bioluminescence: luciferin-lucferase atp detection assay

27
Chemiluminescence, Bioluminescence, and the Luciferin- Luciferase ATP Detection Assay Ashley Long February 22, 2011 Bioanalytical Chemistry – Spring 2011

Upload: lecong

Post on 13-Jan-2017

243 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Bioluminescence: Luciferin-Lucferase ATP Detection Assay

Chemiluminescence, Bioluminescence, and

the Luciferin-Luciferase ATP Detection Assay

Ashley LongFebruary 22, 2011

Bioanalytical Chemistry – Spring 2011

Page 2: Bioluminescence: Luciferin-Lucferase ATP Detection Assay

Overview • Background on Chemiluminescence and

Bioluminescence• General overview of uses of

Bioluminescence in High-Throughput Screening (HTS)

• Introduction to the Luciferin-Luciferase ATP detection assay and its importance in HTS

Page 3: Bioluminescence: Luciferin-Lucferase ATP Detection Assay

The firefly

Image from: http://scienceline.org/2010/11/lighting-

the-way/

Page 4: Bioluminescence: Luciferin-Lucferase ATP Detection Assay

What is chemiluminescence?

• Occurs when an EXOTHERMIC CHEMICAL reaction releases energy to generate electromagnetic radiation which gives off light 1,2

• Types1:– Reactions with synthetic compounds (i.e. H2O2)

– Bioluminescent reactions – from a living organism– Electrochemiluminescent reactions – use electric current

Page 5: Bioluminescence: Luciferin-Lucferase ATP Detection Assay

More on ChemiluminescenceFluorescence Chemiluminescence

• See energy gain through chemical reaction

• Lower signal (intensity), but little to NO background = beter S/N

• Light must be absorbed by fluorophore to reach excited state

• Brighter, but MORE background

(Figure 1) Citation 2

Page 6: Bioluminescence: Luciferin-Lucferase ATP Detection Assay

What is bioluminescence?• A type of chemiluminescence that

occurs in living organisms • Enzyme catalyzed reactions– Enzymes: luciferases

• Firefly luciferase• Renilla luciferase (sea pansy)• Aequorin (jellyfish- Aequorea victoria)

– Substrates (photon-emitting): luciferins

Citation 2; Image taken fromhttp://www.biosynth.com/index.asp?

topic_id=119&g=19&m=264:

Page 7: Bioluminescence: Luciferin-Lucferase ATP Detection Assay

Firefly Bioluminescence• Light Intensity ~ Chemical Concentration – [Chemical] of interest can be ATP, luciferin, or

luciferase (hold all others constant)– Very large linear range

• Most common luciferase used in the development of High-Throughput Screening (HTS) Assays

Citation 2

Page 8: Bioluminescence: Luciferin-Lucferase ATP Detection Assay

Firefly Luciferase Catalyzed Rxn

(Figure 2) Citation 2

Yellow-green light λmax =

560 nm

Page 9: Bioluminescence: Luciferin-Lucferase ATP Detection Assay

How do you detect the signal? The GloMax® 20/20 Luminometer is designed to provide

ultra-high performance for bioluminescent and chemiluminescent assays. In addition to high performance, the GloMax® 20/20 blends user-friendly operation and a small footprint with flexible purchasing options. The result of this design is an instrument with superior performance that is easy to use, affordable, and can be customized to your lab’s needs.3

The GloMax®-96 Microplate Luminometer is a state-of-the-art microplate luminometer that meets the requirement for high sensitivity and broad dynamic range that is necessary for chemiluminescent and bioluminescent applications. With optional Single or Dual Auto Injectors, the GloMax®-96 is a versatile luminescence system capable of performing both flash and glow-type luminescent assays.3

Citation 3

Page 10: Bioluminescence: Luciferin-Lucferase ATP Detection Assay

How can this reaction be used in HTS?

