erg environmental - innovation and leading technology · innovation and leading technology sr120v...
TRANSCRIPT
InstallatIon guIde2017-04-17
InnovatIon and leadIng technology
NEXT GENERATION™ REcyclERs SR120V, 180V & 240V
InnovatIon and leadIng technology
2SR120V ,180V & 240V Installation guide
Tools required ___________________________________________________________ 3
Parts required ___________________________________________________________ 3
Un-packaging the unit ____________________________________________________ 3
TAblE Of cONTENTs
Page
sEcTION 1
How to install a Solvent Saver™ Recycler _____________________________________ 4
Installing the Ground wire _________________________________________________ 4
Electrical connection ______________________________________________________ 4
Installation drawing _______________________________________________________ 5
General Arrangement _____________________________________________________ 6
Warranty & Contact Information ____________________________________________ 7
Our mission _____________________________________________________________ 8
sEcTION 2
fINAl sEcTION
SECTION 1
InnovatIon and leadIng technology
3SR120V ,180V & 240V Installation guide
PARTs REQUIRED
• Main breaker per classification area (See General Arrangement Drawings) - 600 or 480 Volt 3 Phase Power - Install at 5 - 6 Ft from units at least - 18” above the ground
• Inlet Compressed Air Line ½’’ min. next to unit
• Inlet Water Line ½’’ min. next to unit (option)
UNPAcKAGING THE UNIT
Step 1 : Carefully inspect the shipping carton for any signs of transport damage.
Step 2 : Begin by removing the plastic wrap and the Styrofoam then remove the wood plate behind the unit protective condenser.
Step 3 : Carefully remove your solvent recycler from the shipping carton. Remove the four straps from the bottom of the solvent recycler screwed to the palette.
Step 4 : Remove the unit from the palette and place it in the general area for installation.
You are ready to begin with the installation of the solvent recycler.
SECTION 1
InnovatIon and leadIng technology
4SR120V ,180V & 240V Installation guide
ElEcTRIcAl cONNEcTIONs Step 1 : Now we are ready to have the electrician wire the solvent recycler for model SR120V connect to 480 V or 600 V - 3 phases (as per name plate on the unit) to the electrical junction box that is provided in the back of the unit. The 32 gallons recycler requires 25 A.For model SR180V connect to 480 volts or 600 volts 3 phases (as per name plate on the unit) to the electrical junction box that is provided in the back of the unit. The 48 gallons recycler requires 30 A.For model SR240V connect to 480 V or 600 V 3 phases (as per name plat on the unit) to the electrical junction box that is provided in the back of the unit. The 63 gallons recycler requires 30 A. For all these models, please refer to the electrical schematic found in the manual.For units that comes with a step up transformer the transformer must be located outside the explosion proof room in a safe non hazardous location.Then connect a ground wire to the back of the unit and use the ground wire with a clip to ground the 55 gallons / 205 litres drum. Step 2 : connect to the back of the unit the air you need an ½’’ air line, we suggest to put a filter regulator and adjust the air pressure on the regulator to 90 PSI.Step 3 : You need to connect the clean outlet and then used solvent inlet located in the back of the unitStep 4 : If the units comes with nitro cellulose package connect to the back of the unit a ½ water line.
Note : Please Review the “General Arrangement” Drawing. MAKE sURE All cODE REQUIREMENTs ARE fOllOWED.
You are now ready to follow the Start-up Process. Please follow the ISTpure Start-up
2
1
3
SECTION 2
InnovatIon and leadIng technology
5SR120V ,180V & 240V Installation guide
fINAl sEcTION
General arrangement
Note : the SR240 is not CSA certified
gen
era
l a
rr
an
gem
ent
Clas
sific
atio
n zo
nes
as p
er :
A )
NFP
A 33
stan
dard
for s
pray
app
licat
ion
usin
g fla
mm
mab
le a
nd co
mbu
stib
le m
ater
ials
, sec
tions
4.3
.5B)
Int
erna
tiona
l fire
cod
e, c
hapt
er 3
4 fla
mm
able
and
com
bust
ible
liqu
ids 3
403.
1.1
Zone
requ
irem
ents
app
ly to
bot
h gu
n cl
eane
rs a
nd re
cycl
ers t
oget
her a
nd st
and
alon
e.
