thermal interface units
TRANSCRIPT
THERMAL INTERFACE UNITS
Designed for performance
Designed and manufactured in the UK
THE BENEFITS ARE ALL IN THE NAME
QUALITY
Every Reliance Worldwide Corporation (UK) Ltd. product is manufactured to the highest standards using pioneering techniques and only the very highest quality materials. Our reputation is built on premium quality and high performance. Knowing this, our customers appreciate the convenience of being able to turn to a single supplier to access a truly comprehensive range of ultra-reliable plumbing and heating products.
Reliance Worldwide Corporation (UK) Ltd. is an accredited manufacturerto the following International Standards.
DEPENDABILITY
From the instant we first started supplying the plumbing market and hot water system manufacturers in 1986, Reliance Worldwide Corporation (UK) Ltd. has been the last word in dependability. We are part of Reliance Worldwide Corporation (Aus) Pty Ltd. who are global specialists dedicated to improving and delivering world-leading pressure, temperature and flow control products.
INNOVATION
Reliance Worldwide Corporation (UK) Ltd. has been, and always will be, at the forefront of innovative and dynamic end-to-end plumbing and heating solutions. With an impressive track record for developing market-leading thermostatic technology in the UK, we owe it all to our customers. By actively listening to and identifying their needs, then developing products to meet and surpass them, we have a formidable reputation for true innovation.
RELIABILITY
Reliance Worldwide Corporation (UK) Ltd. is all about steadfast reliability. Buy Reliance Worldwide Corporation (UK) Ltd. products once, experience genuine reliability and you become a customer for life. We also offer comprehensive warranties as we have such proven faith in the quality, performance and ultimately the reliability of our products.
SIMPLICITY
Cutting edge technology is used to design and create Reliance Worldwide Corporation (UK) Ltd. products, with ease of installation and minimisation of maintenance being a key aim. A high quality reliable product that is simple to install not only satisfies customers, it speeds up fitting time. Anything that can make the installer’s job easier and faster can only have a positive effect on reducing cost.
2
Tel: +44 (0)1386 712 400 Email: [email protected]
Radiance® TIUs from Reliance Worldwide Corporation (UK) Ltd. offer the perfect solution as they can be adapted to exact requirements when an instantaneous or stored hot water system is required in a Community Heating Network installation.As a leading supplier to the UK heating industry for many years, we have gained a wealth of knowledge and experience in the design and production of innovative products. The Reliance Water Controls brand is recognised for quality and reliability and our TIUs, created specifically to suit UK systems, have been designed, manufactured and tested to ensure they provide the same high levels of satisfaction and longevity.
We understand that no two project requirements are the same, that is why we provide a dedicated technical and design support service to work alongside you. This enables us to develop custom-built solutions to meet the exacting needs of your project. We won’t just focus on the TIUs, we will ensure your whole system operates as effectively and efficiently as possible to meet every demand.
Our Radiance TIUs are manufactured in the UK ensuring lead times are minimal and deliveries can be made to suit a site’s requirements.
THERMAL INTERFACE UNITS (TIUs)
CONTENTS
What is a TIU And How Does It Work? 4
High Efficiency Solution for community networks 5
Radiance Range Overview 6
Radiance Features and Benefits 8
Rapid Specification 10
Swift Specification 11
Active Specification 12
Zest Specification 13
Spirit Specification 14
Chill Specification 15
Optional Extras 16
Diversity Charts 18
System Design 21
Conformance and Approvals 21
Guarantee 21
Related Products 22
Designed and manufactured in the UK
3
ENERGY CENTRE
ENERGY CENTRE
Domestic Hot WaterDomestic Hot Water Return FlowMains Water Supply
WHAT IS A TIU AND HOW DOES IT WORK?TIUs form part of a community heating network (CHN) that provides central heating and domestic hot water to individual properties or apartments within a single development.
Traditionally in the UK, housing stocks have been built with individual gas combi boilers located in each apartment. Conversely, across mainland Europe Community Heating Networks - (or District Heating Systems as they were previously known), have long been the solution to provide heating and hot water in large community developments, with a centralised energy centre coupled with a low temperature hot water network.
