urban design brief doman developments inc ... - london ... · the subject lands are located within...
TRANSCRIPT
Urban Design Brief February 5, 2014 Doman Developments Inc. - Corporate Commercial Campus
Urban Design Brief
Proposed Residential Apartment Development
2179-2201 Hyde Park Road
Old Oak Properties Inc.
February 5, 2014
AUGUST 22, 2014
Urban Design Brief Old Oak Properties 2179-2201 Hyde Park Road
Page | 1 Zelinka Priamo Ltd.
Table of Contents
Introduction
SECTION 1 – Land Use Planning Context
1.1 The Subject Lands
1.2 The Proposal
1.3 Design Goals and Objectives
1.4 Design Response to City Documents
1.4.1 Multi-Family, High Density Residential Policies
1.4.2 Urban Design Policies
1.5 Spatial Analysis
1.5.1 Community Context (400m)
1.5.2 Community Context (800m)
1.6 SWOT Analysis
1.7 Conclusions
SECTION 2 – Design Principles and Design Responses
2.1 Conceptual Design
2.2 Public Realm
2.3 Sustainability Techniques
Figures
Figure 1 Subject Lands Figure 2 Streetview image of Subject Lands Figure 3 Streetview image of Subject Lands Figure 4 Official Plan Map Figure 5 Zoning By-Law Map Figure 6 Site Plan Figure 7 Community Context Map (400m and 800m) Figure 8 Landscape Plan Figure 9 3D Rendering of Building Figure 10 3D Rendering of Building Figure 11 3D Rendering of Building Figure 12 885 Southdale Road Image Figure 13 885 Southdale Road Image Figure 14 885 Southdale Road Image Figure 15 Southdale Road Panorama Figure 16 North Elevation Figure 17 East Elevation Figure 18 South Elevation Figure 19 West Elevation Appendix A Neighbourhood Character Statement
Appendix B Compatibility Report
Urban Design Brief Old Oak Properties 2179-2201 Hyde Park Road
Page | 2 Zelinka Priamo Ltd.
Introduction
The purpose of this Urban Design Brief is to provide design details of the proposed development by Old
Oak Properties Inc. of three apartment buildings and an associated parking structure at 2179-2201 Hyde
Park Road, as part of the site plan approval application for the property.
SECTION 1 – Land Use Planning Context
The subject lands are located within the City of London municipal boundaries (Figure 1). More
specifically, the site is located at the southeast corner of the Hyde Park Road and future Dyer Road, in
the northwest quadrant of the City of London, at the limit of the Urban Growth Boundary.
1.1 The Subject Lands
The subject lands are made up of two separate parcels; 2179 Hyde Park Road is 3.69 ha (9.12 acres) in
area and 2201 Hyde Park Road is 0.35 ha (0.86 acres) in area. In total, the subject lands are 3.95 ha
(9.76 ac) after the required road widening on Hyde Park Road and have 160 m (525 ft) of frontage along
Hyde Park Road, an arterial road, and 245 m (804 ft) of frontage along Dyer Drive, a future local road.
The subject lands were previously occupied by a landscape supply establishment (Fisher Topsoil), but
are currently vacant. Topographically, the subject lands are relatively flat, with a slight slope from west to
east. Vegetation on the lands consists of sporadic trees and bushes. (Figures 2-3)
The surrounding area consists of agricultural and commercial uses, with a large area to the east intended
as future residential lands. As the subject lands lie at the westerly limit of the City of London Urban
Growth Boundary, the majority of the lands to the west are used for agricultural uses, with a small section
of rural residential and commercial uses along Hyde Park Road. A fire station lies adjacent to the subject
lands to the north, across Dyer Drive, and medium density residential lands are located adjacent to the
existing fire hall. Single-family dwellings are being constructed to the east of the subject lands along
Tokala Trail. Lands adjacent to the east are current vacant, but are designated for high density
residential development. Lands to the south and southeast are occupied by a Lowe’s home improvement
store and retail and restaurant uses as part of the larger commercial node at Fanshawe Park Road and
Hyde Park Road.
Urban Design Brief Old Oak Properties 2179-2201 Hyde Park Road
Page | 3 Zelinka Priamo Ltd.
1.2 The Proposal
Old Oak Properties Inc. is proposing to construct three apartment buildings on the subject lands, with
terraced profiles that will achieve a maximum of 16 storeys and contain 600 units (200 units per building).
A four storey podium anchors the base of each building along the street frontages. The proposed
buildings are “L” shaped in plan and are located at the northwest, northeast, and southwest corners of the
subject lands (Figures 6-7). Parking is to be provided by small surface parking areas located close to the
buildings as well as a two-storey parking structure located in the southwest corner of the subject lands
which will be screened from public view by the proposed apartment buildings and landscaping. Vehicular
access to the site is proposed by way of a full turn access from Dyer Drive located centrally along the
Dyer Drive frontage as well as a secondary full turn access near the northeast corner of the site.
The proposed apartment buildings employs many of the desirable and praiseworthy design attributes of
the recent high-density residential development at 885 Southdale Road, at the corner of Southdale Road
and Pomeroy Lane. As such, this report includes images of the completed 16-storey apartment building
that addresses the corner of Pomeroy Lane and Southdale Road (Figures 12-15). As the remainder of the
development is currently under construction, images of the completed forecourt, amenity area, and
landscaping are not available.
1.3 Design Goals and Objectives
The overall goal for the development of these lands is to provide an attractive urban residential
environment that contributes to the appearance and quality of the public realm. In order to effectively
achieve this goal, the following design objectives have been identified:
Provide a building design that uses the combination of its massing, orientation, pedestrian
entrances, architectural elements, detailing, and material selection to create an attractive street
presence along Hyde Park Road and Dyer Drive;
Introduce clearly articulated definitions (which includes a four-storey podium) between the base,
body, and caps of buildings by terracing the upper floors, cladding the lower three floors and
portions of the fourth floors with architectural stone;
Address the intersection of Hyde Park Road and Dyer Drive with the massing and architectural
treatment of the northwesterly apartment building, including large curved balconies that front onto
the corner;
Develop site grading and finished floor heights that best integrate the proposed buildings with the
elevation of adjacent rights-of-ways;
Screen the parking areas and parking structure through building placement and sloped
landscaping and locate them away from public view;
Urban Design Brief Old Oak Properties 2179-2201 Hyde Park Road
Page | 4 Zelinka Priamo Ltd.
Provide a quality pedestrian experience along this section of Hyde Park Road and Dyer Drive
through the introduction of trees and vegetation along the streetscape. This will establish a
positive standard for the urban streetscape in this developing area;
Develop a landscape plan that helps to visually integrate the new development into the
surrounding environment;
Create an appealing interface between the buildings and the bounding roads through the design
and construction of an attractive, curb free, landscaped forecourt between the front facade and
Hyde Park Road;
Limit sun shadowing impacts on the adjacent properties through building locations;
Locate all waste and recycling storage within the apartment buildings and provide pick-up areas
that are located away from public view; and
Position the resident’s outdoor common spaces to contribute to views to and from the public
realm.
1.4 Design Response to City Documents
The design polices relevant to the proposed development are taken from the City of London Official Plan.
The subject lands are currently designated “Multi-Family, High-Density Residential” in the City of London
Official Plan and the policies that are relevant to the proposed development are outlined below.
1.4.1 Multi-Family, High Density Residential Policies
The proposed development is consistent with the policies under Section 3.4.1 of the Official Plan since
the primary permitted uses within the Multi-Family, High Density Residential designation include low-rise
and high-rise apartment buildings; apartment hotels; multiple-attached dwellings; emergency care
facilities; nursing homes; rest homes; homes for the aged; and rooming and boarding houses.
1.4.2 Urban Design Policies
Section 11.1.1 of the City of London Official Plan provides the policy framework to ensure that urban
design principles are incorporated into the designs of new buildings and structures within the City. The
design of the proposed development is consistent with the relevant policies as follows and are further
detailed in Section Two of this Brief:
There are no significant natural features on or adjacent to the site, but the design of the proposed
development will provide new enhanced landscaped edges along both Hyde Park Road and Dyer
Drive (Subsection i);
The proposed development will add new trees and vegetation to the site (Subsection ii);
Urban Design Brief Old Oak Properties 2179-2201 Hyde Park Road
Page | 5 Zelinka Priamo Ltd.
The site does not benefit from any views of natural features or existing landmarks; however, the
proposed development will act as an important and visible landmark at the intersection of Hyde
Park Road and Dyer Drive, positively defining a major entrance to the City of London from the
north (Subsection iii);
This location serves as a gateway to the city from the north. Hyde Park Road is an important
north/south arterial road and any high-density development in this location, as permitted by the
current zoning, will be highly visible. With this in mind, the proposed development has been
designed to respond to the obligation to provide a high quality architectural, site and landscape
design (Subsection iv);
The site of the proposed development is flanked on the north, east and west sides by
undeveloped lands. To the south lies an existing large-scale home improvement store, associated
parking area, and a stormwater management pond. The proposed development will have the
opportunity to encourage a desirable architectural character for the streetscape along Hyde Park
Road and Dyer Drive and the future residential areas to the north and east; (Subsection v);
The proposed development will replace undeveloped land with a use and built form that is
compatible with the objectives of the Official Plan and the surrounding built and developing uses.
