ACSS511: Statutory Control 3
Explain the operation of the building control system in England and Wales.
4CSS594: Statutory Control 4
Concerned with ‘building control’ Purpose of Building Regulations Most building work covered by regs Must demonstrate compliance Achieved by independent check on building
work Can be undertaken by LA or AI
Planning Building Control
Concerned with:◦ Land use◦ Amenity◦ Location◦ Siting◦ Design◦ Layout◦ Appearance
Concerned with:◦ How a building is
constructed so that it can be used safely
◦ Energy conservation◦ Access for all
4CSS594: Statutory Control 5
4CSS594: Statutory Control 6
4CSS594: Statutory Control 7
The Building Act 1984
4CSS594: Statutory Control 8
Sec of State empowered “to make regulations with respect to the design and construction of buildings”
•To secure health, safety, welfare and convenience of people•Furthering conservation of fuel and power•Preventing waste, misuse, contamination of water
4CSS594: Statutory Control 9
The Sustainable and Secure Buildings Act 2004
4CSS594: Statutory Control 10
Furthering the protection or enhancement of the environment
Facilitating sustainable development Furthering the prevention or detection of
crime
4CSS594: Statutory Control 11
By means of a Statutory Instrument:
A form of legislation which allows the provisions of an Act of Parliament to be brought into force or altered without having to pass a new Act
4CSS594: Statutory Control 12
The Building Regulations 2010
4CSS594: Statutory Control 13
Building work Material change of use
4CSS594: Statutory Control 14
Erecting or extending a building
Material alteration of a building Provision or extension of
controlled services and fittings Inserting insulation into a
cavity wall Underpinning a building Work affecting thermal
elements, energy status or energy performance
4CSS594: Statutory Control 15
becomes a dwelling will contain a flat becomes a hotel becomes an institution becomes a public building was exempt but is no longer contains greater or lesser
number of dwellings will be used as a shop
A change of use is deemed to have occurred if the building:
Note: change of use under planning law is different
4CSS594: Statutory Control 16
Under Schedule 2 of Building Regs
Seven classes of exempt buildings and work
Do the Building Regulations apply?
ACSS511: Statutory Control 17
4CSS594: Statutory Control 18
The regulations do not tell us how to construct buildings
The regulations are short and simple and contain no technical detail
4CSS594: Statutory Control 19
Part A Structural safetyPart B Fire safetyPart C Site preparation and resistance to contaminants and moisturePart D Toxic substancesPart E Resistance to the passage of soundPart F VentilationPart G Sanitation, hot water safety and water efficiencyPart H Drainage and waste disposalPart J Combustion appliances and fuel storage systemsPart K Protection from falling, collision and impactPart L Conservation of fuel and powerPart M Access to and Use of BuildingsPart N GlazingPart P Electrical safety
4CSS594: Statutory Control 20
Broad objectives or functions which building design and construction is expected to achieve
‘Reasonable’, ‘adequate’, ‘appropriate’
4CSS594: Statutory Control 21
They are expressed in broad functional terms
The requirements do not state how a building should be constructed.
Examples……….
4CSS594: Statutory Control 22
Requirement A1: Loading(1) The building shall be constructed so that the
combined dead, imposed and wind loads are sustained and transmitted by it to the ground - (a)safely; and
(b)without causing such deflection or deformation of any part of the building, or such movement of the ground, as will impair the stability of any part of another building.
(2) In assessing whether a building complies with sub-paragraph (1) regard shall be had to the imposed and wind loads to which it is likely to be subjected in the ordinary course of its use for the purpose for which it is intended.
4CSS594: Statutory Control 23
Requirement C2: Resistance to MoistureThe walls, floors and roof of the building shall
adequately protect the building and people who use the building from harmful effects caused by:
(a) ground moisture;
(b) precipitation including wind-driven spray;
(c) interstitial and surface condensation; and
(d) spillage of water from or associated with sanitary fittings or fixed appliances.
4CSS594: Statutory Control 24
Requirement F1: Means of ventilationThere shall be adequate means of ventilation provided for people in the building.
4CSS594: Statutory Control 25
Guidance on how the requirements can be met is provided in a series of documents known as…….
4CSS594: Statutory Control 26
Documents providing guidance on how the requirements of the Building Regulations can be met
4CSS594: Statutory Control 27
ADs to correspond with each of technical ‘parts’ of Building Reg requirements
4 ADs covering Part L Additional AD for Reg 7:
Material and workmanship 18 ADs in all
4CSS594: Statutory Control 28
Important to appreciate that ADs provide guidance.
It is not the only way of achieving compliance.
4CSS594: Statutory Control 29
“Approved Documents are intended to provide guidance for some of the more common building situations. However, there may well be alternative ways of achieving compliance with the requirements. Thus there is no obligation to adopt any particular solution contained in an Approved Document if you prefer to meet the requirement in some other way.”
4CSS594: Statutory Control 30
There is a legal presumption that following the guidance is evidence tending to support compliance with the Building Regulations.
4CSS594: Statutory Control 31
You are free to use alternative approaches, provided compliance with the Building Regulations can be demonstrated
It is up to the designer or the builder to demonstrate that they have satisfied the requirements
4CSS594: Statutory Control 32
Requirement C2: Resistance to MoistureThe walls, floors and roof of the building shall
adequately protect the building and people who use the building from harmful effects caused by:
(a) ground moisture;
(b) precipitation including wind-driven spray;
(c) interstitial and surface condensation; and
(d) spillage of water from or associated with sanitary fittings or fixed appliances.