In recent years we have seen a resurgence of CHN developments in the UK as the available technology improves and becomes
more popular in helping comply with current legislation for energy efficiency and reduced emissions.
Community heating networks operate from a single energy source (the energy centre) that distributes energy in the form of hot water circulating within a primary network throughout a building or housing development. Each individual house or apartment has a secondary network which is connected to the primary network via a thermal interface unit that heats DHW and space heating water via plate heat exchangers to meet the individual demands of the property.
Typical apartment type installation
Typical housing development installation
4
Tel: +44 (0)1386 712 400 Email: [email protected]
HIGH EFFICIENCY SOLUTION FOR COMMUNITY HEATING NETWORKS✔The absence of gas throughout the building avoids the cost of testing/regulations for
installing gas
✔ The absence of flues saves cost and allows for an aesthetically pleasing building exterior
✔ No planning constraints
✔ Simple design; reduced maintenance
✔ Easily integrated with renewable heat sources if desired (CHP, biomass, heat pump, solar)
✔ Ultra-safe well-known technology using only low pressure hot water
✔ Individual metering options available, including automatic meter reading or a prepayment meter
1. Ball Valves
2. Strainers
3. Diverter Valve
4. Plate Heat Exchanger - Heating (under expansion vessel)
5. Circulation Pump
6. Heat Meter
7. Differential Pressure Control Valve
8. Thermostatic Bypass Valve
9. Primary Zone Valve - Heating
10. Patented Spring Loaded Maintenance Free Expansion Vessel
11. Over Pressure Relief Valve with Pressure Gauge
12. Plate Heat Exchanger - DHW
13. Thermostatic Mixing Valve
14. Flow Sensor - DHW
15. Thermostatic Heating Control Valve
16. Wiring Box
17. Product Information Label
18. Insulated Stainless Steel Pipework
7
18
13
8
15
9
12
16
3
561
10
22
11
14
4
17
5
RANGE OVERVIEW
ActiveDescription Instantaneous DHW
Single plate heat exchanger to generate instantaneous domestic hot water only.
ACTIVE TIU
APARTMENT
BUILDING
MA
INS
CO
LD W
ATE
R
PR
IMA
RY
FLO
W
PR
IMA
RY
RE
TUR
N
DHW
TVA
DHW
TVA
Domestic Hot Water
Tenant Valve Assembly
The Radiance® Thermal Interface Units range comprises six base models.
Three instantaneous hot water units, two stored water units and a cooling unit.
Our comprehensive range is designed to suit any project requirements.
A number of optional extras are also available to suit your exact needs. Please see page 16 - 17.
Inst
anta
neo
us H
ot
Wat
er
SwiftDescription Direct heating + instantaneous DHW
Single plate heat exchanger to generate instantaneous DHW with direct heating connections.
SWIFT TIU
APARTMENT
BUILDING
MA
INS
CO
LD W
ATE
R
SF
SR
PR
IMA
RY
FLO
W
PR
IMA
RY
RE
TUR
N
DHW
TVA
RAD RAD
SF
SR
DHW
TVA
Secondary Flow
Secondary Return
Domestic Hot Water
Tenant Valve Assembly
RAPID TIU
APARTMENT
BUILDING
MA
INS
CO
LD W
ATE
R
SF
SF
SR
SR
PR
IMA
RY
FLO
W
PR
IMA
RY
RE
TUR
N
DHW
DHW
TVA
Secondary Flow
Secondary Return
Domestic Hot Water
Tenant Valve AssemblyTVA
RAD RAD
RapidDescription Indirect heating + instantaneous DHW
Twin plate heat exchanger unit to generate instantaneous DHW with indirect heating connections.
