www.tridonic.com 1Subject to change without notice.Data sheet 06/10-873-1
Digital dimmable ballasts for fluorescent lampsECO series
Product description
Processor-controlled ballast with y insideAutomatic lamp detection and operation
with correct lamp parameters
Noise-free precise control via DSI signal,
switchDIM or corridorFUNCTION
CELMA energy class A1 BAT
Interfaces
DSI
switchDIM (with memory function + selectable dimming rate)
corridorFUNCTION (3 preprogrammed profiles)
Integrated SMART-Interface
Functions
Intelligent Temperature Guard (protection against thermal damage)
Intelligent Voltage Guard (overvoltage indication
and undervoltage shutdown)
Optimum filament heating in any dimmer setting
Disconnection of filament heating from a dimming level of approx.
90 % for maximum energy efficiency (SMART-Heating Concept)
Automatically triggered emergency lighting value in DC mode, 70 %
For emergency lighting systems as per EN 50172
Automatic start after replacement of defective lamps
Backwards compatible
Standards, page 2
Wiring diagrams and installation examples, page 5
PCA T5 ECO lp Y 3 and 4x14/24 WT5 fluorescent lamps
T5
6
LD
3,5
4,1
4,1
4021
Technical dataPower input on standby < 0.5 W
Protective hot restart 0.5 s for AC / 0.2 s for DC
Dimming range, 3 lamps 5 100 %
Dimming range, 4 lamps 1 100 %
Operating frequency ~40 100 kHz
Life 50,000 h
Height 21 mm
Ordering dataType Article numberFor luminaires with 3 lamps
PCA 3x14/24 T5 ECO lp Y 22176211For luminaires with 4 lamps
PCA 4x14/24 T5 ECO lp Y 22176212Packaging 360 mm casing: 20 pieces/carton, 600 pieces/pallet
Specific technical dataLamp
wattageLamptype
Type Length L Hole spacing D
Weight Circuit power1
Lamp wattage1
Current at230 V / 50 Hz1
at230 V /50 Hz
tc point Ambienttemperature ta2
For luminaires with 3 lamps3 x 14 W T5 PCA 3x14/24 T5 ECO lp y 360 mm 350 mm 0.29 kg 46.5 W 42 W 0.21 A 0.97 75 C -25 ... 60 C3 x 24 W T5 PCA 3x14/24 T5 ECO lp y 360 mm 350 mm 0.29 kg 73.0 W 72 W 0.32 A 0.97 75 C -25 ... 55 CFor luminaires with 4 lamps4 x 14 W T5 PCA 4x14/24 T5 ECO lp y 360 mm 350 mm 0.33 kg 60.5 W 56 W 0.27 A 0.97 75 C -25 ... 60 C4 x 24 W T5 PCA 4x14/24 T5 ECO lp y 360 mm 350 mm 0.33 kg 97.5 W 96 W 0.43 A 0.97 75 C -25 ... 50 C1 Valid at 100 % dimming level
2 +10 C to ta max: unrestricted dimming. -25 C to +10 C: unrestricted dimming from 100 % to 30 %. -25 C to +10 C, dimming below 30 %: malfunction possible but no damage to ECG. This applies to AC and DC operation.
Enlightening your ideas
I want light I can rely on.Data sheets available at www.tridonic.com, Technical data menu
T catalogue Certificates at www.tridonic.com, Technical data menu
FLASH customer magazine
Art. no. 24166453 12/10 We reserve the right to make technical changes without prior notice. No liability can be assumed for the accuracy of data content.
FLASH THE TRIDONIC CUSTOMER MAGAZINE21
Country Special
Middle East
T LEDNew chains
and engines
PC INDUSTRY
Robust and durable
Magnetic ballasts for fluorescent lampsElectronic ballasts for fluorescent lampsDigital dimmable ballasts for fluorescent lampsMagnetic ballasts for HIDIgnitors and power switches for HIDElectronic ballasts for HIDMagnetic transformers for low-voltage halogen lampsElectronic transformers for low-voltage halogen lampsEmergency lighting unitsluxCONTROL lighting control systems v LED modules, converters and systems
Visit www.tridonic.com to find your personal contact at Tridonic.
Further information and ordering data:
Control gear, lighting control systems and LED
Asia Pacific Catalogue 2011
Asi
a P
acifi
cC
atal
ogue
201
1en
glis
h
-
www.tridonic.com 1Subject to change without notice.Data sheet 06/10-873-1
Digital dimmable ballasts for fluorescent lampsECO series
Product description
Processor-controlled ballast with y insideAutomatic lamp detection and operation
with correct lamp parameters
Noise-free precise control via DSI signal,
switchDIM or corridorFUNCTION
CELMA energy class A1 BAT
Interfaces
DSI
switchDIM (with memory function + selectable dimming rate)
corridorFUNCTION (3 preprogrammed profiles)
Integrated SMART-Interface
Functions
Intelligent Temperature Guard (protection against thermal damage)
Intelligent Voltage Guard (overvoltage indication
and undervoltage shutdown)
Optimum filament heating in any dimmer setting
Disconnection of filament heating from a dimming level of approx.
90 % for maximum energy efficiency (SMART-Heating Concept)
Automatically triggered emergency lighting value in DC mode, 70 %
For emergency lighting systems as per EN 50172
Automatic start after replacement of defective lamps
Backwards compatible
Standards, page 2
Wiring diagrams and installation examples, page 5
PCA T5 ECO lp Y 3 and 4x14/24 WT5 fluorescent lamps
T5
6
LD
3,5
4,1
4,1
4021
Technical dataPower input on standby < 0.5 W
Protective hot restart 0.5 s for AC / 0.2 s for DC
Dimming range, 3 lamps 5 100 %
Dimming range, 4 lamps 1 100 %
Operating frequency ~40 100 kHz
Life 50,000 h
Height 21 mm
Ordering dataType Article numberFor luminaires with 3 lamps
PCA 3x14/24 T5 ECO lp Y 22176211For luminaires with 4 lamps
PCA 4x14/24 T5 ECO lp Y 22176212Packaging 360 mm casing: 20 pieces/carton, 600 pieces/pallet
Specific technical dataLamp
wattageLamptype
Type Length L Hole spacing D
Weight Circuit power1
Lamp wattage1
Current at230 V / 50 Hz1
at230 V /50 Hz
tc point Ambienttemperature ta2
For luminaires with 3 lamps3 x 14 W T5 PCA 3x14/24 T5 ECO lp y 360 mm 350 mm 0.29 kg 46.5 W 42 W 0.21 A 0.97 75 C -25 ... 60 C3 x 24 W T5 PCA 3x14/24 T5 ECO lp y 360 mm 350 mm 0.29 kg 73.0 W 72 W 0.32 A 0.97 75 C -25 ... 55 CFor luminaires with 4 lamps4 x 14 W T5 PCA 4x14/24 T5 ECO lp y 360 mm 350 mm 0.33 kg 60.5 W 56 W 0.27 A 0.97 75 C -25 ... 60 C4 x 24 W T5 PCA 4x14/24 T5 ECO lp y 360 mm 350 mm 0.33 kg 97.5 W 96 W 0.43 A 0.97 75 C -25 ... 50 C1 Valid at 100 % dimming level
2 +10 C to ta max: unrestricted dimming. -25 C to +10 C: unrestricted dimming from 100 % to 30 %. -25 C to +10 C, dimming below 30 %: malfunction possible but no damage to ECG. This applies to AC and DC operation.
Enlightening your ideas
I want light I can rely on.Data sheets available at www.tridonic.com, Technical data menu
T catalogue Certificates at www.tridonic.com, Technical data menu
FLASH customer magazine
Art. no. 24166453 12/10 We reserve the right to make technical changes without prior notice. No liability can be assumed for the accuracy of data content.
FLASH THE TRIDONIC CUSTOMER MAGAZINE21
Country Special
Middle East
T LEDNew chains
and engines
PC INDUSTRY
Robust and durable
Magnetic ballasts for fluorescent lampsElectronic ballasts for fluorescent lampsDigital dimmable ballasts for fluorescent lampsMagnetic ballasts for HIDIgnitors and power switches for HIDElectronic ballasts for HIDMagnetic transformers for low-voltage halogen lampsElectronic transformers for low-voltage halogen lampsEmergency lighting unitsluxCONTROL lighting control systems v LED modules, converters and systems
Visit www.tridonic.com to find your personal contact at Tridonic.
Further information and ordering data:
Control gear, lighting control systems and LED
Asia Pacific Catalogue 2011
Asi
a P
acifi
cC
atal
ogue
201
1en
glis
h
-
Mag
netic
bal
last
sFi
xed-
outp
ut E
CGDi
gita
l dim
mab
le
balla
sts
HID
mag
netic
bal
last
sIg
nito
rs a
ndpo
wer s
witc
hes
Mag
netic
tran
sfor
mer
sEl
ectro
nic
trans
form
ers
Emer
genc
y lig
htin
g un
itslu
xCON
TROL
ligh
ting
cont
rol s
yste
ms
LED
syst
ems
uAp
pend
ixIn
dex
HID
elec
troni
c ba
llast
s
Magnetic ballasts for fluorescent lamps
Electronic ballasts for fluorescent lamps
Digital dimmable ballasts for fluorescent lamps
Magnetic ballasts for HID
Ignitors and power switches for HID
Electronic ballasts for HID
Magnetic transformers for low-voltage halogen lamps
Electronic transformers for low-voltage halogen lamps
Emergency lighting units
luxCONTROL lighting control systems
u LED modules, converters and systems
Appendix
Index
Page 5
Page 77
Page 123
Page 187
Page 271
Page 303
Page 339
Page 359
Page 381
Page 455
Page 521
Page 635
Page 657
-
Mag
netic
bal
last
s
www.tridonic.com 5Asia Pacific Catalogue 2011
Suitable for lamp type
T5 T8 CFL
Magnetic ballasts for fluorescent lamps
Overview
Product overview
Standards
Product information
Fluorescent lamps
Magnetic ballasts for fluorescent lamps
Fluorescent lamp ballast guide
Technical tips for fluorescent lamp circuits
EC series
Linear and circular fluorescent lamps, 220 V 50 Hz
EC 6 13 W, baseplate 85 mm, push-in terminals
EC 10 40 W, baseplate 150 mm, push-in terminals
EC 15 40 W, baseplate 150 mm, screw terminals
EC 58 65 W, baseplate 195 mm, push-in terminals
EC 58 65 W, baseplate 195 mm, screw terminals
Compact fluorescent lamps, 220 V 50 Hz
EC 5 18 W, baseplate 85 mm, push-in terminals
EC 18 38 W, baseplate 150 mm, push-in terminals
EC 18 38 W, baseplate 150 mm, screw terminals
Linear and circular fluorescent lamps, 220 V 60 Hz
EC 4 13 W, baseplate 85 mm, push-in terminals
EC 6 13 W, baseplate 85 mm, screw terminals
EC 18 40 W, baseplate 150 mm, push-in terminals
EC 18 36 W, baseplate 150 mm, screw terminals
EC 58 65 W, baseplate 195 mm, screw terminals
Compact fluorescent lamps, 220 V 60 Hz
EC 5 18 W, baseplate 85 mm, push-in terminals
EC 5 13 W, baseplate 85 mm, screw terminals
EC 5 38 W, baseplate 150 mm, push-in terminals
EC 18 36 W, baseplate 150 mm, screw terminals
Linear and circular fluorescent lamps, 230 V 50 Hz
EC 6 13 W, baseplate 85 mm, push-in terminals
EC 15 40 W, baseplate 150 mm, push-in terminals
EC 18 40 W, baseplate 150 mm, screw terminals
EC 18 65 W, baseplate 195 mm, push-in terminals
EC 58 65 W, baseplate 225 mm, push-in terminals
Compact fluorescent lamps, 230 V 50 Hz
EC 5 18 W, baseplate 85 mm, push-in terminals
EC 18 38 W, baseplate 150 mm, push-in terminals
EC 18 38 W, baseplate 150 mm, screw terminals
EC 18 38 W, baseplate 195 mm, push-in terminals
Page 10
Page 8
Page 8
Page 9
Page 10
Page 18
Page 19
Page 21
Page 22
Page 23
Page 24
Page 26
Page 28
Page 29
Page 30
Page 31
Page 32
Page 33
Page 34
Page 35
Page 36
Page 38
Page 39
Page 45
Page 46
Page 48
Page 40
Page 42
Page 43
Page 44
Page 12
Page 16
Page 17
Page 49
-
Mag
netic
bal
last
s
www.tridonic.com 7Asia Pacific Catalogue 2011
Suitable for lamp type
T5 T8 CFL
Linear and circular fluorescent lamps, 240 V 50 Hz
EC 4 13 W, baseplate 85 mm, push-in terminals
EC 6 13 W, baseplate 110 mm, push-in terminals
EC 18 40 W, baseplate 150 mm, ConCut terminals
EC 10 40 W, baseplate 150 mm, push-in terminals
EC 18 40 W, baseplate 150 mm, screw terminals
EC 18 40 W, baseplate 195 mm, ConCut terminals
EC 18 65 W, baseplate 195 mm, push-in terminals
EC 58 65 W, baseplate 225 mm, push-in terminals
Compact fluorescent lamps, 240 V 50 Hz
EC 5 18 W, baseplate 85 mm, push-in terminals
EC 5 18 W, baseplate 110 mm, push-in terminals
EC 18 38 W, baseplate 150 mm, ConCut terminals
EC 5 38 W, baseplate 150 mm, push-in terminals
EC 18 38 W, baseplate 150 mm, screw terminals
EC 18 38 W, baseplate 195 mm, ConCut terminals
EC 18 38 W, baseplate 195 mm, push-in terminals
Linear and circular fluorescent lamps, 250 V 50 Hz
EC 32 W, baseplate 150 mm, push-in terminals
EC 18 40 W, baseplate 195 mm, push-in terminals
Compact fluorescent lamps, 250 V 50 Hz
EC 18 38 W, baseplate 195 mm, push-in terminals
OM series
Linear and circular fluorescent lamps, 240 V 50 Hz
OMC 18 40 W, baseplate 110 mm
Compact fluorescent lamps, 240 V 50 Hz
OMC 18 38 W, baseplate 110 mm
AC series
Compact fluorescent lamps, 240 V 50 Hz
AC 7 11 W
Wiring diagrams and installation examples
Page 56
Page 57
Page 58
Page 68
Page 69
Magnetic ballasts for fluorescent lamps
Page 50
Page 51
Page 52
Page 53
Page 55
Page 70
Page 71
Page 72
Page 74
Page 65
Page 59
Page 61
Page 62
Page 63
Page 67
Page 73
Page 66
-
www.tridonic.com8 Asia Pacific Catalogue 2011
Magnetic ballasts for fluorescent lampsOverview
EC
Portfolio: T5, T8, T12, TC-D, TC-DD, TC-F,
TC-L, TC-S
Magnetic ballasts for linear and compact fluorescent lamps:
Max. winding temperature tw = 130 C
AC
Portfolio: TC-S
Remote gear for compact fluorescent lamps:
Max. ambient temperature 40 C
Screw terminal
OM
Portfolio: T8, T12, TC-D, TC-DD, TC-F, TC-L
Magnetic ballasts for linear and compact fluorescent lamps:
Max. winding temperature tw = 130 C
Screw terminal 1.5 6 mm
Product overview
-
Mag
netic
bal
last
s
www.tridonic.com 9Asia Pacific Catalogue 2011
Standards
Magnetic ballasts for fluorescent lampsOverview
IEC
6092
1
IEC
6134
7-1
IEC
6134
7-2/
8
Series Voltage / Frequency Design Type Page
EC 220 V 50 Hz Linear and circular fluorescent lamps EC 6 13 W, baseplate 85 mm, push-in terminals Page 18 EC 10 40 W, baseplate 150 mm, push-in terminals Page 19
