e install raid battery backup unit a hard disk c drive y a ...€¦ · if using on-board raid, you...

1
Side 2 15 Install Second Power Supply Module (optional) Use the 'finger hole' to remove the filler panel. To remove a power supply module, push the green latch in the direction shown while pulling out of the system by the handle. Insert the power supply module into the power supply cage and push all the way until it clicks into place. A B Handle PS Latch Finger Hole 14 Tape Drive 2.5 Inch Fixed Drive Install Additional Drives (optional) See the Service Guide for instructions on installing an optional tape drive, or two additional 2.5 inch fixed drives. 18 Install Add-in Card(s) A B Open rear retention clip by pushing blue slide upward and rotating clip fully open. Open front retention clip by pushing the blue latch in the direction shown and rotating clip 90 degrees outward. C Remove filler panel from the selected add-in card slot. D Insert add-in card until it seats in the riser connector. E Close both retention clips. Note: Make sure that all empty add-in card slots have filler panels installed. Full-height Side of PCI Riser Shown Note: Add-in card install sequence for low-profile add-in cards on opposite side of PCI riser is the same. REMOVE Filler Panel B A C D CAUTION: Observe normal ESD precautions when installing add-in cards. A complete list of accessories and spares can be found at: http://support.intel.com/support/motherboards/server/s5520ur/ Front Panel Controls and Indicators Intel® Local Control Panel Standard Control Panel O M L K J H I N G C D E F B A J I K B A F G H E D C A NIC2 Activity LED B. NIC1 Activity LED C. Power/Sleep Button D. Power/Sleep LED E. Hard Drive Activity LED F. Status LED G. System ID LED H. System ID Button I. Reset Button J. USB 1.1 Port K. NMI (recessed) Button L. Video A USB 1.1 Port B. LCD Display C. Menu Control Button - Up D. Menu Control Button - Down E. Menu Control Button - Left F. Menu Control Button - Enter G. ID LED H. Power/Sleep LED I. Power/Sleep Button J. System Status LED K. NIC 2 Activity LED L. NIC 1 Activity LED M. HDD Activity LED N. Reset Button O. USB 1.1 Port 11 Check RAID BBU Battery Connection Install RAID Battery Backup Unit (BBU) (optional) Install Intel® RAID Activation Key and RAID Mini DIMM (optional) Insert the Intel ® RAID Activation Key into the midplane board socket as shown. Make sure the key snaps into the socket. A Open RAID mini DIMM socket levers and insert connector edge of mini DIMM into socket until levers close and snap into place. B The RAID BBU has two hooks on the underside. Align these hooks with the matching chassis tabs, then slide toward the power supply to lock into place. A Connect the power cable between the BBU and the midplane board as shown. Note: Backplane not shown for clarity. B A B Midplane RAID BBU Connector Chassis Tab(2) Power Supply Battery Backup Unit The RAID BBU has an internal battery power cable. Open the BBU case lid as shown. A If the battery power cable is not connected, connect the cable now. Close and latch the BBU case lid. B A B Backplane Board not shown for clarity Intel ® RAID Activation Key Socket RAID Mini DIMM Socket RAID Mini DIMM RAID Key Open Levers B A Midplane Board 19 Install PCI Add-in Card Riser Assembly Position the riser card edge connector over the server board riser socket and align the three hooks in the riser with the slots at the back of the chassis. To install the riser assembly: A Press down uniformly until the three hooks on the rear of the PCI riser assembly engage the chassis back panel slots. The riser card will seat into the matching socket on the server board. B Note: The PCI riser assembly includes an intrusion switch that engages the system