6
Tel: +44 (0)1386 712 400 Email: [email protected]
Sto
red
Hot
Wat
er
BUILDING
SPIRIT TIU
STANDARDCYLINDER
DHW
SF
SR
APARTMENT
RADRAD
MA
INS
CO
LD W
ATE
R
PR
IMA
RY
FLO
W
PR
IMA
RY
RE
TUR
N
TVA
SF
SR
DHW
TVA
Secondary Flow
Secondary Return
Domestic Hot Water
Tenant Valve Assembly
SpiritDescription Indirect heating + standard cylinder water storage
Single plate heat exchanger unit to generate indirect heating.
BUILDING
ZEST TIU
PRE PLUMBEDCYLINDER
DHW
SF
SR
APARTMENT
RADRAD
MA
INS
CO
LD W
ATE
R
PR
IMA
RY
FLO
W
PR
IMA
RY
RE
TUR
N
TVA
SF
SR
DHW
TVA
Secondary Flow
Secondary Return
Domestic Hot Water
Tenant Valve Assembly
ZestDescription Indirect heating + pre-plumbed cylinder stored DHW
Single plate heat exchanger unit to generate indirect heating.
Chi
lled
Wat
er
ChillDescription Cooling/Air conditioning
A single plate cooling unit for air conditioning.
BUILDING
CHILL TIU
SR
SF
APARTMENT
FCUFCU
MA
INS
CO
LD W
ATE
R
PR
IMA
RY
RE
TUR
N
PR
IMA
RY
FLO
W
SF
SR
FCU
Secondary Flow
Secondary Return
Fan Coil Unit
7
FEATURES AND BENEFITS:
Designed for high efficiency performance• Designed and manufactured in the UK to be fully compatible with UK heating and hot
water systems
• Highly energy efficient CHN systems are more eco-friendly and economical than alternative heating methods over system lifetime
• Radiance TIUs are ‘Demand Controlled’ so there is only flow through the unit when there is a requirement for heat or DHW, which reduces unnecessary heat loss, lime-scale build-up and supports whole system longevity
• All internal pipe work is manufactured from high quality, flexible, fully insulated corrugated stainless steel pipes which reduce heat loss and permit bespoke configurations to be made with ease
• WRAS approved
Options to suit individual projects• Radiance TIUs can be configured with a number of optional extras to suit any
individual projects requirements. Reliance Worldwide Corporation (UK) Ltd offer a system design support service to help Architects and Specifiers to ensure maximum energy efficiency is achieved for their projects
• Individual metering options include automatic meter reading or a prepayment type meters for minimal disruption to occupants. A meter reading service can also be provided via a partner organisation if required
8
Tel: +44 (0)1386 712 400 Email: [email protected]
Easy to install and commission• The absence of gas or flues increase safety for occupants and reduces
whole system installation costs in terms of both materials and labour time
• Connections are made easy with SharkBite® push-fit ball valve connectors for an even faster installation. Ball valves with female BSP connections are also available if required
• Each unit is delivered fully factory assembled and is 100% leak tested prior to despatch to ensure product performance and reduce commissioning time
• The absence of soldered or brazed joints minimises contamination and leak potential eliminating the requirement for flushing prior to commissioning
Reduced maintenance• All pipe connections are union fittings sealed with washers for reliable joints and
easy maintenance
• Radiance TIUs incorporate a patented spring loaded expansion vessel which delivers a high performance compact size unit with extended product lifetime which is entirely maintenance free