(Subsection vi);
The proposed development has been designed to establish a strong positive precedent for this
section of the Hyde Park Road and future Dyer Drive streetscape and to allow for their seamless
integration as fully urbanized roads (Subsection vii);
The proposed development enhances the pedestrian environment by providing enhanced
landscaped areas, building entrances with canopies oriented to public streets, and an extensive
landscaped forecourt with decorative paving (Subsection vi);
The location of the subject lands and the siting, massing, and orientation of the proposed
development will result in little potential adverse impact on the year-round sunlight conditions on
adjacent properties. The subject lands are located to the north of the adjacent home improvement
store and associated parking lot, and consequently, will not project shadows onto that property.
The lands located to the east of the subject lands are intended to be developed as high-density
residential. However, the building design and siting will allow for sunlight penetration through the
subject lands onto lands to the west during late afternoon hours. Adjacent to the existing fire hall,
lands to the north are also intended for residential development and are separated from the
subject lands by the Dyer Drive road allowance, over which the majority of shadows will be
projected (Subsection ix);
Landscaping will be used to enhance the appearance of building setbacks and yard areas, and to
screen parking, loading, garbage and service facilities from adjacent properties and the street
(Subsection x);
Urban Design Brief Old Oak Properties 2179-2201 Hyde Park Road
Page | 6 Zelinka Priamo Ltd.
The proposed buildings have been positioned to define useable and secure open space areas
and privacy for the individual dwelling units. At grade, a landscaped forecourt has been positioned
between the proposed buildings and the street. Also, at grade, a landscaped outdoor common
area with a pond, decorative paving, seating, and a covered area has been centrally located
between the three proposed apartment buildings. Additional outdoor common areas have been
provided in the form of landscaped open outdoor terraces located on the 15th floors of each
apartment building overlooking the pond area (Subsection xi);
The building has been designed to facilitate access and use by incorporating the City of London
Facility Accessibility and Design Standards (Subsection xii);
The majority of parking for tenants and visitors has been provided in a two-level parking structure
that will be screened by the proposed apartment buildings and sloped landscaping. This parking
structure has been designed to be compact in form and to minimize the amount of exposed
surface parking. Access and loading areas have been designed to facilitate manoeuvrability on
site and to reduce any potential traffic flow disruption resulting from turning movements to and
from the property (Subsection xiii);
The proposed buildings have been designed and located to minimize the loss of privacy for
adjacent properties. Elevations containing larger window and balcony areas have been located
furthest away from the future residential uses to the east (Subsection xiv);
In addition to the identified outdoor common areas, each apartment unit has been provided with
an individual exterior balcony (Subsection xv);
Indoor and outdoor recreational and amenity space has been provided including exercise rooms
and community rooms (Subsection xvii);
Waste handling, composting and recycling facilities have been incorporated into the site design
(Subsection xix);
Where practical, the proposed apartment buildings will make use of appropriate sustainability
techniques (Subsection xx); and
The design, massing, orientation, and siting of the proposed buildings have been developed to
create a new landmark and to act as a gateway to City of London and the future residential
community to the east (Subsection xxi).
1.5 Spatial Analysis
The subject lands are comprised of two parcels of land located on the southeast corner of Hyde Park
Road and Dyer Drive. The intersection of Hyde Park Road and Fanshawe Park Road is the next
intersection to the south of the subject lands, while the intersection of Hyde Park Road and Sunningdale
Road is the nearest existing intersection to the north of the subject lands. Currently, Hyde Park Road is
making the transition from a rural road to an urban road, and consequently, much of the streetscape is
undeveloped and the treatment of the lands within the public rights-of-way is an inconsistent patchwork of
Urban Design Brief Old Oak Properties 2179-2201 Hyde Park Road
Page | 7 Zelinka Priamo Ltd.
street typology. There are no public sidewalks on either side of Hyde Park north of Fanshawe Park Road,
nor any on the existing portion of Dyer Drive. Additional development and intensification must be
completed prior to Hyde Park Road becoming an urbanized arterial road. The development of the subject
lands will contribute to this process through its site works, design, massing, residential population, and tax
and development charge revenues.
The intersection of Hyde Park Road and Dyer Drive is a full-turns intersection, although only a small
portion of Dyer Drive has been constructed to provide access to the adjacent fire station
1.5.1 Community Context (400m) – Figure 7
The lands within the 400m Community Context area are bisected by Hyde Park Road, and extend to just
south of Fanshawe Park Road. The lands to the west and north of the subject lands are dominated by
agricultural uses, with several rural residential and highway commercial properties along Hyde Park Road
to the northwest of the subject lands. Lands to the west are outside the City of London Urban Growth
Boundary. A fire station lies adjacent to the north of the subject lands on the opposite side of Dyer Drive.
Lands to the east are intended for future medium density residential development and will have access to
Dyer Drive. The full construction of Dyer Drive will link Hyde Park Road and Tokala Trail. A large Regional
Commercial Node, including a home improvement store (Lowe’s) and other stand alone retail stores and
restaurants, lies to the south and southwest of the subject lands along the north side of Fanshawe Park
Road. Only 2 sidewalks exist within 400m of the subject lands, being along the north and south sides of
Fanshawe Park Road.
The built environment along Hyde Park Road, north of Fanshawe Park Road, is largely undeveloped with
only the following features:
Restaurant and reception hall at the northwest corner of Hyde Park Road and Fanshawe Park
Road;
A stormwater management pond at the northeast corner of Hyde Park Road and Fanshawe Park
Road;
Agricultural lands along the west side of Hyde Park Road;
A fire station adjacent to the north of the subject lands;
A pocket of rural, single-detached homes on the west side of Hyde Park Road (north of the
subject lands); and
Agricultural lands on the east side of Hyde Park Road, north of the fire station.
1.5.2 Community Context (800m) – Figure 7
Within the 800m radius, the community context expands to include additional commercial and
industrial/commercial lands on the south side of Fanshawe Park Road. The existing Regional Commercial
Node east of Hyde Park Road includes large format retailers, such as Wal-Mart, Canadian Tire,
Urban Design Brief Old Oak Properties 2179-2201 Hyde Park Road
Page | 8 Zelinka Priamo Ltd.
Homesense, and Future Shop, along with many smaller stores in multi-unit buildings. An established
commercial/industrial park lies at the southwest quadrant of Hyde Park Road and Fanshawe Park Road,
including uses such as pool and spa sales, truss fabrication, and commercial recreation. Built form in this
area is largely one-storey buildings set back from the road with outdoor storage areas located to the side
and rear of existing buildings
In addition to the sidewalks along Fanshawe Park Road, there is an existing sidewalk along the east side
of Hyde Park Road south of Fanshawe Park Road, which extends to beyond Gainsborough Road to the
south.
Also within the 800m radius lies St. Andre Bassette Catholic Secondary School and a developing
residential area along Tokala Trail to the east of the subject lands. These lands are intended to be
developed for single detached dwellings in proximity to other medium density residential lands within
400m of the subject lands.
1.6 SWOT Analysis
An analysis of the strengths, weakness, opportunities and threats presented by the combination of the
neighbourhood context and the proposal, can be summarized as:
Strengths
The proposed development provides an attractive entrance feature at the north limit of the City
The subject lands are designated for High-Density Multi-Family development
The proposed development is compatible with the area context
The subject lands are a large, undeveloped and underutilized parcel of land
The subject lands are in a highly visible location
The subject lands are located on an important arterial road
Within easy walking distance to commercial uses to the south
Within easy walking distance of the parks and trails located in the Fox Hollow Community to the
east
Minimal shadow impact on surrounding lands
The site is fully serviceable
Weaknesses
No weaknesses for this site
Opportunities
Provide residential accommodations in a developing area of the City
Urban Design Brief Old Oak Properties 2179-2201 Hyde Park Road
Page | 9 Zelinka Priamo Ltd.
Implement the intentions of the Official Plan
Promote increased pedestrian activity by having high-density residential development on an
arterial road
Encourage and support future public transit on Hyde Park Road and Fanshawe Park Road
Provide an appropriate formal street presence and an enhanced streetscape along Hyde Park
Road and Dyer Drive
Provide a new visual landmark and gateway feature to the City of London
Locate parking unobtrusively
Threats
The location and context of the subject lands do not pose any threats to the proposed
development.
1.7 Conclusions
The proposed development is consistent with the vision for the future development of this area and will
support the evolution of Hyde Park Road and Dyer Drive as an urbanized environment. The location of
the subject lands at the intersection of Hyde Park Road and Dyer Drive provides an appropriate location
and an optimum opportunity to make a meaningful contribution to both streetscapes and the surrounding
area.
The Neighbourhood Character Statement confirms that the proposed development respects the existing
neighbourhood as follows:
The subject lands have already been deemed appropriate for high density development in a high-
rise form.
The adjacent commercial development will not be adversely impacted by the proposed
development; indeed proximate high density populations will support the continued success of
these developments.
The proposed apartment buildings are oriented to and clearly address the street in a fashion that
is consistent with the development of an urban environment as is possible given the specific
constraints of the site and traffic restrictions with regard to Hyde Park Road.
Urban Design Brief Old Oak Properties 2179-2201 Hyde Park Road
Page | 10 Zelinka Priamo Ltd.
