ibm system storage n series gateway implementation guide

63
IBM System Storage N series Gateway Implementation Guide For Third-Party Storage GA32-1050-02

Upload: others

Post on 15-Oct-2021

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: IBM System Storage N series Gateway Implementation Guide

IBM System Storage N series

Gateway Implementation Guide ForThird-Party Storage

GA32-1050-02

���

Page 2: IBM System Storage N series Gateway Implementation Guide
Page 3: IBM System Storage N series Gateway Implementation Guide

Contents

Preface ........................................................................................................... 7Supported features ....................................................................................................... 7Websites ...................................................................................................................... 7Getting information, help, and service ........................................................................ 7Before you call ............................................................................................................ 8Using the documentation ............................................................................................. 8Hardware service and support ..................................................................................... 8Firmware updates ........................................................................................................ 9How to send your comments ....................................................................................... 9

Understanding gateway and third-party storage implementation ........ 10EMC CLARiiON and VNX storage arrays ............................................. 12

Requirements for configuring EMC CLARiiON and VNX arrays with gateways ... 12Required host configuration parameters ....................................................... 12

General configuration guidelines .............................................................................. 12How EMC CLARiiON and VNX storage arrays control access to data ....... 13Requirement for 8 Gb array port initialization .............................................. 13EMC CLARiiON storage array families ....................................................... 13EMC VNX storage array families ................................................................. 14

Supported configurations for EMC CLARiiON and VNX arrays ............................ 14Stand-alone basic configuration .................................................................... 14Single 4-port array LUN group ..................................................................... 15Stand-alone with two 2-port LUN groups ..................................................... 16

EMC Symmetrix storage arrays ............................................................... 17Requirements for configuring EMC Symmetrix arrays with gateways .................... 17

Required host channel director port configuration parameters ..................... 17Required host configuration parameters ....................................................... 17

General configuration guidelines .............................................................................. 18Requirements for implementing LUN security ............................................. 18Caution about using the VCMDB LUN ........................................................ 18Caution about using the ACLX LUN ............................................................ 19Restriction on using a gatekeeper LUN ........................................................ 19EMC Symmetrix storage array families ........................................................ 19

Table of Contents | 3

Page 4: IBM System Storage N series Gateway Implementation Guide

Supported configurations for EMC Symmetrix arrays ............................................. 19Stand-alone basic configuration .................................................................... 19Stand-alone with two 2-port LUN groups ..................................................... 20Two 4-port array LUN groups ...................................................................... 21

Fujitsu ETERNUS storage arrays ............................................................ 22Requirements for configuring Fujitsu ETERNUS arrays with gateways ................. 22

Requirement for creating a host response pattern for Fujitsu storagearrays ....................................................................................................... 22

Required host configuration parameters for DX8xxx arrays ........................ 22Required host configuration parameters for DX4xx arrays .......................... 23

General configuration guidelines .............................................................................. 24Fujitsu ETERNUS storage array families ..................................................... 24

Supported configurations for Fujitsu ETERNUS arrays ........................................... 24Stand-alone basic configuration .................................................................... 24Single 4-port array LUN group ..................................................................... 25Two 2-port array LUN groups ...................................................................... 25Two 4-port array LUN groups ...................................................................... 26

Hitachi Data Systems storage arrays ........................................................ 28Requirements for configuring Hitachi Data Systems arrays with gateways ............. 28

Required system parameter for NSC55, USP, and VSP arrays .................... 28Required system parameters for AMS arrays ............................................... 28

General configuration guidelines .............................................................................. 29Requirements for creating LUNs in dynamic pools ...................................... 29Requirements for formatting array LUNs on Hitachi arrays ......................... 29Requirements for using disks external to the array ....................................... 29Hitachi Data Systems storage array families ................................................. 30

Supported configurations for Hitachi Data Systems storage arrays .......................... 30Stand-alone basic configuration .................................................................... 30Stand-alone with two 2-port LUN groups ..................................................... 31Single 4-port array LUN group ..................................................................... 32Two-port direct-attached stand-alone configuration ..................................... 32Four-port direct-attached HA pair configuration .......................................... 33

HP EVA storage arrays ............................................................................. 34Requirements for configuring HP EVA arrays with gateways ................................. 34

Required system parameters for HP EVA arrays .......................................... 34General configuration guidelines .............................................................................. 34

4 | Gateway Implementation Guide for Third-Party Storage

Page 5: IBM System Storage N series Gateway Implementation Guide

Requirements for configuring multiple LUN groups .................................... 34Requirements for configuring the HP EVA Storage Management Server ... 35HP EVA storage array families ..................................................................... 35

Supported configurations for HP EVA arrays ........................................................... 35Stand-alone with two 2-port LUN groups ..................................................... 36Two 4-port array LUN groups ...................................................................... 36

HP XP storage arrays ................................................................................. 38Requirements for configuring HP XP arrays with gateways .................................... 38

Required system parameter for all HP XP models ........................................ 38General configuration guidelines .............................................................................. 38

Requirements for using disks external to the array ....................................... 38Requirements for configuring ports .............................................................. 39HP XP storage array families ........................................................................ 39

Supported configurations for HP XP arrays .............................................................. 39Stand-alone basic configuration .................................................................... 39Stand-alone with two 2-port LUN groups ..................................................... 40Two-port direct-attached stand-alone configuration ..................................... 41Four-port direct-attached HA pair configuration .......................................... 41

IBM DS storage arrays .............................................................................. 43Requirements for configuring IBM DS arrays with the gateway .............................. 43

Required host type for DS8xxx arrays .......................................................... 43Required host type for DS3950 DS4xxx and DS5xxx arrays ....................... 43Requirements for configuring DS8300 9A2 LPAR models .......................... 43

General configuration guidelines .............................................................................. 43Requirements for volume groups on DS8xxx storage arrays ........................ 44Requirements for multiple LUN groups on all IBM DS arrays .................... 44Requirements for direct-attached configurations with all IBM DS arrays .... 44IBM DS storage array families ...................................................................... 44

Supported configurations for IBM DS arrays ........................................................... 45Stand-alone basic configuration .................................................................... 45Two 2-port array LUN groups ...................................................................... 46Single 4-port array LUN group ..................................................................... 47Two 4-port array LUN groups ...................................................................... 48Two-port direct-attached stand-alone configuration ..................................... 49Four-port direct-attached HA pair configuration .......................................... 50

IBM XIV storage arrays ............................................................................ 51

Table of Contents | 5

Page 6: IBM System Storage N series Gateway Implementation Guide

Requirements for configuring IBM XIV arrays with gateways ................................ 51Required system parameters for IBM XIV arrays ........................................ 51

Supported configurations for IBM XIV arrays ......................................................... 51Single 4-port array LUN group ..................................................................... 51

3PAR storage arrays .................................................................................. 53Requirements for configuring 3PAR arrays with gateways ...................................... 53

Required system parameters for 3PAR arrays .............................................. 53General configuration guidelines .............................................................................. 53

3PAR storage array families ......................................................................... 53Supported configurations for 3PAR arrays ............................................................... 54

Single 4-port array LUN group ..................................................................... 54Two-port direct-attached stand-alone configuration ..................................... 55

Copyright information ............................................................................... 56Trademark information ............................................................................. 57Index ............................................................................................................. 60

6 | Gateway Implementation Guide for Third-Party Storage

Page 7: IBM System Storage N series Gateway Implementation Guide

Preface

Supported featuresIBM System Storage N series storage systems are driven by NetApp Data ONTAP software. Somefeatures described in the product software documentation are neither offered nor supported by IBM.Please contact your local IBM representative or reseller for further details.

Information about supported features can also be found on the N series support website (accessed andnavigated as described in Websites on page 7).

