AUTOMATIC SPRINKLERS UPRIGHT, PENDENT, HORIZONTAL SIDEWALL & CONCEALED PENDENT
BRISTOL Sprinkler System Datasheets Rev. 0 2
CO
NT
EN
TS
Upright Sprinkler ………….………….………….………….………….………….………….………….…………………... 3
Pendent Sprinkler ………….………….………….………….………….………….………….………….…………………. 3
Horizontal Sidewall Sprinkler ………….………….………….………….………….………….………….………….…….. 4
Concealed Pendent Sprinkler ………….………….………….………….………….………….………….………….…. 5
Alarm Check Valve ………….………….………….………….………….………….………….………….………………. 7
Deluge Valve ………….………….………….………….………….………….………….………….………………………. 8
Other Valve ………….………….………….………….………….………….………….………….……………………….. 9
CONTENTS
BRISTOL Sprinkler System Datasheets Rev. 0 3
AU
TO
MA
TIC
SP
RIN
KLE
R S
YS
TE
M
MODEL: BF001 / BF005 / BF002 / BF004
STANDARD SPRAY, STANDARD / QUICK RESPONSE,
5/3mm BULB TYPE, K5.6, ½” CONNECTING THREAD
UPRIGHT SPRINKLERS AND
PENDENT SPRINKLERS
The BF001/BF005 Standard/Quick Response
Upright and BF002/BF004 Standard/Quick
Response Pendent.
Sprinklers (Ref. Figure A) are automatic sprin-
klers of the frangible bulb type. They are
“standard/quick response – standard orifice
spray sprinkler” intended for use in fire sprinkler
systems designed in accordance with the
standard installation rules recognized by the
applicable Listing or Approval agency (e.g.,
UL Listing is based on NFPA 13 requirements).
The Upright, Pendent Sprinklers all produce a
hemispherical water distribution pattern be-
low the deflector.
Sprinkler Operation
During a fire conditions, the thermal‐sensitive
liquid in the glass bulb expands, causing the
bulb to shatter, releasing the button and
spring seal assembly. Water flowing through
the sprinkler orifice strikes the sprinkler deflec-
tor, forming a uniform spray pattern to extin-
guish or control the fire.
Coverage
For coverage area and sprinkler placement,
refer to NFPA13 standards.
Description
Model & Sprinkler I.D. No. BF001 BF005 BF002 BF004
Style Upright Pendant
Bulb Nominal Dia. & Response
Ø5mm,
Standard
Response
Ø3mm,
Quick Re-
sponse
Ø5mm,
Standard
Response
Ø3mm, Quick
Response
Thread Size (Optional) NPT ½ or R ½
Nominal Orifice Size ½ Inch
Nominal K‐factor 5.6 (U.S.) / 80 (metric)
Max. Working Pressure 175 psig / 1.2 MPa (12 bar)
Factory Hydrostatic Test 100% @ 500 psig (3.4 MPa)
Min. Operating Pressure 7 psig / 0.048 MPa (0.48 bar)
Sprinkler Finish (Optional) Natural Brass / Chrome Plated / White Color Coated
Escutcheon Finish Chrome Plated or Color Coated in any color
Listings and Approvals UL (United States) / ULC (Canada)
Technical Specifications:
FIGURE A: MODEL BF001/BF005 UPRIGHT & MODEL BF002/BF004 PENDENT SPRINKLERS
Sprinkler Materials
Frame …………… Brass Casting DZR
Deflector……...… Brass UNS-2800
Glass Bulb……….. Glass with Glycerin Solution
JOB® G5 for BF001/BF002
JOB® F3 for BF005/BF004
Set Screw………... Brass UNS-28000
Button…………….. Brass UNS-28000
Spring……………… Stainless Steel
Seal………………… Teflon Tape
Standard Eskutcheon…… Cold Rolled Steel
AU
TO
MA
TIC
SP
RIN
KLE
R S
YS
TE
M
BRISTOL Sprinkler System Datasheets Rev. 0 4
MODEL: BF007 / BF008 STANDARD SPRAY, STAND-
ARD / QUICK RESPONSE, 5/3mm BULB TYPE, K5.6, ½”
CONNECTING THREAD
Description
Horizontal sidewall sprinklers are generally used in lieu of pendent
and upright sprinklers because of building construction or installa-
tion economy considerations. They are designed for installation
along a wall or the side of a beam and just beneath a smooth
ceiling. Installed with their centerline of waterway horizontal,
these sprinklers produce a quarter‐spherical water discharge pat-
tern that is predominately directed downward and outward from
the deflec or; however, a portion of the spray is also directed
towards the back wall.
