In-Process Changes to USP <1211> Sterilization & Sterility Assurance of Compendial Articles James Agalloco Agalloco & Associates

Upload: jim-agalloco

Post on 10-May-2015

1.156 views

Category:

Technology


2 download

TRANSCRIPT

Page 1: Inprocess 1211

In-Process Changes to USP <1211> Sterilization & Sterility Assurance of Compendial Articles

James AgallocoAgalloco & Associates

Page 2: Inprocess 1211

DisclaimerThis presentation draws on in-process drafts currently in preparation within USP’s Microbiology Expert Committee.The interpretations and emphasis placed on subjects within this presentation are the author’s personal opinion and not official USP positions.The draft chapters that are issued by USP in Pharmacopeial Forum on these subjects differ somewhat from this presentation.

Page 3: Inprocess 1211

Who’s on the Micro Expert Committee?

James Akers, Ph.D., AK&A, ChairmanJames Agalloco, A&ADilip Ashtekar, Ph.D., Gilead SciencesAnthony Cundell, Ph.D., Merck & Co.Dennis Guilfoyle, Ph.D., FDA ORA liaisonRajesh Gupta, Ph.D., FDA CBER liaisonDavid Hussong, Ph.D., FDA CDER liaisonKaren McCullough, RMSRussell Madsen, TWGRanda Melhem, Ph.D. CBER liaisonJianghong Meng, Ph.D., University of Maryland,Leonard Mestrandrea, Ph.D., Mestrandrea LLCRainer Newman, Johnson & Johnson (retired)Mickey Parish, Ph.D., FDA CFSAN liaisonDonald Singer, GlaxoSmithKlineScott Sutton, Ph.D., Microbiology NetworkEdward Tidswell, Ph.D., BaxterRadha Tirumalai, Ph.D, USP Staff liaison

Page 4: Inprocess 1211

What’s Wrong?Despite the maturity of the subject, the practice of sterilization within the global healthcare industry has descended into rote repetition of wrong headed expectations.Regulatory obfuscation and industry apathy have caused all manner of unnecessary complications and added patient risks.Rather than making products safer, we may have actually increased patient risk!

Page 5: Inprocess 1211

Why did it go Wrong?We’ve largely ignored the core science that underlies all sterilization processes.We have relied on rote repetition of activities using overly simplistic models and ignored the core scientific principles upon which sterilization process must be constructed.If we haven’t made it sterilization any easier, we’ve sure made it dumber.

Page 6: Inprocess 1211

What are the Problems? - 1Failures to adequately sterilize.Aseptic processing where terminal sterilization could be used.Shortened expiration dates for products.Increased impurities, particles, extractables.Wasted energy costs and lost capacity due to over-processing.

Page 7: Inprocess 1211

What are the Problems? - 2Ignorance of the objectives.Oversimplification of key concepts.Inadequate training of industry.Confusion among disciplines.Excess caution built into protocols.Regulatory excess.Industry is risk averse to an extreme.Industry would rather switch than fight!

Page 8: Inprocess 1211

Sterilization Microbiology 101:

What you absolutely must know in only 5 slides!

Page 9: Inprocess 1211

What’s the Primary Objective?

A minimum PNSU of 10-6 is required.That means that in routine operation of the sterilizer, the possibility for a surviving bioburden microorganism must be less than 1 in 1,000,000.It has little to do with the biological indicator, and even less to do with the BI population.

Page 10: Inprocess 1211

106

103

100

10-3

10-6

10-9

10-15

10-12

10-18

3 6 12 15 18 21 24 27 309

Biological IndicatorDeath Curve

BioburdenDeath Curve

Po

pu

lati

on

Time

Microbial Death Curves

Here

Not Here

Page 11: Inprocess 1211

106

105

104

103

102

101

10-1

100

10-2

3 6 12 15 18 21 24 27 309

Biological Indicator

Death Curve

D value

1 log

Pop

ulat

ion

Time

D - Value

Page 12: Inprocess 1211

The D-ValueThe D-value is the time required to reduce a population of microorganisms by one log or a 90% reduction in count.A D-value is only meaningful if referenced to specified lethal conditions.For example D-values should always be referenced to a temperature, without that reference they have no meaning, i.e., moist heat D121.1°C or dry heat D170°C. For D-values in gases / liquids the agent concentration, RH and temperature must be indicated, i.e., D900 PPM, 75% RH,30°C

Page 13: Inprocess 1211

where: 

Nu = SAL / PNSU

D = D-value of the natural bioburdenF = F-value (lethality) of the processN0 = bioburden population

Calculation of PNSU (SAL)

Page 14: Inprocess 1211

What’s Been Missing?