EC 15 40 W, baseplate 150 mm, screw terminals Page 21
EC 58 65 W, baseplate 195 mm, push-in terminals Page 22
EC 58 65 W, baseplate 195 mm, screw terminals Page 23
Compact fluorescent lamps EC 5 18 W, baseplate 85 mm, push-in terminals Page 24
EC 18 38 W, baseplate 150 mm, push-in terminals Page 26
EC 18 38 W, baseplate 150 mm, screw terminals Page 28
220 V 60 Hz Linear and circular fluorescent lamps EC 4 13 W, baseplate 85 mm, push-in terminals Page 29
EC 6 13 W, baseplate 85 mm, screw terminals Page 30
EC 18 40 W, baseplate 150 mm, push-in terminals Page 31
EC 18 36 W, baseplate 150 mm, screw terminals Page 32
EC 58 65 W, baseplate 195 mm, screw terminals Page 33
Compact fluorescent lamps EC 5 18 W, baseplate 85 mm, push-in terminals Page 34
EC 5 13 W, baseplate 85 mm, screw terminals Page 35
EC 5 38 W, baseplate 150 mm, push-in terminals Page 36
EC 18 36 W, baseplate 150 mm, screw terminals Page 38
230 V 50 Hz Linear and circular fluorescent lamps EC 6 13 W, baseplate 85 mm, push-in terminals Page 39
EC 15 40 W, baseplate 150 mm, push-in terminals Page 40
EC 18 40 W, baseplate 150 mm, screw terminals Page 42
EC 18 65 W, baseplate 195 mm, push-in terminals Page 43
EC 58 65 W, baseplate 225 mm, push-in terminals Page 44
Compact fluorescent lamps EC 5 18 W, baseplate 85 mm, push-in terminals Page 45
EC 18 38 W, baseplate 150 mm, push-in terminals Page 46
EC 18 38 W, baseplate 150 mm, screw terminals Page 48
EC 18 38 W, baseplate 195 mm, push-in terminals Page 49
240 V 50 Hz Linear and circular fluorescent lamps EC 4 13 W, baseplate 85 mm, push-in terminals Page 50
EC 6 13 W, baseplate 110 mm, push-in terminals Page 51
EC 18 40 W, baseplate 150 mm, ConCut terminals Page 52
EC 10 40 W, baseplate 150 mm, push-in terminals Page 53
EC 18 40 W, baseplate 150 mm, screw terminals Page 55
EC 18 40 W, baseplate 195 mm, ConCut terminals Page 56
EC 18 65 W, baseplate 195 mm, push-in terminals Page 57
EC 58 65 W, baseplate 225 mm, push-in terminals Page 58
Compact fluorescent lamps EC 5 18 W, baseplate 85 mm, push-in terminals Page 59
EC 5 18 W, baseplate 110 mm, push-in terminals Page 61
EC 18 38 W, baseplate 150 mm, ConCut terminals Page 62
EC 5 38 W, baseplate 150 mm, push-in terminals Page 63
EC 18 38 W, baseplate 150 mm, screw terminals Page 65
EC 18 38 W, baseplate 195 mm, ConCut terminals Page 66
EC 18 38 W, baseplate 195 mm, push-in terminals Page 67
250 V 50 Hz Linear and circular fluorescent lamps EC 32 W, baseplate 150 mm, push-in terminals Page 68
EC 18 40 W, baseplate 195 mm, push-in terminals Page 69
Compact fluorescent lamps EC 18 38 W, baseplate 195 mm, push-in terminals Page 70
OM 240 V 50 Hz Linear and circular fluorescent lamps OMC 18 40 W, baseplate 110 mm Page 71 Compact fluorescent lamps OMC 18 38 W, baseplate 110 mm Page 72
AC 240 V 50 Hz Compact fluorescent lamps AC 7 11 W Page 73
If country-specific approvals are required, please contact your local sales office.
-
www.tridonic.com10 Asia Pacific Catalogue 2011
Fluorescent lamps
OperationA fluorescent lamp is a type of low pressure mercury discharge lamp. A discharge arc operates in a glass tube internally coated with a phosphor powder. The electrical discharge produces mostly ultraviolet and some blue and green light. The phosphor coatingconverts the ultraviolet energy produced by the dis-charge into light. Cathodes, coated with an electron emitting material are sealed into each end of the glass envelope and connected to the pins of the lamp caps.The lamp contains gases such as argon and krypton with a drop of liquid mercury.
A control circuit is required which first causesan electric current to flow through each cathode.When the cathode filaments are heated, the emitter coating emits a cloud of electrons, which arenegatively charged. The electrons are acceleratedby a voltage applied across the lamp, producingionisation. The current flow through the lamp is then limited by the external control circuit.
The inert gas used in traditional fluorescent lamps is argon, krypton or a mixture of both. The improvement in efficacy achieved using krypton offers a powersaving approaching 8 % which translates directly into lower energy costs.
FlickerFluorescent lamps typically exhibit very little flicker( flicker factor 0.5 % or less ). However, stroboscopic effects from rotating parts or parts with reciprocalmotion can cause problems. These can be reducedby connecting lamps to different phases or by the use of lead-lag circuits or electronic ( high frequency )ballasts.
Electrical measurementsAll electrical measurements on lamp or circuit voltage, current and wattage have to be made with instruments of the true RMS type allowing for crest factors of upto 2.5.
Magnetic ballasts for fluorescent lampsProduct information
De-activation of excited mercury atoms produce UV photon and is convertedto visible light by the internal phosphor coating of the fluorescent lamp.
-
Mag
netic
bal
last
s
www.tridonic.com 11Asia Pacific Catalogue 2011
Magnetic ballasts for fluorescent lampsProduct information
Operating performanceThe performance of a fluorescent lamp is dependent upon not only the control circuit, but also on the ambient temperature. This influences the gas pressure in the lamp which in turn determines the yield of UV radiation.The optimum light output occurs when the lamp walltemperature is approximately 40 C ( for T8 / T12 lamps )at the cold spot ( fig.1 ).
This highlights the problems encountered in brightness control of fluorescent lamps if widely varying ambient temperatures prevail. It also shows that high opencircuit voltages are required to reliably start the lampin low temperature conditions ( fig. 2 ).
The more reliable starting, however, of control gear with high open circuit voltages is negated by the increased probability of cold starts occurring. Cold start is striking the arc before the cathodes are fully heated. It hasa detrimental effect on lamp life and, coupled withfrequent switching, can reduce lamp life to one quarteror less. Cold starts are more likely to occur with lamps of low operating voltage, such as 18 W 600 mm lampwith only 57 V across the lamp. The life of a fluorescent lamp is dependent to a certain degree on the frequency of switching on and off. A lamp which is switchedinfrequently will last considerably longer ( fig. 3 ).
The effect of mains voltage variations on the operating characteristics of fluorescent lamps is indicated inthe graph ( fig. 4 ). Increases in the mains voltage caninfluence lamp life in proportion to the increases in the lamp current.
Fig. 1
Typical relationship between temperature and lumen output
Fig. 2
Start voltage versus ambient temperature
Fig. 3
Typical effect on life of switching
Fig. 4
-
www.tridonic.com12 Asia Pacific Catalogue 2011
Magnetic ballasts for fluorescent lamps
A ballast is required to run a fluorescent lamp. This isa current limiting device which works on the self induc-tance principle. The impedance of the ballast is set to match the arc voltage of the lamp which ensures that the correct current is supplied. In some cases a ballast can be used for more than one lamp but the lampshould never be used with any other ballast than theone specifically designed for the job. Also any supply voltage or frequency variation will affect the optimumperformance of the ballast, and hence the lamp, sothe type with the correct values should always be used.
Optimum performanceThis is achieved by maintaining careful controlof the main parameters.
Preheat currentThis is supplied to the cathodes prior to the striking voltage. Without the correct preheat current, thecathodes would be progressively damaged resultingin short lamp life.
Strike voltageIn the case of a glow starter, this is produced by the ballast when the starter switch opens. The required voltage increases at high and low temperatures, and electronic starters may be required in abnormaltemperature conditions.
For a fluorescent lamp to operate constantly thesupply voltage must be at least twice the lamp voltage. If it is less, then an auto transformer is required to step up the voltage.
Lamp currentThe tight tolerances used in manufacture ensure that the impedance is the correct value for the correct lamp current and hence lamp wattage and luminous flux.
Minimum power lossesAn inefficient ballast means high losses, which in turn leads to high temperatures. This means the lamp runs out of its optimum temperature range and, in some cases, other components in the luminaire, such ascapacitors, will also run too hot and fail prematurely.
Tridonic have designed ballasts with minimal losses through the optimum use of windings within thebobbin. They have compact dimensions and usethe highest quality materials in their manufacture.
The losses ( lamp and ballast ) are rated in accordance with the ballast-lamp circuit ( EEI ) classification.
Selection of the right ballastTridonic offers ballasts in the following energy classes: standard ( EEI = C ) low loss ( EEI = B2 ) low loss ( EEI = B1 )
Each version has the same impedance and providesthe same lamp current. The difference is that the losses, and temperature rise, are progressively less, which can be seen from the data.
Magnetic ballasts for fluorescent lampsProduct information
-
Mag
netic
bal
last
s
www.tridonic.com 13Asia Pacific Catalogue 2011
Magnetic ballasts for fluorescent lampsProduct information
There are two reasons to select lower loss ballasts:
Energy consumptionA low loss B2 ballast typically consumes 30 % lesspower than a standard C ballast, and a low loss B1 ballast uses 67 % less power than a standard Cballast.
Temperature riseA typical standard C ballast will increase in tempera-ture by 55 K ( Kelvin ) above its surroundings, a low loss B2 ballast 35 - 40 K and a low loss B1 ballast 25 K.
When considering dimensions, Tridonic ballastshave optimised dimensions to minimise losses butlower loss ballasts do have increased dimensions.
As the measured power consumption dependsstrongly on the method of measurement, differences up to 10 K are possible in the results.
Long service lifeThe choice of insulating materials and their opera-ting temperatures determine the ballast life. Tridonicballasts use class H insulation materials whichare designed for temperatures up to 180 C, thusensuring maximum service life.
The permitted maximum working temperature ofthe winding is designated tw. The adherence to thistemperature guarantees an average life of 10 years continuous usage. If the temperature in applicationis lower, then the life is correspondingly higher.
The designation t is the temperature rise in degrees Celsius operating under prescribed conditions at rated voltage and is a function of ballast power losses. The difference between the tw rating and t is an indi-cation of the ambient temperature in which the ballast can operate. This is a very important consideration.
The graph shows the theoretical service life of a ballast against winding temperature. Every 10 C over themaximum winding temperature of 130 C ( tw130 )halves ballast life. The winding temperature is theambient temperature plus t or temperature risewhich is a function of ballast power consumption( watts loss ).
-
www.tridonic.com14 Asia Pacific Catalogue 2011
The high quality and reliability of insulated conductors is dependent not only on the production process,but also on the choice of raw materials. Many yearsof experience, both as a user and manufacturerof enamelled winding wire has given Tridonic theknowledge and expertise to select the best rawmaterials from internationally approved suppliers.
The copper is made from a high conductivity hotrolled copper rod and complies with the chemicalcomposition limits and resistivity requirements ofInternational Registered Alloy Designation 110.
Critical attention is paid to the enamel as the material utilised to insulate the conductor. Choice of enamelis a key factor and is linked both to the enamellingsystem as well as the electrical, mechanical andtechnical characteristics of the finished product.
The insulation enamels sourced by ATCO Industrialare supplied by internationally approved manufacturers specialising within this field. For all Tridonic ballasts insulation Class H+ ( 200 C ) is used.
Minimum stray fieldsTridonic ballasts are designed to keep stray fieldsat a minimum, thus enabling them to be used near sensitive equipment.
Consistent high qualityCertified to ISO 9001, the production process and equipment guarantee a consistent high qualitystandard. All finished goods are 100 % end of linetested and only the highest quality raw materialsare used. Consistent high quality is ensured bythe use of fully automatic production.