The site plan for the proposed development locates parking and servicing at the rear internal
corner of the development and screens the proposed parking through building placement and
sloped landscaping.
The curbless urban forecourt has been designed to run along the front of the apartment buildings
to provide easy access to the front doors of both buildings. This forecourt has been designed to
reflect a similar strategy as that used in the design of “Naked Streets”.
The Compatibility Report also confirms that the proposed development is compatible with the surrounding
neighbourhood, given that it incorporates the following key features:
Anchors the proposed development into the streetscape and the urban fabric of this evolving
neighbourhood, the proposed development has been designed to address both streetscapes and
the intersection.
Provides upper floors that have been terraced back from the adjacent low-rise neighbourhood to
the south. The massing of the ends of the south elevations have been stepped back at the 15th
and 16th floor to visually soften the profile of the buildings. The 3 and 4 storey podiums work
together with the stepped back massing to soften the building at street level and create a positive
and visually interesting built form.
The colours and finishes of the exterior material, including architectural stone elements, will be
selected to both benefit the design qualities of the proposed buildings and to promote visual
compatibility with the neighbourhood.
Urban Design Brief Old Oak Properties 2179-2201 Hyde Park Road
Page | 11 Zelinka Priamo Ltd.
SECTION 2 – Design Principles and Design Responses
2.1 Conceptual Design
The proposed development offers many of the desirable design elements of the existing residential
development at 885 Southdale Road. For illustration and reference purposes, images of that development
are included in this report. It is intended that the proposed buildings will feature similar, if not identical,
cladding and architectural treatments.
The proposed apartment buildings are to be oriented to address both the Hyde Park Road and Dyer Drive
streetscapes (Figures 6, 9-11). The proposed buildings are located approximately 18.8m from the
ultimate Hyde Park Road right-of-way and approximately 14.5m from the Dyer Drive right-of-way. The
setback from Hyde Park Road is due to a combination of constraints that include the provision of
accessible parking in front of the building and the required internal fire route. While these constraints have
moved the proposed buildings back from the street line, they have provided the opportunity for an
enhanced landscaped treatment along the streetscape and to create a curbless urban forecourt following
a design strategy similar to a “Naked Streets” approach.
Building “A” located at the intersection of Hyde Park Road and Dyer Drive has been configured to clearly
address the intersection with its massing and design as well as the positioning of its lobby to face the
intersection (reference 885 Southdale Road in Figures 12-14). Building “B” has been configured to
position its front doors and lobby to face the Hyde Park Road frontage. Building “C” is positioned in the
northeast corner of the property with its main entrance facing the Dyer Drive frontage. These locations
for the proposed apartment buildings have the benefit of providing a strong street presence while moving
windows away from the adjacent future residential uses to the west.
In plan, the foot prints of the proposed apartment buildings are “L” shaped with their lobbies and elevator
cores located at the junctions of the arms to “L”. Each building has a maximum of 16 habitable storeys
and are terraced to 14 and 15 storeys at their ends. The tallest portions of both buildings are associated
with the outside corner of the “L”. These corner areas are intended to act as the focus for the massing of
the buildings and have a raised roofline that encloses and integrates the mechanical areas of the
buildings. These corners are further punctuated by the presence of curved balconies on the floors above
the lobbies. At the lower floors, these balconies help to define the location of front doors and lobbies.
All the elevations of the proposed buildings have been vertically divided by a series of projecting bays,
balconies, changes in colour and materials. The elevations and the massing of the proposed apartment
buildings are clearly divided into a base, middle, and cap. These divisions have been accomplished
through the use of terracing and cornice lines, as well as changes in materials, fenestration, and colour.
The first three floors and strategic portions of the fourth floors have been designed to create a podium on
Urban Design Brief Old Oak Properties 2179-2201 Hyde Park Road
Page | 12 Zelinka Priamo Ltd.
the base of each building and will be clad with architectural stone. The upper floors will be concrete with a
painted finish of two colours that will be selected to be complementary to the stone colour and that will
assist in providing tonal definition to specific areas of the elevations. Landscaped roof terraces are
located on the 15th floor ends of the “L” adjacent to Hyde Park Road and Dyer Drive. The completed
residential building at Southdale Road and Pomeroy Lane serves as a reference for the cladding,
fenestration, and articulation of the proposed apartment buildings, as can been seen in Figures 11-14.
The ground floors of both buildings will contain residential units facing onto both Hyde Park Road and
Dyer Drive. These units are at the same level as the paved forecourt that provides a shared pedestrian
and vehicular travel surface. Each of these ground floor units are proposed to have doors to the outside
and modest individual outdoor seating areas defined by landscape elements. The forecourt is intended to
provide an attractive calm pedestrian environment as well as the opportunity for vehicles to safely drop off
passengers or make deliveries at front entrances of the proposed buildings, and to facilitate limited visitor
parking. Multiple pedestrian walkways have been positioned adjacent to the buildings and across the
outdoor amenity area to facilitate barrier-free internal movement. To provide visual punctuation and traffic
calming, raised landscaped planters have been shown in the driveways and turn-around areas in front of
each of the main entrances.
The landscape plan (Figure 8) shows the conceptual design of the forecourt and the outdoor amenity
area with its pond, fountains, pergolas, and seating. The edge of the Dyer Drive streetscape will be
planted with shade trees and broken with planted areas, and will also include pergola structures opposite
the main entrances to the buildings (as is provided at 885 Southdale Road). Short sections of low
decorative fencing are proposed to be incorporated into the three planted areas along the streetscape.
The southerly lot line will incorporate trees, plantings, and a 1.8m high solid board fence to screen the
adjacent commercial driveway and loading area. The easterly edge of the proposed development is
shown with a closely spaced line of trees to help screen the parking garage and lower floors of the
apartment building from the adjacent future residential development to the east.
Vehicular access to the site is proposed to be provided by an all-turn connection to Dyer Drive located
centrally along the Dyer Drive frontage and by a secondary all-turn access onto Dyer Drive to the west of
the main entrance. Some convenience parking for visitors and deliveries is located between the Hyde
Park road allowance and the buildings, while parking for residents and longer term visitors will be
provided in a parking structure located to the southwesterly corner of the site and screened from the
public view. This compact parking structure incorporates a landscaped slope along the northerly elevation
for additional screening, and is proposed to contain 287 parking spaces on the raised level. Access to the
upper parking deck is provided at one location along the southerly elevation. Access to the surface space
under the parking deck is provided along the north, south, and west elevations. The upper level is open to
Urban Design Brief Old Oak Properties 2179-2201 Hyde Park Road
Page | 13 Zelinka Priamo Ltd.
the air and will incorporate planters for trees and vegetation. Smaller surface parking areas are located
behind the buildings and will also be screened from public view.
2.2 Public Realm
The site plan proposes the creation of a decoratively-paved curbless urban forecourt that will run the
length of the Hyde Park Road and a portion of the Dyer Drive street frontages, providing pedestrian
access between buildings as well as access to visitor parking and the future public sidewalks along Hyde
Park Road and Dyer Drive. Portions of this paved area are depressed below street level, and plantings
have been used to assist in visually blending the grade differences. It is intended that this publicly
accessible linear forecourt will assist visually and functionally in compensating for the inability of neither
Hyde Park Road nor Dyer Drive to provide a lay-by, street parking, or temporary loading areas that would
promote the use of the front doors facing the street.
2.3 Sustainability Techniques
Although the detailed architectural and engineering designs for these buildings have not yet been
undertaken, as part of the business plans for these rental units, the applicant will pursue energy
conservation as a cost control measure. It is anticipated that the final architectural and engineering
designs for this building will incorporate the following sustainable design features:
Light coloured non-heat absorbing roofing finishes to reduce heat island effect;
Water efficient landscaping;
Energy savings through the use of efficient building systems;
Storage and collection areas for recycling; and
Increase natural ventilation effectiveness.
Urban Design Brief Old Oak Properties 2179-2201 Hyde Park Road
Page | 14 Zelinka Priamo Ltd.
Appendix A
Neighbourhood Character Statement
2179-2201 Hyde Park Road
Old Oak Properties
Neighbourhood Character Statement
The subject lands are made up of two separate parcels, 2179 and 2201 Hyde Park Road. Collectively,
the subject lands form the southeast corner of the intersection of Hyde Park Road and Dyer Drive with
160 m (525 ft) of frontage along Hyde Park Road and 245 m (804 ft) of frontage along Dyer Drive. The
subject lands are currently vacant, but were until recently occupied by a landscape supply business.
Topographically, the subject lands are generally flat and have no significant vegetation on the site. This
site provides the opportunity to establish a strong positive precedent for this section of Hyde Park Road
and a gateway feature at the northwest entrance to the City of London.
Character and Image:
This section of Hyde Park Road is in transition from its role as rural road at the geographic limits of
development to an urban arterial road. The lands to the south of the subject lands are dominated by
commercial development that forms a Regional Commercial Node in the Hyde Park community. The
commercial node to the east of Hyde Park Road (on both sides of Fanshawe Park Road) is made up of
‘big box’ style commercial establishments including a Wal-Mart, Canadian Tire, Homesense, and Future
Shop, as well as other multi-unit commercial buildings. Buildings in this area are placed closer to the
street edge with parking areas between the building and the roadway. Public sidewalks line both sides of
Fanshawe Park Road. To the west of Hyde Park Road, the commercial development includes
restaurants, auto oriented commercial establishments, and landscape supply establishments. Buildings
are set back from Fanshawe Park Road, and no sidewalks exist on either side of the street.
