Side 2 16 Install Standard Control Panel or Intel® Local Control Panel (optional) Slide the control panel fully into the server system until it clicks into place. C Feed the control panel cables into the chassis opening. B Connect the USB and data cables to the replacement control panel as shown. A Connect the two cables to the USB and control panel connectors on the back side of the backplane as shown. D Install the mini control panel filler panel. E Remove the filler on the right as shown. B Press the latch at the back of the mini control panel and push the control panel forward to release it from the chassis. A Slide the mini control panel out through the front of the server system. C Remove the Mini Control Panel Install the Standard or Intel® Local Control Panel Latch Mini Control Panel Local Control Panel A C B Filler Panel Local Control Panel Filler Panel B A Backplane C D E 17 Install Processor Air Duct Use care to avoid pinching system cables. Processor Air Duct 18 Install Add-in Card (optional) A Remove filler panel from the add-in card slot. B Insert add-in card until it seats in riser connector. C Secure the add-in card with screw as shown. D Remove the screw as shown. CAUTION: Observe normal ESD precautions when installing the add-in card. Riser Connector REMOVE Filler Panel D B A C 19 Install Add-in Card Riser Assembly Riser Card Edge Connector Press down uniformly until the two hooks on the rear of the PCI riser assembly engage the chassis back panel slots. The riser card will seat into the matching riser socket on the server board. B PCI Riser Socket Chassis Slots (2) Hooks (2) Processor Air Duct Air Duct Slot Position riser card edge connector over the server board riser socket and align the two hooks in the riser with the slots at the back of the chassis. A Note that the riser assembly card edge installs in the slot in the processor air duct. 12 Install Passive System (Product Code: SR1625UR) Components ...for an Active System, go to Step 11 Connect SATA cables from passive midplane board to server board as shown. Route cables under the retention tab and alongside the power supply as shown to allow clearance for a full- height PCI add-in card. A B Passive Midplane Power Distribution Board Cover A B 0 3 2 1 4 5 Power Supply Cable Retention Tab CAUTION: It is critical that you connect the SATA data cables correctly from the SATA midplane to your server board or RAID Controller card. Failure to do so may result in data loss. 4 5 6 7 1 2 3 Passive Midplane SATA Connectors A 0 Server Board 14 Install Optical Device Insert the optical drive into chassis opening and push all the way until it stops. B Install the plastic guide onto the back of the drive and attach with two screws as shown. A A IMPORTANT NOTE: If you do not install a device at this location, install the optical device bay filler panel shown below. This is required to maintain proper system cooling. B 20 Install Rack Handles 21 Install Top Cover Note: Security screw re-installation is optional. A Place cover as shown, slide forward to engage recessed edge at front of cover. Make sure latch is locked. A Recessed Edge 11 Install Active System (Product Code: SR1625URSAS) Components ... for a Passive System, go to Step 12 Remove Power Distribution Board Cover (optional) This step is only necessary if you are installing the optional RAID Battery Backup Unit (BBU). Power Distribution Board Cover Check RAID BBU Battery Connection Install RAID Battery Backup Unit (optional) Install RAID DIMM and RAID Activation Key (optional) Install Power Distribution Board (PDB) Cover The RAID BBU has an internal battery power cable. Open the BBU case lid as shown. A If the battery power cable is not connected, connect the cable now. Close and latch the BBU case lid. B A B The RAID BBU has two hooks on the underside. Align these hooks with the matching chassis tabs, then slide toward the power supply to lock