• Each unit is marked with a unique serial number, product code and production date to ensure individual product identifications/traceability for maintenance records
9
Weight 45 (approx.) Kg
Pressure Rating Primary (max) 10 bar
Secondary (max) 3 bar
Cold water mains (min) 2 bar
Cold water mains (max) 4 bar
Temperature Primary (min) 65 °C
Primary (max) 95 °C
Domestic hot water 30-60 °C
Differential Pressure Primary (max) 2.5 bar
Primary (min) 0.5 bar
DPCV Factory set 0.3 bar
Heat Transfer Capacity *Higher kW available
Heating circuit 15 kW
DHW circuit 42 (Std.)* kW
DHW Flow Rate Temp. rise from 10°-50° 15 l/min
Circulation Pump Branded A rated Standard body 130mm(L) with 1½” connections
Pump head 6m
External Connections Primary flow 22mm PF or ¾" FBSP
Primary return 22mm PF or ¾" FBSP
Secondary flow 22mm PF or ¾" FBSP
Secondary return 22mm PF or ¾" FBSP
Boosted cold water 22mm PF or ¾" FBSP
Domestic hot water 22mm PF or ¾" FBSP
Thermostatic Bypass Adjustable 30-60 °C
INTERNAL SYSTEM COMPONENTS
HM
PR SR
BCW
PF SF
DHW
M
M T
TMV
1A
1B 6 7 9
2 1D
1E13
1F14
10118
2 3 5
15
4
12
1C
1. Ball Valve Connections
1A - Primary Flow (PF)1B - Primary Return (PR)1C - Secondary Flow (SF)1D - Secondary Return (SR) 1E - Domestic Hot Water (DHW) 1F - Boosted Cold Water (BCW)
2. Strainers
3. Diverter Valve for DHW
4. Plate Heat Exchanger - heating
5. Circulation Pump Heating System
6. Heat Meter (optional)
7. Differential Pressure Control Valve
8. Thermostatic By-pass Valve (optional)
9. Primary Zone Valve - Heating
10. Patented Spring Loaded Maintenance Free Expansion Vessel
11. Overpressure Relief Valve with Pressure Gauge
12. Plate Heat Exchanger DHW
13. Thermostatic Mixing Valve DHW (optional)
14. Flow Sensor DHW
15. Thermostatic Heating Control Valve (THCV) (optional)
RAPID SPECIFICATIONIndirect Heating and Instantaneous Domestic Hot Water Unit
A
BC
A. 840mmB. 505mmC. 265mm
10
Tel: +44 (0)1386 712 400 Email: [email protected]
Weight 35 (approx.) Kg
Pressure Rating Primary (max) 10 bar
Secondary (max) 10 bar
Cold water mains (min) 2 bar
Cold water mains (max) 4 bar
Temperature Primary (min) 65 °C
Primary (max) 95 °C
Domestic hot water 30-60 °C
Differential Pressure Primary (max) 2.5 bar
Primary (min) 0.5 bar
DPCV Factory set 0.3 bar
Heat Transfer Capacity *Higher kW available
Heating circuit 15 kW
DHW circuit 42 (Std.)* kW
DHW Flow Rate Temp. rise from 10°-50° 15 l/min
External Connections Primary flow 22mm PF or ¾" FBSP
Primary return 22mm PF or ¾" FBSP
Secondary flow 22mm PF or ¾" FBSP
Secondary return 22mm PF or ¾" FBSP
Boosted cold water 22mm PF or ¾" FBSP
Domestic hot water 22mm PF or ¾" FBSP
Thermostatic Bypass Adjustable 30-60 °C
INTERNAL SYSTEM COMPONENTS
1B
3
6
47
8
95
1D
1F10
1E
2
2 1C1A
HM
PR SR
BCW
PF SF
DHW
M
M
TMV
1. Ball Valve Connections
1A - Primary Flow (PF)1B - Primary Return (PR)1C - Secondary Flow (SF)1D - Secondary Return (SR)1E - Domestic Hot Water (DHW)1F - Boosted Cold Water (BCW)
2. Strainers
3. Diverter Valve for DHW
4. Thermostatic By-pass Valve (optional)
5. Heat Meter (optional)
6. Differential Pressure Control Valve
7. Zone Valve Heating
8. Plate Heat Exchanger DHW
9. Thermostatic Mixing Valve DHW (optional)
10. Flow Sensor DHW
SWIFT SPECIFICATIONDirect Heating and Instantaneous Domestic Hot Water Unit
A
BC
A. 840mmB. 505mmC. 265mm
11
ACTIVE SPECIFICATION
INTERNAL SYSTEM COMPONENTS
