unit heaters

8
> Ventilation Air Conditioning Refrigeration Heating 22 º C Inside OUTSIDE HUMIDITY PROVIDED BY HEINEN & HOPMAN 35 C 90% PRODUCTS Unit heaters

Upload: heinen-hopman

Post on 12-Jan-2017

159 views

Category:

Engineering


2 download

TRANSCRIPT

Page 1: Unit Heaters

>

Ventilation Air Conditioning RefrigerationHeating

22ºCInside

OUTSIDEHUMIDITY

PROVIDED BYHEINEN & HOPMAN

35 C

90%

productsunit heaters

Page 2: Unit Heaters

unit heaters

unit heatersThe unit heaters are primary used to heat large spaces outside the accommodation like workshops, engine room, etc. The heating is done by hot-air supply through a heating coil.

There are different types of heating units: Electrical heating unit: VLE heating units are mainly used in rough environments where boiler water is not available. The heating units are available from 3 kW to 36 kW.

Explosion-proof electrical heating unit: FE2 heating units are ATEX certified unit heaters, specially developed for Ex II and EX IIB zone. The heating units are available from 2.5 kW to 23.1 kW.

Hot-water heating unit: TGA heating units are the most common heating units used offshore and on board ships. The hot water from the boiler acts as heating medium. Steam can also be used as heating medium for higher efficiency. The heating units are available from 8.1 kW to 100 kW.

Thermal-oil heating unit: Thermal-oil heating units are functionally similar to hot-water heating units. The heating units are mainly used in areas with extremely low temperatures. Thermal oil acts as heating medium. Thermal oil has a low freezing point and a high temperature limit up to 400 °C.

Portable heating unit: Delta electrical heating units are easily movable and can be mounted to the wall with brackets for permanent installation. The heating units are available from 3 kW to 21 kW.

Page 3: Unit Heaters

Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.

VLe unit heaters The VLE electrical fan heaters are designed for rough environments e.g. on ships, offshore, in workshops and large production areas.The heaters are available in three standard types: VLE-4, VLE-5 and VLE-6. The heaters are available in galvanized steel, but can also be supplied in different materials (on customer request).The heaters have a built-in thermostat (0-40 °C) which ensures optimal operation and minimizes the energy consumption. The heaters have a thermal fuse that turns off the heater at 110 °C.

Heating elementThe heaters have an electric tube heating element made of stainless steel (AISI304).

Standard versionThe heaters are supplied in 3 x 440V (AC) or 3 x 400V (AC), but very often applications require different voltages. All types are available from 230V to 3 x 690V, with output from 1.2 kW to 150 kW. Safety class IP44.

InstallationThe heaters can be mounted on the wall or ceiling (horizontally or vertically).

Capacity

VLE - 4Range 1.2 kW ~ 12.5 kW

Power3ph / 440V / 60Hz 3ph / 400V / 50Hz

(3 kW available in 230 V)

Dimension 610 x 460 x 560 (mm)

Air quantity 1440 m3/h

Sound level 75dB(A)

VLE - 5

Range 16.5 kW ~ 25 kW

Power 3ph / 440V / 60Hz 3ph / 400V / 50Hz

Dimension 710 x 660 x 670 (mm)

Air quantity 2520 m3/h

Sound level 75dB(A)

VLE - 6

Range 30.5 kW ~ 36 kW

Power 3ph / 440V / 60Hz 3ph / 400V / 50Hz

Dimension 910 x 660 x 760 (mm)

Air quantity 3960 m3/h

Sound level 75dB(A)

Page 4: Unit Heaters

Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.

Fe2 unit heaters FE2 electrical fan heaters are CE-marked & ATEX-approved for use in hazardous areas. The heaters are designed for locations where specific explosive gases or dust may be present.

The heaters use the Vacucore. The induced vacuum within the sealed core provides greater efficiency, distribution of heat across the face of the exchanger and a faster warm-up. If necessary, the entire core can be safely and easily replaced with a new exchanger or core.

The heaters are ATEX Approved (directive 94/9/EC) and Ex II 2 G, Ex d IIB T3 Gb-certified.