WebsitesIBM maintains pages on the World Wide Web where you can get the latest technical information anddownload device drivers and updates. The following web pages provide N series information:• A listing of currently available N series products and features can be found at the following web

page:www.ibm.com/storage/nas/

• The IBM System Storage N series support website requires users to register in order to obtainaccess to N series support content on the web. To understand how the N series support webcontent is organized and navigated, and to access the N series support website, refer to thefollowing publicly accessible web page:www.ibm.com/storage/support/nseries/This web page also provides links to AutoSupport information as well as other important N seriesproduct resources.

• IBM System Storage N series products attach to a variety of servers and operating systems. Todetermine the latest supported attachments, go to the IBM N series interoperability matrix at thefollowing web page:www.ibm.com/systems/storage/network/interophome.html

• For the latest N series hardware product documentation, including planning, installation andsetup, and hardware monitoring, service and diagnostics, see the IBM N series InformationCenter at the following web page:publib.boulder.ibm.com/infocenter/nasinfo/nseries/index.jsp

Getting information, help, and serviceIf you need help, service, or technical assistance or just want more information about IBM products,you will find a wide variety of sources available from IBM to assist you. This section contains

7

Page 8: IBM System Storage N series Gateway Implementation Guide

information about where to go for additional information about IBM and IBM products, what to do ifyou experience a problem with your IBM N series product, and whom to call for service, if it isnecessary.

Before you callBefore you call, make sure you have taken these steps to try to solve the problem yourself:

• Check all cables to make sure they are connected.• Check the power switches to make sure the system is turned on.• Use the troubleshooting information in your system documentation and use the diagnostic tools

that come with your system.• Refer to the N series support website (accessed and navigated as described in Websites on page 7)

for information on known problems and limitations.

Using the documentationThe latest versions of N series software documentation, including Data ONTAP and other softwareproducts, are available on the N series support website (accessed and navigated as described in Websites on page 7).

Current N series hardware product documentation is shipped with your hardware product in printeddocuments or as PDF files on a documentation CD. For the latest N series hardware productdocumentation PDFs, go to the N series support website.

Hardware documentation, including planning, installation and setup, and hardware monitoring,service, and diagnostics, is also provided in an IBM N series Information Center at the following webpage:

publib.boulder.ibm.com/infocenter/nasinfo/nseries/index.jsp

Hardware service and supportYou can receive hardware service through IBM Integrated Technology Services. Visit the followingweb page for support telephone numbers:

www.ibm.com/planetwide/

8 | Gateway Implementation Guide for Third-Party Storage

Page 9: IBM System Storage N series Gateway Implementation Guide

Firmware updatesIBM N series product firmware is embedded in Data ONTAP. As with all devices, ensure that yourun the latest level of firmware. Any firmware updates are posted to the N series support website(accessed and navigated as described in Websites on page 7).

Note: If you do not see new firmware updates on the N series support website, you are running thelatest level of firmware.

Verify that the latest level of firmware is installed on your machine before contacting IBM fortechnical support.

How to send your commentsYour feedback helps us to provide the most accurate and high-quality information. If you havecomments or suggestions for improving this document, please send them by email to [email protected].

Be sure to include the following:

• Exact publication title• Publication form number (for example, GC26-1234-02)• Page, table, or illustration numbers• A detailed description of any information that should be changed

Preface | 9

Page 10: IBM System Storage N series Gateway Implementation Guide

Understanding gateway and third-party storageimplementation

Gateways can be deployed with a variety of third-party storage arrays. Each supported storage arrayhas different configuration requirements and supports only certain configurations.

Array configuration requirements

Each third-party storage array has configuration requirements that must be met in order for the arrayto work with the gateway. These configuration requirements could include the following:

• Identifying the host name of the gateway.• Defining the initiators to which the array is connecting.• Setting failover modes.• Setting host and LUN group information.• Defining the array port configuration.

Supported configurations

Each gateway deployment with a third-party array is limited to the types of configuration that itsupports. When determining the configuration to implement, you need to answer the followingquestions:

• Which configurations are supported for my third-party array?• Will this be a fabric-attached configuration?• Will this be a direct-attached configuration?• How much storage will be available to the gateway?• Will the configuration include a stand-alone gateway, a High Availability (HA) pair, or a

MetroCluster configuration?

Qualification of components in your deployment

The Gateway Interoperability Matrix provides the latest information on hardware models andfirmware versions of switch and storage array products that are currently qualified for use withgateways. Not all Data ONTAP releases support the same features, configurations, storage arraymodels, and gateways.

The following information in the matrix helps you during the system configuration:

• Whether your gateway is supported in the Data ONTAP release that you plan to run.• The maximum and minimum system capacity limits for your gateway.• If you want to deploy a MetroCluster, whether MetroCluster is supported for your storage array.• Whether multiple LUN groups are supported for your storage array.

10 | Gateway Implementation Guide for Third-Party Storage

Page 11: IBM System Storage N series Gateway Implementation Guide

• Which storage array firmware versions are supported.• Whether your storage array supports non-disruptive (live) upgrade of the controller firmware.

Use of advanced features with storage arrays

The gateway does not support third-party array advanced features unless otherwise specified in theGateway Interoperability Matrix.

Detailed information about the planning and installation process

The Gateway Installation Requirements and Reference Guide provides an overview of the gatewaytechnology and a detailed description of planning and requirements, including information about thefollowing:

• Supported methods of connection• Pathing requirements and examples• Array LUN provisioning• LUN security methods• Zoning recommendations• Installation and configuration examples• Installation verification examples

Related information

IBM N series support website: www.ibm.com/storage/support/nseries

Understanding gateway and third-party storage implementation | 11

Page 12: IBM System Storage N series Gateway Implementation Guide

EMC CLARiiON and VNX storage arraysThere are requirements that must be met when configuring storage arrays to work withgateways. These requirements include setting configuration parameters on storage arrays anddeploying only supported configurations.

Requirements for configuring EMC CLARiiON and VNXarrays with gateways

Each EMC CLARiiON and VNX storage array has required configuration parameters that must beset in order to work successfully with gateways.

Required host configuration parametersThere are configuration parameters that must be set in order for the array to communicate with thegateway.

Host configuration parameters that must be set on the storage array are listed in the following table.

Parameter Setting

Initiator type CLARiiON Open

Array Com Path Enabled

Failover mode 1

Unit serial number LUN

Host Name User-supplied host name and port number.

IP address Unique fake IP address. Be sure that you havenot entered this IP address anywhere else in thestorage array configuration, and that it is not anIP address that is present on the network.

General configuration guidelinesInformation in this section includes cautions, restrictions, special requirements, and informationabout array characteristics that you might need to consider when configuring or using the storagearray.

12 | Gateway Implementation Guide for Third-Party Storage

Page 13: IBM System Storage N series Gateway Implementation Guide

How EMC CLARiiON and VNX storage arrays control access to dataEMC CLARiiON and VNX arrays use storage groups to control access to data. A storage group isone or more LUNs within the storage array that can be accessed only by the host or hosts that youassociate with the array LUNs. A host cannot access or modify data in array LUNs that are not partof its storage group.

Gateways support multiple storage groups with the following requirements:

• Switch zoning must define which target ports the gateway initiator ports use to access eacharray LUN group.

• Use LUN masking to restrict host access to array LUNs.• Storage groups must define which array LUN groups are presented to each the gateway initiator

port.• One initiator port pair on each of the gateway system is required for each array LUN group.• All target ports on a storage array accessing an individual array LUN group must be accessed

through the same switch.

When you are using neighborhoods, the gateways in the same neighborhood must be in the samestorage group.

Requirement for 8 Gb array port initializationIn a typical FC fabric, array ports initialize as N-Ports (node ports) and their corresponding switchports initialize as F-Ports (fabric ports). In some cases, N-Ports may go offline and resume operationas L-Ports (loop ports), resulting in fabric errors. This behavior is caused by topology auto-negotiation issues in the Brocade switch.