cover. Do not use the intrusion header located on the server board. Intrusion Switch Chassis Back Panel Hook (3) Riser Socket PCI Riser Assembly B Slot (3) Riser Card Connector Server Board Riser Socket Hooks (3) A 13 Install Optical Device Insert the optical drive into chassis opening and push all the way until it stops. B Install the plastic guide onto the back of the drive and attach with two screws as shown. A A IMPORTANT NOTE: If you do not install a device at this location, install the optical device bay filler panel shown below. This is required to maintain proper system cooling. B Optical Drive 22 Install Bezel (optional) Select the bezel that matches your control panel and install as shown. Standard Control Panel Bezel Intel® Local Control Panel Bezel Hard Disk Drive Install Active System Components...for a Passive System, skip this step 23 Install Top Cover Place top cover onto the chassis and slide forward to engage recessed edge at front of cover. A Install security screw. Note that security screw re-installation is optional. B A B 21 Install Rack Handles Note: Rack handles are required to install the bezel. For detailed instructions, see the Service Guide. F Document Type Available Documents Technical Product Specification Spares, Parts List, and Configuration Guide Software and Drivers Content In-depth technical information Supported accessories and spares list Tested peripherals and operating systems list Tested memory list Supported processors list Up-to-date firmware, driver, and utility information Server Configurator Tool These documents can be found at: http://support.intel.com/support/motherboards/server/s5520ur/ 17 Replacing the Riser Card (optional) A B Push back on the blue riser lever. While holding the lever back, slide the card firmly in the direction shown to disengage the riser pins and remove the riser card. Remove the riser card C D Push back and hold the blue lever in that position. Place the riser card onto the retention pins. E Slide the riser card in the direction shown to lock it into place. Release the blue riser lever. Install the replacement riser card Riser Card A Blue Riser Lever Riser Retention Pin C D E B 16 Install Processor Air Duct Use care to avoid pinching system cables. Processor Air Duct Install processor air duct as shown making sure the front edge of the duct contacts the fan module. 12 Install Hard Drives/Carriers Remove the drive carrier by pressing the green latch to unlock. Repeat these steps for each installed hard drive Note: Carrier lever must be held in the FULLY OPEN position to install into the chassis. Slide carrier into chassis until it clicks, then close the lever. A Pull out on the black lever and slide the carrier out. B Remove the plastic air baffle and save for future use. C Install the hard disk drive as shown. D Install hard disk drive assembly into the chassis opening. E CAUTION: If you install less than eight drives or devices, empty drive bays must be occupied by carriers with baffles or with a filler panel provided for drive locations 6 and 7 to maintain proper system cooling. Drive 0 Primary Hard Drive Numbering Diagram Attach with four screws. D Remove only when installing hard drive device. Keep for future use C B 3 1 2 4 0 5 6 7 E A 20 Install Intel® Local Control Panel (optional) Press the blue locking lever and push forward to release the control panel from the chassis. B Disconnect the two cables from the back side of the backplane. A Slide control panel fully into chassis until the locking lever engages. F Feed local control panel cables into chassis opening. E Connect the USB and data cables to the local control panel as shown. D Connect the two cables to the USB and control panel connectors on the