Both sides of Hyde Park Road north of Fanshawe Park Road are largely undeveloped. The west of Hyde
Park Road is dominated by agricultural uses (field cultivation) with several rural single detached dwellings
with mature trees to the northwest of the subject lands. A restaurant and reception hall lies at the
northwest corner of Fanshawe Park Road and Hyde Park Road. A vacant lot with an abandoned parking
area abuts the restaurant to the north. A stormwater management pond lies at the northeast corner of
Hyde Park Road and Fanshawe Park Road with the driveway for the Lowe’s home improvement store
further to the north, abutting the subject lands to the south. This arrangement leaves a large area on the
Urban Design Brief Old Oak Properties 2179-2201 Hyde Park Road
Page | 15 Zelinka Priamo Ltd.
east side of Hyde Park Road undeveloped with little pedestrian appeal. Abutting the subject lands to the
north lies a fire station with its driveway on Dyer Drive. Agricultural uses (field cultivation) extend from the
fire station north to Sunningdale Road and beyond.
Only a small segment of Dyer Drive is constructed which acts as a driveway to the fire station adjacent to
the north of the subject lands. It is intended that Dyer Drive will connect to Tokala Trail to the east and
provide access to low and medium density residential areas east of the subject lands.
None of the adjacent lands already developed along this section of Hyde Park Road provide a sufficiently
urban response to assist in the future urbanization of this arterial road. The design of the proposed
development will provide a strong positive precedent for the urbanization of the streetscape.
Site Design:
The proposed design clearly engages its emerging urban context by providing a strong built form
response to both bounding streetscapes and to the intersection through the employment of “L”
shaped buildings with arms along both streets.
The proposed apartment buildings are oriented to and clearly address the street in a fashion that
is as consistent with the development of an urban environment as is possible given the site
constraints and traffic restrictions with regard to Hyde Park Road.
The massing of the proposed buildings places greater visual weight and importance on the
intersection to form a recognizable gateway feature to both the City of London and the future
residential lands to the east.
The proposed urban forecourt running along Dyer Drive with its landscaping and water elements
will establish the first urban landscaping along this section of Dyer Drive.
The adjacent commercial development and future residential neighbourhood will not be adversely
impacted by the proposed development.
Servicing:
Access to the proposed development will be made from an all-turn access with center median on
Dyer Drive centrally located on the Dyer Drive frontage, and a smaller, secondary all-turn access
to the east, also on Dyer Drive. No access is proposed on Hyde Park Road.
Urban Design Brief Old Oak Properties 2179-2201 Hyde Park Road
Page | 16 Zelinka Priamo Ltd.
By positioning structured parking behind the proposed apartment buildings, flanked by the arms
of the “L”s and by building up a landscaped slope, the visual presence of the parking structure
has been greatly diminished and is effectively screened from view from the surrounding
roadways.
Visitor parking is proposed to be located in both the parking structure and smaller surface parking
areas while short-term parking for visitors and deliveries is located adjacent to the buildings.
All garbage and recycling materials will be stored in garbage rooms within the buildings.
Delineated areas for the pick-up of these materials have been provided in landscaped and
screened areas at the rear of the proposed buildings. These areas will be screened by building
massing, grade changes, landscaping, and privacy fencing.
Urban Design Brief Old Oak Properties 2179-2201 Hyde Park Road
Page | 17 Zelinka Priamo Ltd.
Appendix B
Compatibility Report
2179-2201 Hyde Park Road
Old Oak Properties
Compatibility Report
The subject lands are made up of two separate parcels, 2179 and 2201 Hyde Park Road. Collectively,
the subject lands form the southeast corner of the intersection of Hyde Park Road and Dyer Drive with
160 m (525 ft) of frontage along Hyde Park Road and 245 m (804 ft) of frontage along Dyer Drive. The
subject lands are currently vacant, but was until recently occupied by a landscape supply business.
Topographically, the subject lands are generally flat and there is no significant vegetation on the site.
This site provides the opportunity to establish a strong positive precedent for this section of Hyde Park
Road and a gateway feature at the northwest entrance to the City of London. These lands are designated
to accommodate high-density, high-rise residential buildings, and these forms have been deemed to be
compatible with the adjacent land uses.
Built Form Elements:
The proposed apartment buildings have been oriented to face Hyde Park Road, Dyer Drive and
the intersection.
The location and orientation of the massing of the proposed buildings at the northern corners of
the site will eliminate any shadow impact on the adjacent commercial development to the south.
Potential shadow impacts to properties to the north of the site on the other side of Dyer Drive will
be mitigated by distance. Shadow impact to the lands adjacent to the east has been minimized to
the largest extent possible through building placement and the low-rise parking structure.
The proposed buildings have been designed with their front doors and lobbies facing the public
streets, and their massing and detailed designs have been composed to focus attention on the
importance of these locations and to formally address the streets.
A publicly accessible linear urban forecourt has been proposed along the length of the Hyde Park
Road street frontage to visually and functionally compensate for the inability of Hyde Park Road
Urban Design Brief Old Oak Properties 2179-2201 Hyde Park Road
Page | 18 Zelinka Priamo Ltd.
to provide a lay-by, street parking, and temporary loading areas that would promote the use of
front doors facing the street.
Massing and Articulation:
The basic “L” shape of the building footprints has been articulated on all sides with a series of
projecting bays and recesses to visually divide the planes of the elevations into a series of vertical
elements.
The ends of both buildings have been terraced back at the 15th and 16
th floors to soften their
profiles and to direct attention to the massing of the outside corners as the focus of the
compositions.
Architectural Treatment:
All the elevations of the proposed buildings have been vertically divided by a series of projecting
bays, balconies, changes in colour, and in some areas, by changes in materials.
The elevations and the massing of the proposed apartment buildings are clearly divided through
the incorporation of a 3 and 4-storey podium into a base, middle, and cap. These divisions have
been accomplished through the use of terracing and cornice lines, as well as changes in
materials, fenestration, and colour.
The first three floors and strategic portions of the fourth floors will be clad with architectural stone.
The upper floors will be concrete with a painted finish of two colours that will be selected to be
complementary to the stone colour and that will assist in providing tonal definition to specific
areas of the elevations. Landscaped roof terraces are located on the 15th floor ends of the “L”
adjacent to Hyde Park Road and Dyer Drive.
Urban Design Brief Old Oak Properties 2179-2201 Hyde Park Road
Page | 19 Zelinka Priamo Ltd.
Figure 1: Subject lands
Figure 2: Subject lands (looking Southeast from Hyde Park Road)
Urban Design Brief Old Oak Properties 2179-2201 Hyde Park Road
Page | 20 Zelinka Priamo Ltd.
Figure 3: Subject lands (looking Northeast from Hyde Park Road)
Figure 4: Zoning Map
Urban Design Brief Old Oak Properties 2179-2201 Hyde Park Road
Page | 21 Zelinka Priamo Ltd.
Figure 5: City of London Official Plan – Schedule ‘A’ (excerpt)
Figure 6: Proposed Site Plan
Urban Design Brief Old Oak Properties 2179-2201 Hyde Park Road
Page | 22 Zelinka Priamo Ltd.
Figure 7: 400m and 800m land use context
Urban Design Brief Old Oak Properties 2179-2201 Hyde Park Road
Page | 23 Zelinka Priamo Ltd.
Figure 8: Landscape Plan
Urban Design Brief Old Oak Properties 2179-2201 Hyde Park Road
Page | 24 Zelinka Priamo Ltd.
Figure 9: Perspective Renderings
Urban Design Brief Old Oak Properties 2179-2201 Hyde Park Road
Page | 25 Zelinka Priamo Ltd.
Figure 10: Elevation Rendering (looking southeast from Hyde Park Road)
Figure 11: Elevation Rendering (looking northeast from Hyde Park Road)
Urban Design Brief Old Oak Properties 2179-2201 Hyde Park Road
Page | 26 Zelinka Priamo Ltd.
Figure 12: 885 Southdale Road (east elevation, looking west from Pomeroy Lane)
Figure 13: 885 Southdale Road (looking southwest from Pomeroy Lane and Southdale Road)
Urban Design Brief Old Oak Properties 2179-2201 Hyde Park Road
Page | 27 Zelinka Priamo Ltd.
Figure 14: 885 Southdale Road West (north elevation, looking south from Southdale Road)
Figuree 15: 885 Southdale Road West (southerly streetscape along Southdale Road)
Urban Design Brief Old Oak Properties 2179-2201 Hyde Park Road
Page | 28 Zelinka Priamo Ltd.
Figure 16: Building A North Elevation (facing Dyer Drive)
Urban Design Brief Old Oak Properties 2179-2201 Hyde Park Road
Page | 29 Zelinka Priamo Ltd.
Figure 17: Building A East Elevation (facing stormwater management pond)
Urban Design Brief Old Oak Properties 2179-2201 Hyde Park Road
Page | 30 Zelinka Priamo Ltd.
