tps 50 - panelco · m m) t h i c k n e s s s (m) ... tps 50.1000 is used for roof and wall cladding...
TRANSCRIPT
PANELCOMETAL COMPOSITE PANELS & CONSTRUCTION ELEMENTS
TPS 50.1000ËÁÌÁÑÉÍÁ ÏÑÏÖÇÓ ÊÁÉ ÐËÁÃÉÏÊÁËÕØÇÓ
ROOF AND WALL STEEL SHEETS
FALC
ON
1
34
/ 2
00
.4 /
2ó
ô
P. 1
1/0
7
www.panelco.gr
PANELCOMETAL COMPOSITE PANELS & CONSTRUCTION ELEMENTS
ÅñãïóôÜóéï: ÂÉÐÅ Ëáìßáò, Ï.Ô. 4Â, 35100, Ëáìßá, Ôçë.: 22310-66122-3, Fax: 22310-43771ïÃñáöåßá Íüôéáò ÅëëÜäáò & Åîáãùãþí: 54 ÷ëì. ÅèíéêÞò ïäïý Áèçíþí-Ëáìßáò, ÈÝóç Ëõóßá, 32011, Ïéíüöõôá, Âïéùôßá
Ôçë.: 22620-32200, Fax: 22620-30791Ãñáöåßá Âüñåéáò ÅëëÜäáò: Ðáëáéüêáóôñï, 57200, Ùñáéüêáóôñï, Èåóóáëïíßêç, Ôçë.: 2310-687935, Fax: 2310-687924
Production Plant: Industrial Zone of Lamia, S.B. 4B, 35100, Lamia, GREECE. Tel.:+30 22310-66122-3, Fax: +30 22310-43771thSales Southern Greece and Exports: 54 km Athens-Lamia National Road, Thesi Lisia, 32011, Inofita-Viotia, GREECE
Tel.: +30 22620-32200, Fax: +30 22620-30791Sales Northern Greece: Paleokastro, 57200, Oreokastro-Thessaloniki, GREECE, Tel.: +30 2310-687935, Fax: +30 2310-687924
ÅËÁÓÌÁÔÁ
ÅðéøåõäáñãõñùìÝíïò åí èåñìþ ÷Üëõâáò êáôÜ ÅÍ 10142: 90/ Á1 95, ÅÍ 10147:91/ êáé A1 95 EN 10143, óå ðÜ÷ç áðü 0,40mm Ýùò 0,75mm, ðñïâáììÝíïò ìå ðïëõåóôåñéêÞ âáöÞ 25ì (ÅÍ 10169-1/03).Êáôüðéí åéäéêÞò ðáñáããåëßáò ìðïñïýí åðßóçò íá ÷ñçóéìïðïéçèïýí: á) INOX â) Áëïõìßíéïã) ÃáëâáíéóìÝíïò ÷Üëõâáò ìå åðéêïëëçìÝíï öéëì PVC 150ì Þ ìå âáöÞ PVDF áðü 40ì - 60ì, ùò åðßóçò âáöÞ HDP.
SHEETS
Zinc-coated, hot rolled steel per ÅÍ 10142: 90/ Á1 95,ÅÍ 10147:91/ and A1 95 EN 10143, in thicknesses ranging from 0.40mm to 0.75mm, pre-painted with polyester coating25ì (ÅÍ 10169-1/03).The following can be also used under special agreement: a) INOX b) Aluminium c) Galvanized steel, coated with PVC 150ì film or painted with PVDF 40ì - 60ì, as well as HDP paint.
1,50 1,75 2,00 2,25 2,50 2,75 3,00 3,25 3,50 3,75 4,00
5,00
6,00
7,50
10,00
12,50
ÁÌÖÉÅÑÅÉÓÔÇ ÓÔÇÑÉÎÇ
BOTH END SUPPORT
ÐÁ×ÏÓ S
(m
m)
THICKN
ESS
S (m
m)
ÂÁ
ÑÏ
Ó/Ì
ÅÔÑÏ
WEI
GHT
(kg/m
²)
MULTIPLE SPAN SUPPORT
ÓÔÇÑÉÎÇ ÐÏËËÁÐËÙÍ ÁÍÏÉÃÌÁÔÙÍ
L/200
ÁÍÏÉÃÌÁÔÁ ÔÅÃÉÄÙÍ (m)PURLIN DISTANCE (m)
ÏÌÏÉÏÌÏÑÖÁ ÊÁÔÁÍÅÌÇÌÅÍÏ ÖÏÑÔÉÏ (kg/m²)PERMISSIBLE LOADS (kg/m²)
TPS 50.1000
0.50
0.60
0.75
1.00
1.25
180
260
380
640
930
140
220
300
510
740
115
180
248
412
562
95
148
202
312
395
82
123
162
235
288
72
92
124
174
219
56
72
97
134
168
52
55
78
105
140
36
42
64
85
108
30
40
56
73
90
26
35
42
61
73
0.50
0.60
0.75
1.00
1.25
5,00
6,00
7,50
10,00
12,50
253
412
539
820
1128
185
302
394
602
828
141
229
302
445
595
113
169
221
340
490
85
135
175
290
417
76
110
148
245
350
60
92
128
212
302
55
80
110
184
245
48
70
98
152
195
42
60
85
122
158
37
53
72
100
129
MATERIAL APPLICATIONS -SPECIFICATIONS
TPS 50.1000 is used for roof and wall cladding in constructions requiring no thermal insulation. In addition, it can be used in existing building façade redevelopment, as well as for permanent decking applications. In its perforated type, the specific product can also meet certain sound insulation needs when used in double sheet with inner sound insulation material. The above profile can be produced also in curved shape, for use in cladding buildings of special designs.
ÅÖÁÑÌÏÃÅÓ - ÐÑÏÄÉÁÃÑÁÖÅÓ ÕËÉÊÙÍ
Ôï TPS 50.1000 ÷ñçóéìïðïéåßôáéãéá åðéêáëýøåéò êáé ðëáãéïêáëýøåéò êôéñßùí, óôá ïðïßá äåí áðáéôåßôáé èåñìïìüíùóç. ÅðéðëÝïí ìðïñåß íá ÷ñçóéìïðïéçèåß ãéá äéáìïñöþóåéò üøåùí õöéóôáìÝíùí êôéñßùí ðïõ ÷ñåéÜæïíôáé ðáñåìâÜóåéò, ùò åðßóçò êáé ùò ìüíéìïò ìåôáëëüôõðïò. Ìå ôç äõíáôüôçôá ðáñáãùãÞò ôïõ êáé óå äéÜôñçôç ìïñöÞ êáëýðôåé áíÜãêåò ç÷ïðñïóôáóßáò üôáí ÷ñçóéìïðïéåßôáé äéðëü Ýëáóìá ìå åíäéÜìåóç ç÷ïðñïóôáôåõôéêÞ ìüíùóç.ÔÝëïò óçìåéþíåôáé üôé ôï ðáñáðÜíù ðñïößë ìðïñåß íá ðáñá÷èåß êáé óå êáìðýëç ìïñöÞ äßíïíôáò ôç äõíáôüôçôá íá êáëýðôïõìå êôßñéá åéäéêþí áñ÷éôåêôïíéêþí ëýóåùí.
TPS 50.1000ËÁÌÁÑÉÍÁ ÏÑÏÖÇÓ ÊÁÉ ÐËÁÃÉÏÊÁËÕØÇÓROOF AND WALL STEEL SHEETS
PANELCOMETAL COMPOSITE PANELS & CONSTRUCTION ELEMENTS
1000mm
50mm
54mm
135mm 115mm250mm