To ensure that switch ports always initialize as F-ports, run the portcfggport <portnumber> 1command on Brocade switch ports in the configuration. Run this command when you startconfiguring the system to avoid this problem, or to fix the problem if it occurs.

To promote efficiency on the fabric as a whole, use this workaround on any Brocade ports attachedto the gateway initiator ports.

EMC CLARiiON storage array familiesStorage arrays in the same family share the same performance and failover characteristics. Forexample, members of the same family all perform active-active failover, or they all perform active-passive failover. Storage arrays with 4-GB HBAs are not considered to be in the same family asstorage arrays with 8-GB HBAs.

When creating aggregates, you cannot mix array LUNs from arrays that are in different families.

The following list shows CLARiiON storage arrays organized by family:

• Family 1

• CX300• CX500

EMC CLARiiON and VNX storage arrays | 13

Page 14: IBM System Storage N series Gateway Implementation Guide

• CX700• Family 2

• CX3-20• CX3-40• CX3-80

• Family 3

• CX4-120• CX4-240• CX4-480• CX4-960

EMC VNX storage array familiesStorage arrays in the same family share the same performance and failover characteristics. Forexample, members of the same family all perform active-active failover, or they all perform active-passive failover. Storage arrays with 4-GB HBAs are not considered to be in the same family asstorage arrays with 8-GB HBAs.

When creating aggregates, you cannot mix array LUNs from arrays that are in different families.

The supported VNX storage arrays are all members of the same family:

• Family 1

• VNX5100• VNX5300• VNX5500• VNX5700• VNX7500

Supported configurations for EMC CLARiiON and VNXarrays

Only specific configurations of EMC CLARiiON and VNX storage arrays deployed with gatewaysare supported.

Stand-alone basic configurationThe stand-alone basic gateway configuration is a simple fabric-attached configuration with a singleport pair access a single LUN group.

The following illustration shows this configuration.

14 | Gateway Implementation Guide for Third-Party Storage

Page 15: IBM System Storage N series Gateway Implementation Guide

vs1

0a 0b 0c 0d 0e 0f 0g 0h

Storagearray

LUN group

Switch 1 Switch 2

Single 4-port array LUN groupThis configuration contains a single 4-port LUN group with each target port accessed by a singlegateway FC initiator port from the HA pair. Zoning ensures that there are only two paths to a specificarray LUN.

The following illustration shows this configuration.

Storage

0a 0b 0c 0d 0a 0b 0c 0d

LUNs

EMC CLARiiON and VNX storage arrays | 15

Page 16: IBM System Storage N series Gateway Implementation Guide

Stand-alone with two 2-port LUN groupsThis is a stand-alone gateway in a fabric-attached simple configuration. In this configuration, eachFC initiator port pair accesses a separate array LUN group.

The following illustration shows this configuration.

vs1

0a 0b 0c 0d 0e 0f 0g 0h

Storagearray

LUN group

LUN group

16 | Gateway Implementation Guide for Third-Party Storage

Page 17: IBM System Storage N series Gateway Implementation Guide

EMC Symmetrix storage arraysThere are requirements that must be met when configuring storage arrays to work with gateways.These requirements include setting configuration parameters on storage arrays and deploying onlysupported configurations.

Requirements for configuring EMC Symmetrix arrays withgateways

Each EMC Symmetrix storage array has required configuration parameters that must be set in orderto work successfully with gateways.

Required host channel director port configuration parametersThere are configuration parameters that must be set in order for the array to communicate with thegateway.

Host channel director port configuration parameters that must be set on the storage array are listed inthe following table.

Parameter (names may differ between GUIand CLI)

Setting

Common SN (Common Serial Number or C-bitparameter)

Enable

PP (Point-to-Point parameter) Enable

SC3 (SCSI-3) Enable

SPC-2 (SCS2_Protocol_version, SCSI PrimaryCommand 2 parameter, or "Allow inquiry datato be compiled to the standard")

Enable (Contains the second-generationdefinition of the basic commands for all SCSIdevices.)

UWN (Unique Worldwide Name) Enable

Volume Set Addressing Disable

Required host configuration parametersThere are configuration parameters that must be set in order for the array to communicate with thegateway.

Host configuration requirements are provided in the following table:

17

Page 18: IBM System Storage N series Gateway Implementation Guide

Parameter Setting

Host Type Format Server

SCSI3_persist_reserv (Persistent Reservations) On

General configuration guidelinesInformation in this section includes cautions, restrictions, special requirements, and informationabout array characteristics that you might need to consider when configuring or using the storagearray.

Requirements for implementing LUN securityYou use LUN security to eliminate the possibility of a host writing data to a LUN that is not ownedby that host.

To eliminate the possibility of a non gateway overwriting DMX array LUNs owned by a gateway, orthe reverse, you must present the DMX logical devices through the host (channel) director ports ineither of the following ways:

• Present only the DMX logical devices for the gateway on specific DMX host (channel) directorports that are dedicated to gateway use.

• Use LUN masking to associate all DMX logical devices to all host (channel) director ports, butallow only the gateway FC initiator ports to see the LUNs for the gateway.

Attention:

Do not present the VCMDB to all hosts by default. Configure the global setting to restrictvisibility to the VCMDB unless it has been specifically made visible to a particular host.

If you are setting up a configuration in which you are using multiple array LUN groups for thegateway, set up a separate "host group" for each group of LUNs for the gateway.

Caution about using the VCMDB LUNFor the Volume Configuration Management Database (VCMDB) to be enabled, the VCMDB LUNmust exist. The VCMDB LUN is a command type LUN, not a storage LUN. The VCMDB istypically mapped to LUN 0, but can be an array LUN other than LUN 0.

If you map the VCMDB LUN to the gateway, the gateway periodically logs a message that theVCMDB LUN is less than the minimum size required, and it marks the VCMDB LUN as failed. Thegateway continues to function normally after logging this error message.

18 | Gateway Implementation Guide for Third-Party Storage

Page 19: IBM System Storage N series Gateway Implementation Guide

Caution about using the ACLX LUNOn VMAX arrays, the Access Control Logix (ACLX) LUN is automatically created and mapped toLUN0 on each port. The ACLX LUN is not a storage LUN.

When the ACLX LUN is mapped to the gateway, Data ONTAP logs a message that the ACLX LUNis less than the minimum size required, and it marks the LUN as failed. Data ONTAP continues tofunction normally after logging this error message.

Restriction on using a gatekeeper LUNIf a gatekeeper LUN is presented, do not map it to the gateway. Gateways cannot usea gatekeeper LUN. A gatekeeper is a Symmetrix logical device through which SYMAPI or theControlCenter agent communicates with the storage array.

EMC Symmetrix storage array familiesStorage arrays in the same family share the same performance and failover characteristics. Forexample, members of the same family all perform active-active failover, or they all perform active-passive failover. Storage arrays with 4-GB HBAs are not considered to be in the same family asstorage arrays with 8-GB HBAs.

When creating aggregates, you cannot mix array LUNs from arrays that are in different families.

The following list shows the supported arrays organized by families:

• Family1

• VMAX SE• VMAX

• Family 2

• DMX 3• DMX 4

Supported configurations for EMC Symmetrix arraysOnly specific configurations of EMC Symmetrix storage arrays deployed with gateways aresupported.

Stand-alone basic configurationThe stand-alone basic gateway configuration is a simple fabric-attached configuration with a singleport pair access a single LUN group.

The following illustration shows this configuration.

EMC Symmetrix storage arrays | 19

Page 20: IBM System Storage N series Gateway Implementation Guide

vs1

0a 0b 0c 0d 0e 0f 0g 0h

Storagearray

LUN group

Switch 1 Switch 2

Stand-alone with two 2-port LUN groupsThis is a stand-alone gateway in a fabric-attached simple configuration. In this configuration, eachFC initiator port pair accesses a separate array LUN group.