Figure 18: Building A South Elevation (facing Building B)
Urban Design Brief Old Oak Properties 2179-2201 Hyde Park Road
Page | 31 Zelinka Priamo Ltd.
Figure 19: Building A West Elevation (facing Hyde Park Road)
DYER DRIVE
HY
DE
PA
RK
RO
AD
FIRE ROUTE
FIR
E R
OU
TE
FIRE ROUTE
ENTRANCE
FIRE ROUTE
PARKING DECKOVERHEAD
.
.
.
.
GREEN SPACE
ENTRANCE
RAMP UP
ST
AIR
S
ST
AIR
S
ST
AIR
S
BLDG A
BLDG BAPARTMENT BUILDING16 STOREY200 UNIT
APARTMENT BUILDING16 STOREY200 UNIT
BLDG CAPARTMENT BUILDING16 STOREY200 UNIT
STAIRS
EXISTING PROPERTY LINE
BUILDING SETBACK- EXTERIOR SIDE YARD (11.0m)
BU
ILD
ING
SE
TB
AC
K-
RE
AR
YA
RD
(18
.0m
)
BUILDING SETBACK- INTERIORSIDE YARD (18.0m)
PR
OP
ER
TY
LIN
E
PROPERTY LINE
EX
IST
ING
PR
OP
ER
TY
LIN
E
EASEMENT
RO
AD
WID
EN
ING
ROAD WIDENING
STORM WATERMANAGEMENT
POND
4000 6700 5500 5500 6700 5500
EXISTING PROPERTY LINE
PROPOSED PROPERTY LINE
PARKING STRUCTURESIDE YARD SETBACK (4.5m)
PA
RK
ING
ST
RU
CT
UR
ES
ET
BA
CK
RE
AR
(7.0
m)
FIR
E R
OU
TE
APPROX. LOCATIONOF EX. F.H.
NEW F.H.27.3m TO FIREDEPARTMENTCONNECTION
NEW F.H.23.7m TO FIREDEPARTMENTCONNECTION
NEW F.H.FIRE DEPARTMENTCONNECTION
FIRE DEPARTMENTCONNECTION
FIRE DEPARTMENTCONNECTION
EXISTING BUILDING
5500
272 PARKING STALLS @ GRADEUNDER PARKING DECK
STAIRS
SLOPED LANDSCAPE UP TO2ND LEVEL PARKING DECK
.
.
73 PARKING STALLS
5500
7172
16200
10097
2229
5500
6700
5500
1800
5500
6700
5500
5500
6700
5500
1955
5500
6700
5500
30 PARKINGSTALLS
10 PARKINGSTALLS
PARKINGDECKOVERHEAD
PARKING DECKOVERHEAD
6m X 6mDAYLIGHTTRIANGLE
8700
25900
16200
5500
27 PARKINGSTALLS
33 PARKINGSTALLS
BARRIER FREE PATH OF TRAVEL
BARRIER FREE PATH OF TRAVEL
BARRIER FREE PATH OF TRAVEL
NEIGHBOURING PROPERTY ZONING CSA5
NEIGHBOURINGPROPERTYZONING ASA
NEIGHBOURINGPROPERTYZONING NF1
NEIGHBOURINGPROPERTYZONING R5, R6
FR3
FR3FR3
FR3
FR3
FR3
FR3
FR3
FR3
FR3 FR3 FR2
FR1
FR3
FR3
FR3
FR3
FR3
FR3
FR3
FR3
FR1
1.5m CONC. SIDEWALK
1.5m CONC. SIDEWALK
1.5m CONC. SIDEWALK
1.5
m C
ON
C. S
IDE
WA
LK
1.5m CONC. SIDEWALK
2.0m CONC. SIDEWALK
1.5m CONC. SIDEWALK
1.5m CONC. SIDEWALK
2.2m CONC. SIDEWALK
BARRIER FREE & FIRE FIGHTER ENTRANCE
BARRIER FREE & FIRE FIGHTER ENTRANCE
BARRIER FREE & FIRE FIGHTER ENTRANCE
B.F. PARKINGSIGNS
B.F. PARKINGSIGNS
B.F. PARKINGSIGNS
PEDESTRIAN CONNECTIONTO HYDE PARK ROAD
PEDESTRIAN CONNECTIONTO HYDE PARK ROAD
PEDESTRIAN CONNECTIONTO DYER DRIVE
R=750
R=1000
R=750
R=3000
R=15000
R=19500
R=15000
R=2800
R=13000
R=19500
R=15000
R=15000
R=2800
R=13000
R=19500
R=19500
R=8000
R=1000
R=750
6700 5500 5500
R=750
R=1000
R=1000
6400
20002700
7400
BU
ILD
ING
SE
TB
AC
K-
FR
ON
T Y
AR
D (
11
.0m
)
PR
OP
OS
ED
PR
OP
ER
TY
LIN
E
4589 7700
33769 43200 5500 6700 44024
6700
5500 7157 8100 457 8100 457 8100 457 8100 457 8100 17575400457 8100 457 8100 457 8100 7615 8100 457 8100 457 8100 457 8100 457 8100 457 8100 7158 55004589 7700 5500
18900
6400
2000
2700
7400
4589 7700
11000
R=2500
R=750
R=9000
R=19500
R=15000
R=2800
R=13000
R=19500
R=9000
R=750
R=6000
R=9000R=9000
R=1250
PEDESTRIAN CONNECTIONTO DYER DRIVE
R=50000
R=80000
R=50000
R=40000
R=220000
R=9000
R=42000
R=35000
R=20000
1.5m CONC. SIDEWALK
1.5m WIDEASPHALT PATH
1.5m WIDEASHPALT PATH
SEE LANDSCAPE PLAN
SNOWSTORAGE AREA
SNOWSTORAGE
AREA
SNOW STORAGE AREA
SN
OW
ST
OR
AG
E A
RE
A
SNOWSTORAGE AREA
SNOWSTORAGE
10000
1.8m CONC. SIDEWALK 1.8m CONC. SIDEWALK
DROP CURB
DROP CURB
DROP CURB DROP CURB
DROP CURB
DROP CURB
DROPCURB
DROP CURB
DROPCURB
DROP CURB
DROP CURB
DROP CURB
DROP CURB
6700
10800
9600
2000
2700
7400
1299
LOADING
LO
AD
ING
6700
4000
Site Information
Site Data Chart
PART OF LOT 24, CONCESSION 25
MUNICIPAL NO. 3179 AND 2201 HYDE PARK ROAD
CITY OF LONDON, COUNTY OF MIDDLESEX
ZONING: BYLAW NO. Z-1 RESIDNTIAL R-9 ZONE
BUILDING SETBACKS Required Proposed
BUILDING HEIGHT Maximum Proposed
Max Building Height 32m
Max Number of Storeys N/A 16 storeys
Site Breakdown
Building ABuilding BBuilding CParking Garage
Gross Building Area
Building Footprint
Building ABuilding BBuilding CParking Deck
Gross Building Footprint
25,269.63m²
25,269.63m²
25,269.63m²
17,716.52m²
93,525.41m²
Area Required Provided
14,911.0m²
1,648.06m²1,648.06m²1,648.06m²8,437.06m²
13,381.24m²
11,200.66m²
30% MIN.
-
-
-
-
-
GROSS LOT AREA (After road widening)
4.0429 Ha (40,429.22m²)
3.9492 Ha (39,492.9m²)
DENSITY(After Road Widening)
LOT AREA (Before road widening)
UNIT DENSITY
Max. Unit Density150 Units / HectareArea = 3.9509 Ha150 x 3.9509 = 592.64 Units
Maximum
151 Units/Ha
600 Units
Proposed
150 Units/Ha
592 Units
PARKING BREAKDOWN
1.25 parking space per dwelling unitrequired (TOTAL)(3 Buildings x 200 units each)1.25 x 600 units
Barrier-Free
Accessible Parking StallLimited Mobility
10% Surface Parking
Surface: 503Deck: 287Total: 790
9
503
Provided
750
9
75
Required
Minimum
N/A
48m
Total (39,492.9m²) 100%
-
37.75%
30% + 10% MAX.30% + 6.16%=36.16% MAX
28.37%
-
33.88%
Landscape
Hardscape (NOT IncludingSidewalks OR Parking deck)
Front Yard
Exterior Side Yard
Interior Side Yard
Rear Yard
11.0m Min.
11.0m Min.
18.0m Min.
18.0m Min.
18.77m Min.
14.49m Min.
19.40m Min.
21.50m Min.
2179 and 2201 Hyde Park Road, London, Ontario
LOT FRONTAGE (After road widening) 151.6m
BIKE PARKING (0.75 / UNIT) 450 450 INTERNAL
77
SITE
NEW DYER DRIVE ROAD
MAIN BUILDING ENTRANCE
SECONDARY BUILDING ENTRANCE
BUILDING EXIT ONLY
ARCHITECTS INC.
rs m
Do n
ot
sca
le d
raw
ings. C
on
tract
ors
must
check
and
ve
rify
all
dim
ensio
ns
and
re
po
rt a
ny
dis
cre
pan
cies
to t
he A
rchitect
befo
re p
roce
ed
ing
with
th
e w
ork
. A
ll d
ocum
ents
rem
ain
th
e p
ropert
y o
f th
e A
rchitect.