(Figure 3) Citation 2

Page 11: Bioluminescence: Luciferin-Lucferase ATP Detection Assay

HTS: Luciferase Concentration

• Goal: investigate intracellular events by monitoring gene transcription

• May include internal control (dual-luciferase assay)• Simple and efficient (HTS)• Commonly used for GPCR and nuclear receptor

assays (Figure 3) Citation 2

Page 12: Bioluminescence: Luciferin-Lucferase ATP Detection Assay

HTS: Luciferin Concentration

• Luciferin is not naturally linked to physiology (vs. ATP)• Use a Pro-luciferin

– Enzyme of interest must convert this to luciferin link luminescent signal to enzyme of interest

(Figure 3) Citation 2

Page 13: Bioluminescence: Luciferin-Lucferase ATP Detection Assay

HTS: ATP Concentration

• Enzyme must be consistent! Often use “stabilized” luciferase enzymes for HTS

• Used in:– Cytotoxicity screens ATP concentrations ~ cell viability – Kinase activity screens all kinases consume ATP in phosphorylation rxn– Real-time detection of ATPase activity4

– ~ 100X more sensitive and significantly faster than some dye assays used to look at cell metabolism

(Figure 3) Citation 2

Page 14: Bioluminescence: Luciferin-Lucferase ATP Detection Assay

Examples of HTS assays • Luciferase Enzymatic Activity

monitoring assays2

– Sensitive & broad detection range

• Protein- Protein interaction assays5,6

– BRET – Bioluminescence resonance energy transfer

– PCA – Protein fragment complementation assay

• Real-time bioluminescence to analyze inhibitors of polymerases (DNA & RNA)7

(Figure 2) Citation 6

Page 15: Bioluminescence: Luciferin-Lucferase ATP Detection Assay

Examples of HTS assays • BL/CL recombinant whole-

cell biosensors– Genetically engineered cells– Create a luminescent signal

~ to a specific analyte (analyte should be regulating gene expression)

– Used for monitoring:• Stress, oxidants, metals,

xenobiotics, receptor activating molecules, etc.

(Figure 5), Citation 6

Page 16: Bioluminescence: Luciferin-Lucferase ATP Detection Assay

ATP Assay Kit - Demonstration• ATP Determination Kit

– Molecular Probes (Invitrogen )– Bioluminescence assay – Quantitative determination of ATP concentrations– Components:

• Recombinant firefly luciferase (enzyme)• D-luciferin (substrate)

Luciferin + ATP + O2

oxyluciferin + AMP + pyrophosphate + CO2 + light

(Mg2+) (luciferase)

Citation 8

Page 17: Bioluminescence: Luciferin-Lucferase ATP Detection Assay

ATP Assay – Standards

Page 18: Bioluminescence: Luciferin-Lucferase ATP Detection Assay

ATP Determination Kit• Advantages:

– Very sensitive – Detect down to ~ 0.1 picomoles of ATP (must create a

standard curve within the desired range) – Readily available & affordable

• Uses:– Versatile (can be used to look at ATP production in different

enzymatic reactions) – NADPH, ATPase– Detect contamination in a range of samples (milk, blood,

sludge, etc.)– Many others!

Citation 8

Page 19: Bioluminescence: Luciferin-Lucferase ATP Detection Assay

We can detect ATP. So what?• ATP is required for cellular

metabolism9

• “… each human being recycles the equivalent of his/her own mass of ATP every day.”9

• Extracellular ATP concentrations are critical in biological receptor response10

Image from: http://www.bris.ac.uk/Depts/Chemistry/MOTM/atp/atp1.htm

Page 20: Bioluminescence: Luciferin-Lucferase ATP Detection Assay

Areas of interest for ATP quantitation

• The Mitochondria – the “powerhouse” of the cell– Complex system– ATP is produced

and sent to the cell

• Implications in cardiomyopathies

Mitochondrial ADP/ATP Carrier (Figure 1) Citation 9

Page 21: Bioluminescence: Luciferin-Lucferase ATP Detection Assay

Rapid Hygiene Tester (Biothema)

• Detect ATP (quickly) down to very low detection – i.e. ATP in one animal cell

(~ 1 pg)• Also developed to test

AMP as well (bi-product of ATP breakdown)

• Important in the food production industry, labs, hospitals, etc.