4160
Indu
strie
l Blv
d. L
aval
, Qu
ebec
, H7
L 6H1
Tel.:
1 8
77 6
24-8
202
/ 450
963
-440
0 Fa
x : 4
50 9
63-5
122
Inte
rmed
iate
mix
roo
m
lege
nd
thre
e si
des
mix
roo
mFr
ee s
tan
din
g m
ix r
oom
enti
re s
yste
m o
uts
ide
mix
roo
men
tire
sys
tem
insi
de
mix
roo
m
Clas
s 1
- Div
1
Clas
s 1
- Div
2
Clas
s 1
- Div
2 1
8’’ H
igh
only
EXC
LUSI
VE R
IGH
TS
THIS
D
RAW
ING
IS
TH
E EX
CLU
SIV
E PR
OPE
RTY
OF
ISTP
UR
E,
INFO
RMAT
ION
S CO
NTA
IN
HER
EIN
C
AN
BE
U
SED
O
NLY
W
HEN
SP
ECIF
ICA
LLY
AU
THO
RIZE
D
BY
ISTP
UR
E .
POSS
ESTI
ON
O
F TH
IS
DRA
WIN
G D
OES
NO
T A
UTH
ORI
ZED
USE
FO
R TR
AN
SMIS
SIO
N T
O A
NY
OTH
ER O
RGA
NIZ
ATIO
N.
InnovatIon and leadIng technology
6SR120V ,180V & 240V Installation guide
fINAl sEcTION
General arrangement (cont’d)
gen
era
l a
rr
an
gem
entIn
for
mat
Ion
Co
deS
Ele
ctri
cal
Re
qu
ire
me
nts
Air
Re
qu
ire
me
nts
Wa
ter
req
uir
em
en
ts (
If n
ee
de
d)
Am
p D
raw
list
ed
fo
r e
nti
re u
nit
— in
clu
din
g m
oto
r a
nd
he
ati
ng
ele
me
nt
ISTpure
off
ers
a c
om
ple
te lin
e o
f sp
ray g
un c
leaners
and s
olv
ents
recy
clers
that
confo
rm t
o t
he r
equirem
ents
of
:•
NFPA
-33 S
tandard
for
spra
y a
pplic
ation u
sin
g fl
am
mable
and
com
bustible
mate
rials
.•
NFPA
-30 fl
am
mable
and c
om
bustible
liq
uid
code
• IF
C : Inte
rnational Fire C
ode
The r
ecy
cler
has
been c
ert
ified a
nd lis
ted :
• U
L 2
208 s
tandard
for
solv
ent
dis
tilla
tion u
nit
The r
ecy
cler
has
been r
evie
wed a
nd a
ppro
ved b
y :
• CSA
for
U.S
. &
Canada r
equirem
ents
report
#15
4896
Confo
rmity o
f all
these r
equirem
ents
is d
ependent
upon t
he m
anner
in w
hic
h t
he
equip
ment
is insta
lled. T
he c
ontr
act
or
will
make c
eta
in t
hat
all
of th
e e
lect
rica
l w
irin
g
and c
onduit, pip
ing, gas s
upply
, ro
of
penetr
ations, auto
matic
fire
pro
tect
ion s
yste
ms,
and the loca
tion o
f th
e e
quip
ment w
ithin
the b
uild
ing a
lso c
onfo
rms to the c
ited c
odes
and t
he o
ther
refe
rence
s.