Special features of Tridonic ballasts: very short magnetic paths transverse lamination design with no stray field junctions compact windings low power consumption short heat paths maximum winding temperature tw = 130 C class H insulation fully automatic production with continuous tolerance test varnish impregnation 100 % final testing, including continuity, high voltage, winding short-circuit and operating values long service life
National and international test marksTridonic ballasts are approved by nationaland international test houses.
Magnetic ballasts for fluorescent lampsProduct information
-
Mag
netic
bal
last
s
www.tridonic.com 15Asia Pacific Catalogue 2011
Switch start circuitThe most widely used circuit. It is simple, economi-cal and one of the most efficient ways of operatinga fluorescent lamp. The starter can be of the glow switch type or electronic. By far the most commonis the glow starter. When the starter contacts open,the ballast supplies the starting voltage.
Advantages: simple wiring low temperature operation ( to -10 C ) economical
Disadvantages: flicker on start-up short delay in striking more than 1 wear part ( lamp and starter )
The operating sequence is as follows:1. When power is switched on, mains voltage appears across the contacts in the starter bottle, striking an arc between them.
2. The heat of the arc causes the bi-metal contact to bend and make contact with the other contact thereby extinguishing the arc and removing the heat source. The ballast and the lamp cathodes are now connected in series across the supply and the relatively heavypre-heat current flows, heating the lamp cathodes.
3. The starter contact cools down and re-opens.The sudden interruption of the pre-heat current causes a voltage spike to develop which ignites the lamp. Lamp voltage of less than half supply voltage is now insufficient to re-strike the arc in the starter bottle and the lamp remains alight.
Switch start circuits provide reliable starting in ambient temperatures -10 to +50 C.
FS2 type starters are used in single and twin lampcircuits up to and including 20 W.
FSU type starters are used in single lamp circuitsto 80 W. Note that 85 and 125 W lamps require very special starters.
Electronic starters are far more complex. They provide rapid start precision operation of the lamp.
Twin series circuitA circuit used for most lamps up to 20 W. Twofluorescent lamps are run in series on one ballastbut with individual starters operating per lamp.
Magnetic ballasts for fluorescent lampsProduct information
-
www.tridonic.com16 Asia Pacific Catalogue 2011
Fluorescent lamp ballast guide
Fluorescent lamps have combined the technologyand sophistication of fluorescent lighting with thecompact convenience of incandescent light fittings.
Tridonic offers a comprehensive range of standardEC energy control ballasts as well as LLEC low loss ballasts designed to operate compact fluorescent lamps from 5 through to 38 W.
Magnetic ballasts for fluorescent lampsProduct information
Lamp Code Wattage Length Cap Nominal current Standard ballast Low loss ballast
T5-Lamp FD-4 4 W 150 mm G5 170 mA EC 4/6/8 LLEC 4/6/816 mm FD-6 6 W 225 mm G5 160 mA EC 4/6/8 LLEC 4/6/8
FD-6 2 x 6 W 225 mm G5 160 mA EC 13 LLEC 13
FD-8 8 W 300 mm G5 145 mA EC 4/6/8 LLEC 4/6/8
FD-8 2 x 8 W 300 mm G5 145 mA EC 13 LLEC 13
FD-13 13 W 525 mm G5 165 mA EC 13 LLEC 13
T8-Lamp FD-10 10 W 330 mm G13 230 mA EC 10 LLEC 10
26 mm FD-15 15 W 450 mm G13 310 mA EC 15 LLEC 15
FD-15 2 x 15 W 450 mm G13 310 mA EC 30 LLEC 30
FD-18 18 W 600 mm G13 370 mA EC 18/20 LLEC 18/20
FD-18 2 x 18 W 600 mm G13 370 mA EC 36/40 LLEC 36/40
FD-30 30 W 900 mm G13 365 mA EC 30 LLEC 30
FD-36 36 W 1,200 mm G13 430 mA EC 36/40 LLEC 36/40
FD-58 58 W 1,500 mm G13 670 mA EC 58/65 LLEC 58/65
T12-Lamp FD-20 20 W 600 mm G13 370 mA EC 18/20 LLEC 18/20
38 mm FD-20 2 x 20 W 600 mm G13 370 mA EC 36/40 LLEC 36/40
FD-40 40 W 1,200 mm G13 430 mA EC 36/40 LLEC 36/40
FD-65 65 W 1,500 mm G13 670 mA EC 58/65 LLEC 58/65
T8-Circline FC-22 22 W 210 mm G10q 400 mA EC 22 LLEC 22
26 mm FC-32 32 W 305 mm G10q 450 mA EC 32 LLEC 32
FC-40 40 W 406 mm G10q 420 mA EC 36/40 LLEC 36/40
TC-S and TC-L FSD-5 5 W TC-S 2G7 / G23 180 mA EC 9 LLEC 9
FSD-5 2 x 5 W TC-S 2G7 / G23 180 mA EC 13 LLEC 13
FSD-7 7 W TC-S 2G7 / G23 175 mA EC 9 LLEC 9
FSD-7 2 x 7 W TC-S 2G7 / G23 175 mA EC 13 LLEC 13
FSD-9 9 W TC-S 2G7 / G23 170 mA EC 9 LLEC 9
FSD-9 2 x 9 W TC-S 2G7 / G23 170 mA EC 13 LLEC 13
FSD-11 11 W TC-S 2G7 / G23 155 mA EC 9 LLEC 9
FSD-18 18 W TC-L 2G11 375 mA EC 18/20 LLEC 18/20
FSD-18 2 x 18 W TC-L 2G11 375 mA EC 36/40 LLEC 36/40
FSD-24 24 W TC-L 2G11 345 mA EC 18/20 LLEC 18/20
FSD-36 36 W TC-L 2G11 435 mA EC 36/40 LLEC 36/40
TC-D FSQ-10 10 W TC-D G24q-1 190 mA EC 13 LLEC 13
FSQ-13 13 W TC-D G24q-1 175 mA EC 13 LLEC 13
FSQ-18 18 W TC-D G24q-1 220 mA EC 18H LLEC 18H
FSQ-26 26 W TC-D G24q-1 325 mA EC 18/20 LLEC 18/20
TC-T FSM-10 10 W TC-T GX24q-1 190 mA EC 13 LLEC 13
FSM-13 13 W TC-T GX24q-1 175 mA EC 13 LLEC 13
FSM-18 18 W TC-T GX24q-1 225 mA EC 18H LLEC 18H
FSM-26 26 W TC-T GX24q-1 325 mA EC 18/20 LLEC 18/20
TC-DD FSS-10 10 W TC-DD GR10q 180 mA EC 13 LLEC 13
2D-lamp FSS-16 16 W TC-DD GR10q 195 mA EC 16 LLEC 16
FSS-21 21 W TC-DD GR10q 260 mA EC 21 LLEC 21
FSS-28 28 W TC-DD GR10q 320 mA EC 18/20 LLEC 18/20
FSS-38 38 W TC-DD GR10q 430 mA EC 36/40 LLEC 36/40
TC-F flat FSS-18 18 W TC-F 2G10 375 mA EC 18/20 LLEC 18/20
FSS-18 2 x 18 W TC-F 2G10 375 mA EC 36/40 LLEC 36/40
FSS-24 24 W TC-F 2G10 345 mA EC 18/20 LLEC 18/20FSS-36 36 W TC-F 2G10 435 mA EC 36/40 LLEC 36/40
Asia Pacific catalogue 2007 29www.tridonicatco.com.au
Fluorescent lamp ballast guide
Fluorescent lamps have combined the technology and
sophistication of fluorescent lighting with the compact
convenience of incandescent light fittings.
TridonicAtco offers a comprehensive range of standard EC energy
control ballasts as well as LLEC low loss ballasts designed to
operate compact fluorescent lamps from 4 W through to 65 W.
Lamp Code Wattage Length Cap Nominal current Standard ballast Low loss ballastT5-Lamp FD-4 4 W 150 mm G5 170 mA EC 4/6/8 LLEC 4/6/8
16 mm FD-6 6 W 225 mm G5 160 mA EC 4/6/8 LLEC 4/6/8
FD-6 2 x 6 W 225 mm G5 160 mA EC 13 LLEC 13
FD-8 8 W 300 mm G5 145 mA EC 4/6/8 LLEC 4/6/8
FD-8 2 x 8 W 300 mm G5 145 mA EC 13 LLEC 13
FD-13 13 W 525 mm G5 165 mA EC 13 LLEC 13
T8-Lamp FD-10 10 W 330 mm G13 230 mA EC 10 LLEC 10
26 mm FD-15 15 W 450 mm G13 310 mA EC 15 LLEC 15
FD-15 2 x 15 W 450 mm G13 310 mA EC 30 LLEC 30
FD-18 18 W 600 mm G13 370 mA EC 18/20 LLEC 18/20
FD-18 2 x 18 W 600 mm G13 370 mA EC 36/40 LLEC 36/40
FD-30 30 W 900 mm G13 365 mA EC 30 LLEC 30
FD-36 36 W 1,200 mm G13 430 mA EC 36/40 LLEC 36/40
FD-58 58 W 1,500 mm G13 670 mA EC 58/65 LLEC 58/65
T12-Lamp FD-20 20 W 600 mm G13 370 mA EC 18/20 LLEC 18/20
38 mm FD-20 2 x 20 W 600 mm G13 370 mA EC 36/40 LLEC 36/40
FD-40 40 W 1,200 mm G13 430 mA EC 36/40 LLEC 36/40
FD-65 65 W 1,500 mm G13 670 mA EC 58/65 LLEC 58/65
T8-Circline FC-22 22 W 210 mm G10q 400 mA EC 22 LLEC 22
26 mm FC-32 32 W 305 mm G10q 450 mA EC 32 LLEC 32
FC-40 40 W 406 mm G10q 420 mA EC 36/40 LLEC 36/40
TC-S and TC-L FSD-5 5 W TC-S 2G7 / G23 180 mA EC 9 LLEC 9
FSD-5 2 x 5 W TC-S 2G7 / G23 180 mA EC 13 LLEC 13
FSD-7 7 W TC-S 2G7 / G23 175 mA EC 9 LLEC 9
FSD-7 2 x 7 W TC-S 2G7 / G23 175 mA EC 13 LLEC 13
FSD-9 9 W TC-S 2G7 / G23 170 mA EC 9 LLEC 9
FSD-9 2 x 9 W TC-S 2G7 / G23 170 mA EC 13 LLEC 13
FSD-11 11 W TC-S 2G7 / G23 155 mA EC 9 LLEC 9
FSD-18 18 W TC-L 2G11 375 mA EC 18/20 LLEC 18/20
FSD-18 2 x 18 W TC-L 2G11 375 mA EC 36/40 LLEC 36/40
FSD-24 24 W TC-L 2G11 345 mA EC 18/20 LLEC 18/20
FSD-36 36 W TC-L 2G11 435 mA EC 36/40 LLEC 36/40
TC-D FSQ-10 10 W TC-D G24q-1 190 mA EC 13 LLEC 13
FSQ-13 13 W TC-D G24q-1 175 mA EC 13 LLEC 13
FSQ-18 18 W TC-D G24q-1 220 mA EC 18H LLEC 18H
FSQ-26 26 W TC-D G24q-1 325 mA EC 18/20 LLEC 18/20
TC-T FSM-10 10 W TC-T GX24q-1 190 mA EC 13 LLEC 13
FSM-13 13 W TC-T GX24q-1 175 mA EC 13 LLEC 13
FSM-18 18 W TC-T GX24q-1 225 mA EC 18H LLEC 18H
FSM-26 26 W TC-T GX24q-1 325 mA EC 18/20 LLEC 18/20
TC-DD FSS-10 10 W TC-DD GR10q 180 mA EC 13 LLEC 13
2D-lamp FSS-16 16 W TC-DD GR10q 195 mA EC 16 LLEC 16
FSS-21 21 W TC-DD GR10q 260 mA EC 21 LLEC 21
FSS-28 28 W TC-DD GR10q 320 mA EC 18/20 LLEC 18/20
FSS-38 38 W TC-DD GR10q 430 mA EC 36/40 LLEC 36/40
TC-F flat FSS-18 18 W TC-F 2G10 375 mA EC 18/20 LLEC 18/20
FSS-18 2 x 18 W TC-F 2G10 375 mA EC 36/40 LLEC 36/40
FSS-24 24 W TC-F 2G10 345 mA EC 18/20 LLEC 18/20
FSS-36 36 W TC-F 2G10 435 mA EC 36/40 LLEC 36/40
Asia Pacific catalogue 2007 29www.tridonicatco.com.au
Fluorescent lamp ballast guide
Fluorescent lamps have combined the technology and
sophistication of fluorescent lighting with the compact
convenience of incandescent light fittings.
TridonicAtco offers a comprehensive range of standard EC energy
control ballasts as well as LLEC low loss ballasts designed to
operate compact fluorescent lamps from 4 W through to 65 W.
