vibration measurement at atf2

21
Vibration Measurement at ATF2 R. Sugahara (KEK) Measured on 17 and 30 June 2008

Upload: mackensie-lott

Post on 03-Jan-2016

52 views

Category:

Documents


1 download

DESCRIPTION

Vibration Measurement at ATF2. R. Sugahara (KEK) Measured on 17 and 30 June 2008. X. North. Y. West. Layout. QF17X. QM12FF. Instruments. Seismometers MG-102S of Tokkyokiki Corporation (Accelerometer) Sensible frequency region: 0.1 - 400Hz - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Vibration Measurement at ATF2

Vibration Measurementat ATF2

R. Sugahara (KEK)

Measured on 17 and 30 June 2008

Page 2: Vibration Measurement at ATF2

Y

X

West

North

Layout

QM12FFQF17X

Page 3: Vibration Measurement at ATF2

Instruments

Seismometers MG-102S of Tokkyokiki Corporation (Accelerometer) Sensible frequency region: 0.1 - 400Hz Resolution: 0.1mGal (Gal = cm/sec2) Sensitivity: 1 Gal/V

Data logger Graduo of Ono Sokki Co., Ltd.

Page 4: Vibration Measurement at ATF2

I On concrete blocks

Page 5: Vibration Measurement at ATF2

1-1 Concrete Block (---) versus Floor (---)PSD (Power Spectrum Density)

Y (W-E)X (N-S) V

0.1 1 10 100 0.1 1 10 100 0.1 1 10 100

Frequency (Hz)

10-4

10-8

10-12

PS

D (

mm

2/H

z)

Page 6: Vibration Measurement at ATF2

1-2 Concrete Block (---) versus Floor (---)Integrated PSD

Y (W-E)X (N-S) V

0.1 1 10 100 0.1 1 10 100 0.1 1 10 100

Frequency (Hz)

10-3

10-6

Inte

g.

PS

D (

mm

)

Page 7: Vibration Measurement at ATF2

1-3 PSD RatioConcrete Block / Floor

Frequency (Hz)

QM12

Page 8: Vibration Measurement at ATF2

II On magnet without mover

Page 9: Vibration Measurement at ATF2

2-1 QF17X (---) versus Floor (---)PSD (Power Spectrum Density)

Y (W-E)X (N-S) V

0.1 1 10 100 0.1 1 10 100 0.1 1 10 100

Frequency (Hz)

10-4

10-8

10-12

PS

D (

mm

2/H

z)

Page 10: Vibration Measurement at ATF2

2-2 QF17X (---) versus Floor (---)Integrated PSD

Y (W-E)X (N-S) V

0.1 1 10 100 0.1 1 10 100 0.1 1 10 100

Frequency (Hz)

10-3

10-6

Inte

g.

PS

D (

mm

)

Page 11: Vibration Measurement at ATF2

2-3 PSD RatioQF17X (no mover) / Floor (---)

Frequency (Hz)

Page 12: Vibration Measurement at ATF2

III On magnet with mover

Page 13: Vibration Measurement at ATF2

3-1 QM12 (---) versus Floor (---)PSD (Power Spectrum Density)

Y (W-E)X (N-S) V

0.1 1 10 100 0.1 1 10 100 0.1 1 10 100

Frequency (Hz)

10-4

10-8

10-12

PS

D (

mm

2/H

z)

Page 14: Vibration Measurement at ATF2

3-2 QM12 (---) versus Floor (---)Integrated PSD

Y (W-E)X (N-S) V

0.1 1 10 100 0.1 1 10 100 0.1 1 10 100

Frequency (Hz)

10-3

10-6

Inte

g.

PS

D (

mm

)

Page 15: Vibration Measurement at ATF2

3-3 PSD RatioQM12 (with mover) / Floor

Frequency (Hz)

QM12

Page 16: Vibration Measurement at ATF2

Summary1. On the concrete base block • Amplification factor is quite small in the frequency region less than 40Hz, especially in vertical direction

2. On the top of the magnet without mover, QF17X • There are resonances at 35Hz in X direction, and at 55Hz in Y • No obvious resonance is observed in V direction • Amplification factor is about 100 in amplitude at X and Y resonance peaks • Out of resonance region, amplification factor is about 3 or less in the frequency region higher than 15Hz in X and Y direction • Amplification factor is less than 2 in the frequency region less than 15Hz. Especially it is quite small in V direction in the frequency region less than 50HZ

Page 17: Vibration Measurement at ATF2

Summary (cont.)3. On the top of the magnet with mover, QM12FF • There are resonances at 20Hz in X and Y direction, and at 70Hz in V • Amplification factor is about 100 in amplitude at resonance peaks • Out of resonance region, amplification factor is about 3 or less in the frequency region 10 - 45Hz in X and Y direction • Amplification factor is less than 2 in the frequency region less than 10Hz • Especially it is quite small in V direction in the frequency region less than 40HZ except for a small resonance at 21Hz, where the amplification factor is about 3

4. Integrated amplitude (nm) 1Hz X Y V ; 10Hz X Y V ; 20Hz X Y V Floor 60 60 80 ; 06 08 15 ; 02 2.3 03 QF17X 60 60 80 ; 20 17 15 ; 20 15 04 --- Floor 40 40 40 ; 09 04 12 ; 3.4 1.8 4.5 QM12FF 90 55 40 ; 80 30 15 ; 80 12 09

Page 18: Vibration Measurement at ATF2

< --- >

Page 19: Vibration Measurement at ATF2

1b-1 Concrete Block (---) versus Floor (---)PSD (Power Spectrum Density)

Y (W-E)X (N-S) V

0.1 1 10 100 0.1 1 10 100 0.1 1 10 100

Frequency (Hz)

10-4

10-8

10-12

PS

D (

mm

2/H

z)

Page 20: Vibration Measurement at ATF2

1b-2 Concrete Block (---) versus Floor (---)Integrated PSD

Y (W-E)X (N-S) V (W-E)

0.1 1 10 100 0.1 1 10 100 0.1 1 10 100

Frequency (Hz)

10-3

10-6

Inte

g.

PS

D (

mm

)

Page 21: Vibration Measurement at ATF2

1b-3 PSD RatioConcrete Block / Floor

Frequency (Hz)