Mo
dE
LF
ull
lo
ad
Am
p d
raw
L
oc
ati
on
No
n-c
lass
ifie
d
are
aIn
mix
ro
om
/cl
ass
ifie
d a
rea
22
0V
48
0V
60
0V
SR
30
11
.7—
—
• G
en
era
l p
urp
ose
d
isco
nn
ec
t
• M
in. 5
ft
aw
ay
fr
om
un
it
• M
in 1
8’’
off
th
e
flo
or
Exp
losi
on p
roof
dis
connect
re
quired
SR
60
23
.4—
—
SR
12
0—
14
.51
1.3
SR
18
0—
20
.81
5.0
SR
24
0—
24
.81
9.5
ItE
MA
ir L
ine
S
pe
cifi
cati
on
scf
mN
ote
s
SR
30
V-6
0V
3 / 8’’
@ 1
00 p
si5
Fact
ory
set
at
85-9
0 ps
i
SR
12
0V
-18
0V
½’’
@ 1
00 p
si10
SR
12
0V
-18
0V
½’’
@ 1
00 p
si10
SR
24
0½
’’ @
100
psi
10
oil M
od
EL
Ca
pa
city
de
scri
pti
on
SR
30
10 li
ters
oil
ISTp
ure
Ther
mic
Hea
t Tr
ansf
er O
il
Part
# 3
3006
6 —
4
lite
rs
Part
# 3
3006
7 —
10
liter
s
Part
# 3
3006
8 —
20
liter
s
SR
60
20 li
ters
oil
SR
12
055
lite
rs o
il
SR
18
065
lite
rs o
il
SR
24
013
0 lit
ers
oil
Re
cycl
er
Ba
gs
Mo
dE
LP
art
nu
mb
er
SR
30
30
00
06
SR
60
30
00
19
SR
12
03
00
00
8S
R 1
80
30
00
09
SR
24
03
00
01
0
Mo
dE
LW
ate
r L
ine
S
pe
cifi
cati
on
sN
ot
ES
SR
12
0V
SR
18
0V
SR
24
0V
1/2
’’ @
50
psi
To o
btai
n a
stea
dy p
ress
ure
a w
ater
reg
ulat
or
and/
or a
pre
ssur
e bo
oste
r co
uld
be a
dded
to t
he
mai
n w
ater
line
4160
Indu
stria
l Blv
d. L
aval
, Que
bec,
H7L
6H1
Tel.:
1 87
7 6
29-8
202
/ 450
963
-440
0 Fa
x : 4
50 9
63-5
122
ExcL
usI
vE r
IgH
TsTh
is d
raw
ing
is t
he e
xclu
sive
pro
pert
y of
IST
pure
and
inf
orm
atio
ns
cont
aine
d he
rein
can
be u
sed
only
whe
n sp
ecifi
cally
aut
horiz
ed b
y IST
pure
. Po
sses
sion
of t
his d
raw
ing
does
not
aut
horiz
e us
e no
r tra
nsm
issi
on to
any
ot
her o
rgan
isat
ion.
dA
tA &
SP
EC
IFIC
At
IoN
S
WARRANTy INfORMATION / TEcHNIcAl AssIsTANcE
www.istpure.comOr visit us at :
Note : the SR240 is not CSA certified
InnovatIon and leadIng technology
7SR120V ,180V & 240V Installation guide
WARRANTy INfORMATION / TEcHNIcAl AssIsTANcE
www.istpure.com
TEL.: 1 877 629-8202 & 450 963-4400 FAX : 450 963-5122
For more information, prices or technical assistance,contact your local IST distributor or call / fax our
Consumer Information Numbers :
Or visit us at :
ISTpure is a registered trademark of :
www.istpurecom www.istsurface.com 2017
-04-
17
T : 1 877 629-8202F : 450 [email protected]
4160 Industriel Blvd.Laval, QuebecH7L 6H1 Canada
ISTpure is a registered trademark of
International Surface Technologies
InnovatIon and leadIng technology
Industrial Applications :
• Aerospace• Auto Assembly• Body Shop
• Bus• Fiberglass• Flexography
• Furniture• General Metal• Printing
• Rail Car• Truck
INNOVATIVE AND LEADING TEChNOLOGY
Founded in 1978, IST is a North American leader in solvent recycling systems, paint gun washers, industrial cleaning equipment and automated sandblasting systems. The company’s success is based on its unwavering commitment to technical excellence, world-class manufacturing and unparalleled customer service.
Working closely with qualified distributors and paint manufacturers, ISTpure offers systems, products and technologies that set the quality standard in a wide range of cleaning and recycling solutions. ISTpure provides equipment for a wide range of industries for cleaning paint equipment including the automotive and industrial solvent recycler series that minimizes solvent usage and disposal.
ISTpure’s ongoing investment in paint gun cleaning, solvent recycling, industrial cleaning and sandblasting systems will continue to provide innovative solutions to a diverse global market. Call today for product information, to request a demonstration or for a free quote.
• Significantly reduce waste.• Major reduction in waste related expense.
• Major savings in reduced material purchases.• Reduced fire & spill hazards.
benefits of Owning a Solvent Recycler Include :