the new reality in blood gas qc tonometry at real sample … · 2019. 1. 10. · tonometry at real...

4
The new reality in Blood Gas QC Tonometry at real sample temperature….

Upload: others

Post on 03-Sep-2020

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: The new reality in Blood Gas QC Tonometry at real sample … · 2019. 1. 10. · Tonometry at real sample temperature…. The new generation of the TM8000 offers active temperature

The new reality in Blood Gas QC

Tonometry at real sample temperature….

Page 2: The new reality in Blood Gas QC Tonometry at real sample … · 2019. 1. 10. · Tonometry at real sample temperature…. The new generation of the TM8000 offers active temperature

The new generation of the TM8000 offers active temperature management

For the first time samples can be tonometered at temperatures from 20,0°C to 39,9°C *

and the actual measured values can be determined at a body – or sample temperature

deviating from 37°C. The temperature corrections implemented in Blood Gas Systems,

which are based on a calculation model, can be determined and adapted with high

accuracy.

Determine the deviation of temperature corrections

Studies have shown that temperature corrections implemented in the Blood Gas

Systems often deviate significantly from the actual values. Depending on the partial

pressure deviations of more than 50% are possible at sample temperatures of 20°C.

With the TM8000flex the exact temperature corrections for different Blood Gas Systems

and applications can be determined.

Typical deviations on various sample – temperatures [Posterproject UKR-Regensburg]

Application examples:

• Cardiac surgery / Surgery:

Determination of the exact temperature correction for the used Blood Gas Analyzer at the

applied patient temperatures

• Manufacturer of Blood Gas Systems:

Simple determination of parameters for the implemented temperature corrections

• Professional Blood Gas Laboratory:

Precise quality control for Blood Gas Analyzers and temperature deviations

• Research:

Determine influence of sample temperature on Blood Gas Parameters and Blood-Glucose

*) The minimum tonometry temperatur depends on ambient parameters (dew point formation)

Page 3: The new reality in Blood Gas QC Tonometry at real sample … · 2019. 1. 10. · Tonometry at real sample temperature…. The new generation of the TM8000 offers active temperature

The features known from the TM8000 are extended once more:

Precision

Stable temperature

control in a wide

range from 20,0°C

to 39,9°C )*

Effective rotation

control for optimal

equilibration.

Secure gas con-

nection and simple

monitoring of the

required gas flow

Operation

Easy sample

preparation

Easy and safe

sampling

Safe cleaning and

decontamination

process

Transpararent water

bath, visible sample

container

Savings

Cost and time saving

operation Th

Fast and precise

equilibration by

thin-film method

Low operating costs

Professional & high

reliability laboratory

device

Page 4: The new reality in Blood Gas QC Tonometry at real sample … · 2019. 1. 10. · Tonometry at real sample temperature…. The new generation of the TM8000 offers active temperature

Technical Data:

• Power Supply: 100 - 240VAC / 50 - 60Hz

• Power Consumption: max. 250VA

• Protection Class: I

• Temperature Control /Stability: 37,0°C ± 0,1°C[98,6°F ± 0,1°F]

• Setting Range: 20,0°C to 39,9°C [68,0°F to 103,8°F]

(limited on dew point formation)

Heatup time: max. 20 minutes

Cool down down time: max. 30 minutes

(depending on ambient temperature)

• Tonometry time: typically 20 minutes

• Sample volume: max. 8ml

• Gas connection: Stainless steel - Quickfit Connector, 4mm

• Required gas flow: 3,5 - 4,5 l/h

• Ambient temperature: 15°C - 30°C [59°F - 86°F]

• Dimensions: DxWxH: 410mm x 330mm x 270mm

• Weight: 19kg

MEON Medical Solutions GmbH & CoKG

8010 Graz, Neue Stiftingtalstrasse 2, AUSTRIA T| +43 316 337 007 -0 E| [email protected]

Sales & Logistics:

Medical Solutions List GmbH, 8010 Graz, Neue Stiftingtalstrasse 2, AUSTRIA

T| +43 316 318685-12 E| [email protected]

Optional „High Performance Gas Mixing Unit“

By using the MEON HP-GMS O2/CO2

gas concentrations from 1,0 - 99,0 %

easily can be preselected (984 000

variations) to enable the Tonometer´s

maximum performance.