The following illustration shows this configuration.

vs1

0a 0b 0c 0d 0e 0f 0g 0h

Storagearray

LUN group

LUN group

20 | Gateway Implementation Guide for Third-Party Storage

Page 21: IBM System Storage N series Gateway Implementation Guide

Two 4-port array LUN groupsIn this configuration, each the gateway port pair accesses a separate array LUN group. Zoning issingle the gateway FC initiator to single array target port.

The following illustration shows a block diagram of this configuration.

Storage array

vs1

0a 0b 0c 0d

vs2

0a 0b 0c 0d

LUNs

LUNs

EMC Symmetrix storage arrays | 21

Page 22: IBM System Storage N series Gateway Implementation Guide

Fujitsu ETERNUS storage arraysThere are requirements that must be met when configuring storage arrays to work with gateways.These requirements include setting configuration parameters on storage arrays and deploying onlysupported configurations.

Requirements for configuring Fujitsu ETERNUS arrays withgateways

Each Fujitsu ETERNUS storage array has configuration parameters that must be set in order tosuccessfully work with gateways.

Requirement for creating a host response pattern for Fujitsu storage arraysFor the gateway to work with Fujitsu storage arrays, you need to create a new host response patternand set the parameters required by the gateway.

Fujitsu provides host response pattern #00, which is a read-only version of the specification that youedit to match the requirements of your storage array model.

Required host configuration parameters for DX8xxx arraysThere are configuration parameters that must be set in order for the array to communicate with thegateway.

Host configuration parameters that must be set on the storage array are listed in the following table.

Parameter Setting

Host Response Name Name (Gateway name)

Command Time-out Interval Standard (25 seconds)

Data Transfer Timer 10 Seconds (default)

Load Balance Response Unit Attention

Byte-0 Inquiry Response No Conversions (default)

Inquiry VPD ID Type Type1 + Type3 (default)

Inquiry Standard Data Version Version 05 (default)

Reservation Conflict Response for Test UnitReady

Normal Response (default)

Asymmetric / Symmetric Logical Unit Access Active/Active (default)

22 | Gateway Implementation Guide for Third-Party Storage

Page 23: IBM System Storage N series Gateway Implementation Guide

Parameter Setting

Host Specific Mode Normal Mode (default)

LUN Mapping Changes No Report (default)

LUN Capacity Expansion No Report (default)

Vendor Unique Sense Code No report (default)

Sense Code Conversion Pattern No Conversion (default)

Required host configuration parameters for DX4xx arraysThere are configuration parameters that must be set in order for the array to communicate with thegateway.

Host configuration parameters that must be set on the storage array are listed in the following table.

Parameter Setting

Host Response Name Name (Gateway name)

Byte-0 of Inquiry response No Conversion (default)

Inquiry VPD ID Type Type 1 + Type 3

Inquiry Standard Data Version Version 05 (default)

Command Timeout Interval 25 sec (default)

Load Balance Response Unit Attention (default)

Reservation Conflict Response for Test UnitReady

Normal (default)

Change Volume Mapping No Report (default)

Volume Capacity Expansion No Report (default)

Vendor Unique Sense Code No Report (default)

Host Specific Mode Normal (default)

Asymmetric/Symmetric Logical Unit Access Active/Active (default)

Sense Data Conversion No Conversion (default)

Fujitsu ETERNUS storage arrays | 23

Page 24: IBM System Storage N series Gateway Implementation Guide

General configuration guidelinesInformation in this section includes cautions, restrictions, special requirements, and informationabout array characteristics that you might need to consider when configuring or using the storagearray.

Fujitsu ETERNUS storage array familiesStorage arrays in the same family share the same performance and failover characteristics. Forexample, members of the same family all perform active-active failover, or they all perform active-passive failover. Storage arrays with 4-GB HBAs are not considered to be in the same family asstorage arrays with 8-GB HBAs.

All of the supported Fujitsu ETERNUS arrays are in the same family.

Supported configurations for Fujitsu ETERNUS arraysOnly specific configurations of Fujitsu ETERNUS storage arrays deployed with gateways aresupported.

Stand-alone basic configurationThe stand-alone basic gateway configuration is a simple fabric-attached configuration with a singleport pair access a single LUN group.

The following illustration shows this configuration.

vs1

0a 0b 0c 0d 0e 0f 0g 0h

Storagearray

LUN group

Switch 1 Switch 2

24 | Gateway Implementation Guide for Third-Party Storage

Page 25: IBM System Storage N series Gateway Implementation Guide

Single 4-port array LUN groupThis configuration contains a single 4-port LUN group with each target port accessed by a singlegateway FC initiator port from the HA pair. Zoning ensures that there are only two paths to a specificarray LUN.

The following illustration shows this configuration.

Storage

0a 0b 0c 0d 0a 0b 0c 0d

LUNs

Two 2-port array LUN groupsThis configuration consists of a fabric-attached HA pair in which the gateway nodes access arrayLUNs through four ports on the storage array with each LUN group accessed through two ports.

The following illustration shows this configuration.

Fujitsu ETERNUS storage arrays | 25

Page 26: IBM System Storage N series Gateway Implementation Guide

Storage array

vs1

0a 0b 0c 0d

vs2

0a 0b 0c 0d

LUNs

LUNs

Two 4-port array LUN groupsIn this configuration, each the gateway port pair accesses a separate array LUN group. Zoning issingle the gateway FC initiator to single array target port.

The following illustration shows a block diagram of this configuration.

26 | Gateway Implementation Guide for Third-Party Storage

Page 27: IBM System Storage N series Gateway Implementation Guide

Storage array

vs1

0a 0b 0c 0d

vs2

0a 0b 0c 0d

LUNs

LUNs

Fujitsu ETERNUS storage arrays | 27

Page 28: IBM System Storage N series Gateway Implementation Guide

Hitachi Data Systems storage arraysThere are requirements that must be met when configuring Hitachi Data Systems storage arrays towork with gateways. These requirements include setting configuration parameters on storage arraysand deploying only supported configurations.

Requirements for configuring Hitachi Data Systems arrayswith gateways

There are system parameters that you must set and considerations to keep in mind when configuringa storage array to work with a gateway.

Required system parameter for NSC55, USP, and VSP arraysThe host type parameters must be set in order for the array to communicate with the gateway.

The required parameter setting is shown in the following table.

Parameter Setting

Host type Standard or 00

Required system parameters for AMS arraysThere are parameters on the storage array that must be set in order for the array to communicate withthe gateway.

The parameters that must be set in the AMS arrays are listed in the following table.

Parameter Setting

Mapping mode Enabled

Host group security Enabled

Product ID DF600F

Platform Not Specified

Middleware Not Specified

28 | Gateway Implementation Guide for Third-Party Storage

Page 29: IBM System Storage N series Gateway Implementation Guide

General configuration guidelinesInformation in this section includes cautions, restrictions, special requirements, and informationabout array characteristics that you might need to consider when configuring or using the storagearray.

Requirements for creating LUNs in dynamic poolsWhen creating LUNs in the dynamic pools, do not over-provision the pool capacity.

Requirements for formatting array LUNs on Hitachi arraysThere are different types of array LUN formatting that can be performed. Each type has a an impacton the availability of LUNs or the entire storage array.

The following information and recommendations apply when formatting array LUNs:

• Use quick formatting.• Online formatting takes the array LUN that is being formatted completely offline, and the array

LUN does not respond to any SCSI commands.Formatting is performed on one array LUN at a time until all array LUNs are formatted.

• Offline formatting takes the entire storage array offline and the storage array does not respond toany SCSI commands.The array LUNs are formatted six at a time per controller until the formatting is complete.The storage array does not respond until all formatting is complete.

• If you are creating array LUNs (for any host) after initial gateway setup and you are using offlineformatting, the gateway will panic.Any array LUNs that are mapped to the gateway, including array LUNs in the root volume,become unavailable until formatting is complete.

• Online and quick formatting of LUNs for other hosts do not impact the gateway.

