownfusefromitsmetalclipsnexttothepoweranddatainputandoutputports.
4. Replacethefusewithanew125V,4A,TypeF(fast-acting)fuse.
5. Replacethecover,ensuringthatthegasketisseatedproperlyandthatnowiresarepinched.
6. Attachthecoverwiththesixincludedscrews.Tightenscrewsto8to10in-lbs(1Nm).
7. Ifinstallinginawetordamplocation,sealallscrewsandconnectionswithelectronics-gradeRTVsilicone.