Page 15: Inprocess 1211

Impact of Sterilization

A balance must be achieved between the need to maintain a safe, stable and efficacious product while providing sufficient lethality to attain a minimum level of sterility assurance.

Page 16: Inprocess 1211

The Forgotten ObjectiveAchieving sterility (aka minimum PNSU) is only half of what must be accomplished.In order to use the materials after the process their essential quality attributes have to be maintained.We can most definitely have too much of a good thing. If in the effort to kill microorganisms, we do lasting physical or chemical damage to the items being sterilized we have accomplished nothing of value.

Page 17: Inprocess 1211

Consequences of Over-processing

Reduce potencyIncreased degradation Increase in extractables / leachablesIncrease in particles – visible & sub-visibleLoss / weakening of package integrityAppearance changesChanges in physical propertiesLimited growth promotion (lab media)And most important of all – using an aseptic process instead of a terminal sterilization process.

Page 18: Inprocess 1211

What is USP’s Role?

Page 19: Inprocess 1211

USP’s General ChaptersUSP intends that General Chapters above 1000 will be entirely informational and will not contain monograph-related requirements. Topics that might be covered in informational chapters include: Background, theory, and future directions/applications Areas that need standards, e.g., nanotechnology Safety approaches and information Guidance chapters for good food and drug practices Drug development and registration documents Supply chain management documents, including GMP

analyses and comparisons Comparisons across the USP compendia.

General Chapter Management in the 2010–2015 Cycle, PF, Vol. 35, 5, Sept-Oct 2009

Page 20: Inprocess 1211

USP <1211> & Related Content

The core of this chapter dates to the 1980’s and the supportive elements were developed to address specific needs.The combined set of chapters is a patchwork quilt of somewhat disconnected ideas.Additionally, technological advances have made some of the content out of date.We did a quick fix in 2010 to fix the biggest problems and outlined a plan for a complete revision of all sterilization & sterility assurance related content.

Page 21: Inprocess 1211

<1211> The Planned Revision

Started Here: Sterilization at a more basic level: more instruction, less standardization

Individual chapters on each sterilization method: allows for easier revision.

Separate gas & vapor sterilization; Separate dry heat sterilization & depyrogenation; separate steam for parts and liquid filled containers; none of these are really the same process

New chapters on chemical sterilization: no prior information Aseptic processing as a separate chapter: not strictly a

sterilization subject; needs better connection to other supportive chapters

Update references throughout. New definitions for sterilization validation models. Clarify the role of the biological indicator. Clarify PNSU, SAL and risk to patient.

Integrate Endotoxin Indicator chapter as well as BI & CI content. Move BI monographs out of “official chapters”. Allow for easier development of other needed content in future. Depyrogenation treated independently of sterilization

Finished Here: Separation of Sterilization, Depyrogenation and Sterility Assurance content.

Page 22: Inprocess 1211

The Game PlanRevise the entire content, separating it for ease of development, review, approval and roll out.The current content will remain in place and be revised in piece meal fashion.Sterilization process specific content has been given priority, but supportive content revision is also underway.The first draft of chapters will appear in Pharmacopeial Forum beginning in 2012.

Page 23: Inprocess 1211

Old & New Structure Overview

<1211>Sterilization & Sterility Assurance of Compendial Articles will be divided into three major areas: <1211> General Concepts for Sterility Assurance

Aseptic Processing, Environmental Monitoring, Sterility Testing, Parametric Release, & other general sterility assurance related content

<1229> General Concepts for Sterilization Sterilization processes, BI, CI’s, other sterilization related

content <1228> General Concepts for Depyrogenation

Depyrogenation processes, EI’s, other related content

Work on <1211> section has been deferred because it is believed that sterilization & depyrogenation chapter revisions are more urgently needed.

