IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation 3 IBM System Storage N6000 plus Gateways Expanding the fastest growing IBM disk storage family N3300 N3600 N5300 N TB 336TB 504TB 104TB 68TB N7900 N TB 1,176TB N TB N TB N5600  New N6000 products are direct replacements for N5300/N5600  Single architecture for NAS, FC-SAN, and iSCSI storage  Data ONTAP® provides a single application interface  One set of management tools

TRANSCRIPT

Page 1: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM Corporation

IBM System Storage – N series

This document is for IBM and IBM Business Partner use only. It is not intended for customer distribution or use with customers.

Page 2: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM CorporationIBM System Storage N series Business Solutions

Agenda – Solutions with Software

1. Data ONTAP2. iSCSI3. iSCSI Host Utility for UNIX,

Windows & Linux4. FTP5. Snapshot6. SnapMover (co-req MultiStore)7. SyncMirror8. FilerView9. FlexVol10. FlexShare11. SecureAdmin12. AutoSupport13. Disk Sanitization14. RAID-DP*15. RAID-4*

16. CIFS Protocol17. NFS Protocol18. HTTP Protocol19. FCP Protocol20. Cluster Failover21. FlexClone22. MultiStore23. SnapMirror24. SnapRestore25. SnapVault26. Open Systems SnapVault27. SnapLock Enterprise28. LockVault Enterprise29. SnapLock Compliance*30. LockVault Compliance*31. SnapDrive for Windows32. SnapDrive for Unix & Linux33. NearStore feature34. MetroCluster

No-Charge Features

35. SnapManager for SQL36. SnapManager for Exchange 37. Single Mailbox Recovery for Exchange38. SnapManager for Oracle39. SnapValidator40. FCP Host Utility for UNIX, Win & Linux41. Operations Manager Core42. Operations Manager SRM43. Protection Manager44. Advanced Single Instance Storage*45. Virtual File Manager (VFM)

Optional Features

Business Solutions

Recovery

Retention

Operation

Simplification

* Not available on Gateways

Page 3: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM Corporation3

IBM System Storage N6000 plus GatewaysExpanding the fastest growing IBM disk storage family

N3300

N3600

N5300N5200

168TB336TB

504TB104TB

68TB

N7900

N7700

840TB

1,176TB

N6040N6040420TB420TB

N6070N6070840TB840TB

N5600

New N6000 products are direct replacements

for N5300/N5600

Single architecture for NAS,

FC-SAN, and iSCSI storage

Data ONTAP® provides a

single application interface

One set of management tools

Page 4: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM CorporationIBM System Storage N series Business Solutions

Simplification

Page 5: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM CorporationIBM System Storage N series Business Solutions

Simplification

Multi-Protocol – FCP, iSCSI, CIFS, NFS, HTTP, FTP

Multi-Function – SAN, NAS, Backup, Compliance

Scalability – Workgroup to Enterprise

Availability – RAID to MetroCluster

Virtualization – MultiStore, FlexVol, FlexClone, SnapMover

Page 6: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM CorporationIBM System Storage N series Business Solutions

SimplificationMulti-Protocol

Traditional Arrays Only Offer

Fibre Channel

• NAS

• IP SAN

• FC SAN

Page 7: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM Corporation7

N series GatewaysLeverage existing Storage Assets while introducing advanced N series Software functionalityN3700

16TB

N5600504TB

N520084TB

N7700840TB

N79001.2PB

N5300336TB

N330024TB

N360069TB

Simplification

Single Operating System - ONTAP

Page 8: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM CorporationIBM System Storage N series Business Solutions

SimplificationP DP

• Designed to survive all 2-disk failure scenarios

• Essential for SATA drives but also applicable to FC drives

• Protects better than single-parity RAID or RAID0+1

• No performance penalty for industry-leading protection

• As disk drives get bigger traditional single-parity RAID technology offers protection from a single failed disk drive.

• With modern larger disk media, the likelihood of an uncorrectable bit error is fairly high, since disk capacities have increased but bit error rates have stayed the same.

RAID-DP™

• The expectation is that no other disk fails nor uncorrectable bit errors not occur during a read operation while reconstruction of the failed disk is still in progress.

• If either event occurs during reconstruction, then some or all data contained in the RAID array or volume could be lost.

• The ability of traditional single-parity RAID to protect data is being stretched beyond its limits.

Page 9: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM CorporationIBM System Storage N series Business Solutions

SimplificationMultiStore

WinFileServer1

WinFileServer2

WinFileServer3

UnixFileServer1

UnixFileServer2

WinFileServer1

VM

WinFileServer2

VM

WinFileServer3

VM

UnixFileServer1

VM

UnixFileServer2

VM

• Create virtual machines (VM) of existing Servers

• Collapse Existing Environment• No Client Re-Configuration• Same Management Structure

H:\\WinFileServer3\User

Partitioning

Page 10: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM CorporationIBM System Storage N series Business Solutions

Simplification

FlexVol

• Designed to allow administrators to create multiple flexible volumes across a large pool of disks

• Dynamic, non-disruptive storage (thin) provisioning; space- and time-efficiency

• Allows users to get more space dynamically and non-disruptively

• Can enable more productive use of available storage and helps improve performance by distributing applications across more spindles

• Grow and Shrink NAS file systems on the fly.