Requirements for using disks external to the arrayThe gateway supports the same disks behind the arrays that the vendor supports (that is, disksexternal to the array). The gateway assumes that the configuration between the storage array and theexternal disks behind it is correct.

Restrictions and best practices recommendations for a deployment with storage arrays using externaldisks are provided in the following list:

• Root volumes and spare core LUNs are not supported on external disks.• Do not mix array LUNs from external and internal disks in the same Data ONTAP aggregate.• Do not mix SATA and FC drives in the same aggregate.• There cannot be more than two paths to an array LUN on the external disks from the gateway

through the storage array to the external disks.• Only block checksum is supported on external disks.

Hitachi Data Systems storage arrays | 29

Page 30: IBM System Storage N series Gateway Implementation Guide

Hitachi Data Systems storage array familiesStorage arrays in the same family share the same performance and failover characteristics. Forexample, members of the same family all perform active-active failover, or they all perform active-passive failover. Storage arrays with 4-GB HBAs are not considered to be in the same family asstorage arrays with 8-GB HBAs.

When creating aggregates, you cannot mix array LUNs from arrays that are in different families.

The following list shows the arrays organized by family:

• Family 1

• USP-V• USP-VM

• Family 2

• VSP• Family 3

• AMS 200• AMS 500• AMD 1000

• Family 4

• AMS 2100• AMS 2300• AMS 2500

• Family 5

• USP 1100• USP 600• USP 100• NSC55

Supported configurations for Hitachi Data Systems storagearrays

Only a specific number of configurations of Hitachi Data Systems storage arrays deployed withgateways are supported.

Stand-alone basic configurationThe stand-alone basic gateway configuration is a simple fabric-attached configuration with a singleport pair access a single LUN group.

The following illustration shows this configuration.

30 | Gateway Implementation Guide for Third-Party Storage

Page 31: IBM System Storage N series Gateway Implementation Guide

vs1

0a 0b 0c 0d 0e 0f 0g 0h

Storagearray

LUN group

Switch 1 Switch 2

Stand-alone with two 2-port LUN groupsThis is a stand-alone gateway in a fabric-attached simple configuration. In this configuration, eachFC initiator port pair accesses a separate array LUN group.

The following illustration shows this configuration.

vs1

0a 0b 0c 0d 0e 0f 0g 0h

Storagearray

LUN group

LUN group

Hitachi Data Systems storage arrays | 31

Page 32: IBM System Storage N series Gateway Implementation Guide

Single 4-port array LUN groupThis configuration contains a single 4-port LUN group with each target port accessed by a singlegateway FC initiator port from the HA pair. Zoning ensures that there are only two paths to a specificarray LUN.

The following illustration shows this configuration.

Storage

0a 0b 0c 0d 0a 0b 0c 0d

LUNs

Two-port direct-attached stand-alone configurationDirect-attached configurations are no longer recommended for new deployments. This configurationis shown as a reference for configurations that may already exist in the field.

The following illustration shows a direct-attached configuration for a stand-alone gateway. Two portsprovide access to array LUNs on the storage array.

32 | Gateway Implementation Guide for Third-Party Storage

Page 33: IBM System Storage N series Gateway Implementation Guide

0a 0b 0c 0d 0e 0f 0g 0h

Storagearray

LUN group

Four-port direct-attached HA pair configurationDirect-attached configurations are no longer recommended for new deployments. This configurationis shown as a reference for configurations that may already exist in the field.

The following illustration shows a direct-attached HA pair with four ports providing access to arrayLUNs on the storage array.

Storagearray

vs1 vs2

0a 0b 0c 0d 0a 0b 0c 0d

LUN group

Hitachi Data Systems storage arrays | 33

Page 34: IBM System Storage N series Gateway Implementation Guide

HP EVA storage arraysThere are requirements that must be met when configuring storage arrays to work with gateways.These requirements include setting configuration parameters on storage arrays and deploying onlysupported configurations.

Requirements for configuring HP EVA arrays with gatewaysThere are system parameters that you must set and considerations to keep in mind when configuringa storage array to work with a gateway.

Required system parameters for HP EVA arraysThere are parameters on the storage array that must be set in order for the array to communicate withthe gateway.

System parameter settings are provided in the following table:

Parameter Setting

Redundancy Any raid level except VRAID0

Preferred path/mode No preference (default)

Host type SUN Solaris

General configuration guidelinesInformation in this section includes cautions, restrictions, special requirements, and informationabout array characteristics that you might need to consider when configuring or using the storagearray.

Requirements for configuring multiple LUN groupsThe requirements for configuring multiple LUN groups for an HP EVA storage array are as follows:

• Switch zoning must define which target ports the gateway initiator ports use to access each arrayLUN group.

• Hosts must define which array LUN groups are presented to each gateway initiator port.• Each array LUN group requires one initiator port pair for each gateway.

34 | Gateway Implementation Guide for Third-Party Storage

Page 35: IBM System Storage N series Gateway Implementation Guide

Requirements for configuring the HP EVA Storage Management ServerSharing the gateway initiator ports and HP EVA Storage Management Server initiator ports withcommon EVA target ports causes compatibility issues in gateways.

These issues are seen due to the different host settings for the gateway and the EVA StorageManagement Server initiator ports.

HP recommends that any EVA Storage Management Server that resides in a fabric be configured in aseparate zone from all operating systems.

HP EVA storage array familiesStorage arrays in the same family share the same performance and failover characteristics. Forexample, members of the same family all perform active-active failover, or they all perform active-passive failover. Storage arrays with 4-GB HBAs are not considered to be in the same family asstorage arrays with 8-GB HBAs.

When creating aggregates, you cannot mix array LUNs from arrays that are in different families. Thefollowing list shows arrays organized by family:

• Family 1

• P6300• P6500

• Family 2

• EVA 4100• EVA 6100• EVA 8100

• Family 3

• EVA 4000• EVA 6000• EVA 8000

• Family 4

• EVA 4400• EVA 6400• EVA 8400

Supported configurations for HP EVA arraysOnly a specific number of configurations of HP EVA storage arrays deployed with gateways aresupported.

HP EVA storage arrays | 35

Page 36: IBM System Storage N series Gateway Implementation Guide

Stand-alone with two 2-port LUN groupsThis is a stand-alone gateway in a fabric-attached simple configuration. In this configuration, eachFC initiator port pair accesses a separate array LUN group.

The following illustration shows this configuration.

vs1

0a 0b 0c 0d 0e 0f 0g 0h

Storagearray

LUN group

LUN group

Two 4-port array LUN groupsIn this configuration, each the gateway port pair accesses a separate array LUN group. Zoning issingle the gateway FC initiator to single array target port.

The following illustration shows a block diagram of this configuration.

36 | Gateway Implementation Guide for Third-Party Storage

Page 37: IBM System Storage N series Gateway Implementation Guide

Storage array

vs1

0a 0b 0c 0d

vs2

0a 0b 0c 0d

LUNs

LUNs

HP EVA storage arrays | 37

Page 38: IBM System Storage N series Gateway Implementation Guide

HP XP storage arraysThere are requirements that must be met when configuring storage arrays to work with gateways.These requirements include setting configuration parameters on storage arrays and deploying onlysupported configurations.

Requirements for configuring HP XP arrays with gatewaysEach HP XP storage array has configuration parameters that must be set in order to successfullywork with gateways.

Required system parameter for all HP XP modelsThe host type parameters must be set in order for the array to communicate with the gateway.

The required parameter setting is shown in the following table.

Parameter Setting

Host type Standard or 00

General configuration guidelinesInformation in this section includes cautions, restrictions, special requirements, and informationabout array characteristics that you might need to consider when configuring or using the storagearray.

Requirements for using disks external to the arrayThe gateway supports the same disks behind the arrays that the vendor supports (that is, disksexternal to the array). The gateway assumes that the configuration between the storage array and theexternal disks behind it is correct.