Citation 11

Page 22: Bioluminescence: Luciferin-Lucferase ATP Detection Assay

Conclusions• Chemiluminescence and Bioluminescence are

common, extremely versatile, and useful analytical tools

• HTS methods are becoming increasingly more dependent upon this “background-free” technique

• The ATP Detection Assay could have huge implications in pharmacology as it evolves for different types of detection

Page 23: Bioluminescence: Luciferin-Lucferase ATP Detection Assay

Works Cited 1. "Chemiluminescence." Lumigen, INC - A Beckman Coulter Company. Web. 07 Feb. 2011.

<http://www.lumigen.com/detection_technologies/chemiluminescence/>.2. Fan, Frank, and Keith V. Wood. "Technology Review: Bioluminescent Assays for High-Throughput Screening." ASSAY and Drug

Development Technologies 5.1 (2006): 127-36.Fan, Frank and Wood V. Keith. ASSAY and Drug Development Technolgoies. V5, N1. 2007.

3. "Luminometer Comparison Chart of Microplate/Multiwell and Single Tube Luminometers from Promega." Promega Luminometers, Fluorometers, and Multimode Readers. Web. 07 Feb. 2011. http://www.luminometer.com/instruments/luminometers-dual-luciferase-ATP-ELISA.php?gclid=CIel3d-r9qYCFYbb4Aodw3MjFg.

4. Karamohamed, Samer, and Guido Guidotti. "Bioluminometric Method for Real-Time Detection of ATPase Activity." BioTechniques 31 (2001): 420-25.

5. Hoshino, Hideto. "Current Advanced Bioluminescence Technology in Drug Discover." Expert Opinion in Drug Discovery 4.4 (2009): 373-89.

6. Roda, Aldo, Patrizia Pasini, Mara Mirasoli, Elisa Michelini, and Massimo Guardigli. "Biotechnological Applications of Bioluminescence Adn Chemiluminescence." TRENDS in Biotechnology 22.6 (2004): 295-303.

7. Gregory, Kalvin J., Ye Sun, Nelson G. Chen, and Valeri Golovlev. "Real-time Bioluminescent Assay for Inhibitors of RNA and DNA Polymerases and Other ATP-dependent Enzymes." Analytical Biochemistry 408 (2011): 226-34.

8. "ATP Determination Kit (A22066)." Product Information: Molecular Probe: Invitrogen detection technologies. Revised 29-Nov-2005.

9. Dahout-Gonzalez, C., H. Nury, V. Trezequet, J. M. Lauquin, E. Pebay-Peyroula, and G. Brandolin. "Molecular, Functional, and Pathological Aspects of the Mitochondrial ADP/ATP Carrier." PHYSIOLOGY 21 (2006): 242-49.

10. Seminario-Vidal, Lucia, Eduardo R. Lazarowski, and Seiko F. Okada. "Assessment of Extracellular ATP." Bioluminescence, Methods in Molecular Biology 574 (2009): 25-36.

11. "Can You Say It's Clean with Confidence?" BioThema - Luminescence Analysis, We Sell Our Kits and Reagents Worldwide. Web. 14 Feb. 2011. <http://www.biothema.com/news_newsdetail.do;jsessionid=A047393FA5453A636E59B387B9B173B6?newsentryid=12 〈 =en>.

Page 24: Bioluminescence: Luciferin-Lucferase ATP Detection Assay

Works Cited – Other Helpful Websites

• http://uvminerals.org/fms/luminescence– Great website which clarifies VERY well the

differences in luminescence

• http://www.photobiology.info/Branchini.htm– Great website to visit if you want a better

understanding of the chemistry

Page 25: Bioluminescence: Luciferin-Lucferase ATP Detection Assay

Example of QC in GPCR assay

• Dual-Luciferase assay– Helps to account for interferences (i.e. from cytotoxic compounds) which

could effect results (false -/+’s) – Plasmid 1 – firefly luciferase gene, marker, and response element of

interest– Plasmid 2 – GPCR of interest and Renilla luciferase marker fusion protein

(Figure 4) Citation 2

Page 26: Bioluminescence: Luciferin-Lucferase ATP Detection Assay

Example of Luciferin Detection (comparing fluorescence and

bioluminescence)

(Figure 7) Citation 2

Page 27: Bioluminescence: Luciferin-Lucferase ATP Detection Assay

Example of an Actual ATP Standard Curve using an ATP

Detection Kit