Heating elementThe heater core assembly has a sturdy, epoxy-coated, 14-gauge steel cabinet which carries the motor and fan assembly. Adjustable louvers allow directional control of the air flow. All fasteners are zinc-plated for corrosion protection.

Standard versionThe heaters are supplied in 50 Hz or 60 Hz. All types are available from 1 x 220V to 3 x 440V.

InstallationThe heaters can be mounted on the wall or ceiling (horizontally or vertically). Mounting kits are available on request.Mounting kits are made of steel with a wet-applied enamel paint. If the heater is installed on a structure that must be transported, provide additional support for the heater during transport. The suspended weight must not exceed 300 lbs (136 kg).

Page 5: Unit Heaters

specification for 50 hz Models

specification for 60 hz Models

Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.

Model Voltage Nominal wattage

Phase

FE2-220160-025 FE2-220160-042 FE2-220160-063 FE2-220160-084 FE2-220160-126

220 V 220 V 220 V 220 V 220 V

2.5 kW 4.2 kW 6.3 kW 8.4 kW 12.6 kW

1 1 1 1 1

FE2-230160-028 FE2-230160-046 FE2-230160-069 FE2-230160-092 FE2-230160-138

230 V 230 V 230 V 230 V 230 V

2.8 kW 4.6 kW 6.9 kW 9.2 kW 13.8 kW

1 1 1 1 1

FE2-240160-030 FE2-240160-050 FE2-240160-075 FE2-240160-100 FE2-240160-150

240 V 240 V 240 V 240 V 240 V

3.0 kW 5.0 kW 7.5 kW 10.0 kW 15.0 kW

1 1 1 1 1

FE2-440360-042 FE2-440360-084 FE2-440360-168 FE2-440360-210

440 V 440 V 440 V 440 V

4.2 kW 8.4 kW 16.8 kW 21.0 kW

3 3 3 3

FE2-480360-030 FE2-440360-050 FE2-440360-075 FE2-440360-100 FE2-440360-150 FE2-440360-200

480 V 480 V 480 V 480 V 480 V 480 V

3.0 kW 5.0 kW 7.5 kW 10.0 kW 15.0 kW 20.0 kW

3 3 3 3 3 3

Model Voltage Nominal wattage

Phase

FE2-220150-025 FE2-220150-042 FE2-220150-063 FE2-220150-084 FE2-220150-126

220 V 220 V 220 V 220 V 220 V

2.5 kW 4.2 kW 6.3 kW 8.4 kW

12.6 kW

1 1 1 1 1

FE2-230150-028 FE2-230150-046 FE2-230150-069 FE2-230150-138

230 V 230 V 230 V 230 V

2.8 kW 4.6 kW 6.9 kW

13.8 kW

1 1 1 1

FE2-240150-030 FE2-240150-050 FE2-240150-075 FE2-240150-100 FE2-240150-150

240 V 240 V 240 V 240 V 240 V

3.0 kW 5.0 kW 7.5 kW

10.0 kW 15.0 kW

1 1 1 1 1

FE2-380350-025 FE2-380350-042 FE2-380350-063 FE2-380350-084 FE2-380350-125 FE2-380350-167 FE2-380350-209

380 V 380 V 380 V 380 V 380 V 380 V 380 V

2.5 kW 4.2 kW 6.3 kW 8.4 kW

12.5 kW 16.7 kW 20.9 kW

3 3 3 3 3 3 3

FE2-400350-028 FE2-400350-046 FE2-400350-069 FE2-400350-093 FE2-400350-139 FE2-400350-185 FE2-400350-231

400 V 400 V 400 V 400 V 400 V 400 V 400 V

2.8 kW 4.6 kW 6.9 kW 9.3 kW

13.9 kW 18.5 kW 23.1 kW

3 3 3 3 3 3 3

FE2-415350-037 FE2-415350-075 FE2-415350-149 FE2-415350-224

415 V 415 V 415 V 415 V

3.7 kW 7.5 kW

14.9 kW 22.4 kW

3 3 3 3

FE2-440350-042 FE2-440350-084 FE2-440350-168 FE2-440350-210

440 V 440 V 440 V 440 V

4.2 kW 8.4 kW

16.8 kW 21.0 kW

3 3 3 3

Page 6: Unit Heaters

Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.

hot-water unit heaters Hot-water unit heaters are primarily designed for heating of large rooms, workshops or production areas. The TGA 2000 heaters are designed for onshore and offshore objects.The heaters are manufactured in different sizes, with a heating capacity from 8.1 kW to 100 kW and an air flow from 1430 m³/h to 9370 m³/h.