into place. A Connect the power cable between the BBU and the midplane board as shown. B Midplane RAID BBU Connector Chassis Tab(2) Power Supply Battery Backup Unit A B Chassis Standoff PDB Power Distribution Board Power Distribution Board Cover A B Insert the Intel ® RAID Activation Key into the midplane board socket as shown. Make sure the key snaps into the socket. A Open RAID mini DIMM socket levers and insert connector edge of mini DIMM into socket until levers close and snap into place. B Backplane Board not shown for clarity Intel ® RAID Activation Key Socket RAID Mini DIMM Socket RAID Mini DIMM RAID Key Open Levers B A Midplane Board A B Install power distribution board cover by aligning with the power distribution board and the matching thumbscrew hole. Note that the thumbscrew attaches to a chassis standoff underneath the PDB. If the PDB is not installed correctly, the thumbscrew will not align with the standoff. Power Distribution Board Cover Note: Standard and Intel ® Local Control Panel install the same. 22 Install Bezel (optional) Mini Control Panel Bezel Select the bezel that matches your control panel and install as shown. Intel® Local Control Panel Bezel Standard Control Panel Bezel Front Panel Controls and Indicators Intel® Local Control Panel Standard Control Panel A NIC2 Activity LED B. NIC1 Activity LED C. Power/Sleep Button D. Power/Sleep LED E. Hard Drive Activity LED F. Status LED G. System ID LED H. System ID Button I. Reset Button J. USB 1.1 Port K. NMI (recessed) Button L. Video A USB 1.1 Port B. LCD Display C. Menu Control Button - Up D. Menu Control Button - Down E. Menu Control Button - Left F. Menu Control Button - Enter G. ID LED H. Power/Sleep LED I. Power/Sleep Button J. System Status LED K. NIC 2 Activity LED L. NIC 1 Activity LED M. HDD Activity LED N. Reset Button O. USB 1.1 Port B A D C G E F Mini Control Panel A USB 1.1 Port B. System ID LED C. System Status LED D. Power/Sleep LED E. Power/Sleep Button F. NMI Button G. System ID Button O M L K J H I N G C D E F B A J I L K B A F G H E D C 24 Software BIOS, Drivers, and Operating System Installation C. Install your Operating System: Use the instructions provided with the RAID controller and with the operating system. D. Install Operating System Drivers: With the operating system running, insert the Intel ® Server Deployment Toolkit CD. If using a Microsoft Windows* operating system, the Express Installer will autorun and allow you to select the appropriate drivers to install. On other operating systems, browse the CD folders to locate and install the driver files. E. Install Intel® System Management Software (optional): Download the latest version of the Intel ® System Management Software from http://www.intel.com/go/servermanagement and use the instructions provided at that link to install the software. A. Update the System Software: 1. Boot from the Intel ® Server Deployment Toolkit CD. 2. Use the Wizard to access the latest versions on the Internet and update the BIOS, firmware, FRUSDRs, and Intel ® RMM3. Note: You can also use downloaded files on a USB key. B. Configure your RAID Controller: If using a RAID card, use the instructions provided with the RAID controller. If using on-board RAID, you must activate RAID in the BIOS setup. See the Intel ® Server Board S5520UR Technical Product Specification for more information. Note: Rack handles are required to install the bezel. For detailed instructions, see the Service Guide. Install processor air duct as shown making sure the front edge of the duct aligns correctly with the notches on the fan module. USB Cable Data Cable Note: To install hard drives in drive locations 6 and 7, you must remove the filler panel. 