Page 24: Inprocess 1211

What’s been completed so far

Page 25: Inprocess 1211

Where are we now?The planned structure is largely defined.We are working on multiple tracks Sterilization Process chapters – with most

used first Steam for Parts / Hard Goods Steam for Liquid Filled Containers Sterilizing Filtration Radiation Sterilization Gas Sterilization

Sterilization Support chapters beginning with Bioburden Monitoring Biological Indicators (starting soon)

Depyrogenation processes – starting soon & independent of the sterilization effort

Page 26: Inprocess 1211

<1229> Introductory Chapter

Provides an overview and introduces common elements related to all sterilization methods. Includes: Establishing & Justifying Sterilization

Processes D-value and Microbial Resistance Biological & Physical Data Sterilization Indicators & Integrators Selection of an Appropriate Method Routine Process Management

Page 27: Inprocess 1211

<1229> The Main Point“It is generally accepted that sterilized articles or devices purporting to be sterile attain a 10–6 microbial survivor probability, i.e., assurance of less than 1 chance in 1 million that viable bioburden microorganisms are present in the sterilized article or dosage form.”

Page 28: Inprocess 1211

Overkill Sterilization

106

103

100

10-3

10-6

10-9

10-15

10-12

10-18

3 6 12 15 18 21 24 27 309

Complete destruction of the

Biological Indicatorat this time point

Results in Overkill of the bioburden to the PNSU

where these line intersect

Po

pu

lati

on

Time

Page 29: Inprocess 1211

BB/BI with 106 BI Challenge

106

103

100

10-3

10-6

10-9

10-15

10-12

10-18

3 6 12 15 18 21 24 27 309

Partial destruction of the BI at this point

Destruction of the Bioburden where these lines intersect

Po

pu

lati

on

Time

PNSU

Page 30: Inprocess 1211

BB/BI with <106 BI Challenge

106

103

100

10-3

10-6

10-9

10-15

10-12

10-18

3 6 12 15 18 21 24 27 309

Complete destruction of the BI at this point

Destruction of the Bioburden where these lines intersect

Po

pu

lati

on

Time

PNSU

Page 31: Inprocess 1211

Bioburden Method

106

103

100

10-3

10-6

10-9

10-15

10-12

10-18

3 6 12 15 18 21 24 27 309

Complete destruction of the bioburden challenge

at this point

Destruction of the lot bioburden

where these lines intersect

Po

pu

lati

on

Time

PNSU

Page 32: Inprocess 1211

Steam Sterilization

Page 33: Inprocess 1211

<1229S> Direct Steam Sterilization

Separated prior sub-chapter into parts <1229S> and liquids <1229A> to allow for differences, and greater clarity. “overkill approach” is the method of choice.Separates processes where over-processing is not a concern from those where it is.In theory parts sterilization has no upper limit, while terminal / liquid sterilization is bounded both above and below the desired process.

Page 34: Inprocess 1211

Parts vs. Liquid Sterilization

Non-Sterile

Sterile

SterileStable

SterileNon-Stable

Product Quality Attributes Product Quality Attributes Non-issue - Overkill MethodNon-issue - Overkill Method

Non-SterileStable

Heat Input

Product Quality Attributes Product Quality Attributes An issue – BB/BI MethodAn issue – BB/BI Method

1229A1229S

Dir

ect

Heat

to

Su

rface

Ind

irect

heat

via

con

tain

er

wall

Page 35: Inprocess 1211

<1229A> Steam Sterilization of Aqueous Liquids

The method of choice for liquid parenteral products, and similar processes are utilized for laboratory media and process intermediates.“Where the overkill approach can be utilized for terminal sterilization of sealed liquid containers, it is the preferred approach.”“a dual set of requirements is established for nearly every important processing parameter. Sterilization time-temperature or F0 conditions will include both lower (sterility related) and upper (stability related) limits to simultaneously assure safety and efficacy of the processed materials.”

Page 36: Inprocess 1211

<1229A> Steam Sterilization of Aqueous Liquids

Terminal sterilization of products High/Low F0, variety of BI’s, Overkill & BB/BI

methodMedia for laboratory usage High/Low F0, Overkill & BB/BI method, BI

usage? - self indicating?Intermediates / process aidesHigh/Low F0, BI usage, Overkill & BB/BI method

Laboratory and production bio-wasteLow F0, G. stearothermophilus, Overkill method, condensate collection / kill

Page 37: Inprocess 1211

<1229A> Steam Sterilization of Aqueous Liquids

Probability of a Non-Sterile Unit (PNSU)

WhereNu = Probability of a Non-Sterile Unit

D = D-value of the natural bioburdenF = F-value of the processN0 = bioburden population per container

