Installation InstructionsBulletin 1585BP UTP Plug

IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE.Refer to the product catalog pages for additional information.

Cut the rip cord asclose to the jacket as

possible. Fan pairs intoproper color code (see nextframe).

Using a cable stripper,remove approximately

38 mm (1.5 in.) of sheath-ing.

3 4

Place modular plugover wire ends being

sure to maintain color code.Insure that the pairs are in-serted all the way into themodular plug including theinner jacket. The inner jack-et should be directly underthe plug’s strain relief tab.

7 8 Using a crimp tool(1585A--JCRIMP),terminate the modularplug to the cable.

Product includes: flexnut, plug assembly,

and modular plug.

1 Place plug housingover the industrial

cable as shown, flex nutmay need to be loosened.

2

Note:Outer cablediameter range 4…8 mm(0.160…0.315 in.)

5 6

T568AColor Code

T568BColor Code

Color Key:1=White/Green2=Green3=White/Orange4=Blue5=White/Blue6=Orange7=White/Brown8=Brown

Color Key:1=White/Orange2=Orange3=White/Green4=Blue5=White/Blue6=Green7=White/Brown8=Brown

= Tip = Ring

1 82 3 4 5 6 7

Pair 3 Pair 1 Pair 4

Pair 2

1 82 3 4 5 6 7

Pair 1 Pair 4Pair 2

Pair 3

After fanning pairs toproper color code,

hold the pairs close to thejacket and trim conductorsleaving 12 mm (0.5 in.) ex-tending from the inner jack-et.

12 mm(0.5 in.)

Insert the modularplug into the plug

housing. Align the latch withthe LATCH slot, depresslatch and insert plug intoplug housing until it bottomsout.

Slide the plug housingup the cable and align

with the modular plug.

9 10

2

PN--26346Printed in USA

The original dustcover (1585BP--MCAP) can be usedto insure properseating of plug.

11 12 While maintainingpressure on plug or

keeping dust cap engaged,tighten the flex nut to0.5 N•m (5 in•lbs).

Place optional dustcap (1585BP--MCAP)

chain over plug housing andposition between flex nutand plug assembly asshown. Tighten chain tosecure.

13

ATTENTION: To assist safe installation, complywith the following:

A. Use caution when installing or modifyingtelecommunications circuits.

B. Never touch uninsulated wire terminalsunless the circuit has been disconnected.

C. Never install this device in a wet location.

D. Never install wiring during a lightning storm.

IP67 rating can only be achieved when usingan IP67 rated enclosure with a properly assembledindustrial outlet or industrial plug cap.