Un
auth
ori
zed
use,
mo
dific
ation,
and/o
r re
pro
du
ctio
n o
f th
ese d
ocum
ents
is
pro
hib
itted
with
out
wri
tten
perm
issio
n.
The C
on
tract
Docu
men
ts w
ere
pre
pa
red b
y th
e C
onsultan
t fo
r th
e a
ccoun
t o
f th
e O
wne
r.T
he
ma
teri
al c
onta
ined
he
rein
reflects
th
e C
onsultan
ts b
est
jud
ge
men
t in
lig
ht
of
the info
rma
tion a
vaila
ble
to h
im a
t th
e t
ime o
f pre
para
tion
An
y u
se w
hic
h a
th
ird
pa
rty
make
s of
the
Co
ntr
act D
ocum
ents
, o
r any r
elia
nce o
n o
r decis
ion
s to
be m
ad
e b
ase
d o
n t
he
m a
re th
e r
espon
sib
ility
of
such
th
ird
part
ies.
T
he C
on
sulta
nt
acce
pts
no
re
spo
nsi
bili
ty f
or
da
mag
es,
if a
ny,
suff
ere
d b
y any th
ird p
art
y as
a r
esu
lt o
f de
cisi
ons
ma
de o
r act
ions
based
on
th
e C
on
tra
ct D
ocu
ments
.
Drawing No.
Status
Drawing Scale
Plot Date / Time
Checked by
Drawn by
Issue Date
Project No
PRELI
MIN
AR
YProject North True North
Revision No.
As indicated
20/08/2014 11:49:28 AM
\\R
D4
40S
RV
\Sh
are
d F
old
ers
\Pro
jects
\130
35
- O
ld O
ak H
yde
Pa
rk\D
RA
WIN
GS
\Re
vit\[D
esig
n D
raw
ings]\1
30
35
_O
ld O
ak-H
yde
Pa
rk_V
5.r
vt
A1.1
RH
2013-11-21
SITE PLAN
2179 & 2201 Hyde Park Rd.
HYDE PARK LONDON
13035
SPA Submission
SW
1 : 5001SITE PLAN
1 : 50
SITE DATA CHART
No. Date Revision
1 2013-11-21 Minor Variance
1 : 2
KEY PLANN.T.S
SIDEWALK
ASPHALT IMPREGNATED0.0125 SLOPE0.0125 SLOPE
DOWN
SLOPE
0.10 THICK CONCRETE
GRANULAR SUB BASE
AT 20' INTERVALS)
45 O
BARS CONTINUOUS
EXPANSION JOINTS
CONCRETE CURB 25 MPA
(GREASE ENDS ACROSS
POURED IN PLACEWITH 2-15M REINFORCING
UNDISTURBED SOIL
FINE $300.00
75 P
BY-LAW 1-96
BLACK LETTERS
ONLYBY PERMIT
- ALL OTHER DIMENSIONS +/-1/16"
- THICKNESS +/- 0.015"
(DISTANCES ARE IN INCHES)
- CIRCLED DIMENSIONS +/-1/16"
TOLERANCES
F.R. 1 INDICATE DIRECTION PROHIBITED PARKING.
DEFINES THE END ZONES OF A FIRE ROUTE
F.R. 3 INDICATE DIRECTION PROHIBITED PARKING.
BETWEEN THE END ZONES OF A FIRE ROUTE
GRADE
8" BOOT FORANCHORING
STANDARDCITY
ALUMINUM
PURPOSES
ALUMINUMBLANK 6
ALUMINUM
RED
REFLECTIVESILVER
NUMBER
COLOUR OFBACK
SIZE AND
COLOUR
TYPE
F.R. 2 INDICATE DIRECTION PROHIBITED PARKING.
DEFINES THE END ZONES OF A FIRE ROUTE
AT LONDON CITY HALL
INFORMATION PURPOSES ONLY. COPLES OF THE CITY'STRAFFIC AND PARKING BY - LAW P.S. 109 ANDTHE CITY SITE PLAN CONTROL BY LAW C.P. - 1213-340ARE AVAILABLE FROM THE CITY CLERKS OFFICE AT ROOM 308
THESE DETAILS ARE PREPARED FOR EASY REFERENCE AND
BACKGROUND
AND ARROWBORDER, BAR
CIRCLE, SPLASH
AND MESSAGE
AND 'P'
NOTE:
0.91
0.91
0.91
SEE PLAN
0.91
0.0500.150.025
0.15
0.12
5
VA
RIE
S
3015
015
450
125
2530
10
300
3530
1-1/4"
7/8"
3/16"
5/32
" R
45/64"1-3/32"
2-1/2"
1-1
/4"
5/32
"
1/8" R
5/32" R
1/8" R
45/64"
5/32
"
3.5
cm
30.0 cm (Typical)
45.0
cm
2.5
cm6.
5
cm
3.5
cm
2.5
cm6.
5
cm
3.00
m M
AX
2.40
m M
IN
0.6m
20.0
cm
HANDICAP ACCESS CURB DETAIL
N.T.S.
FIRE ROUTE SIGNPLATE DETAIL (Fig. 6.2)
FIRE ROUTE SIGN DETAILS
SIGN POST DETAIL (Fig 6.3)
N.T.S.
SUPPORTSBLANKCOLOUR
SIGN MOUNTING DETAIL (Fig 6.4)
BLACK LETTER "P"LEGEND AND BORDER
STROKE
1.5 cm RED REFL.INTERDICTORY
2 cm RED REFL.ANNULAR BAND
WHITE REFL.BACKGROUND
OUTLINE
BLUE REFL.
WHITE REFL.SYMBOL &
BACKGROUND &
BORDER
RAMP DOWN
ST
AIR
S
STAIRS
ST
AIR
SS
TA
IRS
STAIRS
A
B16 STOREY200 UNITAPARTMENT BUILDINGPHASE 1
16 STOREY200 UNITAPARTMENT BUILDINGPHASE 2
C16 STOREY
200 UNITAPARTMENT BUILDING
PHASE 3
SLOPED LANDSCAPE DN TO GRADE
287 PARKING STALLS @ PARKING DECK
ARCHITECTS INC.
rs m
Do
not s
cale
dra
win
gs.
Con
trac
tors
mus
t che
ck a
nd v
erify
all
dim
ensi
ons
and
repo
rt a
ny d
iscr
epan
cies
to th
e A
rchi
tect
bef
ore
proc
eedi
ng w
ith th
e w
ork.
All
docu
men
ts r
emai
n th
e pr
oper
ty o
f the
Arc
hite
ct. U
naut
horiz
ed u
se, m
odifi
catio
n, a
nd/o
r re
prod
uctio
n of
thes
e do
cum
ents
is p
rohi
bitte
d w
ithou
t writ
ten
perm
issi
on.
The
Con
trac
t Doc
umen
ts w
ere
prep
ared
by
the
Con
sulta
nt fo
r th
e ac
coun
t of t
he O
wne
r.T
he m
ater
ial c
onta
ined
her
ein
refle
cts
the
Con
sulta
nts
best
judg
emen
t in
light
of t
he in
form
atio
n av
aila
ble
to h
im a
t the
tim
e of
pre
para
tion
Any
use
whi
ch a
third
par
ty m
akes
of t
he C
ontr
act D
ocum
ents
, or
any
relia
nce
on o
r de
cisi
ons
to b
e m
ade
base
d on
them
are
the
resp
onsi
bilit
y of
suc
h th
ird p
artie
s.
The
Con
sulta
nt a
ccep
ts n
o re
spon
sibi
lity
for
dam
ages
, if a
ny, s
uffe
red
by a
ny th
ird p
arty
as
a re
sult
of d
ecis
ions
mad
e or
act
ions
bas
ed o
n th
e C
ontr
act D
ocum
ents
.
Drawing No.
Status
Drawing Scale
Plot Date / Time
Checked by
Drawn by
Issue Date
Project No
PRELIM
INARY
Project North True North
Revision No.
As indicated
27/08/2014 9:16:17 AM
C:\U
sers
\Rya
n.D
ES
KT
OP
-219
\Doc
umen
ts\1
3035
_Old
Oak
-Hyd
e P
ark_
V5_
rhic
ks.r
vt
A1.2
Checker
2013-11-21
PARKING DECK
2179 & 2201 Hyde Park Rd.HYDE PARK LONDON
13035
SPA Submission
Author
No. Date Revision
1 : 1
CURB AND FIRE ROUTE SIGN DETAILS
1 : 5001 PARKING DECK
FIRE ROUTE
FIR
E R
OU
TE
FIRE ROUTE
ENTRANCE
FIRE ROUTE
PARKING DECK
OVERHEAD
.
.
.
GREEN SPACE
ENTRANCE
RAMP UP
ST
AIR
S
ST
AIR
S
ST
AIR
S
PARKING DECK - PHASE 1
PARKING DECK - PHASE 2
PARKING DECK - PHASE 3
A
B
16 STOREY
200 UNIT
APARTMENT BUILDING
PHASE 1
16 STOREY
200 UNIT
APARTMENT BUILDING
PHASE 2
C
16 STOREY
200 UNIT
APARTMENT BUILDING
PHASE 3
STAIRS
PROPOSED PROPERTY LINE
BUILDING SETBACK- EXTERIOR SIDE YARD (11.0m)
BU
ILD
IN
G S
ET
BA
CK
- R
EA
R Y
AR
D (18.0m
)
PR
OP
ER
TY
LIN
E
PROPERTY LINE
EX
IS
TIN
G P
RO
PE
RT
Y LIN
E
EASEMENT
RO
AD
W
ID
EN
IN
G
ROAD WIDENING
STORM WATER
MANAGEMENT
POND
EXISTING PROPERTY LINE
PR
OP
OS
ED
P
RO
PE
RT
Y LIN
E
PARKING STRUCTURE
SETBACK REAR (7.0m)
FIR
E R
OU
TE
APPROX. LOCATION
OF EX. F.H.