Validation Routine Usage

F0 = 8.0 minutes F0 = 8.0 minutes

D121 of BI = 0.5 minutes D121 of bioburden = 0.005 minutes

N0 of BI = 106 N0 of bioburden = 100 ( or 102)

PNSU for BI = 10-10 PNSU for Bioburden = 10-1,598

Page 38: Inprocess 1211

Sterilization by Filtration

Page 39: Inprocess 1211

Sterilization by Filtration Draft

Sterilizing filtration is a retentive process, not a destructive one.Physical removal of microorganisms depends on the upstream bioburden, the properties of the solution, the filtration conditions and the filter itself.Can be validated to consistently yield solutions that are sterile as defined in <1229>.

Page 40: Inprocess 1211

Sterilization by Filtration - 1Definition and description of “sterilizing-grade filter”Retention mechanisms and factors affecting retention Nature of “pores” and microorganisms Composition and structure of filter matrix Composition of filtered solution Filtration conditionsFilter efficacy Log-reduction value

Page 41: Inprocess 1211

Sterilization by Filtration - 2ValidationIntegrity test principles and methods Bubble point Diffusive flow Pressure holdPre- and post-filtration and sterilization integrity testingThe need for pre-filtration bioburden controlTroubleshooting common filtration problems

Page 42: Inprocess 1211

Radiation Sterilization

Page 43: Inprocess 1211

<1229R> Radiation Sterilization

“The prevalent radiation usage is either gamma rays or electron beams. Other methods utilize x-rays, microwaves and visible light. The impact of radiation on materials can be substantial and is a major consideration in the selection of radiation as a processing method.”“Radiation sterilization is unique in that the basis of control … is the absorbed radiation dose, which can be precisely measured. Dose setting and dose substantiation procedures are used to validate the radiation dose required to achieve sterility assurance level.”

Page 44: Inprocess 1211

<1229R> Radiation Sterilization

The use of BI’s in radiation sterilization is not necessary: Non-spore-formers have been identified as

more resistant than B. pumilus. Dose measurement is accurate and has been

closely correlated to microbial destruction.The dose setting methods of AAMI/ISO are well established and easily adapted to pharmaceutical applications. VDmax has been utilized for terminal sterilization of several pharmaceutical preparations.

Page 45: Inprocess 1211

VDMAX – Example 1

Page 46: Inprocess 1211

VDMAX – Example 2

Page 47: Inprocess 1211

Gas, Liquid & Vapor SterilizationSimilar but not the same

Page 48: Inprocess 1211

Gas, Liquid & Vapors - D-Values

A D-value is only meaningful if referenced to specified lethal conditions. For example wet or dry heat D-values should always be referenced to a temperature, without that reference they have no meaning, i.e., D121.1°C or D170°C.

For D-values in gases / liquids the agent concentration, RH and temperature must be indicated, i.e., D900 PPM, 75% RH, 30°C

D-values cannot be accurately determined for vapors.

Page 49: Inprocess 1211

<1229G> Gas SterilizationApplicable to single phase gaseous processes only. Condensation of the agent is not a

consideration in the execution of these processes.

Ethylene oxide – model for all systems Chlorine dioxide OzoneTwo validation approaches defined Traditional half-cycle method Bracketing method – variations in

concentration, relative humidity and temperature. More efficient & more scientific as well.

Page 50: Inprocess 1211

106

103

100

10-3

10-6

10-9

10-15

10-12

10-18

3 6 12 15 18 21 24 27 309

Po

pu

lati

on

Time

Half CycleKill of

Bioburden

Half CycleKill of

Bioindicator

Full Cycle

Half Cycle

Half Cycle ApproachDeath Curves

Page 51: Inprocess 1211

106

103

100

10-3

10-6

10-9

10-15

10-12

10-18

3 6 12 15 18 21 24 27 309

Po

pu

lati

on

Time

routine sterilization cycle

Bracketing ApproachDeath Curves

“worst case” sterilization cycle

“worst case” m

aterials cycle

X

X

X

Validation Cycles

RoutineProcess

Page 52: Inprocess 1211

<1229L> Liquid SterilizationChemical Sterilants in aqueous solutions Aldehydes – CH2O, CH3CHO, etc. Acids – HNO3, H2SO4, peracetic, etc. Bases – NaOH, KOH, etc. Oxygenating compounds – H2O2, O3, ClO2, etc. Halides – NaOCl, Cl2, etc.

