tonometry icare tonovet plus - eickemeyer plus_… · tonometry enhanced usability the tonovet plus...

4
TONOMETRY Icare ® TONOVET Plus Quick, easy & precise No calibration No anaesthesia www.eickemeyer.com

Upload: others

Post on 09-Jul-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TONOMETRY Icare TONOVET Plus - Eickemeyer Plus_… · Tonometry enhanced usability The TONOVET Plus tonometer is based on the rebound measuring principle, in which a light weight

TONOMETRYIcare® TONOVET PlusQuick, easy & precise

No calibration

No anaesthesia

www.eickemeyer.com

Page 2: TONOMETRY Icare TONOVET Plus - Eickemeyer Plus_… · Tonometry enhanced usability The TONOVET Plus tonometer is based on the rebound measuring principle, in which a light weight

QUICK, EASY & PRECISE Icare® TONOVET Plus

Tonometry

enhanced usability

The TONOVET Plus tonometer is based on the rebound measuring principle, in which a light weight probe is used to make momentary contact with the cornea. Using the TONOVET Plus is so simple, that results are obtained in less than a minute and patients hardly even notice it.

No calibration

No anaesthesia

“The new functionality of having the light on the tip of the unit and illumination on the cornea helps guide alignment and allows the TONOVET Plus to be used in the dark.”

Settings for four species

Automatic measuring settings for dog, cat, rabbit and horse.

Simplicity

Option to take all six measurements with one press of the button.

Patient friendly

The gentle measurement does not require any anaesthetic, nor does it cause corneal reflex in most animals.

Clear user interface

Bigger display and user-friendly interface with clear messaging

Page 3: TONOMETRY Icare TONOVET Plus - Eickemeyer Plus_… · Tonometry enhanced usability The TONOVET Plus tonometer is based on the rebound measuring principle, in which a light weight

TONOMETRYIcare® TONOVET Plus

Improved accuracy for different species

Automatic measurement sequence option

Positioning assistant lights

Larger display

Measuring support

Easy to use, short learning curve

Short preparation time

Universal AA batteries

2 years warranty

Technical Specifi cations

Display unit: Millimetre of mercury (mmHg)

Measurement range: 10 – 60 mmHg

Accuracy: ± 2,5 mmHg (10 – 30 mmHg) and ± 10 % (> 30 – 60 mmHg)

This device has BF-type electric shock protection

Repeatability (coeffi cient of variation): < 8 %

Accuracy of display: 1 mmHg

Weight: 140 g (without batteries), 230 g (4 x AA batteries)

Dimensions (in mm):L 215 x W 24 – 29 x H 35 – 95

1736007

Automatic measurement sequence

Positioning assistant lights

Measuring support

Easy to use, short learning curve

Short preparation time

Universal AA batteries

Page 4: TONOMETRY Icare TONOVET Plus - Eickemeyer Plus_… · Tonometry enhanced usability The TONOVET Plus tonometer is based on the rebound measuring principle, in which a light weight

EICKEMEYER® | Eltastraße 8 | 78532 Tuttlingen | Germany | T +49 7461 96 580 0 | F +49 7461 96 580 90 | [email protected] | www.eickemeyer.com

STAND FOR TONOVET PLUS

Table and wall mountable

1736008

STAND STAND

12 /

2018

| ph

oto

page

2: ©

Nej

ron

Phot

o –

foto

lia.c

om

ACCESSORIESfor Icare® TONOVET Plus

Tonometry

SILICONE GRIPFOR TONOVET PLUS

Green

E173600703

PROBESFOR TONOVET PLUS

100 per pack

1736006

PROBE BASE COLLARFOR TONOVET PLUS

E173600702

PROBE BASEFOR TONOVET PLUS

E173600701

The new Icare® TONOVET Plus is even easier to use. It features an advanced user interface with a clearer, larger display. Red / green positioning lights help to fi nd the correct angle and aim to the middle of the cornea. After the six measurements the tonometer calculates the fi nal intra ocular pressure (IOP) and stores it in the tonometer’s memory.

TONOVET Plus used on a Labrador