13 Install Hard Drives/Carriers Remove the drive carrier by pressing in on the green latch, pulling out on the black lever and sliding the drive carrier out. Repeat these steps for each installed hard drive Note: Carrier lever must be held in the FULLY OPEN position to install into the chassis. Slide carrier into chassis until it clicks, then close the lever. A Remove the plastic air baffle and save for future use. B Install the hard disk drive as shown. C Install hard disk drive assembly into chassis opening. D CAUTION: If you install less than eight drives or devices, empty drive bays must be occupied by carriers with baffles or with a filler panel provided for drive locations 6 and 7 to maintain proper system cooling. Drive 0 Primary Hard Drive Numbering Diagram 3 1 2 7 6 4 5 0 Attach with four screws. C Remove only when installing hard drive device. Keep for future use B Press in on the green latch to open lever. A D Note: To install hard drives in drive locations 6 and 7, remove the filler panel. AXXHERAIL2 Cable Management Arm Tool-less Rail Kit AXXBASRAIL13 Basic Slide Rail Kit ASR1550BEZ Bezel for Standard Control Panel Optional Accessories and Order Codes AXXBRACKETS AXXRACKARM2 Fixed Rack Brackets ASR1550LCDBEZ Bezel for Intel ® Mini Control Panel Bezel for Intel ® Local Control Panel AXXRAKSAS2 RAID Activation Key AXXMINIDIMM512 RAID Mini DIMM ASR1550MINBEZ AXXSATADVDROM Slimline DVD-ROM/CD-ROM Drive A complete list of accessories and spares can be found at: http://support.intel.com/support/motherboards/server/s5520ur/ Intel ® Remote Management Module 3 AXXRMM3 ASR1625PS 650-W Power Supply ASR1625LCP Intel ® Local Control Panel Module ASR1625FP Standard Control Panel Module Inifiniband* I/O Expansion Module SAS I/O Expansion Module Dual Gigabit I/O Expansion Module AXXGBIOMOD AXXSASIOMOD Quad-Port Gigabit I/O Expansion Module 10 Gigabit I/O Expansion Module AXX10GBIOMOD AXXIBIOMOD AXX4GBIOMOD2 15 Install Second Power Supply (optional) Use the 'finger hole' to remove the filler panel. To remove a power supply module, push the green latch in the direction shown while pulling it out of the system by the handle. Insert the power supply module into the power supply cage and push hard until it clicks into place. A B Handle PS Latch 23 Finishing Up Before installing your operating system, you must finish your system installation, make I/O connections, and plug in AC power. AC Power CAUTION: This unit must be operated with the TOP COVER installed to ensure proper cooling. Video 2. Install the server into the rack using the instructions provided with the rack mounting kit. 1. Replace the system cover. I/O Exp. Module USB Intel ® RMM3 Module Serial Port A Network NIC1-2 3. Connect your USB keyboard/mouse, video and other I/O cables/devices as shown. Then connect the AC power cord. Intel® Server Board S5520UR Component Layout See your Intel ® Server System SR1625UR Service Guide for expanded component and connection information. Diag. LEDs USB 8, 9 USB 2, 5 Video ID LED Serial A CPU 1 I/O Exp. Module Conn. 1 I/O Exp. Module Conn. 2 SGPIO SATA Key LCP/AUX IPMB BMC Force Update Front USB SSD USB Power Supply Signal Conn. Serial B SATA 5 SATA 0 SATA 1 SATA 2 SATA 3 SATA 4 CPU 1 Fan Mem 1 Fan Status LED CPU 2 Fan Mem 2 Fan CPU Power Front Panel CPU 2 Bridge Board Conn. Sys 1 Fan Sys 2 Fan NIC1 NIC2 DIMM A2 DIMM C1 DIMM A1 DIMM B2 DIMM B1 DIMM C2 Main Power Fan Board DIMM Status LEDs Battery DIMM F1 DIMM D2 DIMM F2 DIMM E1 DIMM E2 DIMM D1 PCIe* Riser RMM3 Conn. DIMM Status LEDs BIOS Recover Password Clear BIOS Default Serial Port Config. Document/Tool Available Documents Technical Product Specification Spares, Parts List, and Configuration Guide Server Configurator Tool Software and Drivers Content In-depth technical information Supported accessories and spares list Tested peripherals and operating systems list Tested memory list Supported processors list Up-to-date firmware, driver, and utility information A link to the above documents, Server Configurator Tool, and the Software and Drivers web page can be found at: http://support.intel.com/support/motherboards/server/s5520ur/