back side of the backplane as shown. G Remove Standard Control Panel Install Local Control Panel D B Locking Lever Local Control Panel E Slide the standard control panel and cables out of the chassis. C Backplane G F Locking Lever C USB Cable Data Cable 24 Finishing Up Before installing your operating system, you must finish your system installation, make I/O connections, and plug in AC power. AC Power CAUTION: This unit must be operated with the TOP COVER installed to ensure proper cooling. Video 1. Make sure the system top cover is installed. I/O Module Serial Port A Serial Port B Network NIC1-2 USB 0-3 Video Intel ® RMM3 NIC Module 2. Install the server into the rack using the instructions provided with the rack mounting kit. 3. Connect your USB keyboard/mouse, video and other I/O cables/devices as shown. Then connect the AC power cord(s). 25 Software BIOS, Drivers, and Operating System Installation B. Configure your RAID Controller: If using a RAID card, use the instructions provided with the RAID controller. If using on-board RAID, you must activate RAID in the BIOS setup. See the Intel ® Server Board S5520UR Technical Product Specification for more information. C. Install your Operating System: Use the instructions provided with the RAID controller and with the operating system. D. Install Operating System Drivers: With the operating system running, insert the Intel ® Server Deployment Toolkit CD. If using a Microsoft Windows* operating system, the Express Installer will autorun and allow you to select the appropriate drivers to install. On other operating systems, browse the CD folders to locate and install the driver files. A. Update the System Software: 1. Boot from the Intel ® Server Deployment Toolkit CD. 2. Use the Wizard to access the latest versions on the Internet and update the BIOS, firmware, FRUSDRs, and Intel ® RMM3. Note: You may also used downloaded files on a USB key. E. Install Intel® System Management Software (optional): Download the latest version of the Intel ® System Management Software from http://www.intel.com/go/servermanagement and use the instructions provided at that link to install the software. Intel® Server Board S5520UR Component Layout See your Intel ® Server System SR2600UR/ SR2625UR Service Guide for expanded component and connection information. Diag. LEDs USB 8, 9 USB 2, 5 Video ID LED Serial A CPU 1 I/O Exp. Module Conn. 1 I/O Exp. Module Conn. 2 SGPIO SATA Key LCP/AUX IPMB BMC Force Update Front USB SSD USB Power Supply Signal Conn. Serial B SATA 5 SATA 0 SATA 1 SATA 2 SATA 3 SATA 4 CPU 2 Fan Mem 2 Fan CPU Power Front Panel CPU 2 Bridge Board Conn. Sys 1 Fan Sys 2 Fan NIC1 NIC2 DIMM A2 DIMM C1 DIMM A1 DIMM B2 DIMM B1 DIMM C2 Main Power Fan Board DIMM Status LEDs Battery DIMM F1 DIMM D2 DIMM F2 DIMM E1 DIMM E2 DIMM D1 PCIe* Riser RMM3 Conn. DIMM Status LEDs CPU 1 Fan Mem 1 Fan Status LED BIOS Recover Password Clear BIOS Default Serial Port Config. AXXHERAIL2 Cable Management Arm Tool-less Rail Kit AXXBASRAIL13 Basic Slide Rail Kit ADRBEZBLACK Bezel for Standard Control Panel Optional Accessories and Order Codes AXXBRACKETS AXXRACKARM2 Fixed Rack Brackets ADRLCDBEZEL Intel ® Remote Management Module 3 Bezel for Intel ® Local Control Panel AXXRMM3 AXXSATADVDROM Slimline DVD-ROM/CD-ROM Drive ASR2600FIXDRV Fixed 2.5 inch Drive Mounting Kit ASR2500SATAPE SAS/SATA Tape Drive Mounting Kit AXXLCPRACK2 Intel ® Local Control Panel Module AXX750WPS 750-W Power Supply Infiniband* I/O Expansion Module AXXGBIOMOD Dual Gigabit I/O Expansion Module AXXSASIOMOD AXX4GBIOMOD2 AXX10GBIOMOD SAS I/O Expansion Module Quad-Port Gigabit I/O Expansion Module 10 Gigabit I/O Expansion Module AXXRAKSAS2 RAID Mini DIMM RAID Activation Key AXXMINIDIMM512 AXXIBIOMOD