1B
3
7
8
6 9 1D
2 5 1C1A
HM
PR BCW
PF DHW
M TMV4
1. Ball Valve Connections
1A - Primary Flow (PF)1B - Primary Return (PR)1C - Domestic Hot Water (DHW)1D - Boosted Cold Water(BCW)
2. Strainer
3. Primary Control Valve
4. Plate Heat Exchanger
5. Thermostatic Blending Valve DHW (optional)
6. Heat Meter (optional)
7. Differential Pressure Control Valve
8. Thermostatic By-pass Valve (optional)
9. Flow Sensor DHW
Weight 30 (approx.) Kg
Pressure Rating Primary (max) 10 bar
Cold water mains (min) 2 bar
Cold water mains (max) 4 bar
Temperature Primary (min) 65 °C
Primary (max) 95 °C
Domestic hot water 30-60 °C
Differential Pressure Primary (max) 2.5 bar
Primary (min) 0.5 bar
DPCV Factory set 0.3 bar
Heat Transfer Capacity *Higher kW available
DHW circuit 42 (Std.)* kW
DHW Flow Rate Temp. rise from 10°-50° 15 l/min
External Connections Primary flow 22mm PF or ¾" FBSP
Primary return 22mm PF or ¾" FBSP
Boosted cold water 22mm PF or ¾" FBSP
Domestic hot water 22mm PF or ¾" FBSP
Thermostatic Bypass Adjustable 30-60 °C
Instantaneous Domestic Hot Water Unit
A
BC
A. 840mmB. 505mmC. 265mm
12
Tel: +44 (0)1386 712 400 Email: [email protected]
ZEST SPECIFICATION
1B 6 7 1D
21A
HM
4
5
1C
M T
3
PR SR
PF SF
1. Ball Valve Connections
1A - Primary Flow (PF)1B - Primary Return (PR)1C - Secondary Flow (SF)1D - Secondary Return (SR)
2. Strainer
3. Zone Valve
4. Thermostatic Control Valve (optional)
5. Plate Heat Exchanger
6. Heat Meter (optional)
7. Differential Pressure Control Valve
INTERNAL SYSTEM COMPONENTS
Weight 25 (approx.) Kg
Pressure Rating Primary (max) 10 bar
Secondary (max) 3 bar
Temperature Primary (max) 95 °C
Secondary (max) 90 °C
Differential Pressure Primary (max) 2.5 bar
Primary (Min) 0.5 bar
DPCV Factory Set 0.3 bar
Heat Transfer Capacity (At dt=30k and flow=571l/hr) 20 kW
External Connections Primary flow 22mm PF or ¾" FBSP
Primary return 22mm PF or ¾" FBSP
Secondary flow 22mm PF or ¾" FBSP
Secondary return 22mm PF or ¾" FBSP
Indirect Heating & Domestic Hot Water Unit linked to a Pre-plumbed Cylinder
A
BC
A. 840mmB. 505mmC. 265mm
13
SPIRIT SPECIFICATION
INTERNAL SYSTEM COMPONENTS
1B 6 7 8 9 2
10
1D
2
4
5 1C1A
HM M
PR SR
PF SF
3 T
1. Ball Valve Connections
1A - Primary Flow (PF)1B - Primary Return (PR)1C - Secondary Flow (SF)1D - Secondary Return (SR)
2. Strainers
3. Thermostatic Heating Control Valve (optional)
4. Plate Heat Exchanger
5. Circulation Pump Heating System
6. Heat Meter (optional)
7. Differential Pressure Control Valve
8. Zone Valve Heating
9. Expansion Vessel
10. Overpressure Relief Valve With Pressure Gauge
Weight 35 (approx.) Kg
Pressure Rating Primary (max) 10 bar
Secondary (max) 3 bar
Temperature Primary (min) 65 °C
Primary (max) 95 °C
Differential Pressure Primary (max) 2.5 bar
Primary (min) 0.5 bar
DPCV Factory set 0.3 bar
Heat Transfer Capacity *Higher kW available
Heating circuit 15 kW
Circulation Pump Branded A rated Standard body 130mm(L) with 1½” connections
Pump head 6m
External Connections Primary flow 22mm PF or ¾" FBSP
Primary return 22mm PF or ¾" FBSP
Secondary flow 22mm PF or ¾" FBSP
Secondary return 22mm PF or ¾" FBSP
Thermostatic Heating Control
Adjustable 40-70 °C
Indirect Heating & Domestic Hot Water Unit linked to a Standard Cylinder
A
BC
A. 840mmB. 505mmC. 265mm
14
Tel: +44 (0)1386 712 400 Email: [email protected]
CHILL SPECIFICATION