FlexVol™Without FlexVol,

application is limited to pre-assigned space Application is free to

grab more space if needed

• Increase storage utilization• Enable thin provisioning and re-allocation• Increase application performance

Page 11: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM CorporationIBM System Storage N series Business Solutions

SimplificationFlexClone

Writeable copies consume space and time Impacts deployment time

FlexClone copies are near-instantaneous Storage efficient Significant Cost Savings

Production – 1TB

Test – 1TB

Test2 – 1TB

Dev – 1TB

QA – 1TB

Total = 5TB’s

Traditional Arrays

Production – 1TB

Test – 40KB

Test2 – 40KB

Dev – 40KB

QA – 40KB

Total = 1TB + Changes

N series FlexClones

Writeable Snapshots

Page 12: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM CorporationIBM System Storage N series Business Solutions

Simplification

SnapMover

• Local data migration solution for optimizing workloads across N series sharing a common disk array.

• Designed to allow you to migrate ownership of a volume from one N series Controller to its Partner Controller with a single command.

• Designed to allow better resource utilization and performance amongst multiple N series devices

DB1

DB2

DB3

DB4

Clustered N series Controllers

DB1 is Highly Utilized

SnapMover Migrates DB2 Workload On the Fly to

Alternate N series Controller

Note: MultiStore and Clustering are prerequisites

Static Load Balancing

Page 13: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM CorporationIBM System Storage N series Business Solutions

Simplification

Availability

Cost

Block Level Incremental (BLI) Backups

Asynchronous Replication

LAN/WANClustering

ContinuousOperationsSynchronous

Replication

ApplicationRecovery

DailyBackup

Snapshot™Copies

SynchronousClusters

MetroCluster

SynchronousSnapMirror® and Clusters

SnapVault™

SnapRestore®

RAID-DP™

FlexClones®

Data Integrity

App Testing

Availability

Options

Synchronous SnapMirror and SyncMirror™

Asynchronous SnapMirror

Low-Level SLA Medium-Level SLA High-Level SLA

Page 14: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM CorporationIBM System Storage N series Business Solutions

Recovery

Page 15: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM CorporationIBM System Storage N series Business Solutions

Recovery

Snapshot – Instantaneous Backup (RPO)

SnapRestore – System Recovery in Seconds (RTO)

SnapMirror – System Replication (RPO/RTO)

SnapManager – Application Integration (RPO/RTO)

MetroCluster – Failover from primary to secondary site

Page 16: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM CorporationIBM System Storage N series Business Solutions

Recovery

Snapshot

• Instantaneous Backup of NAS and SAN data

• Restores of either large files or entire flexible volume

• 255 Snapshots per FlexVol (499 FlexVol’s per N series)

• Drag and drop restore of user files – significant reduction in RTO and RPO

• No performance impact in keeping multiple online SnapShots

• Automated Application Integration into MS Exchange, MS SQL and Oracle

• SPACE EFFICIENT because only block level updates occur

Production Data

Snapshot Backups

1. Data Corruption/Deletion

2. Copy document from Snapshot folder to production folder

3. Reduce recovery to minutes instead of hours or days

Hourly0

Hourly1

Hourly2

Page 17: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM CorporationIBM System Storage N series Business Solutions

Recovery

SnapRestore

• Near instantaneous restoration of NAS and SAN data

• Restores of either large files or entire flexible volume

• Significant reduction in recovery time

• Automated application integration into MS Exchange, MS SQL and Oracle

Production Data

Database or Application Snapshot Backups

Hourly0Hourly1

Hourly2

1. Data Corruption/Deletion

2. Issue SnapRestore to most recent hourly snapshot and replay transaction logs

3. Reduce recover time to minutes instead of hours or days

Page 18: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM CorporationIBM System Storage N series Business Solutions

Recovery

SnapMirror

• Replication via IP or Fibre channel (FC via RPQ)

• Asynchronous, Semi-synchronous and synchronous

• One to one, one to many, many to one and cascading, multi-site

• Supported across entire N series product line

• Mirroring to NetApp equipment also supported

Remote Office A

Remote Office B

Central Data

Center

SnapMirror

NDMP Serverless

Backup to Tape

N series

N seriesN series

Page 19: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM CorporationIBM System Storage N series Business Solutions

Recovery

SnapManager

• Automated application Integration and availability for Microsoft Exchange, Microsoft SQL, SAP and Oracle