Restrictions and best practices recommendations for a deployment with storage arrays using externaldisks are provided in the following list:

• Root volumes and spare core LUNs are not supported on external disks.• Do not mix array LUNs from external and internal disks in the same Data ONTAP aggregate.• Do not mix SATA and FC drives in the same aggregate.• There cannot be more than two paths to an array LUN on the external disks from the gateway

through the storage array to the external disks.• Only block checksum is supported on external disks.

38 | Gateway Implementation Guide for Third-Party Storage

Page 39: IBM System Storage N series Gateway Implementation Guide

Requirements for configuring portsThere are requirements that must be met when configuring ports on HP XP arrays.

The following list describes the requirements for configuring ports.

• Only one host group per port is supported.• A host group must include all ports of the gateways in a gateway neighborhood.

HP XP storage array familiesStorage arrays in the same family share the same performance and failover characteristics. Forexample, members of the same family all perform active-active failover, or they all perform active-passive failover. Storage arrays with 4-GB HBAs are not considered to be in the same family asstorage arrays with 8-GB HBAs.

When creating aggregates, you cannot mix array LUNs from arrays that are in different families. Thefollowing list shows arrays organized by family:

• Family 1

• P9500• Family 2

• XP24000• XP20000• XP12000• XP10000

Supported configurations for HP XP arraysOnly a specific number of configurations of HP XP storage arrays deployed with gateways aresupported.

Stand-alone basic configurationThe stand-alone basic gateway configuration is a simple fabric-attached configuration with a singleport pair access a single LUN group.

The following illustration shows this configuration.

HP XP storage arrays | 39

Page 40: IBM System Storage N series Gateway Implementation Guide

vs1

0a 0b 0c 0d 0e 0f 0g 0h

Storagearray

LUN group

Switch 1 Switch 2

Stand-alone with two 2-port LUN groupsThis is a stand-alone gateway in a fabric-attached simple configuration. In this configuration, eachFC initiator port pair accesses a separate array LUN group.

The following illustration shows this configuration.

vs1

0a 0b 0c 0d 0e 0f 0g 0h

Storagearray

LUN group

LUN group

40 | Gateway Implementation Guide for Third-Party Storage

Page 41: IBM System Storage N series Gateway Implementation Guide

Two-port direct-attached stand-alone configurationDirect-attached configurations are no longer recommended for new deployments. This configurationis shown as a reference for configurations that may already exist in the field.

The following illustration shows a direct-attached configuration for a stand-alone gateway. Two portsprovide access to array LUNs on the storage array.

0a 0b 0c 0d 0e 0f 0g 0h

Storagearray

LUN group

Four-port direct-attached HA pair configurationDirect-attached configurations are no longer recommended for new deployments. This configurationis shown as a reference for configurations that may already exist in the field.

The following illustration shows a direct-attached HA pair with four ports providing access to arrayLUNs on the storage array.

HP XP storage arrays | 41

Page 42: IBM System Storage N series Gateway Implementation Guide

Storagearray

vs1 vs2

0a 0b 0c 0d 0a 0b 0c 0d

LUN group

42 | Gateway Implementation Guide for Third-Party Storage

Page 43: IBM System Storage N series Gateway Implementation Guide

IBM DS storage arraysThere are requirements that must be met when configuring storage arrays to work with gateways.These requirements include setting configuration parameters on storage arrays and deploying onlysupported configurations.

Requirements for configuring IBM DS arrays with thegateway

There are system parameters that you must set and considerations to keep in mind when configuringa storage array to work with a gateway.

Required host type for DS8xxx arraysThe host type parameter must be set in order for the array to communicate with the gateway.

The required host type setting is shown in the following table.

Parameter Setting

Host type nseries

Required host type for DS3950 DS4xxx and DS5xxx arraysThe host type parameter must be set in order for the array to communicate with the gateway.

The required host type setting is shown in the following table.

Parameter Setting

Host type AIX

Requirements for configuring DS8300 9A2 LPAR modelsWhen setting up the DS8300 9A2 LPAR (system logical partition) model to interact with gateways,ensure that you set up access to each array LUN so that the redundant paths are both accessing thesame LPAR.

General configuration guidelinesInformation in this section includes cautions, restrictions, special requirements, and informationabout array characteristics that you might need to consider when configuring or using the storagearray.

43

Page 44: IBM System Storage N series Gateway Implementation Guide

Requirements for volume groups on DS8xxx storage arraysThere are limitations on the number of volume groups you can use with a LUN group whenconfiguring DS8xxx arrays.

Use a single volume group for each LUN group on a DS8xxx storage array to guarantee the DS8xxxarray LUNs are consistently presented to all gateway initiators that access them.

Attention: If array LUNs are not consistently presented there is a potential for data corruption.

Requirements for multiple LUN groups on all IBM DS arraysThere are requirements that must be met when configuring multiple LUN groups on IBM DS arrays.

These requirements are provided in the following list.

• Switch zoning must define which target ports the gateway FC initiator ports use to access eachLUN group.

• Volume groups must define which LUN groups are presented to each gateway initiator port.• One initiator port pair for each gateway is required for each LUN group.

Requirements for direct-attached configurations with all IBM DS arraysThere are requirements that must be met in order for gateway to communicate with IBM DS arrays ina direct-attached configuration.

The following list describes the requirements that must be met when configuring direct-attached IBMDS arrays.

• Create Host Attachment files for the array ports.• Set the Host Attachment Port type to FcAL (Fibre Channel Arbitrated Loop).• Set the Storage Image I/O port to FcAL.

Note: Direct-attached configurations are no longer recommended for new deployments. Thisinformation is provided as a reference for configurations that may already exist in the field.

IBM DS storage array familiesStorage arrays in the same family share the same performance and failover characteristics. Forexample, members of the same family all perform active-active failover, or they all perform active-passive failover. Storage arrays with 4-GB HBAs are not considered to be in the same family asstorage arrays with 8-GB HBAs.

When creating aggregates, you cannot mix array LUNs from arrays that are in different families.

The following list shows arrays organized by family:

• Family 1

• DS4800• DS4700

44 | Gateway Implementation Guide for Third-Party Storage

Page 45: IBM System Storage N series Gateway Implementation Guide

• DS4200• Family 2

• DS5100• DS5300

• Family 3

• DS8300• DS8100

• Family 4

• DS5020• DS3950

• Family 5

• DS8800 model 951

• Family 6

• DS8700 models 941, 94E

Supported configurations for IBM DS arraysOnly a specific number of configurations of IBM storage arrays deployed with gateways aresupported.

Stand-alone basic configurationThe stand-alone basic gateway configuration is a simple fabric-attached configuration with a singleport pair access a single LUN group.

The following illustration shows this configuration.

IBM DS storage arrays | 45

Page 46: IBM System Storage N series Gateway Implementation Guide

vs1

0a 0b 0c 0d 0e 0f 0g 0h

Storagearray

LUN group

Switch 1 Switch 2

Two 2-port array LUN groupsThis configuration consists of a fabric-attached HA pair in which the gateway nodes access arrayLUNs through four ports on the storage array with each LUN group accessed through two ports.

The following illustration shows this configuration.

46 | Gateway Implementation Guide for Third-Party Storage

Page 47: IBM System Storage N series Gateway Implementation Guide

Storage array

vs1

0a 0b 0c 0d

vs2

0a 0b 0c 0d

LUNs

LUNs

Single 4-port array LUN groupThis configuration contains a single 4-port LUN group with each target port accessed by a singlegateway FC initiator port from the HA pair. Zoning ensures that there are only two paths to a specificarray LUN.

The following illustration shows this configuration.

IBM DS storage arrays | 47

Page 48: IBM System Storage N series Gateway Implementation Guide

Storage

0a 0b 0c 0d 0a 0b 0c 0d

LUNs

Two 4-port array LUN groupsIn this configuration, each the gateway port pair accesses a separate array LUN group. Zoning issingle the gateway FC initiator to single array target port.