Must include an aseptic post-cycle quench step to stop process prior to adverse material impact.Validation like gas sterilization. The phase is different but the same parameters apply.

Page 53: Inprocess 1211

Gas/Liquid vs. Vapor Sterilization

Gases are more penetrating, liquids more uniform in concentration, and both are less subject to variations in temperature and relative humidity.Vapors will have different concentrations in each phase. When a vapor has 2 possible condensable components it is even more difficult to predict conditions anywhere.

Page 54: Inprocess 1211

<1229V> Vapor SterilizationIntended for condensing vapor systems (gas and liquid phases present simultaneously) Hydrogen Peroxide Peracetic Acid

The presence of multiple phases simultaneously complicates concentration determination at the point of sterilization.D-value determination is problematic because of difficulties with parameter measurement in a multi-component 2 phase system.Approaches for validation are a hybrid of the liquid and gas sterilization methods.

Page 55: Inprocess 1211

<1229V> Vapor SterilizationThe kill rates in the gas and liquid phase are different reflecting the different concentrations and moisture present in each phase.The conditions within a vapor system are unlikely to be constant & uniform because the agent supply is at a higher temperature than the chamber.The conditions at any location may change during the course of the process.Reproducible kill is possible despite all of the complication because the agent is lethal in both phases; It’s more complex than any of the other methods.

Page 56: Inprocess 1211

<1229V> Vapor SterilizationTwo validation approaches can be utilized, with the only supportive evidence derived from microbial destruction. Traditional half-cycle method Bracketing method

The linearity of microbial destruction cannot be assured as the process conditions may not be completely homogeneous.The efficacy of the agents used should assure sterilization, however we do not have the ability to predict the outcome because the process parameters may vary substantially across the chamber.

Page 57: Inprocess 1211

106

103

100

10-3

10-6

10-9

10-15

10-12

10-18

3 6 12 15 18 21 24 27 309

Po

pu

lati

on

Time

Bi-Phasic Kill Possibilities

Gas PhaseThroughout

Liquid PhaseThroughout

Gas Phase EarlyLiquid Phase Late

Liquid Phase EarlyGas Phase Late

The difference in kill rates Is unknown

Page 58: Inprocess 1211

106

103

100

10-3

10-6

10-9

10-15

10-12

10-18

3 6 12 15 18 21 24 27 309

Po

pu

lati

on

Time

“worst case” m

aterials cycle

Bi-Phasic Death Curves

Gas Phase Death Curve

Liquid Phase Death Curve

Composite Death Curve

Page 59: Inprocess 1211

106

103

100

10-3

10-6

10-9

10-15

10-12

10-18

3 6 12 15 18 21 24 27 309

Po

pu

lati

on

Time

routine sterilization cycle

“worst case” m

aterials cycle

Vapor ProcessBracketing Approach

Death Curves

“worst case” sterilization cycle

“worst case” m

aterials cycle routine sterilization cycle

X

X

Validation Cycles

RoutineProcess

X

Page 60: Inprocess 1211

Dry Heat Sterilization

Page 61: Inprocess 1211

<1229H> Dry Heat Sterilization

Distinction has been made between dry heat sterilization and depyrogenation because of major process differences. Dry heat sterilization: Is almost always performed in ovens in a batch

process. Uses a biological indicator B. atrophaeus. Is usually in the 160-180°C temperature range. A reasonable mathematical correlation between

physical data and microbial effect exists.Physical requirements are less definitive than for steam processes, but still apply.Dry heat depyrogenation will be in a separate chapter.

Page 62: Inprocess 1211

<1229> Bioburden Monitoring

Reviews the relevant concerns for bioburden content Ability to survive the process Population Risk to Public HealthConsiders patient & product impact Provides a decision tree for use in establishment of a monitoring program.

Page 63: Inprocess 1211
Page 64: Inprocess 1211

Depyrogenation

Page 65: Inprocess 1211

<1228> Depyrogenation Methods

<1228D> – Dry Heat Depyrogenation<1228C> – Chemical Depyrogenation<1228F> – Depyrogenation by Filtration<1228P> – Depyrogenation by Physical Means

All of these need integration with endotoxin indicator and testing chapters.