• SnapShot• SnapRestore • SnapMirror – Application disaster

recovery• SnapDrive – Grow application storage

on the fly• Automated DB and message store

Migration• Optional for MS Exchange:

• Single Mailbox Recovery

Application Servers

Central Data

Center

Hourly Snapshotsfor Local Recovery

SnapMirror for Remote

Recovery with Snapshots

Failover to D/R Site

Site or System Disaster

Reduces implementation time, increase availability and reduce RPO and RTO

Disaster Recovery

Site

Page 20: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM CorporationIBM System Storage N series Business Solutions

Recovery

MetroCluster

Fabric

X Ym YXm

Vol-X Mirrored Vol-Y Mirrored Vol-X Vol-Y

Site A Site BStretch

• Extends clustered failover capabilities from primary to a remote site

• Replicates data from the primary site to the remote site to ensure the data there is completely up-to-date and available

• If Site A goes down, MetroCluster allows you to rapidly resume operations at a remote site minutes after a disaster

• Stretch MetroCluster provides a disaster recovery option at distances to 500 meters between each N series node. Available on N5000 & N7000 models (Axx)

• Fabric MetroCluster provides a disaster recovery option at distances up to 100km using a fibre channel switched network. Available on N5000 Models (Axx)

Page 21: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM CorporationIBM System Storage N series Business Solutions

Retention

Page 22: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM CorporationIBM System Storage N series Business Solutions

Retention

SATA and FC Disk – Mix and Match

SnapLock – Non-erasable, non-rewriteable (WORM) data protection for archival and

compliance

SnapVault & Open Systems SnapVault – Block Backups

NearStore Feature – Maintains a fixed upper limit for concurrent

SnapMirror and SnapVault transfers

Page 23: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM CorporationIBM System Storage N series Business Solutions

Retention

SATA and FC Disk

• N series Support both Fibre Channel (F/C) and Serial ATA disks (SATA) concurrently

• Reduce costs by deploying non transaction oriented applications (File services, archive, compliance) on lower cost SATA disks

• Use faster, more expensive Fibre Channel disks for transaction oriented applications (Database, Messaging, ERP )

High Transaction Applications

(F/C)

File Services

(SATA)

Reduce procurement costs and increase profitability by choosing disk hardware technologies appropriate for customer workloads.

Page 24: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM CorporationIBM System Storage N series Business Solutions

Retention

SnapLock

• SEC-compliant disk-based WORM technology

• Provides non-erasable and non-rewritable data protection that helps enable compliance with government and industry records retention regulations

• An N series can be dedicated or partitioned to store WORM protected data

• SnapLock volumes are accessed via CIFS protocols

• Archival Application DB connects via FibreChannel or iSCSI and takes advantage of SnapManager availability features

Archival Server DB

Compliance Storage

E-Mail and ERP Applications

Reduce Administrative Costs by not introducing a new, dedicated platform to support WORM, Archival and Compliance

Page 25: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM CorporationIBM System Storage N series Business Solutions

Retention

NearStore Feature

• Data ONTAP maintains a fixed upper limit for concurrent SnapMirror and SnapVault transfers based on the type of disks the system has attached.

• Concurrent operations allow multiple data streams between two N series devices for the purpose of backup, data protection, disaster preparedness

• The NearStore (near-line) feature increases the maximum number of concurrent data streams (per storage controller)

• Notes: Concurrent data streams = a combination of SnapMirror and SnapVault and Open Systems SnapVault sessions

Concurrent data streams

Page 26: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM CorporationIBM System Storage N series Business Solutions

RetentionSnapVault

• Provides heterogeneous super-efficient hourly disk-based online backup

• Restore by periodically backing up a snapshot copy to another system

• Full volume copies of primary N series systems reside on backup system

• Incremental block changes are sent to backup system for efficient space management (Single Instance Storage)

• Enables hourly backups across LAN or WAN

N series secondary storage

N series primary storage

Moves a full copy to safe placeMoves incremental snapshots to safe place

Space efficient

Moves full copy

Incremental blocks

Page 27: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM CorporationIBM System Storage N series Business Solutions

RetentionOpen System SnapVault

• Provides heterogeneous super-efficient hourly disk-based online backup

• Restore by periodically backing up a snapshot copy to another system

• Full volume copies of primary N series systems reside on backup system

• Incremental block changes are sent to backup system for efficient space management (Single Instance Storage)

• Open systems agents available for AIX, Solaris, HP-UX, Linux and MS Windows

• Enables hourly backups across LAN or WAN

N series secondary storage

Open SystemUNIX, LINUX,

Windows

Moves a full copy to safe placeMoves incremental snapshots to safe place

Space efficient

Moves full copy

Incremental blocks

Page 28: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM CorporationIBM System Storage N series Business Solutions

Operation

Page 29: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM CorporationIBM System Storage N series Business Solutions

Operation

Service Levels – FlexShare Storage Optimization - Advanced Single Instance Storage