The following illustration shows a block diagram of this configuration.

48 | Gateway Implementation Guide for Third-Party Storage

Page 49: IBM System Storage N series Gateway Implementation Guide

Storage array

vs1

0a 0b 0c 0d

vs2

0a 0b 0c 0d

LUNs

LUNs

Two-port direct-attached stand-alone configurationDirect-attached configurations are no longer recommended for new deployments. This configurationis shown as a reference for configurations that may already exist in the field.

The following illustration shows a direct-attached configuration for a stand-alone gateway. Two portsprovide access to array LUNs on the storage array.

IBM DS storage arrays | 49

Page 50: IBM System Storage N series Gateway Implementation Guide

0a 0b 0c 0d 0e 0f 0g 0h

Storagearray

LUN group

Four-port direct-attached HA pair configurationDirect-attached configurations are no longer recommended for new deployments. This configurationis shown as a reference for configurations that may already exist in the field.

The following illustration shows a direct-attached HA pair with four ports providing access to arrayLUNs on the storage array.

Storagearray

vs1 vs2

0a 0b 0c 0d 0a 0b 0c 0d

LUN group

50 | Gateway Implementation Guide for Third-Party Storage

Page 51: IBM System Storage N series Gateway Implementation Guide

IBM XIV storage arraysThere are requirements that must be met when configuring storage arrays to work with gateways.These requirements include setting configuration parameters on storage arrays and deploying onlysupported configurations.

Requirements for configuring IBM XIV arrays with gatewaysThere are system parameters that you must set and considerations to keep in mind when configuringan XIV storage array to work with a gateway.

Required system parameters for IBM XIV arraysThere are parameters on the storage array that must be set in order for the array to communicate withthe gateway.

System parameter settings for IBM XIV Gen2 and Gen3 arrays are provided in the following table.

Parameter Setting

Type Default

Host User-supplied host name

Cluster User-supplied cluster name

Supported configurations for IBM XIV arraysOnly a specific number of configurations of IBM XIV storage arrays deployed with gateways issupported.

Single 4-port array LUN groupThis configuration contains a single 4-port LUN group with each target port accessed by a singlegateway FC initiator port from the HA pair. Zoning ensures that there are only two paths to a specificarray LUN.

The following illustration shows this configuration.

51

Page 52: IBM System Storage N series Gateway Implementation Guide

Storage

0a 0b 0c 0d 0a 0b 0c 0d

LUNs

52 | Gateway Implementation Guide for Third-Party Storage

Page 53: IBM System Storage N series Gateway Implementation Guide

3PAR storage arraysThere are requirements that must be met when configuring storage arrays to work with gateways.These requirements include setting configuration parameters on storage arrays and deploying onlysupported configurations.

Requirements for configuring 3PAR arrays with gatewaysThere are system parameters that you must set and considerations to keep in mind when configuringa storage array to work with a gateway.

Required system parameters for 3PAR arraysThere are parameters on the storage array that must be set in order for the array to communicate withthe gateway.

For 3PAR arrays with firmware version 2.3.1 and later, the required host persona values must be setas shown in the following table.

Connection type Host persona

Direct Connect 10

Fabric attached 10

For 3PAR arrays with firmware version 2.2.x, the required port persona values must be set as shownin the following table.

Connection type Port persona

Direct Connect 18

Fabric attached 19

General configuration guidelinesInformation in this section includes cautions, restrictions, special requirements, and informationabout array characteristics that you might need to consider when configuring or using the storagearray.

3PAR storage array familiesStorage arrays in the same family share the same performance and failover characteristics. Forexample, members of the same family all perform active-active failover, or they all perform active-

53

Page 54: IBM System Storage N series Gateway Implementation Guide

passive failover. Storage arrays with 4-GB HBAs are not considered to be in the same family asstorage arrays with 8-GB HBAs.

When creating aggregates, you cannot mix array LUNs from arrays that are in different families.

The following list shows arrays organized by family:

• Family 1

• E200

• Family 2

• S400• S800

• Family 3

• T400• T800

• Family 4

• F200• F400

• Family 5

• P10000 - V400• P10000 - V800

Supported configurations for 3PAR arraysOnly a specific number of configurations of 3PAR storage arrays deployed with gateways aresupported.

Single 4-port array LUN groupThis configuration contains a single 4-port LUN group with each target port accessed by a singlegateway FC initiator port from the HA pair. Zoning ensures that there are only two paths to a specificarray LUN.

The following illustration shows this configuration.

54 | Gateway Implementation Guide for Third-Party Storage

Page 55: IBM System Storage N series Gateway Implementation Guide

Storage

0a 0b 0c 0d 0a 0b 0c 0d

LUNs

Two-port direct-attached stand-alone configurationDirect-attached configurations are no longer recommended for new deployments. This configurationis shown as a reference for configurations that may already exist in the field.

The following illustration shows a direct-attached configuration for a stand-alone gateway. Two portsprovide access to array LUNs on the storage array.

0a 0b 0c 0d 0e 0f 0g 0h

Storagearray

LUN group

3PAR storage arrays | 55

Page 56: IBM System Storage N series Gateway Implementation Guide

Copyright and trademark information

Copyright ©1994 - 2012 NetApp, Inc. All rights reserved. Printed in the U.S.A.

Portions copyright © 2012 IBM Corporation. All rights reserved.

US Government Users Restricted Rights - Use, duplication or disclosurerestricted by GSA ADP Schedule Contract with IBM Corp.

No part of this document covered by copyright may be reproduced in anyform or by any means— graphic, electronic, or mechanical, includingphotocopying, recording, taping, or storage in an electronic retrievalsystem—without prior written permission of the copyright owner.

References in this documentation to IBM products, programs, or services donot imply that IBM intends to make these available in all countries in whichIBM operates. Any reference to an IBM product, program, or service is notintended to state or imply that only IBM’s product, program, or service maybe used. Any functionally equivalent product, program, or service that doesnot infringe any of IBM’s or NetApp’s intellectual property rights may beused instead of the IBM or NetApp product, program, or service. Evaluationand verification of operation in conjunction with other products, except thoseexpressly designated by IBM and NetApp, are the user’s responsibility.

No part of this document covered by copyright may be reproduced in anyform or by any means— graphic, electronic, or mechanical, includingphotocopying, recording, taping, or storage in an electronic retrievalsystem—without prior written permission of the copyright owner.

Software derived from copyrighted NetApp material is subject to thefollowing license and disclaimer:

THIS SOFTWARE IS PROVIDED BY NETAPP "AS IS" AND WITHOUT ANYEXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITEDTO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESSFOR A PARTICULAR PURPOSE, WHICH ARE HEREBY DISCLAIMED. INNO EVENT SHALL NETAPP BE LIABLE FOR ANY DIRECT, INDIRECT,INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES(INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTEGOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESSINTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OFLIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT

© Copyright IBM Corp. 2012 56

Page 57: IBM System Storage N series Gateway Implementation Guide

(INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUTOF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THEPOSSIBILITY OF SUCH DAMAGE.

NetApp reserves the right to change any products described herein at anytime, and without notice. NetApp assumes no responsibility or liability arisingfrom the use of products described herein, except as expressly agreed to inwriting by NetApp. The use or purchase of this product does not convey alicense under any patent rights, trademark rights, or any other intellectualproperty rights of NetApp.

The product described in this manual may be protected by one or more U.S.A.patents, foreign patents, or pending applications.

RESTRICTED RIGHTS LEGEND: Use, duplication, or disclosure by thegovernment is subject to restrictions as set forth in subparagraph (c)(1)(ii) ofthe Rights in Technical Data and Computer Software clause at DFARS252.277-7103 (October 1988) and FAR 52-227-19 (June 1987).