NEW F.H.
NEW F.H.
NEW F.H.
FIRE
DEPARTMENT
CONNECTION
272 PARKING STALLS @ GRADE
UNDER PARKING DECK
STAIRS
73 PARKING STALLS
29 PARKING
STALLS
10 PARKING
STALLS
PARKING
DECKOVERHEAD
PARKING DECK
OVERHEAD
6m X 6m
DAYLIGHT
TRIANGLE
13 PARKING
STALLS
32 PARKING
STALLS
29 PARKING
STALLS
KEY MAP
Basement Level-3.048 m
Level 10.000 m
Level 23.000 m
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Level 36.000 m
Level 49.000 m
Level 512.000 m
Level 615.000 m
Level 718.000 m
Level 821.000 m
Level 924.000 m
Level 1027.000 m
Level 1130.000 m
Level 1233.000 m
Level 1336.000 m
Level 1439.000 m
Level 1542.000 m
ROOF SLAB48.000 m
PENTHOUSE ROOF52.000 m
15
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
6000
52000
48000
4000
1
55 7
464
464
464
464
464
464
464
464
464
464
464
464
464
5
2
3
44
6446
44
44
6446
44
4 6
6 446446444
6 446446444
6 446446444
6 446446444
6 446446444
6 446446444
6 446446444
6 446446444
6 446446444
6 446446444
6 446446444
6 446446444
6 44644644
4
4
4
4
4
4
4
4
4
4
4
4
4
222
2
222
111
2
Level 1645.000 m
444
4 6
6446
44
464
ELEVATION LEGEND
ARCHITECTURAL STONE FINISH
COLOURED CONCRETE - SMOOTH FINISH (COLOUR: T.B.D.)
MECHANICAL PENTHOUSE
GLAZING (SWELLING UNIT)
GLAZING (AMENITY / COMMON AREA)
DOOR (DWELLING UNIT)
DOOR (AMENITY / COMMON AREA)
1
2
3
4
5
6
7
ARCHITECTS
LICENCEEDWARD THOMAS
5572
OF
ON
TA
R
IOASSOCIAT
ION
ARCHITECTS INC.
rs m
Do n
ot
sca
le d
raw
ings. C
ontr
act
ors
must check
and
veri
fy a
ll d
imensio
ns
and
repo
rt a
ny
dis
cre
pa
nci
es
to th
e A
rchitect b
efo
re p
roceed
ing w
ith t
he w
ork
. A
ll docum
ents
rem
ain
the p
rope
rty o
f th
e A
rchite
ct.
Unau
tho
rize
d u
se,
mo
dific
ation
, a
nd
/or
repro
duct
ion
of th
ese
docum
ents
is
pro
hib
ited
witho
ut
wri
tten
pe
rmis
sio
n.
Th
e C
on
tract
Docu
men
ts w
ere
pre
pa
red b
y th
e C
onsultan
t fo
r th
e a
ccoun
t o
f th
e O
wne
r.T
he
ma
teri
al c
onta
ined
he
rein
reflects
th
e C
onsultan
ts b
est
jud
ge
men
t in
lig
ht
of
the info
rma
tion a
vaila
ble
to h
im a
t th
e t
ime o
f pre
para
tion
An
y u
se w
hic
h a
th
ird
pa
rty
make
s of
the
Co
ntr
act D
ocum
ents
, o
r any r
elia
nce o
n o
r decis
ion
s to
be m
ad
e b
ase
d o
n t
he
m a
re th
e r
espon
sib
ility
of
such
th
ird
part
ies.
T
he C
on
sulta
nt
acce
pts
no
re
spo
nsi
bili
ty f
or
da
mag
es,
if a
ny,
suff
ere
d b
y any th
ird p
art
y as
a r
esu
lt o
f de
cisi
ons
ma
de o
r act
ions
based
on
th
e C
on
tra
ct D
ocu
ments
.
Drawing No.
Status
Drawing Scale
Plot Date / Time
Checked by
Drawn by
Issue Date
Project No
Revision No.
As indicated
20/08/2014 11:43:53 AM
C:\U
se
rs\S
RM
Use
r.D
ES
KT
OP
-22
8\D
ocu
men
ts\1
303
5_B
uild
ing
Rem
ode
lled
_m
ke
enie
.rvt
A3.1
RH
2014-08-07
BUILDING A -NORTH ELEVATION
OLD OAK
HYDE PARK
13035
SITE PLANAPPROVAL
SRW
1 : 1252NORTH ELEVATION
No. Date Revision
1 2014-08-08 SITE PLAN APPROVAL
Basement Level-3.048 m
Level 10.000 m
Level 23.000 m
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
Level 36.000 m
Level 49.000 m
Level 512.000 m
Level 615.000 m
Level 718.000 m
Level 821.000 m
Level 924.000 m
Level 1027.000 m
Level 1130.000 m
Level 1233.000 m
Level 1336.000 m
Level 1439.000 m
Level 1542.000 m
ROOF SLAB48.000 m
PENTHOUSE ROOF52.000 m
ABCDEFGHJKLMN Ax
52000
4000
48000
1
444444464
444664464
444664464
444664464
444664464
444664464
444664464
444664464
444664464
444664464
444664464
444664464
444664464
11 11
1
2 22
1
2 22
2
2 2
2
2 2
2
2
66
66
3
WING FRONTING HYDE PARK ROAD NORTH WING
Level 1645.000 m
44
44
46
64
444
66
44
3
ELEVATION LEGEND
ARCHITECTURAL STONE FINISH
COLOURED CONCRETE - SMOOTH FINISH (COLOUR: T.B.D.)
MECHANICAL PENTHOUSE
GLAZING (SWELLING UNIT)
GLAZING (AMENITY / COMMON AREA)
DOOR (DWELLING UNIT)
DOOR (AMENITY / COMMON AREA)
1
2
3
4
5
6
7
ARCHITECTS
LICENCEEDWARD THOMAS
5572
OF
ON
TA
R
IOASSOCIAT
ION
ARCHITECTS INC.
rs m
Do n
ot
sca
le d
raw
ings. C
ontr
act
ors
must check
and
veri
fy a
ll d
imensio
ns
and
repo
rt a
ny
dis
cre
pa
nci
es
to th
e A
rchitect b
efo
re p
roceed
ing w
ith t
he w
ork
. A
ll docum
ents
rem
ain
the p
rope
rty o
f th
e A
rchite
ct.
Unau
tho
rize
d u
se,
mo
dific
ation
, a
nd
/or
repro
duct
ion
of th
ese
docum
ents
is
pro
hib
ited
witho
ut
wri
tten
pe
rmis
sio
n.
Th
e C
on
tract
Docu
men
ts w
ere
pre
pa
red b
y th
e C
onsultan
t fo
r th
e a
ccoun
t o
f th
e O
wne
r.T
he
ma
teri
al c
onta
ined
he
rein
reflects
th
e C
onsultan
ts b
est
jud
ge
men
t in
lig
ht
of
the info
rma
tion a
vaila
ble
to h
im a
t th
e t
ime o
f pre
para
tion
An
y u
se w
hic
h a
th
ird
pa
rty
make
s of
the
Co
ntr
act D
ocum
ents
, o
r any r
elia
nce o
n o
r decis
ion
s to
be m
ad
e b
ase
d o
n t
he
m a
re th
e r
espon
sib
ility
of
such
th
ird
part
ies.
T
he C
on
sulta
nt
acce
pts
no
re
spo
nsi
bili
ty f
or
da
mag
es,
if a
ny,
suff
ere
d b
y any th
ird p
art
y as
a r
esu
lt o
f de
cisi
ons
ma
de o
r act
ions
based
on
th
e C
on
tra
ct D
ocu
ments
.
Drawing No.
Status
Drawing Scale
Plot Date / Time
Checked by
Drawn by
Issue Date
Project No
Revision No.