Centralized Management – Operations Manager

Reduced Administration – Disparate architectures vs. single architecture

Page 30: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM CorporationIBM System Storage N series Business Solutions

Operation

FlexShare

• Provides level of service for applications and protocols • Assign priorities to key applications in a mixed environment• Change priorities dynamically based on application needs

Test/Dev/QA

ERP/CRM SQL / Exchange / VMWare

High Priority Medium Priority

Low Priority

Page 31: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM Corporation

Operation Significantly improves physical storage efficiency and network

efficiency by enabling the sharing of duplicate data

Transparent to applications

Complements other space savings technologies

Site A, e.g. Branch Office

Network EfficiencyReduce amount of data that travels across the

network

A-SIS optimized storage

Site B, e.g. Central Site

A-SIS optimized storage

A-SIS

Page 32: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM CorporationIBM System Storage N series Business Solutions

Operation

Operations Manager

OM is a web or command line based administration utility with the following key benefits:

• Improve auditing and customer chargeback reporting

• Enable a centralized view of entire N series infrastructure

• Detailed Asset Management Reports• Quota Monitoring and Management• Utilization Chargeback Reports

• Simple Centralized Administration• Configuration Management

• Apply Business Policies to N series systems

• Role Based Access Controls • Flexible, hierarchical device grouping• SnapVault and SnapMirror Monitoring and Management

• Establish mirroring and vaulting relationships, monitor lag times and perform disaster recovery procedures

Page 33: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM CorporationIBM System Storage N series Business Solutions

Operation

Reduced Administration

Traditional Approach – Fragmented portfolios • 4 different operating systems• 4 different management tools• 4 different recovery tool suites• 4 different administrators

IBM N series

• 1 Enterprise Operating System

• 1 Enterprise Management Tool

• 1 Suite of Enterprise Recovery Tools

• 1 Administrator

1

2 3

4

High End SAN

Mid-Range SAN NAS

Compliance

1

Page 34: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM CorporationIBM System Storage N series Business Solutions

N series Conclusion

Unified Storage Architecture

Page 35: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM Corporation

N series and NAS Competition

Page 36: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM Corporation

All Competitors: N series Snapshots as Key Differentiator N series Performance: write-once, with no performance impact

– Competition: storage arrays read-write-write; hosts see 30-50% reduction in storage system performance

N series Flexibility: use Snapshot anytime, and frequently– Competition: performance impact is significant; reduces use of copy-out to

stabilizing a LUN for night-time tape backup N series Scalability: 255 traditional volumes, unlimited FlexVol

– Competition: Some may say “unlimited” copies, but performance degradation for many LUNs make it impractical

N series Management Overhead: Active data and Snapshot copies all in one easily managed volume

– Competition: Administrative burden to predict copy-out-area size; locate for optimum performance; what to do when they get full

N series User-driven Recovery - Integrated into active volume , end-user recovery– Competition: Copy-out snapshots mounted in “remote” places in file system

hierarchy - difficult or impossible for ordinary users to access

Page 37: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM Corporation

AXiCXi AX

EMC Technology OverviewPoint Solutions vs. Single Architecture

EMC: Centera

CLARiiON CX

DMX

Celerra

learn less … … do more

1 System and OS1 Replication Strategy1 Management Interface

CLARiiON DL

IBM N seriesUnified Networked Storage

Control Center™ Family of Mgmt Products

DARTHi-NAS

CentraStarCAS

OS:Networked Storage:

EnginuityHi-End SAN

FlareMid-SAN Lo-SANMid-iSCSI Lo-iSCSI

IPStor&FlareVirtual Tape

Lib.

