Product Specifications The Thermo Scientific Multi-Stream Analyzer (MSA) provides accurate, fast, cost-effective elemental analysis of up to 12 slurry streams. The information provided by the MSA allows plant operators to follow process trends in real time, making manual or automatic changes to the process possible. This analyzer enables improvements in product quality and metal recovery. Thermo Scientific Multi-Stream Analyzer (MSA) XRF Elemental Slurry Analyzer with Environmentally Hardened Cross Cut Sampler The Thermo Scientific Multi-Stream Analyzer (MSA) provides simultaneous analysis of up to 20 elements and percent solids. Elements in the periodic table from Ca and higher can be analyzed using the X-ray Fluorescence (XRF) technique, which is a proven and robust technology for plant environments. The MSA can measure from 3 to 12 streams. Each stream is completely separate in its own analysis tank. The probe moves from zone to zone. This overall design philosophy provides the following benefits: No additional multiplexer or de-multiplexer is required. Low slurry head loss of less than 1 m across the MSA, which combined with a sensible location, dramatically reduces the need for sample delivery or return pumps. The analysis tanks consist of a de-aeration zone, followed by an analysis zone. The standard 300-mm wide analysis tank can accept flows up to approximately 12 m 3 /hr. Larger width tanks are available, which means flows up to 30 m 3 /hr can be analyzed, eliminating the need for primary samplers and providing enhanced sampler accuracy. Assay updates are fast (seven minutes total cycle for six streams). The environmentally hardened cross cut metallurgical samplers are located at the outlet of each analysis tank for calibration and process control samples. When used with full flow or a representative primary sampler (e.g., the Thermo Scientific SamStat), the MSA can collect shift composite samples for metallurgical accounting, providing project cost savings. Flotation Circuit Monitoring Tailings losses Concentrate grades Key impurity levels Head grade variations Optimizes Reagent dosage Flotation air Water balanced flows Feed tonnage Measures and Reports Up to twenty elements (Ca and higher) simultaneously and percent solids Up to 12 streams Period averages: rolling, hourly, shift, day Trends and historical data logging Metal recoveries

Upload: amirthmech

Post on 20-Jul-2016

61 views

Category:

Documents


0 download

DESCRIPTION

eq

TRANSCRIPT

Page 1: Thermo Scientific MSA

Product SpecificationsThe Thermo Scientific Multi-Stream

Analyzer (MSA) provides accurate, fast,

cost-effective elemental analysis of up

to 12 slurry streams. The information

provided by the MSA allows plant

operators to follow process trends in

real time, making manual or automatic

changes to the process possible.

This analyzer enables improvements

in product quality and metal recovery.

Thermo Scientific Multi-Stream Analyzer (MSA)XRF Elemental Slurry Analyzer withEnvironmentally Hardened Cross Cut Sampler

The Thermo Scientific Multi-Stream Analyzer(MSA) provides simultaneous analysis of upto 20 elements and percent solids. Elementsin the periodic table from Ca and higher canbe analyzed using the X-ray Fluorescence(XRF) technique, which is a proven androbust technology for plant environments. The MSA can measure from 3 to 12

streams. Each stream is completely separatein its own analysis tank. The probe movesfrom zone to zone. This overall designphilosophy provides the following benefits:• No additional multiplexer or de-multiplexer is required.

• Low slurry head loss of less than 1 macross the MSA, which combined with asensible location, dramatically reduces theneed for sample delivery or return pumps.

• The analysis tanks consist of a de-aerationzone, followed by an analysis zone. The standard 300-mm wide analysis tankcan accept flows up to approximately 12 m3/hr. Larger width tanks are available,which means flows up to 30 m3/hr can be analyzed, eliminating the need for primary samplers and providing enhanced sampler accuracy.

• Assay updates are fast (seven minutestotal cycle for six streams).

• The environmentally hardened cross cutmetallurgical samplers are located at theoutlet of each analysis tank for calibrationand process control samples. When usedwith full flow or a representative primarysampler (e.g., the Thermo ScientificSamStat), the MSA can collect shiftcomposite samples for metallurgicalaccounting, providing project cost savings.

Flotation Circuit Monitoring• Tailings losses• Concentrate grades• Key impurity levels• Head grade variations

Optimizes• Reagent dosage• Flotation air• Water balanced flows• Feed tonnage

Measures and Reports• Up to twenty elements (Ca and higher) simultaneously and percent solids

• Up to 12 streams• Period averages: rolling, hourly, shift, day• Trends and historical data logging• Metal recoveries

Page 2: Thermo Scientific MSA

Specifications

Thermo Scientific Multi-Stream Analyzer (MSA)

Analysis PerformanceNumber of Streams 3-12Analysis Time per Stream Typically 1 minuteSample Flow Rate Nominally 10 m3/hr for standard tank, from 1m3/hr to 30 m3/hrDetection System Si (Li) solid state detector, LN2-cooled. Typical resolution 170-180 eV.Accuracy All elements with atomic number above 20 (i.e., Ca and higher in the periodic table)

Assay Range (% element by weight) Relative Error10.05 to 0.2 4%-6%0.2 to 1.0 3%-5%1 to 10 2%-4%10 to 80 1%-2%1Guide only; dependent on particle size, mineralogy and matrix variations

Utilities RequiredElectrical Power Factory selectable 380/415/440/460 Volts AC ±10%, 3-phase, 48-62 Hz ±2 Hz (3 wire plus earth)

Maximum power consumption: 6-stream, 2.9 kW; 12-stream, 5.6 kW—with standard 250 W stirrer motorsAir Instrument quality air (clean and dry to 0.1 microns with dew point <2°C). Pressure nominally 600 kPa (87psi),

450 kPa to 800 kPa acceptable. Consumption: <50 liters per hour at working pressure. Secondary air filter built in.Water Clean plant water. 300 – 800 kPa at approximately 20 liters per hour, intermittently.Radioisotope Sources X-Ray Source Typical GBq Activity Recommended Working Life (RWL)

Cm-244 1.1-3.7 30-100 mCi 10 yearsPu-238 1.1-3.7 30-100 mCi 10 yearsAm-241 0.04-0.4 3-10 mCi 15 yearsCd-109 0.4-0.8 5-10 mCi 5 yearsFe-55 0.4-0.8 10-20 mCi 5 years

Communications Links External: OPC (TCP/IP); Modbus (TCP/IP) or Modbus serial (EIA RS-232, RS-422, RS-485) (options available)Remote Access One data-quality phone line or VPN internet linkDimensions and Weights Length Width Height Weight

6-stream unit: 4,260 mm 1,430 mm 2,421 mm 2,010 kg9-stream unit: 5,730 mm 1,430 mm 2,421 mm 3,060 kg12-stream unit: 7,110 mm 1,430 mm 2,421 mm 3,960 kg

Multi-Stream Analyzer (MSA)

Australia+61 (0) 8 8208 8200+61 (0) 8 8234 3772 fax

Chile+56 (2) 378-5080+56 (2) 370-1082 fax

China+86 (0) 21 6865 4588+86 (0) 21 6445 7830 fax

Europe+35 8 9 3291 0788+35 8 9 3291 0580

India+91 (20) 464 0600+91 (20) 464 0630 fax

South Africa+27 (0) 11 822 4120+27 (0) 11 822 3982 fax

USA+1 (800) 488-4399+1 (858) 452-9250 fax

www.thermoscientific.com/[email protected]

Chemical Analysis

© 2012 Thermo Fisher Scientific Inc. All rights reserved. Results may vary under different operating conditions. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. Literature Code PI.7011.0512