Upload: buidat

Post on 28-Jul-2018

234 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: E52699-004 SR1625UR QSUG back - intel.com€¦ · If using on-board RAID, you must activate RAID in the BIOS setup. ... DIMM A2 DIMM A1 DIMM B2 DIMM B1 DIMM C2 DIMM C1 Main Power

Side

2

16 Install Standard Control Panel or Intel® Local Control Panel (optional)

Slide the control panel fully into the server system until it clicks into place.

C

Feed the control panel cables into the chassis opening.

B

Connect the USB and data cables to the replacement control panel as shown.

A

Connect the two cables to the USB and control panel connectors on the back side of the backplane as shown.

D

Install the mini control panel filler panel.

E

Remove the filler on the right as shown.

B

Press the latch at the back of the mini control panel and push the control panel forward to release it from the chassis.

A

Slide the mini control panel out through the front of the server system.

C

Remove the Mini Control Panel Install the Standard or Intel® Local Control Panel

Latch

Mini Control

Panel

LocalControl Panel

A

C

B

Filler Panel

LocalControl Panel

Filler Panel

B

A

Backplane

CD

E

17 Install Processor Air Duct

Use care to avoid pinching system cables.

ProcessorAir Duct

18 Install Add-in Card(optional)

A Remove filler panel from the add-in card slot.

BInsert add-in card until it seats in riser connector.CSecure the add-in card with screw as shown. D

Remove the screw as shown.

CAUTION:Observe normal ESD precautions when installing the add-in card.

Riser Connector

REMOVE Filler Panel

D

B

A

C

19 Install Add-in Card Riser Assembly

Riser CardEdge ConnectorPress down uniformly until the

two hooks on the rear of the PCI riser assembly engage the chassis back panel slots.The riser card will seat into the matching riser socket on the server board.

B

PCI RiserSocket

ChassisSlots (2)

Hooks (2)

ProcessorAir Duct

Air DuctSlot

Position riser card edge connector over the server board riser socket and align the two hooks in the riser with the slots at the back of the chassis.

A

Note that the riser assembly card edge installs in the slot in the processor air duct.

12 Install Passive System (Product Code: SR1625UR) Components...for an Active System, go to Step 11

Connect SATA cables from passive midplane board to server board as shown.Route cables under the retentiontab and alongside the powersupply as shown to allowclearance for a full-height PCI add-in card.

A

B

PassiveMidplane

Power DistributionBoard Cover

A

B

0321

4 5

Power Supply

Cable Retention

Tab

CAUTION: It is critical thatyou connect the SATA datacables correctly from theSATA midplane to yourserver board or RAID Controller card. Failure todo so may result in data loss.

4 5 6 7

1 2 3Passive Midplane

SATA Connectors

A 0

ServerBoard

14 Install Optical Device

Insert the optical drive into chassis opening and push all the way until it stops.

B

Install the plastic guideonto the back of the driveand attach with two screws as shown.

A

A

IMPORTANT NOTE: If you do not install a device at this location, install the optical device bay filler panel shown below.This is required to maintain proper system cooling.

B

20Install Rack Handles

21Install Top Cover

Note: Security screwre-installation is optional.

APlace cover as shown, slide forwardto engage recessed edge atfront of cover. Make surelatch is locked.

A

RecessedEdge

11 Install Active System (Product Code: SR1625URSAS) Components ... for a Passive System, go to Step 12Remove Power Distribution Board Cover (optional)

This step is only necessary if you are installing the optional RAID Battery Backup Unit (BBU).

Power

Distribution

Board Cover

Check RAID BBU Battery Connection Install RAID Battery Backup Unit (optional) Install RAID DIMM and RAID Activation Key (optional) Install Power Distribution Board (PDB) Cover

The RAID BBU has an internal battery powercable. Open the BBU case lid as shown.

A

If the battery powercable is not connected, connect the cable now.

Close and latch the BBU case lid.

B

A

B

The RAID BBU has two hooks on the underside. Align these hooks with the matching chassistabs, then slide toward the power supply to lock into place.

A

Connect the power cablebetween the BBU and the midplane board as shown.

B

Midplane RAIDBBU Connector

ChassisTab(2)

PowerSupply

BatteryBackupUnit

A

B

ChassisStandoff

PDBPower

DistributionBoard

Power

Distribution

Board Cover

A B

Insert the Intel® RAID Activation Key into the midplane board socket as shown. Make sure the key snaps into the socket.

A

Open RAID mini DIMM socket levers and insert connectoredge of mini DIMM into socket until levers close and snap into place.

B

Backplane Board not shown for clarity

Intel® RAID Activation

Key Socket

RAID Mini DIMMSocket

RAID Mini DIMM

RAIDKey

Open Levers

B

A

MidplaneBoard

A

B

Install power distribution board cover by aligning with the power distribution board and the matching thumbscrew hole.

Note that the thumbscrew attaches to a chassis standoff underneath the PDB. If the PDB is not installed correctly, the thumbscrew will not align with the standoff.