Page 38: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM Corporation

EMC NAS OfferingLimited Architecture & Management, No Business Continuity

NS20 NS40/g NS80/g NSX

ManagementCelerra Mgr

Control Station PC Navisphere Mgr

Celerra Mgr Control Station PC

Navisphere Mgr

Celerra Mgr Control Station PC

Navisphere Mgr

Celerra Mgr Control Station PC

SymMgr

Availability Control Station PCSPOF

Control Station PCSPOF

Control Station PCSPOF

Redundant

Business Continuity

DR Only / No BC Protection

Async Replication

DR Only / No BC Protection

Async Replication

DR Only / No BC ProtectionAsync Replication

Complex DR/BC

Flexible NAS OnlyiSCSI target Only

NAS OnlyiSCSI target Only

NAS OnlyiSCSI target Only

NAS OnlyiSCSI target Only

Scalable NO upgrade NO upgrade Limited upgrade to 4 Data Movers

Forklift upgradeCX to DMX

Capable NO compliance NO compliance NO compliance NO compliance

Growth to 32TB to 80TB to 144TB to 336TB

CLARiiON or Symmetrix

Required

Page 39: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM Corporation

IBM N series vs EMC NS Series Software OfferingsIBM N series EMC NS Series

DataONTAPDART - NS Data Mover, RHL - NS Control StationFLARE - NS/CX backend

RAID-DP RAID-5, RAID-1/0, No Double Parity

Concurrent Protocols (FCP, iSCSI, NFS, CIFS, HTTP, FTP) Not Available

Telnet, FTP, SNMP, SMTP, NDMP TelNet, FTP, SNMP, SMTP, NDMP

FilerView Celerra Manager – Basic Edition

DataFabric Manager Celerra Manager – Advanced Edition

SnapManager Celerra Manager – Advanced Edition

FlexVol ( Thin Provisioning ) Celerra Automated Volume Management

Snapshot SnapSure

SnapRestore SnapSure

iSCSI iSCSI target only

FCP FCP

Clustered Failover Control Station Invoked

CIFS CIFS

NFS NFS

HTTP HTTP

Any workstation Microsoft Management Console

CLI CLI

SAN Manager Not Available

MultiStore (Vfiler) Not Available

Virus Protection Celerra Anti-Virus

IBM N series EMC NS Series

FlexClone Not Available

FlexCache Not Available

SnapLock Not Available

SnapMirror - Sync Not Available

SnapMirror - SemiSync Not Available

SnapMirror - Async Celerra Replicator – Async

SnapMover Celerra FileMover via API

SnapVault Not Available

LockVault Not Available

SyncMirror (High Availability) Not Available

Single Mailbox Recovery (SMBR) Not Available

SnapDrive Not Available

SnapValidator (FC, iSCSI, IP) Not Available

Open Systems SnapVault (OSSV) Not Available

MetroCluster (High Availability) Not Available

SecureAdmin Celerra Manager – Advanced Edition

Virtual File Manager (VFM) Nested Mount Filesystem

?? OnCourse

?? Celerra MPFS/MPFSi (MultiPath File System)

Page 40: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM Corporation

EMC CX4 Announce – August 4, 2008 EMC announced 4 models of the CLARiiON CX4: Virtual Provisioning (adopted from Celerra) 64-bit processing, (AMD multi-core technology) Customer-installable / serviceable (from consumer products) Future availability of SSD (sourced from Emulex) and disk spin-

down (from Quantum)* Tucci: CIOs’ No. 1 problem is complexity; change is too difficult;

appliances address this challengeN series Competitive Positioning & Model Alignment:

IBM N series EMC CLARiiON CX4 Series

N3600, N5200 CX4-120, 120 disks, 4+4 FC/iSCSI, 16 ports max (FC), 6GB cache

N5300 CX4-240, 240 disks, 4+4 FC/iSCSI, 20 ports max (FC), 8GB cache

N6040 (8/26 announce), N5600 CX4-480, 480 disks, 8+4 FC/iSCSI, 24 ports max (FC), 16GB cache

N6070 (8/26 announce) CX4-960, 960 disks, 8+4 FC/iSCSI, 32 ports max (FC), 32GB cache

Page 41: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM Corporation

CLARiiON Realities Ahead of Symmetrix in yoy growth (2007 - Q1

6%, Q2 8%, Q3 9%, Q4 15%; 2008 Q1 19%) – Accelerating demand

Complementary systems (e.g., Celerra, Centera, DL) are extremely successful

Growing iSCSI share with AX platforms Dell/EMC still positive, but momentum is

significantly slowing Most successful mid-range SAN platform in

terms of market share Well marketed and Trusted brand Foundational to a broad range of successful

solutions

Perception is key.

•Behind the curve in functionality

•Difficult to deploy and maintain

•Not well differentiated

•Major operational challenges and software limitations

•Expensive, low value

Page 42: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM Corporation

““Ultra” scalableUltra” scalable Hardware features

More manageableMore manageable Navisphere Analyzer and QoS, PowerPath Breadth of configuration/optimization

parameters (via Navisphere) Optional software and appliances

More robust than othersMore robust than others• Cache de-staging to disk• Fast failover / failback

Better for VMwareBetter for VMware• Special access through ownership• Closer affinity through access• Validation through TBs

Perspectives on CLARiiON messaging

•N series has equally powerful hardware•Performance relies heavily on ongoing tuning; complex management •Optional software is often incompatible and inept•Appliances don’t play well together and increase TCO•5x9s is an expensive EMC-only service contract; not available from OEM suppliers•VMware is independent and vendor-neutral

Page 43: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM Corporation

Perspectives on VMware and CLARiiON

Gives EMC an integral footprint in the server architecture

– No longer a storage-only vendor

– Ability to claim “complete solution provider” status in terms of virtualization technology, integration, and services

Creates the perception of favored status and deeper integration

Paves the way for greater success

NetApp Internal Use Only. Restricted to NetApp Employees and Contractors under NDA.

•Exploiting perceptions of “favored status” with customers and in marketing•Investing in VMware integration projects and touting futures•Claiming market leadership in storage for VMware

Reality: VMware is vendor-agnostic. No validation of EMC’s leadership claims. Server virtualization market is poised for a

shake-up.

