Arterial Tonometry. Preston Broderick, MA University of Pennsylvania. Arterial Tonometry. Non-invasive device used to obtain Pulse Wave Analysis (PWA), Pulse Wave Velocity (PWV) To be performed immediately after the MRI ~30 minute procedure Participant must be laying down - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Arterial Tonometry

ACRIN CV Committee

Arterial Tonometry

Preston Broderick, MA

University of Pennsylvania

Page 2: Arterial Tonometry

ACRIN CV Committee

Arterial Tonometry Non-invasive device used to obtain Pulse

Wave Analysis (PWA), Pulse Wave Velocity (PWV)

To be performed immediately after the MRI ~30 minute procedure Participant must be laying down Do not include PHI in the database

Page 3: Arterial Tonometry

ACRIN CV Committee

Arterial TonometryAdding a subject to the database

Page 4: Arterial Tonometry

ACRIN CV Committee

Arterial Tonometry Information that must be entered

ID First Initial Last Initial Year of Birth Sex

Page 5: Arterial Tonometry

ACRIN CV Committee

Arterial Tonometry

Page 6: Arterial Tonometry

ACRIN CV Committee

Arterial Tonometry Pulse Wave Analysis

Obtain BP measurements using an Omron HEM-907 device

Use that data to calculate the mean arterial pressure with the following equation:

• MAP = DBP + 0.4 (SBP-DBP)

Type the sbp in the notes section as “SBP: x” Indicate which side the radial tonometry is being

performed in the notes section Enter data into PWA subject screen as follows

Page 7: Arterial Tonometry

ACRIN CV Committee

Arterial TonometryPulse Wave Analysis (Radial)

Page 8: Arterial Tonometry

ACRIN CV Committee

Data acquisition Relax your arms and hands Maintain a constant pressure Acquire 12 seconds of data Complete acquisition by pressing the space bar Goal is to achieve good consistency and height in the

waveforms Shoot for as high an operating index as possible

• Ideal target: >90 for radial

• Ideal target: >80 for carotid

Arterial Tonometry

Page 9: Arterial Tonometry

ACRIN CV Committee

Arterial Tonometry

12 Seconds of consistent data acquisition

Page 10: Arterial Tonometry

ACRIN CV Committee

Arterial TonometryFavorable Result: 94 Operator Index

Page 11: Arterial Tonometry

ACRIN CV Committee

Arterial TonometryUnfavorable Result: 0 Operator Index

Page 12: Arterial Tonometry

ACRIN CV Committee

Arterial TonometryPulse Wave Analysis (Carotid)

Page 13: Arterial Tonometry

ACRIN CV Committee

Arterial TonometryPulse Wave Analysis (Carotid)

Page 14: Arterial Tonometry

ACRIN CV Committee

Arterial Tonometry

12 Seconds of consistent data acquisition

Page 15: Arterial Tonometry

ACRIN CV Committee

Arterial TonometryFavorable Result: 95 Operator Index

Page 16: Arterial Tonometry

ACRIN CV Committee

Arterial TonometryUnfavorable Result: 5 Operator Index

Page 17: Arterial Tonometry

ACRIN CV Committee

Arterial Tonometry Pulse Wave Velocity

Measure distance (mm) between carotid artery and sternal notch

Measure distance (mm) between femoral artery and sternal notch

Shoot for lowest standard deviation possible• Ideal target <10% SD

Place ECG electrodes on subject prior to acquisition

Page 18: Arterial Tonometry

ACRIN CV Committee

Arterial TonometryPulse Wave Velocity

Page 19: Arterial Tonometry

ACRIN CV Committee

Arterial TonometryPulse Wave Velocity (Carotid)

12 Seconds of consistent data acquisition

Page 20: Arterial Tonometry

ACRIN CV Committee

Arterial TonometryPulse Wave Velocity

Page 21: Arterial Tonometry

ACRIN CV Committee

Arterial TonometryPulse Wave Velocity (Femoral)

12 Seconds of consistent data acquisition

Page 22: Arterial Tonometry

ACRIN CV Committee

Arterial TonometryFavorable Result: 7% SD

Page 23: Arterial Tonometry

ACRIN CV Committee

Arterial TonometryUnfavorable Result: 13% SD

Page 24: Arterial Tonometry

ACRIN CV Committee

Arterial Tonometry Exporting data from software

This is the data that will be used for analysis Export text file after each study visit Three exports for each visit

• PWA Radial• PWA Carotid• PWV

Choose result with highest operator index to export Keep organized by subject ID, visit number, and result

• 001_B_PWAR• 001_B_PWAC• 001_F_PWV

Page 25: Arterial Tonometry

ACRIN CV Committee

Data Export

Arterial Tonometry

Page 26: Arterial Tonometry

ACRIN CV Committee

Arterial TonometryData Export

Page 27: Arterial Tonometry

ACRIN CV Committee

Arterial TonometryData Export

Page 28: Arterial Tonometry

ACRIN CV Committee

Arterial TonometryData Export

Page 29: Arterial Tonometry

ACRIN CV Committee

Arterial Tonometry Backing up the database

Imperative in case of data loss Backup text files as well as database file Database file located in following location:

C:\Program Files\AtCor\SphygmoCor CvMS\data Filename: scor.xyz

Simply copy/paste file into a location other than C:\ drive Backup database as frequently as possible Rename database file to date it was backed up

Example: scor4008_5-23-2013.xyz