Power

Distribution

Board Cover

Note: Standard and Intel ® LocalControl Panel install the same.

22Install Bezel (optional)

Mini Control Panel Bezel

Select the bezel that matches your control panel and install as shown.

Intel® Local Control Panel Bezel

Standard Control Panel Bezel

Front Panel Controls and IndicatorsIntel® Local Control Panel Standard Control Panel

A NIC2 Activity LEDB. NIC1 Activity LEDC. Power/Sleep ButtonD. Power/Sleep LEDE. Hard Drive Activity LEDF. Status LED

G. System ID LEDH. System ID ButtonI. Reset ButtonJ. USB 1.1 PortK. NMI (recessed) ButtonL. Video

A USB 1.1 PortB. LCD DisplayC. Menu Control Button - UpD. Menu Control Button - DownE. Menu Control Button - LeftF. Menu Control Button - EnterG. ID LED

H. Power/Sleep LEDI. Power/Sleep ButtonJ. System Status LEDK. NIC 2 Activity LEDL. NIC 1 Activity LEDM. HDD Activity LEDN. Reset ButtonO. USB 1.1 Port

BA DC

G EF

Mini Control Panel

A USB 1.1 PortB. System ID LEDC. System Status LEDD. Power/Sleep LEDE. Power/Sleep ButtonF. NMI ButtonG. System ID Button

O M L K J HIN G

CDEF

BA

J IL K

BA F G HEDC

24 Software • BIOS, Drivers, and Operating System Installation

C. Install your Operating System: Use the instructions provided with the RAID controller and with the operating system.

D. Install Operating System Drivers: With the operating system running, insert the Intel® Server Deployment Toolkit CD. If using a Microsoft Windows* operating system, the Express Installer will autorun and allow you to select the appropriate drivers to install. On other operating systems, browse the CD folders to locate and install the driver files.

E. Install Intel® System Management Software (optional): Download the latest version of the Intel® System Management Software from http://www.intel.com/go/servermanagement and use the instructions provided at that link to install the software.

A. Update the System Software: 1. Boot from the Intel® Server Deployment Toolkit CD.2. Use the Wizard to access the latest versions on the Internet and update the BIOS, firmware, FRUSDRs, and Intel® RMM3. Note: You can also use downloaded files on a USB key.

B. Configure your RAID Controller: If using a RAID card, use the instructions provided with the RAID controller. If using on-board RAID, you must activate RAID in the BIOS setup. See the Intel® Server Board S5520UR Technical Product Specification for more information.

Note: Rack handles are required to install the bezel. For detailed instructions, see the Service Guide.

Install processorair duct as shown making sure the front edge of the duct aligns correctly with the notches on the fan module.

USBCable

DataCable

Note: To install hard drives in drive locations 6 and 7, you must remove the filler panel.

13 Install Hard Drives/Carriers

Remove the drive carrier by pressing in on the green latch, pulling out on the black lever and sliding the drive carrier out.

Repeat these steps for each installed hard drive

Note: Carrier lever must be held in the FULLY OPEN position to install into the chassis. Slide carrier into chassis until it clicks, then close the lever.

A Remove the plastic air baffle and save for future use.

B

Install the hard disk drive as shown.

C

Install hard disk drive assembly into chassis opening.

D

CAUTION: If you install less than eight drives or devices, empty drive bays must be occupied by carriers with baffles or with a filler panel provided for drive locations 6 and 7 to maintain proper system cooling.

Drive 0 Primary

Hard Drive Numbering Diagram31

2

7

64 50

Attach withfour screws.

C

Remove only when

installing hard drive device.

Keep for future use

B

Press in on the green latch to open lever.

A

D

Note: To install hard drivesin drive locations 6 and 7, remove the filler panel.

