ucs invicta & application performance
DESCRIPTION
What is persistent flash memory and how can it help accelerate applications.TRANSCRIPT
UCS Invicta & Application Performance
Technical Marketing, Solid State Systems Group
April 12, 2023
Cisco Confidential 2© 2013-2014 Cisco and/or its affiliates. All rights reserved.
Speed is the Top Tier
Cisco Confidential 3© 2013-2014 Cisco and/or its affiliates. All rights reserved.
Quickly Add Assets
Rapidly Provision & Re-provision Resources
Applications need infrastructure that deploys faster
Cisco Confidential 4© 2013-2014 Cisco and/or its affiliates. All rights reserved.
UCS Founding Principles
The Unified Computing System deploys infrastructure fast
Servers
UCSNetwork / Storage Access
ApplicationCentric
OperationalSimplicity
Platform for IT Innovation
Cisco Confidential 5© 2013-2014 Cisco and/or its affiliates. All rights reserved.
Benefits of Cisco Unified Computing SystemInnovation serving 30,000 UCS Customers World Wide
Sources: Cisco UCS Changing the Economics of the Datacenter, Customer Case Studies, Cisco UCS Performance Benchmarks
Superior Economics and Operations Superior Performance
90+World-Record
Application Performance Benchmarks
54%
Reduction of Power and
Cooling Costs
61%
Reduction of Ongoing
Management Costs
77%
Reduction of Cabling
84%
Reduction in Provisioning
Times
Cisco Confidential 6© 2013-2014 Cisco and/or its affiliates. All rights reserved.
Fast Application Deployment
Fast Application Execution
Faster Applications need infrastructure that runs faster
Cisco Confidential 7© 2013-2014 Cisco and/or its affiliates. All rights reserved.
Second Millisecond Microsecond Nanosecond0.000000001
0.00000001
0.0000001
0.000001
0.00001
0.0001
0.001
0.01
0.1
1
Response Time
Flash Memory provides a Faster Time Zone for Applications
Slow Zone
Fast Zone
HDD
Flash
CPU
Cisco Confidential 8© 2013-2014 Cisco and/or its affiliates. All rights reserved.
24 HDDs• 4,500 IOP, Milliseconds
24 Hybrid HDDs• 12,750 IOPS, Milliseconds
24 SSDs• 250,000 IOPS• Microseconds
Slow
Faster
Hyper-Fast
Use Case for Flash Memory is Application Speed
Cisco Confidential 9© 2013-2014 Cisco and/or its affiliates. All rights reserved.
UCS + Flash
Cisco Confidential 10© 2013-2014 Cisco and/or its affiliates. All rights reserved.
Flash Memory aligned with compute unifies resource provisioning and enables faster application workloads
Flash Memory Compute Network
UCS
UCS becomes the Fast Lane for Application Workloads
UCS Manager UCS Director
Cisco Confidential 11© 2013-2014 Cisco and/or its affiliates. All rights reserved.
UCS Invicta Series
UCS Invicta Series• Part of the UCS Architecture• Modular Architecture • UCS Management
Integration • Future Fabric Integration
Appliance• Invicta OS
• Media Management, Data Protection & Data Reduction
• Balanced Write/Read Performance
• Converts into Scaling System Node
Scaling System• Invicta OS
• Router Services • Media Management, Data
Protection & Data Reduction
• Efficiency of Scale Up with the Power of Scale Out
• Supports Multiple Workloads
Cisco Confidential 12© 2013-2014 Cisco and/or its affiliates. All rights reserved.
Cisco UCS Invicta Series
Up to 1.2 Million IOPSUp to 7.2 GB/s BandwidthUp to 144 TB RAW *FC & iSCSI
UCS Invicta Appliance
Scalability
Modularity
Application Acceleration
Data Optimization
Multiple Workloads
Tuning-Free Performance
250,000 IOPS1.2 GB/s BandwidthUp to 24 TB RAWFC & iSCSI
UCS InvictaScaling System
*6 node configuration
Cisco Confidential 13© 2013-2014 Cisco and/or its affiliates. All rights reserved.
Invicta OSDesigned to drive the high performance from Flash Media
1. Protect •Store in Write Buffer
2. Organize •Create Write Blocks
3. Optimize •Write Aligned for Flash Media & RAID Protection
Cisco Confidential 14© 2013-2014 Cisco and/or its affiliates. All rights reserved.
Invicta OSOptimizing Flash for Faster Writes & Higher Endurance
4. Optimize Writes•Write speeds are symmetric to read speeds
5. Virtual Garbage Collection•Evaluated and Managed by the Invicta OS
6. Virtual Garbage Collection•Blocks are invalidated in large chunks to speed up drive level garbage collection
Cisco Confidential 15© 2013-2014 Cisco and/or its affiliates. All rights reserved.