Model BF007/BF008, Standard / Quick Response Horizontal Side-
wall Sprinklers (Ref. Figure A), are automatic sprinklers of the
frangible bulb type, and standard spray, 1/2” orifice, 5 / 3 mm
bulb. They are “standard / quick response ‐ standard orifice sidewall
sprinklers” intended for use in fire sprinkler systems designed in ac-
cordance with the standard installation rules recognized by the ap-
plicable Listing or Approval agency (e.g., UL Listing is based on NFPA
13 requirements)
Sprinkler Operation
During a fire conditions, the thermal‐sensitive liquid in the glass
bulb expands, causing the bulb to shatter, releasing the button
and spring seal assembly. Water flowing through the sprinkler ori-
fice strikes the sprinkler deflector, forming a uniform spray pattern
to extinguish or control the fire.
Coverage
For coverage area and sprinkler placement,
refer to NFPA13 standards.
Model & Sprinkler I.D. No. BF007 BF008
Style Horizontal Sidewall
Bulb Nominal Dia. & Response Ø5mm, Standard
Response
Ø3mm, Quick Re-
sponse
Thread Size (Optional) NPT ½ or R ½
Nominal Orifice Size ½ Inch
Nominal K‐factor1 5.6 (U.S.) / 80 (metric)
Max. Working Pressure 175 psig / 1.2 MPa (12 bar)
Factory Hydrostatic Test 100% @ 500 psig (3.4 MPa)
Min. Operating Pressure 7 psig / 0.048 MPa (0.48 bar)
Sprinkler Finish (Optional) Natural Brass / Chrome Plated / White Color
Coated
Listings and Approvals UL (United States) / ULC (Canada)
Technical Specifications:
Sprinkler Materials
Frame ………………………… Brass Casting DZR
Deflector……………………… Brass UNS-2800
Glass Bulb…………………….. Glass with Glycerin Solution
JOB® G5 for BF007
JOB® F3 for BF008
Set Screw……………………... Brass UNS-28000
Button………………………….. Brass UNS-28000
Spring…………………………… Stainless Steel
Seal……………………………… Teflon Tape
Standard Eskutcheon………… Colrd Rolled Steel FIGURE B: MODEL BF007 / BF008 HORIZONTAL SIDEWALL SPRINKLERS
HORIZONTAL SIDEWALL
SPRINKLER
AU
TO
MA
TIC
SP
RIN
KLE
R S
YS
TE
M
BRISTOL Sprinkler System Datasheets Rev. 0 5
MODEL: BF007 / BF008 STANDARD SPRAY, STAND-
ARD / QUICK RESPONSE, 5/3mm BULB TYPE, K5.6, ½”
CONNECTING THREAD
Description
The BF003/BF006 Standard/Quick Response Concealed Pendent Sprin-
klers (Ref. Figure A) are automatic sprinklers of the frangible bulb type.
They are “standard/quick response – standard orifice spray sprinkler”
intended for use in fire sprinkler systems designed in accordance with
the standard installation rules recognized by the applicable Listing or
Approval agency (e.g., UL Listing is based on NFPA 13 requirements).
The Concealed Pendent Sprinklers all produce a hemispherical water
distribution pattern below the deflector.