Page 44: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM Corporation

N7900N5200/N5300/N5600 N7700N3300/N3600 N5300G N5600G N7700G N7900G

HP Technology Overview

N seriesN seriesFC & IPFC & IP

N series:N series:Architectural Simplicity

Multiple Concurrent ProtocolsIntegrated Mgmt, DR, BC, ILM, B2D, …

HP FCHP FC

HP IPHP IP

N series GatewayHP, IBM, HDS, SUN

StorageWorks

DL100/ML110

StorageWorks

DL350

StorageWorks

DL380 G4

MSA 1000

StorageWorks

DL380 G4NAS/SAN Fusion

RISS(NENR)

MSA 1500/2000

MSA 1500cs

EVA4000

EVA6000

EVA8000

MSA 1500i = iSCSI Only

XP10000

XP12000

No Native FC / IP Simultaneous access Forklift Upgrades within product

families Performance Penalties for RAID6 and

Snapshotting NAS Capability through WSS or Linux

only OEM’d XP Range from Hitachi

HP: HP: Focused on Server SalesFocused on Server Sales

NotNot Storage! Storage!

MSA 20

MSA 30

= Disk EnclosuresOnly

Page 45: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM Corporation

Competitive Alignment

EMC CLARiiON Series

EMC DMX-3 SeriesAX150 CX3-10 CX3-20 CX3-40 CX3-80

60 Disks 30 TBs

120 Disks 59 TBs

240 Disks119 TBs

480 Disks237 TBs

950 DMX-3 360 Disks

180 TBs240 - 2,400 Disks

1054 TB

12 Disks6 TBs

4 FCP / 4 iSCSI 4 FCP / 8 iSCSI 4 FCP / 8 iSCSI 8 FCP4 iSCSI

64 FCP / 48 iSCSI16 FCP / 10 iSCSI

HP MSA/EVA Series

HP XP Series

XP10000 XP12000240 Disks

69 TBs32 – 1,148 Disks

332 TBs

240 Disks120 TBs

112 Disks56 TBs

56 Disks28 TBs

14 Disks4 TBs

42 Disks12 TBs

56/96 Disks16/64 TBs

HP NAS/iSCSI supportRequires an appliance

MSA500 MSA1000 MSA1500

EVA4000 EVA6000 EVA8000

IBM N series Family

N3300 N3600 N5200 N5300 N5600 N7700 N7900104 Disks104 TBs

168 Disks84 TBs

252 Disks252 TBs

504 Disks336 TBs

840 Disks840 TBs

1176 Disks1176 TBs

4 FCP / 4 iSCSI 8 FCP / 8 iSCSI 4 FCP / 4 iSCSI 8 FCP / 8 iSCSI 16 FCP / 12 iSCSI 16 FCP / 12 iSCSI

68 Disks68 TBs

4 FCP / 4 iSCSI

Page 46: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM Corporation

Beyond the Midrange Storage Competition HP

EVA8000 N5300 N5600 EMC CX3-80

Max Capacity 120TB 252TB 336TB 239TB

RAID 6 (RAID-DP) Yes YES YES Yes

Low Overhead Snapshots No YES YES No

Max Snapshots unknown 127,500 127,500 300

Thin Provisioning No YES YES No

Protocol Support FCPFCP, 10Gb iSCSI, NFS,

CIFS

FCP, 10Gb iSCSI, NFS,

CIFSFCP

Upgrade Path to High-End System

Rip, Replace & Retrain Seamless Seamless Rip, Replace

& Retrain

N series has greater scalability and better data protection Unmatched SnapshotTM, FlexVolTM and RAID-DP technologies Versatility to go beyond FC-SAN without a gateway product

Page 47: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM Corporation

Competing Against HPWhy N series vs. HP?

– Greater data integrity via RAID-DP & Maintenance Center – Lower total cost of ownership

• Easier to install, configure, and deploy • Flex and Snap-suite dramatically simplify administration and allocation of storage • Staff only needs to be trained in one technology

– Greater versatility • Integrated multi-protocol SAN/NAS in one box • Simultaneous FCP & iSCSI in one box

– Common compatible architecture across the entire product range

• Full interoperability and upgradeability across entire range product range • Staff only needs to be trained in one technology

– Superior host and application software support – Superior solution completeness – Superior software technology

Page 48: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM Corporation

HDS Technology Overview

TagmaStore WMS and AMS Introduced 7/2005 Replacement for Thunder 9200/9500 series WMS100, AMS200 and AMS500

– AMS1000 announced in April 2006– Not upgradeable between platforms

Configuration flexibility and scalability High availability – Support for RAID 6 Native NAS and iSCSI

– CIFS and NFS, Linux Kernel, Integrated software

RAID 6 (30% performance hit) Cache Partition Manager for high

performance applications• Turn Controller Mirroring On/Off• Specify unique stripe sizes