Trademark information

IBM, the IBM logo, and ibm.com are trademarks or registered trademarks ofInternational Business Machines Corporation in the United States, othercountries, or both. A complete and current list of other IBM trademarks isavailable on the Web at http://www.ibm.com/legal/copytrade.shtml

Linux is a registered trademark of Linus Torvalds in the United States, othercountries, or both.

Microsoft, Windows, Windows NT, and the Windows logo are trademarks ofMicrosoft Corporation in the United States, other countries, or both.

UNIX is a registered trademark of The Open Group in the United States andother countries.

NetApp, the NetApp logo, Network Appliance, the Network Appliance logo,Akorri, ApplianceWatch, ASUP, AutoSupport, BalancePoint, BalancePointPredictor, Bycast, Campaign Express, ComplianceClock, Cryptainer,CryptoShred, Data ONTAP, DataFabric, DataFort, Decru, Decru DataFort,DenseStak, Engenio, Engenio logo, E-Stack, FAServer, FastStak, FilerView,FlexCache, FlexClone, FlexPod, FlexScale, FlexShare, FlexSuite, FlexVol,FPolicy, GetSuccessful, gFiler, Go further, faster, Imagine Virtually Anything,Lifetime Key Management, LockVault, Manage ONTAP, MetroCluster,MultiStore, NearStore, NetCache, NOW (NetApp on the Web), Onaro,OnCommand, ONTAPI, OpenKey, PerformanceStak, RAID-DP, ReplicatorX,SANscreen, SANshare, SANtricity, SecureAdmin, SecureShare, Select, Service

57 IBM System Storage N series: Gateway Implementation Guide For Third-Party Storage

Page 58: IBM System Storage N series Gateway Implementation Guide

Builder, Shadow Tape, Simplicity, Simulate ONTAP, SnapCopy, SnapDirector,SnapDrive, SnapFilter, SnapLock, SnapManager, SnapMigrator, SnapMirror,SnapMover, SnapProtect, SnapRestore, Snapshot, SnapSuite, SnapValidator,SnapVault, StorageGRID, StoreVault, the StoreVault logo, SyncMirror, TechOnTap, The evolution of storage, Topio, vFiler, VFM, Virtual File Manager,VPolicy, WAFL, Web Filer, and XBB are trademarks or registered trademarksof NetApp, Inc. in the United States, other countries, or both.

All other brands or products are trademarks or registered trademarks of theirrespective holders and should be treated as such.

NetApp, Inc. is a licensee of the CompactFlash and CF Logo trademarks.

NetApp, Inc. NetCache is certified RealSystem compatible.

Notices

This information was developed for products and services offered in theU.S.A.

IBM may not offer the products, services, or features discussed in thisdocument in other countries. Consult your local IBM representative forinformation on the products and services currently available in your area. Anyreference to an IBM product, program, or service is not intended to state orimply that only that IBM product, program, or service may be used. Anyfunctionally equivalent product, program, or service that does not infringe onany IBM intellectual property right may be used instead. However, it is theuser’s responsibility to evaluate and verify the operation of any non-IBMproduct, program, or service.

IBM may have patents or pending patent applications covering subject matterdescribed in this document. The furnishing of this document does not giveyou any license to these patents. You can send license inquiries, in writing to:

IBM Director of LicensingIBM CorporationNorth Castle DriveArmonk, N.Y. 10504-1785U.S.A.

For additional information, visit the web at:http://www.ibm.com/ibm/licensing/contact/

The following paragraph does not apply to the United Kingdom or any othercountry where such provisions are inconsistent with local law:

Copyright and trademark information 58

Page 59: IBM System Storage N series Gateway Implementation Guide

INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDESTHIS PUBLICATION “AS IS” WITHOUT WARRANTY OF ANY KIND,EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO,THE IMPLIED WARRANTIES OF NON-INFRINGEMENT,MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Somestates do not allow disclaimer of express or implied warranties in certaintransactions, therefore, this statement may not apply to you.

This information could include technical inaccuracies or typographical errors.Changes are periodically made to the information herein; these changes willbe incorporated in new editions of the publication. IBM may makeimprovements and/or changes in the product(s) and/or the program(s)described in this publication at any time without notice.

Any references in this information to non-IBM web sites are provided forconvenience only and do not in any manner serve as an endorsement of thoseweb sites. The materials at those web sites are not part of the materials forthis IBM product and use of those web sites is at your own risk.

IBM may use or distribute any of the information you supply in any way itbelieves appropriate without incurring any obligation to you.

Any performance data contained herein was determined in a controlledenvironment. Therefore, the results obtained in other operating environmentsmay vary significantly. Some measurements may have been made ondevelopment-level systems and there is no guarantee that these measurementswill be the same on generally available systems. Furthermore, somemeasurement may have been estimated through extrapolation. Actual resultsmay vary. Users of this document should verify the applicable data for theirspecific environment.

Information concerning non-IBM products was obtained from the suppliers ofthose products, their published announcements or other publicly availablesources. IBM has not tested those products and cannot confirm the accuracyof performance, compatibility or any other claims related to non-IBMproducts. Questions on the capabilities of non-IBM products should beaddressed to the suppliers of those products.

If you are viewing this information in softcopy, the photographs and colorillustrations may not appear.

59 IBM System Storage N series: Gateway Implementation Guide For Third-Party Storage

Page 60: IBM System Storage N series Gateway Implementation Guide

Index3PAR

array families 53configuration requirements 53required system parameters 53supported configurations 54

AACLX LUN 19AMS

required parameters 28array families

3PAR 53EMC CLARiiON 13EMC Symmetrix 19EMC VNX 14Fujitsu ETERNUS 24Hitachi 30HP XP 39IBM DS 44

array family informationHP EVA 35

array LUNsformatting 29

array port initialization 13

Cconfiguration requirements

3PAR 53DS8300 9A2 LPAR 43EMC CLARiiON 12EMC Symmetrix 17EMC VNX 12Fujitsu ETERNUS 22Hitachi 28HP XP 38IBM DS 43IBM XIV 51

Ddirect attached configurations

requirements for IBM DS arrays 44DS3950

host type setting 43DS4xxx

host type setting 43DS5xxx

host type setting 43DS8xxx

volume groups 44DX4xx arrays

host parameters 23DX8xxx

host parameters 22

EEMC CLARiiON

array families 13configuration requirements 12storage groups 13supported configurations 14

EMC Symmetrixconfiguration requirements 17gatekeeper LUN 19supported configurations 19

EMC VNXarray families 14configuration requirements 12storage groups 13supported configurations 14

FFujitsu ETERNUS

array families 24configuration requirements 22Host Response Profile 22supported configurations 24

Ggatekeeper LUN 19

HHitachi

configuration requirements 28

Index | 60

Page 61: IBM System Storage N series Gateway Implementation Guide

supported configurations 30using external disks 28

host persona 53Host Response Profile 22host type

NSC55 28HP EVA

array family information 35configuration requirements

HP EVA 34host limits 34requirements for multiple LUN groups 34Storage Management Server 34supported configurations 35

HP XParray families 39configuration requirements 38port configuration 39using external disks 38

IIBM DS

array families 44configuration requirements 43supported configurations 45

IBM DS arraysmultiple LUN groups 44

IBM XIVconfiguration requirements 51required system parameters 51supported configurations 51

LLUN security

EMC SymmertixLUN security 18

Pport persona 53portcfggport command 13

Ssupported configurations

3PAR 54EMC CLARiiON 14EMC Symmetrix 19EMC VNX 14Fujitsu ENTERNUS 24Hitachi 30HP EVA 35IBM DS 45IBM XIV 51

VVCMDB

restricting visibility 18VCMDB LUN 18volume groups

DS8xxx 44

61 | Gateway Implementation Guide for Third-Party Storage

Page 62: IBM System Storage N series Gateway Implementation Guide
Page 63: IBM System Storage N series Gateway Implementation Guide

����

NA 210-05713_A0, Printed in USA

GA32-1050-02