This model sprinkler includes a Cover Plate Assembly that conceals the
sprinkler operating components above the ceiling. The Cover Plate
Assembly, which installs onto the Sprinkler/ Mounting Cup Assembly,
consists of a Cover Plate that is soldered to an Enclosure at three equi-
distant locations around their peripheries. The Ejection Spring is located
between the flange of the Enclosure and the Cover Plate, to ensure
separation of the two pieces when the solder melts.
A Label located on the Cover Plate Assembly indicates the nominal
temperature of the sprinkler and the nominal diameter of the Glass
Bulb.
The small Cover Plate is flat with a low profile that blends in with
the ceiling for an aesthetically pleasing appearance. Standard
finishes for the Cover Plate are satin chrome plated and painted
white. Other factory applied painted finishes for the Cover Plate is
available on special order
The separable two‐piece design of the Cover Plate and Mounting
Cup Assemblies allows installation of the sprinklers and pressure
testing of the fire protection system prior to installation of a sus-
pended ceiling or application of the finish coating to a fixed ceiling.
The separable design also permits removal of suspended ceiling panels
for access to building service equipment, without having to first shut
down the fire protection system and remove sprinklers.
Also, the separable two piece design of the BF003 / BF006 Concealed
Sprinkler provides for 1/6 inch (4.2mm) of vertical adjustment, to re-
duce the accuracy to which the length of fixed pipe drops to the
sprinklers must be cut
Sprinkler Operation
During a fire conditions, the thermal‐sensitive liquid in the glass
bulb expands, causing the bulb to shatter, releasing the button
and spring seal assembly. Water flowing through the sprinkler ori-
fice strikes the sprinkler deflector, forming a uniform spray pattern
to extinguish or control the fire.
Coverage
For coverage area and sprinkler placement,
refer to NFPA13 standards.
Model & Sprinkler I.D. No. BF003 BF006
Style Concealed Pendent
Bulb Nominal Dia. & Response Ø5mm, Standard
Response
Ø3mm, Quick Re-
sponse
Thread Size (Optional) NPT ½ or R ½
Nominal Orifice Size ½ Inch
Nominal K‐factor1 5.6 (U.S.) / 80 (metric)
Max. Working Pressure 175 psig / 1.2 MPa (12 bar)
Factory Hydrostatic Test 100% @ 500 psig (3.4 MPa)
Min. Operating Pressure 7 psig / 0.048 MPa (0.48 bar)
Sprinkler Finish (Optional) Natural Brass / Chrome Plated / White Color
Coated
Listings and Approvals UL (United States) / ULC (Canada)
Technical Specifications:
Sprinkler Materials
Frame ………………………… Brass Forgoin UNS-C87400
Deflector……………………… Brass UNS-2800
Glass Bulb…………………….. Glass with Glycerin Solution
JOB® G5 for BF003
JOB® F3 for BF006
Set Screw……………………... Brass UNS-28000
Button………………………….. Brass UNS-28000
Mounting Cup………………… Low Carbon Sheet Steel UNS-G10080
Enclosure……………………….. Brass UNS-C2800
Ejection Spring…………………. Stainless Steel UNS-s30452
Spring…………………………… Stainless Steel
Seal……………………………… Teflon Tape
Label……………………………. Mylar (Sticky - Back)
FIGURE C: MODEL BF003 / BF006 CONCEALED PENDENT SPRINKLERS
CONCEALED PENDENT
SPRINKLER
BRISTOL Sprinkler System Datasheets Rev. 0 6
AU
TO
MA
TIC
SP
RIN
KLE
R S
YS
TE
M
Temp. Classification Ordinary Ordinary Intermediate Intermediate