Upload: dotuong

Post on 28-Jul-2018

230 views

Category:

Documents


0 download

TRANSCRIPT

Side

2

15 Install Second Power Supply Module (optional)

Use the 'finger hole'to remove the filler panel.

To remove a power supply module, push the green latch in the direction shown while pulling out of the system by the handle.

Insert the power supply module into the power supply cage and push all theway until it clicks into place.

A

B

Handle PS Latch

FingerHole

14

Tape Drive

2.5 Inch

Fixed Drive

Install AdditionalDrives (optional)

See the Service Guide for instructions on installing anoptional tape drive, or two additional 2.5 inch fixed drives.

18 Install Add-in Card(s)

A

B

Open rear retention clip by pushing blue slide upward and rotating clip fully open.Open front retention clip by pushing the blue latch in the direction shown and rotating clip 90 degrees outward.

C Remove filler panel from the selected add-in card slot.

D Insert add-in card until it seats in theriser connector.

E Close both retention clips. Note: Make sure that all empty add-in card slots have filler panels installed.

• Full-height Side of PCI Riser Shown

Note: Add-in card install sequence for low-profile add-in cards on opposite side of PCI riser is the same.

REMOVE Filler Panel

B

A

CD

CAUTION: Observe normal ESD precautions when installing add-in cards.

A complete list of accessories and spares can be found at: http://support.intel.com/support/motherboards/server/s5520ur/

Front Panel Controls and IndicatorsIntel® Local Control Panel Standard Control Panel

O M L K J HIN G

CDEF

BA

J IK

BA F G HEDC

A NIC2 Activity LEDB. NIC1 Activity LEDC. Power/Sleep ButtonD. Power/Sleep LED

E. Hard Drive Activity LEDF. Status LEDG. System ID LED

H. System ID ButtonI. Reset ButtonJ. USB 1.1 PortK. NMI (recessed) ButtonL. Video

A USB 1.1 PortB. LCD DisplayC. Menu Control Button - UpD. Menu Control Button - Down

E. Menu Control Button - Left F. Menu Control Button - Enter G. ID LED H. Power/Sleep LED

I. Power/Sleep ButtonJ. System Status LEDK. NIC 2 Activity LEDL. NIC 1 Activity LEDM. HDD Activity LEDN. Reset ButtonO. USB 1.1 Port

11Check RAID BBUBattery Connection

Install RAID Battery Backup Unit(BBU) (optional)

Install Intel® RAID Activation Key and RAID Mini DIMM (optional)

Insert the Intel® RAID Activation Key into the midplane board socket as shown. Make sure the key snaps into the socket.

A

Open RAID mini DIMM socket levers and insert connectoredge of mini DIMM into socket until levers close and snap into place.

B

The RAID BBU has two hooks onthe underside. Align these hookswith the matching chassis tabs, then slide toward the power supplyto lock into place.

A

Connect the power cable between the BBU and the midplane board as shown.

Note: Backplane notshown for clarity.

BA

B

Midplane RAIDBBU Connector

ChassisTab(2)

PowerSupply

BatteryBackupUnitThe RAID BBU has an internalbattery power cable. Open theBBU case lid as shown.

A

If the battery power cable is notconnected, connect the cable now.Close and latch the BBU case lid.

B

A

B

Backplane Board not shown for clarity

Intel® RAID Activation

Key Socket

RAID Mini DIMMSocket

RAID Mini DIMM

RAIDKey

Open Levers

B

A

MidplaneBoard

19 Install PCI Add-in Card Riser Assembly

Position the riser card edge connector over the server board riser socket and align the three hooksin the riser with the slots at the back of the chassis.

To install the riser assembly:A

Press down uniformly until the three hooks on the rear of the PCI riser assembly engage the chassis back panel slots.

The riser card will seat into the matching socket on the server board.

B

Note: The PCI riser assemblyincludes an intrusion switch thatengages the system cover.Do not use the intrusion header located on the server board.

IntrusionSwitch

Chassis Back Panel

Hook (3)

RiserSocket

PCIRiserAssembly

B

Slot (3)

Riser CardConnector

Server BoardRiser Socket

Hooks (3)

A

13 Install Optical Device

Insert the optical drive into chassis opening and pushall the way until it stops.

B

Install the plastic guideonto the back of the drive and attach with two screws as shown.

AA

IMPORTANT NOTE: If you do not install a device at this location, install the optical device bay filler panel shown below. This is required to maintain proper system cooling.

BOpticalDrive

22 Install Bezel (optional)

Select the bezel that matches your control panel and install as shown.