Lamp Code Wattage Length Cap Nominal current Standard ballast Low loss ballastT5-Lamp FD-4 4 W 150 mm G5 170 mA EC 4/6/8 LLEC 4/6/8
16 mm FD-6 6 W 225 mm G5 160 mA EC 4/6/8 LLEC 4/6/8
FD-6 2 x 6 W 225 mm G5 160 mA EC 13 LLEC 13
FD-8 8 W 300 mm G5 145 mA EC 4/6/8 LLEC 4/6/8
FD-8 2 x 8 W 300 mm G5 145 mA EC 13 LLEC 13
FD-13 13 W 525 mm G5 165 mA EC 13 LLEC 13
T8-Lamp FD-10 10 W 330 mm G13 230 mA EC 10 LLEC 10
26 mm FD-15 15 W 450 mm G13 310 mA EC 15 LLEC 15
FD-15 2 x 15 W 450 mm G13 310 mA EC 30 LLEC 30
FD-18 18 W 600 mm G13 370 mA EC 18/20 LLEC 18/20
FD-18 2 x 18 W 600 mm G13 370 mA EC 36/40 LLEC 36/40
FD-30 30 W 900 mm G13 365 mA EC 30 LLEC 30
FD-36 36 W 1,200 mm G13 430 mA EC 36/40 LLEC 36/40
FD-58 58 W 1,500 mm G13 670 mA EC 58/65 LLEC 58/65
T12-Lamp FD-20 20 W 600 mm G13 370 mA EC 18/20 LLEC 18/20
38 mm FD-20 2 x 20 W 600 mm G13 370 mA EC 36/40 LLEC 36/40
FD-40 40 W 1,200 mm G13 430 mA EC 36/40 LLEC 36/40
FD-65 65 W 1,500 mm G13 670 mA EC 58/65 LLEC 58/65
T8-Circline FC-22 22 W 210 mm G10q 400 mA EC 22 LLEC 22
26 mm FC-32 32 W 305 mm G10q 450 mA EC 32 LLEC 32
FC-40 40 W 406 mm G10q 420 mA EC 36/40 LLEC 36/40
TC-S and TC-L FSD-5 5 W TC-S 2G7 / G23 180 mA EC 9 LLEC 9
FSD-5 2 x 5 W TC-S 2G7 / G23 180 mA EC 13 LLEC 13
FSD-7 7 W TC-S 2G7 / G23 175 mA EC 9 LLEC 9
FSD-7 2 x 7 W TC-S 2G7 / G23 175 mA EC 13 LLEC 13
FSD-9 9 W TC-S 2G7 / G23 170 mA EC 9 LLEC 9
FSD-9 2 x 9 W TC-S 2G7 / G23 170 mA EC 13 LLEC 13
FSD-11 11 W TC-S 2G7 / G23 155 mA EC 9 LLEC 9
FSD-18 18 W TC-L 2G11 375 mA EC 18/20 LLEC 18/20
FSD-18 2 x 18 W TC-L 2G11 375 mA EC 36/40 LLEC 36/40
FSD-24 24 W TC-L 2G11 345 mA EC 18/20 LLEC 18/20
FSD-36 36 W TC-L 2G11 435 mA EC 36/40 LLEC 36/40
TC-D FSQ-10 10 W TC-D G24q-1 190 mA EC 13 LLEC 13
FSQ-13 13 W TC-D G24q-1 175 mA EC 13 LLEC 13
FSQ-18 18 W TC-D G24q-1 220 mA EC 18H LLEC 18H
FSQ-26 26 W TC-D G24q-1 325 mA EC 18/20 LLEC 18/20
TC-T FSM-10 10 W TC-T GX24q-1 190 mA EC 13 LLEC 13
FSM-13 13 W TC-T GX24q-1 175 mA EC 13 LLEC 13
FSM-18 18 W TC-T GX24q-1 225 mA EC 18H LLEC 18H
FSM-26 26 W TC-T GX24q-1 325 mA EC 18/20 LLEC 18/20
TC-DD FSS-10 10 W TC-DD GR10q 180 mA EC 13 LLEC 13
2D-lamp FSS-16 16 W TC-DD GR10q 195 mA EC 16 LLEC 16
FSS-21 21 W TC-DD GR10q 260 mA EC 21 LLEC 21
FSS-28 28 W TC-DD GR10q 320 mA EC 18/20 LLEC 18/20
FSS-38 38 W TC-DD GR10q 430 mA EC 36/40 LLEC 36/40
TC-F flat FSS-18 18 W TC-F 2G10 375 mA EC 18/20 LLEC 18/20
FSS-18 2 x 18 W TC-F 2G10 375 mA EC 36/40 LLEC 36/40
FSS-24 24 W TC-F 2G10 345 mA EC 18/20 LLEC 18/20
FSS-36 36 W TC-F 2G10 435 mA EC 36/40 LLEC 36/40
Asia Pacific catalogue 2007 29www.tridonicatco.com.au
Fluorescent lamp ballast guide
Fluorescent lamps have combined the technology and
sophistication of fluorescent lighting with the compact
convenience of incandescent light fittings.
TridonicAtco offers a comprehensive range of standard EC energy
control ballasts as well as LLEC low loss ballasts designed to
operate compact fluorescent lamps from 4 W through to 65 W.
Lamp Code Wattage Length Cap Nominal current Standard ballast Low loss ballastT5-Lamp FD-4 4 W 150 mm G5 170 mA EC 4/6/8 LLEC 4/6/8
16 mm FD-6 6 W 225 mm G5 160 mA EC 4/6/8 LLEC 4/6/8
FD-6 2 x 6 W 225 mm G5 160 mA EC 13 LLEC 13
FD-8 8 W 300 mm G5 145 mA EC 4/6/8 LLEC 4/6/8
FD-8 2 x 8 W 300 mm G5 145 mA EC 13 LLEC 13
FD-13 13 W 525 mm G5 165 mA EC 13 LLEC 13
T8-Lamp FD-10 10 W 330 mm G13 230 mA EC 10 LLEC 10
26 mm FD-15 15 W 450 mm G13 310 mA EC 15 LLEC 15
FD-15 2 x 15 W 450 mm G13 310 mA EC 30 LLEC 30
FD-18 18 W 600 mm G13 370 mA EC 18/20 LLEC 18/20
FD-18 2 x 18 W 600 mm G13 370 mA EC 36/40 LLEC 36/40
FD-30 30 W 900 mm G13 365 mA EC 30 LLEC 30
FD-36 36 W 1,200 mm G13 430 mA EC 36/40 LLEC 36/40
FD-58 58 W 1,500 mm G13 670 mA EC 58/65 LLEC 58/65
T12-Lamp FD-20 20 W 600 mm G13 370 mA EC 18/20 LLEC 18/20
38 mm FD-20 2 x 20 W 600 mm G13 370 mA EC 36/40 LLEC 36/40
FD-40 40 W 1,200 mm G13 430 mA EC 36/40 LLEC 36/40
FD-65 65 W 1,500 mm G13 670 mA EC 58/65 LLEC 58/65
T8-Circline FC-22 22 W 210 mm G10q 400 mA EC 22 LLEC 22
26 mm FC-32 32 W 305 mm G10q 450 mA EC 32 LLEC 32
FC-40 40 W 406 mm G10q 420 mA EC 36/40 LLEC 36/40
TC-S and TC-L FSD-5 5 W TC-S 2G7 / G23 180 mA EC 9 LLEC 9
FSD-5 2 x 5 W TC-S 2G7 / G23 180 mA EC 13 LLEC 13
FSD-7 7 W TC-S 2G7 / G23 175 mA EC 9 LLEC 9
FSD-7 2 x 7 W TC-S 2G7 / G23 175 mA EC 13 LLEC 13
FSD-9 9 W TC-S 2G7 / G23 170 mA EC 9 LLEC 9
FSD-9 2 x 9 W TC-S 2G7 / G23 170 mA EC 13 LLEC 13
FSD-11 11 W TC-S 2G7 / G23 155 mA EC 9 LLEC 9
FSD-18 18 W TC-L 2G11 375 mA EC 18/20 LLEC 18/20
FSD-18 2 x 18 W TC-L 2G11 375 mA EC 36/40 LLEC 36/40
FSD-24 24 W TC-L 2G11 345 mA EC 18/20 LLEC 18/20
FSD-36 36 W TC-L 2G11 435 mA EC 36/40 LLEC 36/40
TC-D FSQ-10 10 W TC-D G24q-1 190 mA EC 13 LLEC 13
FSQ-13 13 W TC-D G24q-1 175 mA EC 13 LLEC 13
FSQ-18 18 W TC-D G24q-1 220 mA EC 18H LLEC 18H
FSQ-26 26 W TC-D G24q-1 325 mA EC 18/20 LLEC 18/20
TC-T FSM-10 10 W TC-T GX24q-1 190 mA EC 13 LLEC 13
FSM-13 13 W TC-T GX24q-1 175 mA EC 13 LLEC 13
FSM-18 18 W TC-T GX24q-1 225 mA EC 18H LLEC 18H
FSM-26 26 W TC-T GX24q-1 325 mA EC 18/20 LLEC 18/20
TC-DD FSS-10 10 W TC-DD GR10q 180 mA EC 13 LLEC 13
2D-lamp FSS-16 16 W TC-DD GR10q 195 mA EC 16 LLEC 16
FSS-21 21 W TC-DD GR10q 260 mA EC 21 LLEC 21
FSS-28 28 W TC-DD GR10q 320 mA EC 18/20 LLEC 18/20
FSS-38 38 W TC-DD GR10q 430 mA EC 36/40 LLEC 36/40
TC-F flat FSS-18 18 W TC-F 2G10 375 mA EC 18/20 LLEC 18/20
FSS-18 2 x 18 W TC-F 2G10 375 mA EC 36/40 LLEC 36/40
FSS-24 24 W TC-F 2G10 345 mA EC 18/20 LLEC 18/20
FSS-36 36 W TC-F 2G10 435 mA EC 36/40 LLEC 36/40
Asia Pacific catalogue 2007 29www.tridonicatco.com.au
Fluorescent lamp ballast guide
Fluorescent lamps have combined the technology and
sophistication of fluorescent lighting with the compact
convenience of incandescent light fittings.
TridonicAtco offers a comprehensive range of standard EC energy
control ballasts as well as LLEC low loss ballasts designed to
operate compact fluorescent lamps from 4 W through to 65 W.
Lamp Code Wattage Length Cap Nominal current Standard ballast Low loss ballastT5-Lamp FD-4 4 W 150 mm G5 170 mA EC 4/6/8 LLEC 4/6/8
16 mm FD-6 6 W 225 mm G5 160 mA EC 4/6/8 LLEC 4/6/8
FD-6 2 x 6 W 225 mm G5 160 mA EC 13 LLEC 13
FD-8 8 W 300 mm G5 145 mA EC 4/6/8 LLEC 4/6/8
FD-8 2 x 8 W 300 mm G5 145 mA EC 13 LLEC 13
FD-13 13 W 525 mm G5 165 mA EC 13 LLEC 13
T8-Lamp FD-10 10 W 330 mm G13 230 mA EC 10 LLEC 10
26 mm FD-15 15 W 450 mm G13 310 mA EC 15 LLEC 15
FD-15 2 x 15 W 450 mm G13 310 mA EC 30 LLEC 30
FD-18 18 W 600 mm G13 370 mA EC 18/20 LLEC 18/20
FD-18 2 x 18 W 600 mm G13 370 mA EC 36/40 LLEC 36/40
FD-30 30 W 900 mm G13 365 mA EC 30 LLEC 30
FD-36 36 W 1,200 mm G13 430 mA EC 36/40 LLEC 36/40
FD-58 58 W 1,500 mm G13 670 mA EC 58/65 LLEC 58/65
T12-Lamp FD-20 20 W 600 mm G13 370 mA EC 18/20 LLEC 18/20
38 mm FD-20 2 x 20 W 600 mm G13 370 mA EC 36/40 LLEC 36/40
FD-40 40 W 1,200 mm G13 430 mA EC 36/40 LLEC 36/40
FD-65 65 W 1,500 mm G13 670 mA EC 58/65 LLEC 58/65
T8-Circline FC-22 22 W 210 mm G10q 400 mA EC 22 LLEC 22
26 mm FC-32 32 W 305 mm G10q 450 mA EC 32 LLEC 32
FC-40 40 W 406 mm G10q 420 mA EC 36/40 LLEC 36/40
TC-S and TC-L FSD-5 5 W TC-S 2G7 / G23 180 mA EC 9 LLEC 9
FSD-5 2 x 5 W TC-S 2G7 / G23 180 mA EC 13 LLEC 13
FSD-7 7 W TC-S 2G7 / G23 175 mA EC 9 LLEC 9
FSD-7 2 x 7 W TC-S 2G7 / G23 175 mA EC 13 LLEC 13
FSD-9 9 W TC-S 2G7 / G23 170 mA EC 9 LLEC 9
FSD-9 2 x 9 W TC-S 2G7 / G23 170 mA EC 13 LLEC 13
FSD-11 11 W TC-S 2G7 / G23 155 mA EC 9 LLEC 9
FSD-18 18 W TC-L 2G11 375 mA EC 18/20 LLEC 18/20
FSD-18 2 x 18 W TC-L 2G11 375 mA EC 36/40 LLEC 36/40
FSD-24 24 W TC-L 2G11 345 mA EC 18/20 LLEC 18/20
FSD-36 36 W TC-L 2G11 435 mA EC 36/40 LLEC 36/40
TC-D FSQ-10 10 W TC-D G24q-1 190 mA EC 13 LLEC 13
FSQ-13 13 W TC-D G24q-1 175 mA EC 13 LLEC 13
FSQ-18 18 W TC-D G24q-1 220 mA EC 18H LLEC 18H
FSQ-26 26 W TC-D G24q-1 325 mA EC 18/20 LLEC 18/20
TC-T FSM-10 10 W TC-T GX24q-1 190 mA EC 13 LLEC 13
FSM-13 13 W TC-T GX24q-1 175 mA EC 13 LLEC 13
FSM-18 18 W TC-T GX24q-1 225 mA EC 18H LLEC 18H
FSM-26 26 W TC-T GX24q-1 325 mA EC 18/20 LLEC 18/20
TC-DD FSS-10 10 W TC-DD GR10q 180 mA EC 13 LLEC 13
2D-lamp FSS-16 16 W TC-DD GR10q 195 mA EC 16 LLEC 16
FSS-21 21 W TC-DD GR10q 260 mA EC 21 LLEC 21
FSS-28 28 W TC-DD GR10q 320 mA EC 18/20 LLEC 18/20
FSS-38 38 W TC-DD GR10q 430 mA EC 36/40 LLEC 36/40
TC-F flat FSS-18 18 W TC-F 2G10 375 mA EC 18/20 LLEC 18/20
FSS-18 2 x 18 W TC-F 2G10 375 mA EC 36/40 LLEC 36/40
FSS-24 24 W TC-F 2G10 345 mA EC 18/20 LLEC 18/20
FSS-36 36 W TC-F 2G10 435 mA EC 36/40 LLEC 36/40
Asia Pacific catalogue 2007 29www.tridonicatco.com.au
Fluorescent lamp ballast guide
Fluorescent lamps have combined the technology and
sophistication of fluorescent lighting with the compact
convenience of incandescent light fittings.