Nominal Temp. Rating 135⁰F / 57⁰C 155⁰F / 68⁰C 175⁰F / 79⁰C 200⁰F / 93⁰C
Max. Ambient Temp. Allowed ⁵
115⁰F / 46⁰C
135⁰F / 57⁰C
155⁰F / 68⁰C
180⁰F / 82⁰C
Max. Recommended Ambient Temp. ⁶
100⁰F / 38⁰C
100⁰F / 38⁰C
150⁰F / 65⁰C
150⁰F / 65⁰C
Glass Bulb Color Orange Red Yellow Green
Available Temperature Rating
Discharge Coefficient
Sprinklers are rated for use at a maximum service pressure of 175
psig (12 bar). The nominal discharge curve plotted in Figure B
represents the flow “Q” in GPM (LPM) as determined by the fol-
lowing formula:
Q = K (P) 0.5
Q = Flow, GPM (LPM)
K = Discharge Coefficient, K = 5.6 (80)
P = Discharge Pessure, psig (bar)
MODEL: BF001 / BF005 / BF002 / BF004 /
BF003 / BF006 / BF007 / BF008
STANDARD SPRAY, STANDARD / QUICK
RESPONSE,
5/3mm BULB TYPE, K5.6, ½” CONNECTING
THREAD
Where,
Standard Escutcheon
Type E‐1
Installation Wrench
Type T‐1
Accessories
BRISTOL Sprinkler System Datasheets Rev. 0 7
AU
TO
MA
TIC
SP
RIN
KLE
R S
YS
TE
M
ALARM CHECK VALVE
Standard ………………………… ANSI/UL 193
Sizes :……………………………….4”/DN100 & 6” /DN150
Inlet Connection :………………. Flanged Class 150 ANSI
B16.1
Max. Working Pressure :………… 175psi / 12bar
Test Pressure :…………………….. 350psi / 24bar
Body Material :…………………… Ductile Iron
Accessories :……………………… Retard Chamber, Wa-
ter Motor Alarm, Alarm Pressure Switch
Standard Finish :………………….. RAL 3000 (Flame Red)
Model BAV-146 Alarm Check Valve is a wet pipe sprin-
kler system water supply check valve that makes
possible the installation of sprinkler systems in buildings
not subject to freezing temperatures. It is designed so
that water pressure in the piping system will hold back
water pressure at the valve until a significant flow of
water occurs. The Alarm Check Valve serves as a
check valve by trapping pressurized water above the
clapper and preventing reverse flow from sprinkler
piping.
Size 4" (DN100) 6" (DN150)
Inlet Connection Style Flange Groove Flange Groove
Outlet Connection Style Flange Groove Flange Groove
Shipping Weight 55 lbs∕25 kg 51 lbs∕23 kg 75 lbs∕34 kg 66 lbs∕30 kg
Max. Working Pressure 175 psig∕1.2 MPa (12 bar)
Factory Hydro Test 100% @ 350 psig∕2.4 MPa (24 bar)
Standard Finish Red Painted
Flange & Groove Specification Flange: Class 150 ANSI B16.1 & Groove: C606 ANSI∕AWWA
Required Accessories Standard Trim
Optional Accessories Retard Chamber, Water Motor Alarm, Alarm Pressure Switch
Installation Manner Vertically
Listings and Approvals UL (United States)
Valve Size H H1 H2 H3 H4 H5 H6 RefH7 H8 OD D1 D2 D3
4" Flange 270 2.0 23.9 40 83 193 230 77 103 Ø 228.6 Ø 190.5 Ø 157.5 Ø 19
6" Flange 346 2.0 23.9 53 111 270 244 76 132 Ø 279.4 Ø 241.3 Ø 215.9 Ø 23
DIMENSIONS
No. Part Name
1 Valve Body (Flanged Side)
2 Valve Body (Grooved Side)
3 Cover Plate
4 Seat Ring
5 Cover Plate Bolt
6 Spring Washer
7 Cover Plate Gasket
8 Clapper Seal Retainer
9 Clapper Seal
10 Clapper Screw
11 Clapper
12 Clapper Shaft
13 Clapper Bushing
BRISTOL Sprinkler System Datasheets Rev. 0 8
AU
TO
MA
TIC
SP
RIN
KLE
R S
YS
TE
M
DELUGE VALVE
For Solenoid Actuated
Available in sizes 4‖, 6‖, & 8‖
Quick response to air supply to pilot
No gland packing
Dry pilot trim when air is used for sprinkler system
BRISTOL DELUGE VALVE XT-4080P is used for Dry Pilot Trim-Air Operated Deluge System.