Heating elementThe heaters use the boiler water as heating medium. The air will flow through the heating coil by using a axial or centrifugal fan.The heaters are available with copper tube and aluminum fins, but can also be supplied with stainless-steel casing and galvanized-steel heat exchanger (suitable for rough environments e.g. on ships, offshore).Steam can also be used as heating medium for higher efficiency. The TGA 3000 heaters have a robust steel hot-dip galvanized heating coil, designed for steam heating.

For extremely low temperatures where water/glycol is not applicable, thermal oil can act as heating medium. The TGA 1000 heaters have a robust steel hot-dip galvanized heat exchanger, designed for use with hot water, overheated water or thermal oil.

More information on steam and thermal oil heaters on request.

Standard versionThe heaters have 2-speed motor ventilators. The motors have an externally rotating rotor.• Protection class: IP54• Insulation class: FOn request, special motors, e.g. 3-speed motors, EEx(e) or EEx(d) motors can be mounted. The heaters are available in 1 x 230V, 3 x 230V or 3 x 400V (2-speed or 3-speed).

InstallationThe TGA can be mounted on the wall or ceiling (horizontally or vertically).

Options• Double-sided air grid• Four-sided air grid• Drain (when used for cooling)• 2-speed switch• 5-step switch• Ceiling mounting kit• Wall mounting kit

TGA type Capacity kW (15°C, 70-90°C)

Air quantity m3/h

A mm

B mm

C mm

2300 8,1 - 18,2 1160-1430 450 355 450

2400 11,8 - 27,4 1860-2290 500 395 500

2500 19,1 - 45,5 3250-3850 600 425 600

2600 28,2 - 65,1 4460-5690 700 425 700

2700 41,9 - 100 7450-9370 800 425 800

Page 7: Unit Heaters
Page 8: Unit Heaters

www.heinenhopman.com

Heinen & Hopman encourages a more

sustainable world. By providing eco-friendly solutions and serviceswe offer our clients

the option of reducing energy consumption

and thus co2 emissions. Visit

greenmanifest.info for more information.

BrazilT: +5521 3587 4241/4244E: [email protected]

France - La CiotatT: +334 4204 8685E: [email protected]

France - GrasseT: +336 3090 7786 E: [email protected]

GermanyT:+49 4073 1680E: [email protected]

indiaT: +9133 6499 1293E: [email protected]

italyT: +3901 8745 7970E: [email protected]

the netherlands (hQ)T: +313 3299 2500E: [email protected]

the netherlands (rotterdam)T: +317 8890 8050E: [email protected]

norwayT: +47 6919 0900E: [email protected]

Peoples republic of ChinaT: +8621 3253 2896E: [email protected]

Peoples republic of ChinaT: +86 510 8528 1763E: [email protected]

PolandT: +489 1433 1800E: [email protected]

romaniaT: +402 3644 8222E: [email protected]

russiaT: +7 (4012) 308 801E: [email protected]

singaporeT: +65 6897 7879E: [email protected]

south KoreaT: +8270 4901 0000E: [email protected]

spainT: +349 3225 9668E: [email protected]

swedenT: +46 3121 7500E: [email protected]

turkeyT: +9021 6493 8118E: [email protected]

uae (abu Dhabi) T:+971 2550 4147E: [email protected]

uae (Dubai)T: +971 4263 5453E: [email protected]

usa - Fort Lauderdale, FloridaT: +195 4463 0110E: [email protected]

usa - houma, Louisiana T: +198 5876 7989E: [email protected]