Invicta OS
Appliance Management
GUI/APIUCS
Director Support
Flash Management
Write Optimizatio
n
vGarbage Collection
Volume Manageme
nt
Thin Provisioning
Data Management
Snapshots De-Duplication
Data Protection
RAID 6 Replication
UCS Invicta Appliance
Cisco Confidential 16© 2013-2014 Cisco and/or its affiliates. All rights reserved.
UCS Invicta Appliance
Invicta OS Operating Modes
High Performance
IOPS
220,000 100% R
205,000 50/50 R/W
200,000 100% W
Max Capacity
24TB
Data Reduction
IOPS
250,000 100% R
180,000 50/50 R/W
120,000 100% W
Max Effective Capacity
64TB
Cisco Confidential 17© 2013-2014 Cisco and/or its affiliates. All rights reserved.
Scaling ArchitecturesThe Basics
Scale Up• A Storage Array
• Adding Shelf Increases Capacity
• Performance is limited to the power of the Storage Controllers
• Applications share the Controllers
Scale Out• Adding a node increases
capacity, IOPS and throughput
• Applications share the pool • Data is distributed across
the pool to maintain performance
Scale Up / Out• Adding Nodes increases
capacity, IOPS and throughput• Nodes can be organized
into pools of varying sizes, performance, and capabilities .
• Applications are assigned to pools
Cisco Confidential 18© 2013-2014 Cisco and/or its affiliates. All rights reserved.
UCS Invicta Scaling SystemScale Up/Out
Scaling System Routers
Manages connectivity between Hosts and Scaling System Nodes
Supports Multiple node types • Application Acceleration • Data Reduction
Add Nodes to increase performance and capacity
Scaling System Nodes
Application Acceleration Mode orData Reduction Mode
Application Acceleration Mode • 3TB-24TB RAW Capacity per node
Data Reduction Mode• 25TB-64TB Effective Capacity per
node
SSR
SSR
SSN
SSN
SSN
SSN
SSN
SSN
Cisco Confidential 19© 2013-2014 Cisco and/or its affiliates. All rights reserved.
UCS Invicta Scaling SystemDistributed / Separated Architecture
Invicta OS
Scaling System Router
Scaling System Management
UCS Director Support
Host Connectivit
y Node Mgmt
Volume Manageme
nt
Data Protection
Mirroring Replication
Scaling System Node
Flash Mgmt
Write Optimizatio
n
vGG (Garbage
Collection)
Volume Mgmt
Thin Provisionin
g
Data Management
Snapshots De-Duplication
Data Protecti
on
RAID 6
SSR SSN
Cisco Confidential 20© 2013-2014 Cisco and/or its affiliates. All rights reserved.
UCS Invicta Scaling SystemOrganize Pools to meet application requirements
SSN
SSN
SSR
SSN
SSR
SSN
SSN
SSN
Databases
Analytics
Transaction Systems
File Shares
Development Environments
Virtual Desktops
3 Performance Pools• 600,000 IOPS• Raw Pool capacities can
range from 3TB to 24TB
3 Data Reduction Pools • 450,000 IOPS• Effective pool capacities
can range from 25TB to 64TB
Cisco Confidential 21© 2013-2014 Cisco and/or its affiliates. All rights reserved.
UCS Invicta Series Managed by UCS Director
UCS Director
OrchestrationPoliciesService ProfilesSelf-serviceTasksWorkflows
Cisco Confidential 22© 2013-2014 Cisco and/or its affiliates. All rights reserved.
Cisco Management Overview
Manages multiple
UCS Domains
Manages ACI Fabric
UCS CENTRAL
UCS DIRECTOR Centralized infrastructure control point for data center
APIC
INTELLIGENT AUTOMATION FOR CLOUD Private Cloud, PaaS (DevOps), Hybrid Cloud
Manages: UCS Invicta, Nexus, Heterogeneous and Converged infrastructures
Manages Single UCS domain
UCS MANAGER
Cisco Confidential 23© 2013-2014 Cisco and/or its affiliates. All rights reserved.
UCS Invicta SeriesBringing Flash Memory into the UCS Architecture
Invicta OS
V5.x•Flash media management
•Data protection•De-Duplication•UCS Director Support •FCoE
UCS Invicta Series
ApplianceScaling System Storage Blade------•Based upon •UCS C•UCS B
Network
Switched Back PlaneVICFabric Interconnect------Unified Fabric•Lower latency•Higher bandwidth
Management UCS DirectorUCS Manager------•Orchestration•Policies•Service Profiles•Self-service•Tasks•Workflows
Integration Steps
Items in green are completed or in progress
B Serie
s
InvictaSeries
SAN/LANFabric
Interconnect
C Series
UCS
Cisco Confidential 24© 2013-2014 Cisco and/or its affiliates. All rights reserved.
Faster Infrastructure. Faster Applications. Faster Business.
Compute
Network
FlashMemory
UCS
Accelerated Applications
Business Data