The valve can be used with direct air supply to the pilot in which case, the Deluge Valve
will open in case of Air Pressure Loss. The valve can also be used with Solenoid Valve,
where air is supplied to Pilot Valve through 3/2 way Solenoid Valve which keeps Deluge
Valve in closed condition.
In case of FIRE or TEST, the 3/2 way Solenoid Valve is energized, which removes air from
the Pilot Valve. This open the Pilot Valve and releases water from the cover chamber of
main valve which opens Main Valve - Deluge Valve.
PNEUMATIC/HYDRAULIC , XT-4080P
SOLENOID ACTUATED, XT-4080S
BRISTOL DELUGE VALVE XT-4080S (Solenoid Controlled) is
an ON/OFF control valve which either opens or closes
upon receiving an Electrical Signal to the Solenoid Pilot
Control. This valve consists of XT-4080 UL-listed Main
Valve, a 3/2 way Solenoid Valve, an Auxiliary Pilot and a
Manual Release Station.
The Pilot Control System applies line water pressure to or
relieves water pressure from the diaphragm chamber of
the main valve to close or open the Deluge Valve. It is
supplied either Normally Closed (Energize Solenoid to
open) or Normally Open (De-energize Solenoid Valve to
open)
For Pneumatic/Hydraulic
Available in sizes 4‖, 6‖, & 8‖
Fast-acting solenoid Control
Drip-Tight Shutoff
Simple Design-Pressure Reliability
Easy installation and maintenance without remov-
ing valve from the line
All Deluge Valve trims are pre-piped at factory
FEATURES
The valve opens on demand to provide water flow to
the fire protection sprinkler system. Pilot system can be
hydraulically, pneumatically or manually operated.
Opening of the Valve is by electrical signal to solenoid
valve/loss of control pressure.
BRISTOL DELUGE VALVE XT-4080S /XT-4080SP
Connection Type 4‖ / 6‖ / 8‖ Flanged to ANSI B16.5 Class 150 & 300
Pressure Rating 150 Class, Max 285psig (20barg)
300 Class, Max 375psig (26barg)
Temperature Range 70°C / 160°F Max. (Water)
Main Valve Body & Cover
Cast Steel ASTM A216 Gr. WCB
Naval Bronze: ASTM B61
Nickel Al-Bronze: ASTM B148/BS1400 Gr. AB2
Stainless Steel: ASTM A351 Gr. CF8/CF8M
Valve Seat Stainless Steel Gr. 316
All other internal parts Stainless Steel Gr. 304
Stem Stainless Steel Gr. 316
Pilot Stainless Steel
Tubing & Fitting Stainless Steel
Elastomers NBR / Buna-N Nylon Reinforced
Specifications & Materials
BRISTOL DELUGE VALVE XT-4080S /XT-4080SP
Valve DN (inches) 4” 6” 8”
Valve DN (mm) 100 150 200
Valve Cover Chamber Capacity (L) 0.616 1.96 4.73
Flow Rate (gpm @ 1psi Δ P) 220 460 840
Max. Continuous Flow Rate (gpm, Water) 800 1800 3100
Max. Intermittent Flow Rate (gpm, Water) 1000 2300 3900
Approx. Weight (kgs) 55 115 182
BRISTOL Sprinkler System Datasheets Rev. 0 9
AU
TO
MA
TIC
SP
RIN
KLE
R S
YS
TE
M
Test & Drain Valve, BF-VT001
Standard ………………………… UL Subject 258
Connection Type……………….. 1” M x F NPT
Body Material :…………………… Brass
Working Pressure :………………. 175psig / 12bar
K Factor :…………………………. 5.6
Air Release Valve, BFE090203
Standard ………………………… BS5041-3
Test Pressure : ……………………. 24bar
Inlet Coupling Type :...…………. DN25 Male BSPT
Max. Working Pressure :………… 175psi / 12bar
Body Material :…………………… Brass
Body Color :……………………….. Cast Brass