Standard Control Panel Bezel

Intel® Local Control Panel Bezel

HardDiskDrive

Install Active System Components...for a Passive System, skip this step

23 Install Top Cover

Place top cover onto the chassis andslide forward to engage recessed edge at front of cover.

A

Install security screw. Note that security screw re-installation is optional.

B

A

B

21 Install RackHandles

Note: Rack handles are required to install the bezel.For detailed instructions, see the Service Guide.

F

Docu

men

t Typ

eA

vaila

ble

Do

cum

ents

Tech

nica

l Pro

duct

Spec

ifica

tion

Spar

es, P

arts

List,

and

Conf

igur

ation

Gui

de

Softw

are a

nd D

river

s

Cont

ent

In-d

epth

tech

nica

l inf

orm

ation

Supp

orted

acce

ssor

ies an

d sp

ares

list

Teste

d pe

riphe

rals

and

oper

ating

syste

ms l

istTe

sted

mem

ory l

istSu

ppor

ted p

roce

ssor

s list

Up-to

-date

firm

ware

, driv

er, an

d ut

ility

info

rmati

on

Serv

er C

onfig

urato

r Too

l

Thes

e doc

umen

ts ca

n be

foun

d at:

http

://su

ppor

t.int

el.co

m/s

uppo

rt/m

othe

rboa

rds/

serv

er/s

5520

ur/

17 Replacing the Riser Card (optional)

AB

Push back on the blue riser lever.

While holding the lever back, slide thecard firmly in the direction shown todisengage the riser pins and removethe riser card.

Remove the riser card

C

D

Push back and hold the blue lever in that position.Place the riser card onto the retention pins.

E Slide the riser card in thedirection shown to lockit into place.Release the blue riserlever.

Install the replacement riser card

Riser Card

ABlue Riser Lever

Riser Retention Pin

C

DE

B

16 Install Processor Air Duct

Use care to avoid pinching system cables.

ProcessorAir Duct

Install processorair duct as shown making sure the front edge of the duct contacts the fan module.

12 Install Hard Drives/CarriersRemove the drive carrier by pressing the green latch to unlock.

Repeat these steps for each installed hard drive

Note: Carrier lever must be held in the FULLY OPEN position to install into the chassis. Slide carrier into chassis until it clicks, then close the lever.

A

Pull out on the black lever and slide thecarrier out.

B

Remove the plastic air baffle and save for future use.

C

Install the hard disk drive as shown.

D

Install hard disk drive assembly into the chassis opening.

E

CAUTION: If you install less than eight drives or devices, empty drive bays must be occupied by carriers with baffles or witha filler panel provided for drive locations 6 and 7 to maintain proper system cooling. Drive 0 Primary

Hard Drive Numbering Diagram

Attach withfour screws.

D

Remove only when

installing hard drive device.

Keep for future use

C

B31

2 40

5

6

7

E

A

20 Install Intel® Local Control Panel (optional)

Press the blue locking lever and push forward to release the control panel from the chassis.

B

Disconnect the two cables from the back side of the backplane.

A

Slide control panel fully into chassis until the locking lever engages.

FFeed local control panel cables into chassis opening.EConnect the USB and data cables to the local control panel as shown.D

Connect the two cables to the USB and control panel connectors on the back side of the backplane as shown.

G

Remove Standard Control Panel Install Local Control Panel D

BLockingLever

LocalControl Panel

E

Slide the standard control panel and cables out of the chassis.

C

Backplane

GF

LockingLever

C

USBCable

DataCable

24 Finishing UpBefore installing your operating system, you must finish your systeminstallation, make I/O connections, and plug in AC power.

AC Power

CAUTION: This unit must be operated with the TOP COVER installed to ensure proper cooling.