Page 66: Inprocess 1211

<1228D> Dry Heat Depyrogenation

Differs from dry heat sterilization in several ways:Dry heat depyrogenation: Predominantly utilized for glass and stainless

steel items. Batch and continuous processes are in use. An endotoxin monograph has been completed

and will be inserted within the overall <1228> revision.

Usually in the >200-300°C temperature range. Mathematical correlation between physical data

and microbial effect is extremely poor. Defined physical parameters have proven problematic.

Endotoxin destruction is the primary goal.

Page 67: Inprocess 1211

<1229?> Biological Indicators

Major changes are anticipated for USP’s existing biological indicator content.Bring together in one comprehensive chapter the content currently found in: <1211> Sterilization & Sterility Assurance of

Compendial Items <1035> Biological Indicators for Sterilization <55> Biological Indicators —Resistance

Performance Tests

And

Page 68: Inprocess 1211

<1229?> BI Monographs Biological Indicator for Dry-Heat Sterilization,

Paper Carrier Biological Indicator for Ethylene Oxide

Sterilization, Paper Carrier Biological Indicator for Steam Sterilization,

Paper Carrier Biological Indicator for Steam Sterilization, Self-

Contained Biological Indicators for Moist Heat, Dry Heat,

and Gaseous Modes of Sterilization, Liquid Spore Suspensions

Biological Indicators for Moist Heat, Dry Heat, and Gaseous Modes of Sterilization, Nonpaper Carriers

Page 69: Inprocess 1211

The Rest of the Story

Page 70: Inprocess 1211

Old & New Structure Overview

<1211> Existing Sterilization & Sterility Assurance of Compendial Articles will be divided into three major areas: <1211> General Concepts for Sterility

Assurance Aseptic Processing, Environmental Monitoring,

Sterility Testing, Parametric Release, & other general sterility assurance related content

<1229> General Concepts for Sterilization Sterilization processes, BI, CI’s, other sterilization

related content <1228> General Concepts for Depyrogenation

Depyrogenation processes, EI’s, other related content

Page 71: Inprocess 1211

<1211> Introductory ChapterGeneral Concepts for Sterility AssuranceAddress the relationship between sterility, and sterilization, tying in sterilization, aseptic processing, environmental monitoring and sterility testing to provide greater clarity.

Sterilization process controls -> sterility (terminally sterilized products)

Sterilization process controls (multiple processes) -> aseptic processing / environmental monitoring -> sterility (aseptically produced products)

Page 72: Inprocess 1211

Planned New Chapters in 1211?

Revised content on aseptic processing (currently in 1211, but minimally detailed). Needs linkage to revised <1116> Microbiological Control and Monitoring of Aseptic Processing Environments.New content necessary on the use of RABS & isolators for aseptic processing.

Page 73: Inprocess 1211

<1222> Parametric Release of TS

Aligns the guidance with global regulatory expectations.Must be aligned with <1229>,<1229T>, <1229G>,<1211H> and <1229R> as these chapters evolve because all of these sterilization chapters are relevant for parametric release.

Page 74: Inprocess 1211

Planned New Chapters in 1211?

1211T – Terminal sterilization perspectives covering all process types (combination with 1222 is possible).1211P – Post Aseptic Fill adjunct treatment using either radiation or moist heat.Integrate <1207> Container-closure integrity with possible new content in <1211> and <1229>. Microbiology Expert Committee members are involved with the <1207> revision.

Page 75: Inprocess 1211

bedanktbedankt tesekkürletesekkürle

Ευχαριστώ Ευχαριστώ takk takk

DziękujęDziękuję

ShukriyâShukriyâ kiitoskiitos

aitähaitäh

tacktack

DDankeankeObrigadaObrigada

GrazieGrazie

Muchas graciasMuchas gracias

mange takmange tak

díkydíky tack så mycket tack så mycket Thank you

köszi köszi

hvalahvala

ĎakujemĎakujem

شكشكا �اًر �ًر

תודהתודהСпасибоСпасибо

MulţumescMulţumesc

Thank yuThank yu

salamatsalamat

faleminderitfaleminderit

děkuji vamděkuji vam

nandrinandri

ДякуюДякую

köszönömköszönömanugurihiitosumianugurihiitosumi

dhanya-waaddhanya-waad

dhanya-waaddhanya-waad

go raibh go raibh maith agatmaith agat

MerciMerci

ačiûačiû Terima Kasih

Many Many THANKSTHANKS for for YOURYOUR Attention Attention