INTERNAL SYSTEM COMPONENTS
1B 3 5 6 7 2 1D
2 8 1C1A
HM M
PR SR
PF SF4
9
1. Ball Valve Connections
1A - Primary Flow (PF)1B - Primary Return (PR)1C - Secondary Flow (SF)1D - Secondary Return (SR)
2. Strainers
3. Energy Meter (optional)
4. Plate Heat Exchanger
5. Differential Pressure Control Valve
6. Zone Valve Cooling
7. Expansion Vessel
8. Circulation Pump Cooling System
9. Overpressure Relief Valve With Pressure Gauge
Weight 35 (approx.) Kg
Pressure Rating Primary (max) 10 bar
Secondary (max) 3 bar
Temperature Primary (min) 5 °C
Primary (max) 15 °C
Differential Pressure Primary (max) 2.5 bar
Primary (min) 0.6 bar
DPCV Factory set 0.3 bar
Heat Transfer Capacity *Higher kW available
Cooling circuit 4 kW
Circulation Pump Branded A rated Standard body 130mm(L) with 1½” connections
Pump head 6m
External Connections Primary flow 22mm PF or ¾" FBSP
Primary return 22mm PF or ¾" FBSP
Secondary flow 22mm PF or ¾" FBSP
Secondary return 22mm PF or ¾" FBSP
Cooling/Air Conditioning Unit
A
BC
A. 840mmB. 505mmC. 265mm
15
First Fix Rail (FFR)A first fix rail permits phased installation of the unit and is supplied complete with ball valves to allow for pipework to be pre-installed independent of the main TIU. The packaging also includes a handy fixing template to aid the drilling of fixing holes in the correct location.
The pipe work can be flushed and pressure tested, before the unit is installed and connected to the system.
The FFR is available with or without a flushing bypass valve on the primary side.
Radiance® Thermal Interface Units are designed and manufactured to your individual project requirements. We offer a choice of optional extra components which can be included during assembly to meet your exact specification needs. Our in-house engineering department is available for advice on specification, system design and efficiency.
OPTIONAL EXTRAS
Flushing By-Pass ValveAn integrated connection/by-pass valve allows flushing of the network whilst by-passing the thermal interface unit.
Thermostatic Heating Control Valve (THCV)The thermostatic heating control valve offers better control over the secondary flow temperature and keeps the primary return temperature to a minimum which means the network performs at a higher efficiency.
Thermostatic By-Pass Valve (TBPV)The thermostatic by-pass valve ensures that the temperature of the primary flow pipe will not drop below the set point by circulating water through the primary system if necessary. This enables instantaneous DHW to be available quicker than if the system cooled completely. The TBPV will only circulate water when required thus reducing the energy loss of the system.
Thermostatic Mixing Valve (TMV) - DHWThe thermostatic mixing valve controls the temperature of the DHW and limits it to the set temperature reducing scalding risk.
Ball ValvesConnections are made easy with SharkBite push-fit connectors (as standard).
Female BSP connections are also available, if required.
For more information on SharkBite push-fit plumbing solutions please visit www.sharkbiteplumbing.co.uk
16
Tel: +44 (0)1386 712 400 Email: [email protected]
Water MeterA water meter can be installed to accurately measure water consumption of both hot and cold water for billing purposes. It also includes a pulse output to enable reading by the heat meter.