As indicated
20/08/2014 11:43:56 AM
C:\U
se
rs\S
RM
Use
r.D
ES
KT
OP
-22
8\D
ocu
men
ts\1
303
5_B
uild
ing
Rem
ode
lled
_m
ke
enie
.rvt
A3.2
RH
2014-08-07
BUILDING A -EAST ELEVATION
OLD OAK
HYDE PARK
13035
SITE PLANAPPROVAL
SRW
1 : 1251EAST ELEVATION
No. Date Revision
1 2014-08-08 SITE PLAN APPROVAL
Basement Level-3.048 m
Level 10.000 m
Level 23.000 m
1234567891011121314
Level 36.000 m
Level 49.000 m
Level 512.000 m
Level 615.000 m
Level 718.000 m
Level 821.000 m
Level 924.000 m
Level 1027.000 m
Level 1130.000 m
Level 1233.000 m
Level 1336.000 m
Level 1439.000 m
Level 1542.000 m
ROOF SLAB48.000 m
PENTHOUSE ROOF52.000 m
15
6000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
4000
48000
52000
WEST WING NORTH WING FRONTING DYER DRIVE
Level 1645.000 m
1
4 4 4 4 4 4 4 6 4
4 4 4 6 6 4 4 6 4
4 4 4 6 6 4 4 6 4
4 4 4 6 6 4 4 6 4
4 4 4 6 6 4 4 6 4
4 4 4 6 6 4 4 6 4
4 4 4 6 6 4 4 6 4
4 4 4 6 6 4 4 6 4
4 4 4 6 6 4 4 6 4
4 4 4 6 6 4 4 6 4
4 4 4 6 6 4 4 6 4
4 4 4 6 6 4 4 6 4
4 4 4 6 6 4 4 6 4
1 111
1
222
1
2
22
22
2
22
222
22
6 6
6 6
34 4
4 4
4 6
6 4
4 4 4
6 6
4 4
3
ELEVATION LEGEND
ARCHITECTURAL STONE FINISH
COLOURED CONCRETE - SMOOTH FINISH (COLOUR: T.B.D.)
MECHANICAL PENTHOUSE
GLAZING (SWELLING UNIT)
GLAZING (AMENITY / COMMON AREA)
DOOR (DWELLING UNIT)
DOOR (AMENITY / COMMON AREA)
1
2
3
4
5
6
7
ARCHITECTS
LICENCEEDWARD THOMAS
5572
OF
ON
TA
R
IOASSOCIAT
ION
ARCHITECTS INC.
rs m
Do n
ot
sca
le d
raw
ings. C
ontr
act
ors
must check
and
veri
fy a
ll d
imensio
ns
and
repo
rt a
ny
dis
cre
pa
nci
es
to th
e A
rchitect b
efo
re p
roceed
ing w
ith t
he w
ork
. A
ll docum
ents
rem
ain
the p
rope
rty o
f th
e A
rchite
ct.
Unau
tho
rize
d u
se,
mo
dific
ation
, a
nd
/or
repro
duct
ion
of th
ese
docum
ents
is
pro
hib
ited
witho
ut
wri
tten
pe
rmis
sio
n.
Th
e C
on
tract
Docu
men
ts w
ere
pre
pa
red b
y th
e C
onsultan
t fo
r th
e a
ccoun
t o
f th
e O
wne
r.T
he
ma
teri
al c
onta
ined
he
rein
reflects
th
e C
onsultan
ts b
est
jud
ge
men
t in
lig
ht
of
the info
rma
tion a
vaila
ble
to h
im a
t th
e t
ime o
f pre
para
tion
An
y u
se w
hic
h a
th
ird
pa
rty
make
s of
the
Co
ntr
act D
ocum
ents
, o
r any r
elia
nce o
n o
r decis
ion
s to
be m
ad
e b
ase
d o
n t
he
m a
re th
e r
espon
sib
ility
of
such
th
ird
part
ies.
T
he C
on
sulta
nt
acce
pts
no
re
spo
nsi
bili
ty f
or
da
mag
es,
if a
ny,
suff
ere
d b
y any th
ird p
art
y as
a r
esu
lt o
f de
cisi
ons
ma
de o
r act
ions
based
on
th
e C
on
tra
ct D
ocu
ments
.
Drawing No.
Status
Drawing Scale
Plot Date / Time
Checked by
Drawn by
Issue Date
Project No
Revision No.
As indicated
20/08/2014 11:43:58 AM
C:\U
se
rs\S
RM
Use
r.D
ES
KT
OP
-22
8\D
ocu
men
ts\1
303
5_B
uild
ing
Rem
ode
lled
_m
ke
enie
.rvt
A3.3
RH
2014-08-07
BUILDING A -SOUTH ELEVATION
OLD OAK
HYDE PARK
13035
SITE PLANAPPROVAL
SRW
1 : 1251SOUTH ELEVATION
No. Date Revision
1 2014-08-08 SITE PLAN APPROVAL
Basement Level-3.048 m
Level 10.000 m
Level 23.000 m
6000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
Level 36.000 m
Level 49.000 m
Level 512.000 m
Level 615.000 m
Level 718.000 m
Level 821.000 m
Level 924.000 m
Level 1027.000 m
Level 1130.000 m
Level 1233.000 m
Level 1336.000 m
Level 1439.000 m
Level 1542.000 m
ROOF SLAB48.000 m
PENTHOUSE ROOF52.000 m
A B C D E F G H J K L M NAx
4000
48000
52000
1
5 57
4 6 4
4 6 4
4 6 4
4 6 4
4 6 4
4 6 4
4 6 4
4 6 4
4 6 4
4 6 4
4 6 4
4 6 4
4 6 4
5
2
3
4 4
6 4 4 6
4 4
4 4
6 4 4 6
4 4
64 4 6 4 4 6 4 4 4
64 4 6 4 4 6 4 4 4
64 4 6 4 4 6 4 4 4
64 4 6 4 4 6 4 4 4
64 4 6 4 4 6 4 4 4
64 4 6 4 4 6 4 4 4
64 4 6 4 4 6 4 4 4
64 4 6 4 4 6 4 4 4
64 4 6 4 4 6 4 4 4
64 4 6 4 4 6 4 4 4
64 4 6 4 4 6 4 4 4
64 4 6 4 4 6 4 4 4
64 4 6 4 4 6 4 4
4
4
4
4
4
4
4
4
4
4
4
4
4
2
2 2
2
2 2
2
1
1 1
2
2
Level 1645.000 m
46
4 6 4
4 4
6 4 4 6
4 4 64 4
ELEVATION LEGEND
ARCHITECTURAL STONE FINISH
COLOURED CONCRETE - SMOOTH FINISH (COLOUR: T.B.D.)
MECHANICAL PENTHOUSE
GLAZING (SWELLING UNIT)
GLAZING (AMENITY / COMMON AREA)
DOOR (DWELLING UNIT)
DOOR (AMENITY / COMMON AREA)
1
2
3
4
5
6
7
ARCHITECTS
LICENCEEDWARD THOMAS
5572
OF
ON
TA
R
IOASSOCIAT
ION
ARCHITECTS INC.
rs m
Do n
ot
sca
le d
raw
ings. C
ontr
act
ors
must check
and
veri
fy a
ll d
imensio
ns
and
repo
rt a
ny
dis
cre
pa
nci
es
to th
e A
rchitect b
efo
re p
roceed
ing w
ith t
he w
ork
. A
ll docum
ents
rem
ain
the p
rope
rty o
f th
e A
rchite
ct.
Unau
tho
rize
d u
se,
mo
dific
ation
, a
nd
/or
repro
duct
ion
of th
ese
docum
ents
is
pro
hib
ited
witho
ut
wri
tten
pe
rmis
sio
n.
Th
e C
on
tract
Docu
men
ts w
ere
pre
pa
red b
y th
e C
onsultan
t fo
r th
e a
ccoun
t o
f th
e O
wne
r.T
he
ma
teri
al c
onta
ined
he
rein
reflects
th
e C
onsultan
ts b
est
jud
ge
men
t in
lig
ht
of
the info
rma
tion a
vaila
ble
to h
im a
t th
e t
ime o
f pre
para
tion
An
y u
se w
hic
h a
th
ird
pa
rty
make
s of
the
Co
ntr
act D
ocum
ents
, o
r any r
elia
nce o
n o
r decis
ion
s to
be m
ad
e b
ase
d o
n t
he
m a
re th
e r
espon
sib
ility
of
such
th
ird
part
ies.
T
he C
on
sulta
nt
acce
pts
no
re
spo
nsi
bili
ty f
or
da
mag
es,
if a
ny,
suff
ere
d b
y any th
ird p
art
y as
a r
esu
lt o
f de
cisi
ons
ma
de o
r act
ions
based
on
th
e C
on
tra
ct D
ocu
ments
.
Drawing No.
Status
Drawing Scale
Plot Date / Time
Checked by
Drawn by
Issue Date
Project No
Revision No.
As indicated
20/08/2014 11:44:03 AM
C:\U
se
rs\S
RM
Use
r.D
ES
KT
OP
-22
8\D
ocu
men
ts\1
303
5_B
uild
ing
Rem
ode
lled
_m
ke
enie
.rvt
A3.4
Checker
2014-08-07
BUILDING A -WEST ELEVATION
OLD OAK
HYDE PARK
13035
SITE PLANAPPROVAL
Author
1 : 1251WEST ELEVATION
No. Date Revision
1 2014-08-08 SITE PLAN APPROVAL
27/08/2014 5:12:29 PM
SITE VIEWSHYDE PARK LONDON
SITE VIEW - NORTHWEST
SITE VIEW - SOUTHWEST
SITE VIEW - NORTHEAST
SITE VIEW - SOUTHEAST
HYDE PARK ROAD
DYER DRIVE
DYER DRIVE
HYD
E P
ARK R
OAD
DYER DRIVE
HYD
E P
ARK R
OAD
HYDE PARK ROAD
DYE
R D
RIV
E
FANSHAWE PARK ROAD WEST
FANSHAWE PARK ROAD WEST