TridonicAtco offers a comprehensive range of standard EC energy
control ballasts as well as LLEC low loss ballasts designed to
operate compact fluorescent lamps from 4 W through to 65 W.
Lamp Code Wattage Length Cap Nominal current Standard ballast Low loss ballastT5-Lamp FD-4 4 W 150 mm G5 170 mA EC 4/6/8 LLEC 4/6/8
16 mm FD-6 6 W 225 mm G5 160 mA EC 4/6/8 LLEC 4/6/8
FD-6 2 x 6 W 225 mm G5 160 mA EC 13 LLEC 13
FD-8 8 W 300 mm G5 145 mA EC 4/6/8 LLEC 4/6/8
FD-8 2 x 8 W 300 mm G5 145 mA EC 13 LLEC 13
FD-13 13 W 525 mm G5 165 mA EC 13 LLEC 13
T8-Lamp FD-10 10 W 330 mm G13 230 mA EC 10 LLEC 10
26 mm FD-15 15 W 450 mm G13 310 mA EC 15 LLEC 15
FD-15 2 x 15 W 450 mm G13 310 mA EC 30 LLEC 30
FD-18 18 W 600 mm G13 370 mA EC 18/20 LLEC 18/20
FD-18 2 x 18 W 600 mm G13 370 mA EC 36/40 LLEC 36/40
FD-30 30 W 900 mm G13 365 mA EC 30 LLEC 30
FD-36 36 W 1,200 mm G13 430 mA EC 36/40 LLEC 36/40
FD-58 58 W 1,500 mm G13 670 mA EC 58/65 LLEC 58/65
T12-Lamp FD-20 20 W 600 mm G13 370 mA EC 18/20 LLEC 18/20
38 mm FD-20 2 x 20 W 600 mm G13 370 mA EC 36/40 LLEC 36/40
FD-40 40 W 1,200 mm G13 430 mA EC 36/40 LLEC 36/40
FD-65 65 W 1,500 mm G13 670 mA EC 58/65 LLEC 58/65
T8-Circline FC-22 22 W 210 mm G10q 400 mA EC 22 LLEC 22
26 mm FC-32 32 W 305 mm G10q 450 mA EC 32 LLEC 32
FC-40 40 W 406 mm G10q 420 mA EC 36/40 LLEC 36/40
TC-S and TC-L FSD-5 5 W TC-S 2G7 / G23 180 mA EC 9 LLEC 9
FSD-5 2 x 5 W TC-S 2G7 / G23 180 mA EC 13 LLEC 13
FSD-7 7 W TC-S 2G7 / G23 175 mA EC 9 LLEC 9
FSD-7 2 x 7 W TC-S 2G7 / G23 175 mA EC 13 LLEC 13
FSD-9 9 W TC-S 2G7 / G23 170 mA EC 9 LLEC 9
FSD-9 2 x 9 W TC-S 2G7 / G23 170 mA EC 13 LLEC 13
FSD-11 11 W TC-S 2G7 / G23 155 mA EC 9 LLEC 9
FSD-18 18 W TC-L 2G11 375 mA EC 18/20 LLEC 18/20
FSD-18 2 x 18 W TC-L 2G11 375 mA EC 36/40 LLEC 36/40
FSD-24 24 W TC-L 2G11 345 mA EC 18/20 LLEC 18/20
FSD-36 36 W TC-L 2G11 435 mA EC 36/40 LLEC 36/40
TC-D FSQ-10 10 W TC-D G24q-1 190 mA EC 13 LLEC 13
FSQ-13 13 W TC-D G24q-1 175 mA EC 13 LLEC 13
FSQ-18 18 W TC-D G24q-1 220 mA EC 18H LLEC 18H
FSQ-26 26 W TC-D G24q-1 325 mA EC 18/20 LLEC 18/20
TC-T FSM-10 10 W TC-T GX24q-1 190 mA EC 13 LLEC 13
FSM-13 13 W TC-T GX24q-1 175 mA EC 13 LLEC 13
FSM-18 18 W TC-T GX24q-1 225 mA EC 18H LLEC 18H
FSM-26 26 W TC-T GX24q-1 325 mA EC 18/20 LLEC 18/20
TC-DD FSS-10 10 W TC-DD GR10q 180 mA EC 13 LLEC 13
2D-lamp FSS-16 16 W TC-DD GR10q 195 mA EC 16 LLEC 16
FSS-21 21 W TC-DD GR10q 260 mA EC 21 LLEC 21
FSS-28 28 W TC-DD GR10q 320 mA EC 18/20 LLEC 18/20
FSS-38 38 W TC-DD GR10q 430 mA EC 36/40 LLEC 36/40
TC-F flat FSS-18 18 W TC-F 2G10 375 mA EC 18/20 LLEC 18/20
FSS-18 2 x 18 W TC-F 2G10 375 mA EC 36/40 LLEC 36/40
FSS-24 24 W TC-F 2G10 345 mA EC 18/20 LLEC 18/20
FSS-36 36 W TC-F 2G10 435 mA EC 36/40 LLEC 36/40
Asia Pacific catalogue 2007 29www.tridonicatco.com.au
Fluorescent lamp ballast guide
Fluorescent lamps have combined the technology and
sophistication of fluorescent lighting with the compact
convenience of incandescent light fittings.
TridonicAtco offers a comprehensive range of standard EC energy
control ballasts as well as LLEC low loss ballasts designed to
operate compact fluorescent lamps from 4 W through to 65 W.
Lamp Code Wattage Length Cap Nominal current Standard ballast Low loss ballastT5-Lamp FD-4 4 W 150 mm G5 170 mA EC 4/6/8 LLEC 4/6/8
16 mm FD-6 6 W 225 mm G5 160 mA EC 4/6/8 LLEC 4/6/8
FD-6 2 x 6 W 225 mm G5 160 mA EC 13 LLEC 13
FD-8 8 W 300 mm G5 145 mA EC 4/6/8 LLEC 4/6/8
FD-8 2 x 8 W 300 mm G5 145 mA EC 13 LLEC 13
FD-13 13 W 525 mm G5 165 mA EC 13 LLEC 13
T8-Lamp FD-10 10 W 330 mm G13 230 mA EC 10 LLEC 10
26 mm FD-15 15 W 450 mm G13 310 mA EC 15 LLEC 15
FD-15 2 x 15 W 450 mm G13 310 mA EC 30 LLEC 30
FD-18 18 W 600 mm G13 370 mA EC 18/20 LLEC 18/20
FD-18 2 x 18 W 600 mm G13 370 mA EC 36/40 LLEC 36/40
FD-30 30 W 900 mm G13 365 mA EC 30 LLEC 30
FD-36 36 W 1,200 mm G13 430 mA EC 36/40 LLEC 36/40
FD-58 58 W 1,500 mm G13 670 mA EC 58/65 LLEC 58/65
T12-Lamp FD-20 20 W 600 mm G13 370 mA EC 18/20 LLEC 18/20
38 mm FD-20 2 x 20 W 600 mm G13 370 mA EC 36/40 LLEC 36/40
FD-40 40 W 1,200 mm G13 430 mA EC 36/40 LLEC 36/40
FD-65 65 W 1,500 mm G13 670 mA EC 58/65 LLEC 58/65
T8-Circline FC-22 22 W 210 mm G10q 400 mA EC 22 LLEC 22
26 mm FC-32 32 W 305 mm G10q 450 mA EC 32 LLEC 32
FC-40 40 W 406 mm G10q 420 mA EC 36/40 LLEC 36/40
TC-S and TC-L FSD-5 5 W TC-S 2G7 / G23 180 mA EC 9 LLEC 9
FSD-5 2 x 5 W TC-S 2G7 / G23 180 mA EC 13 LLEC 13
FSD-7 7 W TC-S 2G7 / G23 175 mA EC 9 LLEC 9
FSD-7 2 x 7 W TC-S 2G7 / G23 175 mA EC 13 LLEC 13
FSD-9 9 W TC-S 2G7 / G23 170 mA EC 9 LLEC 9
FSD-9 2 x 9 W TC-S 2G7 / G23 170 mA EC 13 LLEC 13
FSD-11 11 W TC-S 2G7 / G23 155 mA EC 9 LLEC 9
FSD-18 18 W TC-L 2G11 375 mA EC 18/20 LLEC 18/20
FSD-18 2 x 18 W TC-L 2G11 375 mA EC 36/40 LLEC 36/40
FSD-24 24 W TC-L 2G11 345 mA EC 18/20 LLEC 18/20
FSD-36 36 W TC-L 2G11 435 mA EC 36/40 LLEC 36/40
TC-D FSQ-10 10 W TC-D G24q-1 190 mA EC 13 LLEC 13
FSQ-13 13 W TC-D G24q-1 175 mA EC 13 LLEC 13
FSQ-18 18 W TC-D G24q-1 220 mA EC 18H LLEC 18H
FSQ-26 26 W TC-D G24q-1 325 mA EC 18/20 LLEC 18/20
TC-T FSM-10 10 W TC-T GX24q-1 190 mA EC 13 LLEC 13
FSM-13 13 W TC-T GX24q-1 175 mA EC 13 LLEC 13
FSM-18 18 W TC-T GX24q-1 225 mA EC 18H LLEC 18H
FSM-26 26 W TC-T GX24q-1 325 mA EC 18/20 LLEC 18/20
TC-DD FSS-10 10 W TC-DD GR10q 180 mA EC 13 LLEC 13
2D-lamp FSS-16 16 W TC-DD GR10q 195 mA EC 16 LLEC 16
FSS-21 21 W TC-DD GR10q 260 mA EC 21 LLEC 21
FSS-28 28 W TC-DD GR10q 320 mA EC 18/20 LLEC 18/20
FSS-38 38 W TC-DD GR10q 430 mA EC 36/40 LLEC 36/40
TC-F flat FSS-18 18 W TC-F 2G10 375 mA EC 18/20 LLEC 18/20
FSS-18 2 x 18 W TC-F 2G10 375 mA EC 36/40 LLEC 36/40
FSS-24 24 W TC-F 2G10 345 mA EC 18/20 LLEC 18/20
FSS-36 36 W TC-F 2G10 435 mA EC 36/40 LLEC 36/40
Asia Pacific catalogue 2007 29www.tridonicatco.com.au
Fluorescent lamp ballast guide
Fluorescent lamps have combined the technology and
sophistication of fluorescent lighting with the compact
convenience of incandescent light fittings.
TridonicAtco offers a comprehensive range of standard EC energy
control ballasts as well as LLEC low loss ballasts designed to
operate compact fluorescent lamps from 4 W through to 65 W.
Lamp Code Wattage Length Cap Nominal current Standard ballast Low loss ballastT5-Lamp FD-4 4 W 150 mm G5 170 mA EC 4/6/8 LLEC 4/6/8
16 mm FD-6 6 W 225 mm G5 160 mA EC 4/6/8 LLEC 4/6/8
FD-6 2 x 6 W 225 mm G5 160 mA EC 13 LLEC 13
FD-8 8 W 300 mm G5 145 mA EC 4/6/8 LLEC 4/6/8
FD-8 2 x 8 W 300 mm G5 145 mA EC 13 LLEC 13
FD-13 13 W 525 mm G5 165 mA EC 13 LLEC 13
T8-Lamp FD-10 10 W 330 mm G13 230 mA EC 10 LLEC 10
26 mm FD-15 15 W 450 mm G13 310 mA EC 15 LLEC 15
FD-15 2 x 15 W 450 mm G13 310 mA EC 30 LLEC 30
FD-18 18 W 600 mm G13 370 mA EC 18/20 LLEC 18/20
FD-18 2 x 18 W 600 mm G13 370 mA EC 36/40 LLEC 36/40
FD-30 30 W 900 mm G13 365 mA EC 30 LLEC 30
FD-36 36 W 1,200 mm G13 430 mA EC 36/40 LLEC 36/40
FD-58 58 W 1,500 mm G13 670 mA EC 58/65 LLEC 58/65
T12-Lamp FD-20 20 W 600 mm G13 370 mA EC 18/20 LLEC 18/20
38 mm FD-20 2 x 20 W 600 mm G13 370 mA EC 36/40 LLEC 36/40
FD-40 40 W 1,200 mm G13 430 mA EC 36/40 LLEC 36/40
FD-65 65 W 1,500 mm G13 670 mA EC 58/65 LLEC 58/65
T8-Circline FC-22 22 W 210 mm G10q 400 mA EC 22 LLEC 22
26 mm FC-32 32 W 305 mm G10q 450 mA EC 32 LLEC 32
FC-40 40 W 406 mm G10q 420 mA EC 36/40 LLEC 36/40
TC-S and TC-L FSD-5 5 W TC-S 2G7 / G23 180 mA EC 9 LLEC 9
FSD-5 2 x 5 W TC-S 2G7 / G23 180 mA EC 13 LLEC 13
FSD-7 7 W TC-S 2G7 / G23 175 mA EC 9 LLEC 9
FSD-7 2 x 7 W TC-S 2G7 / G23 175 mA EC 13 LLEC 13
FSD-9 9 W TC-S 2G7 / G23 170 mA EC 9 LLEC 9
FSD-9 2 x 9 W TC-S 2G7 / G23 170 mA EC 13 LLEC 13
FSD-11 11 W TC-S 2G7 / G23 155 mA EC 9 LLEC 9
FSD-18 18 W TC-L 2G11 375 mA EC 18/20 LLEC 18/20
FSD-18 2 x 18 W TC-L 2G11 375 mA EC 36/40 LLEC 36/40
FSD-24 24 W TC-L 2G11 345 mA EC 18/20 LLEC 18/20
FSD-36 36 W TC-L 2G11 435 mA EC 36/40 LLEC 36/40
TC-D FSQ-10 10 W TC-D G24q-1 190 mA EC 13 LLEC 13
FSQ-13 13 W TC-D G24q-1 175 mA EC 13 LLEC 13
FSQ-18 18 W TC-D G24q-1 220 mA EC 18H LLEC 18H
FSQ-26 26 W TC-D G24q-1 325 mA EC 18/20 LLEC 18/20
TC-T FSM-10 10 W TC-T GX24q-1 190 mA EC 13 LLEC 13
FSM-13 13 W TC-T GX24q-1 175 mA EC 13 LLEC 13
FSM-18 18 W TC-T GX24q-1 225 mA EC 18H LLEC 18H
FSM-26 26 W TC-T GX24q-1 325 mA EC 18/20 LLEC 18/20
TC-DD FSS-10 10 W TC-DD GR10q 180 mA EC 13 LLEC 13
2D-lamp FSS-16 16 W TC-DD GR10q 195 mA EC 16 LLEC 16
FSS-21 21 W TC-DD GR10q 260 mA EC 21 LLEC 21
FSS-28 28 W TC-DD GR10q 320 mA EC 18/20 LLEC 18/20
FSS-38 38 W TC-DD GR10q 430 mA EC 36/40 LLEC 36/40
TC-F flat FSS-18 18 W TC-F 2G10 375 mA EC 18/20 LLEC 18/20
FSS-18 2 x 18 W TC-F 2G10 375 mA EC 36/40 LLEC 36/40
FSS-24 24 W TC-F 2G10 345 mA EC 18/20 LLEC 18/20
FSS-36 36 W TC-F 2G10 435 mA EC 36/40 LLEC 36/40
Asia Pacific catalogue 2007 29www.tridonicatco.com.au
Fluorescent lamp ballast guide
Fluorescent lamps have combined the technology and
sophistication of fluorescent lighting with the compact
convenience of incandescent light fittings.