Ultrasonic Heat MeterAn ultrasonic heat meter can be installed within the thermal interface unit to accurately meter energy consumption for billing purposes. The M-Bus interface for remote meter reading is included as standard.
Mechanical Heat MeterA mechanical heat meter can be installed as an alternative to an ultrasonic heat meter to also accurately meter energy consumption for billing purposes. The M-Bus interface for remote meter reading is included as standard.
Cover LockA locking mechanism is available to prevent tampering with the unit settings.
Meter ReadingAn M-Bus master unit is available to automatically read all meters on the M-Bus network.
A wireless radio meter reading device is also available for manual meter reading. This works in conjunction with an android phone or tablet where information will be saved.
Prepayment UnitThe prepayment unit takes the reading from the heat meter and will shut off the TIU when there is no credit left. The unit communicates with a central server via GSM (Global System for Mobile Communications). It is also certified as an ENE3 display.
A partner company is able to offer a full prepayment solution - please contact us for details.
17
0
0,00
0,10
0,20
0,30
0,40
0,50
0,60
0,70
0,80
0,90
1,00
20 40 60 80 100 120 140 160 180 200
Text Book Diversity Factor
Diversity Factor based on measurements taken from a working Heating Network
Diversity Factor based on DIN 4708
Diversity Factor used by other manufacturers
DIVERSITY CHARTSCommunity heating networks show a high diversity on their domestic hot water (DHW) load. The diversity factor depends on how many units are connected to the network and also on the network layout.
The maximum network load can be greatly reduced by including DHW diversity. This allows a reduction in the required pipe size, saving on installation and maintenance cost.
The charts below give the load factors depending on the number of units connected to a branch or network.
18
Tel: +44 (0)1386 712 400 Email: [email protected]
1
1,001,101,201,301,401,501,601,701,801,902,002,102,202,302,402,502,602,702,802,903,003,10
2 3 4 5 6 7 8 9 10 11 12 13 14
Diversity in 1 - 14 Apartments
Num
ber
of c
oncu
rren
tly d
raw
ing
Apa
rtm
ents
Number of Apartments
14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45
2,80
2,90
3,00
3,10
3,20
3,30
3,40
3,50
3,60
3,70
3,80
3,90
Diversity in 14 - 45 Apartments
Num
ber
of c
oncu
rren
tly d
raw
ing
Apa
rtm
ents
Number of Apartments
19
DIVERSITY CHARTS
100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 2005,50
6,00
6,50
7,00
7,50
8,00
8,50
9,00
9,50
Num
ber
of c
oncu
rren
tly d
raw
ing
Apa
rtm
ents
Number of Apartments
Diversity in 100 - 200 Apartments
45 50 55 60 65 70 75 80 85 90 95 1003,603,703,803,904,004,104,204,304,404,504,604,704,804,905,005,105,205,305,405,505,505,705,805,906,006,106,20
Num
ber
of c
oncu
rren
tly d
raw
ing
Apa
rtm
ents
Number of Apartments
Diversity in 45 - 100 Apartments
20
Tel: +44 (0)1386 712 400 Email: [email protected]
SYSTEM DESIGNReliance Worldwide Corporation (UK) Ltd. offer a system design support service for Architects and Specifiers to consult with UK based engineers who are able to offer advice on effective system design to ensure maximum energy efficiency is achieved. Contact us on the number below.
WARRANTYRadiance Thermal Interface Units (TIUs) are manufactured in the UK from the highest quality components to ensure reliability and maintain longevity. All Radiance TIUs are supplied fully assembled and leak tested with a 2 year warranty* as standard.
*subject to terms and conditions which can be found at www.rwc.co.uk
CONFORMANCE AND APPROVALSConforms to Building regulations part L (2010)
21
Heating ControlsReliance Water Controls Touchscreen Programmable Thermostats provide precise temperature control within +/- 1°C and are available in a stylish white or black gloss case to suit any interior decor. The thermostats incorporate an easy to read digital LED display, with seven day programming, with up to six events per day.