RoHS compliant

Content

Archive

VTL Open

WMS100

AMS200AMS500 AMS1000

HDSHDSFC & IPFC & IP(midrange)

ProtecTIER VTL

NSC55 USP100/600/1000

HDSHDSFC & IPFC & IP(enterprise)

(NSC and USP have virtualization options)

TagmaStore USP USP100, USP600, USP1100 - field upgradeable Supports internal array storage (330TB) Supports “external” heterogeneous storage 32PB

– HDS, Sun, HP, EMC, IBM Host ports (192 FC, 96 FICON, 96 ESCON, 32

NAS, 32 iSCSI) High performance

– Up to 1.9 million cache read hits per second– Up to 81GB/sec throughput

NSC55 for benefits of USP in mid-range market– Mission Critical, 100% data availability– z/OS support– Simplified Heterogeneous management – Data Migration between tiers– Substantial BC/DR requirements– Aggressive consolidation – Significant multi-tasking workload

Page 49: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM Corporation

N series Unified Architecture, Open ProtocolsCorporate Data Center Distributed locations

N3700

Home Dirs

CIFS

Unix , Linux

LAN

Regional Data CenterN5200

Gateway

WindowsServers

Exchange &SQL Server

iSCSI

LAN

UNIX®Servers

Linux®Servers

WindowsServers

Exchange

CRM

ERP

Home Dir,Network Shares,

Archive DataUtilizing

SATA drives

SQL Server

Windows®Servers

N7800w/ FC

iSCSI

CIFS, NFS

IP SAN

FC SAN WAN

LAN

NAS Protocols

N5500w/ SATA

DS4800One architecture, One management interface

Page 50: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM Corporation

IBM N Series Key Competitive Advantages: IBM has a single family of software (Data ONTAP) that works across all the N series offerings. This single architecture: Reduces training Reduces process, makes business more agile Takes advantage of synergy between primary and secondary

storage Lowers Total Cost of Ownership

All N series products offer the same software options, system and storage management tools, and multiprotocol (NAS, IP SAN, FC SAN; FC and SATA drives) functionality

N series Snapshot technology provides greater flexibility More copies online (up to 255) provides lower recovery time Not copy on write, so no performance degradation Space efficient, non-writable, non-corruptible Backups while active file system is in production

Page 51: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM Corporation

N series Snapshots as Key Competitive Differentiator

N series Performance: write-once, with no performance impact N series Flexibility: use Snapshot anytime, and frequently N series Scalability N series Management Overhead: Active data and Snapshot

copies all in one easily managed volume N series User-driven Recovery - Integrated into active volume ,

end-user recovery

Page 52: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM Corporation

IBM N Series vs. EMC EMC’s primary strength is in it’s market leadership EMC will work hard to get you to focus on performance

Know two questions to deflect the performance issue Key N series Technologies EMC does NOT have:

FlexClone - space efficient copies of databases and volumes for test, dev, and QA

Performance Enhanced RAID6 - for superior protection from a 2 disk failure

Single OS - across entire platform for reduced administration and training, and for consistent software functions

SnapManager - application aware integration tools for Oracle, Exchange, and SQL

True Multiprotocol - NAS, SAN, iSCSI, and Archive storage solutions from a single platform

Page 53: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM Corporation

IBM N Series vs. HP HP can’t simultaneously access FC and IP HP requires “Forklift” upgrades, even within product families HP has performance penalties for RAID6 and Snapshots HP NAS capability through WSS or Linux only HP wants to focus on selling servers, with little focus on developing

innovative storage technologies

Page 54: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM Corporation

Review questions• The SnapRestore function allows customers

• To restore SnapShots (files or complete volumes) rapidly• To mirror source to target changes• To restore an entire SAP environment• To provide virtualized storage pools

• The key value of the N series is?• The flexibility to attach SAN devices via NAS, iSCSI, and FC simultaneously• Price/performance and capacity• Rich set of software functionality• The ability to provide data retention and compliance applications

• FlexVol and FlexClone are examples of ?• Mirroring solutions• A standard offering and a priced option• 2 standard offerings• 2 priced offerings

• MetroCluster is the ability to • Provide multiple cluster nodes in an engineering scientific application• Virtualize storage in Cluster 1600 offering• Failover of system data from primary system to backup system • Failover large applications and Unix operating systems

Page 55: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM Corporation

Additional Information

Page 56: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM Corporation

Celerra NS (Network Server)Celerra NS (Network Server)NS20/NS40/NS80 example:

Control Station

SPBSPA

Active/standbyor active/active

Control station PCLinux-based

CLARiiON CX3

DAE15 drives / 6 min

Data Mover

Data Mover

Modem Analog modem(Call home, under

floor)

Data center floor

FC switch for “g” model

SPOF

Appliance Implementation

Disk Access Enclosure

SPS (stand-by power supply)