TridonicAtco offers a comprehensive range of standard EC energy
control ballasts as well as LLEC low loss ballasts designed to
operate compact fluorescent lamps from 4 W through to 65 W.
Lamp Code Wattage Length Cap Nominal current Standard ballast Low loss ballastT5-Lamp FD-4 4 W 150 mm G5 170 mA EC 4/6/8 LLEC 4/6/8
16 mm FD-6 6 W 225 mm G5 160 mA EC 4/6/8 LLEC 4/6/8
FD-6 2 x 6 W 225 mm G5 160 mA EC 13 LLEC 13
FD-8 8 W 300 mm G5 145 mA EC 4/6/8 LLEC 4/6/8
FD-8 2 x 8 W 300 mm G5 145 mA EC 13 LLEC 13
FD-13 13 W 525 mm G5 165 mA EC 13 LLEC 13
T8-Lamp FD-10 10 W 330 mm G13 230 mA EC 10 LLEC 10
26 mm FD-15 15 W 450 mm G13 310 mA EC 15 LLEC 15
FD-15 2 x 15 W 450 mm G13 310 mA EC 30 LLEC 30
FD-18 18 W 600 mm G13 370 mA EC 18/20 LLEC 18/20
FD-18 2 x 18 W 600 mm G13 370 mA EC 36/40 LLEC 36/40
FD-30 30 W 900 mm G13 365 mA EC 30 LLEC 30
FD-36 36 W 1,200 mm G13 430 mA EC 36/40 LLEC 36/40
FD-58 58 W 1,500 mm G13 670 mA EC 58/65 LLEC 58/65
T12-Lamp FD-20 20 W 600 mm G13 370 mA EC 18/20 LLEC 18/20
38 mm FD-20 2 x 20 W 600 mm G13 370 mA EC 36/40 LLEC 36/40
FD-40 40 W 1,200 mm G13 430 mA EC 36/40 LLEC 36/40
FD-65 65 W 1,500 mm G13 670 mA EC 58/65 LLEC 58/65
T8-Circline FC-22 22 W 210 mm G10q 400 mA EC 22 LLEC 22
26 mm FC-32 32 W 305 mm G10q 450 mA EC 32 LLEC 32
FC-40 40 W 406 mm G10q 420 mA EC 36/40 LLEC 36/40
TC-S and TC-L FSD-5 5 W TC-S 2G7 / G23 180 mA EC 9 LLEC 9
FSD-5 2 x 5 W TC-S 2G7 / G23 180 mA EC 13 LLEC 13
FSD-7 7 W TC-S 2G7 / G23 175 mA EC 9 LLEC 9
FSD-7 2 x 7 W TC-S 2G7 / G23 175 mA EC 13 LLEC 13
FSD-9 9 W TC-S 2G7 / G23 170 mA EC 9 LLEC 9
FSD-9 2 x 9 W TC-S 2G7 / G23 170 mA EC 13 LLEC 13
FSD-11 11 W TC-S 2G7 / G23 155 mA EC 9 LLEC 9
FSD-18 18 W TC-L 2G11 375 mA EC 18/20 LLEC 18/20
FSD-18 2 x 18 W TC-L 2G11 375 mA EC 36/40 LLEC 36/40
FSD-24 24 W TC-L 2G11 345 mA EC 18/20 LLEC 18/20
FSD-36 36 W TC-L 2G11 435 mA EC 36/40 LLEC 36/40
TC-D FSQ-10 10 W TC-D G24q-1 190 mA EC 13 LLEC 13
FSQ-13 13 W TC-D G24q-1 175 mA EC 13 LLEC 13
FSQ-18 18 W TC-D G24q-1 220 mA EC 18H LLEC 18H
FSQ-26 26 W TC-D G24q-1 325 mA EC 18/20 LLEC 18/20
TC-T FSM-10 10 W TC-T GX24q-1 190 mA EC 13 LLEC 13
FSM-13 13 W TC-T GX24q-1 175 mA EC 13 LLEC 13
FSM-18 18 W TC-T GX24q-1 225 mA EC 18H LLEC 18H
FSM-26 26 W TC-T GX24q-1 325 mA EC 18/20 LLEC 18/20
TC-DD FSS-10 10 W TC-DD GR10q 180 mA EC 13 LLEC 13
2D-lamp FSS-16 16 W TC-DD GR10q 195 mA EC 16 LLEC 16
FSS-21 21 W TC-DD GR10q 260 mA EC 21 LLEC 21
FSS-28 28 W TC-DD GR10q 320 mA EC 18/20 LLEC 18/20
FSS-38 38 W TC-DD GR10q 430 mA EC 36/40 LLEC 36/40
TC-F flat FSS-18 18 W TC-F 2G10 375 mA EC 18/20 LLEC 18/20
FSS-18 2 x 18 W TC-F 2G10 375 mA EC 36/40 LLEC 36/40
FSS-24 24 W TC-F 2G10 345 mA EC 18/20 LLEC 18/20
FSS-36 36 W TC-F 2G10 435 mA EC 36/40 LLEC 36/40
Asia Pacific catalogue 2007 29www.tridonicatco.com.au
Fluorescent lamp ballast guide
Fluorescent lamps have combined the technology and
sophistication of fluorescent lighting with the compact
convenience of incandescent light fittings.
TridonicAtco offers a comprehensive range of standard EC energy
control ballasts as well as LLEC low loss ballasts designed to
operate compact fluorescent lamps from 4 W through to 65 W.
Lamp Code Wattage Length Cap Nominal current Standard ballast Low loss ballastT5-Lamp FD-4 4 W 150 mm G5 170 mA EC 4/6/8 LLEC 4/6/8
16 mm FD-6 6 W 225 mm G5 160 mA EC 4/6/8 LLEC 4/6/8
FD-6 2 x 6 W 225 mm G5 160 mA EC 13 LLEC 13
FD-8 8 W 300 mm G5 145 mA EC 4/6/8 LLEC 4/6/8
FD-8 2 x 8 W 300 mm G5 145 mA EC 13 LLEC 13
FD-13 13 W 525 mm G5 165 mA EC 13 LLEC 13
T8-Lamp FD-10 10 W 330 mm G13 230 mA EC 10 LLEC 10
26 mm FD-15 15 W 450 mm G13 310 mA EC 15 LLEC 15
FD-15 2 x 15 W 450 mm G13 310 mA EC 30 LLEC 30
FD-18 18 W 600 mm G13 370 mA EC 18/20 LLEC 18/20
FD-18 2 x 18 W 600 mm G13 370 mA EC 36/40 LLEC 36/40
FD-30 30 W 900 mm G13 365 mA EC 30 LLEC 30
FD-36 36 W 1,200 mm G13 430 mA EC 36/40 LLEC 36/40
FD-58 58 W 1,500 mm G13 670 mA EC 58/65 LLEC 58/65
T12-Lamp FD-20 20 W 600 mm G13 370 mA EC 18/20 LLEC 18/20
38 mm FD-20 2 x 20 W 600 mm G13 370 mA EC 36/40 LLEC 36/40
FD-40 40 W 1,200 mm G13 430 mA EC 36/40 LLEC 36/40
FD-65 65 W 1,500 mm G13 670 mA EC 58/65 LLEC 58/65
T8-Circline FC-22 22 W 210 mm G10q 400 mA EC 22 LLEC 22
26 mm FC-32 32 W 305 mm G10q 450 mA EC 32 LLEC 32
FC-40 40 W 406 mm G10q 420 mA EC 36/40 LLEC 36/40
TC-S and TC-L FSD-5 5 W TC-S 2G7 / G23 180 mA EC 9 LLEC 9
FSD-5 2 x 5 W TC-S 2G7 / G23 180 mA EC 13 LLEC 13
FSD-7 7 W TC-S 2G7 / G23 175 mA EC 9 LLEC 9
FSD-7 2 x 7 W TC-S 2G7 / G23 175 mA EC 13 LLEC 13
FSD-9 9 W TC-S 2G7 / G23 170 mA EC 9 LLEC 9
FSD-9 2 x 9 W TC-S 2G7 / G23 170 mA EC 13 LLEC 13
FSD-11 11 W TC-S 2G7 / G23 155 mA EC 9 LLEC 9
FSD-18 18 W TC-L 2G11 375 mA EC 18/20 LLEC 18/20
FSD-18 2 x 18 W TC-L 2G11 375 mA EC 36/40 LLEC 36/40
FSD-24 24 W TC-L 2G11 345 mA EC 18/20 LLEC 18/20
FSD-36 36 W TC-L 2G11 435 mA EC 36/40 LLEC 36/40
TC-D FSQ-10 10 W TC-D G24q-1 190 mA EC 13 LLEC 13
FSQ-13 13 W TC-D G24q-1 175 mA EC 13 LLEC 13
FSQ-18 18 W TC-D G24q-1 220 mA EC 18H LLEC 18H
FSQ-26 26 W TC-D G24q-1 325 mA EC 18/20 LLEC 18/20
TC-T FSM-10 10 W TC-T GX24q-1 190 mA EC 13 LLEC 13
FSM-13 13 W TC-T GX24q-1 175 mA EC 13 LLEC 13
FSM-18 18 W TC-T GX24q-1 225 mA EC 18H LLEC 18H
FSM-26 26 W TC-T GX24q-1 325 mA EC 18/20 LLEC 18/20
TC-DD FSS-10 10 W TC-DD GR10q 180 mA EC 13 LLEC 13
2D-lamp FSS-16 16 W TC-DD GR10q 195 mA EC 16 LLEC 16
FSS-21 21 W TC-DD GR10q 260 mA EC 21 LLEC 21
FSS-28 28 W TC-DD GR10q 320 mA EC 18/20 LLEC 18/20
FSS-38 38 W TC-DD GR10q 430 mA EC 36/40 LLEC 36/40
TC-F flat FSS-18 18 W TC-F 2G10 375 mA EC 18/20 LLEC 18/20
FSS-18 2 x 18 W TC-F 2G10 375 mA EC 36/40 LLEC 36/40
FSS-24 24 W TC-F 2G10 345 mA EC 18/20 LLEC 18/20
FSS-36 36 W TC-F 2G10 435 mA EC 36/40 LLEC 36/40
-
Mag
netic
bal
last
s
www.tridonic.com 17Asia Pacific Catalogue 2011
Technical tips for fluorescent lamp circuits
Asia Pacific catalogue 200730 www.tridonicatco.com.au
Technical tips for fluorescent lamp circuits
Tube does not attempt to strike Fuse blown. Check supply voltage trace broken fuse.no end glow from tube.
Faulty starter. Test starter switch in sound fitting
Faulty tube. Test tube in sound fitting. NOTE: If one or both cathodes are broken, check for faulty circuit(short circuit to earth or wrong control gear) before inserting new tube.
Open circuit. Test for open-circuit on ballast etc, or short to earth between ballast and tube.
Tube fails to strike Crossed leads in twin tube fitting. Check that the correct lampholders are connected to each tube ie leads connectedbright glow from one end of tube. to a given tube should have the same colour.
Short-circuit on Test for short-circuit across lampholder lead or forlampholder lead. short-circuit to earth on starter switch or wiring.
Tube does not attempt to strike Short-circuit on starter switch Test starter switch in sound fitting. If satisfactory, test switch both ends of tube glow brightly. or associated wiring. socket and wiring for short-circuit.
Tube flashes on and off Faulty tube (end of life). Check tube in sound fitting. At end of life, the lamp fails to maintain discharge.Symptoms are reduced light output, increased flicker and reddish glow from cathodes.
Low voltage or incorrect Test supply voltage at fitting-if low, check external wiring for excessive voltage drop (fuseholders,etc.)ballast rating. If sustained voltage at the fitting is persistently low, use lower voltage rated ballast.
Faulty starter. Test starter switch in sound fitting.
Low temperature. Screen open type fittings.
Crossed leads in twin tube fitting. Check that correct lampholders are connected to each tube,i.e leads connected to a given tube should have the same colour.