Video

1. Make sure the system top cover is installed.

I/O Module

SerialPort A

SerialPort B

Network

NIC1-2

USB 0-3

Video

Intel® RMM3 NIC Module

2. Install the server into the rack using the instructions provided with the rack mounting kit.3. Connect your USB keyboard/mouse, video and other I/O cables/devices as shown. Then connect the AC power cord(s).

25Software • BIOS, Drivers, and Operating System Installation

B. Configure your RAID Controller: If using a RAID card, use the instructions provided with the RAID controller. If using on-board RAID, you must activate RAID in the BIOS setup. Seethe Intel® Server Board S5520UR Technical Product Specification for more information.

C. Install your Operating System: Use the instructions provided with the RAID controller and with the operating system.

D. Install Operating System Drivers: With the operating system running, insert the Intel® Server Deployment Toolkit CD. If using a Microsoft Windows* operating system, the Express Installer will autorun and allow you to select the appropriate drivers to install. On other operating systems, browse the CD folders to locate and install the driver files.

A. Update the System Software: 1. Boot from the Intel® Server Deployment Toolkit CD.2. Use the Wizard to access the latest versions on the Internet and update the BIOS, firmware,FRUSDRs, and Intel® RMM3. Note: You may also used downloaded files on a USB key.

E. Install Intel® System Management Software (optional): Download the latest version of the Intel® System Management Software from http://www.intel.com/go/servermanagement and use the instructions provided at that link to install the software.

Intel® Server Board S5520UR Component Layout

See your Intel® Server SystemSR2600UR/SR2625UR Service Guide for expanded component and connection information.

Diag.LEDs

USB8, 9

USB2, 5 Video ID LED

Serial A

CPU 1

I/O Exp.Module Conn. 1

I/O Exp.Module Conn. 2

SGPIOSATA Key

LCP/AUX IPMBBMC Force

Update

Front USBSSDUSB Power

SupplySignalConn.

Serial B

SATA 5

SATA 0

SATA 1

SATA 2

SATA 3

SATA 4

CPU 2Fan

Mem 2Fan

CPUPower

FrontPanel

CPU 2

Brid

ge B

oard

Con

n.

Sys 1Fan

Sys 2Fan

NIC

1

NIC

2

DIM

M A

2

DIM

M C

1

DIM

M A

1D

IMM

B2

DIM

M B

1D

IMM

C2

Main Power

Fan Board

DIMM Status LEDs

Battery

DIM

M F

1

DIM

M D

2

DIM

M F

2D

IMM

E1

DIM

M E

2D

IMM

D1

PCIe

* Ris

er

RM

M3

Con

n.

DIMMStatusLEDs

CPU 1 Fan

Mem 1 Fan

StatusLED

BIOSRecover

PasswordClear

BIOSDefault

Serial PortConfig.

AXXHERAIL2Cable Management ArmTool-less Rail Kit

AXXBASRAIL13Basic Slide Rail Kit

ADRBEZBLACKBezel for Standard Control Panel

Optional Accessories and Order Codes

AXXBRACKETS

AXXRACKARM2

Fixed Rack Brackets

ADRLCDBEZEL

Intel® Remote Management Module 3

Bezel for Intel® Local Control Panel

AXXRMM3

AXXSATADVDROMSlimline DVD-ROM/CD-ROM Drive

ASR2600FIXDRVFixed 2.5 inch Drive Mounting KitASR2500SATAPESAS/SATA Tape Drive Mounting Kit

AXXLCPRACK2Intel® Local Control Panel Module

AXX750WPS750-W Power Supply

Infiniband* I/O Expansion ModuleAXXGBIOMODDual Gigabit I/O Expansion ModuleAXXSASIOMODAXX4GBIOMOD2AXX10GBIOMOD

SAS I/O Expansion ModuleQuad-Port Gigabit I/O Expansion Module10 Gigabit I/O Expansion Module

AXXRAKSAS2RAID Mini DIMMRAID Activation Key

AXXMINIDIMM512

AXXIBIOMOD