•Multiple hardware nodes•Excessive power consumption•Three incompatible OSs•Extraneous software•Complicated management and maintenance•Not particularly stable, points of failure•Management inconsistencies•Functionality gaps

Reality: Not really unified storage

Page 57: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM Corporation

Inconsistent Snapshot Functions

DART has two different mechanisms for creating snapshots:DART has two different mechanisms for creating snapshots:NAS Copy on first write technique–usual EMC three-I/O write penalty Slow Restores–requires copying blocks back from SavVol License in base price and includes volume restoreiSCSI File versioning technique (similar to WAFL snapshot)

– Up to 2000 snapshots per LUN iSCSI also supports “writeable snapshots” LUNs cannot exceed 2 TB

BitmapUnchanged = 0,

Changed = 1DB0 0DB1 0DB2 1DB3 0DB4 0DB5 1DB6 0DB7 1DB8 1DB9 0DB10 1DB11 0

Save original DB10

SavVol

Save original DB8Save original DB7Save original DB5Save original DB2

Production file system (PFS)Data Blocks

DB0DB1DB2DB3DB4DB5DB6DB7DB8DB9

DB10DB11

Write over PFS DB8Write over PFS DB10

Read PFS DB0

Write over PFS DB7Write over PFS DB5Write over PFS DB2

Read PFS DB1Read PFS DB0

Read PFS 3

Transactions bound for

PFS

Page 58: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM Corporation

EMC CLARiiON Family

AX150iAX150i CX3-10CX3-10 CX3-20CX3-20 CX3-40CX3-40 CX3-80CX3-80

Host Ports 4 iSCSI ports only 4 FC/ 4 iSCSI ports 4 FC / 8 iSCSI ports 4 FC/ 8 iSCSI ports 8 FC ports only

Enclosure Architecture Loop -Design Loop -Design Loop -Design Loop -Design Loop -Design

Disk Options SATA only FC and SATA FC and SATA FC and SATA FC and SATA

GrowthUp to 12 disks

to 6TBs

Up to 60 disks

to 30TBs

Up to 120 disks

to 59TBs

Up to 240 disks

to 119TBs

Up to 480 disks

to 237TBs

Management Navisphere Manager Navisphere Manager Navisphere Manager Navisphere Manager Navisphere Manager

Availability

Redundant optionActive / Active

No Hot-Swappable Components

RedundantActive / Active

RedundantActive / Active

RedundantActive / Active

RedundantActive / Active

Business Continuity Not Available

Replication Manager/SE

FCP Async Only

FCP: MirrorView Sync

MirrorView

FCP: Async and Sync

MirrorView

FCP: Async and Sync

MirrorView

FCP: Async and Sync

Flexible FCP and iSCSI block FCP and iSCSI block FCP and iSCSI block FCP and iSCSI block FCP and iSCSI block

Scalable (12) SATA Disks only Forklift upgrade from CLARiiON AX150i

Data-in-Place Upgradeable

Data-in-Place Upgradeable

Data-in-Place Upgradeable

Capable NO compliance NO compliance NO compliance NO compliance NO compliance

Page 59: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM Corporation

HP EVA Strengths and Weaknesses HP EVA Strengths

– Innovative RAID virtualization technology (Vraid) allows LUNs to be virtualized over pooled disks

– Demand-allocated virtual capacity free snapshots – Mix FC and “FATA” disks in same enclosure – Integrated management and configuration tools

HP EVA Weaknesses – No fast restore capability for snapshots – Demand-allocated snapshots silently dropped when out of space – High Availability with CAVA solution – complex, inefficient, inflexible off-box

remote mirroring– Incomplete Disk Protection Utilization

- No complete double-disk failure protection (i.e. RAID-DP)- Requires double the spare disk space using “distributed sparing” technique- Vraid defeats built-in disk load-balancing abilities

– No upgrade path to or from any other HP array family – No QoS workload prioritization (such as FlexShare) – No native multi-protocol support ( NAS or iSCSI)– Command View EVA cannot manage any other HP storage array

HP EVA4000HP EVA6000HP EVA8000

Page 60: IBM System Storage™ N series – Unified Storage Solutions © 2007 IBM Corporation IBM System Storage – N series This document is for IBM and IBM Business

IBM System Storage™ N series – Unified Storage Solutions

© 2007 IBM Corporation

HDS Key Strengths and Weaknesses TagmaStore Strengths

– Quality hardware and high performance – Virtualization within subsystem with Virtual Partition Manager – Ultra resilient, scalable architecture for high availability– Large cache and internal bandwidth supports high transaction

workloads– Full line of remote replication solutions with Universal Replicator

TagmaStore Weaknesses – No upgrade path from lower-tier products– Software quality not always up to hardware quality levels– Expensive virtualization app (Virtual Partition Manager) – Performance of copy-on-write snapshots, RAID-6 – Hitachi, Ltd. owns the design, HDS has limited control