Lamp takes a long time to light. Some period is needed to start Measure the period. 2 to 6 seconds is normal.the lamp after switching on.
Supply voltage is low because: Check the line voltage and conditions.a) Overload on line.b) Lower voltage supplied.
The lamp quality is poor. Test with a known good lamp.
The lamp repeats on-off operation. Supply voltage is low. Check supply voltage with multimeter.
Incorrect wiring occurs in the apparatus. Check the wiring condition.
The lamp or the glow starter is Test with a known good lamp.damaged because of end of life.
Poor contact between Check the lamp contact condition.lamp pins in lampholders.
Excessive blackening at the end The source voltage doesnt Check the source voltage with a multimeter.(or both ends) of a lamp is found. match the ballast rating.
Incorrect wiring in apparatus or between Check the wire connecting condition.the supply and apparatus.
Too many switching operations of the The lamp or the ballast has failed. Change the lamp or the ballast with replacementlamp have been performed. and observe for a time.
Symptom Possible fault Test and remedy
Switch start circuitTwin series circuit
Magnetic ballasts for fluorescent lampsProduct information
Symptom Possible fault Test and remedy
Tube does not attempt to strike Fuse blown Check supply voltage replace broken fuse
no end glow from tube Supply fault Check supply volts and circuit fuse
Faulty starter Test starter switch in sound fitting
Faulty tube Test tube in sound fitting. NOTE: If one or both cathodes are broken, check for faulty circuit ( short circuit to earth or wrong control gear ) before inserting new tube.
Open circuit Test for open-circuit on ballast etc, or short to earth between ballast and tube
Tube fails to strike Crossed leads in twin tube fitting Check that the correct lampholders are connected to each tube leads connectedbright glow from one end of tube to a given tube should have the same colour
Short-circuit on lampholder lead Test for short-circuit across lampholder lead or forshort-circuit to earth on starter switch or wiring
Tube does not attempt to strike Short-circuit on starter switch Test starter switch in sound fitting. If satisfactory, test switch both ends of tube glow brightly or associated wiring socket and wiring for short-circuit.
Tube flashes on and off Faulty tube ( end of life ) Check tube in sound fitting. At end of life, the lamp fails to maintain discharge.Symptoms are reduced light output, increased flicker and reddish glow from cathodes.
Low voltage or incorrect ballast rating Test supply voltage at fitting-if low, check external wiring for excessive voltage drop ( fuseholders, etc. )If sustained voltage at the fitting is persistently low, use lower voltage rated ballast.
Faulty starter Test starter switch in sound fitting
Low temperature Screen open type fittings
Crossed leads in twin tube fitting Check that correct lampholders are connected to each tube,i.e leads connected to a given tube should have the same colour.
Lamp takes a long time to light Some period is needed to start Measure the period. 2 to 6 seconds is normalthe lamp after switching on
Supply voltage is low due to: Check the line voltage and conditionsa) Overload on line.b) Lower voltage supplied.
The lamp quality is poor Test with a known good lamp
The lamp repeats on-off operation Supply voltage is low Check supply voltage with multimeter
Incorrect wiring occurs in the apparatus Check the wiring condition
The lamp or the glow starter is Test with a known good lampdamaged because of end of life
Poor contact between Check the lamp contact conditionlamp pins in lampholders
Excessive blackening at the end The supply voltage doesnt Check the supply voltage with a multimeter( or both ends ) of a lamp is found match the ballast rating
Incorrect wiring in fitting or between Check the wire connecting conditionthe supply and fitting
Too many switching operations of the The lamp or the ballast has failed. Change the lamp or the ballast with replacementlamp have been performed and observe for a time.
-
www.tridonic.com18 Asia Pacific Catalogue 2011
Magnetic ballasts for fluorescent lampsEC series
Product description
Low energy consumption (EEI = B1 and B2)
Low temperature rise (EEI = B1 and B2)
Slim cross-section and compact
Low magnetic stray field
Long service life
Nomex class H gap for fixed calibration
Resistant to moisture and corrosion
Non-audible noise level
100 % final testing, including continuity, high voltage,
winding short-circuit and operating values
Technical dataLength L 85 mm
Hole spacing D 76 mm
Max. winding temperature tw 130 C
Push-in terminal 0.5 1.5 mm for rigid wires
Standards, page 9
Wiring diagrams and installation examples, page 74
EC 6 13 W, baseplate 85 mm, push-in terminalsLinear and circular fluorescent lamps, 220 V 50 Hz
T5
41
LD
KL
4,5
4131 31
8+1
Ordering dataWeight Type Article numberEnergy Efficiency Index EEI = B2
0.33 kg EC 13-04 B2 220/50 027A085 89000039
Energy Efficiency Index EEI = C
0.33 kg EC 13 OP 220/50 027A085 89003497Packaging: 40 pieces/carton, 2,880 pieces/pallet, 5,760 pieces/pallet
Specific technical dataLamp wattage Lamp length Lamp
diameterRated lamp
currentType1 Article number Core length
KL T Ballast loss Circuit power Compensation, parallel (cos o > 0.9)
Capacitor 10 % 250 V
Mains current
Mains start current
Energy Efficiency Index EEI = B21 x 13 W 517 mm 16 mm 0.165 A EC 13-04 B2 89000039 27 mm 55 K 4.3 W 17.3 W 0.48 1.5 F 0.09 A 0.11 A
2 x 6 W 212 mm 16 mm 0.160 A EC 13-04 B2 89000039 27 mm 55 K 4.2 W 16.2 W 0.46 1.5 F 0.08 A 0.11 A
2 x 8 W 288 mm 16 mm 0.145 A EC 13-04 B2 89000039 27 mm 55 K 3.8 W 18.0 W 0.56 1.5 F 0.09 A 0.13 A
Energy Efficiency Index EEI = C1 x 13 W 517 mm 16 mm 0.165 A EC 13 OP 89003497 27 mm 55 K 5.0 W 18.0 W 0.50 1.5 F 0.09 A 0.13 A
2 x 6 W 212 mm 16 mm 0.160 A EC 13 OP 89003497 27 mm 55 K 4.8 W 16.8 W 0.48 1.5 F 0.09 A 0.12 A
2 x 8 W 288 mm 16 mm 0.145 A EC 13 OP 89003497 27 mm 55 K 4.4 W 18.6 W 0.58 1.5 F 0.09 A 0.15 A1 Other wattages available on request
-
www.tridonic.com 19Asia Pacific Catalogue 2011
M
agne
tic b
alla
stsMagnetic ballasts for fluorescent lamps
EC series
Product description
Low energy consumption (EEI = B1 and B2)
Low temperature rise (EEI = B1 and B2)
Slim cross-section and compact
Low magnetic stray field
Long service life
Nomex class H gap for fixed calibration
Resistant to moisture and corrosion
Non-audible noise level
100 % final testing, including continuity, high voltage,
winding short-circuit and operating values
Technical dataLength L 150 mm
Hole spacing D 135.5 mm
Max. winding temperature tw 130 C
Push-in terminal 0.5 1.5 mm for rigid wires
Standards, page 9
Wiring diagrams and installation examples, page 74
EC 10 40 W, baseplate 150 mm, push-in terminalsLinear and circular fluorescent lamps, 220 V 50 Hz
T12T8
KLDL
31
19 29.5
5.5 x 7.5x5.5
541
Ordering dataWeight Type Article numberEnergy Efficiency Index EEI = B2
0.515 kg EC 18/20 B2 220/50 050A150 89003428
0.550 kg EC 36/40 B2 220/50 054A150 89003431
Energy Efficiency Index EEI = C
0.515 kg EC 10-05 220/50 050A150 89000185
0.515 kg EC 15-15 220/50 050A150 89000196
0.515 kg EC 18/20-16 220/50 050A150 89000208
0.515 kg EC 30-08 220/50 050A150 89000295
0.515 kg EC 36/40-10 220/50 050A150 89000325
Energy Efficiency Index EEI = no classification
0.425 kg EC 18 OD100K LN 220/50 040A150 89003600
0.505 kg EC 18/20 OP 220/50 050A150 89003329
0.430 kg EC 36 OD100K LN 220/50 040A150 89003587
0.500 kg EC 36/40 OP 220/50 050A150 89003302Packaging core length 40: 20 pieces/carton, 2,160 pieces/pallet, 3,960 pieces/pallet
Packaging core length 50 54: 20 pieces/carton, 1,800 pieces/pallet, 3,600 pieces/pallet
-
www.tridonic.com20 Asia Pacific Catalogue 2011
Magnetic ballasts for fluorescent lampsEC series
Specific technical dataLamp wattage Lamp length Lamp
diameterRated lamp
currentType2 Article number Core length
KL T Ballast loss Circuit
power Compensation, parallel (cos o > 0.9)
Capacitor 10 % 250 V
Mains current
Mains start current
Energy Efficiency Index EEI = B21 x 18 W 590 mm 26 mm 0.370 A EC 18/20 B2 89003428 50 mm 55 K 7.9 W 25.9 W 0.32 5.0 F 0.13 A 0.16 A
1 x 20 W 590 mm 38 mm 0.370 A EC 18/20 B2 89003428 50 mm 55 K 7.9 W 27.2 W 0.33 5.0 F 0.14 A 0.17 A
1 x 36 W 1,200 mm 26 mm 0.430 A EC 36/40 B2 89003431 54 mm 50 K 7.8 W 43.8 W 0.48 4.0 F 0.22 A 0.36 A
1 x 40 W 1,200 mm 38 mm 0.430 A EC 36/40 B2 89003431 54 mm 50 K 7.8 W 47.3 W 0.52 4.0 F 0.24 A 0.38 A
2 x 18 W 590 mm 26 mm 0.370 A EC 36/40 B2 89003431 54 mm 45 K 6.5 W 42.5 W 0.52 3.5 F 0.21 A 0.34 A
2 x 20 W 590 mm 38 mm 0.370 A EC 36/40 B2 89003431 54 mm 45 K 6.5 W 45.1 W 0.55 3.0 F 0.23 A 0.36 A
Energy Efficiency Index EEI = C1 x 10 W 330 mm 26 mm 0.230 A EC 10-05 1 89000185 50 mm 40 K 6.2 W 16.2 W 0.33 3.0 F 0.08 A 0.09 A
1 x 15 W 438 mm 26 mm 0.310 A EC 15-15 89000196 50 mm 50 K 8.5 W 23.5 W 0.34 3.5 F 0.12 A 0.14 A
1 x 18 W 590 mm 26 mm 0.370 A EC 18/20-16 89000208 50 mm 50 K 9.0 W 27.0 W 0.33 5.0 F 0.14 A 0.17 A
1 x 20 W 590 mm 38 mm 0.370 A EC 18/20-16 89000208 50 mm 50 K 9.0 W 28.3 W 0.35 5.0 F 0.14 A 0.18 A
1 x 30 W 895 mm 26 mm 0.365 A EC 30-08 89000295 50 mm 65 K 9.5 W 39.5 W 0.50 3.5 F 0.20 A 0.26 A
2 x 15 W 438 mm 26 mm 0.310 A EC 30-08 89000295 50 mm 65 K 8.1 W 38.1 W 0.56 3.0 F 0.19 A 0.29 A
1 x 36 W 1,200 mm 26 mm 0.430 A EC 36/40-10 89000325 50 mm 55 K 8.5 W 44.5 W 0.49 4.0 F 0.22 A 0.36 A
1 x 40 W 1,200 mm 38 mm 0.430 A EC 36/40-10 89000325 50 mm 55 K 8.5 W 48.0 W 0.53 4.0 F 0.24 A 0.39 A
2 x 18 W 590 mm 26 mm 0.370 A EC 36/40-10 89000325 50 mm 50 K 6.7 W 42.7 W 0.52 3.5 F 0.22 A 0.38 A
2 x 20 W 590 mm 38 mm 0.370 A EC 36/40-10 89000325 50 mm 50 K 6.7 W 45.3 W 0.56 3.0 F 0.23 A 0.40 A
Energy Efficiency Index EEI = no classification1 x 18 W 590 mm 26 mm 0.370 A EC 18 OD100K LN 89003600 40 mm 55 K 9.1 W 26.7 W 0.36 4.0 F 0.13 A 0.17 A
1 x 18 W 590 mm 26 mm 0.370 A EC 18/20 OP 89003329 50 mm 65 K 11.3 W 29.3 W 0.36 5.0 F 0.15 A 0.18 A
1 x 20 W 590 mm 38 mm 0.370 A EC 18/20 OP 89003329 50 mm 65 K 11.3 W 30.6 W 0.38 4.0 F 0.15 A 0.19 A
1 x 36 W 1,200 mm 26 mm 0.430 A EC 36 OD100K LN 89003587 40 mm 45 K 8.0 W 40.1 W 0.49 3.5 F 0.20 A 0.47 A
1 x 36 W 1,200 mm 26 mm 0.430 A EC 36/40 OP 89003302 50 mm 70 K 11.0 W 47.0 W 0.53 3.5 F 0.24 A 0.39 A
1 x 40 W 1,200 mm 38 mm 0.430 A EC 36/40 OP 89003302 50 mm 70 K 11.0 W 50.5 W 0.57 3.5 F 0.26 A 0.42 A