For further information on any of the products above or to view the full Reliance Worldwide Corporation (UK) Ltd. range, please visit www.rwc.co.uk
Tenant® Valves Reliance Water Control Tenant Valves are an innovative, compact, 5-in-1 solution for the control and monitoring of incoming water supplies. Ideal for multi-occupancy buildings with several service provisions. Includes PRV, Pressure Gauge, Isolating Valve, Double Check Valve and Water Meter Port. Easy to service and maintain with its cartridge design construction. Significantly reduces leak potential. Saves labour time, cost and saves space. Supplied pre-insulated.
Heat PackThe Reliance Water Controls Heat Pack is a useful all in one domestic heating system kit that contains all the common components required on a domestic heating system, including 2 x 22mm Zone Valves, a Wiring Centre, a Two Channel Programmer, a Contact Thermostat and an Electronic Room Thermostat. Components are also available to purchase individually.
SharkBite® Fittings, Valves and PipeSharkBite is the world’s most versatile range of metal push-fit fittings and valves for joining Copper, SharkBite PEX, Carbon Steel and Polybutylene pipes, in any configuration.
With no solder, flux or heat required, SharkBite is ideal for applications where flamed jointing is not permitted. All fittings are manufactured from an ultra-low lead DZR brass and are electrically continuous (when used with metal pipe).
They are also easily detectable behind stud walls in the event of future works. SharkBite fittings are rated up to 120°C at 10 bar so are ideal to use to connect right up to the TIU.
All SharkBite fitting and valves are fully demountable (using a special tool) and are instantly reusable saving additional expense.
RELATED PRODUCTS
22
Tel: +44 (0)1386 712 400 Email: [email protected]
Water Meters Reliance Water Controls offer a comprehensive range of silent operation single and multi-jet, water meters for either hot or cold applications.
The compact design permits both vertical or horizontal installation. All models incorporate a fully rotational dry dial enabling easy reading of the meter regardless of installation position.
Harron Valves The Harron Valve, a combined Thermal Balancing and Pressure Reducing Valve is the latest time saving innovation from Reliance Water Controls. This compact, two in one solution, reduces leak potential and the possibility of installation error. It is supplied complete with its own bespoke insulation case further saving time and cost.
It is suitable for hot water applications and incorporates a built-in disinfection function to protect against legionella, a dry-fit thermometer, easy to read pressure indicator dial, integral strainer and SharkBite® connectors for even quicker installation.
A version is also available with MBSP union connections which permit ease of servicing.
Pressure Reducing Valves (PRVs)Reliance Water Controls offer a comprehensive range of drop tight Pressure Reducing Valves suitable for both domestic and commercial, hot and cold water applications. All products in the range utilise a single piece cartridge design, which permits easy maintenance and can be installed in any orientation.
Thermal Balancing ValvesReliance Water Controls Thermal Balancing Valves automatically balance and maintain optimum temperatures in potable hot water systems and are supplied complete with their own unique moulded insulation.
Fully adjustable with a tamper-proof cap and designed to incorporate a host of benefits including a built-in disinfection function to protect against legionella and a dry-fit push in thermometer which means there is no need to drain down the system for installation.
Reliance Thermal Balancing Valves are also available with SharkBite connectors for even quicker installation.
23
FOR FURTHER INFORMATION OR TO MAKE A PROJECT ENQUIRY, PLEASE CONTACT US:
Reliance Worldwide Corporation (UK) Ltd
Worcester Road, Evesham
Worcestershire WR11 4RA
Tel: +44 (0)1386 712 400
Fax: +44 (0)1386 712 401
Email: [email protected]
www.rwc.co.uk
@RWCUK
facebook.com/reliancewatercontrols
ISSUE 1-06/15
In the interests of continuous product improvement Reliance Worldwide Corporation (UK) Ltd. reserve the right to alter specifications as necessary. E&OE. Copyright ©2015 Reliance Worldwide Corporation (UK) Ltd. Copyright ©2014 Radiance. All trademarks and registered trademarks are the property of Reliance Worldwide Corporation (UK) Ltd. All rights reserved.