the sr scale remover for cooling water treatment without chemicals
TRANSCRIPT
The SR Scale RemoverFor Cooling Water Treatment
Without Chemicals
The problemThe problem
Due to evaporation, concentration of salts in the cooling tower water increases constantly.
This is the main reason for the deposition of scale on the elements of the cooling tower and on the piping.
Above process causes a diminuation of the efficiency of the cooling tower.
Conventional cooling tower Conventional cooling tower water treatmentwater treatment
Mainly by means of addition of chemicals or by water softening.
Both inhibit the deposition of scale but have disadvantages:
- high operating and maintenance costs- large quantities of water used to
maintain conductivity within safe limits- they are ecologically dangerous
Our Solution :Our Solution : the the SRSRIn order to overcome the disadvantages of conventional cooling water treatment we have developed a totally new concept in this field: SR scale remover based on electrolysis.
Our Solution : the Our Solution : the SRSR
The main advantages of the new method:
• The electrical scale remover SR prevents any scale deposits on the elements of the cooling tower
• The electrical scale remover SR reduces water blow down and total water consumption to 50% of conventional consumption.
• The electrical scale remover SR almost totally excludes maintenance costs. ……
Our Solution : the Our Solution : the SRSR The electrical scale remover SR is
controlled by a microprocessor based PLC and its valves are electrically activated without the need of compressed air.
The electrical scale remover SR is ecologically safe and environmentally friendly.
The electrical scale remover SR lengthens the life of the cooling tower.
Control Panel
Enclosure
Circulating Pump
Skid
Titanium anode
Cathode
The The DeviceDevice The SR is supplied as a
compact, skid mounted device
The Electric and Control The Electric and Control SystemSystem
Wide range, stabilized electronic power supply. Input: 230VAC Output: 24VDC – 0-15Amp24VDC – 1Amp24VAC – 2Amp
PLC with LCD display and industrial keyboard for operator interface.
Serial port for data transmission to Central Control Room.
Switchgear for the operation of the circulating pump
The Circulation PumpThe Circulation Pump
Centrifugal pump with a 2 or 3 HP motor.
Capacity 12 cu.m/hour. Supplied as part of the
device Circulates both the cooling
water and the make-up water through the scale remover
The The Enclosure Electrolytic chamber
made of cardon steel, coated by a multi-layer baked epoxy.
The AnodeThe Anode
Made of titanium mesh with MMO coating.
Has an operating life of 8-10 years.
The cathodeThe cathode
Made of stainless steel.
Does not release iron ions into the water.
Elecrically isolated from the enclosure
Operation ProcessOperation Process Both the cooling water and the make-up water are
continuously circulated through the device.
The process is parallel and independent from the circuit to the heat exchanger, but it may be combined into it.
Regeneration as all the operations are fully automatic and do not need any intervention by operator.
By means of the keyboard and the LCD display the operator is given the possibility to manually perform some operations and change some parameters.
……
Operation ProcessOperation Process The process is active and full automatic when the SR is connected
to power.
There are different modes of operation: - continuous (24 hours).
- if at least one of connected towers is operated. - according to day/night time and working days/weekend.
All elements of the scale remover can be operated manually for maintenance and check-up purposes.
At predetermined time intervals and/or when concentration of salts surpasses a certain value, the accumulated scale is removed from the cathode and discharged to the sewage piping.
For simulation of the process click here
Mode : Normal operation
Mode : Normal operation
Mode : Regeneration
Installation at an Israeli shopping centerInstallation at an Israeli shopping center
The chemistry of the The chemistry of the processprocess
By applying electrical power between the two electrodes made of special non corrosive metal, an electrochemical reaction is activated. Water from the cooling tower basin is circulated into the electrical scale remover SR. Due to the electrolysis process calcium ions are deposited on the cathode as CaCO3 and water is retuned to the cooling tower with lower calcium concentration. The scale potential in the cooling tower water decreases and kept low as long as the electrical scale remover is in operation. The chemical reaction on ST-ASR cathode is as follow:Ca(HCO3)2+2OH’ CaCO3 + 2H2O + CO3¯²Mg(HCO3)2+2OH’ Mg(OH)2 + 2H2O + CO3¯²Water contains metal ions Ca(HCO3) and Mg(HCO3) and itself is breaking up into OH- and H+ in the presence of electric current, the OH- ions are attracted by the cathode (the positive anode) and this is why the reaction with metallic ions takes place on this electrode (the cathode). ……
The chemistry of the The chemistry of the processprocess
The reaction is an acid – alkali one. The alkali is the OH- and the acid is the Ca(HCO3)2.
The positive ion is scale – CaCO3
On the cathode surface a high alkaline environment is created.This alkaline environment causes the setting of hydroxides and carbonates of low solubility, enhancing formation of less soluble carbonate and hydroxides.
On the anode surface, made of cataylic metal oxides, oxygen and clhlorine gas are evolved, producing disinfecting conditions which act against the growth of microorganisms.Based on the results of periodic testing of the chemical composition of the cooling tower water, the intensity of the electrolysis may be increased or decreased according to the system requirements.
Technical data Technical data
The scale remover is manufactured in following models:
Model Max.Flow rateCu.m/hour
Cooling tower capacity TR
ST- 5 5 180
ST- 10 10 400
ST- 20 20 800
ST- 25 25 1000
……
TechnicalTechnical data data
Power consumption – 2…. 4 kWh depending on model.
Working current – 4….10 Amp.Economy in water consumption –
25…30%
……
TechnicalTechnical data data
Preparations by Customer for installation of SR:
• Outlet and inlet piping to tower d=1.5”-2”• 2”piping to sewage• Power supply 3X400V – 16Amp
Dimensions of the device:• Area: 900X800 mm• Height 1400 mm