AXXHERAIL2Cable Management ArmTool-less Rail Kit

AXXBASRAIL13Basic Slide Rail Kit

ASR1550BEZBezel for Standard Control Panel

Optional Accessories and Order Codes

AXXBRACKETS

AXXRACKARM2

Fixed Rack Brackets

ASR1550LCDBEZBezel for Intel® Mini Control PanelBezel for Intel® Local Control Panel

AXXRAKSAS2RAID Activation KeyAXXMINIDIMM512RAID Mini DIMM

ASR1550MINBEZ

AXXSATADVDROMSlimline DVD-ROM/CD-ROM Drive

A complete list of accessories and spares can be found at: http://support.intel.com/support/motherboards/server/s5520ur/Intel® Remote Management Module 3 AXXRMM3

ASR1625PS650-W Power Supply

ASR1625LCPIntel® Local Control Panel ModuleASR1625FPStandard Control Panel Module

Inifiniband* I/O Expansion ModuleSAS I/O Expansion ModuleDual Gigabit I/O Expansion Module AXXGBIOMOD

AXXSASIOMOD

Quad-Port Gigabit I/O Expansion Module10 Gigabit I/O Expansion Module AXX10GBIOMOD

AXXIBIOMOD

AXX4GBIOMOD2

15 Install Second Power Supply(optional)

Use the 'finger hole' to remove the filler panel. To remove a power supply

module, push the green latchin the direction shown while pulling it out of the system by the handle.

Insert the power supply module into the power supply cage and push hard until it clicks into place.

A

B

HandlePS Latch

23Finishing Up

Before installing your operating system, you must finish your system installation, make I/O connections, and plug in AC power.

AC Power

CAUTION: This unit must be operated with the TOP COVER installed to ensure proper cooling.

Video

2. Install the server into the rack using the instructions provided with the rack mounting kit.

1. Replace the system cover.

I/O Exp. ModuleUSB Intel ® RMM3 ModuleSerial

Port A

Network

NIC1-2

3. Connect your USB keyboard/mouse, video and other I/O cables/devices as shown. Then connect the AC power cord.

Intel® Server Board S5520URComponent LayoutSee your Intel® Server System SR1625UR Service Guide for expanded component and connection information.

Diag.LEDs

USB8, 9

USB2, 5 Video ID LED

Serial A

CPU 1

I/O Exp.Module Conn. 1

I/O Exp.Module Conn. 2

SGPIOSATA Key

LCP/AUX IPMBBMC Force

Update

Front USBSSDUSB Power

SupplySignalConn.

Serial B

SATA 5

SATA 0

SATA 1

SATA 2

SATA 3

SATA 4

CPU 1 Fan

Mem 1 Fan

StatusLED

CPU 2Fan

Mem 2Fan

CPUPower

FrontPanel

CPU 2

Brid

ge B

oard

Con

n.

Sys 1Fan

Sys 2Fan

NIC

1

NIC

2

DIM

M A

2

DIM

M C

1

DIM

M A

1D

IMM

B2

DIM

M B

1D

IMM

C2

Main Power

Fan Board

DIMM Status LEDs

Battery

DIM

M F

1

DIM

M D

2

DIM

M F

2D

IMM

E1

DIM

M E

2D

IMM

D1

PCIe

* Ris

er

RM

M3

Con

n.

DIMMStatusLEDs

BIOSRecover

PasswordClear

BIOSDefault

Serial PortConfig.

Docu

men

t/Too

lA

vaila

ble

Do

cum

ents

Tech

nica

l Pro

duct

Spec

ifica

tion

Spar

es, P

arts

List,

and

Conf

igur

ation

Gui

de

Serv

er C

onfig

urato

r Too

l

Softw

are a

nd D

river

s

Cont

ent

In-d

epth

tech

nica

l inf

orm

ation

Supp

orted

acce

ssor

ies an

d sp

ares

list

Teste

d pe

riphe

rals

and

oper

ating

syste

ms l

istTe

sted

mem

ory l

istSu

ppor

ted p

roce

ssor

s list

Up-to

-date

firm

ware

, driv

er, an

d ut

ility

info

rmati

on

A lin

k to

the a

bove

doc

umen

ts, S

erve

r Con

figur

ator T

ool,

and

the S

oftw

are a

nd D

river

s we

b pa

ge ca

n be

foun

d at:

http

://su

ppor

t.int

el.co

m/s

uppo

rt/m

othe

rboa

rds/

serv

er/s

5520

ur/