2 x 18 W 590 mm 26 mm 0.370 A EC 36/40 OP 89003302 50 mm 70 K 8.9 W 44.9 W 0.56 3.0 F 0.23 A 0.42 A
2 x 20 W 590 mm 38 mm 0.370 A EC 36/40 OP 89003302 50 mm 70 K 8.9 W 47.5 W 0.59 3.0 F 0.24 A 0.44 A1 Lamp not included in IEC 60081 or IEC 60901
2 Other wattages available on request
-
www.tridonic.com 21Asia Pacific Catalogue 2011
M
agne
tic b
alla
stsMagnetic ballasts for fluorescent lamps
EC series
Product description
Slim cross-section and compact
Low magnetic stray field
Long service life
Nomex class H gap for fixed calibration
Resistant to moisture and corrosion
Non-audible noise level
100 % final testing, including continuity, high voltage,
winding short-circuit and operating values
Technical dataLength L 150 mm
Hole spacing D 135.5 mm
Max. winding temperature tw 130 C
Screw terminal 2.5 mm
Standards, page 9
Wiring diagrams and installation examples, page 74
EC 15 40 W, baseplate 150 mm, screw terminalsLinear and circular fluorescent lamps, 220 V 50 Hz
T12T8
KLDL
31
19 29.5
5.5 x 7.5x5.5
541
Ordering dataWeight Type Article numberEnergy Efficiency Index EEI = C
0.515 kg EC 15 LD300K 220/50 050A150 89003701
0.515 kg EC 30 LD300K 220/50 050A150 89003702
Energy Efficiency Index EEI = no classification
0.425 kg EC 18 OD300K LN 220/50 040A150 89003620
0.505 kg EC 18/20 OP 220/50 050A150 DS 89003330
0.450 kg EC 36 OD300K LN 220/50 040A150 89003606
0.510 kg EC 36/40 OP 220/50 050A150 DS 89003331Packaging core length 40: 20 pieces/carton, 2,160 pieces/pallet, 3,960 pieces/pallet
Packaging core length 50: 20 pieces/carton, 1,800 pieces/pallet, 3,600 pieces/pallet
Specific technical dataLamp wattage Lamp length Lamp
diameterRated lamp
currentType1 Article number Core length
KL T Ballast loss Circuit
power Compensation, parallel (cos o > 0.9)
Capacitor 10 % 250 V
Mains current
Mains start current
Energy Efficiency Index EEI = C1 x 15 W 438 mm 26 mm 0.310 A EC 15 LD300K 89003701 50 mm 50 K 8.5 W 23.5 W 0.34 3.5 F 0.12 A 0.14 A
1 x 30 W 895 mm 26 mm 0.365 A EC 30 LD300K 89003702 50 mm 65 K 9.5 W 39.5 W 0.50 3.5 F 0.20 A 0.26 A
2 x 15 W 438 mm 26 mm 0.310 A EC 30 LD300K 89003702 50 mm 65 K 8.1 W 38.1 W 0.56 3.0 F 0.19 A 0.29 A
Energy Efficiency Index EEI = no classification1 x 18 W 590 mm 26 mm 0.370 A EC 18 OD300K LN 89003620 40 mm 55 K 9.1 W 26.7 W 0.36 4.0 F 0.13 A 0.17 A
1 x 18 W 590 mm 26 mm 0.370 A EC 18/20 OP 89003330 50 mm 65 K 11.3 W 29.3 W 0.36 5.0 F 0.15 A 0.18 A
1 x 20 W 590 mm 38 mm 0.370 A EC 18/20 OP 89003330 50 mm 65 K 11.3 W 30.6 W 0.38 4.0 F 0.15 A 0.19 A
1 x 36 W 1,200 mm 26 mm 0.430 A EC 36 OD300K LN 89003606 40 mm 45 K 8.0 W 40.1 W 0.49 3.5 F 0.20 A 0.47 A
1 x 36 W 1,200 mm 26 mm 0.430 A EC 36/40 OP 89003331 50 mm 70 K 11.0 W 47.0 W 0.53 3.5 F 0.24 A 0.39 A
1 x 40 W 1,200 mm 38 mm 0.430 A EC 36/40 OP 89003331 50 mm 70 K 11.0 W 50.5 W 0.57 3.5 F 0.26 A 0.42 A
2 x 18 W 590 mm 26 mm 0.370 A EC 36/40 OP 89003331 50 mm 70 K 8.9 W 44.9 W 0.56 3.0 F 0.23 A 0.42 A
2 x 20 W 590 mm 38 mm 0.370 A EC 36/40 OP 89003331 50 mm 70 K 8.9 W 47.5 W 0.59 3.0 F 0.24 A 0.44 A1 Other wattages available on request
-
www.tridonic.com22 Asia Pacific Catalogue 2011
Magnetic ballasts for fluorescent lampsEC series
Product description
Slim cross-section and compact
Low magnetic stray field
Long service life
Nomex class H gap for fixed calibration
Resistant to moisture and corrosion
Non-audible noise level
100 % final testing, including continuity, high voltage,
winding short-circuit and operating values
Technical dataLength L 195 mm
Hole spacing D 180 mm
Max. winding temperature tw 130 C
Push-in terminal 0.5 1.5 mm for rigid wires
Standards, page 9
Wiring diagrams and installation examples, page 74
EC 58 65 W, baseplate 195 mm, push-in terminalsLinear and circular fluorescent lamps, 220 V 50 Hz
T12T8
KLDL
31
19 29.5
5.5 x 7.5x5.5
541
Ordering dataWeight Type Article numberEnergy Efficiency Index EEI = C
0.885 kg EC 58/65-14 220/50 090A195 89000454Packaging: 20 pieces/carton, 1,200 pieces/pallet, 2,100 pieces/pallet
Specific technical dataLamp wattage Lamp length Lamp
diameterRated lamp
currentType1 Article number Core length
KL T Ballast loss Circuit
power Compensation, parallel (cos o > 0.9)
Capacitor 10 % 250 V
Mains current
Mains start current
Energy Efficiency Index EEI = C1 x 58 W 1,500 mm 26 mm 0.67 A EC 58/65-14 89000454 90 mm 45 K 12 W 70 W 0.48 7 F 0.35 A 0.55 A
1 x 65 W 1,500 mm 38 mm 0.67 A EC 58/65-14 89000454 90 mm 45 K 12 W 76 W 0.52 6 F 0.38 A 0.60 A1 Other wattages available on request
-
www.tridonic.com 23Asia Pacific Catalogue 2011
M
agne
tic b
alla
stsMagnetic ballasts for fluorescent lamps
EC series
Product description
Slim cross-section and compact
Low magnetic stray field
Long service life
Nomex class H gap for fixed calibration
Resistant to moisture and corrosion
Non-audible noise level
100 % final testing, including continuity, high voltage,
winding short-circuit and operating values
Technical dataLength L 195 mm
Hole spacing D 180 mm
Max. winding temperature tw 130 C
Screw terminal 2.5 mm
Standards, page 9
Wiring diagrams and installation examples, page 74
EC 58 65 W, baseplate 195 mm, screw terminalsLinear and circular fluorescent lamps, 220 V 50 Hz
T12T8
KLDL
31
19 29.5
5.5 x 7.5x5.5
541
Ordering dataWeight Type Article numberEnergy Efficiency Index EEI = C
0.885 kg EC 58/65 220/50 090A195 DS 89003590Packaging: 20 pieces/carton, 1,200 pieces/pallet, 2,100 pieces/pallet
Specific technical dataLamp wattage Lamp length Lamp
diameterRated lamp
currentType1 Article number Core length
KL T Ballast loss Circuit
power Compensation, parallel (cos o > 0.9)
Capacitor 10 % 250 V
Mains current
Mains start current
Energy Efficiency Index EEI = C1 x 58 W 1,500 mm 26 mm 0.67 A EC 58/65 89003590 90 mm 45 K 12 W 70 W 0.48 7 F 0.35 A 0.55 A
1 x 65 W 1,500 mm 38 mm 0.67 A EC 58/65 89003590 90 mm 45 K 12 W 76 W 0.52 6 F 0.38 A 0.60 A1 Other wattages available on request
-
www.tridonic.com24 Asia Pacific Catalogue 2011
Magnetic ballasts for fluorescent lampsEC series
Product description
Low energy consumption (EEI = B1 and B2)
Low temperature rise (EEI = B1 and B2)
Slim cross-section and compact
Low magnetic stray field
Long service life
Nomex class H gap for fixed calibration
Resistant to moisture and corrosion
Non-audible noise level
100 % final testing, including continuity, high voltage,
winding short-circuit and operating values
Technical dataLength L 85 mm
Hole spacing D 76 mm
Max. winding temperature tw 130 C
Push-in terminal 0.5 1.5 mm for rigid wires
Standards, page 9
Wiring diagrams and installation examples, page 74
EC 5 18 W, baseplate 85 mm, push-in terminalsCompact fluorescent lamps, 220 V 50 Hz
TC-DDTC-DTC-S
41
LD
KL
4,5
4131 31
8+1
Ordering dataWeight Type Article numberEnergy Efficiency Index EEI = B2
0.29 kg EC 9-05 B2 220/50 027A085 89000131
0.33 kg EC 13-04 B2 220/50 027A085 89000039
0.29 kg EC 18H-01 B2 220/50 027A085 89000096
Energy Efficiency Index EEI = C
0.33 kg EC 13 OP 220/50 027A085 89003497Packaging: 40 pieces/carton, 2,880 pieces/pallet, 5,760 pieces/pallet
-
www.tridonic.com 25Asia Pacific Catalogue 2011
M
agne
tic b
alla
stsMagnetic ballasts for fluorescent lamps
EC series
Specific technical dataLamp wattage Lamp type Rated lamp
currentType1 Article number Core length
KL T Ballast loss Circuit
power Compensation, parallel (cos o > 0.9)
Capacitor 10 % 250 V
Mains current
Mains start current
Energy Efficiency Index EEI = B21 x 5 W TC-S 0.180 A EC 9-05 B2 89000131 27 mm 55 K 5.7 W 11.1 W 0.28 3.0 F 0.06 A 0.06 A
1 x 7 W TC-S 0.175 A EC 9-05 B2 89000131 27 mm 55 K 5.5 W 12.6 W 0.33 2.0 F 0.06 A 0.07 A
1 x 9 W TC-S 0.170 A EC 9-05 B2 89000131 27 mm 55 K 5.2 W 13.9 W 0.38 2.0 F 0.07 A 0.08 A
1 x 11 W TC-S 0.155 A EC 9-05 B2 89000131 27 mm 55 K 4.9 W 16.7 W 0.49 1.5 F 0.08 A 0.11 A
1 x 10 W TC-D 0.180 A EC 13-04 B2 89000039 27 mm 55 K 4.8 W 14.8 W 0.36 2.0 F 0.07 A 0.08 A
1 x 13 W TC-D 0.165 A EC 13-04 B2 89000039 27 mm 55 K 4.4 W 17.4 W 0.47 2.0 F 0.09 A 0.11 A
1 x 10 W TC-DD 0.180 A EC 13-04 B2 89000039 27 mm 55 K 4.6 W 15.1 W 0.39 2.0 F 0.08 A 0.09 A
2 x 5 W TC-S 0.180 A EC 13-04 B2 89000039 27 mm 55 K 4.6 W 15.4 W 0.40 2.0 F 0.08 A 0.09 A
2 x 7 W TC-S 0.175 A EC 13-04 B2 89000039 27 mm 55 K 4.3 W 18.5 W 0.51 1.5 F 0.09 A 0.12 A
2 x 9 W TC-S 0.170 A EC 13-04 B2 89000039 27 mm 55 K 4.0 W 21.8 W 0.64 1.5 F 0.11 A 0.15 A
1 x 18 W TC-D 0.220 A EC 18H-01 B2 89000096 27 mm 50 K 5.8 W 23.8 W 0.49 2.0 F 0.12 A 0.18 A
Energy Efficiency Index EEI = C1 x 13 W TC-D 0.165 A EC 13 OP 89003497 27 mm 55 K 5.2 W 18.2 W 0.49 2.0 F 0.09 A 0.12 A
1 x 10 W TC-D 0.180 A EC 13 OP 89003497 27 mm 55 K 5.6 W 15.6 W 0.38 2.0 F 0.08 A 0.10 A
1 x 10 W TC-DD 0.180 A EC 13 OP 89003497 27 mm 55 K 5.3 W 15.8 W 0.41 2.0 F 0.08 A 0.11 A
2 x 5 W TC-S 0.180 A EC 13 OP 89003497 27 mm 55 K 5.3 W 16.1 W 0.42 2.0 F 0.08 A 0.11 A
2 x 7 W TC-S 0.175 A EC 13 OP 89003497 27 mm 55 K 5.0 W 19.2 W 0.53 1.5 F 0.10 A 0.14 A
2 x 9 W TC-S 0.170 A EC 13 OP 89003497 27 mm 55 K 4.7 W 22.5 W 0.66 1.5 F 0.11 A 0.17 A1 Other wattages available on request
-
www.tridonic.com26 Asia Pacific Catalogue 2011
Magnetic ballasts for fluorescent lampsEC series
Product description
Low energy consumption (EEI = B1 and B2)
Low temperature rise (EEI = B1 and B2)
Slim cross-section and compact
Low magnetic stray field
Long service life
Nomex class H gap for fixed calibration
Resistant to moisture and corrosion
Non-audible noise level
100 % final testing, including continuity, high voltage,
winding short-circuit and operating values
Technical dataLength L 150 mm
Hole spacing D 135.5 mm
Max. winding temperature tw 130 C
Push-in terminal 0.5 1.5 mm for rigid wires
Standards, page 9
Wiring diagrams and installation examples, page 74
EC 18 38 W, baseplate 150 mm, push-in terminalsCompact fluorescent lamps, 220 V 50 Hz
TC-DDTC-DTC-FTC-L
KLDL
31
19 29.5
5.5 x 7.5x5.5
541
Ordering dataWeight Type Article numberEnergy Efficiency Index EEI = B2
0.515 kg EC 18/20 B2 220/50 050A150 89003428
0.550 kg EC 36/40 B2 220/50 054A150 89003431
Energy Efficiency Index EEI = C
0.515 kg EC 18/20-16 220/50 050A150 89000208
0.515 kg EC 36/40-10 220/50 050A150 89000325
Energy Efficiency Index EEI = no classification
0.425 kg EC 18 OD100K LN 220/50 040A150 89003600
0.505 kg EC 18/20 OP 220/50 050A150 89003329
0.430 kg EC 36 OD100K LN 220/50 040A150 89003587
0.500 kg EC